t-1 - dimension iv

1
THESE PLANS ARE CONFIDENTIAL PROPERTY OF DUNKIN' BRANDS INC. UNDER RESTRICTED ACCESS. BIDDING DOCUMENTS (FULL PROJECT) 02-14-14 \\GBD4\AutoCad Projects\00-Current Work\G-213585 Dunkin' Donuts_950 Main Avenue\585-5 CDOC - 02 - Good Keep\585_WORKING FILES_State Submittal\PC 352721_585_0_T-1.0_140219.dwg Dunkin Brands 24x36 (2012).ctb NOTE: DRAWINGS ARE NOT TO SCALE IF PLOTTED ON AN "SHEET SIZE" OTHER THAN 36" x 24" T-1.0 02-18-14 ABBREVIATION INDEX GRAPHIC SYMBOLS DUNKIN DESIGN RELEASE ISSUED: APRIL 1, 2013 BIDDING: FEB. 14, 2014 IMAGE TYPE: FRESH BREW - "JAZZ BREW" BUILDING TYPE: FREESTANDING WITH DRIVE-THRU MARKET: HIGH VOLUME DONUT REVIEWED FOR DESIGN CONFORMANCE ONLY INCOMPLETE INFORMATION: Add requested information and resubmit APPROVED AS NOTED: Submit Record Copy for Archives DISAPPROVED AS NOTED: Revise and Resubmit Notes: Construction Manager DUNKIN' BRANDS APPROVED Date: APPROVAL FOR THESE PLANS BY DUNKIN' BRANDS DOES NOT IMPLY THAT DUNKIN' BRANDS HAS REVIEWED THEM FOR CONFORMITY TO APPLICABLE CODES OR REGULATIONS FURN. FURNITURE F.D. F.O. FT. FIN. FL. EXT. EXIST. EQ. ELEC. EQUIP. DWG. EA. EL. D.S. DR. DIM. DN. DISP. DIA. D.F. FLOOR DRAIN FOOT FACE OF FINISH FLOOR EQUIPMENT ELECTRICAL EXISTING EXTERIOR EQUAL DOWN SPOUT ELEVATION DRAWING EACH DOOR DIMENSION DISPENSER DIAMETER DRINKING FOUNTAIN DOWN CONST. DTL. DEPT. CONT. CONC. CM COL. CMU CLOS. CLG. BSMT. BOT. C.T. C.L. BTWN. BM. BLDG. ALT. APPROX. BD. CONC. MASONRY UNIT CONSTRUCTION DEPARTMENT CONCRETE CONTINUOUS DETAIL CONSTRUCTION MGR. COLUMN CEILING CLOSET BASEMENT CERAMIC TILE CENTER LINE BOTTOM BETWEEN APPROXIMATE ALTERNATE BEAM BUILDING BOARD A.F.F. ALUM. A/C A.D. @ & ALUMINUM AIR CONDITIONING ABOVE FINISH FLOOR AREA DRAIN AT AND COMBO DUNKIN'/BASKIN DUNKIN'/TOGO'S TOGO'S/BASKIN D.B.I. DUNKIN' BRANDS INC. C.S. CONSTRUCTION SPECIFICATIONS ON CENTER NOMINAL OVERALL NOT TO SCALE NUMBER OPENING OPTIONAL PROPERTY PLYWOOD PLUMBING PAINTED POLY VINYL CHLORIDE PER SQUARE INCH PER SQUARE FOOT PLASTIC LAMINATE OUTSIDE DIAMETER P.V.C. PTD. P.S.I. PR. PROP. P.S.F. PLYWD. PLUMB. PAIR OPT. PL. P.LAM. O.D. OPNG. PLATE N.T.S. O.C. O.A. NO. NOM. HOLLOW METAL HEADER GYPSUM BOARD HARDWOOD GALVANIZED INTERIOR INSULATION HORIZONTAL LAMINATE KITCHEN LAVATORY MANUFACTURER MAXIMUM MECHANICAL MASONRY MOUNTED MISCELLANEOUS MINIMUM NOT IN CONTRACT INSIDE DIAMETER MASONRY OPENING M.O. MTD. N.I.C. MIN. MISC. MECH. MFR. MTL. MAX. MAS. METAL LAM. LT. LAV. KIT. JT. LIGHT JOINT I.D. INT. INSUL. HGT. HORIZ. HEIGHT GYP. BD. HDWD. H.M. HDR. GALV. GA. GAUGE 108 A B C D 1 A-1 2 A-7 2 A-9 ROOM NAME 108 SECTION NUMBER SHEET NUMBER SECTION DETAIL DETAIL NUMBER SHEET NUMBER DETAIL A DOOR MARK DOOR XXX XX KEY NOTE EQUIPMENT TAG XX-XX FINISHES ROOM FINISH NUMBER ROOM NUMBER 1 COLUMN REFERENCE GRIDS PARTITION TYPE INTERIOR ELEV. INDICATOR ELEV. NUMBER SHEET NUMBER KEY MAP BUILDING DATA ADA STATEMENT I HEREBY CERTIFY TO THE BEST OF MY UNDERSTANDING THAT THE PLANS AND DRAWINGS FOR THIS PROJECT WERE DRAWN IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL LAWS, INCLUDING, BUT NOT LIMITED TO, THE AMERICANS WITH DISABILITIES ACT (THE "ADA"), THE ADA ACCESSIBILITY GUIDELINES AND ANY STATE OR LOCAL ACCESSIBILITY CODES, REGULATIONS, OR STANDARDS Date: DUNKIN BRANDS DATA STACKING (TOTAL # OF VEHICLES) DRIVE THRU TIMER SYSTEM ESCAPE LANE 9 PART OBSTRUCTED ? 4 16 2 Y 21 105.5 SQ' 6.0 SQ' 62.1 SQ' 9.1 SQ' SQ. FOOTAGE WALK IN FREEZER/ COOLER: REMOTE COMPRESSORS REQUIRED DISTANCE FROM COMPRESSOR TO BOX 5 ' JAZZ BREW TOP OF PLATE T.O.P. VINYL WALL COVERING VINYL COMPOSITION BASE VINYL COMPOSITION TILE WELDED WIRE MESH WITH W/ WWM. WT. WD. W/O WP. W.C. WEIGHT WATERPROOFING WATER CLOSET WITHOUT WOOD T.O.SL. T.O.S. V.W.C. V.C.T. VERT. V.C.B. V.I.F. TYP. TRT. VERIFY IN FIELD VERTICAL TOP OF SLAB TOP OF STEEL TREATED TYPICAL SPECIFICATION SPEC. THRU SUSP. STRUCT. TEL. THK. S.S. STL. STD. SQ. STRUCTURAL THROUGH SUSPENDED TELEPHONE THICK STANDARD STAINLESS STEEL SQUARE STEEL RESIL. REQ'D SCHED. S.F. SIM. SHT. SEC. R.O. RM. REV. SIMILAR SQUARE FOOT SCHEDULE SECTION SHEET ROUGH OPENING RESILIENT REQUIRED REVISION ROOM REINF. RAD. REF. R.A. QTY. Q.T. REINFORCING RADIUS DUNKIN' BRANDS REFRIGERATOR QUANTITY QUARRY TILE 1 A-1 A 2 3 INDEX OF DRAWINGS DESIGN CODES ELECTRICAL LIGHTING PLAN PLUMBING DEMOLITION P-1 E-1 EXTERIOR WALL SECTIONS TITLE SHEET/ ARCHITECTURAL DATA SCHEMATIC SITE PLAN AND ADDITIONAL PROJECT INFORMATION REFLECTED CEILING PLAN, SCHEDULES, DETAILS FINISH FLOOR PLAN, SCHEDULE, AND DETAILS ROOF PLAN/ ROOF DETAILS TYPICAL EXTERIOR WALL SECTIONS A-2 A-5 A-3 A-4 A-10 A-7 A-9 A-6 SP-1 T-1.0 A-8 POS PLAN AND DETAILS E-2 DUNKIN' DONUTS - FLOOR PLAN, NOTES & PARTITION TYPES A-1.1 DUNKIN' DONUTS - HVAC FLOOR PLAN, NOTES AND SCHEDULES M-1 S-1.0 S1.1 S1.1a FOUNDATION PLAN AND DETAILS, DUMPSTER ENCLOSURE DUNKIN' DONUTS - HVAC ROOF PLAN AND DETAILS M-2 DUNKIN' DONUTS - HOOD DETAILS AND OCCUPIED/UNOCCUPIED PANEL M-3 E-4 E-3 SCHEDULES AND DETAILS PLUMBING WASTE/VENT FLOOR PLAN, GREASE INTERCEPTOR CALC. P-2 MISCELLANEOUS DETAILS A-11 MISCELLANEOUS DETAILS / SCHEDULES / NATIONAL ACCOUNT INFORMATION A-12 EXTERIOR ELEVATIONS AND FINISH SCHEDULE INTERIOR ELEVATIONS / WALL FINISH SCHEDULE INTERIOR ELEVATIONS / WALL FINISH SCHEDULE ELECTRICAL POWER PLAN AND ELEVATIONS PLUMBING WATER SUPPLY FLOOR PLAN P-3 C-1 A-6.1 SIGNAGE, EXTERIOR DESIGN GUIDELINES A-2.1 PLUMBING R. O. SYSTEM P-4 PLUMBING DETAILS P-5 PLUMBING ISOMETRICS, SCHEDULES AND CALCS P-6 D-1 RESPONSIBILITY MATRIX & BUILDING CODE REVIEW (SUMMARY) T-1.1 DESIGN CODES ARE REFERENCED THROUGHOUT THE DRAWINGS AND SPECIFICATION. THE BUILDING CODE INTERPRETATION SUMMARY IS ON T-1.1. ARCHITECT'S SIGNATURE HERE WALK IN FREEZER RETAIL SERVICE AREA STORE DIMENSIONS: SEATING AREA WALK IN REFRIGERATOR AREA STORAGE/REST ROOM/ OFFICE AREA KITCHEN PREP AREA SQ. FOOTAGE HANDICAP ACCESSIBLE REST ROOMS: NUMBER NUMBER OF RESTROOMS REFIG/ FREEZER COMBO AREA TOTAL (NET): PUBLIC ACCESS TO REST ROOMS 340 SQ' 300 SQ' 440 (FOH) / 260 (BOH) 400 SQ' 170 SQ' 90 SQ' 260 SQ' 2,000 SQ' 2 MENU BOARD SIZE (SINGLE, COMBO) CAR LENGTHS FROM MENU TO WINDOW YES/NO DRIVE-THRU: NUMBER OF DRIVE THRU WINDOWS 1 X 5 # OF SEATS # OF BARRIER FREE SEATING UNITS # OF TABLES TOTAL # OF SEATS SEATING: STAND UP COUNTERS FASCIA SIGNAGE: DIMENSIONS PYLON DIRECTIONAL NUMBER FASCIA - DRIVE THRU 2 8'-9" X 9'-11" 1 4'-0" X 1'-6" 5'-7" X 11'-1 1/2" 2'-7" X 1'-2" Y IMAGE TYPE: SINGLE BRAND (DD) Y Y C-2 C-3 EXTERIOR ELEVATIONS AND FINISH SCHEDULE (ALTERNATE DUNKIN' DESIGN - EIFS) A-5ALT DEMOLITION PLAN SITE DETAILS EROSION CONTROL GRADING AND UTILITY PLAN NOT USED - EXISTING STRUCTURAL CONDITIONS, NEW STRUCTURE AND STRUCTURAL DETAILS DESIGN LOADS, MECHANICAL LOCATIONS/LOADS, GENERAL STRUCTURAL NOTES H-1 H-2 H-3 OTHER TENANT AND COMMON SPACE - HVAC GENERAL NOTES OTHER TENANT AND COMMON SPACE - HVAC PLAN OTHER TENANT AND COMMON SPACE - HVAC SCHEDULES OVERALL BUILDING PLAN - "WHITE BOX" A-1.0 NOT USED - 10.7 SQ' PROJECTING 1 (TWO SIDED) 4'-1 1/2" X 2'-7" 1 (TWO SIDED) 3 (TWO SIDED) Y G 32 32 32 SPUR 41 41 TO GREEN BAY PROJECT NORTH S E W DePERE, WI SITE SITEWORK AND SITE DETAILS SP-1.1 K-1 EQUIPMENT PLAN AND SCHEDULE February 14, 2014 Daniel J. Roarty, AIA CODE WISCONSIN IBC 2009 CHANGE OF USE: NONE (BUSINESS) CONSTRUCTION: RENOVATION USE/OCCUPANCY: "B" (RESTAURANT < 50) CONSTRUCTION TYPE: VB STORY - 1 SQUARE FEET: BUILDING = 6,000 SF DUNKIN' DONUTS = 2,200 SF OCCUPANT LOAD: BUILDING = 75 DUNKIN' DONUTS = 40 ELECTRICAL SERVICE: 120/208 V, 3 PH, 800 A OTHER TENANTS: LAUNDROMAT OFFICE COMMON CONFERENCE H-4 OTHER TENANT AND COMMON SPACE - HVAC SPECIFICATION

Upload: others

Post on 23-Oct-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: T-1 - Dimension IV

TH

ES

E P

LA

NS

A

RE

C

ON

FID

EN

TIA

L P

RO

PE

RT

Y O

F

DU

NK

IN

' B

RA

ND

S IN

C. U

ND

ER

R

ES

TR

IC

TE

D A

CC

ES

S.

BID

DIN

G D

OC

UM

EN

TS

(F

UL

L P

RO

JE

CT

)

02-14-14

\\G

BD

4\A

uto

Ca

d P

ro

je

cts\0

0-C

urre

nt W

ork\G

-2

13

58

5 D

un

kin

' D

on

uts_

95

0 M

ain

A

ve

nu

e\5

85

-5

C

DO

C - 0

2 - G

oo

d K

ee

p\5

85

_W

OR

KIN

G F

IL

ES

_S

ta

te

S

ub

mitta

l\P

C 3

52

72

1_

58

5_

0_

T-1

.0

_1

40

21

9.d

wg

Du

nkin

B

ra

nd

s 2

4x3

6 (2

01

2).ctb

NO

TE

: D

RA

WIN

GS

A

RE

N

OT

T

O S

CA

LE

IF

P

LO

TT

ED

O

N A

N "S

HE

ET

S

IZ

E" O

TH

ER

T

HA

N 36" x 24"

T-1.002-18-14

ABBREVIATION INDEX

GRAPHIC SYMBOLS

DUNKIN DESIGN RELEASE

ISSUED: APRIL 1, 2013 BIDDING: FEB. 14, 2014

IMAGE TYPE: FRESH BREW - "JAZZ BREW"

BUILDING TYPE: FREESTANDING WITH DRIVE-THRU

MARKET: HIGH VOLUME DONUT

REVIEWED FOR DESIGN CONFORMANCE ONLY

INCOMPLETE INFORMATION: Add requested information and resubmit

APPROVED AS NOTED: Submit Record Copy for Archives

DISAPPROVED AS NOTED: Revise and Resubmit

Notes:

Construction Manager

DUNKIN' BRANDS

APPROVED

Date:

APPROVAL FOR THESE PLANS BY DUNKIN' BRANDS DOES NOT IMPLY THAT DUNKIN' BRANDS HAS REVIEWED THEM FOR CONFORMITY TO APPLICABLE

CODES OR REGULATIONS

FURN. FURNITURE

F.D.

F.O.

FT.

FIN.

FL.

EXT.

EXIST.

EQ.

ELEC.

EQUIP.

DWG.

EA.

EL.

D.S.

DR.

DIM.

DN.

DISP.

DIA.

D.F.

FLOOR DRAIN

FOOT

FACE OF

FINISH

FLOOR

EQUIPMENT

ELECTRICAL

EXISTING

EXTERIOR

EQUAL

DOWN SPOUT

ELEVATION

DRAWING

EACH

DOOR

DIMENSION

DISPENSER

DIAMETER

DRINKING FOUNTAIN

DOWN

CONST.

DTL.

DEPT.

CONT.

CONC.

CM

COL.

CMU

CLOS.

CLG.

BSMT.

BOT.

C.T.

C.L.

BTWN.

BM.

BLDG.

ALT.

APPROX.

BD.

CONC. MASONRY UNIT

CONSTRUCTION

DEPARTMENT

CONCRETE

CONTINUOUS

DETAIL

CONSTRUCTION MGR.

COLUMN

CEILING

CLOSET

BASEMENT

CERAMIC TILE

CENTER LINE

BOTTOM

BETWEEN

APPROXIMATE

ALTERNATE

BEAM

BUILDING

BOARD

A.F.F.

ALUM.

A/C

A.D.

@

&

ALUMINUM

AIR CONDITIONING

ABOVE FINISH FLOOR

AREA DRAIN

AT

AND

COMBO DUNKIN'/BASKIN

DUNKIN'/TOGO'S

TOGO'S/BASKIN

D.B.I. DUNKIN' BRANDS INC.

C.S. CONSTRUCTION

SPECIFICATIONS

ON CENTER

NOMINAL

OVERALL

NOT TO SCALE

NUMBER

OPENING

OPTIONAL

PROPERTY

PLYWOOD

PLUMBING

PAINTED

POLY VINYL CHLORIDE

PER SQUARE INCH

PER SQUARE FOOT

PLASTIC LAMINATE

OUTSIDE DIAMETER

P.V.C.

PTD.

P.S.I.

PR.

PROP.

P.S.F.

PLYWD.

PLUMB.

PAIR

OPT.

PL.

P.LAM.

O.D.

OPNG.

PLATE

N.T.S.

O.C.

O.A.

NO.

NOM.

HOLLOW METAL

HEADER

GYPSUM BOARD

HARDWOOD

GALVANIZED

INTERIOR

INSULATION

HORIZONTAL

LAMINATE

KITCHEN

LAVATORY

MANUFACTURER

MAXIMUM

MECHANICAL

MASONRY

MOUNTED

MISCELLANEOUS

MINIMUM

NOT IN CONTRACT

INSIDE DIAMETER

MASONRY OPENINGM.O.

MTD.

N.I.C.

MIN.

MISC.

MECH.

MFR.

MTL.

MAX.

MAS.

METAL

LAM.

LT.

LAV.

KIT.

JT.

LIGHT

JOINT

I.D.

INT.

INSUL.

HGT.

HORIZ.

HEIGHT

GYP. BD.

HDWD.

H.M.

HDR.

GALV.

GA. GAUGE

108

A

B

C

D

1

A-1

2

A-7

2

A-9

ROOM NAME

108

SECTION NUMBER

SHEET NUMBER

SECTION

DETAIL

DETAIL NUMBER

SHEET NUMBER

DETAIL

A

DOOR MARK

DOOR

XXX

XX

KEY NOTE EQUIPMENT TAG

XX-XX

FINISHES ROOM

FINISH

NUMBER

ROOM

NUMBER

1

COLUMN REFERENCE GRIDS

PARTITION TYPE

INTERIOR ELEV. INDICATOR

ELEV. NUMBER

SHEET NUMBER

KEY MAP

BUILDING DATA

ADA STATEMENT

I HEREBY CERTIFY TO THE BEST OF MY UNDERSTANDING THAT THE PLANS AND DRAWINGS

FOR THIS PROJECT WERE DRAWN IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL

LAWS, INCLUDING, BUT NOT LIMITED TO, THE AMERICANS WITH DISABILITIES ACT (THE "ADA"),

THE ADA ACCESSIBILITY GUIDELINES AND ANY STATE OR LOCAL ACCESSIBILITY CODES,

REGULATIONS, OR STANDARDS

Date:

DUNKIN BRANDS DATA

STACKING (TOTAL # OF VEHICLES)

DRIVE THRU TIMER SYSTEM

ESCAPE LANE

9

PART OBSTRUCTED

?

4

16

2

Y

21

105.5 SQ'

6.0 SQ'

62.1 SQ'

9.1 SQ'

SQ. FOOTAGE

WALK IN FREEZER/ COOLER:

REMOTE COMPRESSORS REQUIRED

DISTANCE FROM COMPRESSOR TO BOX 5 '

JAZZ BREW

TOP OF PLATET.O.P.

VINYL WALL COVERING

VINYL COMPOSITION BASE

VINYL COMPOSITION TILE

WELDED WIRE MESH

WITHW/

WWM.

WT.

WD.

W/O

WP.

W.C.

WEIGHT

WATERPROOFING

WATER CLOSET

WITHOUT

WOOD

T.O.SL.

T.O.S.

V.W.C.

V.C.T.

VERT.

V.C.B.

V.I.F.

TYP.

TRT.

VERIFY IN FIELD

VERTICAL

TOP OF SLAB

TOP OF STEEL

TREATED

TYPICAL

SPECIFICATIONSPEC.

THRU

SUSP.

STRUCT.

TEL.

THK.

S.S.

STL.

STD.

SQ.

STRUCTURAL

THROUGH

SUSPENDED

TELEPHONE

THICK

STANDARD

STAINLESS STEEL

SQUARE

STEEL

RESIL.

REQ'D

SCHED.

S.F.

SIM.

SHT.

SEC.

R.O.

RM.

REV.

SIMILAR

SQUARE FOOT

SCHEDULE

SECTION

SHEET

ROUGH OPENING

RESILIENT

REQUIRED

REVISION

ROOM

REINF.

RAD.

REF.

R.A.

QTY.

Q.T.

REINFORCING

RADIUS

DUNKIN' BRANDS

REFRIGERATOR

QUANTITY

QUARRY TILE

1

A-1

A

2 3

INDEX OF DRAWINGS DESIGN CODES

ELECTRICAL LIGHTING PLAN

PLUMBING DEMOLITIONP-1

E-1

EXTERIOR WALL SECTIONS

TITLE SHEET/ ARCHITECTURAL DATA

SCHEMATIC SITE PLAN AND ADDITIONAL PROJECT INFORMATION

REFLECTED CEILING PLAN, SCHEDULES, DETAILS

FINISH FLOOR PLAN, SCHEDULE, AND DETAILS

ROOF PLAN/ ROOF DETAILS

TYPICAL EXTERIOR WALL SECTIONS

A-2

A-5

A-3

A-4

A-10

A-7

A-9

A-6

SP-1

T-1.0

A-8

POS PLAN AND DETAILS

E-2

DUNKIN' DONUTS - FLOOR PLAN, NOTES & PARTITION TYPESA-1.1

DUNKIN' DONUTS - HVAC FLOOR PLAN, NOTES AND SCHEDULESM-1

S-1.0

S1.1

S1.1a

FOUNDATION PLAN AND DETAILS, DUMPSTER ENCLOSURE

DUNKIN' DONUTS - HVAC ROOF PLAN AND DETAILSM-2

DUNKIN' DONUTS - HOOD DETAILS AND OCCUPIED/UNOCCUPIED PANELM-3

E-4

E-3

SCHEDULES AND DETAILS

PLUMBING WASTE/VENT FLOOR PLAN, GREASE INTERCEPTOR CALC.P-2

MISCELLANEOUS DETAILS

A-11

MISCELLANEOUS DETAILS / SCHEDULES / NATIONAL ACCOUNT INFORMATIONA-12

EXTERIOR ELEVATIONS AND FINISH SCHEDULE

INTERIOR ELEVATIONS / WALL FINISH SCHEDULE

INTERIOR ELEVATIONS / WALL FINISH SCHEDULE

ELECTRICAL POWER PLAN AND ELEVATIONS

PLUMBING WATER SUPPLY FLOOR PLANP-3

C-1

A-6.1SIGNAGE, EXTERIOR DESIGN GUIDELINES

A-2.1

PLUMBING R. O. SYSTEMP-4

PLUMBING DETAILSP-5

PLUMBING ISOMETRICS, SCHEDULES AND CALCSP-6

D-1

RESPONSIBILITY MATRIX & BUILDING CODE REVIEW (SUMMARY)T-1.1

DESIGN CODES ARE REFERENCED

THROUGHOUT THE DRAWINGS AND

SPECIFICATION. THE BUILDING CODE

INTERPRETATION SUMMARY IS ON T-1.1.

ARCHITECT'S SIGNATURE HERE

WALK IN FREEZER

RETAIL SERVICE AREA

STORE DIMENSIONS:

SEATING AREA

WALK IN REFRIGERATOR AREA

STORAGE/REST ROOM/ OFFICE AREA

KITCHEN PREP AREA

SQ. FOOTAGE

HANDICAP ACCESSIBLE

REST ROOMS:

NUMBER

NUMBER OF RESTROOMS

REFIG/ FREEZER COMBO AREA

TOTAL (NET):

PUBLIC ACCESS TO REST ROOMS

340 SQ'

300 SQ'

440 (FOH) / 260 (BOH)

400 SQ'

170 SQ'

90 SQ'

260 SQ'

2,000 SQ'

2

MENU BOARD SIZE (SINGLE, COMBO)

CAR LENGTHS FROM MENU TO WINDOW

YES/NO

DRIVE-THRU:

NUMBER OF DRIVE THRU WINDOWS

1

X

5

# OF SEATS

# OF BARRIER FREE SEATING UNITS

# OF TABLES

TOTAL # OF SEATS

SEATING:

STAND UP COUNTERS

FASCIA

SIGNAGE:

DIMENSIONS

PYLON

DIRECTIONAL

NUMBER

FASCIA - DRIVE THRU

2 8'-9" X 9'-11"

1 4'-0" X 1'-6"

5'-7" X 11'-1 1/2"

2'-7" X 1'-2"

Y

IMAGE TYPE:

SINGLE BRAND (DD)

Y

Y

C-2

C-3

EXTERIOR ELEVATIONS AND FINISH SCHEDULE (ALTERNATE DUNKIN' DESIGN - EIFS)A-5ALT

DEMOLITION PLAN

SITE DETAILS

EROSION CONTROL

GRADING AND UTILITY PLAN

NOT USED -

EXISTING STRUCTURAL CONDITIONS, NEW STRUCTURE AND STRUCTURAL DETAILS

DESIGN LOADS, MECHANICAL LOCATIONS/LOADS, GENERAL STRUCTURAL NOTES

H-1

H-2

H-3

OTHER TENANT AND COMMON SPACE - HVAC GENERAL NOTES

OTHER TENANT AND COMMON SPACE - HVAC PLAN

OTHER TENANT AND COMMON SPACE - HVAC SCHEDULES

OVERALL BUILDING PLAN - "WHITE BOX"A-1.0

NOT USED -

10.7 SQ'PROJECTING 1 (TWO SIDED) 4'-1 1/2" X 2'-7"

1 (TWO SIDED)

3 (TWO SIDED)

Y

G32

32

32SPUR

41

41

TO GREEN BAY

PROJECT

NORTH

S

EW

DePERE, WI

SITE

SITEWORK AND SITE DETAILSSP-1.1

K-1 EQUIPMENT PLAN AND SCHEDULE

February 14, 2014

Daniel J. Roarty, AIA

CODE WISCONSIN IBC 2009

CHANGE OF USE: NONE (BUSINESS)

CONSTRUCTION: RENOVATION

USE/OCCUPANCY: "B" (RESTAURANT < 50)

CONSTRUCTION TYPE: VB

STORY - 1

SQUARE FEET: BUILDING = 6,000 SF

DUNKIN' DONUTS = 2,200 SF

OCCUPANT LOAD: BUILDING = 75

DUNKIN' DONUTS = 40

ELECTRICAL SERVICE: 120/208 V, 3 PH, 800 A

OTHER TENANTS: LAUNDROMAT

OFFICE

COMMON CONFERENCE

H-4OTHER TENANT AND COMMON SPACE - HVAC SPECIFICATION