systems - ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted...

37
SYSTEMS

Upload: lethien

Post on 18-Jun-2018

231 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

SY ST E M S

MOV75984_EPCE02-18 Page 1 8-OCT-02

Page 2: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

C O N T E N T St a b l e o f

Page 3: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

I NTRODUCTIONWho is Daikin? p 4The history of VRV systems p 5

WHAT I S ? p 6

PRODUCT EXPLANATION p 10Possible indoor units using R-407C p 12Possible outdoor units using R-407C p 13Main Features p 14

A Creating maximum comfort p 14B Energy efficient solution p 16C High reliability p 18D Eco friendly p 19E Easy and flexible design p 20F Simple and rapid installationa p 23

PRODUCT FEATU RE S I N DOOR U N ITS U S I NG R -407C p 26Survey indoor units p 27FXYFP 4-way blow ceiling mounted cassette p 28FXYCP 2-way blow ceiling mounted cassette p 30FXK ceiling mounted corner cassette p 32FXYSP concealed ceiling unit p 34FXYBP concealed ceiling unit (small) p 36FXM concealed ceiling unit (large) p 38FUYP 4-way blow ceiling suspended unit p 40FXH ceiling suspended unit p 42FXA/FXYAP wall mounted unit p 44FXL floor standing unit p 46FXN concealed floor standing unit p 46

PRODUCT FEATU RE S OUTDOOR U N ITS U S I NG R -407C p 48Survey outdoor units p 49

features p 50High-tech supporting R-407C VRV Plus systems p 54

Inverter cooling p 56Inverter heat pump p 57

Inverter cooling only / heat pump p 58Heat recovery series p 59

Inverter heat pump series p 60Heat recovery series p 62

PRODUCT FEATU RE S CONTROL SYSTE M S p 64Survey control systems p 65Individual control systems p 66Centralised control systems p 67

p 69p 70

Lon controller p 71p 71

Accessories p 72

NEW

Page 4: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

page4

• Distribution network

Daikin maintains close contact with its markets through ahighly professional network of local distributors. Perceivedas an extension of the company’s “quality chain”, alldistributors are carefully trained in order to maintain highquality sales, installation and after sales service to theircustomers.

• The environment

Daikin has always given due regard to preservation of theenvironment. Dilligent research into matched equipment/refrigerant combinations has given rise to an extensive rangeof hi tech units and systems, fully optimised for use with thezero ozone depleting potential (ODP) refrigerant, R-407C.

• Training

The Daikin training centre in Ostend is unique and themost advanced of its kind in Europe. Both hands on andtheoretical instruction are provided into all aspects ofthe company’s air conditioning equipment and systems

and specially conceived courses are available to suit distributorsand their approved dealers from all over Europe.

• Quality

The application of advanced technologies, combined withcareful selection of bought in components and extensive inhouse testing and field trial procedures ensures unrivalledproduct quality.

• CE

Daikin units comply with the European regulations thatguarantee the safety of the product.

• ISO14001

ISO14001 assures an effective environmental managementsystem in order to help protect human health and theenvironment from the potential impact of our activities,products and services and to assist in maintaining andimproving the quality of the environment.

• ISO9001

Daikin Europe NV is approved by LRQA for its QualityManagement System in accordance with the ISO9001standard. ISO9001 pertains to quality assurance regardingdesign, development, manufacturing as well as to servicesrelated to the product.

Daikin has more than 70 yearsexperience in manufacturingadvanced, high qualityequipment air conditioning forresidential, commercial andindustrial applications.

The Japanese mothercompany DaikinIndustries Ltd. isactively engaged inresearch into a widespectrum of science

and disciplines, from mechanicsand electronics to chemicals andfluorocarbons.

The application of this researchenables Daikin to introducehigh quality, innovative andenvironmentally friendlyproducts into the market.

Since its formationin 1972, DaikinEurope has evolvedfrom a component

assembly plant into the mostadvanced air conditioningmanufacturing complex inEurope. All European standardsregarding production, healthand safety are met in full.

I n t ro d u c t i o nWho i s d a i k i n ?

Page 5: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

The h i s t o r yo f s y s t e ms

NEW

Page 6: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

W h a t i s

Page 7: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

The innovative Hi-VRV selection programme, Daikin’s flagship software package, enables you to exploit the system’spossibilities to the max and guarantees the end user a perfectservice.From now on you can fully plan your Daikin air-conditioningproject on a step-by-step basis without difficulty.

AIR CONDITIONING

VENTILATION CONTROL ANDMANAGEMENT

DAIKINNETWORK SOLUTION

Page 8: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

HeatRecoveryVentilation

heat and humidity areexchanged between supplyand exhaust air, which• brings outdoor air close to

indoor air conditions• recovers energy loss• realises considerable

reduction of air conditioningcapacity

The i n te l l i gen ta i r c o n d i t i o n i n g

Page 9: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

LON controller

Gateway between VRV system and LON BMS

Page 10: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

p r o d u c t

Page 11: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

• Available in both heat recovery and heat pump format.• Up to 32 indoor units can be connected to 1 single refrigerant

circuit.• This line-up from 16HP to 30HP consists of 2 outdoor components,

main and sub unit.

HEAT RECOVERY

• SIMULTANEOUS cooling AND heating operation from one system• Up to 16 indoor units can be operated from a single outdoor unit

in heat recovery format.• A line-up of 8,10 HP models precisely supports applications in

small facilities and minor expansions and renovations.• Heat recovery is achieved by diverting exhaust heat from indoor

units in cooling mode to areas requiring heating.• The BS unit switches the system between cooling and heating

modes.

INVERTER COOLING ONLY / HEAT PUMP

• EITHER cooling OR heating operation from one system• Up to 16 indoor units can be operated from a single outdoor unit

without the need for an additional adapter PCB.• A line-up of 5,8,10 HP models precisely supports applications in

small facilities and minor expansions and renovations.

OZONE FRIENDLY PRODUCTS

Consideration for the evironment in which we live and work, isafforded very high priority by Daikin. The company’s unique positionas the world’s only manufacturer of both air conditioning equipmentand refrigerant chemicals enables it to offer the perfect symbiosis ofhigh technology and environmental protection.Daikin has actively engaged in intensive research into ozone friendlyrefrigerants, resulting in the development of innovative techniquesfor energy efficient systems that reduce CO2 emissions and limitglobal warming.Daikin is able to offer an extensive range of VRV systems, availablein cooling only, heat pump and heat recovery, genuinely optimisedfor use with R-407C and possessing the same quality and performancelevels as our renowned R-22 models.

Page 12: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

page1 2

PP o s s i b l e i n d o o r u n i t su s i n g R -4 07 C

20 25 32 40 50 63 71 80 100 125 200 250

2-way blow ceilingmounted cassette

Ceiling mountedcorner cassette

4-way blow ceilingmounted cassette

Concealed ceiling unit

Concealed ceiling unit (small)

Concealed ceiling unit (large)

4-way blow ceilingsuspended unit

Ceiling suspended unit

Wall mounted unit

Floor standing unit

Concealed floor standing unit

Type

✘ ✘ ✘✘✘ ✘ ✘ ✘✘

✘ ✘ ✘✘✘ ✘ ✘ ✘

✘ ✘✘ ✘

✘ ✘ ✘✘✘ ✘ ✘ ✘✘

✘ ✘

✘✘ ✘ ✘ ✘✘✘ ✘

✘ ✘✘

✘ ✘ ✘

✘ ✘ ✘✘✘ ✘

✘ ✘ ✘✘✘ ✘

✘ ✘ ✘✘✘ ✘

Page 13: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

P✘

Heat recovery

Heat recovery

* connection ratio: sum of capacity index of connected indoor units.

eg. Selected indoor units: FXYCP25 + FXYCP100 + FXM200 + FXYSP40Connection ratio: 25 + 100 + 200 + 40

= 365➞ possible outdoor unit RSXYP24KJ

INDOOR UNIT CAPACITY INDEX

Model 20 25 32 40 50 63 71 80 100 125 200 250

Capacity index 20 25 31.25 40 50 62.5 71 80 100 125 200 250

Capacitysteps

Page 14: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

100%

11%

100%

26%

A . C re a t i n gm a x i m u m c o m fo r t

m a i n

Inverter technology

The linear VRV system makes use of a variable Proportional Integral(PI) control system which uses refrigerant pressure sensors to giveadded control over inverter and ON/OFF control compressors inorder to abbreviate control steps into smaller units to provideprecise control in both small and larger areas.This in turn enables individual control of up to 32 indoor units ofdifferent capacity and type at a ratio of 50~130 % in comparisonwith outdoor units capacity. 5 HP outdoor units use inverter controlcompressors only.

1

18%

15%

100%

Co

mp

ress

or

Cap

acit

y C

on

tro

l

116Hz-30Hz13 Steps

InverterControl

Large SmallLoad

5HP outdoor unit

Co

mp

ress

or

Cap

acit

y C

on

tro

l

116Hz-30Hz+ No.2 Compressor21 Steps

N°2 Compressor100% Operation

N°1CompressorInverter Control

8 HP

10 HP Large SmallLoad

N°1CompressorInverter Control

8, 10HP outdoor unit 30HP outdoor unit

79Hz-29Hz+ No.2 + No.3Compressor29 Steps

Inverter Control79-29Hz - 18 steps

Large SmallLoad

N°1Compr.Inv. Control

N°2Compressor100%Operation

Co

mp

ress

or

Cap

acit

y C

on

tro

l

N°2Compressor100%Operation

N°3Compressor100%Operation

N°1Compr.Inv. Control

N°1Compr.Inv. Control

page

Page 15: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

2

3

Frequency

30 116 30+on 116+on

Cap

acit

y

50%

60%

55%

65%

Page 16: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

1

2

3

4

Page 17: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

5

Daikin indoor units

Hybrid aerofoil fanThin

Thick

Bending wingof rear end

Hybrid aerofoil fan

Operation rangeof outdoortemperature

Standard operation downto -15°C outdoor ambienttemperatureAdvanced PI control of theoutdoor unit enables VRV (Plus)heat recovery and Invertercooling only/heat pump seriesto operate at outdoor ambientsdown to -5°C in cooling modeand down to -15°C in heatingmode.

6

50

40

30

20

10

-5

-10

-15

50

40

30

20

10

-5

-10

-15

Cooling43°CDB

Cooling43°CDB

Heating15.5°CWB

Heating

15.5°CWB

Cooling & Heating

15.5°CWB

-5°CDB

-15°CWB

-5°CDB -15°CWB

Inverter cooling only/heat pump series

Heat recovery series( ) ( )

-15°CWB

Page 18: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

C1

contents of 1 cycle (48 hours)according to DIN50018 (0.21)testing period : 40 cycles

Performed tests :

8

6

4

2

01 2 3 4 5

Cycle

Co

rro

sio

n r

esis

tan

ce

1 2 3 4 5 6 10 20 30 40Cycle

Co

rro

sio

n r

esis

tan

ce

10

9

8

7

6

5

4

3

2

1

0

DAIKIN P.E.

Bare aluminium

DAIKIN P.E.

contents of 1 cycle (7 days):• 24 hours salt spray test

SS DIN 50021• 96 hours humidity cycle test

KFW DIN 50017• 48 hours room temperature

& room humiditytesting period : 5 cycles

Barealuminium

2 Kesternich test (SO2)

1 VDA Wechseltest

Page 19: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

2

3

D1

2

Class 10 R-22 R-407C R-407CK series K series L series

Refrigerant charge 100 % 83 % 71 %

Optimised R-407C design

The coil and PCB settings of R-407C units have been speciallyadapted to enable a rapid changeover from R-22 to R-407Cwithout capacity loss (± 7 %).

3

Page 20: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

E1 ➔

2

3

Efficient use of space

The VRV system allows you to use the available space moreefficiently. Instead of having to incorporate a machine room in toyour building plans, you can use this space for other purposes,such as a garage.

4

Year round cooling and/or heating

• Designed to provide simultaneous year round cooling and/orheating, VRV (Plus) heat recovery systems are modular inconcept and are therefore, ideal for use in rooms or zones thatgenerate varying thermal loads according to building orientationor local hot or cold spots.

• It is possible for the same meeting room to give rise to differingthermal loads depending on the time of day, number of occupantspresent, location and usage pattern of lighting and electronicoffice equipment.

• Until the advent of the VRV, a complex 4-pipe fan coil was neededto meet this requirement. The VRV however, is easier to designand install and in its heat recovery format, can conserve energy intwo or more rooms at the same time.

Page 21: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

5

6

( )

Actual pipinglength

Height difference*4

Page 22: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

page2 2

EE . Ea s y andf l e x i b l e d e s i g n

Hi-VRV Selection Programme

A simple to use, Daikin Hi-VRV air conditioning computerisedselection programme, designed for use with Windows 95®, Windows 98®

and WindowsNT® systems, enables consulting engineers, design andbuild contractors, property developers and architects etc. to plan aDaikin air conditioning project on a step by step basis, complete withdetailed drawings, bills of quantities and costs.The programme thus enables VRV air conditioning systems to beengineered precisely and economically (without over-sizing units),thereby ensuring optimum operating cycles and maximum energyefficiency.

Features :

• the Hi-VRV selection programme offers 3 separate modes toaccommodate different design formats according to customerrequirements:

1. Expert mode :once the cooling and heating loads in the different rooms havebeen calculated, the software will select the most appropriatesystem plus an estimate of the power consumption

2. Quick mode :based on calculated system loads, the software will select the mostappropriate system

3. Drawing mode :selecting the indoor and outdoor units from a list enables the userto design a system in no time at all

• autocad and scanned drawings can be used to help draw up afloor plan

• piping diameters can be automatically calculated• indoor and outdoor units, headers and joints etc can be

automatically selected

Windows95®, Windows98® and WindowsNT® are registered trademarks of Microsoft corporation.

7

NEW

Page 23: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

FF. S i m p l e a n d rap i di n s t a l l a t i o n

short installation time

• Thanks to small bore refrigerant pipes and REFNET piping options,the VRV piping system can be installed very easily and quickly.

• Installation of the VRV system can also be implemented floor byfloor, so that sections of the building can be put into use veryquickly, or enabling the air conditioning system to be commissionedand operated in stages, rather than on final completion of theproject.

1

Modular & lightweight

• Modular design enables units to be joined together in rows withan outstanding degree of uniformity.

• The design of the outdoor units (from 5HP to 10HP) is sufficientlycompact to allow them to be taken up to the top of a building ina commercial elevator, overcoming site transportation problem,particularly when outdoor units need to be installed on each floor.

2

No structural reinforcement necessary

Thanks to the lightweight and vibration-free construction of theoutdoor units, floors do not need to be reinforced, reducing theoverall cost of the building.

3

Unified REFNET piping

• The unified Daikin REFNET piping system is especially designedfor simple installation and for use with both R-407C and R-22refrigerants.

• Only 2 or 3 main refrigerant pipes are necessary per system andunlike conventional water based schemes, VRV systems do notrequire strainers, stop valves, 2 and 3 way valves, oil traps, antifreeze treatment or air purging.

• The use of REFNET piping in combination with electronic expansionvalves, results in a dramatic reduction in imbalance in refrigerantflowing between indoor units, despite the small diameter of thepiping.

• REFNET joints and headers (both accessories) can cut down oninstallation work and increase system reliability.

• Compared to regular T-joints, where refrigerant distribution is farfrom optimal, the Daikin REFNET joints have specifically beendesigned to optimise refrigerant flow

4REFNET joint

Attached insulators forREFNET joint

REFNET header

Attached insulatorsfor REFNET header

REFNET joint

T-joint

Page 24: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

F. S i m p l e a n d rap i d

3-way piping connection

VRV Plus Inverter and heat recovery series not only offer thepossibility to run piping from the front, but also from the sideand bottom, thus providing greater freedom of layout.

5➔

The use of a single refrigerantpiping circuit, cuts piping costsby 25 to 30% and pipe shaftspace by almost 70%, therebyreducing installation spacerequirements by a significantmargin (based on Daikincalculations).

Sequential start

Up to 3 outdoor units can beconnected to 1 power supplyand can be turned onsequentially. This allows thenumber of breakers and theircapacities to remain small andsimplifies wiring (for models of10Hp or less).

7

Self diagnosis

Detects malfunctions in major locations of the system and displaysthe type of malfunction and location, which in turn allows servicingand maintenance to be performed more efficiently.

8

reduced piping shaft and costs

6

6 pipes for liquid and gas 2 pipes

AROUND 70% SAVING IN PIPING SHAFTAND ITS SPACE

Page 25: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

9 10

11

13

12

Page 26: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

I N D O O R U N I T Sp r o d u c t f e a t u r e s

Page 27: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette
Page 28: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

Branched Closed

Pipinglocation

4-waydischarge

3-way discharge 2-way discharge

The unit can beinstalled in corners

Page 29: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

FX

YF

P20 25 32 40 50 63 80 100 125FXYFP - KB7V19

BRC1C517BRC7C513WBRC7C512WBYC125KJW1

KAFJ556K80 KAFJ556K160KAFJ557K80 KAFJ557K160KAFJ553K80 KAFJ553K160KAFJ552K80 KAFJ552K160

KDDFJ55K160KAFJ551K160KAFJ55K160HKDDJ55B160FKDDJ55B160KKDDJ55B160KKDDJ55X160KDBHJ55K160KDBJ55K160W

KDJ55B80 KDJ55B160KKSJ55K160

Wired remote controlInfrared remote control Cooling only

Heat pumpDecoration panelHigh efficiency filter 65% *1 Colorimetric methodHigh efficiency filter 90% *1 Colorimetric methodReplacement high eff. filter 65% Colorimetric methodReplacement high eff. filter 90% Colorimetric methodFilter chamber for aboveReplacement long life filter Non woven typeReplacement ultra long life filterFresh air intake kit Chamber type without T-shape and fan

with T-shape and fanwith T-shape, without fan

Direct installation typeAir discharge outlet sealing memberPanel spacerBranch duct chamberChamber connection kit

Page 30: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

page3 0

minimum ceilingheight is 35 cm

600mm

Stylish & compact

• Slim unit can be installed in a ceiling void of only 355mm

• Depth of all units is 600mm : easy installation in false ceilings

• Whisper quiet operation: down to 28dBA

• Long life filter is provided as standard

• Drain-up pump with 600mm lift fitted as standard

• Leaves maximum floor and wall space for furniture anddecorations

• Auto-swing mechanism ensures even room air and temperaturedistribution and prevents ceiling soiling.

Less maintenance

• Maintenance operations can be performed by removing the front panel

• Easy to clean flat suction grille

• Detachable swing flaps

Page 31: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

20 25 32 40 50 63 80 125FXYCP - K7V19

BRC1C517BRC7C67BRC7C62

BYBC32GJW1 BYBC50GJW1 BYBC63GJW1 BYBC125GJW1KAFJ532G36 KAFJ532G56 KAFJ532G80 KAFJ532G160KAFJ533G36 KAFJ533G56 KAFJ533G80 KAFJ533G160KDDFJ53G36 KDDFJ53G56 KDDFJ53G80 KDDFJ53G160KAFJ531G36 KAFJ531G56 KAFJ531G80 KAFJ531G160

Wired remote controlInfrared remote control Cooling only

Heat pumpDecoration panelHigh efficiency filter 65% *1High efficiency filter 90% *1Filter chamber for bottom suctionReplacement long life filter

Note:*1. Filter chamber is required when installing a high efficiency filter

FX

YC

P

20 25 32 40 50 63 80 125FXYCP - K7V19

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWBoutdoor temperature: 35°CDBequivalent refrigerant piping: 8m (horizontal)

• Nominal heating capacities are based on: indoor temperature: 20°CDBoutdoor temperature: 7°CDB, 6°CWBequivalent refrigerant piping: 8m (horizontal)

• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat

page3 1

Nominal cooling capacity kWNominal heating capacity kWPower input Cooling W

Heating WPower supplyDimensions Unit HxWxD mm

Decoration panel HxWxD mmWeight Unit kg

Decoration panel kgCasingColour Decoration panelSound pressure level High dB(A)

Low dB(A)Sound power level dB(A)Air flow rate High m3/h

Low m3/hAir filterTemperature controlPiping connections Liquid Flare mm

Gas Flare mmDrain mm

Sound absorbing thermal insulationSafety devices

2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.02.5 3.2 4.0 5.0 6.3 8.0 10.0 16.077 92 130 161 209 25644 59 97 126 176 223

1~, 50Hz, 230V305x780x600 305x995x600 305x1,180x600 305x1,670x60053x1,030x680 53x1,245x680 53x1,430x680 53x1,920x680

26 31 32 35 47 488 8.5 9.5 12

galvanised steel platewhite (10Y9/0.5)

33 35 35.5 38 40 4528 29 30.5 33 35 3945 50 50 52 54 60

420 540 720 990 1,560 1,980300 390 540 780 1,260 1,500

resin net with mold resistantmicroprocessor thermostat for cooling and heating

Ø 6.4 Ø 9.5 Ø 9.5Ø 12.7 Ø 15.9 Ø 19.1

VP25, external diameter 32, internal diameter 25felt / urethane foam

PC board fuse, fan motor thermal fuse, drain pump fuse

Page 32: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

10ß 10ß

65ß 65ß 40ß40ß

10ß 10ß 30ß30ß

65ß 65ß

1Standard

Note:Set standard to 4-way discharge when shipped.High ceiling types 1 and 2 will be set for remote control operation.

2Draughtprevention

3Ceiling soilingprevention

Frontal discharge

Closed by the decoration panel

Combination

500 mm

Downward discharge

Page 33: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

25 32 40 63FXK - LVE

BRC1C517BRC4C63BRC4C61

BYK45FJW1 BYK71FJW1KPBJ52F56W KPBJ52F80WKAFJ521F56 KAFJ521F80K-HV7AW K-HV9AW

KDBJ52F56W KDBJ52F80WKFDJ52F56 KFDJ52F80

Wired remote controlInfrared remote control Cooling only

Heat pumpDecoration panelPanel spacerReplacement long life filterAir discharge grilleAir discharge blind panelFlexible duct (with shutter)

FX

K

25 32 40 63FXK - LVE

Notes: • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWBoutdoor temperature: 35°CDBequivalent refrigerant piping: 5m (horizontal)

• Nominal heating capacities are based on: indoor temperature: 20°CDBoutdoor temperature: 7°CDB, 6°CWBequivalent refrigerant piping: 5m (horizontal)

• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat• *Data were not available at the time of publication

page3 3

Cooling capacity kWHeating capacity kWPower input Cooling W

Heating WPower supplyDimensions Unit HxWxD mm

Decoration panel HxWxD mmWeight Unit kg

Decoration panel kgMaterial UnitColour Decoration panelSound pressure level - 220V High dB(A)

Low dB(A)Sound power level dB(A)Air flow rate High m3/h

Low m3/hAir filterTemperature controlPiping connections Liquid Flare mm

Gas Flare mmDrain mm

Sound absorbing thermal insulationSafety devices

2.8 3.6 4.5 7.13.2 4.0 5.0 8.0

66 76 10546 56 85

1~, 50Hz, 230V215x1,110x710 215x1,310x71070x1,240x800 70x1,440x800

31 348.5 9.5

galvanised steel platewhite

38 40 4233 34 37* * *

660 780 1,080540 600 900

resin net with mold resistantmicroprocessor thermostat for cooling and heating

Ø 6.4 Ø 9.5Ø 12.7 Ø 15.9

VP25 (external diameter 32, internal diameter 25)foamed polyethylene

PC board fuse, fan motor thermal fuse, drain pump thermal fuse PC board fuse, fan motor thermal protector, drain pump thermal fuse

Page 34: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

page3 4

• High external static pressure facilitates unit use with flexible ductsof varying lengths

• Low sound pressure level - 28dBA. The quiet operation of thismodel is ideal for exclusive stores and offices

• Blends unobtrusively with any interior décor

• When using suction panel,unit requires only 350mmof ceiling space

• Drain-up pump with lift up to625mm fitted as standard

• The air suction direction can be altered from rear to bottomsuction

• The switch box can be reached from the side or from the bottomside of the unit for easy servicing

• Long life filter fitted as standard

625mm

Min.350mm

Page 35: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

FX

YS

P20 25 32 40 50 63 80 100 125FXYSP - KA7V19

BRC1C517, BRC2A51, BRC3A61BRC4C64BRC4C62

BYBS32DJW1 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1KTBJ25K36W KTBJ25K56W KTBJ25K80W KTBJ25K160WKEA25K32VE KEA25K50VE KEA25K63VE KEA25K100VE KEA25K125VE

0.75 1.2 1.4 2.1 2.8KAFJ252L36 KAFJ252L56 KAFJ252L80 KAFJ252L160KAFJ253L36 KAFJ253L56 KAFJ253L80 KAFJ253L160KAJ25L36D KAJ25L56D KAJ25L80D KAJ25L160DKAJ25L36B KAJ25L56B KAJ25L80B KAJ25L160BKSA-25K36 KSA-25K56 KSA-25K80 KSA-25K160KBBJ25K36 KBBJ25K56 KBBJ25K80 KBBJ25K160KDAJ25K36 KDAJ25K56 KDAJ25K71 KDAJ25K140

Wired remote controlInfrared remote control Cooling only

Heat pumpDecoration panelService access panelAuxiliary electric heater *1,3 Model 240V/220V

Capacity kWHigh efficiency filter 65% *2High efficiency filter 90% *2Filter chamber for bottom suctionFilter chamber rear suctionAir suction canvasScreening door/blind boardAir discharge adapter for round duct

Page 36: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

page3 6

NEW

Page 37: SYSTEMS - Ekosal range_1.pdf · 20 25 32 40 50 63 71 80 100 125 200250 2-way blow ceiling mounted cassette Ceiling mounted corner cassette 4-way blow ceiling mounted cassette

20 25FXYBP - K7CV19

BRC1C517, BRC2A51, BRC3A61BRC4C64BRC4C62KRP1B2

Wired remote controlInfrared remote control Cooling only

Heat pumpWiring adapter for electric heater *1

Note:*1. Fixing box: KRP1A90

FX

YB

P

20 25FXYBP - KC7V19

Notes : • Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWBoutdoor temperature: 35°CDBequivalent refrigerant piping: 8m (horizontal)

• Nominal heating capacities are based on: indoor air temperature: 20°CDBoutdoor temperature: 7°CDB, 6°CWBequivalent refrigerant piping: 8m (horizontal)

• Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

page3 7

Nominal cooling capacity kWNominal heating capacity kWPower input Cooling W

Heating WPower supplyDimensions HxWxD mmWeight kgCasingSound pressure level High dB(A)

Low dB(A)Sound power level dB(A)Air flow rate High m3/h

Low m3/hAir filterTemperature controlPiping connections Liquid Flare mm

Gas Flare mmDrain mm

Safety devices

2.2 2.82.5 3.2

5050

1~, 50Hz, 230V230x652x502

17zinc coated low carbon steel

373250

402 444312 348

resin net with mold resistantmicroprocessor thermostat for cooling and heating

Ø6.35Ø12.7

VP25, external diameter 27.2, internal diameter 21.6PC board fuse