system configuration guide - nec.com gb hdd 7,200rpm [nxxxx-xxx] configuration information...
TRANSCRIPT
Express5800 Servers
System Configuration GuideExpress5800/E110b
Contents:
IntroductionSpecificationExternal viewOutline drawing / ImagesTested operating system listConfiguration diagramSystem configuration steps overviewQuick configuration diagramSystem Configuration
E110b-M servers1. Basic system2. Processor3. Memory4. Internal drive5. Keyboard6. Mouse7. Optical disk drive8. Floppy disk drive9. System management
System Configuration GuideExpress5800/E110b-M
4th Edition, April 2011
Server chassis1. Consolidated PSU2. Server chassis3. Cooling fan box4. Blank Panel5. Cable Management kit6. DC power cableConsolidated PSU1. Consolidated PSU2. Power supply module3. Unit Management
Supplementary Notes
IntroductionThe document contains product and configuration information that enable you to configure your system.
The proper configuration of your system will be configured by following the step to select the components.The section to select the components mostly consists of two part, Then please select configuration firstly and select necessary
4. Internal drive(HDD / SSD) [std. 0 / max. 1]
Integrated SATA controller Standard 3Gb/s SATA
Supported SATA HDD, SATA SSD
NOTE SAS hard drive is not supported in the system.
Internal SAS/SATA cable[K410-XXXXXX]
SATA HDD (2.5-inch, 3Gb/s) XXX GB HDD 7,200rpm [NXXXX-XXX] YYY GB HDD 7,200rpm [NXXXX-XXX]
Configuration information
Selectable peripherals
Sample of section to select component:
4th Edition, April 2011NEC Corporation
• The icons on the configuration chart stand for the supporting OS as showing in the following table. • For the request to use Linux OS, please also refer to the website
http://www.nec.com/global/prod/express/linux/index.html
… Supported by NEC
… Certified by Distributor
2003 : Windows Server 2003 (with SP1 or later)
2003x64 : Windows Server 2003, x64 Edition
2003R2 : Windows Server 2003 R22003
R2x64 : Windows Server 2003 R2, x64 Edition2008 : Windows Server 2008
2008x64 : Windows Server 2008 (x64)2008 R2 : Windows Server 2008 R2 (x64)ESXi4 : VMware ESXi 4SL10 : SUSE Linux Enterprise Server 10
SL10x64 : SUSE Linux Enterprise Server 10(EM64T)
YYY GB HDD 7,200rpm [NXXXX-XXX]
SATA SSD (2.5-inch, 3Gb/s) XX GB SSD [NXXXX-XXX]
About icons:
System Configuration GuideExpress5800/E110b-M
The document contains product and configuration information that enable you to configure your system.
The proper configuration of your system will be configured by following the step to select the components.two part, configuration information, selectable peripherals list.
peripherals.
[std. 0 / max. 1](non hot plug)
SATA HDDSATA SSD
Internal SAS/SATA cableXXXXXX]
information
peripherals list
4th Edition, April 2011 2
The icons on the configuration chart stand for the supporting OS as showing in the following table. For the request to use Linux OS, please also refer to the website http://www.nec.com/global/prod/express/linux/index.html
EL4 : Red Hat Enterprise Linux ES4/AS4
EL4x64: Red Hat Enterprise Linux ES4(EM64T)/AS4(EM64T)
EL5 : Red Hat Enterprise Linux 5/AP5EL5x64 : Red Hat Enterprise Linux 5(EM64T)/AP5(EM64T)
ML4 : MIRACLE LINUX V4.0ML4x64 : MIRACLE LINUX V4.0(EM64T)
AXS3 : Asianux Server 3AXS3x64 : Asianux Server 3(EM64T)
Outline The low-power 1-socket server optimized for high
Features Achieves low power consumption with Intel® Atom Supports one 2.5-inch SATA and SDD Equips EXPRESSSCOPE Engine 2 to enable superior system management
Specification (Express5800/E110b
Hard drive
Capacity (std.)
Capacity (max.)
Hot swap
Memory sparingMemory mirroing
I/O Controller Hub (IOH)
Memory
Capacity (std./max.)Supported MemoryNative Speed (max.)Error detection and correction
ModelProduct Code
Processor
TypeClock SpeedNumber of processors (std./max.)L2 Cache (per core)Core and Thread (per processor)
4th Edition, April 2011NEC Corporation
Note:*1 Arrange an External DVD for maintenance and OS installation*2 Arrange Flash FDD if needed. For intended uses, refer to the Flash FDD Supplementary Notes in this guide.*3 Minimum configuration: 1x 1GB DIMM and no HDD or SSD, Maximum configuration: 2x 2GB DIMM, 1x 500GB HDD*4 Refer to Linux on NEC Express5800 on NEC global site for the latest information.
Expansion
16.7M color: 640x480, 800x600, 1, 024x768, 1, 280x1, 024
Operating: 10 to 40
Red Hat Enterprise Linux 4.8Red Hat Enterprise Linux 5.4
Refer to "Linux on NEC Express5800" on NEC global site
Supportedoperatingsystem
Certified by ISV *4
Tested operating system *4
Temperature, Relative HumidityIncluded Accessories
Weight(min./max.) *3Power consumption (DC12V, Max. config, Idle)Power consumption (DC12V, Max. config, Operating)Power consumption (AC power supply, Operating)
Dimensions (W x D x H)Interface
Type
GraphicsController/Video RAMColor depth and Resolution
StorageHot swap
Controller type and supported RAID levelOptical disk driveFloppy disk driveMedia bay
System Configuration GuideExpress5800/E110b-M
for high density mounting
Achieves low power consumption with Intel® Atom™ Processor N450.
Equips EXPRESSSCOPE Engine 2 to enable superior system management
Specification (Express5800/E110b-M)
Express5800/E110b-MN8100-1635F
Intel® Atom™ Processor N4501.66GHz
1/1512KB1C/2T
Intel® 82801HBM chipset0 GB/2GB (2x 1GB)DDR2-667 SO-DIMM
667MHz----
2.5-inchHDD: SATA 1TB (1x 1TB)2.5-inchSSD: SATA 100GB (1x 100GB)
Not supported
4th Edition, April 2011 3
installation purpose.*2 Arrange Flash FDD if needed. For intended uses, refer to the Flash FDD Supplementary Notes in this guide.*3 Minimum configuration: 1x 1GB DIMM and no HDD or SSD, Maximum configuration: 2x 2GB DIMM, 1x 500GB HDD*4 Refer to Linux on NEC Express5800 on NEC global site for the latest information.
Not supportedSATA 3Gb/s: No RAID feature
External drive (Optional)*1Optional: Flash FDD (1.44MB)*2
--
Integrated in Server Management Controller/32MB16.7M color: 640x480, 800x600, 1, 024x768, 1, 280x1, 024
1x SUV (1x Seial B, 2x USB 2.0, 1x VGA)22.1 x 453.5 x 119.4 mm
0.7kg/1.0kg23.3 W27.0 W
2091VA/2063W (System, max)Operating: 10 to 40°C/Non-Operating: -10 to 55°C, 20 to 80%(non condensation)
Getting started-
Red Hat Enterprise Linux 4.8 or later, Red Hat Enterprise Linux 4.8 (EM64T) or laterRed Hat Enterprise Linux 5.4 or later, Red Hat Enterprise Linux 5.4 (EM64T) or later
Refer to "Linux on NEC Express5800" on NEC global site
Outline The server chassis employing up to 20 E110b-M server
Features Up to 20 E110b-M servers can be installed in 3U height. Supports hot plug replacement for servers Supports hot plug-able redundant fan to enable to replace it without interruption to the system Power supplying from consolidated power supply unit
Specification (Server chassis)
Note:*1 Minimum configuration: No servers and no optional fan box,
box included
40x 1000BASE-T LAN connector (1000BASE-T/100BASE-TX/10BASE-T, RJ-45, 40x Back, 2 port per server)1x Management LAN connector (100BASE-TX/10BASE-T, RJ-45, 1x Back, shared w ith 20 server)
444.0 x 701.5 x 130.0 mm (Excluding inner rail), 466.0 x 724.5 x 130.0 mm (Including inner rail)
Operating: 10 to 40°C/Non-Operating: -10 to 55°C, 20 to 80%(non condensation)EXPRESSBUILDER (NEC ESMPRO Manager, Users guide(PDF)), SUV cable(0.3m),Tool-less slide
Interface
Dimensions(W x D x H)
Number of sever slots
Product nameProduct code
Included Accessories
Power connector
Cooling Fan
Chassis formfactor
Weight(min./max.) *1Power consumption(12VDC, min./max.) *1Power consumption(100VAC, Operating)Temperature , Relative Humidity
4th Edition, April 2011NEC Corporation
Specification (Consolidated PSU Outline
The power supply unit providing electrical power to many
Features Equips high efficient 80 PLUS® Gold power supply Supports up to 4 power module with hot plug and redundant feature Enables to supply electrical power for 80 servers per 1 consolidated power supply Enables to manage the consolidated power supply unit from remote site.
Note:*1 Minimum configuration: 2 power module, Maximum configuration*2 The maximum output per 1 DC connector can not exceed 840
1x Serial(RS-232C, 9-pin mini-Dsub, Port B, 1x Front), 1x VGA (15-pin mini-Dsub, 1x Front)2x USB2.0 (2x Front), 1x Management LAN connector (100BASE-TX/10BASE-T, RJ-45)
Power supply Number of Power moduleRedundant PSU Supported (needed more than 2 power modules, hot plug)
Type
Power connector
Max. output
444.0 x 671.0 x 43.5 mm (Excluding inner rail), 465.6 x 718.0 x 43.5 mm (Including inner rail)
Operating: 10 to 40°C/Non-Operating: -10 to 55°C, 20 to 80%(non condensation)Included Accessories
Input(AC)
Power consumption(100VAC, Operating)
Dimensions(W x D x H)Weight(min./max.) *1Temperature , Relative Humidity
Product nameProduct code
Interface
Cooling Fan
Power connectorChassis formfactor
Output(DC)
System Configuration GuideExpress5800/E110b-M
M server
M servers can be installed in 3U height.
able redundant fan to enable to replace it without interruption to the systemPower supplying from consolidated power supply unit
Specification (Server chassis)
box, Maximum configuration: 20 serves and 2 optional fan
Server chassisN8141-49F
2040x 1000BASE-T LAN connector (1000BASE-T/100BASE-TX/10BASE-T, RJ-45, 40x Back, 2 port per server)
1x Management LAN connector (100BASE-TX/10BASE-T, RJ-45, 1x Back, shared w ith 20 server)Redundant Fan supported, Hot plug
Up to 10 servers: standard / 11 to 20 servers : optional1x Propriety 12VDC connector
3U rackmount444.0 x 701.5 x 130.0 mm (Excluding inner rail), 466.0 x 724.5 x 130.0 mm (Including inner rail)
22kg / 42kg52W / 610W
2091VA / 2063WOperating: 10 to 40°C/Non-Operating: -10 to 55°C, 20 to 80%(non condensation)
EXPRESSBUILDER (NEC ESMPRO Manager, Users guide(PDF)), SUV cable(0.3m),Tool-less slide rail kit
4th Edition, April 2011 4
Consolidated PSU)
providing electrical power to many servers.
high efficient 80 PLUS® Gold power supply module.redundant feature
Enables to supply electrical power for 80 servers per 1 consolidated power supply unitEnables to manage the consolidated power supply unit from remote site.
configuration: 4 power module840W.
Power bayN8142-36F
1x Serial(RS-232C, 9-pin mini-Dsub, Port B, 1x Front), 1x VGA (15-pin mini-Dsub, 1x Front)2x USB2.0 (2x Front), 1x Management LAN connector (100BASE-TX/10BASE-T, RJ-45)
Standard : 2 / Max : 4
Supported (needed more than 2 power modules, hot plug)650W 80 PLUS® Gold Power supply (hot plug)
100-240 VAC±10%,50/60Hz±3Hz4x Propriety 12VDC connector
1,700W *22091VA / 2063W
Redundant Fan supported, Hot plugUp to 10 servers: standard / 11 to 20 servers : optional
4x Propriety 12VDC connector1U rackmount
444.0 x 671.0 x 43.5 mm (Excluding inner rail), 465.6 x 718.0 x 43.5 mm (Including inner rail)13kg / 15kg
Operating: 10 to 40°C/Non-Operating: -10 to 55°C, 20 to 80%(non condensation)Getting started,Tool-less slide rail kit
External view (Express5800/E110bFront view
Power On/ Standby switch
DUMP(NMI) switch
UID(Unit ID) switch
SUV connector
4th Edition, April 2011NEC Corporation
Pull-out tab
System Configuration GuideExpress5800/E110b-M
(Express5800/E110b-M)
Power LED
Status LED
HDD access LED
UID(Unit ID) LED
4th Edition, April 2011 5
Lever
External view (Server chassis)Front view
Server slots
Rear view
Fax box slots
4th Edition, April 2011NEC Corporation
LAN port A for servers
LAN port B for servers
System Configuration GuideExpress5800/E110b-M
External view (Server chassis)
Pull-out tab
Fax box slots
4th Edition, April 2011 6
Management LAN port DC 12V input connector
LAN port A for servers
LAN port B for servers
External view (Consolidated PSU)Front view
Pull-out tab
Serial connector(Port B)
STATUS LEDUID(Unit ID) button
UID(Unit ID)LED
Power button
4th Edition, April 2011NEC Corporation
Rear view
buttonPower LED
Power supply module bay
DC output button
DC output LED
System Configuration GuideExpress5800/E110b-M
External view (Consolidated PSU)
VGAconnector
USB connector
Serial connector(Port B)
Maintenance LEDLED
Maintenance
4th Edition, April 2011 7
Maintenancebutton
UID(Unit ID)LEDUID(Unit ID)
button
ManagementLAN connector
DC outputconnector
Pull-out tab
Outline drawing / Images (E110bOutline drawing
119.
4 m
m
22.1
mm
19.5
mm
Fron
t
4th Edition, April 2011NEC Corporation
Image (Interior view)
System Configuration GuideExpress5800/E110b-M
Outline drawing / Images (E110b-M)
441.2 mm
453.5 mm
Rea
r
4th Edition, April 2011 8
Outline drawing / Images (Server chassis)Outline drawing
701.5 mm
724.5
466.
0 m
m
Fron
t
4th Edition, April 2011NEC Corporation
724.5
130.
0 m
m
Images- Front view
- Rear view
System Configuration GuideExpress5800/E110b-M
Outline drawing / Images (Server chassis)
mm
724.5 mm
444.
0 m
m
Rea
r
4th Edition, April 2011 9
724.5 mm
Outline drawing / Images (Consolidated PSU)Outline drawing
465.
6 m
m
Fron
t
4th Edition, April 2011NEC Corporation
Images- Front view
- Rear view
671.0 mm
718.0 mm
43.5
mm
System Configuration GuideExpress5800/E110b-M
Outline drawing / Images (Consolidated PSU)
444.
0 m
m
Rea
r
4th Edition, April 2011 10
mm
mm
Tested operating system list (as of January 2011)Operating system
Red Hat Enterprise Linux 4.8Red Hat Enterprise Linux 4.8 (EM64T)Red Hat Enterprise Linux 5.5Red Hat Enterprise Linux 5.5 (EM64T)CentOS 4.8 (x86)CentOS 4.8 (x86_64)CentOS 5.5 (x86)CentOS 5.5 (x86_64)Debian GNU/Linux 5.0 (x86)Debian GNU/Linux 5.0 (AMD64)SUSE Linux Enterprise Server 10 SP3 (x86)SUSE Linux Enterprise Server 10 SP3 (x86_64)SUSE Linux Enterprise Server 11 (x86)SUSE Linux Enterprise Server 11 (x86_64)Vine Linux 5.1 (x86)
4th Edition, April 2011NEC Corporation
Vine Linux 5.1 (x86)Vine Linux 5.1 (x86_64)Turbolinux 11 Server SP1 (32-bit)FreeBSD 7.3 (i386)FreeBSD 7.3 (amd64)FreeBSD 8.0 (i386)FreeBSD 8.0 (amd64)Fedora 13 (x86) Fedora 13 (x86_64)
Note:Refer to "Linux on NEC Express5800" on NEC global site for the latest information. http://www.nec.com/global/prod/express/linux/
System Configuration GuideExpress5800/E110b-M
Tested operating system list (as of January 2011)Tested
XXXXXXXXXX
SUSE Linux Enterprise Server 10 SP3 (x86) XSUSE Linux Enterprise Server 10 SP3 (x86_64) X
XSUSE Linux Enterprise Server 11 (x86_64) X
X
4th Edition, April 2011 11
XXXXXXXXX
Refer to "Linux on NEC Express5800" on NEC global site for the latest information.
System configuration steps overview
Server chassis[N8141
Express5800/E110b-M[N8100-1635F]
1. Server 2. Server chassis
Up to 20 servers
Up to 20 Express5800/E110b-M servers can be installed into Up to 240 servers can be installed into one 42U rack frame The power electricity for 80 or less servers can be supplied The number of the server that can be installed in one rack Refer to the server installation guideline in the guide.
Quick configuration diagram
4th Edition, April 2011NEC Corporation
Server slots (max.20)
Proc.(Atom) 2x DIMM
slots1x HDDBay
2.5-inch HD bay2.5-inchSATA HDD2.5-inchSATA SSD
DIMM slots1GB memory(DDR2-667)(max.2GB)
Fan box1 - 10 servers: Standard11 - 20 servers: Optional
Server chassis
Server
Server or Blank panel
System Configuration GuideExpress5800/E110b-M
System configuration steps overview
Server chassis[N8141-49]
Consolidated PSU[N8142-36F]
2. Server chassis 3. Power unit
DC powercable
into one server chassis.frame in the power loading of 6 kVA per rack.
supplied by one Consolidated PSU with 4 power supply modules.rack depends on the system configuration.
Power cords
configuration diagram
4th Edition, April 2011 12
Power supply module
Power supply module
Power supply module
Power supply module
4x DC-outConn.
1x DC-inConn. DC power
cable
Power supplyStd.2, Max.4
: Standard20 servers: Optional
Server chassis
1x Management LAN
40xLAN(*1)
Power unit
*1 2 port / server
System configuration (E110b
Product Code Product NameN8100-1635F Express5800/E110b-M (1C/N450) 1x Atom N450 (1.66GHz, 1 core/2 thread)
no
1. Basic system
EL4 EL4x64 EL5 EL5x64
2. Processor [std. 1]
Intel® Atom™ Processor N450, 1.66GHz, 1 core/ 2 thread
NOTE To connect input devices and optical drive with server, use the
SUV(Serial/USB/Video) cable attached with server chassis.
4th Edition, April 2011NEC Corporation
3. Memory [std. 0 / max. 2]
1GB memory(1x 1GB)
NOTE At least one DIMM is required to order to configure
DDR2-667 (PC2-5300) non-ECC, Unbuffered
4. Internal drive(HDD / SSD) [std. 0 / max. 1]
Integrated SATA controller Standard 3Gb/s SATA
Supported SATA HDD, SATA SSD
NOTE SAS hard drive is not supported in the system.
Internal SAS/SATA cable[K410-223(00)]
SATA HDD (2.5-inch, 3Gb/s) 160GB HDD 7,200rpm [N8150-316] 500GB HDD 7,200rpm [N8150-317] 1TB HDD 7,200prm [N8150-335]SATA SSD (2.5-inch, 3Gb/s) 100GB SSD [N8150-708]
System Configuration GuideExpress5800/E110b-M
System configuration (E110b-M)
Basic Configuration1x Atom N450 (1.66GHz, 1 core/2 thread)no-DIMM, no-HDD
threadStandard
To connect input devices and optical drive with server, use the SUV(Serial/USB/Video) cable attached with server chassis.
SUV cable
2x USB2.01x Serial1x VGA
4th Edition, April 2011 13
[N8102-370]
configure the system.
[std. 0 / max. 1](non hot plug)
SATA HDDSATA SSD
Internal SAS/SATA cable223(00)]
System configuration (E110b
5. Keyboard
104 Keyboard [N8170-25] USB
USB Optical Mouse [N8170-22] USB, 2-button, Optical with wheel
6. Mouse
7. Optical disk drive
External DVD-ROM(USB)
NOTE: Optical drive is required for installation of operating system and system maintenance.
8. Flash FDD (connect to USB port)
4th Edition, April 2011NEC Corporation
8. Flash FDD (connect to USB port) Flash FDD
Capacity:1.44MB
NOTE: FDD is NOT included as standard. Arrange Flash FDD
Supplementary Notes in this guide. Flash FDD [N8160-86] can not be shipped to Taiwan/Korea
System Configuration GuideExpress5800/E110b-M
System configuration (E110b-M)
[N8160-85]
Optical drive is required for installation of operating system and system maintenance.
2003R2x642003R2
EL4 EL4x64 EL5 EL5x64
2008 2008x64 2008 R2
8. Flash FDD (connect to USB port)
4th Edition, April 2011 14
8. Flash FDD (connect to USB port)[N8160-86]
FDD if needed. For intended uses, refer to the Flash FDD
Taiwan/Korea.
System configuration (E110b
9. Server Management (BMC, EXPRESSSCOPE Engine
Remote KVM and Media License License for one server Remote console and remote media are enabled regardless of OS status. Remote console
Displays a graphics console on the web browser of remote terminal (PC/server)Controls keyboard and mouse via the remote terminals' web browser
Remote mediaProvides access to the CD/DVD/FD/Flash memory on the remote terminals (PC/server) as if
the user were accessing the drives locally
EXPRESSSCOPE Engine 2 1x Management LAN (100BASE-TX, 10BASE-T)
Option
Monitoring serverMonitoring temperature /fan/voltage
Collecting hardware event log
Functions The functions are enabled regardless of OS
status and operating condition. (with some exceptions)
4th Edition, April 2011NEC Corporation
Stall monitoring/automatic reboot POST/BIOSStall monitoring
Alerting
HW failure, Boot failure and OS panic(by SNMP,E-Mail via LAN)HW failure, Boot failure and OS panic(via COM port (modem))
Remote console(via LAN)
POST/BIOS setup, DOS utility*2Boot screen, Panic screen *2CUI screen(OS console) *2GUI screen(OS console)
Remote control(via LAN)
Remote reset /power on–off /dump *OS shutdownRemote media (CD/DVD, FD, Flash)(via LAN)CLP (Command Line Protocol, DMTF compliant)Remote control via web browser(via LAN)Remote batchScheduling
Maintenance Remote boot (PXE boot), maintenance utilityOthers Automatic IP address setting via DNS/DHCPRemote Wake Up Wake On LAN, Wake On RingGroup management Monitoring/controlling by the groupIndustry Standard IPMI (version)*1 Linux uses serial console. The standard serial port bus is*2 Available to manage via serial port
NOTE When using H/W remote KVM console function the display For details on OS support and recommended browser
"EXPRESSSCOPE Engine 2 Users Guide”.
System Configuration GuideExpress5800/E110b-M
System configuration (E110b-M)
(BMC, EXPRESSSCOPE Engine 2)
[N8115-03]
Remote console and remote media are enabled regardless of OS status.
Displays a graphics console on the web browser of remote terminal (PC/server)Controls keyboard and mouse via the remote terminals' web browser
Provides access to the CD/DVD/FD/Flash memory on the remote terminals (PC/server) as if the user were accessing the drives locally
Standard
E110b-M
EXPRESSSCOPE
Engine 2(Standard)
EXPRESSSCOPEEngine 2 with
Remote KVM andMedia License
X X
X X
4th Edition, April 2011 15
X X
HW failure, Boot failure and OS panic X X
HW failure, Boot failure and OS panic X X
X XX *1 XX *1 X
- X*2 X X
X XRemote media (CD/DVD, FD, Flash)(via LAN) - XCLP (Command Line Protocol, DMTF compliant) X XRemote control via web browser(via LAN) X X
X XX X
Remote boot (PXE boot), maintenance utility X XAutomatic IP address setting via DNS/DHCP X X
X XX X
2.0 2.0is used when using via LAN.
display is in 65,536 colors with resolution of 1280x1024.browser of Remote terminal, and other functions, refer to the
System configuration (Server chassis)
Product Code Product NameN8141-49F Server chassis 2 power
2 cooling1 SUV cableNo DC power
1. Server chassis
2. Cooling fan box[std. 1 / max. 2] Additional FAN Box
3. Blank panel
Blank Panel NOTE
No blank panel is included in server chassis. Please be sure to order blank panels of the number of
NOTE The fan boxes for cooling 10 E110b-M servers are installed 1 additional FAN box need to be ordered if more than 11 Supports hot plug feature and redundant configuration
4th Edition, April 2011NEC Corporation
Please be sure to order blank panels of the number of
4. Cable Management Kit
Cable Management Kit for rear (600mm/700mm width rack) Cable Management Kt for front (700mm width rack) NOTE
The kit is used for the cable management of LAN cablesto the rear of the server chassis. The kit includes tray and
To order the kit is recommended for suitable cable management The kit to be ordered depends on the width of 19-inch rack
5. DC power cable DC power cable (60cm) DC power cable (90cm)
NOTE The power cable is used for connecting server chassis Please be sure to order the cable of enough length to
System Configuration GuideExpress5800/E110b-M
System configuration (Server chassis)
Basic Configurationpower supply modulescooling fan box as standard for cooling up to 10 serves
cablepower cables, No blank panel
[N8181-75]
[N8141-50]
slots in which the server is not installed.
installed as standard. .11 servers are installed into one chassis. chassis.
4th Edition, April 2011 16
slots in which the server is not installed.
Cable Management Kit for rear (600mm/700mm width rack) [N8141-53][N8141-54]
cables and power cords connectedand guide rail to fix the cables.
management.rack frame.
[K410-213(0A)][K410-213(0B)]
chassis and Consolidated PSU.connect server chassis and Consolidated PSU.
Guide rail Tray
DC power cable
System configuration (Consolidated PSU)
1. Consolidated PSU
ProductCode Product Name
N8142-36F Consolidated PSU Consolidated power supplyEquips high conversion efficiency power supply
Gold, and 2 power supply modules are standard for redundant configuration.(Max.4, hot plug Enables server management from remote site by server management
controller.Equips 4 DC output connectors and up to 4 server chassis can be connected
in 1 server chassis.
2. Power supply modules [std. 2 / max. 4 Power supply module [N8181-76F]
NOTE 2 power supply modules are standard for redundant
installed into 1 Consolidated PSU. Hot plug supported . The number of power supply modules required depends
4th Edition, April 2011NEC Corporation
. The number of power supply modules required dependsthe chassis installed. Refer the table of Total power
System Configuration GuideExpress5800/E110b-M
System configuration (Consolidated PSU)
Description
supply unit(1U)Equips high conversion efficiency power supply certified with 80 PLUS® Gold, and 2 power supply modules are standard for redundant configuration.(Max.4, hot plug supported)Enables server management from remote site by server management
Equips 4 DC output connectors and up to 4 server chassis can be connected
max. 4]76F] Power cord
Std. 2Max.4
redundant configuration. Up to 4 power supply modules can besupported.
depends on the number of the servers and the number of
4th Edition, April 2011 17
depends on the number of the servers and the number ofpower consumption and weight estimation
System configuration (Consolidated PSU)
3. Unit management (BMC, EXPRESSSCOPE Engine 2)
EXPRESSSCOPE Engine 2 1x Management LAN (100BASE-TX, 10BASE-T)
Managing unitMonitoring temperature /fan/voltage/power consumptionCollecting hardware event log
Stall monitoring/automatic reboot POST/BIOS Stall monitoring
Alerting
HW failure, Boot failure(by SNMP,E-Mail via LAN)
HW failure, Boot failure(via COM port (modem))
Remote console(via LAN)
POST/BIOS setup, DOS utility*3Boot screen *3Remote reset /power on–off of manament controller*3
Functions The functions are enabled regardless of operating
condition.
4th Edition, April 2011NEC Corporation
Remote control(via LAN)
Remote reset /power on–off of manament controller*3CLP (Command Line Protocol, DMTF compliant)Remote control via web browser(via LAN)Remote batchScheduling
Maintenance Maintenance utilityOthers Automatic IP address setting via DNS/DHCPGroup management Monitoring/controlling by the groupIndustry Standard IPMI (version)*1 The remote console feature is supported on the management*2 The remote power on feature is for managing the power of
not always power on. To power on the management controllerPSU.
*3 Available to manage via serial port
NOTE Remote KVM and Media License is not supported in EXPRESSSCOPE
Consolidated PSU
Management controller Management
The Consolidated PSU equips as standard feature to monitoring the unit from remote site.
Most functionsmanagement
To powersetting
System Configuration GuideExpress5800/E110b-M
System configuration (Consolidated PSU)
EXPRESSSCOPE Engine 2)
Standard
Consolidated PSU
EXPRESSSCOPE Engine 2(Standard)
Monitoring temperature /fan/voltage/power X
X
X
X
X
X *1X *1
off of manament controller*3 X *2
The functions are enabled regardless of operating
4th Edition, April 2011 18
off of manament controller*3 X *2CLP (Command Line Protocol, DMTF compliant) XRemote control via web browser(via LAN) X
X--
Automatic IP address setting via DNS/DHCP XX
2.0management controller installed in the Consolidated PSU.
of management controller. The management controller needcontroller is required for setting or maintaining the Consolidated
EXPRESSSCOPE Engine 2 of Consolidated PSU.
Management controllerThe Consolidated PSU equips the management controller as standard feature to monitoring the unit from remote site.
functions listed above can be supported if themanagement controller is powered off.
power on the management controller is required foror maintaining the Consolidated PSU.
System configuration (Consolidated PSU)
Total power consumption and weight estimation Please consult our sales representative if another estimation Total weigh indicates a total value of the weight of the following components:
• E110b-M server, Sever chassis(including rail kit), Consolidated PSU(including rail kit), blank panel, management kit(rear) , fan box, power supply modules, power cords, DC power cords
System configuration of E110b-M
AtomN4501GB memory
no-HDD
AtomN4502GB memory
no-HDD
AtomN4501GB memory
Total Weight 49kg 50kgNumber of powerSupply module(std.2/max.4)
2 2
Maximum power consumption
(100 VAC)
W 508W 567WVA 519VA 579VAA 5.2A 5.8A
Total weight and power consumption based on 20 E110b-
System configuration of E110b-M
AtomN4501GB memory
no-HDD
AtomN4502GB memory
no-HDD
AtomN4501GB memory
Total weight and power consumption based on 40 E110b-
4th Edition, April 2011NEC Corporation
System configuration of E110b-M
AtomN4501GB memory
no-HDD
AtomN4502GB memory
no-HDD
AtomN4501GB memory
Number of servers 80 74Total Weight 163kg 161kg
Number of powerSupply module(std.2/max.4)
4 4
Maximum power consumption
(100 VAC)
W 1938W 2041WVA 1978VA 2082VAA 19.8A 20.8A
Number of E110b-M server that can be installed in one Consolidated PSU configuration:
no-HDD no-HDDTotal Weight 88kg 88kg
Number of powerSupply module(std.2/max.4)
3 3
Maximum power consumption
(100 VAC)
W 985W 1104WVA 1005VA 1126VAA 10.1A 11.3A
System Configuration GuideExpress5800/E110b-M
System configuration (Consolidated PSU)
Total power consumption and weight estimationestimation is needed.
Total weigh indicates a total value of the weight of the following components:M server, Sever chassis(including rail kit), Consolidated PSU(including rail kit), blank panel, cable
) , fan box, power supply modules, power cords, DC power cords
AtomN4501GB memory
HDD
AtomN4502GB memory
HDD
AtomN4501GB memory
SSD
AtomN4502GB memory
SSD53kg 53kg 53kg 53kg
2 2 2 2
597W 657W 508W 567W609VA 670VA 519VA 579VA
6.1A 6.7A 5.2A 5.8A
-M servers, 1 server chassis and 1 Consolidated PSU:
AtomN4501GB memory
HDD
AtomN4502GB memory
HDD
AtomN4501GB memory
SSD
AtomN4502GB memory
SSD
-M servers, 2 server chassis and 1 Consolidated PSU:
4th Edition, April 2011 19
AtomN4501GB memory
HDD
AtomN4502GB memory
HDD
AtomN4501GB memory
SSD
AtomN4502GB memory
SSD70 63 80 74
170kg 165kg 179kg 175kg
4 4 4 4
2031W 2050W 1938W 2041W2072VA 2092VA 1978VA 2082VA
20.7A 20.9A 19.8A 20.8A
M server that can be installed in one Consolidated PSU configuration:
HDD HDD SSD SSD96kg 96kg 96kg 96kg
3 3 3 3
1163W 1282W 985W 1104W1187VA 1308VA 1005VA 1126VA
11.9A 13.1A 10.1A 11.3A
Supplementary Notes <General> Hard disk
Measurement units of the hard disk capacity are 1GB=1000compared with same capacity figures based on 1GB=1024
System Clock When stored at a low or high temperature, the system clock may largely deviate from the current time. Use
NTP client service to keep computer clock accurate.
EXPRESSBUILDER EXPRESSBUILDER (DVD media) includes the following:
Server Management Software : NEC ESMPRO Manager (Windows), NEC ESMPRO Agent User’s Guide for server, chassis, and Consolidated PSU
The express setup installation is not supported in the server.
Operating system For details as specifications and connections limited by OS, refer to this guide and hardware list“.
Processor The features of the Intel ® Atom™ processors supported in the server are as follows:
Category Official Name
64 bit Intel® 64 64 bit function
Energyconsumption
Enhanced Intel® SpeedStep® Technology, (Intel® Demand-Base Switching)
Power conservation technology that changes voltage and frequency according to processor load.
4th Edition, April 2011NEC Corporation
Performance Intel® Turbo Boost Technology Technology that boosts processor frequency.
Performance Intel® Hyper-Threading Technology A function that delivers threadon each processor core.
Virtualization Intel® Virtualization Technology Hardware (CPU)technology.
Security Intel® Execute Disable Bit Technology that helps prevent malicious attacks abusing buffer overflow errors.
Legend:X: Supported -: Not supported
System Configuration GuideExpress5800/E110b-M
Supplementary Notes <General>
Measurement units of the hard disk capacity are 1GB=10003B and 1TB=10004B. The capacity is less when compared with same capacity figures based on 1GB=10243B and 1TB=10244B.
When stored at a low or high temperature, the system clock may largely deviate from the current time. Use NTP client service to keep computer clock accurate.
EXPRESSBUILDER (DVD media) includes the following:Server Management Software : NEC ESMPRO Manager (Windows), NEC ESMPRO AgentUser’s Guide for server, chassis, and Consolidated PSU
The express setup installation is not supported in the server.
For details as specifications and connections limited by OS, refer to this guide and hardware list“.
The features of the Intel ® Atom™ processors supported in the server are as follows:
Feature Overview ProcessorAtom N450
64 bit function XPower conservation technology that changes voltage and frequency according to processor load.
X
4th Edition, April 2011 20
Technology that boosts processor frequency. -A function that delivers thread-level parallelism on each processor core. -
Hardware (CPU)-assisted virtualization technology. X
Technology that helps prevent malicious attacks abusing buffer overflow errors. X
Supplementary Notes <Flash FDD>
Flash FDD (N8160-86) overview
USB2.0 compliant FDD emulation feature equipped in the USB Flash drive.
Stick type. FD icon/capacity is printed for easy recognition.
Capacity: 1.44MB (FAT formatted) *Same as one FD(2HD)
Strap hole, Write protect switch.
Flash FDD is an alternative device of FDD using USB flash drive. This device can be used as boot device without additional driver. Also, automatically recognized by OS as a Floppy disk drive after connecting to USB port since this device supports Plug and Play.*1
*1: Support OS only
Intended uses of FDD substituted by Flash
Flash FDD
4th Edition, April 2011NEC Corporation
Intended uses of FDD substituted by Flash Flash FDD can be used instead of FDD
FDD if needed for your system.Intended use Description
Install
Manual installation Installation of Microsoft Windows Server 2003 R2 or previous Windows Server OS
Linux OS installation
Maintenance
BIOS/FW update Off line update of BIOS or some firmware
Express report service registration
Required when the set up of Express Report Service
Backup software When using disaster recovery option of CA ARCserve Backup on Microsoft Windows Server 2008 or later.When additional driver is needed for Backup Exec Intelligent Disaster Recovery option or disaster recovery of
Replacement/repair of Hardware
Backup/restore of HW information (Serial Number, etc.) when replacement or repair of Hardware.
Log collection, etc. System event log/System information collection when offline
System Configuration GuideExpress5800/E110b-M
Supplementary Notes <Flash FDD>
USB2.0 compliant FDD emulation feature
Stick type. FD icon/capacity is printed for easy
Flash FDD is an alternative device of FDD using USB flash drive. This device can be used as boot device without additional driver. Also, automatically recognized by OS as a Floppy disk drive after connecting to USB port since this device supports Plug and
Flash FDD
4th Edition, April 2011 21
Flash FDDFDD for the following uses. Arrange Flash
NotesInstallation of Microsoft Windows Server 2003 R2 or previous Windows Server OS
Create Windows OS OEM-DiskNot required for Windows Server 2008 or laterDepends on the distribution
Off line update of BIOS or some firmware Not required for the current models, because those support update by CD/DVD and online update.
Required when the set up of Express
When using disaster recovery option of CA Backup on Microsoft Windows
Not required on Windows Server 2003/2003 R2
When additional driver is needed for Backup Exec Intelligent Disaster Recovery option or disaster recovery of NetVault.
Not required when there is no additional driver
Backup/restore of HW information (Serial Number, etc.) when replacement or repair
Not required for the current models
System event log/System information When online, ESMPRO tool can collect System Event Log (SEL).
Copyright © NEC Corporation 2010. All rights reserved.• Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States a• Intel and Intel Atom are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries• Linux is a trademark of Linus Torvalds.• Red Hat is a registered trademark of Red Hat, Inc. in the U.S and other countries.• All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders.• Specifications and technical data are subject to change without notice.
NEC Express5800http://www.nec.com/express/
• Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
U.S and other countries.trade names used in this document are trademarks or registered trademarks of their respective holders.