system ce600 - 208.218.54.142208.218.54.142/endotech_pdf/mcm201100_beamersystem_ce600.pdf · the...

8
Designed by Endoscopists, Refined by Nurses & Techs – An Intuitive Endoscopic Electrosurgical Platform

Upload: others

Post on 10-Mar-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SYSTEM CE600 - 208.218.54.142208.218.54.142/EndoTech_PDF/MCM201100_BeamerSystem_CE600.pdf · The Beamer Argon Snare program on the Beamer System CE600 allows easy toggling between

SYSTEM CE600

Designed by Endoscopists, Refined by Nurses & Techs – An Intuitive Endoscopic Electrosurgical Platform

Page 2: SYSTEM CE600 - 208.218.54.142208.218.54.142/EndoTech_PDF/MCM201100_BeamerSystem_CE600.pdf · The Beamer Argon Snare program on the Beamer System CE600 allows easy toggling between

Energizing Therapeutic Endoscopy For Over 20 YearsFrom the 1988 introduction of Argon and through a history of established and trusted brands ConMed has been known for innovation – a trend that continues today with the Beamer® CE600 System.

Beamer – Intelligent, Innovative, and IntuitiveThe Beamer CE200 was specifically designed for endoscopic use and offers multiple therapies from a single platform. Combining sophisticated technology with unrivalled ease of use, the Beamer CE200 assists in the delivery of outstanding clinical results whatever your level of expertise in electrosurgery. Integrating built in intelligence, innovation and an intuitive user interface, Beamer CE200 allows the quick selection of desired clinical effect, and delivers consistent repeatable clinical results.

THE EXPERTS ARE TALKING

“The BEAMER Argon Beam Coagulator provides a consistent and reliable tissue effect. The control panel is easy to set up and to establish personalized power settings and argon flow rates. The ceramic tip probe dramatically reduces tissue sticking. “

– Dr. Douglas Rex, Indiana University Hospital

Page 3: SYSTEM CE600 - 208.218.54.142208.218.54.142/EndoTech_PDF/MCM201100_BeamerSystem_CE600.pdf · The Beamer Argon Snare program on the Beamer System CE600 allows easy toggling between

Features 1. Clear display; focuses on essentials

2. Easy to operate; quick step control

3. ABC® option

4. Irrigation pump option

5. Convenient storage

6. Hands-free double foot-pedal option

1

2

3

4

5

6

Page 4: SYSTEM CE600 - 208.218.54.142208.218.54.142/EndoTech_PDF/MCM201100_BeamerSystem_CE600.pdf · The Beamer Argon Snare program on the Beamer System CE600 allows easy toggling between

With Endo-Mode you have true “cutting-edge” technologyEndo-Mode is a dynamic process controlled cutting mode. It offers pulsed or fractionated currents that provide controlled cutting with varying, adjustable degrees of coagulation.

Intelligence RedefinedAutomatic Cutting Effect Regulation (ACE)

The Beamer® CE200 features Automatic Cutting Effect (ACE) regulation that provides continuous monitoring of sparks around the active electrode and maintains the spark formation required for effective controlled cutting.

Active in all Automatic Modes, ACE monitors and automatically adjusts voltage, spark and power. This results in the delivery of consistent, repeatable endoscopic cutting and hemostatic effects and removes the variability often seen in endoscopic applications of electrosurgery.

ARC Sense V_Sense

P_Control

ACE

Specifically designed for endoscopic applications Endo-Mode features periods of cut, separated by periods of coagulation.

Endo-Mode

Power Power

Time Time

n Polypectomy

n Hot Biopsy

n Sphincterotomy

n BiCap® Hemostasis

n EMR-ESD

G levels permit quick adjustments to the duration or length of the cut and the intensity of the hemostatic effects.

G Levels

G 1G 2

G 3G 4

G 5

Cut

Coag

Page 5: SYSTEM CE600 - 208.218.54.142208.218.54.142/EndoTech_PDF/MCM201100_BeamerSystem_CE600.pdf · The Beamer Argon Snare program on the Beamer System CE600 allows easy toggling between

Argon Beam Coagulation (ABC) with the ConMed Beamer Plus Argon Beam Coagulation (ABC) also called Argon Plasma Coagulation (APC) is a non-contact coagulation method. ConMed ABC technology achieves enhanced clinical effectiveness by focusing radio frequency energy in a directional, non-contact, beam of argon gas. The result is faster hemostasis, a more homogeneous eschar, less tissue damage, and limited penetration depth when compared to conventional coagulation technologies.

Benefits of ABCn Less tissue carbonization

n Reduced procedure time

n Limited penetration depth

n Enhanced clinical effectiveness

Indications for ABCn Hemostasis: Vasular ectasias,

bleeding ulcers, bleeding varices

n Ablation: Barretts esophagus, polyp & remnant adenomatous tissue, debulking malignant tumors

ConMed has been the dependable choice for

Argon Beam Coagulation (ABC®) for the past 2 decades

Argon Steady – Steady beam

Argon Slow – slow beam repetition rate

Argon Fast – fast beam repetition rate

Argon Super – Superfast beam repetition rate

Page 6: SYSTEM CE600 - 208.218.54.142208.218.54.142/EndoTech_PDF/MCM201100_BeamerSystem_CE600.pdf · The Beamer Argon Snare program on the Beamer System CE600 allows easy toggling between

Innovation in the GI SuiteBeamer® Plus Accessories

Beamer Argon Snare Probes Two Functions, One Product– Efficiency in procedure Beamer Snare probes are dual mode combination probes allowing you to remove polyps and other abnormal tissue with subsequent argon coagulation of the site. This advantage eliminates the need to exchange instruments for performing the coagulation in a second step.

When it comes to challenging lesions, the powerful Beamer Argon Snare Probe allows you to do en bloc or piecemeal EMR followed by full argon ablation of the residual tissue to decrease the chance of polyp recurrence.

ConMed’s proprietary spiral and stiff monofilament loops are designed for grabbing flat lesions.

The Beamer Argon Snare program on the Beamer System CE600 allows easy toggling between resection and ablation therapies, making for a more efficient procedure, reducing the need to exchange devices and programs on the generator.

n Snare and resect n Ablate suspicious areas

Beamer Argon Probe – Superior outcomes

Ceramic tip n Visual contrast of the probe against mucosa

Long beam n Beam initiated without contact with the mucosa

Versatile therapy n 1.8mm, 2.3mm & 3.2mm provide choice in therapy

Braided Snare Monofilament Snare

Ceramic Tip Long Beam

Beam ItResect It

Page 7: SYSTEM CE600 - 208.218.54.142208.218.54.142/EndoTech_PDF/MCM201100_BeamerSystem_CE600.pdf · The Beamer Argon Snare program on the Beamer System CE600 allows easy toggling between

Control at your fingertipThe rotary control allows you to operate the system quickly, single-handedly and with complete comfort. All menu settings and machine parameters can be set and changed rapidly with a quick turn of the controller. The current operating state is immediately recognizable by the backlight, a status-indicating system specially developed on the Beamer® System.

Customize your programsThe system memory offers 99 storage positions for user-defined programs in addition to the preset standard program. These settings can be stored under specific indications, locations or your name – the choice is yours. The Last Used Programs can be instantly accessed from the system’s quick pick list.

Choose your settingAutomatic Mode Pictograms permit users to rapidly select outputs by the desired clinical application or effect. Beamer offers 5 preset automatic pictograms, each program designed to deliver optimal clinical results. All modes can be customized to meet the needs of the expert user as required.

Control Switch backlight code: n Yellow = Cutting

n Blue = Coagulation

n White = Menu

n Off = Inactive

Intuitive Design, with Quick Step Control

Polyp Cut I – Pulsed cut with minimal coagulationUse this setting for snare resection of flat based, sessile polyps, mucosectomy or piece meal resection.

 

Polyp Cut II – Pulsed cut with strong coagulation This setting addresses small or pedunculated polyps

 

Papilla Cut I – Pulse cut with no extra coagulationAppropriate for low hemorrhage incisions with a papillotome or pancreatic papillotomy

Papilla Cut II – Pulse cut with minimal coagulationThis setting is designed for low hemorrhage incisions with a papillotome, wire loop

ESD– Pulse cut for submucosa dissection with a needle knife

Quick Pick List of Last Used Programs.

Page 8: SYSTEM CE600 - 208.218.54.142208.218.54.142/EndoTech_PDF/MCM201100_BeamerSystem_CE600.pdf · The Beamer Argon Snare program on the Beamer System CE600 allows easy toggling between

© 2011, ConMed Corporation, 09/2011, Control #MCM201100

Beamer System CE600 Technical Data

Beamer ESU CE200Mains connectionPower requirements 100–240 V +_ 10%Mains current max. 6.3 AMains fuse 6.3 ANominal frequencies (mains) 50 / 60 HzPower input in standby mode 40 VAMax. power input 600 VA

Output dataCutting power (Pulse) max. 350 wattsCoagulation power max. 120 wattsHF frequencies 350 – 850 kHz

Weight and dimensionsWeight 8.3kgWidth x height x depth 390 x 182 x 435mm

StandardsClassification acc. to MDD IIbType of applied part CF; defibrillation-proofApproval/mark of conformity CE 0297, in compliance

with 93/42/EECLF leakage currents complying to IEC 601, Part 1 (testing in

connection with Beamer System)Duty type INT 10 s/30 s (= duty factor of 25%)

Beamer Plus CB200Power supply via Beamer Mate unitPower input max. 40 wattsArgon gas flow 0.1 to 8.0 I/min +_ 20%Weight 3.5kg

DimensionsWidth x height x depth 390 x 108 x 425mm

Beamer Cart CC200Height x length x width 862 x 582 x 658mmWeight 12kg

Beamer Irrigating Pump System CETEGP-100Electrical: Voltage/Current requirement 120V/240V~50-60Hz 30VAPump: Biopsy channel flow rate 0 - 200ml/minAux. water channel flow rate 0 - 500ml/min

Physical Dimensions: Height x Width x Depth 152 x 178 x 203mm Weight 2.27kg

Beamer System CE600 AccessoriesCatalog Number Description CE200-A01 Beamer Double Foot Pedal with Foot Lift bar CE200-A02 Beamer Single Foot Pedal with Foot Lift bar CE200-A05 Beamer Double Foot Pedal with Swap-Mode Button

and Foot Lift BarCE200-A04 Connecting Cable for Reusable Return Electrodes CB200-A01 Beamer Connecting Cable for Argon Probes SN-UAC Universal Monopolar Active Cord

Beamer Pump – On Demand IrrigationBeamer Irrigation Pump is used for on-demand endoscopic irrigation for improved visibility and permits the washing away of any blood/ particles or debris. The Beamer Pump allows the physician to control irrigation through a foot pedal.

ModularityThe Beamer® System is modular in design. You can upgrade your Beamer ESU with a Beamer Plus ABC® or Beamer Irrigation Pump at any time. The Beamer software can be upgraded as required, through the serial port connection, via a standard MS compatible computer. This feature helps keep your Beamer System updated without the need to return the device.

Double Foot-Pedal Unit with Integrated Swap-Mode ButtonThe Swap-Mode button located between the pedals allows users to switch between two linked programs by foot without the need to touch the generator.