sx004a-en-eu-example- pinned column using non slender h-section or rhs
TRANSCRIPT
-
8/10/2019 SX004a-En-EU-Example- Pinned Column Using Non Slender H-section or RHS
1/5
Document Ref: SX004a-EN-EU Sheet 1 of 4
CALCULATION SHEET
Title Example: Pinned column using non slender H-section or
RHS
Eurocode Ref EN 1993-1-1
Made by Matthias Oppe Date June 2005
Checked by Christian Mller Date June 2005
Example: Pinned column using non slender H-section or RHS
Within this worked example on a pinned column H-section or RHS in a
simple structure the column buckling resistance for various rolled cross-
sections (H-sections or RHS), different steel grades and member lengths
should be calculated.
Ed
8,
0
N
Ed
[m]
8,
0
N
0,1cr. =L
L 7,0cr. =
L
L
SN008
Partial factors
M0= 1,0
M1= 1,0
EN 1993-1-16.1(1)
Example: Pinned column using non slender H-section or RHS
CreatedonWednesday,
August18,
2010
Thismaterialiscopyright-allrightsreserved.
Useofthisdocumentissu
bjecttothetermsandconditionsoftheAccessSteelLicenceAgreement
http://www.access-steel.com/discovery/linklookup.aspx?id=SN008http://www.access-steel.com/discovery/linklookup.aspx?id=EC005http://www.access-steel.com/discovery/linklookup.aspx?id=EC005http://www.access-steel.com/discovery/linklookup.aspx?id=SN008 -
8/10/2019 SX004a-En-EU-Example- Pinned Column Using Non Slender H-section or RHS
2/5
Document Ref: SX004a-EN-EU Sheet 2 of 4
CALCULATION SHEET
Title Example: Pinned column using non slender H-section or
RHS
Eurocode Ref EN 1993-1-1
Made by Matthias Oppe Date June 2005
Checked by Christian Mller Date June 2005
Basic dataDesign a column of a multi-storey building in consideration of the followingdata.
Axial load : NEd= 2000 kN
Column length : 8,00 m
Buckling length : y-y axis: 00,800,80,1 = m
z-z axis: 60,500,87,0 = m
Steel grade : S235
Section classification: Class 1
HE 300 B Steel grade S235
Depth h= 300 mm
Width b= 300 mm
Web thickness tw= 11 mm
Flange thickness tf= 19 mm
Fillet r= 27 mm
z
z
y y
tf
tw
b
h
Euronorm
53-62
Section area A= 149 cm2
Second moment of area /yy Iy= 25170 cm4
Second moment of area /zz Iz= 8560 cm4
Yield strength
Steel grade S235
The maximum thickness is 19,0 mm < 40 mm, so :fy= 235 N/mm2
Note: The National Annex may impose either the values offyfrom theTable 3.1 or the values from the product standard.
EN 1993-1-1Table 3.1
Example: Pinned column using non slender H-section or RHS
CreatedonWednesday,
August18,
2010
Thismaterialiscopyright-allrightsreserved.
Useofthisdocumentissu
bjecttothetermsandconditionsoftheAccessSteelLicenceAgreement
http://www.access-steel.com/discovery/linklookup.aspx?id=EC016http://www.access-steel.com/discovery/linklookup.aspx?id=EC016 -
8/10/2019 SX004a-En-EU-Example- Pinned Column Using Non Slender H-section or RHS
3/5
Document Ref: SX004a-EN-EU Sheet 3 of 4
CALCULATION SHEET
Title Example: Pinned column using non slender H-section or
RHS
Eurocode Ref EN 1993-1-1
Made by Matthias Oppe Date June 2005
Checked by Christian Mller Date June 2005
Design buckling resistance of a compression memberTo determine the design column buckling resistanceNb,Rd, the reduction factor
for the relevant buckling curve must be defined. This factor is determined
by calculation of the non-dimensional slenderness based on the elasticcritical force for the relevant buckling mode and the cross sectional resistanceto normal forces.
Elastic critical forceNcr
The critical buckling force is calculated as follows :
28151800
25170210002
2
2
ycr,
y2
ycr, ,
L
EIN === kN
45657560
8560210002
2
2zcr,
z2
zcr, ,L
EIN =
=
= kN
Eis the Youngs modulus : E = 210000 N/mm2
Lcris the buckling length in the buckling plane considered: Lcr,y= 8,00 m
Lcr,z= 5,60 m
Non-dimensional slenderness
The non-dimensional slenderness is given by :
655028151
523149
ycr,
yy ,
,
,
N
A f =
==
787045657
523149
zcr,
yz ,
,
,
N
A f =
==
For slenderness 2,0 or for 04,0cr
Ed N
Nthe buckling effects may be
ignored and only cross sectional checks apply.
EN 1993-1-1 6.3.1.2(1)
EN 1993-1-1 6.3.1.2(4)
Example: Pinned column using non slender H-section or RHS
CreatedonWednesday,
August18,
2010
Thismaterialiscopyright-allrightsreserved.
Useofthisdocumentissu
bjecttothetermsandconditionsoftheAccessSteelLicenceAgreement
http://www.access-steel.com/discovery/linklookup.aspx?id=EC011http://www.access-steel.com/discovery/linklookup.aspx?id=EC011http://www.access-steel.com/discovery/linklookup.aspx?id=EC011http://www.access-steel.com/discovery/linklookup.aspx?id=EC011 -
8/10/2019 SX004a-En-EU-Example- Pinned Column Using Non Slender H-section or RHS
4/5
Document Ref: SX004a-EN-EU Sheet 4 of 4
CALCULATION SHEET
Title Example: Pinned column using non slender H-section or
RHS
Eurocode Ref EN 1993-1-1
Made by Matthias Oppe Date June 2005
Checked by Christian Mller Date June 2005
Reduction factorFor axial compression in members the value of depending on the non-
dimensional slenderness should be determined from the relevant bucklingcurve according to:
1,0but
-
1
22
+
=
where : ( )
++=
20,2-10,5
is an imperfection factor.
EN 1993-1-1 6.3.1.2(1)
For h/b= 300/300 = 1,00 < 1,2 and tf = 19,0 < 100 mm
- buckling about axis y-y:
Buckling curve b, imperfection factor = 0,34
( )[ ] 0,7920,6550,2-0,6550,3410,5 2y =++=
0,808
0,655-0,7920,792
1
22y =
+
=
- buckling about axis z-z:
Buckling curve c, imperfection factor = 0,49
( )[ ] 0,9530,7870,2-0,7870,4910,5 2z =++=
0,6710,787-0,9530,953
1
22z =
+=
= min (y;z) = min (0,808; 0,671)
= 0,671 < 1,0
(when > 1 then = 1)
Design buckling resistance of a compression member
5,23490,1
5,23149671,0
M1
y
Rdb, =
=
=
fA
N kN
Then we check:
0,185,05,2349
2000
Rdb,
Ed
-
8/10/2019 SX004a-En-EU-Example- Pinned Column Using Non Slender H-section or RHS
5/5
Example: Pinned column using non slender H-section or RHS
SX004a-EN-EU.doc
Quality Record
RESOURCE TITLE Example: Pinned column using non slender H-section or RHS
Reference(s)
ORIGINAL DOCUMENT
Name Company Date
Created by Matthias Oppe RWTH 16/06/05
Technical content checked by Christian Mller RWTH 16/06/05
Editorial content checked by D C Iles SCI 15/07/05
Technical content endorsed by the
following STEEL Partners:
1. UK G W Owens SCI 30/06/05
2. France A Bureau CTICM 30/06/05
3. Sweden A Olsson SBI 30/06/05
4. Germany C Mller RWTH 30/06/05
5. Spain J Chica Labein 30/06/05
Resource approved by TechnicalCoordinator
G W Owens SCI 07/06/06
TRANSLATED DOCUMENT
This Translation made and checked by:
Translated resource approved by:
Example: Pinned column using non slender H-section or RHS
CreatedonWednesday,
August18,
2010
Thismaterialiscopyright-allrightsreserved.
Useofthisdocumentissu