switched lan - mario baldi, pietro nicoletti copyright © 2002 - the mcgraw-hill companies srl...

17
“Switched LAN” - Mario Baldi, Pietro Copyright © 2002 - The McGraw-Hill Capitolo 11 Gestione di rete e ricerca guasti

Upload: saturnino-parente

Post on 01-May-2015

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

Capitolo 11

Gestione di rete e ricerca guasti

Page 2: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

AgentAgent

Managed Device(per esempio router)

MIB

Network Management Station

Managing Managing EntityEntity

Network

Query

Response3

1

Network management protocol

2

Page 3: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

Page 4: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

variabile1 ottetto variabile

Nome ValoreTipooper.

variabile variabile

Nome Valore

variabile variabile

Nome Valore

Page 5: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

t1

t2

A B

Collisione

Collision Window 512 bit-time

PREAM. SFD DSAP SSAP LEN. LLC PDU PAD FCS

Page 6: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

PACCHETTOSQE Test500 ns Minimo1500 ns Nominale

deve finire entro 3000 ns

600 ns

min.

Page 7: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

DS

AP

SS

AP

LE

N.

LL

C P

DU

PA

DF

CS

PR

EA

M.S

FDD

SA

PS

SA

PLE

N.

LLC

PD

U

PA

DFC

S

PREAM.S

FDDSAP

SSAPtY

PE

DATA

PADFC

S

PREAM.S

FDDSAP

SSAPLE

N.

LLC P

DU

PADFC

S

Page 8: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

PREAM. SFD DSAP SSAP LEN. LLC PDU PAD FCS

BPDU: Root Identifier = 7D00.00E01E3E28ACBPDU: Priority = 7D00BPDU: MAC Address = 00E01E3E28ACBPDU: BPDU: Root Path Cost = 500BPDU: ...

Page 9: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

guasto

PREAM. SFD DSAP SSAP LEN. LLC PDU PAD FCS

Page 10: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

LAN Analyzer

PREAM.SFDDSAPSSAP LEN. LLC PDU PAD FCS

PREAM.SFDDSAPSSAP LEN. LLC PDU PAD FCS

PREAM.SFDDSAPSSAP LEN. LLC PDU PAD FCS

PREAM.SFDDSAPSSAP LEN. LLC PDU PAD FCS

08-00-5A-00-00-0108-00-2B-00-00-0108-00-20-00-00-01

Primo indirizzo del primo lotto di indirizi MAC di:

IBMDigital EquipmentSUN Microsystem

1

10

20

30

40

50

60 7

080

9010

0

Page 11: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

LAN Analyzer

LAN Analyzer

R

Mirror port

Page 12: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

Raccolta di

informazioni

Causa e soluzione

Test e verifiche

Analisi

Page 13: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

2002

Da quando?

Dove?

Con quale frequenza?

In quali condizioni?

Particolarità collegate all’evento?Come si

manifesta?

1

10

20

30

40

50

60 7

080

9010

0

Page 14: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

Incisione della guainaTaglio del cavo

Pinzatura del connettore RJ45

Connettore RJ45

Piattina a 8 conduttori

Cavo a 4 coppie ritorte

Page 15: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

Contatto a lamaper conduttore a

trefoli

Contatto a forcellaper conduttore

solido

Page 16: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

Blu

1 2 3 4 5 6 7 8

Bianco-Verde

Verde

Arancio

Bianco-Arancio

Bianco-Blu

Bianco-Marrone

Marrone

Chiavetta in basso

Page 17: Switched LAN - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl Capitolo 11 Gestione di rete e ricerca guasti

“Switched LAN” - Mario Baldi, Pietro Nicoletti Copyright © 2002 - The McGraw-Hill Companies srl

Arancio

1 2 3 4 5 6 7 8

Bianco-Verde

Verde

BLUBianco-Arancio

Bianco-Blu

Bianco-Marrone

Marrone

Chiavetta in basso