suspension system - usg boral...– suspension system with high-performance healthcare coating water...

28
1 JUNE 2015 www.usgboral.com CEILING TILE SUSPENSION SYSTEM NEW ZEALAND

Upload: others

Post on 01-Apr-2020

15 views

Category:

Documents


0 download

TRANSCRIPT

1 JUNE 2015www.usgboral.com

CEILING TILE SUSPENSION SYSTEMNEW ZEALAND

2 1 JUNE 2015 | CEILING TILE GUIDE NZ

3CEILING TILE GUIDE NZ | 1 JUNE 2015

CONTENTS

Mars™ ClimaPlus™ 4

Mars™ ClimaPlus™ Healthcare 6

Mars™ ClimaPlus™ High-NRC 8

Clean Room Mars™ ClimaPlus™ 10

Impressions™ ClimaPlus™ 12

Radar™ ClimaPlus™ 14

Radar™ ClimaPlus™ High-NRC, High-CAC 16

Olympia II™ MICRO™ ClimaPlus™ 18

Olympia Micro™ ClimaPlus™ 20

Rock Face® ClimaPlus™ 22

Clean Room™ ClimaPlus™ 24

Nova White 26

Medium

-textured panel

Impressions™ ClimaPlus™

Advantages– Micro fissure non-directional pattern for a

cleaner, whiter appearance.– ClimaPlus 30-year lifetime system warranty to

withstand conditions up to 40˚C/95% relative humidity without visible sag when used with a Donn® Brand suspension system.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Schools– Corridors– Lobby areas– Offices– Retail stores– Cinemas / Theatres– Restaurants / Cafes

Substrate– Water-felted mineral fibre

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

ImpressIons Panels with ClimaPlus Performance/

Donn Centricitee DXT Suspension System

ESD InformationRecycled Content: 44%

4 1 JUNE 2015 | CEILING TILE GUIDE NZ

MARS™ CLIMAPLUS™

Fine-textured panel

Mars™ ClimaPlus™

Advantages– Fine, monolithic texture.– High light reflectance (LR .89).– Excellent noise reduction (NRC .70).– Durable, scratch-resistant, cleanable surface.– Low maintenance panels look like new for

years to come.– ClimaPlus 30-year lifetime system warranty to

withstand conditions up to 40˚C/95% relative humidity without visible sag when used with a Donn® Brand suspension system.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Open-plan offices– Corridors– Department stores– Offices with indirect lighting– Reception areas and lobbies– Restaurants

Substrate– X-Technology mineral fibre

Mars Panels with ClimaPlus Superior Performance/

Donn DX® Suspension System

ESD InformationRecycled Content: 76%ClimaPlus Superior Performance for Mould/Mildew

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

High Recycled Content

HRC

5CEILING TILE GUIDE NZ | 1 JUNE 2015

<

Mars™ ClimaPlus™ Information ESD Informationusgboral.com [email protected] [email protected]

Grid ProfileOptions

A B C DDX© DX Centricitee DXT Centricitee DXT

<

30 Year System Warranty– No visible sag– Mould/mildew protection

Physical Data/Footnotes

Weight4.7 kg/m2

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.39 ˚C/W

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha soft brush or vacuum

InstallationShall not begin until the building is fully enclosed, watertight, dry, permanent heating and cooling equipment is in operation, residual moisture from wet trades (eg. terrazzo, concrete, plaster) has dissipated, and is free of chemical fumes. Do not mix production lots in the same ceiling area.

ScrubbabilityExceeds 1000+ scrub cycles without surface break or the extent of abrasion (ASTM D2486).

WashabilityExceeds 1000+ wash cycles without surface break or the extent of abrasion (ATSM D4828).

Water resistanceAbsorption of 1,660 gm/m2 per Cobbtest (T441 om-84).

Proprietary technologyThis product’s unique combination of sag resistance and sound performance results from proprietary technology.

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

Cleaning RecommendationsTo clean panel, use a clean, white cloth with water or a mild detergent and wipe surface. To disinfect panel, lightly spray surface and wipe clean with a clean, white cloth. Acceptable colourless disinfectants include:– Hydrogen peroxide– Isopropyl alcohol– Quaternary ammonium– Sodium hypochlorite

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14144. LR values are shown as averages5. Panel face and back surfaces

treated with a patented, broad-spectrum antimicrobial standard formulation that inhibits and retards the growth of mould/mildew.

M/5-14

Legend O/ SAC 0.85 + all options (500-4000 Hz speech range)

Low Emissions (VOC Class) ClimaPlus Performance High Recycled Content

Classified as low-emitting per standards established by the Lifetime system Warranty (maximum of 30 years) Classified as containing greater than 50% totalCollaborative for High-Performance Schools (CHPS), following to withstand conditions up to 40˚C/95%RH when recycled content. Total recycled content is based onCalifornia Specification 01350 testing methods. Low-emitting used with USG DONN suspension systems. panel composition of post-consumer and pre-consumeris defined as having less than 13.5 ppb. (0.017mg/m3) (post industrial) recycled content per FTC guidelines.

HRC

HRC

Low emitting performance meets CA Specification 01350 (CA Dept. of HealthServices Standard Practice for the testing of VOC emissions) and is listed onCHPS database for low-emitting materials. USG Certificate of Compliance for LowVOC Emissions) is available on request. Low emitting is defined as having less than0.009 mg/m3.

Reaction to Fire

Standard Flame Spread Smoke Developed ASTM E84 < 25 < 50 AS/NZS 3837 Group Number Classification : 1 unsprinklered ISO 5660 Parts 1 & 2 Group Number Classification : 1 - S

New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid VOC Recycled Options Emissions Content

SQ 600 x 600 x 19mm Class A ME86185 .70 35-39 .89 White A, C Low 76%

1200 x 600 x 19mm Class A ME88185 .70 35-39 .89 White A, C Low 76%

SLT 600 x 600 x 19mm Class A ME86785 .70 35-39 .89 White B Low 76%

1200 x 600 x 19mm Class A ME88785 .70 35-39 .89 White B Low 76%

FLB 600 x 600 x 19mm Class A ME86985 .70 35-39 .89 White D Low 76%

1200 x 600 x 19mm Class A ME88985 .70 35-39 .89 White D Low 76%

Mars ClimaPlus

Panels

O/

MARS™ CLIMAPLUS™

6 1 JUNE 2015 | CEILING TILE GUIDE NZ

Fine-textured panel

Mars™ ClimaPlus™

Healthcare

Advantages– Water repellent membrane designed to be

durable and safe with common disinfectants6.– Washable, scrubbable and soil resistant finish

Impact and scratch resistant.– Exceeds JIS Z 2801 standard for antimicrobial

performance, 3rd party certified.– Meets the requirement for PC1 and

PC2 physical containment facilities6.– High light reflectance (LR .89).– Excellent noise reduction (NRC .70).– ClimaPlus 30-year lifetime system warranty

against visible sag, mould and mildew.

Grid Options

Donn DX 24mm Donn Certricitee 15mm - available with high performance antimicrobial coating - available with high performance antimicrobial coating

Applications– Patient rooms– Treatment rooms– Nurses’ stations– Waiting rooms– Laboratories– Corridors– Toilets and restrooms– Kitchen/food-prep areas

Substrate– X-Technology mineral fibre

mars Healthcare with ClimaPlus with high performance Healthcare Coating/

Donn DX® Suspension System with high-performance Healthcare Coating

ESD InformationRecycled Content: 75%ClimaPlus Superior Performance for Mould/Mildew

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat-14

Increase Reduce Internal Low Volatile Lighting Ceilings, Daylight Lighting Noise Level Organic Low Mould Density Calculator Levels Levels Reduction Compounds Formaldehyde Prevention Reduction

H H H 3 3 3 H 3

High Recycled Content

HRCNew—Water Repellent Membrane!MARS™ CLIMAPLUS™ HEALTHCARE NEW – WATER REPELLENT MEMBRANE

7CEILING TILE GUIDE NZ | 1 JUNE 2015

Mars™ ClimaPlus™

Healthcare

Information ESD Informationusgboral.com [email protected] [email protected]

Grid ProfileOptions

A B C DDX© DX Centricitee DXT Centricitee DXT

30 Year System Warranty– No visible sag– Mould/mildew/bacteria protection

Physical Data/Footnotes

Weight5.2 kg/m2

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.39 ˚C/W

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha soft brush or vacuum

InstallationShall not begin until the building is fully enclosed, watertight, dry, permanent heating and cooling equipment is in operation, residual moisture from wet trades (eg. terrazzo, concrete, plaster) has dissipated, and is free of chemical fumes. Do not mix production lots in the same ceiling area.

ASTM D2486 scrubbability test(standard test)

ASTM D4828 washability test (modified test)

Water RepellencyCobb method (Tappi T441 om-84)Water Drop Test

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14144. LR values are shown as averages5. Panel face and back surfaces

treated with a proprietary, broad-spectrum antimicrobial standard formulation that inhibits and retards the growth of mould/mildew.

6. Cleaning RecommendationsTo clean panel, use a clean, white cloth with water or a mild detergent and wipe surface. To disinfect panel, lightly spray surface and wipe clean with a clean, white cloth. Acceptable colourless disinfectants include:– Hydrogen peroxide– Isopropyl alcohol– Quaternary ammonium– Sodium hypochlorite Do not mix cleaners. Follow cleaner manufacturer’s recommendations.

7. 99.0% in less than 72 hours (tested to JIS Z 2801):

Legend O/ SAC 0.85 + all options (500-4000 Hz speech range)

Low Emissions (VOC Class) ClimaPlus Superior Performance5 High Recycled Content

Classified as low-emitting per standards established by the Contains a broad-spectrum antimicrobial additive Classified as containing greater than 50% totalCollaborative for High-Performance Schools (CHPS), following on the face and back of the panel that provides recycled content. Total recycled content is based onCalifornia Specification 01350 testing methods. Low-emitting resistance against the growth of mould and mildew. panel composition of post-consumer and pre-consumeris defined as having less than 13.5 ppb. (0.017mg/m3) (post industrial) recycled content per FTC guidelines.

HRC

HRC

Low emitting performance meets CA Specification 01350 (CA Dept. of HealthServices Standard Practice for the testing of VOC emissions) and is listed onCHPS database for low-emitting materials. USG Certificate of Compliance for LowVOC Emissions) is available on request. Low emitting is defined as having less than0.009 mg/m3.

New-Water Repellent Membrane!

Reaction to Fire

Standard Flame Spread Smoke Developed ASTM E84 < 25 < 50 AS/NZS 3837 Group Number Classification : 1 unsprinklered ISO 5660 Parts 1 & 2 Group Number Classification : 1 - S

MH/5-14

An antimicrobial formula designed to adhere to your ceiling designThe kill rate for the following micro-organisms that land on the surface of the tile is 99% in less than 24 hours. (tested to JIS Z2801): E-coli, Staphylococcus Aureus, Klebsiella Pneumoniae, S. aureus MRSA, Acinebacter Baumanii, Canadida Albicans, Streptococcus Pnuemoniae, Bacillus Cereus7, Aspergillus Niger7. Testing completed by 3rd party in laboratory conditions.

New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid VOC Recycled Options Emissions Content

SQ 600 x 600 x 19mm Class A ME86169 .70 35-39 .89 White A, C Low 76%

1200 x 600 x 19mm Class A ME88189 .70 35-39 .89 White A, C Low 76%

SLT 600 x 600 x 19mm Class A ME86684 .70 35-39 .89 White B Low 76%

1200 x 600 x 19mm Class A ME88683 .70 35-39 .89 White B Low 76%

FLB 600 x 600 x 19mm Class A ME86984 .70 35-39 .89 White D Low 76%

1200 x 600 x 19mm Class A ME88983 .70 35-39 .89 White D Low 76%

Mars ClimaPlus

Healthcare Panels

O/

Anti-Mould5

& Mildew

MARS™ CLIMAPLUS™ HEALTHCARE NEW – WATER REPELLENT MEMBRANE

8 1 JUNE 2015 | CEILING TILE GUIDE NZ

Fine-textured panel

Mars™ ClimaPlus™

High-NRC

Advantages– Excellent noise reduction (NRC .80).– Fine, monolithic texture.– High light reflectance (LR .89).– Durable, scratch-resistant, cleanable surface.– Low maintenance panels look like new for

years to come.– ClimaPlus 30-year lifetime system warranty

against visible sag, mould and mildew.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Open-plan offices– Corridors– Department stores– Offices with indirect lighting– Reception areas and lobbies– Restaurants– Classrooms

Substrate– X-Technology mineral fibre

mars High-NRC with ClimaPlus Superior Performance/

Donn DX® Suspension System

ESD InformationRecycled Content: 76%ClimaPlus Superior Performance for Mould/Mildew

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

High Recycled Content

HRCMARS™ CLIMAPLUS™ High-NRC

Fine-textured panel

Mars™ ClimaPlus™

High-NRC

Advantages– Excellent noise reduction (NRC .80).– Fine, monolithic texture.– High light reflectance (LR .89).– Durable, scratch-resistant, cleanable surface.– Low maintenance panels look like new for

years to come.– ClimaPlus 30-year lifetime system warranty

against visible sag, mould and mildew.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Open-plan offices– Corridors– Department stores– Offices with indirect lighting– Reception areas and lobbies– Restaurants– Classrooms

Substrate– X-Technology mineral fibre

mars High-NRC with ClimaPlus Superior Performance/

Donn DX® Suspension System

ESD InformationRecycled Content: 76%ClimaPlus Superior Performance for Mould/Mildew

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

High Recycled Content

HRC

9CEILING TILE GUIDE NZ | 1 JUNE 2015

<

Mars™ ClimaPlus™

High-NRC

Information ESD Informationusgboral.com [email protected] [email protected]

Grid ProfileOptions

A B C DDX© DX Centricitee DXT Centricitee DXT

<

30 Year System Warranty– No visible sag– Mould/mildew protection

Physical Data/Footnotes

Weight5.9 kg/m2

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.39 ˚C/W

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha soft brush or vacuum

InstallationShall not begin until the building is fully enclosed, watertight, dry, permanent heating and cooling equipment is in operation, residual moisture from wet trades (eg. terrazzo, concrete, plaster) has dissipated, and is free of chemical fumes. Do not mix production lots in the same ceiling area.

ScrubbabilityExceeds 1000+ scrub cycles without surface break or the extent of abrasion (ASTM D2486).

ASTM D2486 scrubbability test(standard test)

ASTM D4828 washability test (modified test)

Water RepellencyCobb method (Tappi T441 om-84)Water Drop Test

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

Cleaning RecommendationsTo clean panel, use a clean, white cloth with water or a mild detergent and wipe surface.

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14144. LR values are shown as averages5. Panel face and back surfaces

treated with a proprietary, broad-spectrum antimicrobial standard formulation that inhibits and retards the growth of mould/mildew.

Legend O/ SAC 0.85 + all options (500-4000 Hz speech range)

Low Emissions (VOC Class) ClimaPlus Superior Performance5 High Recycled Content

Classified as low-emitting per standards established by the Contains a broad-spectrum antimicrobial additive Classified as containing greater than 50% totalCollaborative for High-Performance Schools (CHPS), following on the face and back of the panel that provides recycled content. Total recycled content is based onCalifornia Specification 01350 testing methods. Low-emitting resistance against the growth of mould and mildew. panel composition of post-consumer and pre-consumeris defined as having less than 13.5 ppb. (0.017mg/m3) (post industrial) recycled content per FTC guidelines.

HRC

HRC

Low emitting performance meets CA Specification 01350 (CA Dept. of HealthServices Standard Practice for the testing of VOC emissions) and is listed onCHPS database for low-emitting materials. USG Certificate of Compliance for LowVOC Emissions) is available on request. Low emitting is defined as having less than0.009 mg/m3.

Reaction to Fire

Standard Flame Spread Smoke Developed ASTM E84 < 25 < 50 AS/NZS 3837 Group Number Classification : 1 unsprinklered ISO 5660 Parts 1 & 2 Group Number Classification : 1 - S

MN/5-14New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid VOC Recycled Options Emissions Content

SQ 600 x 600 x 22mm Class A ME86100 .80 35-39 .89 White A, C Low 76%

1200 x 600 x 22mm Class A ME86300 .80 35-39 .89 White A, C Low 76%

SLT 600 x 600 x 22mm Class A ME87200 .80 35-39 .89 White B Low 76%

1200 x 600 x 22mm Class A ME89600 .80 35-39 .89 White B Low 76%

FLB 600 x 600 x 22mm Class A ME87100 .80 35-39 .89 White D Low 76%

1200 x 600 x 22mm Class A ME89500 .80 35-39 .89 White D Low 76%

Mars ClimaPlus

High-NRC Panels

O/

Anti-Mould5

& Mildew

MARS™ CLIMAPLUS™ High-NRC

10 1 JUNE 2015 | CEILING TILE GUIDE NZ

Fine-textured panel

Clean Room™ Mars ClimaPlus™

Advantages– Clean Rooms ISO Class 5 (Class 100).– Water repellent membrane designed to be

durable and safe with common disinfectants6.– Washable, scrubbable and soil resistant finish

Impact and scratch resistant.– Exceeds JIS Z 2801 standard for antimicrobial

performance, 3rd party certified.– Meets the requirement for PC1 and

PC2 physical containment facilities6.– High light reflectance (LR .89).– Excellent noise reduction (NRC .70).– ClimaPlus 30-year lifetime system warranty

against visible sag, mould and mildew.Grid Options

Donn DX 24mm - available with high performance antimicrobial coating

Applications– Patient rooms– Treatment rooms– Emergency rooms– Nurses’ stations– Waiting rooms– Laboratories– Corridors– Toilets and restrooms– Kitchen/food-prep areas

Substrate– X-Technology mineral fibre

Clean Room Mars with ClimaPlus Superior Performance/

Donn DX® Suspension System with high-performance Healthcare Coating

ESD InformationRecycled Content: 75%ClimaPlus Superior Performance for Mould/Mildew

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat-14

Increase Reduce Internal Low Volatile Lighting Ceilings, Daylight Lighting Noise Level Organic Low Mould Density Calculator Levels Levels Reduction Compounds Formaldehyde Prevention Reduction

H H H 3 3 3 H 3

High Recycled Content

HRCCLEAN ROOM MARS™ CLIMAPLUS™

Fine-textured panel

Mars™ ClimaPlus™

High-NRC

Advantages– Excellent noise reduction (NRC .80).– Fine, monolithic texture.– High light reflectance (LR .89).– Durable, scratch-resistant, cleanable surface.– Low maintenance panels look like new for

years to come.– ClimaPlus 30-year lifetime system warranty

against visible sag, mould and mildew.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Open-plan offices– Corridors– Department stores– Offices with indirect lighting– Reception areas and lobbies– Restaurants– Classrooms

Substrate– X-Technology mineral fibre

mars High-NRC with ClimaPlus Superior Performance/

Donn DX® Suspension System

ESD InformationRecycled Content: 76%ClimaPlus Superior Performance for Mould/Mildew

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

High Recycled Content

HRC

11CEILING TILE GUIDE NZ | 1 JUNE 2015

Clean Room Mars™ ClimaPlus™

Grid ProfileOptions

A DX©

30 Year System Warranty– No visible sag– Mould/mildew/bacteria protection

Physical Data/Footnotes

Weight5.2 kg/m2

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.39 ˚C/W

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha soft brush or vacuum

InstallationShall not begin until the building is fully enclosed, watertight, dry, permanent heating and cooling equipment is in operation, residual moisture from wet trades (eg. terrazzo, concrete, plaster) has dissipated, and is free of chemical fumes. Do not mix production lots in the same ceiling area.

ASTM D2486 scrubbability test(standard test)

ASTM D4828 washability test (modified test)

Water RepellencyCobb method (Tappi T441 om-84)Water Drop Test

ISO 14644-1 Clean RoomISO Class 5

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14144. LR values are shown as averages5. Panel face and back surfaces

treated with a proprietary, broad-spectrum antimicrobial standard formulation that inhibits and retards the growth of mould/mildew.

6. Cleaning RecommendationsTo clean panel, use a clean, white cloth with water or a mild detergent and wipe surface. To disinfect panel, lightly spray surface and wipe clean with a clean, white cloth. Acceptable colourless disinfectants include:– Hydrogen peroxide– Isopropyl alcohol– Quaternary ammonium– Sodium hypochlorite Do not mix cleaners. Follow cleaner manufacturer’s recommendations.

7. Cut edges must be resealed with a white latex based paint

Legend O/ SAC 0.85 + all options (500-4000 Hz speech range)

Low Emissions (VOC Class) ClimaPlus Superior Performance5 High Recycled Content

Classified as low-emitting per standards established by the Contains a broad-spectrum antimicrobial additive Classified as containing greater than 50% totalCollaborative for High-Performance Schools (CHPS), following on the face and back of the panel that provides recycled content. Total recycled content is based onCalifornia Specification 01350 testing methods. Low-emitting resistance against the growth of mould and mildew. panel composition of post-consumer and pre-consumeris defined as having less than 13.5 ppb. (0.017mg/m3) (post industrial) recycled content per FTC guidelines.

HRC

HRC

Low emitting performance meets CA Specification 01350 (CA Dept. of HealthServices Standard Practice for the testing of VOC emissions) and is listed onCHPS database for low-emitting materials. USG Certificate of Compliance for LowVOC Emissions) is available on request. Low emitting is defined as having less than0.009 mg/m3.

Reaction to Fire

Standard Flame Spread Smoke Developed ASTM E84 < 25 < 50 AS/NZS 3837 Group Number Classification : 1 unsprinklered ISO 5660 Parts 1 & 2 Group Number Classification : 1 - S

CRM/12-14New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Information ESD Informationusgboral.com [email protected] [email protected]

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid VOC Recycled Options Emissions Content

SQ 600 x 600 x 19mm Class A ME86169CR .70 35-39 .89 White A Low 75%

1200 x 600 x 19mm Class A ME88189CR .70 35-39 .89 White A Low 75%

Clean Room™ Mars™ ClimaPlus™

Panels

O/

Anti-Mould5

& Mildew

CLEAN ROOM MARS™ CLIMAPLUS™

12 1 JUNE 2015 | CEILING TILE GUIDE NZ

Medium

-textured panel

Impressions™ ClimaPlus™

Advantages– Micro fissure non-directional pattern for a

cleaner, whiter appearance.– ClimaPlus 30-year lifetime system warranty to

withstand conditions up to 40˚C/95% relative humidity without visible sag when used with a Donn® Brand suspension system.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Schools– Corridors– Lobby areas– Offices– Retail stores– Cinemas / Theatres– Restaurants / Cafes

Substrate– Water-felted mineral fibre

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

ImpressIons Panels with ClimaPlus Performance/

Donn Centricitee DXT Suspension System

ESD InformationRecycled Content: 44%

IMPRESSIONS™ CLIMAPLUS™

13CEILING TILE GUIDE NZ | 1 JUNE 2015

Physical Data/Footnotes

Weight3.0-4.0 kg/m2

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.25 m2 ˚C/W

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha soft brush or vacuum

InstallationShall not begin until the building is fullyenclosed, watertight, dry, permanent heatingand cooling equipment is in operation,residual moisture from wet trades (eg.terrazzo, concrete, plaster) has dissipated,and is free of chemical fumes. Do not mixproduction lots in the same ceiling area.

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14144. LR values are shown as averages

Impressions™ ClimaPlus™ Information ESD Informationusgboral.com [email protected] [email protected]

Grid ProfileOptions

A B CDX© DX Centricitee DXT

<

Legend

Low Emissions (VOC Class) ClimaPlus Performance

Classified as low-emitting per standards established by the Lifetime system Warranty (maximum of 30 years)Collaborative for High-Performance Schools (CHPS), following to withstand conditions up to 40˚C/95%RH whenCalifornia Specification 01350 testing methods. Low-emitting used with USG DONN suspension systems.is defined as having less than 13.5 ppb. (0.017 mg/m3)

<

30 Year System Warranty– No visible sag

ImpressIons ClimaPlus Panels

Reaction to Fire

Standard Flame Spread Smoke Developed ASTM E84 < 25 < 50 AS/NZS 3837 Group Number Classification : 1 unsprinklered ISO 5660 Parts 1 & 2 Group Number Classification : 1 - S

IM/5-14New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Ecospecifier Global Green Tag Certified Device

Stacked Inline

Please note that while the devices are dispalyed and supplied as whole units they can be split and used as individual elements as shown below.

Stacked Inline

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid VOC Recycled Options Emissions Content

SQ 600 x 600 x 16mm Class A ME903 .50-.60 33-35 .84 White A Low 45%

1200 x 600 x 16mm Class A ME904 .50-.60 33-35 .84 White A Low 45%

SLT 600 x 600 x 16mm Class A ME905 .50-.60 33-35 .84 White B Low 45%

1200 x 600 x 16mm Class A ME908 .50-.60 33-35 .84 White B Low 45%

FLB 600 x 600 x 16mm Class A ME916 .50-.60 33-35 .84 White C Low 45%

Low emitting performance meets CA Specification 01350 (CA Dept. of HealthServices Standard Practice for the testing of VOC emissions) and is listed onCHPS database for low-emitting materials. USG Certificate of Compliance for LowVOC Emissions) is available on request. Low emitting is defined as having less than0.009 mg/m3.

IMPRESSIONS™ CLIMAPLUS™

14 1 JUNE 2015 | CEILING TILE GUIDE NZ

Medium

-textured panel

Radar™ ClimaPlus™

Advantages– True non-directional pattern allows installation in

any direction.– ClimaPlus 30-year lifetime system warranty to

withstand conditions up to 40˚C/95% relative humidity without visible sag when used with a Donn® Brand suspension system.

– Optional FirecoDe™ formulation for Fire Rated ceilings

– High-durability panels are 55% more durable than standard panels.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Schools– Corridors– Lobby areas– Offices– Retail stores– Cinemas / Theatres– Restaurants / Cafes

Substrate– Water-felted mineral fibre

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

raDar Panels with ClimaPlus Performance/

Donn DX/DXL Suspension System

ESD InformationRecycled Content: 28-50%

RADAR™ CLIMAPLUS™

15CEILING TILE GUIDE NZ | 1 JUNE 2015

Grid ProfileOptions

Physical Data/Footnotes

<

Radar™ ClimaPlus™ Information ESD Informationusgboral.com [email protected] [email protected]

A B C DDX©/DXL™ DX/DXL Centricitee DXT Centricitee DXT

Weight3.0-4 kg/m2

5.6 kg/m2 Firecode4.2 kg/m2 (Two/24)

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.25 (Class A)R 0.28 (Firecode)R 0.3 (Two/24)

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha soft brush or vacuum

InstallationShall not begin until the building is fullyenclosed, watertight, dry, permanent heatingand cooling equipment is in operation,residual moisture from wet trades (eg.terrazzo, concrete, plaster) has dissipated,and is free of chemical fumes. Do not mixproduction lots in the same ceiling area.

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14144. LR values are shown as averages

Legend

Low Emissions (VOC Class) ClimaPlus Performance

Classified as low-emitting per standards established by the Lifetime system Warranty (maximum of 30 years)Collaborative for High-Performance Schools (CHPS), following to withstand conditions up to 40˚C/95%RH whenCalifornia Specification 01350 testing methods. Low-emitting used with USG DONN suspension systems.is defined as having less than 13.5 ppb. (0.017mg/m3)

<

30 Year System Warranty– No visible sag

Low emitting performance meets CA Specification 01350 (CA Dept. of HealthServices Standard Practice for the testing of VOC emissions) and is listed onCHPS database for low-emitting materials. USG Certificate of Compliance for LowVOC Emissions) is available on request. Low emitting is defined as having less than0.009 mg/m3.

R/5-14New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid VOC Abuse- Recycled Min. Options Emissions Resistant Content

SQ 600 x 600 x 16mm Class A ME2210 .50-.60 33 .84 White A Low 28 – 45%

1200 x 600 x 16mm Class A ME2410 .50-.60 34 .84 White A Low 28 – 45%

1200 x 600 x 16mm ME2415 .50-.60 35 .84 White A Low 41 – 49%

SLT 600 x 600 x 16mm Class A ME2220 .50-.60 33 .84 White B Low 28 - 45%

1200 x 600 x 16mm Class A ME2420 .50-.60 34 .84 White B Low 28 – 45%

1200 x 600 x 16mm ME2425 .50-.60 35 .84 White B Low 49 – 58%

FLB 600 x 600 x 16mm Class A ME2230 .50-.60 33 .84 White C Low 28 – 45%

SQ 600 x 600 x 15mm Class A ME2207 .50-.60 35 .84 White A Low 43%

1200 x 600 x 15mm Class A ME2407 .50-.60 35 .84 White A Low 43%

SLT 600 x 600 x 15mm Class A ME2227 .50-.60 35 .84 White B Low 43%

SLT 1200 x 600 x 19mm Class A ME2842 .50-.60 35 .84 White B Low 57.3%

ILT 1200 x 600 x 19mm Class A ME2844 .50-.60 35 .84 White D Low 57.3%

RadaR ClimaPlus

Panels

RadaR ClimaPlus

High-DurabilityPanels

RadaR ClimaPlus

Illusion Two/24Panels

Reaction to Fire

Standard Flame Spread Smoke Developed ASTM E84 < 25 < 50 AS/NZS 3837 Group Number Classification : 1 unsprinklered ISO 5660 Parts 1 & 2 Group Number Classification : 1 - S

Ecospecifier Global Green Tag Certified Device

Stacked Inline

Please note that while the devices are dispalyed and supplied as whole units they can be split and used as individual elements as shown below.

Stacked Inline

RADAR™ CLIMAPLUS™

16 1 JUNE 2015 | CEILING TILE GUIDE NZ

Medium

-textured panel

Radar™ ClimaPlus™ High-NRC, High-CAC

Advantages– Non-directional all-purpose ceiling pattern.– Available with 40 CAC for increased room-to-

room speech privacy or .70 NRC for greater sound control in open-plan areas.

– ClimaPlus 30-year lifetime system warranty to withstand conditions up to 40˚C/95% relative humidity without visible sag when used with a Donn® Brand suspension system.

– FirecoDe™ formulation designed for Fire Rated ceilings.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Conference rooms– Open office plans– Privacy rooms

Substrate– Water-felted mineral fibre

raDar High-NRC Panels with ClimaPlus Performance/

Donn DX/DXL Suspension System

ESD InformationRecycled Content: 58%

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

High Recycle Content

HRC

RADAR™ CLIMAPLUS™ High-NRC, High-CAC

Fine-textured panel

Mars™ ClimaPlus™

High-NRC

Advantages– Excellent noise reduction (NRC .80).– Fine, monolithic texture.– High light reflectance (LR .89).– Durable, scratch-resistant, cleanable surface.– Low maintenance panels look like new for

years to come.– ClimaPlus 30-year lifetime system warranty

against visible sag, mould and mildew.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Open-plan offices– Corridors– Department stores– Offices with indirect lighting– Reception areas and lobbies– Restaurants– Classrooms

Substrate– X-Technology mineral fibre

mars High-NRC with ClimaPlus Superior Performance/

Donn DX® Suspension System

ESD InformationRecycled Content: 76%ClimaPlus Superior Performance for Mould/Mildew

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

High Recycled Content

HRC

17CEILING TILE GUIDE NZ | 1 JUNE 2015

Physical Data/Footnotes

<

Radar™ ClimaPlus™ High-NRC, High-CAC

Information ESD Informationusgboral.com [email protected] [email protected]

Weight5.6-5.8 kg/m2

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.28 (15mm panels)R 0.33 (19mm panels)

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha soft brush or vacuum

InstallationShall not begin until the building is fullyenclosed, watertight, dry, permanent heatingand cooling equipment is in operation,residual moisture from wet trades (eg.terrazzo, concrete, plaster) has dissipated,and is free of chemical fumes. Do not mixproduction lots in the same ceiling area.

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14144. LR values are shown as averages

Legend

Low Emissions (VOC Class) ClimaPlus Performance High Recycled Content

Classified as low-emitting per standards established by the Lifetime system Warranty (maximum of 30 years) Classified as containing greater than 50% totalCollaborative for High-Performance Schools (CHPS), following to withstand conditions up to 40˚C/95%RH when recycled content. Total recycled content is based onCalifornia Specification 01350 testing methods. Low-emitting used with USG DONN suspension systems. panel composition of post-consumer and pre-consumeris defined as having less than 13.5 ppb. (0.017mg/m3) (post industrial) recycled content per FTC guidelines.

<

Grid ProfileOptions

A B C DX©/DXL™ DX/DXL Centricitee DXT

30 Year System Warranty– No visible sag

HRC

HRC

Low emitting performance meets CA Specification 01350 (CA Dept. of HealthServices Standard Practice for the testing of VOC emissions) and is listed onCHPS database for low-emitting materials. USG Certificate of Compliance for LowVOC Emissions) is available on request. Low emitting is defined as having less than0.009 mg/m3.

Reaction to Fire

Standard Flame Spread Smoke Developed ASTM E84 < 25 < 50 AS/NZS 3837 Group Number Classification : 1 unsprinklered ISO 5660 Parts 1 & 2 Group Number Classification : 1 - S

RH/5-14New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid VOC Recycled Min. Min. Options Emissions Content

SQ 1200 x 600 x 15mm ME22310 .55 40 .84 White A Low 58%

SQ 600 x 600 x 19mm ME22111 .70 35 .84 White A Low 58%

1200 x 600 x 19mm ME22311 .70 35 .84 White A Low 58%

SLT 600 x 600 x 19mm ME22121 .70 35 .84 White B Low 58%

1200 x 600 x 19mm ME22122 .70 35 .84 White B Low 58%

FLB 600 x 600 x 19mm ME22127 .70 35 .84 White C Low 58%

SQ 1200 x 600 x 22mm Class A ME22441 .70 40 .84 White A Low 44%

1200 x 600 x 19mm ME22541 .70 40 .84 White A Low 58%

SLT 600 x 600 x 19mm ME22523 .70 40 .84 White B Low 56%

FLB 600 x 600 x 19mm ME22527 .70 40 .84 White C Low 58%

RadaR ClimaPlus

High-CAC Panel

RadaR ClimaPlus

High-NRC Panels

RadaR ClimaPlus

High-NRC High-CAC Panels

RADAR™ CLIMAPLUS™ High-NRC, High-CAC

18 1 JUNE 2015 | CEILING TILE GUIDE NZ

Fine-textured panel

Olympia II Micro™ ClimaPlus™

Advantages– Nondirectional pattern reduces installation time

and waste.– Economical, fine-textured panel.– Excellent light reflectance enhances indirect

lighting of a space.– ClimaPlus 30-year lifetime system warranty to

withstand conditions up to 40˚C/95% relative humidity without visible sag when used with a Donn® Brand suspension system.

– .65 NRC

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Classrooms– Hotels– Reception and lobby areas– Restaurants– Retail stores– Offices

Substrate– Water-felted

olympia micro ii Panels with ClimaPlus Performance/

Donn Suspension System

ESD InformationRecycled Content: 56.3%

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

High Recycled Content

HRCOLYMPIA II™ MICRO™ CLIMAPLUS™

Fine-textured panel

Mars™ ClimaPlus™

High-NRC

Advantages– Excellent noise reduction (NRC .80).– Fine, monolithic texture.– High light reflectance (LR .89).– Durable, scratch-resistant, cleanable surface.– Low maintenance panels look like new for

years to come.– ClimaPlus 30-year lifetime system warranty

against visible sag, mould and mildew.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Open-plan offices– Corridors– Department stores– Offices with indirect lighting– Reception areas and lobbies– Restaurants– Classrooms

Substrate– X-Technology mineral fibre

mars High-NRC with ClimaPlus Superior Performance/

Donn DX® Suspension System

ESD InformationRecycled Content: 76%ClimaPlus Superior Performance for Mould/Mildew

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

High Recycled Content

HRC

19CEILING TILE GUIDE NZ | 1 JUNE 2015

Physical Data/Footnotes

<

Olympia II Micro™ ClimaPlus™ Information ESD Informationusgboral.com [email protected] [email protected]

Weight4.64 kg/m2

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.30m2 ˚C/W

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha soft brush or vacuum

InstallationShall not begin until the building is fullyenclosed, watertight, dry, permanent heating and cooling equipment is in operation, residual moisture from wet

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

trades (eg. terrazzo, concrete, plaster) has dissipated, and is free of chemical fumes. Do not mix production lots in the same ceiling area.

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14144. LR values are shown as averages

Grid ProfileOptions

A B C DX© DX Centricitee DXT

<

30 Year System Warranty– No visible sag

Reaction to Fire

Standard Flame Spread Smoke Developed ASTM E84 < 25 < 50 AS/NZS 3837 Group Number Classification : 1 unsprinklered ISO 5660 Parts 1 & 2 Group Number Classification : 1 - S

HRC

Legend

Low Emissions (VOC Class) ClimaPlus Performance High Recycled Content

Classified as low-emitting per standards established by the Lifetime system Warranty (maximum of 30 years) Classified as containing greater than 50% totalCollaborative for High-Performance Schools (CHPS), following to withstand conditions up to 40˚C/95%RH when recycled content. Total recycled content is based onCalifornia Specification 01350 testing methods. Low-emitting used with USG DONN suspension systems. panel composition of post-consumer and pre-consumeris defined as having less than 13.5 ppb. (0.017mg/m3) (post industrial) recycled content per FTC guidelines.

IM/4/12OMII/5-14New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid VOC Recycled Options Emissions Content

SQ 600 x 600 x 19mm Class A ME4750-D .65 35-39 .89 White A Low 56.3%

1200 x 600 x 19mm Class A ME4751-D .65 35-39 .89 White A Low 56.3%

SQ 1200 x 300 x 19mm Class A ME1230-D .65 35-39 .89 White A Low 56.3%

1200 x 150 x 19mm Class A ME1215-D .65 35-39 .89 White A Low 56.3%

SLT 600 x 600 x 19mm Class A ME4752-D .65 35-39 .89 White B Low 56.3%

1200 x 600 x 19mm Class A ME4753-D .65 35-39 .89 White B Low 56.3%

FL 600 x 600 x 19mm Class A ME4754-D .65 35-39 .89 White C Low 56.3%

1200 x 600 x 19mm Class A ME4755-D .65 35-39 .89 White C Low 56.3%

Olympia ii micrO ClimaPlus Panels.65 NRC

HRC

Low emitting performance meets CA Specification 01350 (CA Dept. of HealthServices Standard Practice for the testing of VOC emissions) and is listed onCHPS database for low-emitting materials. USG Certificate of Compliance for LowVOC Emissions) is available on request. Low emitting is defined as having less than0.009 mg/m3.

OLYMPIA II™ MICRO™ CLIMAPLUS™

Physical Data/Footnotes

<

Olympia II Micro™ ClimaPlus™ Information ESD Informationusgboral.com [email protected] [email protected]

Weight4.64 kg/m2

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.30m2 ˚C/W

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha soft brush or vacuum

InstallationShall not begin until the building is fullyenclosed, watertight, dry, permanent heating and cooling equipment is in operation, residual moisture from wet

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

trades (eg. terrazzo, concrete, plaster) has dissipated, and is free of chemical fumes. Do not mix production lots in the same ceiling area.

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14144. LR values are shown as averages

Grid ProfileOptions

A B C DX© DX Centricitee DXT

<

30 Year System Warranty– No visible sag

Reaction to Fire

Standard Flame Spread Smoke Developed ASTM E84 < 25 < 50 AS/NZS 3837 Group Number Classification : 1 unsprinklered ISO 5660 Parts 1 & 2 Group Number Classification : 1 - S

HRC

Legend

Low Emissions (VOC Class) ClimaPlus Performance High Recycled Content

Classified as low-emitting per standards established by the Lifetime system Warranty (maximum of 30 years) Classified as containing greater than 50% totalCollaborative for High-Performance Schools (CHPS), following to withstand conditions up to 40˚C/95%RH when recycled content. Total recycled content is based onCalifornia Specification 01350 testing methods. Low-emitting used with USG DONN suspension systems. panel composition of post-consumer and pre-consumeris defined as having less than 13.5 ppb. (0.017mg/m3) (post industrial) recycled content per FTC guidelines.

IM/4/12OMII/5-14New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid VOC Recycled Options Emissions Content

SQ 600 x 600 x 19mm Class A ME4750-D .65 35-39 .89 White A Low 56.3%

1200 x 600 x 19mm Class A ME4751-D .65 35-39 .89 White A Low 56.3%

SQ 1200 x 300 x 19mm Class A ME1230-D .65 35-39 .89 White A Low 56.3%

1200 x 150 x 19mm Class A ME1215-D .65 35-39 .89 White A Low 56.3%

SLT 600 x 600 x 19mm Class A ME4752-D .65 35-39 .89 White B Low 56.3%

1200 x 600 x 19mm Class A ME4753-D .65 35-39 .89 White B Low 56.3%

FL 600 x 600 x 19mm Class A ME4754-D .65 35-39 .89 White C Low 56.3%

1200 x 600 x 19mm Class A ME4755-D .65 35-39 .89 White C Low 56.3%

Olympia ii micrO ClimaPlus Panels.65 NRC

HRC

Low emitting performance meets CA Specification 01350 (CA Dept. of HealthServices Standard Practice for the testing of VOC emissions) and is listed onCHPS database for low-emitting materials. USG Certificate of Compliance for LowVOC Emissions) is available on request. Low emitting is defined as having less than0.009 mg/m3.

20 1 JUNE 2015 | CEILING TILE GUIDE NZ

Fine-textured panel

Olympia Micro™ ClimaPlus™

Advantages– Nondirectional pattern reduces installation time

and waste.– Economical, fine-textured panel.– Excellent light reflectance enhances indirect

lighting of a space.– ClimaPlus 30-year lifetime system warranty to

withstand conditions up to 40˚C/95% relative humidity without visible sag when used with a Donn® Brand suspension system.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Classrooms– Hotels– Reception and lobby areas– Restaurants– Retail stores– Offices

Substrate– Water-felted mineral fibre

olympia micro Panels with ClimaPlus Performance/

Donn Suspension System

ESD InformationRecycled Content: 52%

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

High Recycled Content

HRCOLYMPIA MICRO™ CLIMAPLUS™

Fine-textured panel

Mars™ ClimaPlus™

High-NRC

Advantages– Excellent noise reduction (NRC .80).– Fine, monolithic texture.– High light reflectance (LR .89).– Durable, scratch-resistant, cleanable surface.– Low maintenance panels look like new for

years to come.– ClimaPlus 30-year lifetime system warranty

against visible sag, mould and mildew.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Open-plan offices– Corridors– Department stores– Offices with indirect lighting– Reception areas and lobbies– Restaurants– Classrooms

Substrate– X-Technology mineral fibre

mars High-NRC with ClimaPlus Superior Performance/

Donn DX® Suspension System

ESD InformationRecycled Content: 76%ClimaPlus Superior Performance for Mould/Mildew

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

High Recycled Content

HRC

21CEILING TILE GUIDE NZ | 1 JUNE 2015

Physical Data/Footnotes

<

Olympia Micro™ ClimaPlus™ Information ESD Informationusgboral.com [email protected] [email protected]

Weight4.0-4.5 kg/m2 (15mm)5.0 kg/m2 (19mm)

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.25m2 ˚C/W (15mm)R 0.30m2 ˚C/W (19mm)

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha soft brush or vacuum

InstallationShall not begin until the building is fullyenclosed, watertight, dry, permanent heating and cooling equipment is in operation, residual moisture from wet

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

trades (eg. terrazzo, concrete, plaster) has dissipated, and is free of chemical fumes. Do not mix production lots in the same ceiling area.

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14144. LR values are shown as averages

Grid ProfileOptions

A B C DDX© DX Centricitee DXT Centricitee DXT

<

30 Year System Warranty– No visible sag

HRC

Legend

Low Emissions (VOC Class) ClimaPlus Performance High Recycled Content

Classified as low-emitting per standards established by the Lifetime system Warranty (maximum of 30 years) Classified as containing greater than 50% totalCollaborative for High-Performance Schools (CHPS), following to withstand conditions up to 40˚C/95%RH when recycled content. Total recycled content is based onCalifornia Specification 01350 testing methods. Low-emitting used with USG DONN suspension systems. panel composition of post-consumer and pre-consumeris defined as having less than 13.5 ppb. (0.017mg/m3) (post industrial) recycled content per FTC guidelines.

IM/4/1OM/5-14

Reaction to Fire

Standard Flame Spread Smoke Developed ASTM E84 < 25 < 50 AS/NZS 3837 Group Number Classification : 1 unsprinklered ISO 5660 Parts 1 & 2 Group Number Classification : 1 - S

New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Ecospecifier Global Green Tag Certified Device

Stacked Inline

Please note that while the devices are dispalyed and supplied as whole units they can be split and used as individual elements as shown below.

Stacked Inline

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid VOC Recycled Options Emissions Content

SQ 600 x 600 x 16mm Class A ME4211 .50 33-39 .87 White A Low 46-51%

1200 x 600 x 16mm Class A ME4411 .50 33-39 .87 White A Low 46-51%

SLT 600 x 600 x 16mm Class A ME4221 .50 33-39 .87 White B Low 46-51%

1200 x 600 x 16mm Class A ME4421 .50 33-39 .87 White B Low 46-51%

FLB 600 x 600 x 16mm Class A ME4231 .50 33-39 .87 White C Low 46-51%

1200 x 600 x 16mm Class A ME4431 .50 33-39 .87 White C Low 46-51%

SQ 600 x 600 x 19mm Class A ME4750 .60 33-39 .87 White A Low 61%

1200 x 600 x 19mm Class A ME4751 .60 33-39 .87 White A Low 61%

SLT 600 x 600 x 19mm Class A ME4752 .60 35-39 .87 White B Low 61%

1200 x 600 x 19mm Class A ME4753 .60 35-39 .87 White B Low 61%

FLB 600 x 600 x 19mm Class A ME4754 .60 35-39 .87 White C Low 61%

1200 x 600 x 19mm Class A ME4755 .60 35-39 .87 White C Low 61%

SLT 1200 x 600 x 19mm Class A ME4742 .50 35-39 .87 White B Low 61%

ILT 1200 x 600 x 19mm Class A ME4744 .50 35-39 .87 White D Low 61%

Olympia micrO ClimaPlus Panels.50 NRC

Olympia micrO ClimaPlus panels

.60 nrc

Olympia micrO ClimaPlus

Illusion Two/24Panels

HRC

Low emitting performance meets CA Specification 01350 (CA Dept. of HealthServices Standard Practice for the testing of VOC emissions) and is listed onCHPS database for low-emitting materials. USG Certificate of Compliance for LowVOC Emissions) is available on request. Low emitting is defined as having less than0.009 mg/m3.

OLYMPIA II™ MICRO™ CLIMAPLUS™

22 1 JUNE 2015 | CEILING TILE GUIDE NZ

Fine-textured panel

Rock Face® ClimaPlus™

Advantages– Specially compounded textured surface with hard core.– Perfect for increased abuse resistance and

sag resistance.– ClimaPlus 30-year lifetime system warranty to

withstand conditions up to 40˚C/95% relative humidity without visible sag when used with a Donn® brand suspension system.

– Firecode™ formulation for Fire Rated ceilings.

Grid Options

Donn DX 24mm

Applications– Athletic areas and exercise rooms– Schools– Corridors– Dormitory rooms– Gymnasiums– Courthouses

Substrate– Water-felted mineral fibre

Rock Face Panels with ClimaPlus Performance/

Donn DX/DXL Suspension System

ESD InformationRecycled Content: 49%

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

ROCK FACE® CLIMAPLUS™

23CEILING TILE GUIDE NZ | 1 JUNE 2015

<

Rock Face® ClimaPlus™ Information ESD Informationusgboral.com [email protected] [email protected]

Grid ProfileOptions

A Retention Clip Multiclip DX©/DXL™ 20428 PPM

Legend

Low Emissions (VOC Class) ClimaPlus Performance

Classified as low-emitting per standards established by the Lifetime system Warranty (maximum of 30 years)Collaborative for High-Performance Schools (CHPS), following to withstand conditions up to 40˚C/95%RH whenCalifornia Specification 01350 testing methods. Low-emitting used with USG DONN suspension systems.is defined as having less than 13.5 ppb. (0.017mg/m3)

<

30 Year System Warranty– No visible sag

Physical Data/Footnotes

Weight4.9 kg/m2

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.28m2 ˚C/W

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha soft brush or vacuum

Durability testASTM D1037: Tested to 23 kgf for a 6mm depression by a Janka ball.

ASTM D5420: Tested to 0.8kgf/m for impaction.

InstallationShall not begin until the building is fullyenclosed, watertight, dry, permanent heatingand cooling equipment is in operation,residual moisture from wet trades (eg.terrazzo, concrete, plaster) has dissipated,and is free of chemical fumes. Do not mixproduction lots in the same ceiling area.

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14144. LR values are shown as averages

Retaining Clips

Early Fire Performance

Index Ignitability Spread of Flame Heat Evolved Smoke Developed AS/NZS 1530.3 0 0 0 2 ASTM E84 – 25 – 50 AS/NZS 3837 Group 1 – unsprinklered

IM/4/12RF/5-14New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid VOC Anti-Mould Abuse- Recycled Min. Options Emissions & Mildew Resistant Content

SQ 1200 x 600 x 15mm ME56380 .50-.60 35 -39 .86 White A Low 49%

600 x 600 x 15mm ME56335 .50-.60 35 -39 .86 White A Low 49%

Rock Face ClimaPlus Panels

ROCK FACE® CLIMAPLUS™

24 1 JUNE 2015 | CEILING TILE GUIDE NZ

Clean Room™ ClimaPlus™

Advantages– Clean Room™ ClimaPlus™ Class 100 and Class

10M-100M panels have an embossed, vinyl-laminated face with sealed back and edges for use in Class 100 or 10M-100M clean rooms.

– FiReCode™ formulation for Fire Rated ceilings.– ClimaPlus 30-year lifetime system warranty to

withstand conditions up to 40˚C/95% relative humidity without visible sag when used with a donn® Brand suspension system.

Grid Options

Donn DX 24mm Donn DX 24mm - available with high performance antimicrobial coating

Applications– Clean rooms– Computer rooms– Emergency rooms– Kitchen/Food prep areas– Laboratories– Locker rooms– MRI rooms

Substrate– Water-felted mineral fibre

Clean Room Class 10M-100M Panels with ClimaPlus Performance/

donn DX Suspension System

ESD InformationRecycled Content: 51%ClimaPlus No-Sag Warranty

Smooth-textured panel, Class 100

Smooth-textured panel, Class 10M

-100M

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Lighting Design Daylight Lighting Noise Level Density for Levels Levels Reduction Reduction Disassembly

H H H H 3

High Recycled Content

HRCCLEAN ROOM™ CLIMAPLUS™

Fine-textured panel

Mars™ ClimaPlus™

High-NRC

Advantages– Excellent noise reduction (NRC .80).– Fine, monolithic texture.– High light reflectance (LR .89).– Durable, scratch-resistant, cleanable surface.– Low maintenance panels look like new for

years to come.– ClimaPlus 30-year lifetime system warranty

against visible sag, mould and mildew.

Grid Options

Donn DX 24mm Donn Certricitee 15mm

Applications– Open-plan offices– Corridors– Department stores– Offices with indirect lighting– Reception areas and lobbies– Restaurants– Classrooms

Substrate– X-Technology mineral fibre

mars High-NRC with ClimaPlus Superior Performance/

Donn DX® Suspension System

ESD InformationRecycled Content: 76%ClimaPlus Superior Performance for Mould/Mildew

H Contributes to Green Star points 3ESD additional advantages

IEQ Ene Mat

Increase Reduce Internal Low Volatile Lighting Design Daylight Lighting Noise Level Organic Low Mould Density for Levels Levels Reduction Compounds Formaldehyde Prevention Reduction Disassembly

H H H 3 3 3 H 3

High Recycled Content

HRC

25CEILING TILE GUIDE NZ | 1 JUNE 2015

Clean Room™ ClimaPlus™ Information ESD Informationusgboral.com [email protected] [email protected]

Grid ProfileOptions

A DX©/DXL™

Air flow barrier tape(by others)

Clean Room Panel

DONNDX Grid

Creating anAir Flow Barrier

30 Year System Warranty– No visible sag

Clean Room™ ClimaPlus™

Class 100

Clean Room™ ClimaPlus™

Class 10M - 100M

HRCHRC

Legend

ClimaPlus Performance High Recycled Content Lifetime system Warranty (maximum of 30 years) Classified as containing greater than 50% total to withstand conditions up to 40˚C/95%RH when recycled content. Total recycled content is based on used with USG DONN suspension systems. panel composition of post-consumer and pre-consumer (post industrial) recycled content per FTC guidelines.

HRC

Reaction to Fire

Standard Flame Spread Smoke Developed ASTM E84 < 25 < 50 AS/NZS 3837 Group 1 - sprinklered ISO 5660 Parts 1 & 2 Group Number Classification : 1 - S

CR/5-14New Zealand

0800 USGBORAL

Trademarks used herein belong to USGInteriors, LLC. or a related company

Australia: 1800 226 215

Edge Panel Size1,2 Class Item No NRC3 CAC3 LR4 Colour Grid Recycled Options Content

SQ 600 x 600 x 15mm ME56099 – 35-39 .79 White A 50.5%

1200 x 600 x 15mm ME56091 – 35-39 .79 White A 50.5%

SQ 600 x 600 x 15mm ME56060 .50 -.60 35-39 .79 White A 50.5%

1200 x 600 x 15mm ME56090 .50 -.60 35-39 .79 White A 50.5%

Physical Data/Footnotes

Weight5.4 kg/m2

EnvironmentalLimitations40˚C, 95% RH max.

Thermal ResistanceR 0.3m2 ˚C/W

Maximum Backloading0 kg/m2

MaintenanceCan be cleaned easily witha damp sponge, mild detergent and water. Do not use acetate, ammonia, or highly concentrated chlorine, bromide or other harsh chemicals.

InstallationShall not begin until the building is fullyenclosed, watertight, dry, permanent heatingand cooling equipment is in operation,residual moisture from wet trades (eg.terrazzo, concrete, plaster) has dissipated,and is free of chemical fumes. Do not mixproduction lots in the same ceiling area.

Safety First!Follow good safety and industrial hygiene practices during handling and installing of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.

Footnotes1. Not all panel sizes available in

all geographic areas2. Some imperial sizes available

to order3. Acoustic Test Standards NRC to ASTM C423 CAC to ASTM E14145. Field-cut edges of Clean Room

panels may be sealed with white latex paint.

CLEAN ROOM™ CLIMAPLUS™

26 1 JUNE 2015 | CEILING TILE GUIDE NZ

TECHNICAL DATA - CEILINGS

www.usgboral.com/novawhite PBPD44 201

Nova WhiteNova White is a 9mm white lay-in ceiling tile incorporating a High Density board with PVC laminate face and foil backing. The low sheen fine textured laminate facing reduces the visibility of blemishes and provides an easy surface to clean while the foil backing provides a condensation barrier limiting the possibility of tile sag and discoloration.

Nova White is suitable for commercial and retail applications where humidity or low ventilation roof spaces may be an issue.

ADVANTAGES• High quality laminate

• Ease of maintenance

• Improved sagging performance

• Low sheen finish

PERFORMANCE DETAILS Nova White was subjected to test procedures described in AS/NZS 3837:1998 “Method of test for heat and smoke release rates for materials and products using an oxygen consumption calorimeter’ for the purpose of determining the Group classifications in accordance with:

• National Construction Code (NCC) volume one specifications C1.10 and A2.4 of the Building Code of Australia (BCA).

• Fire tested to achieve the least fire hazard Group Number for ceiling materials as defined by BCA BRANZ ssessment No. FH 5205

INSTALLATIONRefer to USG Boral website www.usgboral.com or call TecASSIST® on

BOARD SPECIFICATION

Feature Description

Thickness 9mm

Sheet Size (width x length) 595 x 1 192mm

Edge Square edge

Packaging 6 Tiles per pack

Weight 5.30kg per unit 7.00kg per m2 (nominal)

Colour Matt finish (low sheen fine textured)

Grid Exposed

Finish - Face PVC laminate

Finish - Back Foil backing

Core High density Gypsum core

Fire Hazard Properties Group 1 - in accordance with BCA Specification C1.10a Fire Hazard Properties - Floors, Walls and Ceilings

Combustibility Non Combustible material as defined in BCA Deem-to-Satisfy Provisions C1.12

VOC Less than 0.5mg/m2 /hr

GECA N/A

Nova White

VOLATILE ORGANIC COMPOUNDS (VOC) AND FORMALDEHYDE MINIMISATIONUSG Boral Nova White has been independently tested to confirm compliance with Green Star specification limits for VOCs and formaldehyde. Emission Test Certificate CV130506.

REFERENCESRefer www.usgboral.com/novawhite for Material Safety Data Sheet, Volatile Organic Compound Emission details and Fire Test Report information. For Ceiling Tile range, refer to www.usgboral.com/ceilings

BORAL. All rights reserved. The trademarks USG BORAL, INNOVATION INSPIRED BY YOU and TecASSIST are trademarks of USG Boral Building Products or one or more of its affiliates.

This technical information is intended to provide general information on plasterboard products and should not be a substitute for professional building advice. We recommend you use a qualified person to install USG Boral plasterboard. Illustrations in this guide are only representative of USG Boral plasterboard products and the appearance and effects that may be achieved by their use. To ensure the information you are using is current, USG Boral recommends you review the latest building information available on the USG Boral website. www.usgboral.com

USG Boral Building Products Pty Limited – ABN 84 004 231 976 251 Salmon Street, Port Melbourne, Vic. 3207

SALES ENQUIRIES 0 8 0 0 U S G B o r a l (N Z )

BCC 13089 /201

Nova White

VOLATILE ORGANIC COMPOUNDS (VOC) AND FORMALDEHYDE MINIMISATIONUSG Boral Nova White has been independently tested to confirm compliance with Green Star specification limits for VOCs and formaldehyde. Emission Test Certificate CV130506.

REFERENCESRefer www.usgboral.com/novawhite for Material Safety Data Sheet, Volatile Organic Compound Emission details and Fire Test Report information. For Ceiling Tile range, refer to www.usgboral.com/ceilings

BORAL. All rights reserved. The trademarks USG BORAL, INNOVATION INSPIRED BY YOU and TecASSIST are trademarks of USG Boral Building Products or one or more of its affiliates.

This technical information is intended to provide general information on plasterboard products and should not be a substitute for professional building advice. We recommend you use a qualified person to install USG Boral plasterboard. Illustrations in this guide are only representative of USG Boral plasterboard products and the appearance and effects that may be achieved by their use. To ensure the information you are using is current, USG Boral recommends you review the latest building information available on the USG Boral website. www.usgboral.com

USG Boral Building Products Pty Limited – ABN 84 004 231 976 251 Salmon Street, Port Melbourne, Vic. 3207

SALES ENQUIRIES 0 8 0 0 U S G B o r a l (N Z )

BCC 13089 /201

NOVA WHITE

27CEILING TILE GUIDE NZ | 1 JUNE 2015

NOTES

28 1 JUNE 2015 | CEILING TILE GUIDE NZ

www.usgboral.comUSG Boral, the USG Boral Logo and usgboral.com, and Nova White are registered trade marks of USG Boral Australian Gypsum Ltd in Australia, other countries, or both. ClimaPlus, Mars, Impressions, Radar, Olympia II, Olympia, Eclipse, Rock Face, Clean Room are trademarks owned by USG Corporation or its subsidiaries, and used under license. If these and other USG Boral trade marks are marked on their first appearance in this information with trade mark symbols ( ® or ™

), these symbols indicate Australian registered or common law trade marks owned by USG Boral and others at the time this information was published. Such trade marks may also be registered or common law marks in other countries.

© Copyright USG Boral Building Products NZ 2015

This technical information is intended to provide general information on products and should not be a substitute for professional building advice. We recommend you use a qualified person to install USG Boral. Illustrations in this guide are only representative of USG Boral products and the appearance and effects that may be achieved by their use. To ensure the information you are using is current, USG Boral recommends you review the latest building information available on the USG Boral website. For further information contact TecASSIST® or your nearest USG Boral Sales Office.

www.usgboral.com