surveon nvr2100 spec-in guide
DESCRIPTION
Surveon NVR2100 Spec-in GuideTRANSCRIPT
Surveon NVR2100 Series Spec In Guide Line
Product & Marketing DepartmentSurveon Technology 2014
Ver.2.0 2014/9/5
Surveon NVR Solutions Overview2
EconomicSMB
Desktop Standalone
Embedded RAID NVR
ProfessionalStandard Project
EnterpriseMission Critical
Professional Hot Swappable
RAID NVR
Enterprise NVR Server Head
With Storage Subsystem
NVR2100 + iSCSI StorageSMR & NVR5000 SeriesNVR3000 Series
4 – 32 Channel
4, 8 HDD
4 – 64 Channel
4, 8, 12, 16 HDD
16 – 64 Channel
Up to 120 HDD
Entry – Mid Range
Retail, Hospitality, Super Market
SMB, Small School, Factory, Hotel
Mid Range
Public Utility, Government,
Education, Hotel, Factory, School
High End
Banking, Casino, Transportation
Air port, City Surveillance
Outline3
• Spec in business Flow
• Why subsystem storage?
• Subsystem Storage vs. all in one NVR
• Surveon NVR2100 solutions overview
• Surveon NVR2100 special features highlight
Spec in business flow.4
• Find out the potential competitors’ product spec.
• Get the unique features from Surveon NVR 2100
• Modify the features to the RFP with Surveon spec.
Surveon Spec In Flow and Sales Tools.5
CheckSurveon Special Features
Understand Surveon UniqueFeatures
Understand Surveon’s Special features and the benefits for the project
RAID Sub-system
Max.240 HDD
Controller Solutions Data Services
Get the Features from storage product datasheet
Select special features from Surveon NVR2100 & the subsystem storage.
Understand Competitors’Pros and Con s
Try to spec in the subsystem storage to create reliable and efficient security so-lutions for customers
Storage Subsystem vs.All in one NVR
Why storage subsystem is the basic requirement
for so many security projects?
6
Types of Storage Solutions7
Solutions Main Applications IO Performance Reliability Protection
PC Built In HDD Standard (Home, Office) Low Low None
Software RAID SMB, SOHO NAS Low – Middle Middle Middle
PC + RAID Card Purpose Build Server Middle Low-Middle High
SubsystemStorage
Data Intensive Professional
Project High High High
Solutions Overview for Video Storage8
Solutions Features Ref ProductApplication
Notes
PC Built In HDDNot Design for NVRI/O LoadingStorage Reliability
Dell PCSimple Application.
< 16 CH D1
SW RAID NAS SMB, Software RAID Synonlogy, QNAP NASLimited CH and IO
Performance
RAID CardSW RAID
Flexible, Integration effort, Function Rich Local SI, CTOS NVR
IntegrationInterference from
PC
Enterprise RAID Subsystem
HW RAIDHigh PerformanceI/O Storage, Capacity
Bosch, HoneywellMost Reliable
Solutions
9
Design Guide from AXIS
Quote from AXIS Applications Note, Page 31.http://www.axis.com/files/manuals/gd_ipsurv_design_32568_en_0807_lo.pdf
10
Reference Solutions – Security Company
BOSCH SecurityHW RAID Controller Storage
Honeywell SecurityHW RAID Controller Storage
11
Why SI partners chose Surveon
Surveon is the only supplier providing E2E solutions and
its own design full line enterprise storage subsystem.
Megapixel Camera RAID NVR Enterprise Video StorageVideo ManagementSoftware
Empower our partners with high quality enterprise
solutions at competitive cost.
Storage Subsystem vs. All in one NVR
12
13
Solutions for Megapixel Recording
Storage Subsystem Solutions All in one NVR
NVR Pool (Computing)
Storage Subsystem (Recording)
iSCSI/SASFiber
NVR built in HDD
NVR built in HDD
1. Once the PC failed, it will impact the storage.
2. The storage can not be shared with one another.
3. Thermal, vibration not optimized for storage.
14
What is Storage RAID Subsystem?
The RAID Storage subsystem is an dedicated system for server, PC
or NVR for data storage. It connected with the server through the
SAS, Fiber or the iSCSI interface. The controller based system with
a dedicated “RAID controller” provide the highest performance
and reliability for the mission critical applications like database,
banking, multimedia or security. The reference providers for
storage subsystem includes IBM, Dell, EMC, Infortrend or HP.
15
An overview for Storage Subsystem
3U 16 BAY RAID Storage Subsystem Standard short depth chassis
High Density Modules, Cable less Design Swappable Controller Module
16
What is all in one PC solutions?
One of the common solutions for NVR is to used a commercial off the
shelf solution to assemble the motherboard, chassis and the RAID card
into a complete systems. It is called CTOS based solutions. The benefits
for the CTOS are flexible and low cost. It’s also the only solution for
suppliers with neither design nor manufacturing capacity. The
disadvantages are integration risk and lack of reliability. Its storage
solutions come from a PC + RAID card. This all in one architecture brings
the low cost advantages but with lower reliability and performance
compared to the subsystem storage.
17
An overview for all in one NVR
3U Storage Server – Motherboard + Cable + Fan + RAID Card …
Concern on…
Dust
Cable
Thermal
Interference
Integration
Storage Subsystem vs. All in one Solution 18
Subsystem Storage All in one Solutions Pro and Con
System Architecture RAID Subsystem PC Built in When PC is down, so is the storage.
Overall Design Cable less, whole module
designed, anti-vibration and advanced thermal design
Cables, dusts, vibration and need to combine
thermal issues with CPU and HDD
HDD are prone to failure
Total HDD need less More Over Provisioning
Performance Enterprise RAID Subsystem RAID Card or software RAID
High performance and high stability
Maintenance Hot swappable hard disks, controller & central management, None or Difficult Lower maintenance
cost and risk
Scalability Yes None Costs on expansion
Occupied space Less than 1/3 Standard Save space
Data services Yes (Local, remote replication..) NO More Features
Size Standard short Rack Need the long depth rack Space & Cost
Power Lower power consumption Standard Save operation cost
Why spec in NVR2100 solutions?
19
20Projects with no Subsystem Storage spec in
Projects with no subsystem storage
Surveon Partners Competitors
Surveon All in one NVR Series Common All in one NVR
Use Surveon Standard E2E solutions to compete with the competitor’s solutions with
the SMR series. Leverage the standard VMS and camera spec in feature list for the
tender.
21
NVR2100 Solutions Spec In Flow
Spec in Subsystem Storage to the project
Surveon Partners Competitors
Use Surveon E2E products and RAID subsystem with high Integration, and proven E2E solutions. Competitive Cost from Surveon. Single contact support.
Need to obtain other storage solutions (IBM, EMC..) with higher costs, integration issues, unconfirm performance and other supporting issues.
Surveon Storage Subsystem Common All in one NVR
Increase 50% project winning rate
NVR2100 Solution Overview
22
NVR2100 series solution overview23
• Two Solutions: DAS Series & iSCSI Series
• Enterprise Storage Subsystem Solutions
• Easy Scalable solutions for hundreds channels
• Easy Scalable recording solutions
• Max. 960TB per NVR
• Built in Enterprise grade VMS
Selection Guide for NVR2100 Series24
Decide number of Channel for the Project
Calculate the storage capacity via Surveon design Tool
Decide the architecture: DAS (SAS) or SAN (iSCSI)
Choose the storage model from the price book
Easy Scalable for numerous camera channels
Easy Scalable for the storage capacity
1. NVR2100 Special Feature Overview
25
26Spec in Guide Line
Items Type Items Type
1 A 11 B
2 A 12 B
3 A 13 B
4 A 14 B
5 A 15 B
6 A 16 B
7 B 17 B
8 B 18 NA
9 B 19 NA
10 B 20 NA
If the project didn’t spec in the “storage subsystem” architecture. Partners can also use the features in type B to spec in the project and to use better specifications to compete with the all in one NVR solutions.
27
• The video recording device should use subsystem storage
through SAS/iSCSI/Fiber channel* connected with the NVR
server to provide a high performance and reliable megapixel
video recording”
1. Subsystem Storage Solutions
* Choose one from SAS/iSCSI/Fiber Channel
SAS cablesEthernet cablesEthernet switch
FC cablesFC Switch
SAS iSCSI FC
NVR NVR NVRNVR NVR NVR NVR NVR NVR
28
• The subsystem storage should be a hardware RAID controller
based solution (instead of the common PC, RAID card or Linux
software RAID solution to ensure system reliability.)
2. Controller Based Subsystem Storage
29
• All the main components for the system include power
supplier, RAID controller and the fan should be designed as
reliable modulate to support easy swappable and cable
less(without cable plug in/out).
3. Modulate and cable less design
30
• The system should support SAS expansion capability to support
at most 240 hard drives through the JBOD.
4. Storage Expandability
Storage RAID
JBOD
SAS
SAS
SAS
31
• The system should support iSCSI connectivity to support the
storage area network (SAN). Each controller supports 4 x 1GbE
iSCSI ports for video data in and out.
5. iSCSI Connectivity – When using for SAN
Ethernet cables
Ethernet switch
iSCSI
32
• The system should support the SAS 6G connectivity to provide
the maximum performance in the DAS topology. Each
controller supports 2 x SAS 6G ports for video data in and out.
6. SAS Connectivity – when using for DAS
SAS cables
SAS
NVR NVR NVR
33
• The system should support the 3.5” 6Gb/s SAS Hard Drive and
the 3.5” 6G/s SATA Hard Drive. It also supports the S.M.A.R.T
and the automatic bad sector assignment.
7. The Drive Connectivity
Serial Attached SCSI is a point to point serial protocol. It overwrites the older
parallel SCSI interface. SAS offers backward compatibility with SATA. The
SAS disk brings higher performance and reliability for most of the enterprise
applications. The common all in one NVR doesn’t support the SAS drive
34
• The system should support the RAID level 0, 1(0+1), 3, 5, 6, 10,
30, 50, 60 up to 32 logical drives and 64 partitions per logical
volume up to 1024 LUNs. It supports the on-line RAID
expansions and migrations.
8. RAID Configuration
P(2N-1, 2N)
1110
P(7,8)54
P(1,2)Disk 1
12P(9,10)
76
P(3,4)1
2N-1
Disk 2
P(11,12)98
P(5,6)32
2N
Disk 3
NBlocks
Striping with interspersed parity
RAID 5 Topology
35
• The system should in the 2U/3U, 19-inch rack mount form
factor. The depth of the chassis need to be limited under
520mm to make it fit in to the common surveillance rack in a
shorter depth.
9. Form Factors
Short depth chassis < 520mm
Common COTS Server, depth > 600mm
36
• The storage device should support the redundant power
supplier. And the power supplier need to be 80 PLUS-certified
delivering more than 80% energy efficiency
10. Power Supplier
37
• The NVR needs to offer an easy management tool through
network to handle account management, storage provisioning,
status, alarm monitoring and data services maintenance. The
management tool can support windows, Linux and MAC
platforms.
11. Management
38
• The NVR needs to offer an event notification tool based on
user configured methods and event sensitivities. Support
notification methods via email, SNMP , SMS. The events
include storage status, media error, abnormal recording
performance, disk error, RAID failure, abnormal hardware
status.
12. Alarm and Notification for Storage
39
• The NVR needs to support local replication in a remote virtual
point to record the data state at any given moment. This
enables NVR to restore the accidently deleted video.
13. Local Replication Snapshot – data services
Snapshot
ABC
ABD
Source
S0
S1
S0index
S0indexC
40
• The storage devices need to support or be certificated by
windows server 2012 (hyper –V), CITRIX , VMware , RedHat
Enterprise Linux, SUSE Linux to offer flexible deployment.
14. O.S. Support
41
• The system should support the sync or async full data copies
across systems. It is used for centralized data backup or the
disaster recovery.
15. Remote Replications
FC/iSCSI SAN
FC/iSCSI SAN WAN
FC/iSCSI SAN
FC/iSCSI SAN
Source Target Target
Primary Site Remote Site
42
• The NVR should support thin provisioning to dynamically
allocate the storage capacity when the data block are written.
It can reduce the storage capacity, prevent over provisioning
on disk and support the volume expansion without downtime.
16. Thin Provisioning – data services
43
• The system should support full redundant solutions to meet
the maximum reliability for power supplier and the RAID
controller.
17. Full Redundant architecture
44More Product Specifications Materials
45
Question & Answer