supreme complete guide structural elements · 1800 psa 180 2100 psa 210 2400 psa 240 2700 psa 270...

1
Supreme Benefits Constant accurate section cast in steel moulds Three smooth faces, brushed top face to key to masonry Packs banded on bearers for ease of handling PRESTRESSED LINTELS - FAIR FACED Length (mm) CODE 600 PSB 060 900 PSB 090 1050 PSB 105 1200 PSB 120 1350 PSB 135 1500 PSB 150 1800 PSB 180 2100 PSB 210 2400 PSB 240 2700 PSB 270 PSB 65 x 150mm Length (mm) CODE 600 PSD 060 900 PSD 090 1050 PSD 105 1200 PSD 120 1500 PSD 150 1800 PSD 180 2100 PSD 210 2400 PSD 240 2700 PSD 270 3000 PSD 300 3600 PSD 360 PSD 65 x 255mm Length (mm) CODE 600 PSC 060 900 PSC 090 1050 PSC 105 1200 PSC 120 1350 PSC 135 1500 PSC 150 1800 PSC 180 2100 PSC 210 2400 PSC 240 2700 PSC 270 3000 PSC 300 3600 PSC 360 PSC 65 x 215mm Length (mm) CODE 600 PSE 060 900 PSE 090 1050 PSE 105 1200 PSE 120 1350 PSE 135 1500 PSE 150 1650 PSE 165 1800 PSE 180 2100 PSE 210 2400 PSE 240 2700 PSE 270 3000 PSE 300 3300 PSE 330 3600 PSE 360 PSEA 140 x 100mm PSE 100 x 140mm Length (mm) CODE 600 PSA 060 750 PSA 075 900 PSA 090 1050 PSA 105 1200 PSA 120 1350 PSA 135 1500 PSA 150 1650 PSA 165 1800 PSA 180 2100 PSA 210 2400 PSA 240 2700 PSA 270 3000 PSA 300 3600 PSA 360 PSA 65 x 100mm MADE FROM SMOOTHCAST Manufacture size to order Section PSA PSB PSC PSD PSE PSEA Profile 65 x 100 65 x 150 65 x 215 65 x 255 100 x 140 140 x 100 CLEAR SPAN Service Moment (kN/m) 0.36 0.44 0.60 1.36 1.37 2.23 600 300 11.76 12.07 22.27 27.78 39.33 50.44 *750* 450 8.00 9.05 16.70 20.83 29.50 37.83 900 600 5.12 6.26 8.53 16.67 19.48 30.27 1050 750 3.56 4.35 5.93 13.43 13.53 22.02 1200 900 2.61 3.19 4.35 9.87 9.94 16.18 *1350* 1050 2.00 2.44 3.33 7.56 7.61 12.39 1500 1200 1.58 1.93 2.63 5.97 6.01 9.79 *1650* 1350 1.28 1.56 2.13 4.48 4.87 7.93 1800 1500 1.06 1.29 1.76 4.00 4.03 6.55 2100 1650 0.89 1.09 1.48 3.36 3.38 5.51 2100 1800 0.76 0.93 1.26 2.86 2.88 4.69 2400 1950 0.65 0.80 1.09 2.47 2.49 4.05 2400 2100 0.57 0.70 0.95 2.15 2.16 3.52 2700 2250 0.50 - 0.83 1.89 1.90 3.10 2700 2400 0.44 - 0.74 1.67 1.69 2.74 *3000* 2550 0.40 - 0.66 1.49 1.50 2.45 *3000* 2700 0.35 - 0.59 1.34 1.35 2.20 *3300* 2850 0.32 - 0.53 1.21 1.22 1.98 *3300* 3000 0.29 - 0.48 1.10 1.10 1.80 *3600* 3150 0.26 - 0.44 1.00 1.01 1.64 *3600* 3300 0.24 - 0.40 0.91 0.92 1.50 LOAD/SPAN TABLE - Uniformly distributed service loads (kN/m) The self weight of the lintel must be subtracted from the load given Please Note! Clear spans shown are in increments of 150mm and the safe working loads indicated are based on the clear span plus 150mm of bearing each end. Our lintels are supplied in a standard range of lengths and can be cut to length as required. The safe working load per metre is the least of the flexural strength, the shear strength or the load that gives a deflection limit of L/325. Deflection information is available for our full range of lintels, please see Supreme DoP or contact our technical department. Lengths indicated *----* are not available in all section sizes SUPREME COMPLETE GUIDE STRUCTURAL ELEMENTS www.supremeconcrete.co.uk

Upload: truongdieu

Post on 25-Apr-2018

221 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: SUPREME COMPLETE GUIDE STRUCTURAL ELEMENTS · 1800 PSA 180 2100 PSA 210 2400 PSA 240 2700 PSA 270 3000 PSA 300 3600 PSA 360 PSA 65 x 100mm ... SUPREME COMPLETE GUIDE STRUCTURAL ELEMENTS

Supreme Benefits• Constant accurate section cast in steel moulds

• Three smooth faces, brushed top face to key to masonry

• Packs banded on bearers for ease of handling

PRESTRESSED LINTELS - FAIR FACED

Length(mm)

CODE

600 PSB 060

900 PSB 090

1050 PSB 105

1200 PSB 120

1350 PSB 135

1500 PSB 150

1800 PSB 180

2100 PSB 210

2400 PSB 240

2700 PSB 270

PSB65 x 150mm

Length(mm)

CODE

600 PSD 060

900 PSD 090

1050 PSD 105

1200 PSD 120

1500 PSD 150

1800 PSD 180

2100 PSD 210

2400 PSD 240

2700 PSD 270

3000 PSD 300

3600 PSD 360

PSD65 x 255mm

Length(mm)

CODE

600 PSC 060

900 PSC 090

1050 PSC 105

1200 PSC 120

1350 PSC 135

1500 PSC 150

1800 PSC 180

2100 PSC 210

2400 PSC 240

2700 PSC 270

3000 PSC 300

3600 PSC 360

PSC65 x 215mm

Length(mm)

CODE

600 PSE 060

900 PSE 090

1050 PSE 105

1200 PSE 120

1350 PSE 135

1500 PSE 150

1650 PSE 165

1800 PSE 180

2100 PSE 210

2400 PSE 240

2700 PSE 270

3000 PSE 300

3300 PSE 330

3600 PSE 360

PSEA140 x 100mm

PSE100 x 140mm

Length(mm)

CODE

600 PSA 060

750 PSA 075

900 PSA 090

1050 PSA 105

1200 PSA 120

1350 PSA 135

1500 PSA 150

1650 PSA 165

1800 PSA 180

2100 PSA 210

2400 PSA 240

2700 PSA 270

3000 PSA 300

3600 PSA 360

PSA65 x 100mm

MADE FROM SMOOTHCAST

Manufacture size

to order

Section PSA PSB PSC PSD PSE PSEA

Profile 65 x 100 65 x 150 65 x 215 65 x 255 100 x 140 140 x 100

CLEAR SPANService Moment (kN/m)

0.36 0.44 0.60 1.36 1.37 2.23

600 300 11.76 12.07 22.27 27.78 39.33 50.44

*750* 450 8.00 9.05 16.70 20.83 29.50 37.83

900 600 5.12 6.26 8.53 16.67 19.48 30.27

1050 750 3.56 4.35 5.93 13.43 13.53 22.02

1200 900 2.61 3.19 4.35 9.87 9.94 16.18

*1350* 1050 2.00 2.44 3.33 7.56 7.61 12.39

1500 1200 1.58 1.93 2.63 5.97 6.01 9.79

*1650* 1350 1.28 1.56 2.13 4.48 4.87 7.93

1800 1500 1.06 1.29 1.76 4.00 4.03 6.55

2100 1650 0.89 1.09 1.48 3.36 3.38 5.51

2100 1800 0.76 0.93 1.26 2.86 2.88 4.69

2400 1950 0.65 0.80 1.09 2.47 2.49 4.05

2400 2100 0.57 0.70 0.95 2.15 2.16 3.52

2700 2250 0.50 - 0.83 1.89 1.90 3.10

2700 2400 0.44 - 0.74 1.67 1.69 2.74

*3000* 2550 0.40 - 0.66 1.49 1.50 2.45

*3000* 2700 0.35 - 0.59 1.34 1.35 2.20

*3300* 2850 0.32 - 0.53 1.21 1.22 1.98

*3300* 3000 0.29 - 0.48 1.10 1.10 1.80

*3600* 3150 0.26 - 0.44 1.00 1.01 1.64

*3600* 3300 0.24 - 0.40 0.91 0.92 1.50

LOAD/SPAN TABLE - Uniformly distributed service loads (kN/m)The self weight of the lintel must be subtracted from the load given

Please Note! Clear spans shown are in increments of 150mm and the safe working loads indicated are based on the clear span plus 150mm of bearing each end.

Our lintels are supplied in a standard range of lengths and can be cut to length as required.

The safe working load per metre is the least of the flexural strength, the shear strength or the load that gives a deflection limit of L/325.

Deflection information is available for our full range of lintels, please see Supreme DoP or contact our technical department.

Lengths indicated *----* are not available in all section sizes

SUPREME COMPLETE GUIDE STRUCTURAL ELEMENTS www.supremeconcrete.co.uk