supplier quality engineering/receiving and inspection first ......p-389, rev. 03 – page 1 of 9 l3...
TRANSCRIPT
P-389, Rev. 03 – Page 1 of 9 L3 Proprietary. Printed versions of this document are considered obsolete.
Supplier Quality Engineering/Receiving and Inspection – First Article Verification
Procedure – Level II Document Number: P-389
Revision: 03 Effective Date: 10/21/2019
Point of Contact: Dan Anderson Title: Manager, Supplier Quality Engineering
Requirements: AS9100 : 8.5.1.3; AS9102
TABLE OF CONTENTS
PURPOSE & SCOPE ............................................................................................................................................................................ 1
ACRONYMS, TERMS, & DEFINITIONS ................................................................................................................................................ 1
PROCEDURE ...................................................................................................................................................................................... 2
1. FIRST ARTICLE INSPECTION REPORT REQUIREMENTS .............................................................................................................. 2
2. FIRST ARTICLE INSPECTION REPORT VERIFICATION ON-SITE AT SUPPLIER .............................................................................. 3
3. FIRST ARTICLE INSPECTION REPORT VERIFICATION AT CSW .................................................................................................... 4
4. FIRST ARTICLE INSPECTION REPORT VERIFICATION STEPS ....................................................................................................... 4
RECORDS ........................................................................................................................................................................................... 8
DOCUMENT INFORMATION .............................................................................................................................................................. 9
PURPOSE & SCOPE
A First Article Inspection (FAI) will be completed by L3 Communication Systems – West (CSW) Suppliers on supplied production hardware when required according to AS9102. The following steps outline the proper process for verifying that a First Article Inspection Report (FAIR) completed by Suppliers is compliant to FAI requirements. This document is intended for BCS Receiving Inspector, Inspection Technicians and Supplier Quality Engineering (SQE) personnel who participate in First Article verifications and reviews.
ACRONYMS, TERMS, & DEFINITIONS
ATS – Authorization to Ship
BOM – Bill of Material
C of C – Certificate of Conformance
Conditionally Required – Information that shall be completed in AS9102 forms when applicable to product or when required by the Customer
COTS – Commercial Off The Shelf
Design Characteristics – Those dimensional, visual, functional, mechanical, and material features or properties, which describe and constitute the design of the article as specified by drawing requirements
EC – Enterprise Change
FAI – First Article Inspection
FAIR – First Article Inspection Report
Initial First Article Inspection – The initial First Article Inspection that is performed on a part
Inspection Point – A buyoff, data collect, or operation that is associated with drawing characteristics to be inspected to complete First Article requirements
MOTS – Modified Off The Shelf
Optional – Information that can be included by Suppliers in AS9102 forms for clarification or convenience, but is not explicitly required by CSW
P-389, Rev. 03 – Page 2 of 9 L3 Proprietary. Printed versions of this document are considered obsolete.
Partial First Article Inspection – A First Article Inspection completed after the initial First Article that addresses differences between the current configuration and prior approved configurations. Partial FAIRs are also used when parts lists are updated, manufacturing processes have been modified, manufacturing location has been moved, or the addition of alternative part numbers. Also known as a “delta” FAI.
PO – Purchase Order
PCD – Procurement Control Drawing
Required – Mandatory information that shall be included in First Article Documentation (Forms 1, 2, and 3)
SCD – Source Control Drawing
VICD – Vendor Item Control Drawing
PROCEDURE
1. FIRST ARTICLE INSPECTION REPORT REQUIREMENTS
1.1 The requirement for a Supplier to perform an FAI on a product will be communicated via the Purchase Order (PO) in the form of a Quality Clause.
On-site FAI Verification at the Supplier: For this requirement, the CSW SQE travels to the Supplier’s facility and validates the Supplier’s FAIR on-site. Based on the cost of the product, the Supplier’s performance rating, and other factors, the SQE (or authorized individual) may waive the on-site FAI and have the Supplier ship the FAIR with the product for verification at CSW. Only the SQE (or authorized individual) has the authority to waive the on-site FAI.
FAI Verification at CSW: For this requirement, the Supplier performs an FAI and ships the FAIR with the product for verification at CSW.
1.2 First Article Inspection by drawing type
1.2.1 Commercial Off The Shelf (COTS) items are identified with a Vendor Item Control Drawing (VICD) type and do not require an FAI.
1.2.2 Modified Off The Shelf (MOTS) items are identified with a Procurement Control Drawing (PCD) type and shall be evaluated by the appropriate SQE to determine if an FAI is required.
PCD type parts require an FAI if the drawing includes the word “modified” at the bottom of the title block as shown in Figure 1. The inclusion of the word “modified” in that location signifies that Note 3 exists within the drawing notes section and a corresponding superscript 3 is called out on a feature, item, or table in the drawing. If the word “modified” is not shown at the bottom of the title block, then no FAI is required.
Figure 1 – “Modified” notation example
1.2.3 Source Control Drawing (SCD) types always require an FAI.
1.3 Figure 2 illustrates the decision steps to determine if a specific PO requires an FAI.
P-389, Rev. 03 – Page 3 of 9 L3 Proprietary. Printed versions of this document are considered obsolete.
Figure 2 – FAI Decision Process Flow
2. FIRST ARTICLE INSPECTION REPORT VERIFICATION ON-SITE AT SUPPLIER
2.1. FAIR verification on-site at a Supplier shall only be completed by an SQE (or authorized individual) who has been trained to the requirements of AS9102 as well as to this procedure.
2.2. Upon successful completion of the FAIR verification, the SQE (or authorized individual) shall sign the AS9102 Form 1, Block 23 and date Block 24 to certify their acceptance of the FAIR.
2.3. The SQE (or authorized individual) completes the Authorization to Ship (ATS) form and provides it to the Supplier.
2.4. The Supplier shall include the signed FAIR with the shipment of the product to CSW.
2.5. Upon receipt of the FAIR at CSW, the Inspector shall verify that Blocks 23 and 24 of AS9102 Form 1 are signed and dated by an SQE (or authorized individual).
2.6. The Inspector shall record the FAIR in the FAI log.
2.7. The Inspector shall place the FAIR in the Quality Records basket for electronic storage via scanning.
FAI Process: FAIR Verification On-site at Supplier
SQE
Sup
plie
rR
I
StartNotifies Buyer/SQE FAI is ready
End
SQE schedules on site FAI
SQE completes review of FAI at
Supplier
FAI Acceptance
No
Yes
Signs Form 1 Block 23 & 24, Completes ATS
Form
Corrects FAIShips Parts to BCS
with the signed FAIR
Verify Form 1 Block 23 & 24 are signed and dated
Record FAIR in FAI Log, put FAIR in basket for QA
Records
Figure 3 - FAI Process: FAIR Verification On-site at Supplier
P-389, Rev. 03 – Page 4 of 9 L3 Proprietary. Printed versions of this document are considered obsolete.
3. FIRST ARTICLE INSPECTION REPORT VERIFICATION AT CSW
3.1. FAIR verification shall only be completed by an Inspector, Technician, or SQE who has been trained to the requirements of AS9102 as well as to this procedure.
3.2. Inspectors and Technicians shall verify all FAIR attributes that are within the scope of their personal knowledge base. Inspectors and Technicians shall contact the appropriate SQE if the FAIR contains attributes outside their current knowledge level. The applicable SQE shall work directly with the Inspector or Technician to verify material compliance to the drawing and Bill of Material (BOM).
3.3. Upon successful completion of the FAIR verification, the Inspector, Technician, or SQE shall sign the AS9102 Form 1, Blocks 23 and date Block 24 to certify their acceptance of the FAIR.
3.4. The Inspector, Technician, or SQE shall record the FAIR in the FAI log.
3.5. The Inspector, Technician, or SQE shall place the FAIR in the Quality Records basket for electronic storage via scanning.
FAI Process: FAIR Verification at CSW
SQE
Sup
plie
rA
S91
02
Cer
tifi
ed R
I
Start
End
Ships Parts to CSW with the
FAIR
Verify FAIR content
Record FAIR in FAI Log, put FAIR in basket for QA
Records
FAI within scope of
knowledge base
Complete FAIR verification
Yes
Complete FAIR verification
No
Record FAIR in FAI Log, put FAIR in basket for QA
Records
FAI Acceptance
FAI AcceptanceSign Form 1 Block
23 & 24
Sign Form 1 Block 23 & date Block
24
Yes
No Corrects FAI
No
Yes
Figure 4 - FAI Process: FAIR Verification at CSW
4. FIRST ARTICLE INSPECTION REPORT VERIFICATION STEPS
The following are detailed instructions on how to thoroughly review and verify a FAIR for completeness and accuracy. A physical part must be used to perform a valid FAIR verification.
4.1. General
4.1.1. Verify that all required sections of the FAIR are complete, in English.
4.1.2. Verify the material number and revision on the FAIR match the material number and revision of the physical part as well as the material number and revision of the PO.
4.1.3. Verify all design characteristics (dimensions, finish, etc.), notes, and BOM items are accounted for in the FAIR and are within specification. Compliant FAI documentation should contain actual data to verify conformance to the print characteristic and note requirement. It is not required, but highly recommended that the Supplier include a design characteristic accountability sheet (ballooned drawing) in conjunction with AS9102 Form 3 in the FAIR for location and print requirement information. Print characteristics labeled as “Reference” or “Reference Designators” are intended for informational purposes only and are not required to be ballooned or entered on FAIR.
4.1.4. Items that cannot be verified due to the product already being assembled are considered acceptable based on the Supplier’s Certificate of Conformance (C of C).
4.2. AS9102 Forms
4.2.1. Form 1, Part Number Accountability
P-389, Rev. 03 – Page 5 of 9 L3 Proprietary. Printed versions of this document are considered obsolete.
Note: FAI form blocks (except blocks 23 & 24) will be filled by the Supplier designee with detailed information. One entry may be made for each column/row. Optional or Conditionally Required blocks may be left blank or filled with “N/A.”
Table 1 - Fields Required for AS9102 Form 1
Form Location Inspection Action Form Definition Example
Block 1 Required Part Number/ Material Number ex. 1000382717
Block 2 Required Part Name ex. SUPPORT, BLANK SIDE, NBA GND
Block 3 Conditionally required Serial Number ex. 325
Block 4 Conditionally required FAI Report Number ex. FA 08753
Block 5 Conditionally required Part Revision Level ex. REV. A
Block 6 Conditionally required Drawing Number ex. 1000382717
Block 7 Conditionally required Drawing Revision Level ex. REV. A
Block 8 Conditionally required Additional Changes ex. 15789
Block 9 Required Manufacturing Process Reference ex. 10267814
Block 10 Required Organization name ex. CSW
Block 11 Optional Supplier Cage Code, or Supplier Identification Number
ex. 06401
Block 12 Optional Purchase Order Number ex. 4500011100
Block 13 Required Detail FAI, Assembly FAI checkboxes ex. Check in applicable box (see section 2.2.1.1, 2.2.1.2)
Block 14 Required Full FAI, Partial FAI checkboxes ex. Check in applicable box (see section 2.2.1)
Block 15 Conditionally required (Required when block 13 Assembly FAI is checked)
Part Number ex. 60055828-001 or Material Number
Block 16 Conditionally required (Required when block 13 Assembly FAI is checked)
Part Name ex. CCA – Antenna LNA KU-BAND (not used, alternate item)
Block 17 Conditionally required (Required when block 13 Assembly FAI is checked and part is serialized)
Part Serial Number ex. 1345
Block 18 Conditionally required FAI Report Number ex. FA 03254
Block 19 Required Signature ex. Inspector’s signature, electronic signature or stamp, John Q. Inspector
Block 20 Required Date ex. dd-mm-yy (format not important)
Block 21 Optional Reviewed By ex. Reviewer’s signature, electronic signature or stamp, Jane I. Quality
Block 22 Optional /only required if block 21 is signed
Date ex. dd-mm-yy (format not important)
Block 23 Required: Shall be signed by authorized CSW Inspector, Technician, or Supplier Quality Engineer
Customer Approval ex. Customers signature, electronic signature or stamp, Jane I. Quality
P-389, Rev. 03 – Page 6 of 9 L3 Proprietary. Printed versions of this document are considered obsolete.
Table 1 - Fields Required for AS9102 Form 1
Block 24 Required: Shall be dated by Block 23 Signee
Date ex. dd-mm-yy (format not important)
4.2.1.1. Verify FAI Type (Block 13) – Verify FAI type for detail piece part or assembly.
4.2.1.1.1. Detail FAI – used for a single piece part that contains no additional components or subassemblies. Primarily used for a piece part with detailed dimensional and processing requirements.
4.2.1.1.2. Assembly FAI – used for assemblies that includes a BOM for a set of components or subassemblies. The Assembly FAI verification is to be performed on those characteristics specified on the assembly drawing.
4.2.1.2. Verify FAI type (block 14) – Full or Partial.
4.2.1.2.1. Initial First Article Inspections require the checkbox “Full” FAI to be checked in Block 14.
4.2.1.2.2. Partial First Article Inspections require the checkbox “Partial” to be checked in Block 14.
The “Baseline Material Number (including revision level)” and “Reason for Partial FAI” (block 14), will be filled out by the Supplier for a partial FAI only. The baseline material number including revision level is the material number and revision level of the most recent FAI for that material number. The EC(s) that is to be accounted for with the partial FAI should be referenced under the “Reason for Partial FAI” block along with a short description of the change.
4.2.1.2.3. If the change does not affect hardware part(s) listed on the PO, it is permitted to submit only Form 1 stating in Field 14 the reason for Partial FAI.
4.2.1.3. Verify all subassembly parts (blocks 15-17)
4.2.1.3.1. Blocks 15-17 are only completed when the FAIR is for an assembly with lower level subassemblies. Verify the Material Numbers, Names and Serial Numbers as applicable of the items that make up the assembly.
4.2.1.3.2. Verify all serialized items are accounted for by the Supplier individually in blocks 15-17.
4.2.1.3.3. It is acceptable to attach the parts list to the FAIR to account for non-serialized items, in lieu of listing them individually, as long as the attached list is referenced in Block 15.
4.2.1.4. Verify if the FAI is complete (block 19)
4.2.1.4.1. Checkbox “FAI complete” or “FAI not complete” must be checked by the Supplier based on whether or not the FAI is complete or has a nonconformance or non-verified characteristic that will require an additional Partial FAI to address.
4.2.1.4.2. If the FAIR is marked as “FAI not complete,” the CSW SQE shall be notified immediately to begin the process of flagging the material as rejected at initial FAI so that a Partial FAI will be required on next release.
4.2.2. Form 2, Product Accountability – Materials, Special Processes, and Functional Testing
This form is intended to detail any material, special processes (per AS9100 and ISO 9000 Standards), or functional testing that are defined as Design Requirements (e.g. plating, finishing or painting listed on the drawing, testing requirements, etc.).
Note: FAI form blocks will be filled by the Supplier designee with detailed information. One entry may be made for each column/row. Optional or Conditionally Required blocks may be left blank or filled with “N/A.”
P-389, Rev. 03 – Page 7 of 9 L3 Proprietary. Printed versions of this document are considered obsolete.
Table 2 - Fields Required for AS9102 Form 2
Form Location Inspection Action Form Definition Example
Block 1 Required Part Number/ Material Number
ex. 1000382717
Block 2 Required Part Name ex. SUP SIDE, NBA GND PORT, BLANK
Block 3 Conditionally required Serial Number ex. 325
Block 4 Conditionally required FAI Report Number ex. FA 08753
Block 5 Conditionally required Material or Process Name ex. OP 0200
Block 6 Conditionally required Specification Number ex. WS-010, REV 10
Block 7 Optional Code ex. 210
Block 8 Conditionally required Special Process Supplier Cage Code
ex. 05031
Block 9 Conditionally required Customer Approval Verification
ex. Yes/No/NA
Block 10 Conditionally required Certificate of Conformance number
ex. 40068689741
Block 11 Conditionally required Functional Test Procedure Number
ex.TP 60002021 Rev F
Block 12 Conditionally required Acceptance report number, If applicable
ex. 198-20
Block 13 Optional Comments ex. Such as: “Non blue print required torque values controlled in BOP 1000097471”
Block 14 Required Signature ex. Prepared by signature, electronic signature or stamp, John Q. Inspector
Block 15 Required Date ex. dd-mm-yy (format not important)
4.2.2.1. Special Processes – if special processes are defined as a design characteristic:
4.2.2.1.1. Verify block 6 includes the specification and revision for special process (ex. WS-010, REV 10, for outside finish operation).
4.2.2.1.2. Verify that Supplier Cage Code or supplier name of who performed the special processes or supplying material is recorded in block 8.
4.2.2.1.3. Verify the Certification Number in block 10 match the number on the C of C documents (i.e. plating, finishing or painting listed on the drawing, testing requirements, etc.).
4.2.3. Form 3, Characteristic Accountability, Verification, and Compatibility Evaluation
This form is intended to detail and record print location and design characteristic information as well as the Supplier’s inspection data of the designated first article part.
Note: FAI form blocks will be filled by the Supplier designee with detailed information. One entry may be made for each column/row. Optional or Conditionally Required blocks may be left blank or filled with “N/A.”
P-389, Rev. 03 – Page 8 of 9 L3 Proprietary. Printed versions of this document are considered obsolete.
Table 3 - Fields Required for AS9102 Form 3
Form Location Inspection Action Form Definition Example
Block 1 Required Part Number/ Material Number
ex. 1000382717
Block 2 Required Part Name ex. SUPPORT, BLANK SIDE, NBA GND
Block 3 Conditionally required Serial Number ex. 325
Block 4 Conditionally required FAI Report Number ex. FA 08753
Block 5 Required Characteristic number ex. 13 (indicating bubble 13)
Block 6 Conditionally required Reference Location (characteristic location, drawing zone, page, location, etc.)
ex. 1C3 or Note 4, (sheet 1 zone C3)
Block 7 Conditionally required Characteristic Designator (Key characteristic, etc.)
ex. Note 4 or A3 (Reference Designator)
Block 8 Required Requirement exactly as stated on the print
ex. Dim. 6.55 +/- .03, 3X Note 2
Block 9 Required Inspection Results. Visually inspected characteristics are to be noted with a statement of either acceptance or rejection
ex. 6.57, Accept
Block 10 Conditionally required Designed Tooling (Tool asset # used to validate the requirement).
Ex. CMM prog. #41863, Functional gauge #25
Block 11 Conditionally required Nonconformance Number ex. IN213682
Block 12 Required Prepared by ex. Prepared by signature, electronic signature or stamp, John Q. Inspector
Block 13 Required Date ex. dd-mm-yy (format not important)
Block 14 Optional Any additional relevant comments or specifications
Additional Data / Comments: This area is reserved for optional fields; ex. IS-008 or torques spec 60083155 (Can be used for applicable comments and or conformance specification information)
RECORDS
Identification Completed First Article Inspection Reports Storage Hard copy records are scanned and stored by Quality Records. Electronic records are stored in SAP. Protection Electronic records are protected by regular backups performed by the IT department. Hard
copy records are stored in a locked room with limited access.
Retrieval Electronic records can be retrieved via SAP. Any hard copy data that may be available is obtained from Quality Records.
Retention Time Hard copy records are stored by Quality Records for 1 year per FAR 4.703 requirements. Electronic records stored in SAP are retained indefinitely.
Disposition Hard copy records will be disposed of by the Quality Records team. Electronic records N/A.
END OF DOCUMENT
P-389, Rev. 03 – Page 9 of 9 L3 Proprietary. Printed versions of this document are considered obsolete.
DOCUMENT INFORMATION
Responsible Organization: Quality
Function/Sub-function: Supplier Quality Engineering
Governing Document(s): P-046, Receiving Inspection P-413, First Article Inspection Planning AS9102, Aerospace Standard, First Article Inspection Requirement
Subordinate Document(s): N/A
Related Document(s): N/A
Related Training: FAI 100: First Article Inspection Training
Approval Requirements: Business Change Control Board Chair Quality Business Change Control Board Representative Manager, Supplier Quality Engineering Manager, Receiving Inspection
Review Requirements: Director, Supplier Quality Engineering Manager, Component Engineering
Revision History Summary
Revision # Description of Change Date
00 Initial release 3/4/2019
01 Updated records protection, retrieval and disposition information in the Records table.
4/18/2019
02 Changed L3T to CSW throughout. Added acronym and definition for COTS and MOTS. In section 1.3, changed “required” to “not required but highly recommended”. Rewrote section 1.4 to clarify verification process. Added new section 1.6 for First Article Inspection of COTS/MOTS Material and renumbered rest of sections accordingly. Updated Form Definition and Example for Block 19 and 21 in Table 1. Updated Form Definition and Example for Block 14 in Table 2. Updated Inspection Action for Block 5 in Table 3. Updated Form Definition and Example for Block 12 in Table 3. Added “electronic signature or stamp” in section 2.6.1. Removed “Teamcenter and SAP” as the storage in section 2.6.3. Added “the Quality Records” in section 2.6.3. Updated FAI Flowchart. Removed “Teamcenter” from the storage and retrieval information in the Records table. Added Figure numbers.
7/30/2019
03 Complete restructuring of the document – sections, flowcharts, and content. 10/21/2019