super span alcantarillas
TRANSCRIPT
MODELO LUZ LUZ EN FLECHA AREA PERIMETRO RADIO DEm BASE m m2 N TAPA
m m
238A5 5.91 5.83 2.06 9.75 33 3.99238A6 6.11 6.05 2.28 11.19 35 3.99258A6 6.56 6.50 2.36 12.39 37 4.34268A6 6.78 6.72 2.40 13.01 38 4.52278A6 7.01 6.94 2.44 13.65 39 4.69
288A6 7.23 7.17 2.49 14.29 40 4.86298A6 7.46 7.39 2.53 14.95 41 5.04308A6 7.68 7.62 2.57 15.62 42 5.21318A6 7.91 7.84 2.61 16.30 43 5.39318AB 8.31 8.26 3.04 20.11 47 5.39
338A7 8.56 8.50 2.91 19.68 47 5.74338A8 8.76 8.71 3.12 21.71 49 5.74348A7 8.78 8.73 2.95 20.45 48 5.91368A7 9.23 9.17 3.03 22.03 50 6.26368AB 9.43 9.38 3.24 24.20 52 6.26
378A7 9.45 9.40 3.07 22.84 51 6.44368A10 9.63 9.50 3.69 28.69 56 6.26398A7 9.68 9.62 3.11 23.66 52 6.61378A10 9.85 9.72 3.74 29.65 57 6.44388A10 10.08 9.95 3.78 30.62 58 6.61
398A8 10.10 10.06 3.37 26.81 55 6.79398A11 10.50 10.38 4.03 34.09 61 6.79418A8 10.55 10.51 3.45 28.60 57 7.13428A8 10.78 10.73 3.49 29.52 58 7.31418A14 11.55 11.46 4.76 44.30 69 7.13
428A14 11.77 11.69 4.80 45.51 70 7.31
NOTAS:• Las dimensiones (diámetro luz flecha área) son tomadas a la cresta interna de
la corrugación.• Son disponibles bajo pedido tamaños mayores e intermedios• Para determinar la periferia total en metros multiplicar el valor N por 0.2438• Las longitudes de las estructuras son valores múltiplos de 6 y 8 pies.• La altura de la cobertura máxima no dependegeneralmente de las condiciones
de carga viva.• El diseño estructural deberá tomar en cuenta las cargas vivas cuando:
- Carreteras:altura de cobertura menor de 2.5 m- Vías férreas: altura de cobertura menor de 9.0 m
• Paracargas vivas E-80 o equivalente, duplicar las alturas de cobertura mínima• Las alturas de cobertura son calculadas según metodología de diseño de la AISI
CORRUGA
LUZ
~~ii
I ~ • ILUZ EN BASE
VIGA DE EMPUJESon elementos de concreto armado que se vacian a unaaltura predeterminada a ambos lados y a todo lo largo delas estructuras Super Span. Se unen a la estructura pormedio de conectores y refuerzos de acero.
VARIA VARILLALONGITUDINAL
• EL REFUERZONECESARIOVARIADE ACUERDO ALMODELO DEESTRUCTURAMP152S
• I
PLANCHASLATERALE!ESL--- __ 'Io:\.
CANAL DE ARRANQUELos arcos Super Span se arman sobre muros de arranquede concreto que se unen a las estructuras por medio decanales de arranque en forma de "J".
CANAL DEARRANQUE
PLANCHADE ACERO
ESPECIFICACIONES TÉCNICAS:Las estructuras Multiplate y Super Span cumplen lasnormas internacionales AASHTO M-167 ó ASTM A-761.Son galvanizadas en caliente con un recubrimiento de Znde 610 gr/m2 de acuerdo a ASTM A-123.
••
MODELO LUZ LUZ EN FLECHA AREA PERIMETRO RADIO DEMAXIMA BASE m m2 N TAPA
m m m.
23SA5-3 6.11 5.96 2.77 14.12 39 3.9923SA6-6 6.31 5.74 3.68 19.85 47 3.9925SA5-6 6.56 6.04 3.55 19.93 47 4.3426SA5-6 6.78 6.28 3.59 20.85 48 4.5225SA7-8 6.96 6.05 4.42 26.40 55 4.34
26SA6-8 6.98 6.11 4.26 25.54 54 4.5227SA5-6 7.01 6.52 3.64 21.77 49 4.6928SA5-6 7.23 6.77 3.68 22.71 50 4.8627SA7-8 7.41 6.57 4.52 28.70 57 4.6929SA5-8 7.46 6.67 4.18 26.78 55 5.04
30SA5-7 7.68 7.10 4.00 26.27 54 5.2129SA7-8 7.86 7.07 4.61 31.03 59 5.0431SA5-7 7.91 7.34 4.04 27.31 55 5.3930SA7-8 8.08 7.32 4.65 32.22 60 5.2131SA7-8 8.31 7.57 4.70 33.41 61 5.39
33SA5-7 8.36 7.82 4.13 29.41 57 5.7434SA5-8 8.58 7.91 .4.40 32.31 60 5.9133SAB-8 8.96 8.26 5.00 38.24 65 5.7434SA8-10 9.18 8.15 5.49 43.27 70 5.9136SA6-8 9.23 8.59 4.70 37.04 64 6.26
37SA6-8 9.45 8.84 4.74 38.26 65 6.4436SA8-10 9.63 8.65 5.58 46.11 72 6.2637SA7-10 9.65 8.70 5.41 44.85 71 6.4438SA6-10 9.68 8.75 5.24 43.56 70 6.6137SA8-12 9.85 8.50 6.07 51.40 77 6.44
39SA6-10 9.90 9.00 5.29 44.92 71 6.7938SA8-12 10.08 8.76 6.12 52.98 78 6.6139SA8-12 10.30 9.02 6.16 54.57 79 6.7941SA6-10 10.35 9.49 5.37 47.67 73 7.1341SA7-12 10.55 9.33 6.04 54.79 79 7.13
42SA6-10 10.58 9.74 5.42 49.07 74 7.3141SA8-13 10.75 9.32 6.47 59.85 83 7.1342SA7-12 10.78 9.58 6.08 56.36 80 7.3142SA8-13 10.98 9.58 6.52 61.54 84 7.3141SA11-13 11.35 9.92 7.11 69.28 89 7.13
42SA11-13 11.57 10.18 7.16 71.11 90 7.31
ESPECIFICACIONES TÉCNICAS:Las estructuras Multiplate y Super Span cumplen las normas internacionalesAASHTO M-167 Ó ASTM A-761. Son galvanizadas en caliente con unrecubrimiento de Zn de 610 gr/m2 de acuerdo a ASTM A-123.
CORRUGA
LUZ
-e::J:(,)W....1LL
~ 'ReVIGA DE ""'-EMPUJE
~RI
LUZ EN BASE
VIGA DE EMPUJESon elementos de concreto armado que se vacian a unaaltura predeterminada a ambos lados y a todo lo largo delas estructuras Super Span. Se unen a la estructura pormedio de conectores y refuerzos de acero.
VARIA VARILLALONGITUDINAL
• EL REFUERZO
NECESARIOVARIADE ACUERDO ALMODELO DEESTRUCTURAMP152S
CANAL DE ARRANQUELos arcos Super Span se arman sobre muros de arranquede concreto que se unen a las estructuras por medio decanales de arranque en forma de "J".
CANAL DE
ARRANQUE
...CIMENTACION DE CONCRETO PARA ESTRUCTURA ARCO
NOTAS:
• Las dimensiones (diámetro, luz, flecha, área) son tomadas a la crestainterna de la corrugación
• Son disponibles bajo pedido tamaños mayores e intermedios• Para determinar la periferia total en metros multiplicar el valor N por
0.2438• Las longitudes de las estructuras son valores múltiplos de 6 y 8 pies.• La altura de la cobertura máxima no depende generalmente de las
condiciones de carga viva.• El diseño estructural deberá tomar en cuenta las cargas vivas cuando:
- Carreteras: altura de cobertura menor de 2.5 m- Vías férreas: altura de cobertura menor de 9.0 m
• Para cargas vivas E-80 o equivalente, duplicar las alturas de coberturamínima
• Las alturas de cobertura son calculadas según metodología de diseño delaAISI