ABS Flashing Base Nº 2000 21.0” 21.0” WARNING TO USER: You are required to read and use Super Anchor Safety (SAS) Instruction Specification manuals for this equipment. Improper use can result in serious injury or death. Inspect equipment before use! ABS Flashing Base Riser Height CRA 12=12” CRA 18=18” 16”x16”x3/8” Base Plate Fig.1 Attach plywood backer w/2” length Nº14 deck screws at perimeter. Raised Channel Center fasteners over raised channels 36”x36” or panel width for second panel 3/4”x24”x24” Plywood Backer CRA Commercial Roof Anchor Instruction/Specification Manual 2011.1 rev. CRA-12 Nº 1032 / CRA-18 Nº 1033 PTT and Custom Fabrication Models. Strength Rating: 5,400lb(22.6kN) Materials Specification: A-36 Steel or equivalent. Coating: Galvanized per ASTM 123. Riser: 3”d.x1/4”pipe fitted with a 5/8”d. Loop or Pass Through Top (PTT). Base Plate: 3/8”x16”x16”. Fastener Holes: Screws: 40- 3/8”. Bolts: 8-9/16”. 3/8” drain holes in riser and base. Serial Nº: Stamped or riveted tag. Flashings: Optional ABS Storm Cap and Flashing Base. See Figs.8-9. Includes fastener pack Nº 2022: 40ea.Nº 14x2.5” hex head screws for wood or metal. Use only SAS factory supplied fasteners. Custom Fabrication/Engineering/Field Welding models are available upon request. Specification of Use: Fall Arrest: 1 person. Work Positioning: 4 persons. Maximum body wt. each person of 310lb(140kg). PPE Energy absorbers required for each worker. Horizontal Line: See PTT section page 2. Non-specified use: Do Not Use for scaffolding, window washing or hoisting equipment. PPE Compatibility: Recommend to use SAS safety equipment for “Ensured” compatibility. Structural Engineering: CRA attachment point must be capable of supporting 5,000lb(22kN) or 2 times the intended fall protection load when industrial safety standards permit. All substrates and metal decks must be attached to supporting structure per current building code requirements. Attachments not specified in this manual: Contact SAS for custom or engineered solutions. Plywood/OSB Sheathing Installation: Install anchors onto 3/4” plywood with fastener pack Nº 2022, (40 screws). For plywood less than 3/4” or OSB, a 3/4” backer is required as shown at Fig.2 or 2-B. Visually inspect fastener penetration is a minimum of 3/4”. Do not install onto plywood that has water damage, cracks, cuts, or delamination. Metal Decking 20 Gauge Minimum: Use 36 screws from fastener pack Nº 2022 to penetrate the raised channel section as shown at Figs.3,4 18 gauge or less: Install metal backer panel shown at Fig.5 using same width and 36” length. Or 1/2”x48”x48” plywood base over the metal decking. Insulation Board: Screw fasteners must not exceed 6” in length. For thicknesses greater than 6”, bolts are required or an engineered fastener system. Steel /Wood Beams/Insulation Board / Bolt Attached: Minimum of 4 each grade 5 x 1/2”d. “All Thread” or grade 8 bolts/ nuts as shown at Fig.7. Bolts must extend aprx.1/2” through the nut on the underside. SAS factory supplied backer plates and bolts are required for steel/wood beams. Concrete Minimum Strength 2,000 p.s.i. x 4” thickness: 8 ea. 1/2” x 6,000lb(27kN) tensile strength bolts engineered for concrete embedment and installed per bolt mfg. specifications. See Fig.6. For concrete less than 4” thick, use a 16x16x3/8” steel backer plate supplied by SAS or an engineered specification. ©SCN 12/2011 Pg.1 Loop Top 2.5” Warning Label Serial Nº Riser Base Plate 9/16” Bolt Holes 3/8” Fastener Holes Fig.2 40- Nº14 x 2.5” SAS Hex Head screws. Plywood Backer 3/4”x24”W x48”L Less than 3/4” Fig.2-B Fig.3 Fig.4 Fig.6 Fig.8 Fig.7 Fig.9 Fig.5 Top Chord Spacing Less than 24” Top Chord Plywood Backer Plywood Backer Deck Screws Shown in Red Installed over 20 Gauge Metal decking 36- Nº14 x 2.5” Hex head screws Metal Decking less than 20 gauge Second panel metal decking required. over top or underneath. shown in Red Fasten second panel at perimeter. Shown in Red Concrete Substrate Min. 4 each 1/2”d. Grade 5 “All Thread” or Grade 8 bolts/nuts Insulation Board 2.5” height Storm Cap Nº 2007F Cap Leash Nº 2008F (sst hose clamp not supplied) Embedment Bolts 1/2” x 6,000lb(27kN) tensile strength Aprox. 1/2” thread margin 4” Min. Min. concrete strength 2000 p.s.i. 1/2” margin below concrete Flashing Cross Section Nº2004 2-1/2lb Lead Flashing 16”x16” base, 3-1/8”i.d,14”ht. (Shown in Blue)

Upload: tranngoc

Post on 29-Jun-2018

218 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Super Anchor Safety (SAS) CRA Commercial Roof Anchor ...superanchor.com/images/productPages/craAnchor/PDFs/CRA_Manual... · Safety (SAS) Instruction Specification manuals for this

ABS Flashing Base

Nº 2000

21.0” 21.0”

WARNING TO USER:You are required to read and use Super Anchor Safety (SAS) Instruction Specification manuals for this equipment. Improper use can result in serious injury or death. Inspect equipment before use!

ABS Flashing Base

Riser Height CRA 12=12” CRA 18=18”

16”x16”x3/8” Base Plate

Fig.1

Attach plywoodbacker w/2” length Nº14 deck screws

at perimeter.

Raised Channel

Center fasteners over raised channels

36”x36” or panel width for second panel

3/4”x24”x24” Plywood Backer

CRA Commercial Roof AnchorInstruction/Specification Manual 2011.1 rev.

CRA-12 Nº 1032 / CRA-18 Nº 1033PTT and Custom Fabrication Models. Strength Rating: 5,400lb(22.6kN)Materials Specification:A-36 Steel or equivalent. Coating: Galvanized per ASTM 123. Riser: 3”d.x1/4”pipe fitted with a 5/8”d. Loop or Pass Through Top (PTT). Base Plate: 3/8”x16”x16”. Fastener Holes: Screws: 40- 3/8”. Bolts: 8-9/16”. 3/8” drain holes in riser and base. Serial Nº: Stamped or riveted tag. Flashings: Optional ABS Storm Cap and Flashing Base. See Figs.8-9. Includes fastener pack Nº 2022: 40ea.Nº 14x2.5” hex head screws for wood or metal. Use only SAS factory supplied fasteners. Custom Fabrication/Engineering/Field Welding models are available upon request.

Specification of Use: Fall Arrest: 1 person. Work Positioning: 4 persons. Maximum body wt. each person of 310lb(140kg). PPE Energy absorbers required for each worker. Horizontal Line: See PTT section page 2. Non-specified use: Do Not Use for scaffolding, window washing or hoisting equipment.PPE Compatibility: Recommend to use SAS safety equipment for “Ensured” compatibility.

Structural Engineering:CRA attachment point must be capable of supporting 5,000lb(22kN) or 2 times the intended fallprotection load when industrial safety standards permit. All substrates and metal decks must beattached to supporting structure per current building code requirements. Attachments not specified in this manual: Contact SAS for custom or engineered solutions.

Plywood/OSB Sheathing Installation:Install anchors onto 3/4” plywood with fastener pack Nº 2022, (40 screws). For plywood less than 3/4” or OSB, a 3/4” backer is required as shown at Fig.2 or 2-B. Visually inspect fastener penetration is a minimum of 3/4”. Do not install onto plywood that has water damage, cracks, cuts, or delamination.

Metal Decking 20 Gauge Minimum:Use 36 screws from fastener pack Nº 2022 to penetrate the raised channel section as shown at Figs.3,418 gauge or less: Install metal backer panel shown at Fig.5 using same width and 36” length. Or 1/2”x48”x48” plywood base over the metal decking. Insulation Board: Screw fasteners must not exceed 6” in length. For thicknesses greater than 6”, bolts are required or an engineered fastener system.

Steel /Wood Beams/Insulation Board / Bolt Attached:Minimum of 4 each grade 5 x 1/2”d. “All Thread” or grade 8 bolts/ nuts as shown at Fig.7. Bolts must extend aprx.1/2” through the nut on the underside. SAS factory supplied backer plates and bolts are required for steel/wood beams.

Concrete Minimum Strength 2,000 p.s.i. x 4” thickness:8 ea. 1/2” x 6,000lb(27kN) tensile strength bolts engineered for concrete embedment and installedper bolt mfg. specifications. See Fig.6. For concrete less than 4” thick, use a 16x16x3/8” steel backer plate supplied by SAS or an engineered specification.

©SCN 12/2011 Pg.1

Loop Top 2.5”Warning Label Serial Nº Riser Base Plate

9/16” Bolt Holes

3/8” Fastener Holes

Fig.240- Nº14 x 2.5”SAS Hex Head

screws.

Plywood Backer 3/4”x24”W x48”L

Less than3/4”

Fig.2-B

Fig.3

Fig.4Fig.6

Fig.8

Fig.7

Fig.9Fig.5

Top Chord Spacing Less than 24”

Top Chord

Plywood Backer Plywood Backer

Deck Screws Shown in Red

Installed over

20 Gauge Metal decking

36- Nº14 x 2.5”Hex head screws

Metal Decking less than 20 gauge

Second panelmetal decking required. over top or underneath.

shown in Red

Fasten second panel at perimeter.

Shown in Red

Concrete SubstrateMin. 4 each 1/2”d.

Grade 5 “All Thread” or Grade 8 bolts/nuts

Insulation Board

2.5” heightStorm Cap Nº 2007F Cap Leash Nº 2008F

(sst hose clamp not supplied)

Embedment Bolts1/2” x 6,000lb(27kN)

tensile strength

Aprox. 1/2” thread margin

4” Min.

Min. concrete strength 2000 p.s.i. 1/2” margin below concrete

Flashing Cross Section

Nº2004 2-1/2lb Lead Flashing

16”x16” base, 3-1/8”i.d,14”ht. (Shown in Blue)

Page 2: Super Anchor Safety (SAS) CRA Commercial Roof Anchor ...superanchor.com/images/productPages/craAnchor/PDFs/CRA_Manual... · Safety (SAS) Instruction Specification manuals for this

Pg.2

Metal Energy Absorber: Nº1059 is equipped with Tension and Force indicators. Absorber Coupler Nº1053, Fig.11-B, is requiredto link a turnbuckle to a Metal Energy Absorber. PTT/PPE Adaptor Nº1054 shown at Fig.19, converts a PTT top fixture into a loop top forattachment of fall protection equipment. O-Ring Nº5010 Require one per worker.Insert onto cable before forming end loops.

Metal Energy Absorber: Consult Metal Energy absorber instructions before use. Attach end “A” to CRA Loop top with SAS M12x60mm sst. bolt and lock nut, and B-end of absorber to cable loop end, Fig.12. With Turnbuckle: Attach Turnbuckle A-end to CRA Loop top. Use Absorber Coupler Nº1053, Fig.11-B, to attach B-end of absorber to turnbuckle B-end and A-end to a cable loop. Tension Indicator: Absorber B-end green arrow indicates the correct amount of tension when the interior indicator is NOT visible. Force Indicator: A-end red arrow interior indicator will be visible when the HLS has been subjected to a force load. If deployed DO NOT USE HLS and determine cause.

O-Ring PTT Top Fixture Riser Base Plate 3/8 Galvanized Cable 7x19 Nº1055 O-Ring

Lifeline w/Snap-hook or

Carabinerconnected to O-Ring

21.5

29.5 8.0”

2.0”

2.0”

Min.ThreadBuffer

4.0”

4.0”

4.0”

2.0”

PPEShock Absorberw/Snap-hook.

PTT AnchorPass Through Top

12 Strand Lifeline

Fig.16 Fig.17 Fig.18

Dead Side Cable ClampNº1056

CRACorner

Cable Loop

O-RingNº5010

Cable Loop

PTT Intermediate

CRAEnd

Recommended Anchor Spacing

Maximum 20ft(6m) Maximum 20ft(6m) Maximum 120ft(36m)

Anchor Spacing:Recommended spacing between anchors is 20ft(6m) as shown at Figs.16,17,18. Maximum horizontal line lengthis 120ft(36m). Set anchors 6-10ft(2-3m) from leading edges. Consult SAS plan service for anchor locations.PTT Anchors / Horizontal Line System ( HLS):The Pass Through Top (PTT) is designed for a Horizontal Line System (HLS). Shown at Fig.10,O-Ring Nº5010, is installed onto a 3/8” d. steel cable Nº1055. PPE is connected to the O-Ring and passes through the PTT by rotating the ring. HLS components have a minimum breaking strength of 5,000lb(22.6kN.) HLS Factory Engineered System: Fall Arrest = 1 person. Work Positioning 4 persons. Additional workers may be added when specified by an engineer or qualified person in a written plan. Specification for Factory Engineered System:

Warning: Only SAS supplied HLS components qualify as a “Factory Engineered System”.Components supplied by others require engineering by a qualified or competent person.

Corners/Ends: Use only loop top models Nº1032-1033 shown at Figs.16,18.Intermediate Anchors: Nº1032-P/1033-P shown at Figs.10,17. Cable: Nº1055 galvanized 3/8”-7x19 steel cable.End Loops: Use 3 SAS Nº1056 Crosby clampsor equal for each end loop as shown at Fig.12.Turnbuckles: Nº1058-3/4” galvanized Jaw-Jaw type.Lengths over 60ft,(18m) use turnbuckles on both ends.

Cable Attachment / Cable Length Calculation:Cable length is the distance between two ends or corners plus 18” for each loop as shown at Figs.12&16. Do not add 18” when turnbuckles or energy absorbers are used. See Figs.18,11-A. Connect Turnbuckles to anchors or loop ends with factory supplied shackle and cotter pin. Some Turnbuckles have a lock nut. Cotter pins are required to prevent accidental disengagement. An equal size grade 8 bolt and lock nut may be substituted. Cable end loops: are required to be formed as shown at Fig.12 for all terminations or connections to turnbuckles and energy absorbers. Us a torque wrench to evenly tighten all clamp nuts to 45lb. Cable Tension: Tighten turnbuckles leaving a minimum of 2” of slack in the line. WARNING ! DO NOT over tighten cable to prevent damage to the anchor fasteners and supporting structure. Non-Specified Use: Do not use PTT anchors for corners or ends. WARNING ! DO NOT attach fall protection equipment to a PTT anchor top, cable loop end, turnbuckle or around the riser as it may result in unintentional disengagement when subjected to a static load or in service loading (free fall) .

Inspection / Maintenance:Inspect all components of the HLS prior to each use.Do not use if any of the following conditions are present:•Cable: Broken, cut, frayed, or creased strands.•Clamps: Loose or Missing clamps/ nuts.•Turnbuckles: Loose, missing cotter pins, Broken or

bent. •O-Ring: Missing, bent, out of round. Replace.•Energy Absorber: Attachment bolt/nut missing, or

loose.Tension indicator visible. Cable is too tight. Loosen turnbuckle. Fall Indicator visible: Do Not Use if HLS has been subjected to a force load or used by wire walkers.

•CRA/PTT: Loop/PTT top or riser is bent. Anchor is loose.

Free Fall / In Service Loading:HLS components subjected to a free fall or other forcemust be removed and replaced before further use.Anchors: Are not required to be replaced provided they have been inspected by a “qualified person” or engineer andthere is no evidence of damage to the anchor, the fastenersor the supporting structure.

Fits over PTT top andsecures with Detent pin

Rated for one worker only

21.5

29.5 8.0”

2.0”

2.0”

Min.ThreadBuffer

4.0”

4.0”

4.0”

2.0”

Fig.12

Fig.19

Fig.11-A

Fig.11-B

Fig.15

Fig.13 Fig.14Metal Absorber

Nº1059

Bolt

Bolt

3.5”

Coupler Nº1053

ShacklePin/Bolt

End Loop

Cable ClampsNº1056

Turnbuckle Nº1058

Lock Nut

Cotter Pin

Shackle Pin

Maximum Extension

Min. ThreadBuffer

Position clamp saddleonto live side of cableSaddle

PTT-PPEAdaptor Nº1054

w/Detent Pin Nº 2016

A-End

A-End

B-End

B-End

12.0”