super alternator
TRANSCRIPT
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
SuperturbineTM
Welcome to PMALT.com home of the SuperturbineTM
SuperAlternatorTM
the SuperturbineTMSuperAlternatorTM SUPERTURBINE PMA Alternator Wind Turbine Generator 2kW+High Voltage, Low Wind Speed, Low Cogging : Full Power of 2 kW at 600 RPM, depending on current draw & voltage of load
SUPERALTERNATOR! (2 kW HighVoltage PermanentMagnet Alternator) The MOTHER of all PMA's (Permanent Magnet Alternators)Shown next to a Delco 10Si alternator for comparison 35 mm diameter driveshaft, 5.5" long projection forward from caseAttachment bolts: 1/2" diameterInside Distance Between mounting ears of case: 4.130"Output: 3Phase Alternators are named for their nominal voltage at cutin speed of 8 mph for a 12foot diameter rotor
Output Voltage vs RPM for the "240Volt" model: 0.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
This Alternator is the perfect size for an 8foot to 12foot diameter Wind Turbine rotor. The voltage range is perfect for use with a WindyBOY Gridtie inverter, also available through this seller. The WindyBOY requires overvoltage protection, (WindyGIRL) also available through this seller. You can turn your meter backwards using your own homebuilt wind turbine, based on this SUPERALTERNATOR! (See below for description of WindyBOY inverter and WindyGIRL overvoltage protection, also available from this seller.)
Three output wires deliver 3phase electricity. with both voltage and frequency proportional to RPM.
This SUPERALTERNATOR is WAY MORE POWERFUL than the PMA's you are used to seeing on EBay. The Superturbine(R) Alternator weighs a whopping 32 LBS!!!compare to PMA's based on the Delco 10si series, weighing in at a mere 10 lbs.
This SuperTurbine(R) SuperAlternator is good for sustained output of 2000 watts, on a tower with wind blowing thru. For groundbased use, consider a cooling fan. This alternator is capable of 10 kW output in short bursts.But the factor limiting sustained output of any alternator or motor is temperature, which can quickly start to climb, ending in a burntout stator.
We will not be responsible for a burntout stator, since this is a SUPERBEEFY alternator, wellproven for hours of sustained full output,in sustained high winds, over years of use, in all climates,.Since we cannot control what you do with it, you gotta see if it is getting hot and take steps to prevent overheating, cause that is just the name of the game in wind energy. Same thing goes for using a gas engine to turn the gen., etc. You have to engineer your system so the components match and work together properly, loading the alternator appropriately, keeping temps from rising to damaging levels, using a cooling fan or heat sink etc., as required in your unique situation. One factor in your favor with a wind turbine: The harder the generator is asked to work, the more cooling wind flows through the alternator!
Perfect for VERTICALAXIS Machines, which often turn slower and have trouble reaching useful voltages at low RPM. We can make you an alternator wound for ANY voltage range, all you gotta do is ask.
Made in USA. Highest quality materials and components, nothing to wear out. If properly loaded, this machine should last forever. Extraheavyduty sealed bearings can be replaced, but we have never worn out a bearing yet, in years of use, in the harshest arctic and desert environments!90 Day warranty parts & labor for defects in materials or workmanship.
This sale is FOR THE ALTERNATOR (PMA) ONLY!You will need a rectifier to turn the 3phase output to DC, if you want DC output. Call and we can set you up with a rectifier: 7149925594
Weight: 35 LBS.Shipping Free in the U.S. & Canada!!!We ship immediately!More info: 7149925594 Good Luck and Thanks for your business!
The SELSAM SuperAlternatorTM, using High Temp Neodymium SuperMagnets, is the most powerful PMA on the market. The SELSAM SuperAlternatorTM outweighs, and outpowers 3 Delcotype alternators.
You can expect the above power curve using a 12foot diameter rotor that has furling or other overspeed protection
SuperturbineTM Your new SELSAM SuperAlternatorTM is MADE IN USA
Shipping free in the U.S., Canada. Please call first for overseas orders.
Order by mail: Send check or money orders payable to Selsam Innovations2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
WindyGIRLTM and WindyBoyTM The perfect combination!
400 Volt version for WindyBoy 1800 U 500Volt version for WindyBOY 3000US 600 Volt version for WindyBoy 2500 U , 5000US, 6000US, 7000US 60 Volt version for WindyBoy 1100 LV
WindyGIRLTM is connected between your wind turbine and your WindyBoyTM inverter from SMAAmerica.
3Phase in, DC out, 600 Volt WindyGIRLTM model WG6003P protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
DC in, DC out, 600 Volt WindyGIRLTM model WG600DC protects the SMA WindyBoy 2500 U Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
WindyGIRLTM Connects, Rectifies, Protects, and Allows manual control of electronic turbine brake
NOTE:Yellow and Green wires for manual braking switch normally left off, unless requested.
SELSAM WindyGIRLTM Patent Pending
VOLTAGE LIMITING RECTIFIER (VLR)A SuperturbineTM PRODUCT
Purple: 3phase Input; Red (+), Black (): DC Output 60 V, 400 V, 500 V, or 600 V max.
Yellow, Green: Brake SwitchConnect yellow and green to brake turbine
Automatic Braking Applied at (just below) 60, 400, 500, or 600 Volts
WindyGIRLTM 60 Volt DC Voltage Limiting Brake (VLB)
WindyGIRLTM 60 Volt DC (VLB) protects the SMA WindyBoy 1100 Low Voltage Grid Inverter note: We are no longer including the yellow and green wires for manual triggering. Please use a proper disconnect/brake switch as per code.
SELSAM SuperturbineTM products are protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT) Patents Pending.
©2007 Doug Selsam SuperturbineTM is a registered U.S. Trademark.
Selsam Innovations / Superturbine Inc. / USWINDLABS.com 2600 Porter Ave. Unit BFullerton, CA 92833
7149925594http://www.selsam.com
http://www.WindyGIRL.biz [email protected]
SuperturbineTM
Your new SELSAM WindyGIRLTM Interface MADE IN USA
Ordering:WindyGirlTM Interface I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
SELSAM WindyGIRLTM connects your SELSAM SuperturbineTM (OR OTHER WIND TURBINE) to your Windy BoyTM (or other) GridTie Inverter.
WindyGIRLTM protects the Windy BoyTM from overvoltage (brakes turbine to a stop at just below 60 volts, 400 volts, 500 volts, or 600 volts, depending on model, then allows restart)
If requested: WindyGIRLTM allows manual turbine shutdown (electronically stops turbine connect to any switch) note: We are no longer including the yellow and green wires for manual triggering unless requested. We want to keep things simple. Please use a proper disconnect/brake switch.
WindyGIRLTM works with any turbine compatible with the Windy BoyTM (DC voltage operating range 139400 volts) 500 volt version for Windy BoyTM 3000US, 600 volt version for Windy BoyTM 2500U, 5000US, 6000US, 7000US easy to use email or call anytime We make Any WindyGIRL, Any Voltage, Any Power Level, with any extra features such as manual triggering, just for you!
Order your WindyGIRLTM here RIGHT NOW from FactoryDirect ! in California 7149925594
SELSAM WindyGIRLTM will fit into a variety of enclosures for both indoor and outdoor placement
You CAN connect to the power grid, reduce peak power use, turn your meter backwards, and lower your electric bill!
ORDER ONLINE: WindyBOYTM Inverter AND WindyGirlTM Voltage Protection
I would like to order:
<= CLICK BUTTON TO COMPLETE ORDER
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501, other U.S. and International (PCT)
Patents Pending. SuperturbineTM is a registered U.S. Trademark. USWINDLABS.com
CUSTOMDESIGN AND MANUFACTURE OF WindyGIRLTM UNITS FOR YOUR SPECIAL USE:
WindyGIRL Voltage Limiting Rectifier protects GRIDTIE INVERTERS from overvoltage, while rectifying 3phase AC generator output, to the DC required by the inverter input. We design and manufacture WindyGIRL in any power level or voltage, for any turbine, any inverter. Custom orders are normal for us. Call 7149925594 to order WIndyGIRL or visit http://www.WindyGIRL.biz
Order by mail: Send check or money orders payable to Factory Direct 2600 Porter Ave. Unit B, Fullerton, CA 92833
Order by phone: Call us anytime at 7149925594
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website!
http://www.DualRotor.comVisit the incredible and futuristic SELSAM Superturbine website! http://www.SELSAM.com
Prices are subject to change, so act in a timely manner if you really wish to take advantage of these great deals. Thank you.
The SELSAM ST1.2 American Twin SuperturbineTM is protected by U.S. Patents 6616402, 6692230, 7008172, 7063501 other U.S. and
International patents, and patents pending. SuperturbineTM is a registered U.S. Trademark
Visit the SELSAM ST 1.2 American Twin DualRotor 1 kW SuperturbineTM website! http://www.DualRotor.com
Visit the incredible SELSAM Superturbine website! http://www.SELSAM.com
Retail Price: $1,299.99
Factory Special: $899.99 !!!
PURCHASE: ONE (1)
SuperAlternatorTM 240 Volt Model 8 Amps cont. $899.990.8 Volts per RPM12 Volts @ 16 RPM40 Volts @ 50 RPM48 Volts @ 60 RPM80 Volts @ 100 RPM200 Volts @ 250 RPM400 Volts @ 500 RPM500 Volts @ 625 RPM600 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 160 Volt Model 12 Amps cont. $899.990.533 Volts per RPM12 Volts @ 24 RPM33 Volts @ 50 RPM54 Volts @ 100 RPM133 Volts @ 250 RPM266 Volts @ 500 RPM333 Volts @ 625 RPM400 Volts @ 750 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 96 Volt Model 18 Amps cont. $899.990.32 Volts per RPM16 Volts @ 50 RPM24 Volts @ 75 RPM32 Volts @ 100 RPM48 Volts @ 150 RPM80 Volts @ 250 RPM96 Volts @ 300 RPM160 Volts @ 500 RPM200 Volts @ 625 RPM250 Volts @ 750 RPM333 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 48 Volt Model 36 Amps cont. $899.990.16 Volts per RPM8 Volts @ 50 RPM12 Volts @ 75 RPM16 Volts @ 100 RPM24 Volts @ 150 RPM40 Volts @ 250 RPM48 Volts @ 300 RPM80 Volts @ 500 RPM100 Volts @ 625 RPM125 Volts @ 750 RPM166 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 36 Volt Model 48 Amps cont. $899.990.12 Volts per RPM12 Volts @ 100 RPM24 Volts@ 200 RPM36 Volts @ 300 RPM48 Volts @ 400 RPM72 Volts @ 600 RPM 120 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 24 Volt Model 72 Amps cont. $899.990.08 Volts per RPM12 Volts @ 150 RPM24 Volts @ 300 RPM36 Volts @ 450 RPM48 Volts @ 600 RPM72 Volts @ 900 RPM80 Volts @ 1000 RPM
" Click Here for Secure Payment Form"
PURCHASE: ONE (1)
SuperAlternatorTM 12 Volt Model 140 Amps cont. $899.990.04 Volts per RPM12 Volts @ 300 RPM24 Volts @ 600 RPM36 Volts @ 900 RPM48 Volts @ 1200 RPM
" Click Here for Secure Payment Form"
Welcome to PMALT.com SuperturbineTM
SuperAlternatorTM WindyGIRLTM
Voltage Limiting Rectifier (VLR)and
DC Voltage Limiting Brake (VLB)
WindyGIRLTM Protects Your WindyBoyTM inverter from OVERVOLTAGE Order from selection below or call for a customdesigned unit for your turbine/inverter.
We gladly custombuild WindyGIRLTM units just for you. 7149925594
WindyGIRLTM protects the SMA Windy Boy GridTie Inverter. This WindyGIRL brakes the turbine to a stop or crawl before the trigger voltage is reached.
Once stopped, the turbine is allowed to restart. This assumes your turbine can be braked electrically. If not, you may damage your turbine but your inverter will be protected.
nmlkji ONE (1) SELSAM WindyGIRLTM
400 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 1800 U Inverter with 400 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $139.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 2500 U Inverter with 600 Volt autobrake, manual brake switch leads,onboard 3phase rectifier $149.99 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Rectifier (VLR) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, 3 purple input wires, red & black output wires,onboard 3phase rectifier $155.55 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 500 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 3000 US Inverter with 500 Volt autobrake, DCin / DCout red & black input wires, red & black output wires, $155.56 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 400 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1800U Inverter with 400 Volt autobrake, manual brake switch leads,DC Input and DC Output $139.98 plus $10 S&H
nmlkj ONE (1) SELSAM WindyGIRLTM 600 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 2500U Inverter with 600 Volt autobrake, manual brake switch leads,DC Input and DC Output $149.98 plus $10 S&H
nmlkj
ONE (1) SELSAM WindyGIRLTM 60 Volt Voltage Limiting Brake (VLB) for the WindyBoyTM 1100 LV Inverter with 60 Volt autobrake, manual brake switch leads,DC Input and DC Output $159.98 plus $10 S&H
" Click Here for Secure Payment Form"
nmlkji ONE (1) SELSAM WindyGIRLTM
500 Volt Voltage Limiting Rectifier (VLR)
and
ONE (1) SMA WindyBOY 3000US Inverter $2499 plus $199 for Processing, Packing, Shipping= $2698 total Package including delivery to the U.S.
" Click Here for Secure Payment Form"
Call for larger inverters, custom WindyGIRL circuits
IMPORTANT NOTE: WindyGIRL is intended for turbines that can be electrically braked from full power to a stop. A long distance of wire from the turbine may affect
braking performance of any attempt to stop the turbine electrically. A very long run of thin wire between a brake switch and the turbine may in some cases allow the
turbine to keep running even when the leads are "shorted out" (brake is on) since the length of wire itself has enough resistance to present an operating voltage to the
turbine. Consider this when placing your WindyGIRL since it also acts to brake the turbine electrically. Therefore consider limiting the length of your wire run, using very
thick wire, and/or placing the WindyGIRL reasonably close to the turbine for best braking results. Choose an inverter that is big enough to handle your turbine. We want
to hear your experience with WindyGIRL so we can continue to make it the best it can be.
Order your WindyGIRLTM now! Click below or Call SELSAM SuperturbineTM at 7149925594
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor