sulfur transport pipelines - ac controls thermal... · characteristics of sulfur line through...
TRANSCRIPT
Sulfur Transport PipelinesSafe, Reliable and Cost-Effective Heat Management System
Safe Sulfur TransportWith the increasing use of heavy crude, safe sulfur transportation is becoming
increasingly important for the refining industry. Sulfur transport via heated pipelines is a viable alternative to transporting liquid sulfur by trucks over public roadways.
This application has unique requirements due to the limited temperature range for liquid sulfur, pipe expansion and overheating concerns during
re-melting of sulfur in the pipeline.
A Global Solutions Company Tyco Thermal Controls is a world leader in providing
heat management solutions for the industrial, commercial and residential markets. With operations in 56 countries,
Tyco Thermal Controls has worldwide capabilities to support your project needs anywhere, anytime.
Unique Heat Management SolutionTyco Thermal Controls has successfully integrated multiple state-of-the-art technologies in a heat
management system to offer safe, reliable and cost effective sulfur transport. Our Heat Management System (HMS) for sulfur transfer pipeline includes Tracer® Skin-Effect Heat Tracing System, Customized Insulation and
Power distribution systems, Finite Element Analysis and Fiber-Optic Distributed Temperature Sensing. This unique heat management system is combined with proven experience in engineering, procurement, construction and commissioning
of sulfur pipelines.
Engineering & Design• Skin-Effect Heating Tracing Technology• 3D Finite Element Analysis• Transient Analysis• Fiber-Optic Distributed Temperature Sensing• Detailed System Optimization
Procurement & Fabrication• Prefabricated and Pre-insulated Piping System• Customized Power Distribution• Multi-Power Heat Delivery Mechanism• Control and Monitoring System• Thermal Insulation• Fiber-Optic DTS System
Construction Services• Installation• Materials Management• Project Controls• Commissioning and Start-up• Field Co-ordination• Quality Assurance/Quality Control (QA/QC)• Maintenance/Audits
A Heat Management System (HMS) is an engineered system designed to maintain or protect process piping, equipment, vessels and instrumentation at pre-determined temperatures and within the defined design criteria. Our HMS for sulfur transport pipelines includes: Engineering & Design, Procurement & Fabrication, and Construction Services.
By implementing Tyco Thermal Controls' HMS, customers have realized more reliable, safe and cost effective solutions for sulfur transport pipelines as compared to other technologies. A list of existing customers is available upon request.
Heat Management System
3
Skin-Effect Heating System (STS™)
4
The Tracer® STS system is a versatile engineered heat management system configured to deliver heat for long
pipeline applications. The system can generate significantly higher wattages and is inherently safe.
AC VOLTS(Outside surface to earth)
AC VOLTS(Inside surface to conductor)
Capabilities• Circuit lengths up to 25 km (15 miles) from a
single source
• Maintain temperatures up to 200ºC (392ºF) and exposure temperatures up to 250ºC (482ºF)
• Power outputs up to 150 W/m (45.7 W/ft)
• Inherently safe design — outside of the heat tube or carrier pipe at ground potential
• Efficient heat transfer from heat tube to the pipe
• Can be provided as a pre-fabricated and pre-insulated piping system
Benefits for Sulfur Transport Pipelines• Minimizes power distribution costs, especially
for long sulfur lines
• Results in safe and reliable heat management system
• Reduces risk of hot spots during re-melt or solidification during normal operation
• Reduces on-site total installation costs
Control and monitoring
panel
Transformer
Power box
RTD
Carrier pipe
Heat tube
Termination box
Pull box
Skin-Effect Heating System (STS™)
5
Capabilities• Multi-layer thermal insulation system with
high temperature inner layer, load bearing outer layer, and UV resistant outer jacket
• Engineered pipe supports, guide plates and anchors to carry pipe load to minimize heat loss
• Multi-power heat delivery mechanism with additional power for heat-up/re-melt conditions
• Custom manufactured transformers
Benefits for Sulfur Transport Pipelines• Optimizes heat loss, protects against water
ingress and natural elements, and able to handle large loads
• Minimizes operating costs with capacity to handle heat-up/re-melt power requirements
• Enables flexible operating voltage required for re-melt condition
System
Insulation Power Distribution
Customized
Tyco Thermal Controls has proven expertise in designing customized insulation and power distribution systems. Our systems are optimized to meet the challenging requirement of sulfur transport pipelines.
Capabilities• Simulate the temperature profile of sulfur
across the cross section of the pipe
• Determine the heat-up or cool-down characteristics of sulfur line through transient analysis
• Simulate the temperature profile along the length of pipe
Benefits for Sulfur Transport Pipelines• Ensures that sulfur temperature is not
below the solidification temperature across the cross section of the pipe
• Determines the time available before the sulfur solidifies due to power failure under different ambient conditions
• Analyzes hot spots and voids during re-melt conditions
6
37 hours
32 hours
26 hours
21 hours
3D Finite Element Analysis is an integral part of Tyco Thermal Controls' sulfur transport pipelines heat management system.
5Contact Tyco Thermal Controls Heat Management System Expert today for your sulfur transport needs at [email protected].
Fiber-OpticDistributedTemperature Sensing
7
Capabilities• Temperature profile with 1ºC accuracy and 1 m
resolution along the length of the pipeline
• Capable of sensing temperatures for up to 60 km (37 miles) of pipeline from each station
Benefits for Sulfur Transport Pipelines• Prevents pipe damage during re-melting of
solidified sulfur by precisely locating hotspots or voids along the length of pipe
• Senses temperature for long sulfur transport pipelines with multiple flow paths
• Helps during commissioning by pinpointing the locations of inadequate or absent insulation along the length of pipe
Tyco Thermal Controls has a proven track record of implmenting distributed fiber-optic temperature sensing solution that provides incredible insight into the temperature profile along the entire length of pipe.
180
170
160
150
140
130
120
110
1001410 1420 1430 1440 1450 1460 1470 1480 1490
Tem
pera
ture
(deg
ree
C)
Distance (m)
20ºC
Fiel
d Jo
int
Fiel
d Jo
int
Fiel
d Jo
int
Elbo
w
Elbo
w
Expansion Loop
Fiel
d Jo
int
Fiel
d Jo
int
12m12m 12m
© 2
010
Tyco
The
rmal
Con
trols
LLC
H
5863
1
04/1
0
Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls’ only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal Controls or its distributors be liable for any incidental, indirect, or conse-quential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes—without notification to Buyer—to processing or materials that do not affect compliance with any applicable specification.
Tyco, STS, Tracer, and We manage the heat you need are trademarks of Tyco Thermal Controls and its affiliates.
Worldwide HeadquartersTyco Thermal Controls307 Constitution DriveMenlo Park, CA 94025-1164USA Tel: 800-545-6258 Tel: 650-216-1526 Fax: 800-527-5703Fax: [email protected] www.tycothermal.com
U.S.A.Tyco Thermal Controls 307 Constitution DriveMenlo Park, CA 94025-1164USA Tel: 800-545-6258 Fax: 800-527-5703
CanadaTyco Thermal Controls 250 West St.Trenton, OntarioCanada K8V 5S2Tel: 800-545-6258 Fax: 800-527-5703
Latin AmericaTyco Thermal Controls 7433 Harwin DriveHouston, TX 77036Tel: 713-868-4800 Tel: 713-735-8645Fax: 713-868-2333
Europe, Middle East, Africa Tyco Thermal ControlsRomeinse Straat 143001 LeuvenBelgië / BelgiqueTel: +32 16 213 511Fax: +32 16 213 603
Asia PacificTyco Thermal Controls 20F, Innovation Building, 1009 Yi Shan Rd,Shanghai 200233, P.R.ChinaTel: +86 21 2412 1688Fax: +86 21 5426 2937 / 5426 3167