June 2019:
Successful 12Km tunnel inspection at Duge pumping station
![Page 2: Successful 12Km tunnel inspection at Duge pumping station](https://reader031.vdocuments.us/reader031/viewer/2022012016/615b19b155b47e0e2a417200/html5/thumbnails/2.jpg)
Project Engineer Project Manager Technical Support Manager
Technical Manager Asset Manager General Manager
Diving Supervisor ROV Supervisor ROV Pilots
Background
![Page 3: Successful 12Km tunnel inspection at Duge pumping station](https://reader031.vdocuments.us/reader031/viewer/2022012016/615b19b155b47e0e2a417200/html5/thumbnails/3.jpg)
![Page 4: Successful 12Km tunnel inspection at Duge pumping station](https://reader031.vdocuments.us/reader031/viewer/2022012016/615b19b155b47e0e2a417200/html5/thumbnails/4.jpg)
ROV Pilots
Project Engineer
Project Manager
Technical Support Manager
Technical Manager
Asset Manager
Diving Supervisor
General Manager
Work Class ROV Systems
Resident Remote Controlled Systems
![Page 5: Successful 12Km tunnel inspection at Duge pumping station](https://reader031.vdocuments.us/reader031/viewer/2022012016/615b19b155b47e0e2a417200/html5/thumbnails/5.jpg)
Design Criteria – Development of tunnel Survey ROV
5
Range Dimensions Infrastructure Risk
15 000 m Light weight
Small dimensions
Battery powered Specialisation
![Page 6: Successful 12Km tunnel inspection at Duge pumping station](https://reader031.vdocuments.us/reader031/viewer/2022012016/615b19b155b47e0e2a417200/html5/thumbnails/6.jpg)
![Page 7: Successful 12Km tunnel inspection at Duge pumping station](https://reader031.vdocuments.us/reader031/viewer/2022012016/615b19b155b47e0e2a417200/html5/thumbnails/7.jpg)
7
Product
NOTUS ROV
ROV 700Kg
Controlroom 700Kg
Battery 20Kwh
Fibercable 15Km
![Page 8: Successful 12Km tunnel inspection at Duge pumping station](https://reader031.vdocuments.us/reader031/viewer/2022012016/615b19b155b47e0e2a417200/html5/thumbnails/8.jpg)
SaurdalPurpose: Verification of known rockslide
Conclusion: Rockslide identified 1300m from shafthouse.
Time-consume: 4 h in tunnel- 24 h mob/demob 8
![Page 9: Successful 12Km tunnel inspection at Duge pumping station](https://reader031.vdocuments.us/reader031/viewer/2022012016/615b19b155b47e0e2a417200/html5/thumbnails/9.jpg)
DugePurpose: Inspection of sandtraps and potential rockslide
Conclusion: No major irregularities found
Time-consume 14 h in tunnel- 48 h mob/demob9
![Page 10: Successful 12Km tunnel inspection at Duge pumping station](https://reader031.vdocuments.us/reader031/viewer/2022012016/615b19b155b47e0e2a417200/html5/thumbnails/10.jpg)
360 Degrees Sonar-Live & post porcess
Profiling Sonar
Postion Data
Visual/Video10
Data
![Page 11: Successful 12Km tunnel inspection at Duge pumping station](https://reader031.vdocuments.us/reader031/viewer/2022012016/615b19b155b47e0e2a417200/html5/thumbnails/11.jpg)
11
Open Platform –Technology & Competence conversions from O&G subsea