submittal md-mml 2-28-13 - titus hvac · pdf filesubmittal md-mml 2-28-13 all dimensions are...

4
Submittal Countersunk Screw Holes for #8 SMS (8 from Edge) O’= D’+ 22 19 S D’=Duct Size 29 3 44 D’=Duct Size O’= D’+ 22 19 S 29 3 44 A 3 to 13 D’=Duct Size O’ 19 S 84 3 44 S S MD-MML 2-28-13 S S Supply Model MML-37 S=13mm MML-38 S=19mm MML-39 S=25mm Return Model MMLR-37 S=13mm MMLR-38 S=19mm MMLR-39 S=25mm Border Type 1A With Flange Border Screw Mounting Border Type 1B With Flange Border Duct Mounting Border Type 2A Border Type 2B Both with Flange Border Concealed Mounting † See Page 3 MD-1.0-S Dimensions are in millimeters. (Please see reverse side). Linear Slot Ceiling Diffusers Aluminum Modulinear Models: MML-37 13mm Slot Supply MML-38 19mm Slot Supply MML-39 25mm Slot Supply MMLR-37 13mm Slot Return MMLR-38 19mm Slot Return MMLR-39 25mm Slot Return Type A 0’ 2A 29 D’ + 19 2B 22 D’ + 6

Upload: vonhi

Post on 20-Mar-2018

215 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Submittal MD-MML 2-28-13 - Titus HVAC · PDF fileSubmittal MD-MML 2-28-13 All dimensions are in millimeters. Check if provided 90 Degree (Minimum) Larger than 90 degree. Specify Cut

Submittal

Countersunk Screw Holesfor #8 SMS (8 from Edge)

O’= D’+ 22

19S

D’=Duct Size

293

44

D’=Duct Size

O’= D’+ 22

19S

293

44

A

3 to 13

D’=Duct Size

O’

19S

84

3

44

SS

MD-MML 2-28-13

SS

SupplyModel MML-37 S=13mm

MML-38 S=19mmMML-39 S=25mm

ReturnModel MMLR-37 S=13mm

MMLR-38 S=19mmMMLR-39 S=25mm

Border Type 1AWith• Flange Border• Screw Mounting

Border Type 1BWith• Flange Border• Duct Mounting

Border Type 2ABorder Type 2BBoth with• Flange Border• Concealed Mounting

† See Page 3 MD-1.0-SDimensions are in millimeters.(Please see reverse side).

Linear Slot Ceiling DiffusersAluminum • ModulinearModels: MML-37 • 13mm Slot • Supply

MML-38 • 19mm Slot • SupplyMML-39 • 25mm Slot • SupplyMMLR-37 • 13mm Slot • ReturnMMLR-38 • 19mm Slot • ReturnMMLR-39 • 25mm Slot • Return

Type A 0’2A 29 D’ + 192B 22 D’ + 6

Page 2: Submittal MD-MML 2-28-13 - Titus HVAC · PDF fileSubmittal MD-MML 2-28-13 All dimensions are in millimeters. Check if provided 90 Degree (Minimum) Larger than 90 degree. Specify Cut

Frame & Border Types, Dimensions (Continued)

† See Page 3

O’= D’- 3

D’=Duct Size

19

19S

4884

O’

3SA

D’+ 32D’+ 13

D’=Duct Size

19

84

2714

49

O’= D’- 2

D’=Duct Size

6

30

S11

1911

44

79

Hanger

O’= D’+ 19

D’=Duct Size

19

29S 3

4984

D’=Duct Size

O’

19

AS 2

44

Hanger

79

O’=D’- 2

D’=Duct Size

5

30

S 1911

44

Hanger

79

19O’=D’- 3

19S

D’=Duct Size D’+ 13D’+ 32

1325

4884

19O’= D’- 3

S

D’=Duct Size

19

8419

131

48

O’=D’- 2

D’=Duct Size

5

30

S 1911

44

Hanger

79

Frame & Border Type 3With• Flush Border• Concealed Mounting

Frame & Border Type 4With• Flange Border• Concealed Mounting

Frame & Border Type 6With• Plaster & Tile Mounting Frame• Flush Border• Concealed Mounting

Frame & Border Type 7AFrame & Border Type 7BBoth with• Plaster & Tile Mounting Frame• Flange Border• Concealed Mounting

Border Type 9ABorder Type 9BBoth with• Flange Border• Ceiling Hangers

Border Type 11With• Perimeter Plaster & Tile

Mounting Frame• Flush Border• Concealed Mounting

Border Type 12With• Spline Border• Ceiling Hangers

Border Type 15With• Flush Border• Ceiling Hangers

Border Type 16With• Curved Flange Border• Concealed Mounting• Equalizing Grid

Border Type 16 standard selections:MML-38 only1 slot: duct diameters 254, 356, 457, 559, 610mm2 slot: duct diameters 356, 457, 559, 610mm3 slot: duct diameters 457, 559, 610, 762mm4 slot: duct diameters 457, 559, 610, 762mm

2

Type A 0’9A 19 D’ + 169B 29 D’ + 35

Type A 0’7A 29 D’ + 197B 22 D’ + 6

Page 3: Submittal MD-MML 2-28-13 - Titus HVAC · PDF fileSubmittal MD-MML 2-28-13 All dimensions are in millimeters. Check if provided 90 Degree (Minimum) Larger than 90 degree. Specify Cut

D = Duct Size

O

C

O

D = Duct Size

C

O

D = Duct Size

C

End Fabrication

Overall Length for Various End Fabrications

Duct Dimensions D’ (Width) for Various Frame & Border Types

X End Border Y Open End Z End Cap

Frameand/orBorderType

X-X X-Y X-Z Y-Y Y-Z Z-Z

C O C O C O C O C O C O

1A, 1B, 9B D -35 D +19 D -17 D +10 D -16 D +11 D D D +2 D +2 D +3 D +3

2A, 4, 7A, 16 D -35 D +19 D -17 D +10 D -16 D +11 D D D +2 D +2 D +3 D +3

3, 6, 11 D -35 D D -17 D D -16 D +2 D D D +2 D +2 D +3 D +3

2B, 7B D -35 D +6 D -17 D +3 D -16 D +5 D D D +2 D +2 D +3 D +3

9A D -35 D D -17 D D -16 D +2 D D D +2 D +2 D +3 D +3

12, 15 D -17 D D -8 D D -6 D +2 D D D +2 D +2 D +3 D +3

Types 1A, 1B Types 2A, 2B, 4, 7A, 16 Types 3, 6, 11 Types 9A, 9B Types 12, 15MML/MMLR MML/MMLR MML/MMLR MML/MMLR MML/MMLR MML/MMLR MML/MMLR MML/MMLR MML/MMLR MML/MMLR MML/MMLR MML/MMLR MML/MMLR MML/MMLR MML/MMLR

37 38 39 37 38 39 37 38 39 37 38 39 37 38 39

S = 13 S = 19 S = 25 S = 13 S = 19 S = 25 S = 13 S = 19 S = 25 S = 13 S = 19 S = 25 S = 13 S = 19 S = 35

1 48 54 60 51 57 64 54 60 67 35 41 48 35 41 48

2 79 92 105 83 95 108 86 98 111 67 79 92 67 79 92

3 111 130 149 114 133 152 117 137 156 98 117 137 98 117 137

4 137 168 194 146 171 197 149 175 200 130 156 181 130 156 181

5 175 206 238 179 210 241 181 213 244 162 194 225 162 194 225

6 206 244 283 210 248 286 213 251 289 194 232 270 194 232 270

7 238 283 327 241 286 330 244 289 333 225 270 314 225 270 314

8 270 321 371 273 324 375 276 327 378 257 308 359 257 308 359

3

No.of

Slots

Y Y

Page 4: Submittal MD-MML 2-28-13 - Titus HVAC · PDF fileSubmittal MD-MML 2-28-13 All dimensions are in millimeters. Check if provided 90 Degree (Minimum) Larger than 90 degree. Specify Cut

Accessories (Optional) Check if provided

Optional Field Cut Diffuser (Unit includes one field spacer kit) MMLF-37 • 13mm Slot • Supply MMLRF-37 • 13mm Slot • ReturnMMLF-38 • 19mm Slot • Supply MMLRF-38 • 19mm Slot • ReturnMMLF-39 • 25mm Slot • Supply MMLRF-39 • 25mm Slot • Return

Optional Mitered CornerMMC-37• 13mm Slot MMC-38• 19mm SlotMMC-39• 25mm Slot

MP-SP DesignOptional

Ideal when the exact length of an MMLor MMLR diffuser is not known until it isbeing installed.

Standard factory cut diffusers can betrimmed as much as 152mm. If more than152mm is to be removed, use the optionalfield cut diffuser.

The field cut MML or MMLR diffuser is1829mm long, with the sides pre-punchedto assure the proper alignment of fieldinstalled spacers. These field installedspacers provide additional rigidity duringand after cutting.

Additional spacer kits available at extracost.

Note:• MMP and MMPI are available for allframes and border types.

• Standard nominal lengths are 610,914, 1219 and 1524mm.

• Request Submittal MD-MMP fordetails.

• Option MMP-MSP available with maxi-mum spread pattern.

Optional PlenumMMP-37 • 13mm Slot • Uninsulated MMPI-37 • 13mm Slot • InsulatedMMP-38 • 19mm Slot • Uninsulated MMPI-38 • 19mm Slot • InsulatedMMP-39 • 25mm Slot • Uninsulated MMPI-39 • 25mm Slot • Insulated

No.of

Slots1A, 1B 2A, 4 7A 2B, 7B 3, 6, 11 9A 9B 12, 15

O D O D O D O D O D O D O D1, 2 316 305 314 305 308 305 302 305 313 305 322 305 305 3053-8 621 610 619 610 613 610 606 610 618 610 627 610 610 610

Optional Blank-Offs MBLKS • Cold Rolled Steel • Fits over Neck MBLKV • Vinyl • Fits in Slot

• Standard lengths of diffuser sections are305mm, 610mm, 914mm, 1219mm, 1524mmand 1829mm.• Lengths greater than 1829mm are furnishedin multiple sections, the number and sizedetermined by the factory.

• Pattern controllers change direction andvolume of air flow. Maximum length is 914mm.Pattern controllers are furnished in multiplesections for diffuser longer than 914mm.• Mounting frames are cut to length andassembled in the field.

• Material is extruded aluminum with steelpattern controllers.

Standard Finish: #26 White border • Black pattern controllers.

General Description

Submittal MD-MML 2-28-13

All dimensions are in millimeters.

Check if provided90 Degree (Minimum)Larger than 90 degree. Specify

CutCut

lot Operator

lot Operator

®605 Shiloh Road • Plano, Texas 75074 • 972-212-4800

MD-1.0-S

All rights reserved. No part of this work may be reproduced or transmitted in any form or any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system without permission in writing from Air Distribution Technologies

Note: This submittal is meant to demonstrate general dimensions of this product. The drawing on this submittal are not meant to detail everyaspect of the product with exactness. Drawings are not to scale. TITUS reserves the right to make changes without written notice.