submersible level transmitter - gilsoneng.comsubmersible level transmitter perfect for sludge and...

1
SPECIFICATIONS Service: Compatible liquids. Wetted Materials: 316 SS, 316L SS, Buna-N, cable: ETFE or polyurethane. Accuracy: ±0.25% full scale (includes linearity, hysteresis, and repeatabili- ty). Temperature Limit: PBLT2: 0 to 200˚F (-18 to 93˚C), PBLTX: 0 to 176˚F (-18 to 80˚C). Compensated Temperature Range: PBLT2: 0 to 180°F (-18 to 82°C), PBLTX: 0 to 176°F (-18 to 80°C). Thermal Effect: ±0.02% FS/˚F. Pressure Limit: 2X full scale. Power Requirement: PBLT2: 13 to 30 VDC, PBLTX: 10 to 28 VDC. Output Signal: 4 to 20 mA DC, two wire. Response Time: 50 msec. Loop Resistance: 900 ohms. Electrical Connection: Wire pigtail. Mounting Orientation: Suspended in tank below level being measured. Weight: 4.3 lb (2.0 kg). Electrical Protection: PBLT2: Lightning and surge protection, PBLTX: none. Agency Approvals: PBLT2: None, PBLTX: CE, UL intrinsically safe for Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1. (According to control drawing 01-700797-00) APPLICATIONS • Wastewater: sludge pits, clarifiers, digesters; alum tanks; chemical storage tanks; oil tanks; lime slurry; slumps; reservoirs. Submersible Level Transmitter Perfect for Sludge and Slurries, Lightning Protected, Intrinsically Safe Series PBLT2 & PBLTX PBLT2 and PBLTX Submersible Level Transmitters are manufactured for years of trouble free service in the harshest applications. Both measure the height of liquid above the position in the tank referenced to atmospheric pres- sure. The transmitter consists of a piezoresistive sensing element, encased in a 316 SS housing. Perfect for wastewater and slurry applications with features to protect the unit from these demanding applications. Large diameter 316 SS di- aphragm seal is non-clogging and damage resistant to floating solids. The PBLT2 incorporates lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and light- ning ground strike transients (surge protection is not guaranteed and is not cov- ered by warranty). The PBLTX is UL approved intrinsically safe for use in hazardous locations when used with proper barrier. Units comes equipped with a 270-pound tensile strength shielded and vented cable. Ventilation tube in the cable automatically compensates for changes in at- mospheric pressure above the tank. The vent is protected with a maintenance free filter eliminating particulate or water droplets from entering the trans- ducer. FEATURES • Excellent chemical compatibility with 316 construction and ETFE cable • Lightning and surge protection on PBLT2 models • Maintenance free vent filter UL approved intrinsically safe on PBLTX models • Large diameter, non-clogging, damage resistant, 316 SS diaphragm seal 8-3/32 [205.58] 2-3/16 [55.56] BREATHER TUBE ø1 [25.40] 1/2 NPT SUBMERSIBLE CABLE 60˚ TYP ø1/4 x THRU [ø6.35 x THRU] ø3-7/16 [ø87.31] ø1/4 [ø6.35] x THRU ON A ø1-39/64 [ø40.88] B.C. 7-63/64 [202.80] 2-3/16 [55.56] Ø1-1/2 [Ø38.10] 1/2 NPT BREATHER TUBE SUBMERSIBLE CABLE PBLTX PBLT2 OPTIONS Intrinsically Safe Approval- Change model number from PBLT2 to PBLTX Custom ranges or Cable Lengths- Contact the factory for pricing. ACCESSORIES MTL5041, intrinsically safe galvanic isolator MTL7706, intrinsically safe zener barrier Cable Length ft (m) 40 (12.2) 40 (12.2) 60 (18.3) 60 (18.3) 40 (12.2) 40 (12.2) 60 (18.3) 60 (18.3) Model Number PBLT2-5-40 PBLT2-10-40 PBLT2-15-60 PBLT2-20-60 PBLT2-5-40-PU PBLT2-10-40-PU PBLT2-15-60-PU PBLT2-20-60-PU Range psi (ft wc) [m wc] 5 (11.54) [3.52] 10 (23.09) [7.04] 15 (34.63) [10.56] 20 (46.18) [14.08] 5 (11.54) [3.52] 10 (23.09) [7.04] 15 ( 34.63) [10.56] 20 (46.18) [14.08] Cable Type ETFE ETFE ETFE ETFE Polyurethane Polyurethane Polyurethane Polyurethane

Upload: others

Post on 04-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Submersible Level Transmitter - gilsoneng.comSubmersible Level Transmitter Perfect for Sludge and Slurries, Lightning Protected, Intrinsically Safe Series PBLT2 & PBLTX PBLT2 and PBLTX

VISIT OUR WEBSITES: www.dwyer-inst.com • www.dwyer-inst.co.uk • www.dwyer-inst.com.au 274

Leve

l

SPECIFICATIONSService: Compatible liquids.Wetted Materials: 316 SS, 316L SS, Buna-N, cable: ETFE orpolyurethane.Accuracy: ±0.25% full scale (includes linearity, hysteresis, and repeatabili-ty).Temperature Limit: PBLT2: 0 to 200˚F (-18 to 93˚C), PBLTX: 0 to 176˚F (-18 to 80˚C).Compensated Temperature Range: PBLT2: 0 to 180°F (-18 to 82°C),PBLTX: 0 to 176°F (-18 to 80°C).Thermal Effect: ±0.02% FS/˚F.Pressure Limit: 2X full scale.Power Requirement: PBLT2: 13 to 30 VDC, PBLTX: 10 to 28 VDC.Output Signal: 4 to 20 mA DC, two wire.Response Time: 50 msec.Loop Resistance: 900 ohms.Electrical Connection: Wire pigtail.Mounting Orientation: Suspended in tank below level being measured.Weight: 4.3 lb (2.0 kg).Electrical Protection: PBLT2: Lightning and surge protection, PBLTX:none.Agency Approvals: PBLT2: None, PBLTX: CE, UL intrinsically safe forClass I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III,Div. 1. (According to control drawing 01-700797-00)

APPLICATIONS• Wastewater: sludge pits, clarifiers, digesters; alum tanks; chemical

storage tanks; oil tanks; lime slurry; slumps; reservoirs.

Submersible Level TransmitterPerfect for Sludge and Slurries, Lightning Protected, Intrinsically Safe

SeriesPBLT2

& PBLTX

PBLT2 and PBLTX Submersible Level Transmitters are manufactured foryears of trouble free service in the harshest applications. Both measure theheight of liquid above the position in the tank referenced to atmospheric pres-sure. The transmitter consists of a piezoresistive sensing element, encased in a316 SS housing. Perfect for wastewater and slurry applications with features toprotect the unit from these demanding applications. Large diameter 316 SS di-aphragm seal is non-clogging and damage resistant to floating solids.

The PBLT2 incorporates lightning and surge protection utilizing dual arrestortechnology, grounded to case, eliminating both power supply surges and light-ning ground strike transients (surge protection is not guaranteed and is not cov-ered by warranty). The PBLTX is UL approved intrinsically safe for use inhazardous locations when used with proper barrier.

Units comes equipped with a 270-pound tensile strength shielded and ventedcable. Ventilation tube in the cable automatically compensates for changes in at-mospheric pressure above the tank. The vent is protected with a maintenancefree filter eliminating particulate or water droplets from entering the trans-ducer.

FEATURES• Excellent chemical compatibility with 316 construction and ETFE cable• Lightning and surge protection on PBLT2 models• Maintenance free vent filter• UL approved intrinsically safe on PBLTX models• Large diameter, non-clogging, damage resistant, 316 SS diaphragm seal

8-3/32[205.58]

2-3/16[55.56]

BREATHER TUBE

ø1 [25.40]1/2 NPT

SUBMERSIBLECABLE

60˚TYP

ø1/4 x THRU[ø6.35 x THRU]

ø3-7/16[ø87.31]

ø1/4 [ø6.35] x THRUON A ø1-39/64 [ø40.88] B.C.

7-63/64[202.80]

2-3/16[55.56]

Ø1-1/2[Ø38.10]

1/2 NPT

BREATHER TUBE

SUBMERSIBLECABLE

PBLTX

PBLT2

OPTIONSIntrinsically Safe Approval- Change model number fromPBLT2 to PBLTXCustom ranges or Cable Lengths- Contact the factory forpricing.

ACCESSORIESMTL5041, intrinsically safe galvanic isolatorMTL7706, intrinsically safe zener barrier

Cable Lengthft (m)40 (12.2)40 (12.2)60 (18.3)60 (18.3)40 (12.2)40 (12.2)60 (18.3)60 (18.3)

Model Number

PBLT2-5-40PBLT2-10-40PBLT2-15-60PBLT2-20-60PBLT2-5-40-PUPBLT2-10-40-PUPBLT2-15-60-PUPBLT2-20-60-PU

Range psi (ft wc) [m wc]5 (11.54) [3.52]10 (23.09) [7.04]15 (34.63) [10.56]20 (46.18) [14.08]5 (11.54) [3.52]10 (23.09) [7.04]15 ( 34.63) [10.56]20 (46.18) [14.08]

Cable Type

ETFEETFEETFEETFEPolyurethanePolyurethanePolyurethanePolyurethane

p274:left tabs copy 7/11/08 4:08 PM Page 1