Subject: Equipment under SOLAS Chapter II-1. Construction Product: M ED /8.1 Water Level D etectors Producer Product and Type Details of Approval Specified Standard Remarks Cert. N o. 1 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract. http://www.cdlive.lr.org/information/ Guangzhou Fokstone Automation Co., Ltd., 6/F, N o.8 Baojv Street, Guangzhou Economic & , Technological Development Zone, Guangzhou, 510730, China, People's Republic of. A.1/ 8.1 Water level detectors Type IWS series IEC 60092-504 (2001) IEC 60529 (2001) IM O Res.M SC.188(79) IM O M SC.1/ Circ.1291 Expires: 25 February 2018 M ED 1300004 PSM Instrumentation Ltd, Burrell Road, Haywards Heath, West Sussex, RH 16 1TW, United Kingdom (UK). Bulksafe bulk carrier water level detector system Water ingress alarm system IEC 60092-504 (2001), IEC 60529 (2001), IM O Res. M SC.188(79), IM O M SC.1/ Circ. 1291 Expires: 7 October 2017 M ED 1200012 Sealantern Electronics Co. Ltd., No. 6 Zhuyuan Road, Huayuan Industrial Park, Tianjin 300384, China, People's Republic of. Water ingress alarm system Type SLT-08C IEC 60092-504 (2001), IEC 60529 (2001), IM O Res. M SC.188(79), IM O M SC.1/ Circ. 1291 Expires: 3 October 2017 M ED 1200010 Water ingress alarm system Type SLT-08D IEC 60092-504 (2001), IEC 60529 (2001), IM O Res. M SC.188(79), IM O M SC.1/ Circ. 1291 Expires: 3 October 2017 M ED 1200011

Upload: others

Post on 16-Apr-2020

28 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Equipment under SOLAS Chapter I I -1. Construction Product: M ED/8.1 Water Level Detectors

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

1 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Guangzhou Fokstone Automation Co., Ltd., 6/F, No.8 Baojv Street, Guangzhou Economic &, Technological Development Zone, Guangzhou, 510730, China, People's Republic of.

A.1/ 8.1 Water level detectors Type IWS series

IEC 60092-504 (2001) IEC 60529 (2001) IMO Res.MSC.188(79) IMO MSC.1/ Circ.1291

Expires: 25 February 2018

MED 1300004

PSM Instrumentation Ltd, Burrell Road, Haywards Heath, West Sussex, RH16 1TW, United Kingdom (UK).

Bulksafe bulk carrier water level detector system

Water ingress alarm system IEC 60092-504 (2001), IEC 60529 (2001), IMO Res. MSC.188(79), IMO MSC.1/ Circ. 1291

Expires: 7 October 2017

MED 1200012

Sealantern Electronics Co. Ltd., No. 6 Zhuyuan Road, Huayuan Industrial Park, Tianjin 300384, China, People's Republic of.

Water ingress alarm system Type SLT-08C

IEC 60092-504 (2001), IEC 60529 (2001), IMO Res. MSC.188(79), IMO MSC.1/ Circ. 1291

Expires: 3 October 2017

MED 1200010

Water ingress alarm system Type SLT-08D

IEC 60092-504 (2001), IEC 60529 (2001), IMO Res. MSC.188(79), IMO MSC.1/ Circ. 1291

Expires: 3 October 2017

MED 1200011

Page 2: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Equipment under SOLAS Chapter I I -1. Construction Product: M ED/8.1 Water Level Detectors

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

2 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai Rongde Engineering Equipment Co., Ltd., RM 1401, Xingyu Building No.1 - 1695, Pudong Ave, Shanghai, China, People's Republic of.

RDHL-D Water Level Detector System Water Level Detection Alarm System IEC 60092-504 (2001) IEC 60529 (2001) IMO MSC.188(79) IMO MSC.216(82) Annex 2 Reg.25 SOLAS Regulation XII/ 12

Expires: 24 February 2018

MED 1300003

Page 3: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.1 PRIM ARY DECK COVERINGS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

3 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Amorim Cork Composites, Rua de M eladas, 260, M ozelos - VFR, 4536-902, Portugal.

Fire Resisting Primary Deck Covering – Type “ ACM30 - Composite material specially designed to be used as an exterior primary deck covering for levelling and fairing”

PRIM ARY DECK COVERING IMO Res. MSC.307 (88) – (2010 FTP Code), Annex 1, Part 5 MSC / Circ.1120

Expires: 20 April 2022

MED 1750072

Dalian M ingyang Deck Covering Co., Ltd., No. 468-8, Shuangdao Wan Road, Lvshunkou, Dalian, China, People's Republic of.

Fire Resisting Material – Type :” GS-B” Primary Deck Covering

PRIM ARY DECK COVERING M ATERIAL

IMO Res. MSC.61(67) – (FTP Code) Annex 1 Part 2 and Part 6 IMO MSC/ Circ.1120 IMO Res.MSC.307(88) – (2010 FTP Code) Section 8

Expires: 30 October 2020

MED 1650060

Fire Resisting Material - Type: “ MS-800” Primary Deck Covering

Primary Deck Covering Material IMO Res. MSC.61(67) – (FTP Code) Annex 1 Part 2 and Part 6 IMO MSC/ Circ.1120 IMO Res.MSC.307(88) – (2010 FTP Code) Section 8

Expires: 30 October 2020

MED 1650061

Fire Resisting Material - Type: “ MS-1200” Primary Deck Covering

Primary Deck Covering Material IMO Res. MSC.61(67) – (FTP Code) Annex 1 Part 2 and Part 6 IMO MSC/ Circ.1120 IMO Res.MSC.307(88) – (2010 FTP Code) Section 8

Expires: 30 October 2020

MED 1650062

Fire Resisting Primary Deck Covering – Type:” MS-600 Super Light Primary Deck Covering” .

PRIM ARY DECK COVERING IMO Res. MSC.307 (88) - (2010 FTP Code), Annex 1, Part 5 and Part 2.

Expires: 17 April 2021

MED 1650132

Page 4: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.1 PRIM ARY DECK COVERINGS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

4 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Durastic Ltd., Unit 47, Cuthbert Court, Bede Industrial Estate, Jarrow, Tyne & Wear, NE32 3HG, United Kingdom (UK).

Fire Resisting Material – Type “ Durastic S450 Epoxy” and “ Durastic S776 Epoxy” Deck Covering

Primary Deck Covering Material Not Capable of Producing Excessive Quantities of Smoke And Toxic Products of Combustion

IMO Fire Test Procedures Code, Annex 1, Part 6 and Part 2

Expires: 17 November 2012

MED 0750293 And

USCG Module B No:

164.106/ EC0038

Fire Resisting Material -Type “ Durastic Decorflake Epoxy Flooring “ and “ S405 FR Epoxy” Deck Covering

Primary Deck Covering Material Not Capable of Producing Excessive Quantities of Smoke And Toxic Products of Combustion

IMO Fire Test Proceudures Code Annex 1, Part 2 and Part 6

Expires: 17 November 2012

MED 0750294 And

USCG Module B No:

164.106/ EC0038

Fire-Resisting Material – Type “ Durastic S229 Underlay” Deck Covering

Primary Deck Covering IMO Res.MCS.61(67)-(FTP Code) Annex 1 Part 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8 and Annex 1 Part 5

Expires: 5 September 2019

MED 1450240/ M1

Page 5: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.1 PRIM ARY DECK COVERINGS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

5 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Durastic Ltd. ...continued Fire Resisting Material – Type: “ Durastic Lightweight Underlay”

PRIM ARY DECK COVERING M ATERIAL NOT CAPABLE OF PROUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 2 and Part 6 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 31 July 2020

MED 1550162

Helder & M ay B.V., M oezelweg 202, 3198 LS Rotterdam-Europoort, Netherlands, The.

Fire Resisting Material: Type “ NAUTEC FS” Deck Covering Material

PRIM ARY DECK COVERING M ATERIAL NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE AND TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 5 and Annex 2

Expires: 9 March 2019

MED 1450195

J D Jones & Company (Bombay) Pvt Ltd, Ama House, B K M arg, Behind Strand Cinema, Colaba, M umbai-400005, India.

Fire Resisting Material – Type: “ Syncolite” primary deck covering material

Primary Deck Covering Material Not Capable Of Producing Excessive Quantities Of Smoke & Toxic Products Of Combustion

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 2 and Part 5

Expires: 14 April 2021

MED 1650128

Leeson Polyurethanes Ltd, Hermes Close, Tachbrook Park, Warwick, CV34 6NW, United Kingdom (UK).

Fire Resisting Material – Type: “ Leesongrip PU4018 Polyurethane Anti-Skid System”

Primary deck covering material not capable of producing excessive quantities of smoke and toxic products of combustion

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 2 and Part 6 IMO MSC/ Circ 1120 IMO Res. MSC307(88) – (2010 FTP Code) Section 8

Expires: 20 May 2018

MED 1350092

Fire Resisting Material – Type: “ Safegrip Polyurethane Anti-Skid System”

Primary deck covering material not capable of producing excessive quantities of smoke and toxic products of combustion

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 2 and Part 6 IMO MSC/ Circ 1120 IMO Res. MSC307(88) – (2010 FTP Code) Section 8

Expires: 20 May 2018

MED 1350093

Page 6: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.1 PRIM ARY DECK COVERINGS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

6 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Tianjin Tanggu Deck Covering Factory, 3 Erhao Road, Xingang, Binhaixinqu, Tianjin 300456, China, People's Republic of.

Fire Resisting Material – “ TG-C Super-light Basic Deck Coating”

PRIM ARY DECK COVERING M ATERIAL AND NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE AND TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1 part 6 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010FTP Code) Section 8.

Expires: 15 November 2019

MED 1550018

Torginol-Teollisuuslattiat Oy, Billskogintie 31, 02580 Siuntio, Finland.

Fire Resisting Material - Type: “ Torginol LECAPLAST” Primary Deck Covering Material

Primary deck covering material IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 6 and Annex 2 IMO MSC/ Circ 1120

Expires: 16 March 2015

MED 1050382

Page 7: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.1 PRIM ARY DECK COVERINGS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

7 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Torginol-Teollisuuslattiat Oy ...continued

Fire Resisting Material - Type: “ Epox-Torginol XB - TOPCOAT” Primary Deck Covering Material

Primary deck covering material IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 6 and Part 2 IMO MSC/ Circ 1120

Expires: 16 March 2015

MED 1050383

Fire Resisting Primary Deck Covering Material – Type: “ Epox Deckfill”

PRIMARY DECK COVERING MATERIAL NOT CAPABLE OF PROUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 6 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 18 January 2021

MED 1650117

Page 8: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.10 NOZZLES FOR FIXED PRESSURE WATER SPRAYING FIRE EXTINGUISHING SYSTEM S FOR M ACHINERY SPACE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

8 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Knaack & Jahn Schiffbau GmbH, Uffelnsweg 10, 20539 Hamburg, Germany.

Fixed Fire Extinguishing System Component, – Type: “ MK-6” Nozzle head for Machinery Spaces of Category A and Cargo Pump Rooms with a deckhead height not exceeding 10 metres and maximum enclosure volume of 2862m3, equivalent to SOLAS II-2/ 10.4 & FSS Code, Chapter 7-2-2 (limited to nozzle head and their performance).

Pressure Water-Spraying System IMO MSC/ Circ. 1165 as amended by MSC.1/ Circ. 1269 and MSC.1/ Circ. 1386

Expires: 10 October 2016

MED 1150269

Ultra Fog AB, Backa Strandgata 18, Hisings Backa, 422 46, Sweden.

Fixed Fire Extinguishing System – Type: “ Ultra Fog Wet pipe Automatic Sprinkler System” for Closed Ro-Ro Spaces and Special Category Spaces for 5.0m and 2.5m deck heights

PRESSURE WATER-SPRAYING SYSTEM

IMO MSC.1/ Circ.1272, as amended by MSC.1/ Circ. 1430

Expires: 31 July 2018

MED 1450076/ M1

VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg, Denmark.

Fixed Fire Extinguishing System Component – Type: “ Atlantic” Nozzle head for Machinery Spaces of Category A and Cargo Pump Rooms with a deckhead height not exceeding 10 metres and maximum enclosure volume of 2862m3, equivalent to SOLAS II-2/ 10.4 & FSS Code, Chapter 7-2-2 (limited to nozzle head and their performance)

PRESSURE WATER-SPRAYING SYSTEM

IMO MSC/ Circ. 1165 as amended by MSC.1/ Circ. 1269 and MSC.1/ Circ. 1386

Expires: 10 October 2021

MED 1750002

Page 9: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

9 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

3 M aj Tibo d.d., Dalmatinskih Brigada 17, 51211 M atulji, Croatia.

Fire Resisting Ceiling Inspection Hatch – Type ‘’SSP-2’’

B-0 CEILING FIXTURE IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 13 February 2017

MED 1250073 And

USCG Module B number:

164.110/ EC0038

BBM G Energy Saving M aterial & Technology Company, Gaojing #2, Chaoyang District, Beijing, 100123, China, People's Republic of.

Steel Deck Insulated on the underside with Type: “ CY-120” Mineral Wool Insulation (40mm thick, 120 kg/ m³ density)

A-60 DECK IMO Res. MSC.307(88)-(2010 FTP Code) Annex 1 Part 3

Expires: 14 June 2020

MED 1550144

Steel Bulkhead Insulated on one side with Type: “ CY-120” Mineral Wool Insulation (60mm thick, 120 kg/ m³ density)

A-60 BULKHEAD IMO Res. MSC.307(88)-(2010 FTP Code) Annex 1, Part 3

Expires: 14 June 2020

MED 1550145

Fire Resisting “ A-60” Class Deck - Type: “ CY120”

A-60 DECK IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1 Part 3

Expires: 12 October 2020

MED 1550236/ M1

Cenes, Postbus 380, 9200 AJ Drachten, Netherlands, The.

Fire Resisting ‘A’ Class Deck – Type: “ A-60 Steel Deck insulated on topside w ith ‘Rockwool Marine Slab 758’ and foil and Anhydrite finish”

A-60 Deck IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 8 December 2015

USCG Module B number: 164.105/ EC0038 MED 1050359

Page 10: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

10 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Dalian M ingyang Deck Covering Co., Ltd., No. 468-8, Shuangdao Wan Road, Lvshunkou, Dalian, China, People's Republic of.

Fire Resisting ‘A’ Class Steel Deck insulated on upper side – Type “ Guanzhou A-60MU” Floating Floor

A-60 DECK IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 16 March 2019

MED 1450114

Steel Deck Insulated on topside w ith “ A60-TU covering”

A-60 DECK IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 3 March 2021

MED 1650185

Damen Shipyards Bergum, Damsingel 4 (Industrieterrein Zuid), 9262 NC Suameer, Netherlands, The.

Fire Resisting ‘A’ Class Deck – Type: “ A-60 Steel Deck insulated on topside w ith ‘Rockwool Marine Slab 758’ and foil and Anhydrite finish”

A-60 Deck IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 8 December 2015

And USCG Module

B number: 164.105/ EC003

8 MED 1050360

Page 11: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

11 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Durastic Ltd., Unit 47, Cuthbert Court, Bede Industrial Estate, Jarrow, Tyne & Wear, NE32 3HG, United Kingdom (UK).

Fire Resisting Deck – Type: “ Steel deck insulated on topside with ‘S413 Insulation Compound’ (37mm thick, 750-800 kg/ m³ density)”

A-60 DECK IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 17 November 2017

MED 1250250/ M1

Elvik S.A., 12 Filellinon Street, Piraeus 185 36, Greece.

Fire Resisting Bulkhead Panel System – Type: “ 50mm B-15 Panel”

B-15 BULKHEAD IMO Resolution MSC. 61(67) - Fire Test Procedures Code, Annex 1, Part 3; IMO MSC/ Circ 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 2 March 2022

MED 1750037

B-15 Fire Resisting Suspended Ceiling – Type: “ 45mm B-15 Panel” and an A-30 Deck fire rating

B-15 CEILING IMO Resolution MSC. 61(67) - Fire Test Procedures Code, Annex 1, Part 3; IMO MSC/ Circ 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 2 March 2022

MED 1750038

FINCANTIERI, Cantieri Navali I taliani S.p.A., Via Genova, 1-34121, Trieste, I taly.

A-15 Class steel deck with type: “ Saint Gobain ISOVER ULTIMATE U MPN 36 (60mm, 36kg/ m3)” mineral wool insulation fitted on the steel plate on the underside

A-15 DECK IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) 2010 FTP Code, Section 8

Expires: 10 April 2019

MED 1450082

A-15 Class steel deck with type: “ Rockwool SeaRox SL 740 (60mm, 45kg/ m3)” mineral wool insulation fitted on the steel plate on the underside

A-15 DECK IMO Res. MSC.307 (88)-(2010 FTP Code), Annex 1, Part 3

Expires: 10 April 2019

MED 1450083

Page 12: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

12 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

A-15 Class steel deck with type: “ PAROC Marine Fire Slab 40 (65mm, 40kg/ m3)” mineral wool insulation fitted on the steel plate on the underside

A-15 DECK IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8 (Period of Grace)

Expires: 10 April 2019

MED 1450084

Jingjiang Dakeyuan New M aterials Engineering Co Ltd, No. 12 Xinsan Road, Chengbei Park, Economic Development Zone, Jingjiang City, Jingjiang Province, 214500, China, People's Republic of.

Fire-Resisting ‘A’ Class Deck – Type “ DKY-3” Light Floating Fireproof Deck Covering

A-60 DECK IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 21 January 2021

MED 1650037

Page 13: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

13 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jingjiang Dakeyuan New M aterials Engineering Co Ltd ...continued

Fire-Resisting ‘A’ Class Deck – Type “ DKY-4” Light Fireproof Deck Covering

A-60 DECK IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 21 January 2021

MED 1650038

M cAllister M ills Inc., P.O. Box 590, 173 Rainbow Circle, Independence, Virginia, 24348, United States of America (USA).

Steel deck insulated on the underside w ith foil encapsulated ceramic fibre insulation blanket (38mm thick, 96kg/ m3 density) type: “ Alvex PF”

A-60 DECK IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 18 August 2016

MED 1150227

M ercan Gemicilik San ve Tic A.S, Organize Deri Sanayi Bölgesi 7 Yol, F7 Parsel, Tuzla, Istanbul, Turkey.

Steel deck insulated on topside with “ Izocam Marine Firebatts 150” mineral wool- Type: “ A-30 Floating floor” ”

A-30 DECK

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 14 February 2021

MED 1550122/ M1

Steel Deck Insulated on the Upperside– Type: “ Mercan A-60 Class Floating Floor”

A-60 DECK IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 14 February 2020

MED 1550128/ M1

M organ Kailong (Jingmen) Thermal Ceramics CO., LTD., 20-1# Quankou Road, Jingmen City, Hubei Province, 448032, China, People's Republic of.

Steel Bulkhead insulated on one side with “ Kaowool FireMaster Blanket” (55mm thickness on bulkhead and 25mm on stiffeners, 96kg/ m3 density)

A-60 BULKHEAD IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8

Expires: 1 November 2019

MED 1550224

Page 14: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

14 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Steel Bulkhead insulated on fire exposed side with “ Kaowool Firemaster Blanket” (38mm thick,96 kg/ m3 density)

A-60 BULKHEAD IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8

Expires: 1 November 2019

MED 1550225

Steel Deck insulated on underside with “ Kaowool Firemaster Blanket” (38mm thick, 96 kg/ m3 density)

A-60 DECK IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8

Expires: 1 November 2019

MED 1550226

Page 15: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

15 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Oy Lautex Ab, P.O Box 58, FIN-03101 Nummela, Finland.

Fire Resisting Deck – Type: “ NST 300 Ceiling / A-0 Deck”

A-15 Deck IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 11 April 2016

MED 1150111

Fire Resisting ‘A’ Class Deck – Type: “ Self-supporting NBT-300” with fixtures

A-15 DECK IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 9 March 2018

MED 1350007

Fire Resisting ‘A’ Class Deck – Type: “ HT-300”

A-15 Deck IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 12 February 2018

USCG 164.110/ EC0038 MED 1350018

Fire Resisting Ceiling – Type “ NBT-300”

A-30 Deck IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 12 March 2018

MED 1350031

PANELSHIP, SLU, Poligono Industrial de A Lomba, Parroquia de Areas, Ponteareas, 36861, Ponteveda, Spain.

Fire Resisting Division, Bulkhead Panel System – Type: “ Panel PC A60” Panel System

A60 Bulkhead IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 and Annex 2 IMO MSC/ Circ.1120

Expires: 1 October 2017

MED 1250187

Principle Security Ltd, Unit 6, Old Fieldhouse Lane, Huddersfield, HD2 1AG, United Kingdom (UK).

A60 Equivalent Fire Resisting Glazed Partition Type: “ PFSL A60 Fire Resistant Glazed and Facade System”

Non Load Bearing Glazed Partition (Standard Fire Test)

IMO Resolution MSC.61(67) – (FTP Code) Annex, 1, Part 2 and Part 5, and Annex 2 IMO MSC/ Circ.1120

Expires: 17 January 2015

MED 1050185 And USCG Module B No: 164.108/ EC0038

Page 16: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

16 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Promat Research & Technology Centre nv, Bormstraat 24, B-2830 Tisselt, Belgium.

Fire Resisting Bulkhead Panel System – Type: “ A-60 Class Double sided – Aluminium Structures”

A-60 BULKHEAD IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 27 August 2018

MED 1450022

Rockwool Limited, Pencoed, Bridgend, Wales, CF35 6NY, United Kingdom (UK).

Steel Bulkhead Insulated On One Side With “ Rockwool Marine Firebatt 2000 or C Liner” (75 mm thick, 100 kg/ m3 density)

A-60 Bulkhead IMO Resolution MSC.61(67) – (FTP Code) Annex, 1, Part 3 and Annex 2 IMO MSC/ Circ.1120

Expires: 16 January 2015

MED 1050204 And

USCG Module B number:

164.108/ EC0038

Page 17: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

17 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Rockwool Limited ...continued

Steel Deck Insulated On Underside With “ Rockwool Marine Firebatt 2000 or C Liner” (40 mm thick, 100 kg/ m3 density)

A-60 Deck IMO Resolution MSC.61(67) – (FTP Code) Annex, 1, Part 3 and Annex 2 IMO MSC/ Circ.1120

Expires: 16 January 2015

MED 1050205

And USCG

Module B number:

164.105/ EC0038

Steel Bulkhead Insulated On One Side With “ Rockwool Marine Firebatt 2000 or C Liner” (40 mm thick, 100 kg/ m3 density)

A-30 Bulkhead IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 and Annex 2 IMO MSC/ Circ.1120

Expires: 16 January 2015

MED 1050206 And

USCG Module B number:

164.108/ EC0038

Steel Deck Insulated On Underside With “ Rockwool Marine Firebatt 2000 or C Liner” (25 mm thick, 100 kg/ m3 density)

A-30 Deck IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 and Annex 2 IMO MSC/ Circ.1120

Expires: 16 January 2015

MED 1050207

And USCG

Module B number:

164.105/ EC0038

Saint-Gobain ISOVER G+H AG, Buergermeister- Gruenzweig-Strasse 1,, Ludwigshafen, D-67059, Germany.

Fire Resisting ‘A’ Class Aluminium Deck – Type: “ ULTIMATE A-60 Deck – Aluminium”

A-60 DECK IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 31 March 2019

MED 1450069/ M1

Page 18: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

18 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting ‘A’ Class Aluminium Bulkhead – Type: “ ULTIMATE A-60 Bulkhead - Aluminium”

A-60 BULKHEAD IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 31 March 2019

MED 1450071

Fire Resisting ‘A’ Class Aluminium Deck – Type: “ ULTIMATE A-60 Deck – Aluminium Single Layer”

A-60 DECK IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 31 March 2019

MED 1450072

Page 19: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

19 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

SBA Interior Ltd, Hallsnasintie 99, FIN-10360 M ustio, Finland.

Fire Resisting Ceiling - Type: “ JMC 1 Ceiling B-15”

B-15 Ceiling IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 29 May 2017

USCG Module B number:

164.110/ EC0038

MED 1250154

Fire Resisting Ceiling - Type: “ JMC 1 Ceiling B-15”

A-30 Deck IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 29 May 2017

USCG Module B number:

164.105/ EC0038

MED 1250155

Tianjin Tanggu Deck Covering Factory, 3 Erhao Road, Xingang, Binhaixinqu, Tianjin 300456, China, People's Republic of.

Steel Deck insulated on topside w ith “ TG-II” Light Fire Resisting Deck Coating” (overall nominal thickness 40mm)

A-60 Deck IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 16 January 2020

MED 1550015

Fire Resisting Material - Primary Deck Covering - Type: “ TG-I”

Material Having Low Flame Spread Characteristics

IMO Resolution A.653(16) Expires: 15 November 2019

MED 1550016

Unifrax Limited, M ill Lane, Rainford, St. Helens, M erseyside, WA11 8LP, United Kingdom (UK).

Fire Resisting ‘A’ Class Deck – Type: “ FyreWrap LT Blanket Insulated Aluminium Deck”

A30 DECK IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 3 April 2018

MED 1350045

Page 20: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

20 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting ‘A’ Class Deck – Type: “ FyreWrap LT Blanket insulated Aluminium Deck”

A60 Deck IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 24 April 2018

MED 1350056

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 24 April 2018

MED 1350057

Fire Resisting ‘A’ Class Deck – Type: “ FyreWrap LT Blanket insulated Aluminium Bulkhead” for Restricted Applications w ith Insulation on Fire Exposed Side

A60 Bulkhead IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 24 April 2018

MED 1350058

Fire Resisting ‘A’ Class Deck – Type: “ FyreWrap LT Blanket insulated Steel Deck”

A30 Deck IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 24 April 2018

MED 1350059

Page 21: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

21 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Unifrax Limited ...continued Fire Resisting ‘A’ Class Deck – Type: “ FyreWrap LT Blanket insulated A60 Steel Deck”

A60 Deck IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 11 August 2018

MED 1350108

Fire Resisting Load Bearing Aluminium Bulkhead Insulated on the Fire Exposed Side with Type: “ Load Bearing Fire-Resisting Bulkhead 60” system for High-Speed Craft using “ FyreWrap LT” AES wool insulation

LOAD BEARING FIRE-RESISTING BULKHEAD 60

IMO Resolution MSC.45(65) and Res.MSC.61(67) – FTP Code, Part 11, 2000 Amendments in Res.MSC.101(73). MSC/ Circ.1120. IMO Res.MSC.307(88) - 2010 FTP Code, under Section 8

Expires: 18 July 2018

MED 1350142

Steel Bulkhead Insulated on one side with Type: A-30 Class “ FyreWrap LT” AES wool insulation system

A-30 BULKHEAD (STANDARD FIRE TEST)

IMO Resolution MSC.307(88) - (2010 FTP Code) Annex 1, Part 3

Expires: 24 October 2018

MED 1350150

Steel Bulkhead Insulated on the fire exposed side with Type: A-60 Class “ FyreWrap LT” AES wool insulation system for Restricted Applications

A-60 BULKHEAD (STANDARD FIRE TEST)

IMO Resolution MSC.307(88) - (2010 FTP Code) Annex 1, Part 3

Expires: 24 October 2018

MED 1350152

Steel Bulkhead Insulated on the fire exposed side with Type: A-30 Class “ FyreWrap LT” AES wool insulation system for Restricted Applications

A-30 BULKHEAD (STANDARD FIRE TEST)

IMO Resolution MSC.307(88) - (2010 FTP Code) Annex 1, Part 3

Expires: 24 October 2018

MED 1350153

Fire Resisting ‘A’ Class Bulkhead - Type “ FyreWrap LT Blanket”

A-60 BULKHEAD IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 1 October 2019

MED 1450199/ M1

Fire-Resisting ‘A’ Class Bulkhead – Type “ FyreWrap LT Blanket”

A-60 BULKHEAD IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 16 February 2022

MED 1750016

Page 22: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11a 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'A' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

22 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Young Nam M arine M achinery Ind. Co. Ltd, #542-10 An Dong, Gimhae-City, Kyung Nam, 621-914, Korea, Republic of.

Fire Resisting Deck Hatch - Type: “ YN-WEH-A60”

Deck Hatch A-60 IMO Res. MSC61(67) (FTP Code) Annex 1, Part 3 IMO MSC/ Circ. 1120

Expires: 12 August 2017

USCG Module B

No: 164.105/ EC0

038 MED

1250239

Page 23: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

23 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

3 M aj Tibo d.d., Dalmatinskih Brigada 17, 51211 M atulji, Croatia.

Fire Resisting Panel Ceiling System - Type: “ TIBO-SSP-2 B-0”

B-0 Ceiling IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 1 March 2015

MED 1050109 And

USCG Module B No:

164.110/ EC0038

B-15 Class Fire Resisting Division, Bulkhead Panel System – Type: “ B-15 Class Bulkhead – Acoustic Panel”

B-15 Bulkhead IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 2 July 2016

MED 1150180

Burgess Architectural Products Ltd, Brookfield Road, Hinckley, Leicestershire, LE10 2LL, United Kingdom (UK).

Fire-Resisting Ceiling System – Type “ Burgess Clip-in Tiles”

B-15 Ceiling

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 3 December 2018

MED 1450119

DK Technology Co, 110-13 Ugye-Li, Sangdong-M yun, Gimhae City, Gyeongnam, Korea, Republic of.

B-0 Class Fire Resisting Division, Bulkhead Panel System – Type: “ DK-W25”

B-0 BULKHEAD IMO Res. MSC.61(67) - (FTP Code) Annex 1 Part 3 and Annex 2 IMO MSC/ Circ 1120

Expires: 25 January 2016

MED 1150044

B-0 Class Fire Resisting Division, Ceiling Panel System – Type: “ DK-C25”

B-0 CEILING IMO Res. MSC.61(67) - (FTP Code) Annex 1 Part 3 and Annex 2 IMO MSC/ Circ 1120

Expires: 25 January 2016

MED 1150045

B-15 Class Fire Resisting Division, Bulkhead Panel System – Type: “ DK-W50”

B-15 BULKHEAD IMO Res. MSC.61(67) - (FTP Code) Annex 1 Part 3 and Annex 2 IMO MSC/ Circ 1120

Expires: 25 January 2016

MED 1150046

Page 24: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

24 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Elvik S.A., 12 Filellinon Street, Piraeus 185 36, Greece.

Fire Resisting Bulkhead Panel System – Type: “ 34mm B-15 Panel”

B-15 BULKHEAD IMO Resolution MSC. 61(67) Fire Test Procedures Code, Annex 1, Part 3; IMO MSC/ Circ 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 2 March 2022

MED 1750035

Fabryka M ebli Okretowych FAM OS Sp z.o.o, ul Gdanska 37, 83-200 Starogard, Gdanski, Poland.

Fire Resisting Bulkhead – Type: “ Acoustic B15-50 to B-13-046 rev A”

B-15 Bulkhead IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 10 August 2010

MED 0550249/ M1

And USCG Module

B No: 164.108/ EC003

8

Page 25: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

25 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fabryka M ebli Okretowych FAM OS Sp z.o.o ...continued

Fire Resisting Ceiling – Type: “ Famos B15 Ceiling T/ SP-004”

B-15 Ceiling IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 10 August 2010

MED 0550250/ M1

And USCG

Module B No:

164.110/ EC0038

Fire Resisting Ceiling – Type: “ Famos Self Supporting B15 Ceiling B-13-500”

B-15 Ceiling IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 10 August 2010

MED 0550251

And USCG

Module B No:

164.110/ EC0038

Fire Resisting Bulkhead – Type: “ B15-50 to TT/ PD-001” Panel System

B-15 Bulkhead IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 12 February 2011

MED 0650030

And USCG

Module B No:

164.108/ EC0038

Fire Resisting Ceiling Type: “ Famos B15 Ceiling TT/ SL-004” w ith Fixtures

B-15 Ceiling IMO Res. MSC. 61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 13 March 2016

MED 1150056

Page 26: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

26 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Bulkhead Panel System – Type: “ According to Famos Drawings No:P-121-302, S/ P-121-302”

B-15 BULKHEAD IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 2 March 2016

MED 1150076

Fire Resisting Bulkhead – Type: “ B15-50 Bulkhead”

B-15 Bulkhead IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 2 March 2016

MED 1150084

Fire Resisting Bulkhead – Type: “ B15-25 Lining Wall S/ B-22-005” panel system

B-15 Bulkhead IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 27 March 2016

MED 1150085

Fire Resisting Ceiling – Type: “ Famos B15 Class Ceiling TT/ KS-001”

B-15 Ceiling IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 27 March 2016

MED 1150086

Page 27: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

27 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fabryka M ebli Okretowych FAM OS Sp z.o.o ...continued

Fire Resisting Lining Panel for Bulkhead – Type: “ B0/ B15-25” drawing No. TT/ PD-002 rev. A

B-15 Bulkhead IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 14 May 2016

USCG Module B

No: 164.108/ EC0

038 MED

1150141

Fire Resisting Ceiling – Type: “ Self-supporting Ceiling w ith fixtures” Drawing Nos. B-013-400 to 403

B-15 Ceiling IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 25 June 2016

USCG Module B

No: 164.110/ EC0

038/ MED

1150143

B-15 Class Fire Resisting Division, Bulkhead Panel System – Type: “ FAMOS Bulkhead B15 Class Promarine 450” Panel System

B-15 Bulkhead IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 4 December 2016

MED 1150317

Fire Resisting Acoustic Bulkhead – Type ‘’B0/ B15-25 Lining Wall’’

B-15 Bulkhead IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 17 March 2017

MED 1250020

Fire Resisting Acoustic Bulkhead – Type: “ B-15-50”

B-15 Bulkhead IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 24 April 2017

MED 1250021

Fire Resisting Ceiling Access Hatches according to the Drawing TT/ B-16-319

Ceiling Fixture IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 28 February 2017

MED 1250025

Page 28: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

28 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Bulkhead – Type: “ Acoustic Bulkhead B15-50”

B-15 Bulkhead IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 2 July 2017

MED 1250107

Fire Resisting Bulkhead Panel System – Type: “ B15-25 Lining Wall (Drawing No. B-22-005) ” w ith Sanitary Accessories

B-15 Bulkhead IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 and Annex 2 IMO MSC/ Circ.1120

Expires: 18 October 2017

MED 1250111 And

USCG Module B No:

164.108/ EC0038

Fire Resisting Ceiling – Type: “ Famos Self-Supporting B-0 Ceiling (Drawing No. S/ B-13-503)”

B-0 Ceiling IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 and Annex 2 IMO MSC/ Circ.1120

Expires: 18 October 2017

MED 1250112 And

USCG Module B No:

164.110/ EC0038

Page 29: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

29 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fabryka M ebli Okretowych FAM OS Sp z.o.o ...continued

Fire Resisting Ceiling Light Box – Type: “ Famos B-15 Ceiling w ith Fixture (Drawing Nos. B-22-001-B and B-22-001-A)”

B-15 Ceiling Fixture IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 and Annex 2 IMO MSC/ Circ.1120

Expires: 18 October 2017

MED 1250184

B-0 Ceiling Panel System – Type: “ FAMOS B-13-312”

B-0 Ceiling IMO Res. MSC.61(67) - IMO Fire Test Procedures Code, Annex 1, Part 3, MSC/ Circ.1120. IMO Res. MSC.307(88) – 2010 FTP Code, Section 8.

Expires: 27 July 2018

USCG Module B 164.110/ EC0038 MED 1350098

Fire Resisting Panel Ceiling – Type: “ Famos B15 ceiling TT/ SL-004”

B-15 CEILING IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 3 IMO MSC/ Circ. 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8 (Period of Grace)

Expires: 16 October 2018

MED 1350129

Fire Resisting Panel Bulkhead – Type “ B15-50”

B-15 BULKHEAD IMO Res.MSC.61(67)-(FTPCode), Annex 1 Part 3 IMO MSC/ Circ. 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8 (Period of Grace)

Expires: 3 December 2018

MED 1350136

Fire Resisting Panel Ceiling – Type “ Tile Ceiling B0”

B-0 Ceiling IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 3 IMO MSC/ Circ. 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8 (Period of Grace)

Expires: 3 December 2018

MED 1350137

Page 30: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

30 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Huanan Building M aterials (Shenzhen) Co., Ltd, 5th Floor Jiuzhou Electric Building, South District Hi-Tech Development Area, Shenzhen, 518057, China, People's Republic of.

Fire Resisting B-15 Class Bulkhead Panel System – Type: “ Marine B50M(III)”

B-15 BULKHEAD IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 3

Expires: 17 June 2019

MED 1450134

InterDam Holding B.V, Waaldijk 135, 2988 AW Ridderkerk, Netherlands, The.

Fire Resisting ‘B’ Class Ceiling – Type “ IDM B15/ A60 Ceiling”

B-15 CEILING IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 27 November 2019

MED 1450260/ M1

Page 31: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

31 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Japan Insulation Co. Ltd, Kinpai Building No. 3, 1-14-5 Shinkawa, Chuo-Ku, Tokyo, 104-0033, Japan.

Fire Resisting Bulkhead – Type: “ TAIKALITEMARINE B-15”

B-15 BULKHEAD IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 8 November 2015

MED 1050320

Jiangxi ChaoYang M achinery Plant, 993# Longcheng Road, Pengze County, Jiu Jiang City, Jiangxi Province, 332727, China, People's Republic of.

Fire Resisting Bulkhead Panel System – Type: “ B 50 A”

B-15 BULKHEAD IMO Res 61(67) – (FTP Code) Annex 1, Part 3. IMO MSC/ Circ.1120

Expires: 17 June 2017

MED 1250122/ M1

Fire Resisting Ceiling Panel System – Type: “ T 30 A(U)” with Light Fitting

B-0 CEILING IMO Res. 61(67) – (FTP Code) Annex 1, Part 3. IMO MSC/ Circ.1120

Expires: 17 June 2017

MED 1250123/ M1

Fire Retarding Bulkhead Panel System – Type: “ B50C”

B-15 Bulkhead IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 9 September 2012

MED 0850238 And USCG Module B 164.108/ EC0038

Fire Retarding Bulkhead Panel System – Type: “ B25C”

B-0 Bulkhead IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 9 September 2012

MED 0850239 And USCG Module B 164.108/ EC0038

Page 32: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

32 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting B-0 Class Bulkhead Panel – Type: “ B25A” Panel System

B-0 Bulkhead IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 15 April 2017

MED 1250143

Fire Resisting B-0 Class Ceiling Panel – Type: “ T25A” Panel System

B-0 Ceiling IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 15 April 2017

MED 1250144

Page 33: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

33 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Knauf B.V., M esonweg 8 - 12, 3542 AL Utrecht, Netherlands, The.

Fire Resisting Bulkhead Panel System – Type: “ Knauf Diamond Board DFH2IR 12,5AK”

B-15 Bulkhead IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 24 January 2013

MED 0850027/ M1 And USCG Module B number: 164.108/ EC0038

Liaoning Bohai Decorated-M aterial Co Ltd, Taishan Road, Beigang Industrial Area, Huludao, Liaoning Province, China, People's Republic of.

Fire Resisting Bulkhead Panel System – Type: “ BMC/ B-15/ 30C”

B-15 Bulkhead IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 14 February 2016

MED 1150069

M arine Systems Technology Ltd, Unit F, Nantwich Road, M iddlewich, Cheshire, CW10 0LH, United Kingdom (UK).

Fire Resisting Bulkhead Panel System– Type: “ COMFIRE HD 25” glass composite panel system (25mm thick)

B-15 BULKHEAD IMO Resolution MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 7 November 2016

MED 1150298

A-60 Equivalent Non Load Bearing Partition System - Type: “ Comfire C26 A60 Bulkhead” Bulkhead Panel System

NON LOAD BEARING PARTITION SYSTEM (STANDARD FIRE TEST)

IMO Res. MSC 307(88) - (2010 FTP Code) Annex 1 Part 3

Expires: 1 January 2019

MED 1450002

Page 34: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

34 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ercan Gemicilik San ve Tic A.S, Organize Deri Sanayi Bölgesi 7 Yol, F7 Parsel, Tuzla, Istanbul, Turkey.

Fire Resisting Bulkhead Panel System – Type: “ B-0 Lining Panel”

B-0 BULKHEAD IMO Res. MSC.61 (67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 14 February 2020

MED 1550119/ M1

Fire Resisting Ceiling Panel System – Type: “ B-0 Ceiling Panel”

B-0 Ceiling IMO Res. MSC.61 (67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 14 March 2020

MED 1550120/ M1

Fire Resisting Bulkhead Panel System – Type: “ B-15 Partition Panel”

B-15 BULKHEAD

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 14 February 2020

MED 1550121/ M1

Page 35: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

35 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Navantia U.P. Astillero San Fernando Puerto Real, Poligono Astillero, 11510 Puerto Real, Cadiz, Spain.

B-0 Class Fire Resisting Division, Ceiling Panel System – Type: “ Fixed Cabin Ceiling B-0”

B-0 CEILING IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 20 June 2021

MED 1650188

B-15 Class Fire Resisting Division, Ceiling Panel System – Type: “ Cabin Ceiling B-15”

B-15 CEILING IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 20 June 2021

MED 1650189

B-15 Class Fire Resisting Division, Bulkhead Panel System – Type: “ Cabin Panel B-15”

B-15 BULKHEAD IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 20 June 2021

MED 1650190

B-15 Class Fire Resisting Division, Bulkhead Panel System – Type: “ Cabin Panel (Double Panel System) B-15”

B-15 BULKHEAD IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 20 June 2021

MED 1650191

Oy Lautex Ab, P.O Box 58, FIN-03101 Nummela, Finland.

Fire Resisting Ceiling Panel System – Type: “ NST 300”

B-0 Ceiling IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 11 April 2016

MED 1150110

Fire Resisting Ceiling Panel System - Type: “ KST-150” and “ KST-200”

B-0 Ceiling IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 6 December 2016

MED 1150334

Page 36: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

36 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Division, B-0 Ceiling Panel System – Type: “ Self-supporting NBT-300” Panel System with fixtures

B-0 CEILING IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 9 March 2018

MED 1350006

B-0 Class Fire Resisting Division, Ceiling Panel System – Type: “ HT-300”

B-0 Ceiling IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 12 February 2018

USCG 164.110/ EC0038 MED 1350019

Page 37: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

37 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Oy Lautex Ab ...continued B-15 Class Fire Resisting Division, Ceiling Panel System – Type: “ NBT-300” Panel System

B-15 CEILING IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120 IMO Res. MSC 307(88) - (2010 FTP Code) Section 8

Expires: 12 March 2018

MED 1350030/ M1

Fire-Resisting Ceiling System – Type “ HT-300”

B-15 CEILING IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 31 December 2018

USCG Module B No: 164.110/ EC0038 MED 1450011

Fire Resisting Ceiling – Type: “ NLT-600”

B-0 CEILING IMO Res. MSC.61(67) – (FTP Code) - Annex 1, Part 3 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) – (2010 FTP Code) – Section 8.

Expires: 20 January 2019

MED 1450085

PANELSHIP, SLU, Poligono Industrial de A Lomba, Parroquia de Areas, Ponteareas, 36861, Ponteveda, Spain.

Fire Resisting Bulkhead Panel System– Type: “ Panel LC B-0”

B-0 Bulkhead IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 12 September 2017

MED 1250160

Fire Resisting Bulkhead Panel System– Type: ‘Panel PC B-15’

B-15 Bulkhead IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 12 September 2017

MED 1250161

Fire Resisting Division, Bulkhead Panel System – Type: “ Panel LC B15” Panel System

B15 Bulkhead IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 and Annex 2 IMO MSC/ Circ.1120

Expires: 1 October 2017

MED 1250188/ M1

Page 38: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

38 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

SBA Interior Ltd, Hallsnasintie 99, FIN-10360 M ustio, Finland.

Fire Resisting Ceiling – Type “ G Ceiling B0”

B-0 Ceiling IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 13 April 2015

MED 1050292

Fire Resisting Bulkhead Hatch - Type: “ JMC 1 INSPECTION DOOR 30 mm B-15”

B-15 Bulkhead Hatch IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 3, IMO MSC/ Circ. 1120

Expires: 16 January 2017

USCG Module B number:

164.108/ EC0038

MED 1250053

Page 39: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.11b 'A' AND 'B' CLASS DIVISION, FIRE INTEGRITY - 'B' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

39 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Unifrax Limited, M ill Lane, Rainford, St. Helens, M erseyside, WA11 8LP, United Kingdom (UK).

Fire Resisting ‘A’ Class Deck – Type: “ FyreWrap LT Blanket insulated Aluminium Bulkhead” for Restricted Applications w ith Insulation on Fire Exposed Side

A30 BULKHEAD IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 24 April 2018

MED 1350055

Wetcab Sp. z.o.o., ul. M arynarki Polskiej 59, Gdansk, 80-557, Poland.

Fire Resisting Ceiling – Type: “ Wetcab/ 400-2”

B-15 Ceiling IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) - (2010 FTP Code) Section 8

Expires: 25 August 2020

MED 1650106

Fire Resisting Bulkhead – Type: “ Wetcab B-15 Bulkhead”

B-15 Bulkhead IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) - (2010 FTP Code) Section 8

Expires: 10 November 2020

MED 1650107

Fire Resisting Bulkhead – Type: “ 50 B15 Class”

B-15 Bulkhead IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) - (2010 FTP Code) Section 8

Expires: 10 November 2020

MED 1650108

Page 40: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.12 DEVICES TO PREVENT THE PASSAGE OF FLAM E INTO THE CARGO TANKS IN TANKERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

40 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

ABS PV Endustriyel Valf Sanayi Ve Ticaret A.S., Aydinli M ahallesi, Evren Pasa Caddesi, G.81 Sokak, No.2 Aydinli Tuzla, Istanbul, Turkey.

High velocity venting valves: HNG-3/ 1926, HNG-4/ 1923, HNG-6/ 1951 Nominal diameters (mm) 80, 100 & 150

To relieve pressure ot vacuum and prevent the passage of flame into cargo tanks of oil and chemical tankers carrying products w ith a minimum MSEG of 0.65 mm

IMO/ MSC/ Circular 677; IMO/ MSC/ Circular 1009; IMO/ MSC.1/ Circular 1324; EN ISO 15364:2004 EN ISO 16852:2010

Expires: 17 February 2018 See Certificate for applicable conditions

MED 1300002/ M1

Flame Arrester, type ABS – 6/ 1952

Flame arrester, deflagration type, for gas/ air mixtures in explosion group IIA w ith an MESG of >0.9: Nominal diameter (mm): 150

IMO MSC/ Circ.677 IMO MSC/ Circ.1009 EN 12874:2001 ISO 15364:2007

Expires: 17 March 2020 Refer to certificate for conditions of approval

MED 1500003

Scanvent ApS, Solvang 16A, Allerod, DK-3450, Denmark.

High Velocity Valve Type: HVV-1, HVV-2, HVV-3, HVV-4, HVV-5 and HVV-7 Vacuum Valve Type: VV-1, VV-2 and VV-5, Gas-Freeing Cover Type: GF-85 & GF-200

End of line non oscillating high velocity P/ V Valves w ith integral gas-freeing cover, installed as a combined unit or separately for inerted tanks.

IMO MSC/ Circular 677 as amended by MSC Circ 1009 and MSC.1/ Circ.1324. EN ISO 12874:2001 ISO 15364:2007

Expires: 14 August 2016

MED 1100006/ M1

Page 41: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.13 NON-COM BUSTIBLE M ATERIALS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

41 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

ATIS International B.V., Noordhoek 33, 3351 LD Papendrecht, Netherlands, The.

Fire Resisting Material - Type: "Airisol Flex" and "Airisol Board" 24-78 kg/ m³

Non-Combustible Material IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 1 IMO Res. MSC.307(88) 2010 FTP Code, Section 8

Expires: 13 May 2018

MED 1350085/ M3

Fire Resisting Material – Type: “ Airisol board” (24 to 146 kg/ m3 density)

NON-COM BUSTIBLE M ATERIALS IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 1 IMO MSC/ Circ 1120 IMO Res. MSC.307 (88) - (2010 FTP Code) Section 8 (Period of Grace)

Expires: 26 January 2019

MED 1450052/ M1

Fire Resisting Material – Type: “ Caldic Monoglass” Insulation (Density 45 kg/ m3)

NON-COM BUSTIBLE M ATERIALS IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 1 IMO MSC/ Circ 1120 IMO Res. MSC.307 (88) - (2010 FTP Code) Section 8 (Period of Grace)

Expires: 9 December 2018

MED 1450054/ M1

British Gypsum, Head Office, East Leake, Loughborough, Leicestershire, LE12 6HX, United Kingdom (UK).

Fire-Resisting Material – Type “ “ Glasroc F Multiboard, Glasroc F Riflex, Glasroc F Stucal and Glasroc F Rinoflam”

NON-COM BUSTIBLE M ATERIAL IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 1 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8 IMO Res. MSC.307(88) – (2010 FTP Code) Part 1

Expires: 17 May 2019

MED 1450122

Dalian Huaxing Rock Wool Co Ltd, 22 Western Section, West Changchun Road, Wafangdian of Liaoning, China, People's Republic of.

Fire Resisting Material – Type “ DHXY-B150, DHXY-B60, DHXY-G150 and DHXY-G100’’ Mineral Wool.

NON-COMBUSTIBLE MATERIAL IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 1 IMO MSC/ Circ.1120

Expires: 2 August 2017

MED 1250140

Page 42: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.13 NON-COM BUSTIBLE M ATERIALS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

42 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Formglas Products Ltd, 2 Champagne Drive, Toronto, Ontario, M 3J 2C5, Canada.

Fire Resisting Material – Type: “ Formglas” (Density 1600 kg/ m3)

Non-Combustible Material IMO Fire Test Procedures Code, Annex 1, Part 1

Expires: 21 December 2018

MED 1450008

Fire Resisting Material – Type: “ Quarry Cast” (Density 1600 kg/ m3)

Non-Combustible Material IMO Fire Test Procedures Code, Annex 1, Part 1

Expires: 22 December 2018

MED 1450009

Helmers Accommodatie en Interieur BV, Vosholen 112, 9611 TG Sappemeer, Netherlands, The.

Fire-Resisting Material – Type “ Helmers Floor Anhydrite (HFA)”

NON-COM BUSTIBLE M ATERIAL IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 1

Expires: 6 November 2019

MED 1450241

Page 43: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.13 NON-COM BUSTIBLE M ATERIALS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

43 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Helmers Accommodatie en Interieur BV ...continued

Fire-Resisting Material – Type “ Helmers Floor Compound (HFC)”

NON-COM BUSTIBLE M ATERIAL IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 1

Expires: 6 November 2019

MED 1450243

Fire-Resisting Material – Type “ Helmers Levelling Compound (HLC)”

NON-COM BUSTIBLE M ATERIAL IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 1

Expires: 7 May 2020

MED 1550112

Hyundai Fiber Co. Ltd., #65 Sojugondan 4-gil, Yang San-Si, Kyungnam, 626-280, Korea, Republic of.

Fire-Resisting Material – Type “ E-glass Fiber Felt”

NON-COM BUSTIBLE M ATERIAL IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 1 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 23 August 2019

MED 1450254

Japan Insulation Co. Ltd, Kinpai Building No. 3, 1-14-5 Shinkawa, Chuo-Ku, Tokyo, 104-0033, Japan.

Fire Resisting Material – Type: “ TAIKALITEMARINE (Density 550kg/ m3)”

NON-COMBUSTIBLE MATERIAL IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 1 IMO MSC/ Circ.1120

Expires: 8 November 2015

MED 1050318

Fire-Resisting Material – Type “ TAIKALITEMARINE-AT” (density 550kg/ m³)

NON-COM BUSTIBLE M ATERIAL IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 1 IMO MSC/ Circ. 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8irc.1120

Expires: 8 November 2020

MED 1550283

Page 44: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.13 NON-COM BUSTIBLE M ATERIALS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

44 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jingjiang Dakeyuan New M aterials Engineering Co Ltd, No. 12 Xinsan Road, Chengbei Park, Economic Development Zone, Jingjiang City, Jingjiang Province, 214500, China, People's Republic of.

Fire-Resisting Material – Type “ DKY-6” Light Composite Fireproof Deck Covering

NON-COM BUSTIBLE M ATERIAL IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 1 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 21 January 2021

MED 1650040

Knauf d.o.o., Uzdolje polje 91, HR-22300 Knin, Croatia.

Fire-Resisting Material – Type “ Knauf Diamondboard Marine”

NON-COM BUSTIBLE M ATERIAL IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 1

Expires: 26 April 2020

MED 1550099

M arine Systems Technology Ltd, Unit F, Nantwich Road, M iddlewich, Cheshire, CW10 0LH, United Kingdom (UK).

Fire Resisting Material – Type: “ COMFIRE 440”

NON-COMBUSTIBLE MATERIAL IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 1 IMO MSC/ Circ.1120

Expires: 8 September 2015

MED 1050378

Page 45: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.13 NON-COM BUSTIBLE M ATERIALS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

45 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M organ Thermal Ceramics China, 18 Kang'an Road, Kangqiao Industrial Zone Pudong, Shanghai 201315, China, People's Republic of.

Non-combustible Material – Type: “ Kaowool FireMaster Blanket ” (Nominal density: 64 to 160 kg/ m3)

NON-COMBUSTIBLE MATERIAL IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 1 IMO MSC/ Circ.1120 IMO Res. MSC.307(88)-(2010FTP Code) Section 8

Expires: 7 February 2021

MED 1650064

Promat Techniczna Ochrona Przeciwpozarowa Sp. z.o.o., ul. Przeclawska 8, 03-879 Warszawa, Poland.

Fire Resisting Material – Type: “ PROMAGLAF HTI 1100”

NON-COM BUSTIBLE M ATERIAL

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 1

Expires: 2 March 2019

MED 1450048

Rockwool (India) Ltd, No. 21 & 22, Century Building, Rohini Layout, M adhapur, Hyderabad-500081, Telangana, India.

Fire Resisting Material – Type: “ ROCKINSUL Mattress” (75 to 150 kg/ m³ density)

NON-COM BUSTIBLE M ATERIAL IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 1 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 29 September 2020

MED 1550228/ M1

Fire Resisting Material – Type: “ ROCKINSUL Marine Slab” (75 to 150 kg/ m³ density)

NON-COM BUSTIBLE M ATERIAL IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 1 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 29 September 2020

MED 1550229/ M1

SM Tech Co Ltd, 556-15 Daeyeon-dong, Nam-gu, Busan, 608-810, Korea, Republic of.

Fire Resisting Material – Type: "SMT Fire Stop Sheet SMT-FX10" Density 1276 kg/ m3

NON-COMBUSTIBLE MATERIAL IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 1 IMO MSC/ Circ.1120

Expires: 29 April 2017

MED 1250076

Page 46: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.15c M ATERIALS OTHER THAN STEEL FOR PIPES CONVEYING OIL OR FUEL OIL - FLEXIBLE PIPE ASSEM BL

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

46 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Dunlop Oil & M arine Ltd, Jubilee Industrial Estate, Ashington, Northumberland, NE63 8UB, United Kingdom (UK).

Fireshield flexible hose assembly: Nominal diameter (inch): 1 Max. working pressure (bar): 165 Temperarture range (°C): –40 to +100

Short joining length of flexible hose to accommodate relative movement between machinery and fixed oil or fuel oil piping systems.

BS EN ISO 15540:1999; BS EN ISO 15541:1999

Expires: 9 July 2017 This approval relates to the fire resistance of the flexible hose assembly only. Additional testing may be required to comply with Classification Society Rules.

MED 1200007

Page 47: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

47 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

3 M aj Tibo d.d., Dalmatinskih Brigada 17, 51211 M atulji, Croatia.

Fire Resisting Single Leaf Hinged Door – Type: “ 3 MAJ TIBO A-30 Class Door Single Leaf Hinged”

A-30 Door Single Leaf Hinged IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 28 March 2016

MED 1150138 And

USCG Module B number:

164.136/ EC0038

Fire Resisting Single Leaf Hinged Door – Type: “ 3 MAJ TIBO A-60 Class Door Single Leaf Hinged”

A-60 Door Single Leaf Hinged IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 28 March 2016

USCG Module B number:

164.136/ EC0038

MED 1150139

Fire Resisting Single Leaf Hinged Door – Type: “ 3 MAJ TIBO B-15 Class Door Single Leaf Hinged”

B-15 Door Single Leaf Hinged IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 24 April 2016

USCG Module B number:

164.136/ EC0038

MED 1150140

Fire Resisting Inspection Hatch – Type ‘’B-0 Class Inspection Door’’

B-0 Bulkhead Hatch IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 13 February 2017

MED 1250074 And

USCG Module B number:

164.136/ EC0038

Bradgate Containers Ltd., Leicester Road, Shepshed, Leicestershire, LE12 9EG, United Kingdom (UK).

Fire Resisting Single Leaf Hinged Door – Type: “ Bradgate A-60 Door Single Leaf Hinged”

A-60 Door Single Leaf Hinged IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 27 February 2016

MED 1150123 And

USCG Module B number:

164.136/ EC0038

Page 48: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

48 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Cullum Detuners Ltd, Adams Close, Heanor Gate Industrial Park, Heanor, Derbyshire, DE75 7SW, United Kingdom (UK).

Fire Resisting Door – Type: “ Acoustic Enclosure Personnel Door”

A-0 Door Single Leaf Hinged IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 26 January 2020

MED 1550020

DONIM ET Spolka z ograniczona odpowiedzialnoscia Sp.K, 05-660 Warka, ul. Gosniewska 43, Poland.

Fire Resisting Single Leaf Hinged Door – Type “ DC3.1 A60 OR”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 7 September 2019

MED 1450186

Fire Resisting Single Leaf Sliding Door – Type “ DC SL A60 OR”

A-60 DOOR SINGLE LEAF SLIDING IMO Res. MSC.307(88) - (2010 FTP Code) Annex 1, Part 3 IMO MSC.1/ Circ.1319

Expires: 2 November 2020

MED 1550246

Page 49: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

49 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Elvik S.A., 12 Filellinon Street, Piraeus 185 36, Greece.

Fire Resisting Door – Type: “ B-15 Door” B-15 DOOR SINGLE LEAF HINGED IMO Resolution MSC. 61(67) - Fire Test Procedures Code, Annex 1, Part 3; IMO MSC/ Circ 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 2 March 2022

MED 1750036

Fabryka M ebli Okretowych FAM OS Sp z.o.o, ul Gdanska 37, 83-200 Starogard, Gdanski, Poland.

Fire Resisting Door – Type: “ B-15 Inspection Hatch”

B-15 Door Single Leaf Hinged IMO Res. MSC.61(67)-(FTP code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 18 March 2015

MED 1050066 And

USCG Module B number:

164.136/ EC0038

Fire Resisting Door – Type: “ FAMOS A-0/ A-30 Metal Fire Door With Hose Port”

A-30 Door Single Leaf Hinged IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 23 January 2015

MED 1050083

Fire Resisting Door – Type: “ Famos A60 Class to TT/ B-18-004 rev. C”

A-60 Door IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 10 August 2010

MED 0550252 And

USCG Module B number:

164.136/ EC0038

Fire Resisting Single Leaf Hinged Door – Types: “ FAMOS B-15 Class Acoustic Door”

B-15 Door Single Leaf Hinged

IMO Res. MSC 61.(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 15 January 2016 MED 1150054 And

USCG Module B number:

164.136/ EC0038

Page 50: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

50 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Single Leaf Hinged Door – Types: “ FAMOS A0-A30 Class Steel Ship Door ”

A-30 Door Single Leaf Hinged IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 28 February 2016

MED 1150057and

USCG Module B No.

164.136/ EC0038

Fire Resisting Door – Type: “ A-15 Class Metal Door to Drawing B-18-005”

A-15 Door Single Leaf Hinged IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 14 May 2016

USCG Module B number:

164.136/ EC0038

MED 1150142

Fire Resisting Door – Type ‘’A60 Single Leaf Hinged Door’’

A-60 Door Single Leaf Hinged IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 17 March 2017

MED 1250019

Page 51: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

51 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fabryka M ebli Okretowych FAM OS Sp z.o.o ...continued

Fire Retarding Door – Type: “ wg rys. WS/ P-130 002 zm. B”

B-15 Door Single Leaf Hinged IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 26 June 2017

MED 1250075 And USCG Module B number: 164.136/ EC0038

HGB GmbH, Steller Heide 23, 28790 Schwanewede, Germany.

Fire Resisting Single Leaf Hinged Door – Type: “ HGB Weathertight A60 Hinged Door”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 7 January 2021

MED 1650003

Fire Resisting Single Leaf Hinged Door- Type: "HGB Weathertight A60 Hinged Door"

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88)- (2010 FTP Code) Annex 1 Part 3

Expires: 16 November 2021

MED 1650276

Hollands M arine Lifts b.v., Rivierdijk 641b, 3371 EE Hardinxveld-Giessendam, Netherlands, The.

Fire Resisting Double Leaf Sliding Elevator Door – Type: “ A-30 Central Opening 2 Panel Lift Landing Door”

A-30 DOOR DOUBLE LEAF SLIDING

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 3

Expires: 9 February 2021

MED 1650070

Fire Resisting Double Leaf Sliding Elevator Door – Type: “ A-30 Central Opening 2 Panel Curved Lift Landing Door”

A-30 DOOR DOUBLE LEAF SLIDING IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 3

Expires: 9 February 2021

MED 1650071

InterDam Holding B.V, Waaldijk 135, 2988 AW Ridderkerk, Netherlands, The.

Fire Resisting Single Leaf Hinged Door – Type : “ IDM -SLH-A60-Int”

A-60 DOOR SINGLE LEAF HINGED IMO Res. 307(88) – (2010 FTP Code) Annex 1, Part 3 IMO MSC.1/ Circ.1319

Expires: 15 February 2021

MED 1650074

Page 52: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

52 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Door – Type: “ IDM-DLH-A60-XL Fire Door”

A-60 DOOR DOUBLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 22 December 2021

MED 1650296/ M1

Fire Resisting Door – Type: “ IDM-SLH-A60 Post Blast Fire Door

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 15 March 2022

MED 1750049/ M1

Jiangxi Chao Yang M achinery Plant, 993# Longcheng Road, Pengze Country, Jiu Jiang City, Jiangxi Province, 332727, China, People's Republic of.

Fire Resisting Double Leaf Hinged Door – Type: “ SMA60A”

A-60 DOOR DOUBLE LEAF HINGED IMO Resolution MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ. 1120 IMO MSC.1/ Circ. 1203

Expires: 29 June 2017

MED 1250240/ M1

Page 53: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

53 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jiangxi ChaoYang M achinery Plant, 993# Longcheng Road, Pengze County, Jiu Jiang City, Jiangxi Province, 332727, China, People's Republic of.

Fire Resisting Door – Type: “ MA60A-C with Glazed Panel”

A-60 Door Single Leaf Hinged IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 17 June 2017

MED 1250124/ M2

Fire Retarding Door - Type: “ NM B 15 A”

B-15 Door Single Leaf Hinged IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 17 June 2012

MED 0750129 And

USCG Module B number:

164.136/ EC0038

Fire Resisting Door – Type: “ MA15A” A-15 Door Single Leaf Hinged IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 9 September 2012

MED 0850237 And

USCG Module B number:

164.136/ EC0038

Jiangyin Huangshan M arine Fitting Co Ltd, No 28 Changshan Road, Chengjiang Street, Jiangyin City, 214400, China, People's Republic of.

Fire Resisting Deck Hatch – Type: 900x1200-8 (Drawing 263.16HS10-00)

A-0 DECK HATCH SINGLE LEAF HINGED

IMO Res. MSC.61 (67) Fire Test Procedures Code, Annex 1, Part 3, MSC/ Circ 1120

Expires: 2 June 2015

MED 1050129

Page 54: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

54 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Single Leaf Hinged Door – Type: “ A-60 Weathertight Steel Door w ith Porthole”

A-60 Door IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 17 August 2016

USCG Module B number:

164.136/ EC0038

MED 1150259

Fire Resisting Double Leaf Hinged Door – Type: “ A-60 Weathertight Steel Double Leaf Door”

A-60 Door IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 6 February 2010

MED 0550038 And

USCG Module B number:

164.136/ EC0038

Fire Resisting Single Leaf Hinged Door – Type: “ A-60 Weathertight Steel Door”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 17 August 2016

MED 1150312

Page 55: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

55 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Joiner Systems Technology Inc., 1925 52nd Avenue, Lachine, Quebec, H8T 3C3, Canada.

Fire Resisting Single Leaf Sliding Door – Type: “ D-013”

A-60 DOOR SINGLE LEAF SLIDING IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 3

Expires: 13 January 2019

MED 1450006

Fire Resisting Single Leaf Hinged Door – Type: “ D-005-2”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.61 (67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 6 October 2020

MED 1650067

Fire Resisting Single Leaf Hinged Door – Type: “ D-003-2”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 6 October 2020

MED 1650068

Fire Resisting Single Leaf Sliding Door – Type: “ D-108”

A-60 DOOR SINGLE LEAF SLIDING IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 14 September 2021

MED 1650221

Fire Resisting Door – Type: “ D-108” A-30 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 3 May 2022

MED 1750079

Liaoning Bohai Decorated-M aterial Co Ltd, Taishan Road, Beigang Industrial Area, Huludao, Liaoning Province, China, People's Republic of.

Fire Resisting Single Leaf Hinged Door – Type: “ MA60A”

A-60 Door IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 14 February 2016

MED 1150067

Page 56: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

56 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Single Leaf Hinged Door – Type: “ MB15-FT”

B-15 Door IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 14 February 2016

MED 1150068

M afo Holtkamp (Naval Closures) bv., Wierdensestraat 226, 7604 BS Almelo, Netherlands, The.

Fire Resisting Single Leaf Hinged Door – Type: “ MST A60 Comfire Plant on MAFO Fire Reistant Watertight Door System”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section

Expires: 27 January 2019

MED 1450138

M arine Interiors Spa, Via Genova 1, Trieste, 34121, I taly.

Fire Resisting Single Leaf Hinged Door – Type “ Marine Interiors MET 01-B15-VT”

B-15 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 2 November 2020

MED 1650198

Page 57: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

57 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M arine Systems Technology Ltd, Unit F, Nantwich Road, M iddlewich, Cheshire, CW10 0LH, United Kingdom (UK).

Fire Resisting Door – Type: “ A-30 SLH Door” with vision panel

A-30 DOOR SINGLE LEAF HINGED IMO Resolution MSC.307(88) - 2010 Fire Test Procedures Code, Annex 1, Part 3.

Expires: 13 March 2019

MED 1450057

Fire Resisting Single Leaf Hinged Door – Type: “ MST A0 Class Double Door with Vision Panel”

A-0 DOOR DOUBLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 1 June 2020

MED 1550137

M ercan Gemicilik San ve Tic A.S, Organize Deri Sanayi Bölgesi 7 Yol, F7 Parsel, Tuzla, Istanbul, Turkey.

B-15 SINGLE LEAF HINGED DOOR A.1/ 3.16 – FIRE DOORS 164.136 – FIRE DOORS

IMO Res. MSC.61 (67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 14 February 2020

MED 1550123/ M1

A-15 DOOR SINGLE LEAF HINGED

A.1/ 3-FIRE DOORS 164.136-FIRE DOORS

IMO Res. MSC.61 (67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 14 February 2020

MED 1550124/ M1

Fire Resisting Single Leaf Hinged Door – Type: “ A-60 Door”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.61 (67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 14 February 2020

MED 1550125/ M1

Page 58: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

58 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M etaldesi Srl, Via E Casoli 4, 60044 Fabriano (AN), I taly.

Fire Resisting Single Leaf Hinged Door – Type “ MET 00-B15-PVT TECHNICAL COMPARTMENT DOOR”

B-15 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 10 February 2020

MED 1550039

Fire Resisting Single Leaf Hinged Door – Type “ MET 00-B15-PEP Cabin Door”

B-15 DOOR SINGLE LEAF HINGED

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 18 October 2020

MED 1550239

Fire Resisting Single Leaf Hinged Door – Type “ MET 01-B15-VT”

B-15 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 21 November 2020

MED 1550262/ M2

Page 59: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

59 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M M L M arine Ltd, 60 Waverley Street, Coatbridge, North Lanarkshire, M L5 2BE, Scotland, United Kingdom (UK).

Fire Resisting Single Leaf Hinged Door – Type: “ MML A60 Single Leaf Door”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) 2010 FTP Code, Annex 1, Part 3

Expires: 14 August 2018

MED 1350113/ M3

Fire Resisting Single Leaf Hinged Door – Type: “ McGeoch A-60 Door with Vision Panel”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section

Expires: 31 August 2019

MED 1450201/ M2

B-15 DOOR SINGLE LEAF HINGED Fire Resisting Single Leaf Hinged Door – Type “ B-15 Door”

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 13 August 2019

MED 1450223/ M2

Fire Resisting Single Leaf Hinged Door – Type: “ A60 Double Leaf Hinged”

A-60 DOOR DOUBLE LEAF HINGED IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section

Expires: 31 October 2019

MED 1450235/ M2

Fire Resisting Single Leaf Hinged Door – Type: “ A-0/ A-15 Single Leaf Hinged Fire Door”

A-15 DOOR SINGLE LEAF HINGED IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) - (2010 FTP Code) Section 8

Expires: 31 October 2019

MED 1450246/ M2

Page 60: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

60 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Door – Type “B-15 Sliding Door”

B-15 DOOR SINGLE LEAF SLIDING IMO Res.MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Part 8

Expires: 25 May 2022

MED 1750071

NAVAL Suppliers s.r.l., Zona Industriale, 24, 33049 San Pietro Al Natisone, Udine, I taly.

Fire Resisting Door A-60 Door Double leaf Sliding IMO Fire Test Procedure Code, Annex 1, Part 3

Expires: 15 December 2010

MED 0550350/ M1

And USCG Module

B number: 164.136/ EC003

8

Page 61: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

61 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

NAVAL Suppliers s.r.l. ...continued

Fire Resisting Door- Type: “ B-15 Class Single Leaf Hinged Door w ith a Window”

B-15 Single Leaf Hinged Door With Window

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 3 February 2016

USCG Module B number:

164.136/ EC0038

MED 1150124

Fire Resisting Door-Type: “ A-15 Class Double Leaf Hinged Door”

A-15 Door Double Leaf Hinged IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 3 February 2016

USCG Module B number:

164.136/ EC0038

MED 1150125

Fire Retarding Door – Type: “ PORTA B-15 2 ANTE”

B-15 Door Double Leaf Hinged IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 3 February 2016

USCG Module B number:

164.136/ EC0038

MED 1150126

Fire Resisting Door – Type: “ B-15 Single Leaf Hinged Door with Ventilation Grille”

B-15 DOOR SINGLE LEAF HINGED IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ. 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8 (Period of Grace)

Expires: 4 September 2019

MED 1450182

Fire Resisting Double Leaf Hinged Glazed Door – Type: “ B-15 Double Glass Door”

B-15 DOOR DOUBLE LEAF HINGED IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ. 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8 (Period of Grace)

Expires: 4 September 2019

MED 1450183

Page 62: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

62 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

PANELSHIP, SLU, Poligono Industrial de A Lomba, Parroquia de Areas, Ponteareas, 36861, Ponteveda, Spain.

Fire Resisting Single Leaf Hinged Door– Type: ‘Panel D B-15’

B-15 Door IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 12 September 2017

MED 1250162

Fire Resisting Single Leaf Hinged Door– Type: ‘Panel D A-60’, w ith Vision Panel

A-60 Door Single leaf hinged IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 12 September 2017

MED 1250163

Fire Resisting Double Leaf Hinged Door– Type: ‘Panel DD A-60’, w ith Vision Panel

A-60 DOOR DOUBLE LEAF HINGED IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 12 September 2017

MED 1250164

Point Engineering (Hull) Ltd, Lee Smith Street, Hull, HU9 1SD, United Kingdom (UK).

Fire Resisting Door – Type: “ PEL-HSL-A60”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 3 May 2022

MED 1750080

Page 63: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

63 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Porkka Finland Oy, Huurretie 13, F133470 Ylöjärvi, Finland.

Fire Resisting Single Leaf Hinged Door – Type: “ HFD”

A-60 Door Single Leaf Hinged IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 3 and Annex 2 IMO MSC/ Circ 1120

Expires: 23 January 2016

USCG Module B number:

164.136/ EC0038

MED 1150042/ M1

Fire Resisting Door – Type: “ HFSD” Single Leaf Sliding Door

A-60 Door Single Leaf Sliding IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 3, IMO MSC/ Circ.1120

Expires: 11 February 2017

USCG Module B number:

164.136/ EC0038

MED 1250054

Fire Resisting Single Leaf Hinged Door – Type “ HFD”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) - (2010 FTP Code) Annex 1, Part 3 IMO MSC.1/ Circ.1319

Expires: 18 November 2020

MED 1550258

Stainless DownUnder NZ Ltd, 44 M arshall Road, Katikati 3178, New Zealand.

Fire Resisting Insulated Aluminium Door - Type: A-60 Weather Tight Fire Doors “ SDU-WFD-EA” and “ SDU-WFD-TA ”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC 307(88) - (2010 FTP Code) Annex 1 Part 3

Expires: 14 November 2018

MED 1350172

Fire Resisting Double Leaf Hinged Door – Type: “ SDU-WDFD”

A-60 DOOR DOUBLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 18 October 2020

MED 1550242/ M3

STRATHCLYDE M ARINE FABRICATIONS LTD, 11 Earn Avenue, Righead Industrial Estate, Bellshill, M L3 3LW, United Kingdom (UK).

Fire Resisting Single Leaf Hinged Door – Type: “ SD A-60-1000”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 3

Expires: 12 January 2019

MED 1450005

Page 64: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

64 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Single Leaf Hinged Door – Type: “ A60 Marine fire door with vision panel - SDVA60-1000”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 3

Expires: 20 July 2020

MED 1550190

Struik & Hamerslag B.V., Industriestraat 4, CC Strijen, NL-3291, Netherlands, The.

Fire Resisting Single Leaf Hinged Door – Type “ Struik & Hamerslag B15 Single Leaf Hinged Door”

B-15 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 24 July 2021

MED 1650250

Sturm GmbH, Niederland 155, 5091 Unken, Austria.

Fire Resisting Door – Type: “ SB-151-2” Double Leaf Hinged Door with Solid or Glazed Panels

Fire Resisting Door – Type: “ SB-151-2” Double Leaf Hinged Door with Solid or Glazed Panels

IMO Fire Test Procedures Code, Annex 1, Part 3 IMO MSC/ Circ.1120 IMO MSC.1/ Circ. 1273

Expires: 11 October 2017

MED 1250198

Page 65: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

65 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Sturm GmbH ...continued Fire Resisting Double Leaf Sliding Door – Type “ SB-155-2 ”

B-15 DOOR DOUB:E LEAF SLIDING IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO MSC.1/ Circ.1273 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 16 January 2021

MED 1650080

Fire Resisting Single Leaf Hinged Glazed Door – Type “ SB-151-1 Glazed Door”

B-15 Single Leaf Hinged Door IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO MSC/ Circ. 1273 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 16 January 2021

MED 1650081

Fire Resisting Single Leaf Sliding Door – Type: “ SB-155-1 w ith Glazed Panel”

B-15 SINGLE LEAF SLIDING DOOR IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 17 January 2021

MED 1650082

Fire Resisting Single Leaf Sliding Door – Type: “ SB-155-1 w ith Solid Panel”

B-15 SINGLE LEAF SLIDING DOOR IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 17 January 2021

MED 1650083

Fire Resisting Single Leaf Hinged Solid Door – Type: “ SB-151-1 Solid Door”

B-15 Single Leaf Hinged Door IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO MSC/ Circ. 1273 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 16 January 2021

MED 1650084

Page 66: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

66 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Sung M i Co Ltd, 1260 Naesam-Li, Joochon-M yun, Kimhae-Si, Gyeung Nam, Korea, Republic of.

Fire Resisting Double Leaf Hinged Door – Type: “ SM-A60-LD”

A-60 DOOR DOUBLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 17 December 2018

MED 1350171

T M Utley Offshore Plc, Silverdale House, Abbotsfield Road, St Helens, M erseyside, WA9 4HU, United Kingdom (UK).

Fire Resisting Single Leaf Hinged Door – Type: “ A-60 Single Leaf Hinged Fire Door” w ith Vision Panel

A-60 Single leaf Door IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 3, IMO MSC/ Circ.1120, MSC.1/ Circ.1273, MSC.1/ Circ.1319

Expires: 17 October 2016

MED 1150280

Page 67: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

67 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

T M Utley Offshore Plc ...continued

Fire Resisting Single Leaf Sliding Door – Type: “ A60 Single Leaf Sliding Fire Door”

A-60 DOOR SINGLE LEAF SLIDING IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 6 April 2021

MED 1650145

Fire Resisting Door – Type: “ A-60 Double Leaf Sliding Door”

A-60 DOOR DOUBLE LEAF SLIDING IMO Resolution MSC.61(67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO MSC.1/ Circ.1273 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 13 October 2021

MED 1650294

Tianchang Ocean Ship Equipment Co Ltd, No. 1880, Tianye Road, Tianchang, Anhui, 239300, China, People's Republic of.

Fire Resisting Single Leaf Hinged Door – Type “ A-0 YN”

A-0 DOOR SINGLE LEAF HINGED IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section

Expires: 16 March 2019

MED 1450135

Fire Resisting Single Leaf Hinged Door – Type: “ A-30 YN”

A-30 Door Single Leaf Hinged IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 16 March 2014

MED 0950086 And USCG 164.136/ EC0038

Fire Resisting Single Leaf Hinged Door – Type “ A-60 YN”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section

Expires: 16 March 2019

MED 1450137

Page 68: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

68 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

True Sea Services FZC, C1-11, Ajman Free Zone, United Arab Emirates (UAE).

Fire Resisting Single Leaf Hinged Door – Type: “ True Sea Services A15” Restricted Application

A-15 DOOR - SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 20 March 2021

MED 1650095

Van Dam B.V., Plaza 16, 4782 SK M OERDIJK, Netherlands, The.

Fire Resisting Single Leaf Hinged Door – Type: “ MEDAM 1”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 23 February 2020

MED 1550050

Fire Resisting Single Leaf Sliding Door – Type: “ GADAM 3”

A-60 DOOR SINGLE LEAF SLIDING IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120 IMO MSC.1/ Circ.1273

Expires: 10 March 2020

MED 1550078

Page 69: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.16 FIRE DOORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

69 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Van Dam B.V. ...continued Fire Resisting Single Leaf Hinged Door – Type: “ GADAM 1”

A-60 Door Single Leaf Hinged IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 10 March 2020

MED 1550080

Fire Resisting Single Leaf Hinged Door – Type: “ NADAM 4” Restricted to Applications With the Door Fully Locked at All Times.

A-60 DOOR SINGLE LEAF HINGED IMO Res. 307(88) - (2010 FTP Code) Annex 1, Part 3 IMO MSC.1/ Circ.1319

Expires: 8 April 2020

MED 1550081

Fire-Resisting ‘A’ Class Door – Type “ Van Dam Escape Hatch (A-60)”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 13 March 2022

MED 1750045

Van Dam BV, M arkweg zuid 1c, 4794 SN HEIJNINGEN, Netherlands, The.

Fire Resisting Double Leaf Hinged Door – Type: “ GADAM Type 2”

A-60 DOOR DOUBLE LEAF HINGED IMO Res. MSC.61(67)-(FTP code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 19 October 2018

MED 1350126/ M1

Page 70: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.17 FIRE DOOR CONTROL SYSTEM COM PONENTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

70 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

ADVANCED PNEUM ATIC M ARINE GM BH, Weddernkamp 6, 23858 Reinfeld, Germany.

Fire Resisting Fire Door Control System, Type: “ PCS 2000 AL Pneumatic Sliding Door Drive System”

Fire Door Control System IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 4 IMO MSC/ Circ.1120

Expires: 29 May 2017

MED 1250148/ M1

Fire Resisting Fire Door Control System – Type: “ ECS 2000 Electric Sliding Door Drive System”

Fire Door Control System IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 4 IMO MSC/ Circ.1120

Expires: 29 May 2017

MED 1250149

And USCG

Module B number:

164.146/ EC0038

Page 71: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

71 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

3M , 3M Center, Building 207-BW-09, St Paul, M N 55144-1000, United States of America (USA).

Fire Resisting Material - Type: “ 3M DI-NOC FW 887 “ decorative film

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 20 January 2016

MED 1150036

Fire Resisting Material - Type: “ 3M DI-NOC PS series “ decorative film

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 20 January 2016

MED 1150037

Fire Resisting Material - Type: “ 3M DI-NOC WG series “ decorative film

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 20 January 2016

MED 1150038

ATIS International B.V., Noordhoek 33, 3351 LD Papendrecht, Netherlands, The.

Fire Resisting Material - Type: "Airisol Fabric" bonded to glass wool or mineral wool boards/ blankets (glass wool density 16-78 kg/ m³, mineral wool density 41-200 kg/ m³)

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) 2010 FTP Code, Section 8

Expires: 13 May 2018

MED 1350082/ M3

Fire Resisting Material - Type: "Airisol Marine Cloth" bonded to glass wool or mineral wool boards/ blankets (glass wool density 16-78 kg/ m³, mineral wool density 41-200 kg/ m³)

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) 2010 FTP Code, Section 8

Expires: 13 May 2018

MED 1350083/ M3

Page 72: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

72 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material - Type: "Airisol Aluminium Foil (50 micron)" bonded to glass wool or mineral wool boards/ blankets (glass wool density 16-110 kg/ m³, mineral wool density 41-200 kg/ m³)

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) 2010 FTP Code, Section 8

Expires: 13 May 2018

MED 1350084/ M4

Fire Resisting Material – Type: “ Airisol Aluminium 20 micron grp reinforced fixed to a glass wool or rock wool board/ blankets” (glass wool density 18-78kg/ m3, rock wool density 32-200kg/ m3)

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXOC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88) - (2010 – FTP Code) Section 8

Expires: 7 June 2020

MED 1550212

Page 73: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

73 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

ATIS International B.V. ...continued

Fire Resisting Material – Type: “ Airisol/ CalRoc Profile insulation consisting of Airisol Marine Cloth, Airisol Aluminium 50 micron, Airisol Aluminium 20 micron grp reinforced or Airisol fabric, fixed to glass wool or rock wool board/ blankets” (glass wool density 18- 78kg/ m3, rock wool density 32-200kg/ m3)

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88) – (2010 FTP Code) Section 8

Expires: 7 June 2020

M ED 1550213

Dekodur GmbH & Co. KG, Langenthaler Straße 4, D-69434 Hirschhorn/Neckar, Germany.

Fire-Resisting Material – Type “ Dekoplus (Dekolor / Dekonova)”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res.MCS.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 28 November 2019

MED 1450258

Fire-Resisting Material – Type “ Dekorial HPL with metal laminate"

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 2 December 2020

MED 1550264

Den Braven Sealants BV, Postbus 194, 4900 AD Oosterhout, Denariusstraat 11, 4903 RC Oosterhaut, Netherlands, The.

Fire Resisting Material – Type “ Zwaluw Pyrocryl” (Nominal Thickness 8mm)

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 1 May 2017

MED 1250077

Fire Resisting Material – Type: “ Zwaluw Pyropol” (Nominal Thickess 8mm)

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 1 May 2017

MED 1250078

Page 74: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

74 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Dong M yung Ind. Co., 471-11, Bongam-dong, M asan Heowon-gu, Changwon, Kyungnam, 630-803, Korea, Republic of.

Fire Resisting Material - Type: “ DM-1433 Butyl Tape”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 21 November 2015

MED 1150218

Dong Sung Corporation, #807-1 Dukdori Kwangjukmyun Yangjushi, Kyongkido, Korea, Republic of.

Fire Resisting Material – Type: “ Interior deco sheet”

Materials Having Low Flame Spread Characteristics And Not Capable of Producing Excessive Quantities of Smoke And Toxic Products of Combustion

IMO Resolution MSC.61(67) – (FTP Code) Annex, 1, Part 5, and Annex 2 IMO MSC/ Circ.1120

Expires: 31 August 2015

MED 1050238 And USCG Module B No: 164.112/ EC0038

Page 75: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

75 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

EGGER KUNSTSTOFFE GmbH & Co. KG, Im Weilandmoor 2, D-38518 Gifhorn, Germany.

Fire Resisting Material - . Decorative Laminate Type: “ EGGER Schichtstoff (EGGER laminate)” (0.6mm and 0.8 mm thick) & “ EGGER Schichtstoff mit farbigem Kern (EGGER laminate coloured core)” (0.8 mm thick)

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Part 8 IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 23 September 2018

MED 1350124/ M2

Formglas Products Ltd, 2 Champagne Drive, Toronto, Ontario, M 3J 2C5, Canada.

Fire Resisting Material – Type: “ METALCAST”

Material Having Low Flame Spread Characteristics & Not Capable Of Producing Excessive Quantities Of Smoke & Toxic Production Of Combustion

IMO Fire Test Procedures Code, Annex 1, Part 5 and Part 2

Expires: 21 December 2018

MED 1450013

Formica Taiwan Corporation, 6th Floor, 68-70, Sec. 3 Nan King East Road, Taipei, Taiwan, 104, China, People's Republic of.

Fire Resisting Material – Type: “ Formica Decorative Laminate VGP 0.7mm Postfroming Grade”

Material Having Low Flame Spread Characteristics and not Capable of Producing Excessive Smoke & Toxic Products of Combustion

IMO Res. MSC 61(67) –(FTP Code) Annex 1, Part 5 and Part 2 IMO Msc/ Circ.1120

Expires: 3 January 2017

MED 1250119/ M1

Fritz Egger GmbH & Co. OG, Weiberndorf 20, A-6380 St. Johann in Tirol, Austria.

Fire-Resisting Material – Type: “ Egger Laminate XL” Decorative Laminate

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 7 April 2021

MED 1650116

Page 76: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

76 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Gage Corporation International, 803 S. Black River Street, Sparta, Wisconsin, 54656, United States of America (USA).

Fire Resisting Material – Type: “ Decorative Aluminium Ceiling Panel C20-65”

Material Having Low Flame Spread Characteristics and not Capable of Producing Excessive Quantities Smoke and Toxic Products of Combustion

IMO Resolution MSC.61(67) – Fire Test proceures Code, Annex 1, Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 26 June 2017

MED 1250115 And

USCG Module B number:

164.112/ EC0038

GENESIS YACHTLINE S.r.l., Via del Tiglio 121 (Loc. Sardina), Calcinaia PI , 56012, I taly.

Fire Resisting Material – Type: “ Wood FR” Real Wood Veneer (0.6mm thick)

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 5 and Part 2, IMO MSC/ Circ.1120 and ISO 1718 (2002).

Expires: 19 March 2017

MED 1250045

Page 77: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

77 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Guangzhou Weizhou M echanical and electrical Equipment Co,.Lt, Room 1112,Vanke Business centre, No.195,Shihua Road, Huangpu District, Guangzhou City, China, People's Republic of.

Fire Resisting Material: Type “ AF8701/ AF8702” Aluminium Foil Fiberglass Fabric Adhesive Tape

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 27 April 2021

MED 1650138/ M2

Guangzhou XingJian M arine Equipment Co., Ltd., No. 1 of 3, Qingluo Road, Shannan, Panyu, Guangzhou, China, People's Republic of.

Fire Resisting Material – Type: “ Aluminium Sheet Sandwich Panel”

M ATERIAL HAVING LOW FLAM E CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Resolution MSC.61(67) – (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 22 September 2020

MED 1550286

HOM APAL Plattenwerk GmbH & Co. KG, Bahnhofstrasse 30/32, 37412 Herzberg am Harz, Germany.

Fire Resisting Material – Type: “ HOMAPAL Metal Laminate”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67)-(FTP Code), Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8 (Period of Grace)

Expires: 4 March 2019

MED 1450096

Hylomar Ltd., Cale Lane, New Springs, Wigan, WN2 1JT, United Kingdom (UK).

Fire Resisting Material - Type "HYLOMAR SILICONE SEALANT 601"

Material Having Low Flame Spread Characteristics And Not Capable Of Producing Excessive Quantities Of Smoke And Toxic Products Of Combustion

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 19 July 2016

MED 1150237

Page 78: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

78 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Hyundai Fiber Co. Ltd., #65 Sojugondan 4-gil, Yang San-Si, Kyungnam, 626-280, Korea, Republic of.

Fire Retarding Material – Type: “ Aluminium Shielded Woven Fabric”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1, Part 2 and Part 5, and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) 2010 FTP Code, Section 8

Expires: 13 December 2020

MED 1650087

Leray Industrie (Shanghai) Co.,Ltd., Room 1141, Building 10,, East Yongchun Road No.10,, Datuan Town, Pudong Area,, Shanghai, 200123, China, People's Republic of.

Fire Resisting Material: Type “ EEL-AGC” Aluminium Foil Fiberglass Fabric Self-Adhesive Tape

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code), Annex 1, Part 5 and Annex 2.

Expires: 14 December 2020

MED 1550284

Page 79: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

79 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Leray Industrie (Shanghai) Co.,Ltd. ...continued

Fire Resisting Material:Type “ EEL-FST” Aluminium Foil Fibreglass Scrim Self-Adhesive Tape

M ATERIAL HAVING LOW FLAM E SPREAD–CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code), Annex 1, Part 5 and Annex 2

Expires: 14 December 2020

MED 1550285

LG Hausys, 388 M angyang-ri, Onyang-eup, Ulju-gun, Ulsan City, 689-901, Korea, Republic of.

Fire Resisting Material – Type: “ LG Hausys Interior Film” Self Adhesive PVC Film (0.23mm thick)

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 30 December 2017

MED 1250256

Fire Resisting Material - Type: “ LG Nutrex PVC 0.18 mm”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 5 and Part 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88)-(201 FTP Code) Section 8

Expires: 25 January 2021

MED 1650150

LG Hausys Ltd, Surface M aterials Division Strategy Team, One IFC 18F, 10 Gookjegeumyoong_Ro,, Yeongdeungpo_Gu,, Seoul, 150-876, Korea, Republic of.

Fire Resisting Material - Type: “ HI-MACS FR SOLID” Decorative Covering Product Nos S705, S706, S728, S729, S801

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 9 December 2018

MED 1450003

Page 80: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

80 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ajilite Corporation, 1530 Broadway Road, Dracut, M assachusetts 01826 - 2830, United States of America (USA).

Fire Resisting Bulkhead Finish Material – Type: “ Novasuede IMO 653”

Material Having Low Flame Spread Characteristics and Not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 20 December 2016

MED 1150328

Fire Resisting Bulkhead Finish Material – Type: “ WP Wall Covering”

Material Having Low Flame Spread Characteristics and Not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 20 December 2016

MED 1150329

M anifattura A Testori di G SpA, Via Dante 7, 20026 Novate M ilanese (M ilano), I taly.

Fire Resisting Material – Type: “ ART.8200 – Wall & Panel Covering”

Material Having Low Flame Spread Characteristics And Not Capable Of Producing Excessive Quantities Of Smoke And Toxic Products Of Combustion

IMO Res. MSC.61 (67)-(FTP Code) Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120.

Expires: 14 February 2016

MED 1150062 And

USCG Module B number:

164.112/ EC0038

Page 81: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

81 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M CM TEC Co. Ltd, 100-1, Kum San-Ri, Wae Kwan-Eup, Chilock-Kun, Kyung-Buk, 718-800, Korea, Republic of.

Fire Resisting Material – Type: “ Multi Color Printed Steel Sheet”

Material Having Low Flame Spread Characteristics and not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 18 July 2015

MED 1050324

Fire Resisting Material – Type: “ Multi Color Printed Aluminium Sheet”

Material Having Low Flame Spread Characteristics and not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 18 July 2015

MED 1050325

M erima Oy, Tatti 10, 00760 Helsinki, Finland.

Fire Resisting Material – “ Merima Board, FAO.02” fabric covered aluminium sheet.

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Resolution MSC.61(67) – (FTP Code) Annex, 1, Part 5, and Annex 2 IMO MSC/ Circ.1120 IMO Resolution MSC.61(67) – 2010 FTP Code – Section 8

Expires: 25 March 2019

MED 1450105

Nature Squared, Zürcherstrasse 170, 8645 Jona, Switzerland.

Fire Resisting Material – Type: “ Nature Squared Eggshell Inlays Nature Squared Sea Shell Inlays”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 21 June 2021

MED 1650155

Fire Resisting Material – Type: “ Nature Squared Tree and Plant Inlays”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 5 June 2021

MED 1650156

Page 82: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

82 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material – Type: “ Decorative surfaces w ith metal or paint effects”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 13 March 2022

MED 1750046

NEWM AT SAS, 22 rue du Général Dame, B.P.141, 59482 HAUBOURDIN, Cedex, France.

Fire Resisting Material – Type: “ PVC Stretch Ceiling” Flexible Thin Film Membrane

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88)-(2010 FTP Code) Annex 1, Part 5 and Annex 2

Expires: 7 March 2022

MED 1750041

Page 83: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

83 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

NORM ALU SAS, Route du Sipes, 68680 Kembs, France.

Fire Resisting Material – Type: “ Toile Barrisol 25/ 100 and Toile Barrisol 18/ 100” Ceiling membrane plastic film

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1 Part 5, and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 30 September 2020

MED 1650093

Panolam Industries International, 20 Progress Drive, Shelton, CT 06484, United States of America (USA).

Fire Resisting Material – “ Pionite Type K 32”

Material having low flame spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Resolution MSC.61(67) – (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 1 November 2015

MED 1050361 And

USCG Module B No:

164.112/ EC0038

Fire Resisting Material – “ Pionite Type K 51”

Material having low flame spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Resolution MSC.61(67) – (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 1 November 2015

MED 1050362 And

USCG Module B number:

164.112/ EC0038

Fire Resisting Material – “ Pionite Type K 61”

Fire resisting material having low flame spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Resolution MSC.61(67) – (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 1 November 2015

MED 1050363 And

USCG Module B number:

164.112/ EC0038

Page 84: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

84 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

REPLASA, Autovia Pamlona-Logrono, A12 - Salida 9, Astrain ( Navarra ),, 31190, Spain.

Fire Resisting Material - Type: “ DECORPLATE” PVC covered aluminium or steel sheet

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Resolution MSC.61(67) – (FTP Code) Annex, 1, Part 5, and Annex 2 IMO MSC/ Circ.1120 IMO Resolution MSC.61(67) – 2010 FTP Code – Section 8

Expires: 17 March 2019

MED 1450062

REPLASA, Autovia A12 - Salida 9, Astrain (Navarra), 31190, Spain.

Fire-Resisting Material – Type “ INOXPLATE-STARPLATE” Adhesive Film

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 14 September 2019

MED 1450261

Rockwool Limited, Pencoed, Bridgend, Wales, CF35 6NY, United Kingdom (UK).

Fire Resisting Material – Type: “ C BOARD” , “ C LINER” - Slab, Pipe Section, Wired Mat and Roll” (45-200kg/ m3 density) with a Glass Cloth facing (weight 455g/ m2)

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 5 and Annex 2. IMO MSC/ Circ.1120

Expires: 16 February 2015

MED 1050042

Page 85: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

85 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Roxul Asia Sdn Bhd., 175 A & B, Kawasan Perindustrian Air Keroh, Jalan Lingkungan Usaha, 75450 M elaka, M alaysia.

Fire Resisting Material - Type: “ Glass Cloth Covering Conlit-150P 756”

Material having low flame spread chararcteristics & not capable of producing ecessive quantities of smoke and toxic porducts

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 1 June 2016

MED 1150154

Fire Resisting Material - Type: “ Aluminium Foil Covering Conlit-150U 756”

Material having low flame spread characteristics and not capable of producing excessive quantities of smoke and toxic products of combustion

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 1 June 2016

MED 1150155

Shemara Refit LLP, Ocean Quay, Belvedere Road, Southampton, SO14 5QY, United Kingdom (UK).

Fire Resisting Material – Type: “ Tuning Film Carbon BF” Self-Adhesive PVC Film

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 5 and Annex 2.

Expires: 27 June 2021

MED 1650167

SM Tech Co Ltd, 556-15 Daeyeon-dong, Nam-gu, Busan, 608-810, Korea, Republic of.

Fire Resisting Material – Type: “ Fibre Glass Laminating Butyl Tape”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 5 and Annex2 IMO MSC/ Circ.1120

Expires: 19 March 2017

MED 1250044

Fire Resisting Material – Type: “ SMT Fire Delay Sheet” Flexible Fabric

Material having low flame spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 ISO 1716:2002

Expires: 30 January 2018

USCG Module B number:

164.112/ EC0038

MED 1350049

Page 86: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

86 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Specialist Services, P.O. Box 2752, Dubai, United Arab Emirates (UAE).

Fire Resisting Material – Type: “ Fire Retardant GRP Laminate”

Material having low flame spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 15 August 2015

USCG Module B number:

164.112/ EC0038

MED 1050260

Stork Lijmen, Lepelaar 23, NL-3881 DD Leusden, Netherlands, The.

Fire Resisting Material - Type: “ Aquence KL 072/ 6” Adhesive

Material Having Low Flame Spread Characteristics & Not Capable Of Producing Excessive Quantities Of Smoke & Toxic Products Of Combustion

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 15 January 2018

USCG Module B No:

164.112/ EC0038

MED 1350090

Stretch Ceilings Ltd, Doman Road, Yorktown Industrial Estate, Camberley, Surrey, GU15 3DF, United Kingdom (UK).

Fire Resisting Material – Type: “ Stretch Ceiling Membrane” (0.2mm thick, 200g/ m2 weight)

Material Having Low Flame Spread Characteristics And Not Capable Of Producing Excessive Smoke And Toxic Products Of Combustion

IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 7 March 2017

MED 1250031

Page 87: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

87 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Tarkett Polska Spó?ka z Ograniczon? Odpowiedzia, Oddzial w Jasle, UL M ickiewicza 108, 38-200 Jaslo, Poland, 38-200, Poland.

Fire Resisting Floor Covering Material – Type: “ Specjal 43 Plus”

A.1/ 3.18 SURFACE MATERIALS AND FLOOR COVERINGS WITH LOW FLAME- SPREAD CHARACTERISTICS (C) FLOOR COVERINGS

IMO Res. MSC.307 (88) - (2010 FTP Code), Annex 1, Part 5 and Part 2

Expires: 30 November 2021

MED 1650284

Venture Tape Corporation, 30 Commerce Road, Rockland, M A 02370, United States of America (USA).

Fire Resisting Material – Type “ 1524CW” self adhesive tape

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 11 April 2015

MED 1050081

Fire Resisting Material – Type “ 1577CW-Tedlar” self adhesive foil tape

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 11 April 2015

MED 1050082

Vescom B.V., St. Jozefstraat 20, 5753 AV Deurne, Netherlands, The.

Fire-Resisting Material – Type “ Vescom Fabric Backed Vinyl Wallcovering”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8 IMO Res. MSC.307(88) – (2010 FTP Code) Part 2 and Part 5

Expires: 30 April 2019

MED 1450101

Page 88: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

88 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire-Resisting Material – Type “ Vescom Silk Wallcovering”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ. 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 1 March 2022

MED 1750034/ M1

Whiting Door M fg Corp, 113 Cedar St,, Akron, N.Y. 14001, United States of America (USA).

Low Flame Spread Material – Type ‘’CJ0000-000’’

MATERIALS HAVING LOW FLAME-SPREAD CHARACTERISTICS – SURFACES AND FLOOR

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 5 IMO MSC/ Circ.1120

Expires: 12 March 2017

MED 1250035

Low Flame Spread Material – Type ‘’CJ0003-004’’

MATERIALS HAVING LOW FLAME-SPREAD CHARACTERISTICS – SURFACES AND FLOOR

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 5 IMO MSC/ Circ.1120

Expires: 12 March 2017

MED 1250036

Page 89: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18a SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - DECORATIVE V

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

89 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Y. Canning Co., 31-46 Sungyui 4-dong, Nam-Ku, Incheon-City, 402-812, Korea, Republic of.

Fire Resisting Material - Type: “ RTV Silicone Sealant 601“ Adhesive

Material having low flame spread characteristics & not capable of producing excessive quantities of smoke &toxic products of combustion

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 26 January 2016

MED 1150137

Page 90: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

90 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

BBM G Energy Saving M aterial & Technology Company, Gaojing #2, Chaoyang District, Beijing, 100123, China, People's Republic of.

Fire Resisting Material: Type “ CY insulation with surface material”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code), Annex 1, Part 5 and Annex 2

Expires: 2 December 2020

MED 1550263/ M1

Dalian M ingyang Deck Covering Co., Ltd., No. 468-8, Shuangdao Wan Road, Lvshunkou, Dalian, China, People's Republic of.

Fire-Resisting Material – Type “ Guanzhou EP-100”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 2 and Part 5

Expires: 2 July 2019

MED 1450157/ M1

Fabryka M ebli Okretowych FAM OS Sp z.o.o, ul Gdanska 37, 83-200 Starogard, Gdanski, Poland.

Fire Resisting Material - Type: “ Freilacke PP 1002 A“ Powder Paint Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2, IMO MSC/ Circ 1120, ISO 1716:2002

Expires: 30 August 2016

MED 1150251

Fire Resisting Material - Type: “ IGP Dura face 5803“ Powder Paint Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2, IMO MSC/ Circ 1120, ISO 1716:2002

Expires: 30 August 2016

MED 1150252

Page 91: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

91 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Helder & M ay B.V., M oezelweg 202, 3198 LS Rotterdam-Europoort, Netherlands, The.

Fire-Resisting Material – Type “ NAUTEC FS 09” Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 20 August 2020

MED 1550217/ M1

Fire Resisting Material – Type: “ Nautec LFX”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 3 May 2022

MED 1750078

Hempel Korea Co. Ltd., 5. Jobang-ro, 16 beon-gil, Dong-gu, Busan 601-711, Korea, Republic of.

Fire-Resisting Material – Type “ Hempel HB Primer K150 with Hempalin Enamel HB 52220 Topcoat”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 2 and Part 5

Expires: 4 March 2019

MED 1450100

Page 92: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

92 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Hempel Korea Co. Ltd. ...continued

Fire Resisting Material – Type: “ Hempel HB Primer K150 with Hempel Rostico B/ D Topcoat 52390”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. 307(88) - (2010 FTP Code) Annex 1, Part 2, Part 5 and Annex 2

Expires: 4 March 2019

MED 1450190

International Paint Ltd, Stoneygate Lane, Felling, Gateshead, Tyne & Wear, NE10 0JY, United Kingdom (UK).

Fire Resisting Material - Type: “ Intergard 343/ Intergard 162 / Intercryl 700 / Intercryl 700“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 26 August 2015

MED 1050231

Fire Resisting Material - Type: “ Intergard 8600 / Intergard 8600“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Annex 2 IMO MSC/ Circ 1120

Expires: 6 September 2015

MED 1050243

Fire Resisting Material – Type: “ Interprime 538” and “ Interlac 665”

Material having Low Flame Spread Characteristics and not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res. MSC.61 (67)-(FTP code) Annex 1 Part 2 and Part 5. IMO MSC/ Circ.1120.

Expires: 18 January 2016

USCG Module number:

164.112/ EC0038

MED 1150018

Fire Resisting Material - Type:- “ Inorganic Zinc Primer + Interbond 201” paint scheme

Material having low flame spread characteristics and not capable of producing excessive smoke and toxic products of combustion.

IMO Res. MSC.61 (67)-(FTP code) Annex 1 Part 2 and Part 5. IMO MSC/ Circ.1120.

Expires: 18 January 2016

USCG Module B number:

164.112/ EC0038

MED 1150026

Page 93: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

93 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material – Type: “ Interline 974” Coating

Material Having Low Flame Spread Characteristics and not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res. MSC.61 (67)-(FTP code) Annex 1 Part 2 and Part 5. IMO MSC/ Circ.1120.

Expires: 18 January 2016

USCG Module B number:

164.112/ EC0038

MED 1150027

Fire Resisting Material – Type: “ Intergard 343”

Material having Low Flame Spread Characteristics and not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res. MSC.61 (67)-(FTP code) Annex 1 Part 2 and Part 5. IMO MSC/ Circ.1120.

Expires: 18 January 2016 USCG Module B number:

164.112/ EC0038

MED 1150028

Fire Resisting Material – Type: “ Intergard 343/ Intercryl 700” Paint System

material having low flame spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 25 January 2016

MED 1150058

Page 94: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

94 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material - Type: “ Intergard 276 / Interlac 665“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 28 March 2016

MED 1150100

Fire Resisting Material - Type: “ Intergard 787/ Intergard 5555“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 19 April 2016

MED 1150120

Fire Resisting Material - Type: “ Intergard 5500“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 19 April 2016

MED 1150121

Fire Resisting Material - Type: “ Intergard 5505WB“ Paint System

Material having low flame spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 19 April 2016

MED 1150122 & USCG Module B Number: 164.112/ EC0038

Fire Resisting Material - Type: “ Intergard 269 / Intershield 259 / Interthane 990 / Interthane 990 / Intershield 609 / Colour Chips / Intershield 609“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 22 May 2016

MED 1150149

Page 95: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

95 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material – Type: “ Intergard 403”

Material Having Low Flame Spread Characteristics and Not Capable of Producing Excessive Quantities of Smoke & Toxic Products of Combustion

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 11 July 2016

MED 1150185

Fire Resisting Material – Type: “ Intergard 423”

Material Having Low Flame Spread Characteristics and Not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 11 July 2016

MED 1150186

Fire Resisting Material – Type: “ Intergard 5620”

Material Having Low Flame Spread Characteristics and Not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 11 July 2016

MED 1150187

Page 96: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

96 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material - Type: “ Intergard 400 / Intergard 740” Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 11 July 2016

MED 1150188

Fire Resisting Material - Type: “ Intergard 7343 / Intergard 740“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 4 July 2016

MED 1150191

Fire Resisting Material - Type: “ Intergard 7343 / Interthane 989“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 4 July 2016

MED 1150192

Fire Resisting Material - Type: “ Intergard 7343 / Interthane 990“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 4 July 2016

MED 1150193

Fire Resisting Material - Type: “ Intergard 7343 / Intergard 7343“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 4 July 2016

MED 1150194

Page 97: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

97 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material - Type: “ Intergard 7343 / Intergard 410” Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 4 July 2016

MED 1150195

Fire Resisting Material - Type: “ Zinc primer / Interlac 5786 / Interlac 5786“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 10 August 2016

MED 1150221/ M1

Page 98: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

98 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material - Type: “ Interprime 198 NB / Interlac 665” Paint System

Material Having Low Flame Spread Characteristics and not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 11 July 2016

MED 1150223

Fire Resisting Material – Type: “ Intergard 361/ Interlac 665”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

Fire Resisting Material - Type: “ Intergard 361 / Interlac 665“ Paint System

Expires: 26 July 2016

MED 1150224

Fire Resisting Material - Type: “ “ Zinc primer / Intergard 269 / Intershield 300HS / Intergard 162 / Interthane 990 “ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 22 August 2016

MED 1150238

Fire Resisting Material - Type: “ Zinc primer / Intergard 5000 / Intersheen 5579 / Intersheen 5579“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 24 August 2016

MED 1150239/ M1

Fire Resisting Material - Type: “ Interprime 198 / Interprime 198 / Interlac 665 / Interlac 665 “ Paint System

Material Having Low Flame Spread Characteristics and not Capable of Producing Excessive Smoke and Toxic Products of Combustion

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 31 October 2016

MED 1150276

Page 99: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

99 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material - Type: “ “ Zinc Primer / Interprime 5538 / Interprime 5538 / Intersheen 5579 / Intersheen 5579” Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 2 November 2016

MED 1150295/ M1

Fire Resisting Material – Type: “ Intergard 269, Interseal 670HS, Interthane 990” Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61(67) - (FTP Code) Annex 1, Part 5 and Part 2 IMO MSC/ Circ.1120

Expires: 3 September 2017

MED 1250158

Fire Resisting Material - Type: “ Interline 925“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 5 September 2017

MED 1250159

Page 100: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

100 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material - Type: “ Intergard 7500 / Interlac 6700“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 17 October 2017

MED 1250199

Fire Resisting Material - Type: “ Interplate 937 / Intergard 7600 / Intergard 410 / Intergard 410“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC 307(88) - (2010 FTP Code) Annex 1 Part 2 and Part 5

Expires: 11 February 2018

MED 1350012

Fire Resisting Material - Type: “ Interior Primer 860“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8 (Period of Grace)

Expires: 10 February 2018

MED 1350014/ M1

Fire Resisting Material - Type: “ Interior Primer 860 - Interior Finish 750 (RAL9010 YE657/ 11-15)“ or “ Interior Primer 860 - Interior Finish 750 (YE657/ 6-10)“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8 (Period of Grace)

Expires: 10 February 2018

MED 1350015/ M2

Fire Resisting Material - Type: “ Interior Primer 860 – Awlgrip Topcoat (YE657/ 21-25)’ Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8 (Period of Grace)

Expires: 17 February 2018

MED 1350023/ M1

Page 101: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

101 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material – Type: “ Interplate 837HS”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC 307(88) – (2010 FTP Code) Annex 1, Part 5 and Annex 2

Expires: 18 March 2018

MED 1350037

Fire Resisting Material – Type: “ Intershield 300/ Interlac 6700” Paint System

Material Having Low Flame Spread Characteristics & Not Capable Of Producing Excessive Quantities Of Smoke & Toxic Products Of Combustion - Paint Ssytems

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 30 April 2018

USCG Module B No:

164.112/ EC0038

MED 1350051

Fire Resisting Material – Type: “ Interplate 837/ Interlac 6700” Paint System

Material Having Low Flame Spread Characteristics & Not Capable Of Producing Excessive Quantities Of Smoke & Toxic Products Of Combustion - Paint Sysytems

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 30 April 2018

USCG Module B No:

164.112/ EC0038

MED 1350052

Page 102: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

102 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material - Type: “ Interior Primer 330WB’ Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 2 October 2018

MED 1350130

Fire Resisting Material - Type: “ Interior Primer 330WB / Interior Finish 600WB’ Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 2 October 2018

MED 1350133

Fire Resisting Material - Type: “ lntergard 361/ lntergard 740HS” Two Coat Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 12 December 2018

MED 1350165

Fire Resisting Material - Type: “ lntershield 300HS/ lntergard 740HS” Two Coat Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 12 December 2018

MED 1350166

Fire Resisting Material - Type: “ lntershield 300/ lntergard 740HS” Two Coat Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 12 December 2018

MED 1350167

Page 103: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

103 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material - Type: “ Intergard 787/ lntergard 740HS” Two Coat Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 12 December 2018

MED 1350168

Fire Resisting Material - Type: “ Intergard 400/ lntergard 740HS” Two Coat Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 12 December 2018

MED 1350169

Page 104: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

104 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material - Type: “ Intergard 7500/ lntergard 740HS” Two Coat Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 12 December 2018

MED 1350170

Fire Resisting Material – Type: “ Interstores Epoxy Primer-Finish/ Interstores Polyurethane Topcoat” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – 2010 Fire Test Procedures Code, Annex 1, Part 5 and Part 2

Expires: 5 March 2019

MED 1450049

Fire Resisting Material – Type: “ Interprime 198/ Interstores Alkyd Topcoat” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – 2010 Fire Test Procedures Code, Annex 1, Part 5 and Part 2

Expires: 5 March 2019

MED 1450050

Fire-Resisting Material – Type “ Intergard 361 / Intergard 740” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 22 February 2019

MED 1450058/ M2

Fire-Resisting Material – Type “ Intergard 343 / Interlac 6700” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 22 February 2019

MED 1450059/ M2

Page 105: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

105 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire-Resisting Material – Type “ Intergard 400 / Interthane 990” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 22 February 2019

MED 1450060

Fire-Resisting Material – Type “ Intergard 361 / Interthane 990” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 22 February 2019

MED 1450063/ M2

Page 106: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

106 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material – Type: “ Wash Primer CF/ Interior Finish 750” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – 2010 Fire Test Procedures Code, Annex 1, Part 5 and Part 2

Expires: 14 April 2019

MED 1450081

Fire Resisting Material, Type: “ Interprime 198” coating system.

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Annex 1, Part 5 and Annex 2.

Expires: 6 April 2019

MED 1450086

Fire Resisting Material - Type: “ Intertherm 50” coating system.

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Annex 1, Part 5 and Annex 2.

Expires: 6 April 2019

MED 1450087

Fire Resisting Material, Type:- “ Interprime 198 Primer with Interlac 665 Finish” .

Material having Low Flame Spread Characteristics and not Capable of Producing Excessive Smoke and Toxic Products of Combustion

IMO Fire Test Procedures Code Annex 1, Part 5 and Annex 2.

Expires: 16 February 2009

MED 0450077

Fire Resisting Material – Type: “ Intergard 7600/ Intergard 7600” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Part 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 7 April 2019

MED 1450090

Page 107: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

107 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material – Type: “ Intergard 7600/ Interthane 990” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 7 April 2019

MED 1450091

Fire Resisting Material – Type: “ Intergard 7600/ Intergard 410” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 7 April 2019

MED 1450092

Fire Resisting Material – Type: “ Intergard 7600/ Intergard 740” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 7 April 2019

MED 1450093

Page 108: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

108 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire-Resisting Material – Type “ Intergard 5620 / Interthane 990” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 8 June 2019

MED 1450099

Fire-Resisting Material – Type “ Intergard 5600 / Interthane 990” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 8 June 2019

MED 1450103

Fire-Resisting Material – Type “ Intergard 5620 / Intergard 410” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 8 June 2019

MED 1450107

Fire-Resisting Material – Type “ Intergard 5600 / Intergard 410” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 8 June 2019

MED 1450108

Fire-Resisting Material – Type “ Intergard 5620 / Intergard 740” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 8 June 2019

MED 1450109

Fire-Resisting Material – Type “ Intergard 5600 / Intergard 740” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 8 June 2019

MED 1450110

Page 109: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

109 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire-Resisting Material – Type “ Wash Primer CF / Awlgrip Topcoat” Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 5 and Annex 2

Expires: 13 May 2019

MED 1450112

Fire-Resisting Material – Type “ Intershield 300” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 27 July 2019

MED 1450162/ M1

Page 110: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

110 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire-Resisting Material – Type “ Intershield 300 / Interthane 990” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 27 July 2019

MED 1450163/ M1

Fire-Resisting Material – Type “ Interlac 786” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 15 November 2019

MED 1450202/ M1

Fire-Resisting Material – Type “ Interior Primer 860 / Interior Finish 750 Satin Black” Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 2 and Part 5

Expires: 5 October 2019

MED 1450203

Fire-Resisting Material – Type “ Intergard 410/ Interlac 665 ” Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 5 and Annex 2

Expires: 8 April 2020

MED 1550079/ M1

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

Fire-Resisting Material – Type “ Intergard 269 / Interbond 201 / Intergard 740” Paint Coating System

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 19 April 2020

MED 1550090/ M1

Fire-Resisting Material – Type “ Intertuf 262 / Intertuf 262 / Interlac 665 / Interlac 665” Paint Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 24 April 2020

MED 1550091/ M1

Page 111: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

111 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd, Stoneygate Lane, Felling, Gateshead, Tyne & Wear, NE10 0JY, United Kingdom (UK).1550091

Page 112: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

112 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire-Resisting Material – Type “ Intershield 300 / Intershield 300” Paint Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 24 April 2020

MED 1550092/ M1

Fire-Resisting Material – Type “ Intergard 269 / Interbond 201” Paint Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 24 April 2020

MED 1550093

Fire-Resisting Material – Type “ Intergard 269 / Interprime 538 / Interlac 665 / Interlac 665” Paint Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 24 April 2020

MED 1550094/ M1

Fire-Resisting Material – Type “ Intergard 5555” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 28 April 2020

MED 1550102/ M2

Fire-Resisting Material – Type “ Intershield 300 / Intergard 5505WB ” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 2 and Part 5

Expires: 28 April 2020

MED 1550116

Fire-Resisting Material – Type “ Intergard 7500 / Intergard 5505WB ” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 2 and Part 5

Expires: 28 April 2020

MED 1550117

Page 113: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

113 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

Fire Resisting Material – Type: “ Interzone 954” Coating System

IMO Fire Test Procedures Code, Annex 1, Part 5 and Part 2 IMO Res. MSC.307(88)-(2010 FTP Code) Section 8

Expires: 3 June 2020

MED 1550138

Fire Resisting Material - Type: “ Intergard 787/ Intergard 5555“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 26 August 2020

MED 1550167

Page 114: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

114 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material - Type: “ Intergard 269/ Intergard 5600 / Interbond 201“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 26 August 2020

MED 1550168

Fire Resisting Material - Type: “ Intergard 269/ Intergard 5620 / Intergard 162 / Interlac 665 / Interlac 665“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 26 August 2020

MED 1550169

Fire Resisting Material - Type: “ Intergard 269/ Intergard 5620 / Intergard 162 / Interthane 990 / Interthane 990“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 26 August 2020

MED 1550170

Fire Resisting Material - Type: “ Intergard 269/ Intergard 5620 / Interbond 201“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 26 August 2020

MED 1550171

Fire Resisting Material - Type: “ Intergard 269/ Intergard 7600 / Intergard 162 / Interlac 665 / Interlac 665“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 26 August 2020

MED 1550172

Page 115: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

115 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material - Type: “ Intergard 269/ Intergard 7600 / Intergard 162 / Interthane 990 / Interthane 990“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 26 August 2020

MED 1550173

FFire Resisting Material - Type: “ Intergard 269/ Intergard 7600 / Interbond 201“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 26 August 2020

MED 1550174

Page 116: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

116 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material – Type: “ Inorganic Zinc Primer + Interprime 538 + Interlac 542” Paint Scheme

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 12 October 2020

MED 1550175

Fire Resisting Material – Type: “ Inorganic Zinc Primer + Interprime 538 + Interlac 665” Paint Scheme

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTIC & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 5 and Annex 2

Expires: 12 October 2020

MED 1550176

Fire Resisting Material - Type: “ Interior Primer 860/ Interior Finish 600WB” Coating System (Ref.YI1/ 37/ 19-23)

Material Having Low Flame Spread Characteristics & Not Capable Of Producing Excessive Quantities Of Smoke & Toxic Products Of Combustion

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part5, and Annex 2 IMO MSC/ Circ.1120

Expires: 4 August 2020

MED 1550182

Fire Resisting Material - Type: “ Intergard 269/ Intergard 5600 / Intergard 162 / Interlac 665 / Interlac 665“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 26 August 2020

MED 1550192

Fire Resisting Material - Type: “ Interplate Zero / Intergard 269 / Intershield 300 / Intergard 162 / Interthane 990 / Interthane 990 “ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 6 September 2020

MED 1550193

Page 117: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

117 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material – Type: “ Intergard 162/ Interthane 990”

M ATERIAL HAVING LOW FLAM E CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2. IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 12 October 2020

MED 1550194

Fire Resisting Material – Type: “ Intergard 276/ Interlac 786”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res.MSC 307(88) - 2010 Fire Test Procedures Code, Annex 1, Part 5 and Annex 2

Expires: 6 August 2020

MED 1550198

Fire Resisting Material – Type: “ Intergard 276/ Interthane 990/ Interthane 990”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res.MSC 307(88) - 2010 Fire Test Procedures Code, Annex 1, Part 5 and Annex 2

Expires: 6 August 2020

MED 1550199

Page 118: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

118 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material – Type: “ Inorganic zinc shop primer/ Intershield 300/ Interthane 990/ Interthane 990”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res.MSC 307(88) - 2010 Fire Test Procedures Code, Annex 1, Part 5 and Part 2

Expires: 6 August 2020

MED 1550200

Fire Resisting Material - Type: “ Intergard 787/ Intergard 787“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 6 September 2020

MED 1550209/ M1

Fire Resisting Material - Type: “ Intergard 787/ Interlac 6700“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 26 August 2020

MED 1550210/ M1

Fire Resisting Material - Type: “ Intergard 787/ Intergard 740“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 26 August 2020

MED 1550211/ M1

Fire-Resisting Material – Type “ Interplate 837” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 18 January 2021

MED 1550249/ M1

Page 119: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

119 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire-Resisting Material – Type “ Interzone 1000” Floor Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 2 and Part 5

Expires: 18 November 2020

MED 1550259

Fire-Resisting Material – Type “ Primer/ Intergard 400/ Interlac 665” Paint Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 18 January 2021

MED 1550277

Fire Resisting Material – Type: “ Interior Primer 860/ Interior Insulation TMC (DFT 1146 microns)” Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 17 December 2020

MED 1550287

Page 120: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

120 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material – Type: “ Interior Primer 860/ Interior Insulation TMC (DFT 2400 microns)” Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 17 December 2020

MED 1550288

Fire Resisting Material – Type: “ Intergard 5000/ Interior Insulation TMC/ Interfine 878” Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 17 December 2020

MED 1550289

Fire Resisting Material – Type: “ Inorganic Zinc Primer + Interbond 201” Paint Scheme

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88) - (2010 FTP Code), Annex 1 Part 2 and Part 5.

Expires: 18 January 2021

MED 1650011/ M1

Fire Resisting Material – Type: “ Intergard 269”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS AND NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE AND TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5. IMO MSC/ Circ.1120. IMO Res. MSC.307 (88) - (2010 FTP Code), Section 8.3

Expires: 18 January 2021

MED 1650012

Fire Resisting Material – Type: “ Intertuf 262” Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS AND NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE AND TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code Annex 1 Part 2 and Part 5. IMO MSC/ Circ.1120. IMO Res. MSC.307 (88) - (2010 FTP Code), Section 8.3

Expires: 18 January 2021

MED 1650013

Page 121: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

121 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material - Type: “ Intershield 300HS / Intershield 300HS“ Paint System

M ATERIAL HAVING LOW FLAM E SPEAD CHARECTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5. IMO MSC/ Circ.1120. IMO Res. MSC.307 (88) - (2010 FTP Code), Section 8.3

Expires: 18 January 2021

MED 1650014

Fire Resisting Material - Type: “ Intershield 300HS / Interthane 990 / Interthane 990“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5. IMO MSC/ Circ.1120. IMO Res. MSC.307 (88) - (2010 FTP Code), Section 8.3

Expires: 18 January 2021

MED 1650015

Fire Resisting Material - Type: “ Zinc primer / Intergard 269 / Intershield 300HS / Interfine 979 / Interfine 878“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120 IMO Res. MSC.307 (88) - (2010 FTP Code), Section 8.3

Expires: 24 January 2021

MED 1650016

Page 122: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

122 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material - Type: “ Zinc primer / Intergard 269 / Intershield 300HS / Interthane 990“ Paint System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS AND NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 & Part 5 IMO MSC/ Circ 1120 IMO Res. MSC.307 (88) - (2010 FTP Code), Section 8.3

Expires: 25 January 2021

MED 1650017

Fire-Resisting Material – Type “ Intergard 7600 / Interlac 789 ” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 7 February 2021

MED 1650065/ M1

Fire-Resisting Material – Type “ Intergard 7600 / Interthane 870 ” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 7 February 2021

MED 1650066/ M1

Fire Resisting Material – Type: “ Intergard 269/ Interior Primer 860/ Interior Finish 770” Paint Scheme

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 23 March 2021

MED 1650103

Fire Resisting Material – Type: “ Interior Primer 860/ 545/ Awlcraft 2000” Paint Scheme

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 23 March 2021

MED 1650104

Page 123: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

123 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material – Type: “ Interline 644 / Interline 644” Paint Scheme

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 23 March 2021

MED 1650105

Fire Resisting Material – Type: “ Intergard 5500” Paint Scheme.

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 5 and Annex 2.2.

Expires: 10 July 2021

MED 1650180

Fire Resisting Material – Type: “ Interprime 198NB / Interlac 665” Paint Scheme.

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 5 and Annex 2.2.

Expires: 10 July 2021

MED 1650181

Page 124: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

124 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire-Resisting Material – Type “ Intergard 400 / Intergard 740 ” Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 14 August 2021

MED 1650210/ M1

Fire-Resisting Material – Type “ Intergard 403 ” Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 21 August 2021

MED 1650211/ M1

Fire-Resisting Material – Type “ Intergard 423 ” Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 21 August 2021

MED 1650212/ M1

Fire-Resisting Material – Type “ Intergard 5260 ” Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 21 August 2021

MED 1650213/ M3

Fire-Resisting Material – Type “ Interstores Alkyd Primer / Interlac 665” Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 2 and Part 5

Expires: 30 August 2021

MED 1650217/ M1

Fire-Resisting Material – Type “ Interstores Alkyd Primer / Interstores Alkyd Primer ” Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 5 and Annex 2

Expires: 30 August 2021

MED 1650218/ M1

Page 125: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

125 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material – Type: “ Interprime 198 / Interprime 198 / Interlac 665 / Interlac 665” Paint Scheme

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 16 September 2021

MED 1650226

Page 126: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

126 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire-Resisting Material – Type “ Intergard 269 / Interprime 538 / Interprime 538 / Interlac 665 / Interlac 665 ” Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 2 and Part 5

Expires: 23 September 2021

MED 1650231

Fire-Resisting Material – Type: “ Interzinc 52 / Intergard 475HS / Interthane 990” Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ. 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 13 December 2021

MED 1650233

Fire-Resisting Material – Type: “ Intergard 7500 / Intergard 7500” Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ. 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 13 December 2021

MED 1650234

Fire-Resisting Material – Type: “ Intergard 7500 / Intergard 740” Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ. 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 13 December 2021

MED 1650235

Fire-Resisting Material – Type: “ Intergard 7500 / Interlac 665 ” Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ. 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 13 December 2021

MED 1650236

Fire-Resisting Material – Type: “ Interzinc 22 ” Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ. 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 13 December 2021

MED 1650237

Page 127: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

127 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material – Type: “ InterH20 499/ Intercryl 700” Coating System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 5 March 2022

MED 1650295

Page 128: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

128 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Fire Resisting Material – Type: “ Intershield 300, Intershield 300, Interfine 979 and Interfine 878” Coating System

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res.MSC.61(67)-(FTP Code) Annex 1, Part 5 and Part 2. IMO MSC/ Circ.1120 IMO Res. MSC.307(88) - 2010 Fire Test Procedures Code, Section 8.

Expires: 20 February 2022

MED 1750009

Jingjiang Dakeyuan New M aterials Engineering Co Ltd, No. 12 Xinsan Road, Chengbei Park, Economic Development Zone, Jingjiang City, Jingjiang Province, 214500, China, People's Republic of.

Fire-Resisting Material – Type “ DKY-1” Light Primary Deck Covering

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 21 January 2021

MED 1650035

Fire-Resisting Material – Type “ DKY-2” Super Light Primary Deck Covering

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 21 January 2021

MED 1650036

Fire-Resisting Material – Type “ DKY-5” Flat Deck Covering

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 21 January 2021

MED 1650039

Page 129: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

129 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

JP Coatings GmbH, Im Kreuz 6, D-97076 Würzburg, Germany.

Fire Resisting Material - Type: “ 2K Marinecolor 952 w ith Marine Hardener 910“ Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Annex 2 IMO MSC/ Circ 1120

Expires: 14 September 2015

MED 1050252

KCC Corporation, Ulsan Plant, 30 Bangeojinsunhwan-doro, Dong-gu, Ulsan, Korea, Republic of.

Fire Resisting Material – Type: “ Komaster EH4200” Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61(67)-(FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 31 October 2017

MED 1250221

Fire Resisting Material – Type: “ Korepox H.B. EH4600” Paint System

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61(67)-(FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 31 October 2017

MED 1250222

Page 130: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18b SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PAINT SYSTEM

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

130 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M etawell GmbH, metal sandwich technology, Schleifmühlweg 31, D-86633 Neuburg/Donau, Germany.

Fire Resisting Material - Types: “ Metawell Flex, Metawell Single Panel, Metawell Double Panel”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC 307(88) - (2010 FTP Code) Annex 1 Part 2 and 5 and Annex 2 and Section 8

Expires: 13 January 2019

MED 1450007/ M2

NoFire Technologies Inc., 21 Industrial Avenue, Upper Saddle River, New Jersey 07458, United States of America (USA).

Fire Resisting Material – Type: “ NoFire A-18” Fire Retardant Intumescent Paint (500 microns nominal thickness)

Material Having Low Flame Spread Characteristics and Not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 16 May 2016

MED 1150066 And USCG Module B Number: 164.112/ EC0038

Oy Lautex Ab, P.O Box 58, FIN-03101 Nummela, Finland.

Fire Resisting Material - Type: “ Lautex Marine Metal Ceiling”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 21 February 2015

MED 1050098/ M2

REPLASA, Autovia Pamlona-Logrono, A12 - Salida 9, Astrain ( Navarra ),, 31190, Spain.

Fire Resisting Material – Type: “ COLORPLATE” polyurethane coating on galvanised steel sheet

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 5 and Part 2. MSC/ Circ. 1120. IMO Res. MSC.307(88) – 2010 Fire Test Procedures Code, Section 8.

Expires: 4 July 2018

MED 1350091

The Amtico Company Limited, Kingfield Road, Coventry, West M idlands, CV6 5AA, United Kingdom (UK).

Fire-Resisting Material – Type “ Amtico Marine (01-14)”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 & 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8 IMO Res. MSC.307(88) – (2010 FTP Code) Part 2 and Part 5

Expires: 1 May 2019

MED 1450102/ M4

Page 131: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18c SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - FLOOR COVERI

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

131 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

"GAM RAT" Spólka Akcyjna, 38-200 Jaslo, ul. M ickiewicza 108, Poland.

Fire Resisting Material - Type: “ Specjal 43 Type S “ Floor Covering

Material having low flame spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 12 June 2016

MED 1150261 And

USCG Module B No:

164.117/ EC0038

Fire Resisting Material – Type: “ Specjal 43 type Plus” Sheet Floor Covering

Material having low flame spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 12 June 2016

MED 1150262 And

USCG Module B number:

164.117/ EC0038

Fire Resisting Floor Coverings-Types: “ Centra 43” and “ Norma 43” Pressed Floor Coverings

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code), Annex 1, Part 5 and Annex 2.

Expires: 22 August 2018

MED 1350114

Alarwool S.L., Calle Vitoria No. 15, 2 Piso, 09004 Burgos, Spain.

Fire Resisting Material – Type: “ Alarwool Axminster carpet”

Material Having Low Flame Spread Characteristics And Not Capable of Producing Excessive Quantities of Smoke And Toxic Products of Combustion

IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 5 and Part 2 IMO MSC/ Circ.1120 IMO Res.MSC.307 (88) - (2010 FTP Code) Section 8.

Expires: 23 September 2021

MED 1650278

Altro Ltd, Works Road, Letchworth Garden City, Herts, SG6 1NW, United Kingdom (UK).

Fire Resisting Material - Type: “ MAR20001 – MAR20999 Gallium” Floor Covering

Material Having Low Flame Spread Characteristics and not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 9 May 2016

MED 1150197

Page 132: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18c SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - FLOOR COVERI

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

132 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material - Type: “ Altro Transflor Momentum Safety Floor Covering, 2mm thick (MOM2001 – MOM20999) and 2.5mm thick (MOM2501 – MOM25999)”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 24 August 2017

MED 1250152

Ardex UK Limited, Homefield Road, Haverhill, Suffolk, CB9 8QP, United Kingdom (UK).

Fire Resisting Material - Type: “ ARDEX AF 100” Pressure sensitive acrylic adhesive.

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67)-(FTP Code) Annex 1 Part 5 and Part 2. IMO MSC/ Circ.1120

Expires: 3 May 2015

MED 1050100

Fire Resisting Material - Type: “ ARDEX AF 150” Adhesive For Floor Coverings

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67)-(FTP Code) Annex 1 Part 5 and Part 2. IMO MSC/ Circ.1120

Expires: 3 May 2015

MED 1050101

Page 133: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18c SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - FLOOR COVERI

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

133 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Ardex UK Limited ...continued

Fire Resisting Material - Type: “ ARDEX X 77 S” Cement based Tile adhesive.

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67)-(FTP Code) Annex 1 Part 5 and Annex 2. IMO MSC/ Circ.1120

Expires: 3 May 2015

MED 1050102

Bentley Prince Street, 14641 E. Don Julian Rd, City of Industry, CA 91746, United States of America (USA).

Fire Resisting Carpet – Type: “ Base Metal”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 28 May 2017

MED 1250097

Fire Resisting Carpet – Type: “ Tufted Yarn Dyed Loop Nylon 6.6”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 28 May 2017

MED 1250098/ M1

Fire Resisting Carpet – Type: “ Palace Court 28”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 28 May 2017

MED 1250099

Fire Resisting Carpet – Type: “ Palace Court 24”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 28 May 2017

MED 1250100

Page 134: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18c SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - FLOOR COVERI

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

134 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Bostik Ltd, Ulverscroft Road, Leicester, LE4 6BW, United Kingdom (UK).

Fire Resisting Material - Type: “ L73 MULTICRYL” Floor Covering Adhesive

Material Having Low Flame Spread Characteristics & Not Capable Of Producing Excessive Quantities Of Smoke & Toxic Products Of Combustion

IMO Resolution MSC.61(67) – (FTP Code) Annex, 1, Part 2 and Part 5, and Annex 2 IMO MSC/ Circ.1120

Expires: 24 January 2015

MED 1050024 And USCG Module B No: 164.117/ EC0038

Fire Resisting Material - Type: “ Screedmaster 2 Ultimate” Floor Covering Smoothing Compound

Material Having Low Flame Spread Characteristics & Not Capable Of Producing Excessive Quantities Of Smoke & Toxic Products Of Combustion

IMO Resolution MSC.61(67) – (FTP Code) Annex, 1, Part 2 and Part 5, and Annex 2 IMO MSC/ Circ.1120

Expires: 24 January 2015

MED 1050025 And USCG Module B No: 164.117/ EC0038

Page 135: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18c SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - FLOOR COVERI

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

135 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Bostik Ltd ...continued Fire Resisting Material - Type: “ Laybond CV” Synthetic Resin Emulsion Flooring Adhesive (3506.9100)

Material having low flame spread characteristics and not capable of producing excessive smoke and toxic products of combustion.

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 13 March 2015

MED 1050094 And

USCG Module B No:

164.112/ EC0038

Fire Resisting Material - Type: “ Laybond Multibond Gold” Multi-purpose Acrylic Flooring Adhesive (3506.9900)

Material having low flame spread characteristics and not capable of producing excessive smoke and toxic products of combustion

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ. 1120

Expires: 13 March 2015

MED 1050095

Fire Resisting Material – Type: “ Laybond Quickstrip Underlay”

Material having low flame-spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 5 and Part 2 IMO MSC/ Circ.1120

Expires: 3 August 2015

MED 1050201

Changzhou Around Global Carpet M anufacture Co., Ltd, 91, North of ChenDu Town, Hua Yuan, ChangZhou, JiangSu, 213016, China, People's Republic of.

Fire Resisting Material – Type: “ Axminster Carpet AGC/ AX8020”

Material having low flame spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Resolution MSC.61(67) – (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 25 May 2016

MED 1150070 And

USCG Module B number:

164.117/ EC0038

Desso B.V., Taxandriaweg 15, 5142 PA Waalwijk, Netherlands, The.

Fire Resisting Material – Type: “ Aero 750” Carpet

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS AND NOT CAPABLE OF PRODUCING EXCESSIVE SMOKE AND TOXIC PRODUCTS OF COMBUSTION

IMO Fire Test Procedures Code, Annex 1, Part 5 and Part 2 IMO MSC/ Circ 1120.

Expires: 24 January 2015

MED 1050022 And USCG Module B N: 164.117/ EC0038

Page 136: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18c SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - FLOOR COVERI

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

136 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material – Type: “ Group Gravure 1100-1400” of Tufted Cut Pile Carpets (range of weights 2500g/ m2 to 2800g/ m2)

Materials having low flame spread characteristics & not capable of producing excessive quantities of smoke & toxic products of combustion

IMO Res.MCS.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 21 March 2018

MED 1350041

Fire Resisting Material – Type: “ Colortec 1200, 1400, 1500 and 1650 Carpets” (range of weights 2460 g/ m2 to 3300g/ m2)

Material Having Low Flame Spread Characteristics and not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res.MCS.61(67)-(FTP Code) Annex 1 Part 2 and Part 5, and Annex 2, IMO MSC/ Circ.1120

Expires: 1 September 2019

MED 1450172

Fire Resisting Carpet – Type: “ Symphony Carpet 1100 – 1400”

Material having Low Flame Spread Characteristics and not Capable of Producing Excessive Quantities of Smoke and Toxic Products of Combustion

IMO Res.MSC.61(67)-(FTP Code) Annex 1, Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 1 September 2019

MED 1450174

Page 137: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18c SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - FLOOR COVERI

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

137 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Desso B.V. ...continued Fire Resisting Material – Type: “ Décor B and Axminster A La Carte” woven cutpile carpet (Range of total weights: 1800 to 2750 g/ m2)

Material Having Low Flame Spread Characteristics And Not Capable of Producing Excessive Smoke And Toxic Products of Combustion

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 1 September 2019

MED 0950332/ M2

H.I Korea Co. Ltd, 749-5 Jang Rok-Dong, Gwangsan-Gu, Gwangju, 506-507, Korea, Republic of.

Fire Resisting Material – Type: “ HIFLEX-HET” EPDM Rubber Foam Insulation (Tape)

Material having low flame spread characteristics and not capable of producing excessive quantities of smoke and toxic products of combustion

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 4 April 2016

MED 1150103

Fire resisting material – Type: “ HIFLEX-NHE” EPDM Rubber Foam Insulation (Sheet)

Material having low flame spread characteristics and not capable of producing excessive amounts of smoke and toxic products of combustion

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 4 April 2016

MED 1150104

International Paint Ltd, Stoneygate Lane, Felling, Gateshead, Tyne & Wear, NE10 0JY, United Kingdom (UK).

Fire Resisting Flooring Material – Type “ Interzone 1000”

Material Having Low Flame Spread Characteristics And Not Capable Of Producing Excessive Quantities Of Smoke And Toxic Products Of Combustion

IMO Res. MSC.61 (67)-(FTP code) Annex 1 Part 2 and Part 5. IMO MSC/ Circ.1120.

Expires: 18 January 2016

USCG Module B number:

164.112/ EC0038

MED 1150024

Kasra Chem Ltd, 352 Nuneaton Street, Glasgow, G40 3JU, United Kingdom (UK).

Floor Covering - Type: “ KC-Flor 310SC-M”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120

Expires: 30 March 2016

MED 1150101

Page 138: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18c SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - FLOOR COVERI

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

138 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Leggett & Platt, 969 Corporate Blvd, Aurora, I llinois 60502, United States of America (USA).

Fire-Resisting Material – Type “ Padlock Maritime Carpet Support and Nautical One” ”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 26 October 2019

MED 1450225

Nature Squared, Zürcherstrasse 170, 8645 Jona, Switzerland.

Fire Resisting Material – Type: “ Woven Products”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 13 March 2022

MED 1750047

Recticel B.V., Schuilheuvelstraat 1, 4116 GA Buren, Netherlands, The.

Fire-Resisting Material – Type “ Fenixbase” Carpet Underlay

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 20 October 2018

MED 1350135/ M1

Page 139: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18c SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - FLOOR COVERI

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

139 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Recticel B.V. ...continued Fire Resisting Material – Type: “ Recticel IMO” Carpet Underlay

A.1/ 3.18 - Surface Materials & Floor Coverings With Low Flame-Spread Characteristics – Floor Coverings

IMO Fire Test Procedures Code, Annex 1, Part 2 and Part 5

Expires: 20 October 2013

MED 0850297 USCG/ MRA 164.117

Tarkett Polska Spo?ka z Ograniczona Odpowiedzialnoscia, Oddzial w Jasle, Ul.M ickiewicza 108, 38-200 Jaslo, Poland.

Floor Covering – Type: “ Contract Plus” M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88) (2010 FTP Code), Annex 1, Part 2 and Part 5.

Expires: 27 February 2022

MED 1750031/ M1

Floor covering – Type: “ Centra 43” M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88) (2010 FTP Code), Annex 1, Part 2 and Part 5.

Expires: 27 February 2022

MED 1750032/ M1

Thailand Carpet M anufacturing Public Company Limited, 238 Vipavadee Rangsit Road, Sanambin, Donmung, Bangkok, 10210, Thailand.

Fire Resisting Floor Covering Material – Type: “ 100% Wool Hand Tufted Carpet”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS AND NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE AND TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 12 August 2020

MED 1550204

Page 140: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18c SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - FLOOR COVERI

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

140 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

The Amtico Company Limited, Kingfield Road, Coventry, West M idlands, CV6 5AA, United Kingdom (UK).

Fire Resisting Floor Covering Material – Type: “ Amtico Marine (1-07)”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 2 and Part 5 MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 27 September 2021

MED 1650248

Torginol - Teollisuuslattiat OY, Billskogintie 31, FI -02580 Siuntio, Finland.

Fire Resisting Multi-layered Floor Covering – Type: “ Marine Coating System T6”

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS AND NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE AND TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC.307(88)-(2010 FTP Code) Annex 1, Part 2 and Part 5

Expires: 17 September 2021

MED 1650225

Page 141: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18d SURFACE M ATERIALS AND FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - PIPE INS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

141 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fiba Tech Industries Ltd., Willmotts Business Park, Waterlip, Somerset, BA4 4RN, United Kingdom (UK).

Fire Resisting Material – Type “ FibaRoll FRM1” UV Curing Glass Fibre Reinforced Polyester Resin sheet

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 2 and Part 5 IMO MSC/ Circ.1120

Expires: 13 June 2016

MED 1150167

Innovative M anufacturing, 861 Derwent Way, Delta, British Columbia, V3M 5R4, Canada.

Fire Resisting Material – Type: “ Exo Wrap Insulation with foil scrim and Exo Wrap Silhesive Tape” - For applications as pipe insulation material

M ATERIAL HAVING LOW FLAM E CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res. MSC. 61(67)-(FTP Code) Annex 1, Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – 2010 Fire Test Procedures Code, Section 8

Expires: 4 September 2021

MED 1650202

Temp Coat Brand Products LLC, 301 W. Airline hwy., Suite 100, LaPlace, LA, 70068, United States of America (USA).

Fire Resisting Material - Type: “ TEMP-COAT 101 “ vapour barrier coating

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 2 and Part 5 IMO MSC/ Circ 1120 IMO Res. MSC.307(88) – 2010 FTP Code, Section 8

Expires: 14 July 2021

MED 1650222

Page 142: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.18e SURFACE M ATERIALS & FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - ADHESIVES (A

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

142 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

ATIS International B.V., Noordhoek 33, 3351 LD Papendrecht, Netherlands, The.

Fire Resisting Material– Type: “ Caldivibro CLD” self adhesive metallic sheet

M ATERIAL HAVING LOW FLAM E SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SM OKE & TOXIC PRODUCTS OF COM BUSTION

IMO Res.MSC.61 (67) - (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Part 8

Expires: 30 March 2022

MED 1750008/ M2

Bijlard International, P.O.Box 398, 2700 AE Zoetermeer, Platinastraat 141, 2718 SR Zoetermeer, Netherlands, The.

Fire Resisting Adhesive – Type: “ Bijlard Spuitli jm(sprayable contact glue) Rood (Red)” or “ Ankerweld Spuitli jm (sprayable contact glue) 2344 R”

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 14 May 2017

MED 1250090

L'Isolante K-Flex Srl, Via Leonardo da Vinci, 36, 20877 Roncello (M i), I taly.

Fire Resisting Material - Type: “ K-Flex IN-CLAD“ Elastomeric Foam Insulation

Material having Low Flame Spread Characteristics

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 5 IMO MSC/ Circ 1120

Expires: 13 June 2016

MED 1150278

Fire Resisting Material - Type: “ K-Flex IC-CLAD“ Elastomeric Foam Insulation

Material Having Low Flame Spread Characteristics & Not Capable Of Producing Excessive Quantities Of Smoke & Toxic Products Of Combustion

IMO Res. MSC.61(67) – (FTP Code), Annex 1, Part 5 and Annex 2 IMO MSC/ Circ 1120

Expires: 13 June 2016

MED 1150279 And

USCG Module B number:

164.112/ EC0038

SM Tech Co Ltd, 556-15 Daeyeon-dong, Nam-gu, Busan, 608-810, Korea, Republic of.

Fire Resisting Material- Type: ‘3M 480FR Industrial FR Grade Silicone Sealant’

MATERIAL HAVING LOW FLAME SPREAD CHARACTERISTICS & NOT CAPABLE OF PRODUCING EXCESSIVE QUANTITIES OF SMOKE & TOXIC PRODUCTS OF COMBUSTION

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 5 and Annex 2 IMO MSC/ Circ.1120

Expires: 12 July 2015

MED 1050168

Page 143: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.19 DRAPERIES, CURTAINS & OTHER SUSPENDED TEXTILE M ATERIALS AND FILM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

143 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Bru Textiles, Satenrozen 2A, B-2550 Kontich, Belgium.

Fire Resisting Curtain or Drapery Fabrics – Types: “ FR One Architectural, FR One Brilliance, FR One Calais, FR One Eclipse, FR One Essence, FR One Essential, FR One Lux, FR One Nevada, FR One Orangerie, FR One Romance, FR One Web, FR One Skylight ”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAM E

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 7 IMO MSC/ Circ.1120

Expires: 6 July 2015

MED 1050163/ M1

Fire Resisting Curtain or Drapery Fabrics – Types: “ FR One Equinox, FR One Ping, FR One Trinity, FR One Zest, FR One Zora”

MATERIALS HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAME

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 7 IMO MSC/ Circ.1120

Expires: 6 July 2015

MED 1050164

Fire Resisting Curtain or Drapery Fabrics – Type: “ FR One Excalibur”

MATERIALS HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAME

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 7 IMO MSC/ Circ.1120

Expires: 6 July 2015

MED 1050165

Draperies, curtains and other suspended textile material and films – Types: “ Timber, Ribera, Candor, Filos, Iceberg, FR One Fontana, FR One Freedom, FR One Hospitality, FR One Naturopia”

Material Having Qualities Of Resistance To The Propagation Of Flame

IMO Resolution MSC.61(67) – (FTP Code) Annex 1 Part 7 IMO MSC/ Circ.1120

Expires: 18 November 2015

MED 1050340 And USCG Module B No: 164.111/ EC0038

Draperies, curtains and other suspended textile material and films – Types: “ FR One Kadelio - Rainbow Stripe, FR One Woo - Cadmiun, FR One Woo - Cerium and FR One Woo - Francium”

Material Having Qualities Of Resistance To The Propagation Of Flame

IMO Resolution MSC.61(67) – (FTP Code) Annex 1 Part 7 IMO MSC/ Circ.1120

Expires: 18 November 2015

MED 1050341 And USCG Module B Number: 164.111/ EC0038

Page 144: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.19 DRAPERIES, CURTAINS & OTHER SUSPENDED TEXTILE M ATERIALS AND FILM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

144 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Draperies, curtains and other suspended textile material and films – Types: “ Prize” , “ Accolade” , “ Cup” , “ Sublime” , “ Attavanti” , “ Palmieri” , “ Marengo” and “ Magdalena”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAM E

IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 7 IMO MSC/ Circ 1102 IMO MSC/ Circ 1120 IMO Res. MSC.307 (88) - (2010 FTP Code) Section 8 (Period of Grace)

Expires: 15 November 2016

MED 1150303/ M1

Draperies, curtains and other suspended textile material and films – Types: “ Salina” , “ Lipari” , “ Gaggi” , “ Corvaja”

MATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAME

IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 7 IMO MSC/ Circ 1102 IMO MSC/ Circ 1120

Expires: 15 November 2016

MED 1150304

Page 145: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.19 DRAPERIES, CURTAINS & OTHER SUSPENDED TEXTILE M ATERIALS AND FILM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

145 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Bru Textiles ...continued Draperies, curtains and other suspended textile material and films – Types: “ Mission” , “ Keaton” , “ Torrini” , “ Divina” , “ Dante” , “ Boccaccio” , “ Delis” , “ Cora” , “ Helio” , “ Attica” , “ Dorian” , “ Blockbuster” , “ Corfu” , “ Lucca” , “ Abdallo” , “ Abigaille” , “ Fenena” , “ Ismaele” , “ Zaccaria” , “ Baal” , “ Euphrates” , “ Anna” , “ Nali” , “ Nyx” , “ Baryon” , “ Dagian” , “ Dark” , “ Dawn” , “ Dusk” , “ Lepton” , “ Oxymore” , “ Scuro” , “ Sfumato” , “ Stars” , “ Ausonius” , “ Buzzi” , “ Cesare” , “ Hippo” , “ Augustine” , “ Perlo” , “ Perlhi” , “ Secure” , “ Extreme”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAM E

IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 7 IMO MSC/ Circ 1102 IMO MSC/ Circ 1120

Expires: 23 June 2018

MED 1350086

Draperies, curtains and other suspended textile material and films – Types: “ Secrets” , “ Sheerpedia” , “ Offa” , “ Gossy”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAM E

IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 7 IMO MSC/ Circ 1102 IMO MSC/ Circ 1120

Expires: 23 June 2018

MED 1350087

Draperies, curtains and other suspended textile material and films – Types: “ Plain Woven Group: FR-One Vanguard (Vaillant, Valhalla), FR-One Vanity (Admiration, Pride, Sleek, Superbia), FR-One Vittoria (Valor, Verel, Verve, Vertu, Volvox, Vortex), FR-One Venere (Valeria, Valona, Verena), FR-One Vivabella (Uma, Vantage, Vision, Volute, Wizard), FR-One Waldorf (Tsar, Vivaldo, Waltz, Zaza, Zefiro) and FR-One Wynnshire (Vic)”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAM E

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 7

Expires: 19 November 2019

MED 1450255/ M1

Page 146: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.19 DRAPERIES, CURTAINS & OTHER SUSPENDED TEXTILE M ATERIALS AND FILM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

146 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Draperies, curtains and other suspended textile material and films – Type: “ Sheers: FR-One Voila (Solitaire, Valence, Vicomte, Villeroy) and FR-One Volare (Sway, Webledon)”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAM E

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 7

Expires: 19 November 2019

MED 1450256

Draperies, curtains and other suspended textile material and films – Type: “ FR-One Blackout FR”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAM E

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 7

Expires: 19 November 2019

MED 1450257

Page 147: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.19 DRAPERIES, CURTAINS & OTHER SUSPENDED TEXTILE M ATERIALS AND FILM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

147 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Dong Young Industries Co. Ltd, 200-9 M angmi-Dong, Sooyoung-Ku, Busan 613-820, Korea, Republic of.

Fire Resisting Material – Type: “ DY Curtain and Shower Curtain Special Textile” w ith 24 colour patterns as described in the Design Appraisal Document

Material having Qualities of Resistance to the Propagation of Flame

IMO Res. MSC. 61(67)-(FTP Code) Annex 1, Part 7 IMO MSC/ Circ 1120

Expires: 10 December 2017

USCG Module B number:

164.111/ EC0038

MED 1250259

M anifattura A Testori di G SpA, Via Dante 7, 20026 Novate M ilanese (M ilano), I taly.

Fire Resisting Material – Type: “ ART.8200 Curtain”

Material Having Qualities of Resistance to the Propagation of Flame

IMO Res. MSC.61 (67)-(FTP Code) Annex 1, Part 7 IMO MSC/ Circ.1102. IMO MSC/ Circ.1120.

Expires: 14 February 2016

MED 1150071And

USCG Module B number:

164.111/ EC0038

Shanghai Leading Industrial Company Limited, Rm 18c No. 2000 Pudong Da Dao, Free Trade Zone (Shanghai), Shanghai 200135, China, People's Republic of.

Draperies, curtains and other suspended textile material and films – Type: “ Safe Marine”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAM E

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 7

Expires: 27 March 2022

MED 1750060

Page 148: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.19 DRAPERIES, CURTAINS & OTHER SUSPENDED TEXTILE M ATERIALS AND FILM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

148 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shin Heung ENG Co, 3756-1A, C-Dong, #3756, Gangdong-dong, Gangseo-gu, Busan, Korea, Republic of.

Fire Resisting Curtain Fabric – Type: “ SH-CK”

Material having Qualities of Resistance to the Propagation of Flame

IMO Fire Test Procedures Code, Annex 1, Part 7

Expires: 23 July 2017

MED 1250133/ M1

And USCG Module

B No. 164.111/ EC003

8

Fire Resisting Curtain Fabric – Type: “ SH-SK”

Material having Qualities of Resistance to the Propagation of Flame

IMO Fire Test Procedures Code, Annex 1, Part 7

Expires: 28 July 2017

MED 1250135/ M1

And USCG Module

B No. 164.111/ EC003

8

Shin Heung Eng Co., 11 Gangdongjunggok, 2 Gil, Gangseo-Gu, Busan 618-802, Korea, Republic of.

Fire Resisting Shower Curtain – Type: “ SH-SCK”

MATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAME

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 7

Expires: 9 August 2021

MED 1650206/ M1

Page 149: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.2 PORTABLE FIRE EXTINGUISHERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

149 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Eversafe Extinguisher Sdn Bhd, Lot 878, Jalan Subang 9, Taman Perindustrian Subang, 47500 Subang Jaya, Selangor Darul Ehsan, M alaysia.

EVERSAFE, FireSafe, Red Panther, and BRUDE Safety Portable Fire Extinguisher – Type: “ EED-6c, EED-9c, EED-12c” Dry Chemical Powder Fire Extinguishers

A.1/ 3.2 - Portable Fire Extinguishers A.1/ 3.38 – Portable Fire-Extinguishing Equipment For Lifeboats & Rescue Boats

EN 3-6 (1995) including A.1 (1999) EN 3-7 (2004) including A.1 (2007) EN 3-8 (2006) including AC (2007)

Expires: 27 June 2015

MED 1050152/ M1

EVERSAFE, FireSafe, Red Panther, and BRUDE Safety Portable Fire Extinguisher – Type: “ EED-1, EED-2, EED-2h, EED-3, EED-4N, EED-6, EED-9, EED-12” Dry Chemical Powder Fire Extinguishers

A.1/ 3.2 – portable fire extinguishers A.1/ 3.38 – portable fire-extinguishing equipment for lifeboats & rescue boats

EN 3-6 (1995) including A.1 (1999) EN 3-7 (2004) including A.1 (2007) EN 3-8 (2006) including AC (2007)

Expires: 27 June 2015

MED 1050153/ M1

EVERSAFE, FireSafe, Red Panther, and BRUDE Safety Portable Fire Extinguisher – Type: “ EEC-2Ale2, EEC-2e2, EEC-5Ale1, EEC-5e1, EEC-6.8” Carbon Dioxide Fire Extinguishers

Portable Fire Exintinguishers & Portable Fire-Extinguishing Equipment For Lifeboats & Rescue Boats (A.1/ 3.2 & A.1/ 3.38)

EN 3-6 (1995) including A.1 (1999) EN 3-7 (2004) including A.1 (2007) EN 3-9 (2006)

Expires: 19 August 2015

MED 1050211

EVERSAFE, FireSafe, Red Panther, and BRUDE Safety Portable Fire Extinguisher – Type: “ EEW-6cs & EEW-9cs” Water Fire Extinguishers

A.1/ 3.2 - Portable Fire Extinguishers AND A.1/ 3.38 – Portable Fire-Extinguishing Equipment For Lifeboats & Rescue Boats

EN 3-6 (1995) including A.1 (1999) EN 3-7 (2004) including A.1 (2007) EN 3-8 (2006) including AC (2007)

Expires: 11 October 2015

MED 1050282

EVERSAFE, FireSafe, Red Panther, and BRUDE Safety Portable Fire Extinguisher – Type: “ EEW-6s & EEW-9s” Water Fire Extinguishers

A.1/ 3.2 – Portable fire extinguishers AND A.1/ 3.38 – Portable Fire-Extinguishing Equipment For Lifeboats & Rescue Boats

EN 3-6 (1995) including A.1 (1999) EN 3-7 (2004) including A.1 (2007) EN 3-8 (2006) including AC (2007)

Expires: 11 October 2015

MED 1050283

Page 150: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.2 PORTABLE FIRE EXTINGUISHERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

150 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

EVERSAFE, FireSafe, Red Panther, and BRUDE Safety Portable Fire Extinguisher – Type: “ EEF-6cs, EEF-9cs, EEF-9c” Foam Fire Extinguishers

A.1/ 3.2 - Portable Fire Extinguishers AND A.1/ 3.38 – Portable Fire-Extinguishing Equipment For Lifeboats & Rescue Boats

EN 3-6 (1995) including A.1 (1999) EN 3-7 (2004) including A.1 (2007) EN 3-8 (2006) including AC (2007)

Expires: 11 October 2015

MED 1050284

EVERSAFE, FireSafe, Red Panther, and BRUDE Safety Portable Fire Extinguisher – Type: “ EEF-2s, EEF-6s, EEF-9s” Foam Fire Extinguishers

A.1/ 3.2 – Portable fire extinguishers AND A.1/ 3.38 – Portable Fire-Extinguishing Equipment For Lifeboats & Rescue Boats

EN 3-6 (1995) including A.1 (1999) EN 3-7 (2004) including A.1 (2007) EN 3-8 (2006) including AC (2007)

Expires: 11 October 2015

MED 1050285

Extintores Faex S.L., Pol. Ind. "El Aguila", C/Rumanía Naves 24-25, 50180 Utebo (Zaragoza), Spain.

Portable Fire Extinguisher – Type: EXTINTORES FAEX “ PI-3 and PI-6S” Dry Chemical Powder Fire Extinguishers

PORTABLE FIRE EXTINGUISHER EN 3-6 (1995) including A.1 (1999) EN 3-7 (2004) including A.1 (2007) EN 3-8 (2006) including AC (2007)

Expires: 5 May 2019

MED 1450139

Page 151: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.20 UPHOLSTERED FURNITURE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

151 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Andrew M uirhead & Son Limited, 273-289 Dunn Street, Glasgow, G40 3EA, United Kingdom (UK).

Fire Resisting Material – Type: “ Aniline & Pigmented Leather Hides” Upholstery Material

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAM E

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 8 IMO MSC/ Circ.1120

Expires: 2 November 2015

MED 1050061/ M2

Bru Textiles, Satenrozen 2A, B-2550 Kontich, Belgium.

Fire Resisting Upholstery Fabric and Filling Material – Types: “ FR One Endurance and FR One Excalibur”

MATERIALS HAVING QUALITIES OF RESISTANCE TO IGNITION AND PROPAGATION OF FLAME

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 8 IMO MSC/ Circ.1120

Expires: 6 July 2015

MED 1050166

Upholstered Furniture Fire Resisting Material – Types: “ Timber” and “ Candor”

Material Having Qualities Of Resistance To The Propagation Of Flame

IMO Resolution MSC.61(67) – (FTP Code) Annex 1 Part 8 IMO MSC/ Circ.1120

Expires: 18 November 2015

MED 1050339 And USCG Module B Number: 164.144/ EC0038

Upholstered Furniture Fire Resisting Material – Types: “ Classico” , “ Blade” , “ Razor” , “ Riptide” , “ Supra” , “ Lola” , “ Award” , “ Honour” , “ Attavanti” , “ Palmieri” , “ Marengo” , “ Magdalene”

MATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAME

IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 8 IMO MSC/ Circ.1102 IMO MSC/ Circ.1120

Expires: 15 November 2016

MED 1150302

Upholstered Furniture Fire Resisting Material – Types: “ Chieftain” , “ Kavalier” , “ Houdini” , “ Mystery” , “ Plush”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAM E

IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 8 IMO Res. MSC.307(88) - (2010 FTP Code) Annex 1, Part 8

Expires: 23 June 2018

MED 1350088/ M1

Upholstered Furniture Fire Resisting Material – Types:“ FR-One Velluti (Vanquish, Vavasour, Vervel, Virelay, Vizir), FR-One Whaoo and FR-One Wynnshire (Wynn)”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAM E

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 8

Expires: 19 November 2019

MED 1450253

Page 152: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.20 UPHOLSTERED FURNITURE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

152 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Dong Young Industries Co. Ltd, 200-9 M ang M i-Dong, Su Young-Gu, Busan, 613-130, Korea, Republic of.

Fire Resisting Upholstery Fabric – Type: “ DY(F-1) Special Textile” w ith 20 colour patterns as described on the Design Appraisal Document

MATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAME

IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 8 IMO MSC/ Circ.1120

Expires: 1 April 2017

MED 1250060/ M1

Fabryka M ebli Okretowych FAM OS Sp z.o.o, ul Gdanska 37, 83-200 Starogard, Gdanski, Poland.

Fire Resisting Upholstery Fabric – Type: “ NINO”

Material Having Qualities Of Resistance To The Ignition And Propagation Of Flame

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 8 IMO MSC/ Circ.1120

Expires: 26 March 2017

MED 1250017

Page 153: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.20 UPHOLSTERED FURNITURE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

153 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fabryka M ebli Okretowych FAM OS Sp z.o.o ...continued

Fire Resisting Upholstery Fabric – Type: “ LAGO”

Material having Qualities of Resistance to the Ignition and Propagation of Flame

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 8 IMO MSC/ Circ.1120

Expires: 26 March 2017

MED 1250018

M ajilite Corporation, 1530 Broadway Road, Dracut, M assachusetts 01826 - 2830, United States of America (USA).

Fire Resisting Upholstery Grade Faux Leathers – Type: “ Nytek IMO 652 FR Knit”

Material having qualities of resistance to the propagation of flame

IMO Res. MSC.61(67) (FTP Code) Annex 1 Part 8 IMO MSC/ Circ.1120

Expires: 29 September 2015

MED 1050268 And USCG Module B No: 164.144/ EC0038

Fire Resisting Upholstery Grade Faux Suede’s – Type: “ Novasuede IMO 652”

Material having Qualities of Resistance to the Ignition and Propagation of Flame

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 8 IMO MSC/ Circ.1120

Expires: 20 December 2016

MED 1150330

Fire Resisting Upholstery Grade Faux Suede’s – Type: “ Novasuede IMO 652”

Material having Qualities of Resistance to the Ignition and Propagation of Flame

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 8 IMO MSC/ Circ.1120

Expires: 20 December 2016

MED 1150331

Fire Resisting Upholstery Grade Faux Leather’s – Type: “ Nytek IMO 652 DC”

MATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAME

IMO Res. MSC.307(88) - FTP Code, Annex 1, Part 8 IMO MSC/ Circ.1120

Expires: 28 August 2017

MED 1250147

Upholstered Furniture Fire Resisting Material – Type: “ Novasuede IMO652 DC”

MATERIAL HAVING QUALITIES OF RESISTANCE TO THE PROPAGATION OF FLAME

IMO Res. MSC 307(88) - (2010 FTP Code) Annex 1 Part 8

Expires: 3 April 2018

MED 1350047

M anifattura A Testori di G SpA, Via Dante 7, 20026 Novate M ilanese (M ilano), I taly.

Fire Resisting Material – Type: “ ART.8800 – Upholstery Fabric”

Material Having Qualities of Resistance to the Ignition and Propogation of Flame

IMO Res. MSC.61 (67)-(FTP Code) Annex 1, Part 8. IMO MSC/ Circ.1102. IMO MSC/ Circ.1120.

Expires: 14 February 2016

MED 1150063

Page 154: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.20 UPHOLSTERED FURNITURE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

154 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Material – Type: “ ART8650 – Upholstery Velvet in Trevira CS”

Material Having Qualities of Resistance to the Ignition and Propogation of Flame

IMO Res. MSC.61 (67)-(FTP Code) Annex 1, Part 8. IMO MSC/ Circ.1102. IMO MSC/ Circ.1120.

Expires: 14 February 2016

MED 1150064

And USCG

Module B number:

164.144/ EC0038

Upholstered Furniture Fire Resisting Material – Type: “ ART 8400”

Material having Qualities of Resistance to the Ignition and Propagation of Flame

IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 8 IMO MSC/ Circ.1102 IMO MSC/ Circ. 1120

Expires: 3 July 2016

MED 1150287

Page 155: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.20 UPHOLSTERED FURNITURE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

155 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shin Heung ENG Co, 3756-1A, C-Dong, #3756, Gangdong-dong, Gangseo-gu, Busan, Korea, Republic of.

Fire Resisting Upholstery Fabric and Filling Material – Type: “ SH-FK”

Material having Qualities of Resistance to the Ignition and Propagation of Flame

IMO Fire Test Procedures Code, Annex 1, Part 8

Expires: 23 July 2017

MED 1250134/ M1

And USCG Module

B Number: 164.144

Fire Resisting Upholstery Fabric and Filling Material – Type: “ SH-VK”

Material having Qualities of Resistance to the Ignition and Propagation of Flame

IMO Fire Test Procedures Code, Annex 1, Part 8

Expires: 23 July 2017

MED 1250136/ M1

And USCG Module

B No: 164.144/ EC003

8

Shin Heung Eng Co., 11 Gangdongjunggok, 2 Gil, Gangseo-Gu, Busan 618-802, Korea, Republic of.

Upholstered Funiture Fire Resisting Materials - Types: “ SH-ACH and SH-BCH” leather upholstery and “ SH-S” foam fill ing material

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAM E

IMO Res. 307(88) - (2010 FTP Code) Annex 1, Part 8

Expires: 14 September 2019

MED 1450189

Spradling International GmbH, Walter-Boetcher-Str.7, D-21337 Lüneburg, Germany.

Fire-Resisting Upholstery Material – Type “ Spradling Collection Nylon”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPOGATION OF FLAM E

IMO Res. MSC.61(67) – ( FTP Code) Annex 1 Part 8 IMO MSC/ Circ. 1120

Expires: 23 January 2017

MED 1250007/ M1

Page 156: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.20 UPHOLSTERED FURNITURE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

156 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire-Resisting Upholstery Material – Type “ Spradling Collection”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPOGATION OF FLAM E

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 8 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8 IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 8

Expires: 16 June 2020

MED 1550237/ M3

Stjernemadrassen AS, Kaivegen 5, N-6220 Straungjerde, Norway.

Fire Resisting Mattress – Type: “ STJERNE OFFSHORE”

UPHOLSTERED FURNITURE

IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 9 IMO MSC/ Circ.1120

Expires: 3 June 2017

MED 1250102

Page 157: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.20 UPHOLSTERED FURNITURE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

157 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Summit Chairs Ltd, Treenwood Industrial Estate, Bradford On Avon, Wiltshire, BA15 2AU, United Kingdom (UK).

Fire Resisting Upholstery Material – Type: “ Camira 24/ 7” fabric covering for use with any of the following foam fillings, type: “ HR 50/ 230” or type: “ Vita HR35 105” or type: “ Vita VE33 175” .

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAM E

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 8 IMO MSC/ Circ.1120

Expires: 5 July 2017

MED 1250117

Fire Resisting Upholstery Material – Type: “ Drapilux 7801002” fabric covering for use with any of the following foam fillings, type: “ HR 50/ 230” or type: “ Vita HR35 105” or type: “ Vita VE33 175” .

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAM E

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 8 IMO MSC/ Circ.1120

Expires: 5 July 2017

MED 1250118

Vescom B.V., St. Jozefstraat 20, 5753 AV Deurne, Netherlands, The.

Upholstered Furniture Fire Resisting Material – Type: “ Vinyl Fabric – Ref T706040”

Material Having Qualities of Resistance to the Ignition and Propagation of Flame

IMO Fire Test Procedures Code, Annex 1, Part 8

Expires: 4 October 2012

MED 0750220 And

USCG Module B number:

164.144/ EC0038

Page 158: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.21 BEDDING COM PONENTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

158 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Dong Young Industries Co. Ltd, 200-9 M ang M i-Dong, Su Young-Gu, Busan, 613-130, Korea, Republic of.

Fire Resisting Bedding Material – Type: “ DY-Mattress”

MATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAME

IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 9 IMO MSC/ Circ.1120

Expires: 1 April 2017

MED 1250061

Fabryka M ebli Okretowych FAM OS Sp z.o.o, ul Gdanska 37, 83-200 Starogard, Gdanski, Poland.

Fire Resisting Material – Type: “ KK18-94/ M-139-005 with covering fabrics LAGO and NINO

Material having qualities of resistance to the ignition and propagation of flame

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 9 IMO MSC/ Circ.1120

Expires: 2 July 2017

MED 1250106

And USCG

Module B number:

164.142/ EC0038

Fire Resisting Material – Type: “ KK18-96-M-139-006 with covering fabrics LAGO and NINO

Material having qualities of resistance to the ignition and propagation of flame

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 9 IMO MSC/ Circ.1120

Expires: 2 July 2017

USCG Module B number:

164.142/ EC0038

MED 1250108

Intertras Bedding BV, Orionweg 11, 9641 M N Veendam, Netherlands, The.

Fire Resisting Bedding – Type: “ FR Grade Basofill Fabric Cover applied over Foam/ Bonnel Spring/ Pocket Spring Mattresses”

MATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAME

IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 9 IMO MSC/ Circ.1120

Expires: 6 September 2016

MED 1150256

Fire Resisting Bedding – Type: “ FR Grade M asterflam Fabric Cover applied over Foam/Bonnel Spring/Pocket Spring M attresses”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAM E

IMO Res.MSC.61(67) - (FTP Code) Annex 1 Part 9 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 6 September 2021

MED 1650146

Page 159: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.21 BEDDING COM PONENTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

159 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

JM B Sp. z.o.o., ul. Polna 1, 84-240 Wejherowo, Poland.

** NO CERT **

Fire Resisting Mattress – Type ‘’M-MP’’

MATERIALS HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAME – BEDDING COMPONENTS

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 9 IMO MSC/ Circ.1120

Expires: 18 March 2017

MED 1250043

Bedding Components – Type: “ M-MS2” Mattress

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAM E

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 9 IMO MSC/ Circ 1102 IMO MSC/ Circ 1120

Expires: 1 October 2017

MED 1250189

Page 160: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.21 BEDDING COM PONENTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

160 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

JM B Sp. z.o.o. ...continued Fire Resisting Material – Type: “ SPRING MATTRESS M-MS”

Material Having Qualities of Resistance to the Ignition and Propogation of Flame - Bedding Components

IMO Resolution MSC.61(67) – (FTP Code) Annex 1 Part 9 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 11 October 2020

MED 1550245

M anifattura A Testori di G SpA, Via Dante 7, 20026 Novate M ilanese (M ilano), I taly.

Fire Resisting Material – Type: “ ART.8900 – Bedcover”

Material Having Qualities of Resistance to the Ignition and Propogation of Flame

IMO Res. MSC.61 (67)-(FTP Code) Annex 1, Part 9 IMO MSC/ Circ.1102. IMO MSC/ Circ.1120.

Expires: 14 February 2016

MED 1150065

And USCG

Module B number:

164.142/ EC0038

Shanghai Leading Industrial Company Limited, Rm 18c No. 2000 Pudong Da Dao, Free Trade Zone (Shanghai), Shanghai 200135, China, People's Republic of.

Fire Resisting Bedding Material- Type: ” SAFE-MARINE MATTRESS”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAM E

IMO Res.MSC.307(88)-(2010 FTP Code) Annex 1 Part 9

Expires: 31 March 2021

MED 1650112

Page 161: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.21 BEDDING COM PONENTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

161 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shin Heung ENG Co, 3756-1A, C-Dong, #3756, Gangdong-dong, Gangseo-gu, Busan, Korea, Republic of.

Fire Resisting Bedding Material – Type: “ Polyurethane Mattress for Marine”

Material Having Qualities of Resistance to the Ignition and Propagation of Flame

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 9 IMO MSC/ Circ.1102 IMO MSC/ Circ.1120

Expires: 23 July 2017

MED 1250137/ M1

And USCG Module

B number: 164.142/ EC003

8

Fire Resisting Bedding Material – Type: “ Spring Mattress for Marine”

Material Having Qualities of Resistance to the Ignition and Propagation of Flame

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 9 IMO MSC/ Circ.1102 IMO MSC/ Circ.1120

Expires: 23 July 2017

MED 1250138/ M1

And USCG Module

B number: 164.142/ EC003

8

Shin Heung Eng Co., 11 Gangdongjunggok, 2 Gil, Gangseo-Gu, Busan 618-802, Korea, Republic of.

Fire Resisting Bedding Material - Type: “ SH-PK, SH-TK, SH-DK”

M ATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAM E

IMO Res. 307(88) - (2010 FTP Code) Annex 1 Part 9

Expires: 2 October 2019

MED 1450200

Page 162: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.21 BEDDING COM PONENTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

162 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shin Heung Eng Co. ...continued

Fire Resisting Bedding – Type: “ Spring Mattress for Marine, Spring Mattress(Pocket type) Mattress, Polyurethane Mattress for Marine"

MATERIAL HAVING QUALITIES OF RESISTANCE TO THE IGNITION AND PROPAGATION OF FLAME

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 9

Expires: 9 August 2021

MED 1650207/ M1

Page 163: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.22 FIRE DAM PERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

163 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

ACTIONAIR, South Street, Whitstable, Kent, CT5 3DU, United Kingdom (UK).

Single/ Multi Blade Fire Damper – Type ‘’A-60 Marine’’

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 12 June 2017

USCG Module B number: 164.139/ EC0038 MED 1250101

FCD Systems Limited, Causeway House, 1 Dane Street, Bishop's Stortford, Hertfordshire, United Kingdom (UK).

Single/ Multi Bladed Fire Damper – Type: “ MFD-A-60” , for use in Steel Bulkheads and Decks

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 27 February 2017

MED 1250024/ M4

Flamgard Engineering Ltd, Unit 2-4 Gemini Works, Estate Road, Pontypool, NP4 6YW, United Kingdom (UK).

Multi Blade Fire Damper – Type: “ CFD-01”

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res.MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 26 June 2016

MED 1150201

Single/ Multi Blade Fire Damper – Type: “ FD-02”

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res MSC 61(67) – (FTP Code) Annex 1, Part 3 IMO MSC Circ. 1120

Expires: 10 February 2018

MED 1350020

Multi Blade Rectangular Fire Damper – Type: “ CFD – 01”

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.307(88) 2010 FTP Code, Annex 1, Part 3

Expires: 14 August 2018

MED 1350110

Multi Blade Rectangular Fire Damper – Type: “ CFD – 01”

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.307(88) 2010 FTP Code, Annex 1, Part 3

Expires: 9 September 2018

MED 1350119

Multi Blade Rectangular Fire Damper – Type: “ CFD – 02”

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) 2010 FTP Code, Section 8

Expires: 12 January 2018

MED 1450168

Page 164: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.22 FIRE DAM PERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

164 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

ISOL.M E.CAR. Srl, Via dei Bagni Nuova, 5, Zona Industriale Schiavetti, 34074 - M onfalcone (Gorizia), I taly.

Multi Bladed Rectangular Fire Dampers - Types: 1, 2, 2A (for A-0 only) and 3 for Applications in Steel decks

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 13 December 2020

MED 1650041

Multi Bladed Rectangular Fire Dampers – Type: 1, 2A (For A-0 only), 3 and 4 for Applications in Steel Bulkheads

Fire Damper (Standard Fire Test) IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 13 December 2020

MED 1650042

Page 165: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.22 FIRE DAM PERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

165 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jiangsu Zhaosheng Air Conditioning Co. Ltd, 18-28 Tongjiang Road, Taixing City, Jiangsu, 225441, China, People's Republic of.

Single-bladed Rectangular Fire Dampers - Types: ” CSFH” and “ CDFH” in bulkhead applications only.

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res.MSC.307(88) - (2010 FTP Code) Annex 1, Part 3

Expires: 16 September 2021

MED 1650292

Multi-bladed Circular Fire Dampers- Type: ” CQFHD” in bulkhead applications only.

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res.MSC.307(88) - (2010 FTP Code) Annex 1, Part 3

Expires: 16 September 2021

MED 1650293

Mulitple Blade Fire Damper – Type: “ CQFHD” and “ CSFHD” for use in Bulkheads

Fire Dampers IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 19 February 2011

MED 0650040

And USCG

Module B number:

164.139/ EC0038

Single Blade Fire Damper – Type: “ CSFH” and “ CDFH” for use in steel bulkheads

FIRE DAMPER (STANDARD FIRE TEST)

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ. 1120 IMO Res.MSC.307 (88) - (2010 FTP Code) Section 8

Expires: 23 September 2021

MED 1750023

Page 166: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.22 FIRE DAM PERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

166 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Kanagawa Iron Works Co., Ltd., 3-73 Chome, Takasago, Takaishi-shi, Osaka, 592-0001, Japan.

Single and Multi-bladed Fire Dampers – Type: “ KW-4.5”

Fire Damper (Standard Fire Test) IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) - (2010 FTP Code), Section 8

Expires: 8 July 2019

MED 1450177

M arinefire s.r.l., Via Grecale 33, 55049 Viareggio (LU), I taly.

Single/ Multi Blade Rectangular Fire Damper – Type: “ MFD A60 Marine Fire Damper”

Fire Damper (Standard Fire Test) IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 12 June 2017

MED 1250157/ M1

Ruskin Air M anagement LTD (Actionair), Joseph Wilson Industrial Estate, South Street, Whitstable, Kent, CT5 3DU, United Kingdom (UK).

Single or Multi Bladed Rectangular Fire Damper – Type ‘’A-60 Marine Fire Damper’’ for use in steel bulkheads and decks.

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.307(88) – (FTP Code) Annex 1, Part 3

Expires: 24 November 2021

MED 1650283

Page 167: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.22 FIRE DAM PERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

167 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Swegon Air M anangement Ltd (Actionair), Joseph Wilson Industrial Estate, South Sreee, Whitstable, Kent, CT53 DU, United Kingdom (UK).

Single or Multi Bladed Rectangular Fire Damper – Type ‘’A-60 Marine Fire Damper’’ for use in steel bulkheads and decks

FIRE DAMPER (STANDARD FIRE TEST

IMO Res. MSC.307(88) – (FTP Code) Annex 1, Part 3 IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 12 April 2022

MED 1750068

Taixing City Ocean M achinery M anufacture Co Ltd, Jiangzha Yanjiang Economic Development Zone, Taixing City, Jiangsu, 225443, China, People's Republic of.

Single And Multi-Bladed Rectangular Fire Damper with Insulated Blades – Type:” CDHA-Sa/ S/ Q” for Bulkhead Applications only

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88)-(2010FTP Code) Section 8

Expires: 22 March 2020

MED 1650045

Single And Multi-Bladed Rectangular Fire Damper with Insulated Blades – Type:” CDH-S/ Sa/ Q/ Qa/ Z” for Bulkhead Applications only

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88)-(2010FTP Code) Section 8

Expires: 22 March 2020

MED 1650046

Single Bladed Circular Fire Damper with Insulated Blades – Type: ” CDHA-Sa” for Bulkhead Applications only

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88)-(2010FTP Code) Section 8.

Expires: 22 March 2020

MED 1650047

Page 168: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.22 FIRE DAM PERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

168 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Single Bladed Circular Fire Damper with Uninsulated Blades – Type: ” CDH-S/ D” for Bulkhead Applications only

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88)-(2010FTP Code) Section 8.

Expires: 22 March 2020

MED 1650048

TROX M alaysia Sdn. Bhd., 20 Persiaran Bunga Tanjung 1, Senawang Land Industrial Park, 70400 Seremban, Negeri Sembilan, M alaysia.

Single/ Multi Blade Fire Damper – Type: “ JFD” , for applications in Steel Bulkheads and Decks

FIRE DAM PER (STANDARD FIRE TEST)

IMO Res. MSC.61(67)-(FTP code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 15 December 2020

MED 1550256

Witt & Sohn A.G., Ziegeleiweg 38, 25421 Pinneberg, Germany.

Single Blade Fire Damper – Type: “ BK/ D/ A-60/ 200/ 4 to 1400/ 4/ Stel or VA/ pn” (Decks Only)

Fire Damper (Standard Fire Test) IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 5 December 2015

MED 1050310

Page 169: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.22 FIRE DAM PERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

169 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Witt & Sohn A.G. ...continued

Single Blade Fire Damper – Type: “ BK/ D/ A-60/ 200/ 200/ 5/ St/ el” (Decks Only)

Fire Damper (Standard Fire Test) IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 5 December 2015

MED 1050311

Multi Blade Fire Damper - Type: “ BK” Fire Damper (Standard Fire Test) IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 24 January 2017

MED 1250012/ M1

Single Bladed Circular Fire Damper – Type: “ IGW fire Damper, BK250, BK315 up to BK1800” , for use in A-Class Steel Decks

FIRE DAMPER (STANDARD FIRE TEST)

IMO Res.MSC.307(88) - 2010 FTP Code, Annex 1, Part 3

Expires: 9 November 2021

MED 1650273

Wozair Limited, 5 & 6 Saracen Close, Gillingham Business Park, Gillingham, Kent, M E8 0QN, United Kingdom (UK).

Single/ Multi Bladed Rectangular Fire Damper – Type: “ LFD”

Fire Damper (Standard Fire Test) IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 3 and IMO MSC/ Circ.1120. IMO Res. MSC.307(88) – (2010 FTP Code), Section 8.

Expires: 8 May 2020

MED 1550127/ M1

Single/ Multi Bladed Rectangular Fire Damper – Type: “ MFD”

Fire Damper (Standard Fire Test) IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 3 and IMO MSC/ Circ.1120. IMO Res. MSC.307(88) – (2010 FTP Code), Section 8.

Expires: 8 May 2010

USCG Module B number 164.139/ EC0038 MED 1050090/ M1

Page 170: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.25 'A' AND 'B' CLASS FIRE PROOF WINDOWS AND SIDE SCUTTLES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

170 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Constructiewerkplaats H.K. van Wingerden & Zonen B.V., Industrieweg 18, 4214KZ Vuren, Netherlands, The.

Fire Resisting Rectangular Window – Type: “ Wigo Fixed Window A-30”

A-30 Window (Standard Fire Test) IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 13 June 2017

MED 1250084

Fire Resisting Rectangular Window – Type: “ Wigo Fixed Window A-60”

A-60 Window (Standard Fire Test) IMO Fire Test Procedures Code, Annex 1, Part 3

Expires: 13 June 2017

MED 1250085

Fire Resisting Rectangular Window - Type: “ Wigo Fixed Window A-0ck”

A-0 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 7 May 2018

MED 1350073

Fire Resisting Rectangular Window – Type “ WIGO A-0”

A-0 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 27 January 2019

MED 1450016

Fire Resisting Rectangular Hinged Window – Type “ WIGO Hinged A-0”

A-0 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 27 January 2019

MED 1450017

Fire Resisting Circular Window – Type “ WIGO Fixed A0 Class Window and Scuttle”

A-0 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 4 June 2019

MED 1450125

Fire Resisting Window – Type: “ A-60 rectangular window with window box”

WINDOW (STANDARD FIRE TEST) IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO MSC.1/ Circ.1203 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 1 March 2020

MED 1550216

Page 171: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.25 'A' AND 'B' CLASS FIRE PROOF WINDOWS AND SIDE SCUTTLES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

171 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Deansteel M anufacturing Company, 111 M erchant Street, San Antonio, Texas 78204-1496, United States of America (USA).

Fire Resisting Window – Type “ DS WD A-60”

A-60 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 6 October 2015

MED 1050278

Het Anker BV, Kaatsbaan 10, 4209 AD Schelluinen, Netherlands, The.

Fire Resisting Rectangular Window – Type:“ A-0 1 Part Double Glazed Window”

A-0 Window (Standard Fire Test) IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3. IMO MSC/ Circ.1120

Expires: 20 May 2015

MED 1050119

InterDam Holding B.V, Waaldijk 135, 2988 AW Ridderkerk, Netherlands, The.

Fire Resisting Window – Type: “ IDM-WU-A60“ fire post blast window

A-60 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 20 March 2022

MED 1750051/ M1

Page 172: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.25 'A' AND 'B' CLASS FIRE PROOF WINDOWS AND SIDE SCUTTLES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

172 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jiangyin Huangshan M arine Fitting Co Ltd, No 28 Changshan Road, Chengjiang Street, Jiangyin City, 214400, China, People's Republic of.

Fire Resisting Window – Type: “ A-60 Class Window”

WINDOW A-60 (STANDARD FIRE TEST)

IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 3, IMO MSC/ Circ.1120 and MSC.1/ 1203.

Expires: 29 March 2017

MED 1250056

Fire Resisting Window – Type: “ A-60 Class Side Scuttle”

WINDOW A-60 (STANDARD FIRE TEST)

IMO Res. MSC.61(67) - (FTP Code) Annex 1, Part 3, IMO MSC/ Circ.1120 and MSC.1/ 1203.

Expires: 29 March 2017

MED 1250057

Fire Resisting Rectangular Window - Type: “ A-0 Class Fire Proof Window”

A-0 WINDOW IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 14 December 2018

MED 1450023

Fire Resisting Rectangular Window - Type: “ A-60 Class Fire Proof Window”

A-60 WINDOW IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 14 December 2018

MED 1450024

La Auxiliar Naval, Playabarri 7, 48950 Lutxana-Erandio, Vizcaya, Spain.

Fire Resisting Window – Type: “ Double Pane Rectangular Window” (Ref: 149946)

Window (A-60) (Standard Fire Test) IMO Resolution MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ. 1120 IMO MSC.1/ Circ. 1203

Expires: 2 August 2017

MED 1250195/ M1

Page 173: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.25 'A' AND 'B' CLASS FIRE PROOF WINDOWS AND SIDE SCUTTLES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

173 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Rectangular Window - Type: “ Double Pane Fire Resisting Window”

A-15 WINDOW IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 22 January 2019

MED 1450014

Fire Resisting Rectangular Window – Type “ Single Pane Rectangular Window”

A-60 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.61(67) – (FTP Code) Annex 1 Part 3 IMO MSC/ Circ. 1120 IMO MSC1/ Circ. 1203 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 24 January 2022

MED 1650274

Page 174: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.25 'A' AND 'B' CLASS FIRE PROOF WINDOWS AND SIDE SCUTTLES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

174 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

La Auxiliar Naval, S.A., Gabriel Aresti, 2, 48940 Leioa, Vizcaya, Spain.

Fire Resisting Rectangular Window – Type: “ A-0 Double Pane Fire Resisting Rectangular Window” w ith “ Pyroswiss 15” Glazing

A-0 Window (Standard Fire Test) IMO Res MSC. 61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 27 November 2017

MED 1250257

Fire Resisting Circular Window – Type: “ A-0 Double Pane Fire Resisting Circular Window” w ith Steel Mullion and “ Pyroswiss 15” Glazing

A-0 Window (Standard Fire Test) IMO Res. MSC. 61(67)-(FTP Code) Annex 1, Part 3. IMO MSC/ Circ 1120

Expires: 27 November 2017

MED 1250258

M etaalwarenfabriek & Kopergieterij "Het Anker" BV, Kaatsbaan 10, 4209 AD Schelluinen, Netherlands, The.

Fire Resisting Rectangular Window – Type: “ Het Anker A-30 Double Glazed Window”

A-30 WINDOW (STANDARD FIRE TEST)

IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 21 August 2017

MED 1250223

Fire Resisting Triple Pane Rectangular Window - Type: “ TST-A0-15”

A-0 WINDOW (STANDARD FIRE TEST)

IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 3 IMO MSC/ Circ.1120

Expires: 21 August 2017

MED 1250224

M M L M arine Ltd, 60 Waverley Street, Coatbridge, North Lanarkshire, M L5 2BE, Scotland, United Kingdom (UK).

Fire Resisting Window – Type: “ A-60 Window”

A-60 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ.1120 IMO Resolution A.754(18) Appendix A.1 – Window Hose Stream Test

Expires: 17 January 2016

MED 1150060/ M2

Officine Del Bello Srl, Via Nazario Sauro 15, 34076 Romans D'lsonzo (Goriza), I taly.

Fire Resisting Glazed Partition – Type: “ B-0”

NON LOAD BEARING GLAZED PARTITION (STANDARD FIRE TEST)

IMO Res. MSC.61(67) – FTP Code, Annex 1, Part 3 and MSC/ Circ.1120. IMO Res. MSC.307(88) – 2010 FTP Code, Section 8

Expires: 21 May 2018

MED 1450043

Page 175: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.25 'A' AND 'B' CLASS FIRE PROOF WINDOWS AND SIDE SCUTTLES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

175 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Glazed Partition – Type: “ B-15”

NON LOAD BEARING GLAZED PARTITION (STANDARD FIRE TEST

IMO Res. MSC.61(67) – FTP Code, Annex 1, Part 3 and MSC/ Circ.1120. IMO Res. MSC.307(88) – 2010 FTP Code, Section 8

Expires: 21 May 2018

MED 1450045/ M1

Principle Security Ltd, Unit 6, Old Fieldhouse Lane, Huddersfield, HD2 1AG, United Kingdom (UK).

Fire Resisting Glazed Partition System – Type: “ B-15 Class Glazed Panel System” fitted in a steel bulkhead.

B-15 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 16 January 2016

MED 1150012

Page 176: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.25 'A' AND 'B' CLASS FIRE PROOF WINDOWS AND SIDE SCUTTLES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

176 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Tianchang Ocean Ship Equipment Co Ltd, No. 1880, Tianye Road, Tianchang, Anhui, 239300, China, People's Republic of.

Fire Resisting Side Scuttle – Type “ TY-06-02”

A-60 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section

Expires: 16 March 2019

MED 1450132

Fire Resisting Rectangular Window – Type: “ TY-06-01”

A-60 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) – (2010 FTP Code) Section 8

Expires: 16 March 2019

MED 1450133

TILSE Industrie-und Schiffstechnik GmbH, Sottorfallee 12, 22529 Hamburg, Germany.

Fire Resisting Rectangular Window– Type: “ FORMGLAS SPEZIAL FR Interior (A-0 separating wall glazing)”

WINDOW (A-0) (STANDARD FIRE TEST)

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 3

Expires: 3 March 2021

MED 1650091

Fire Resisting Rectangular Window– Type: “ FORM GLAS SPEZIAL FR® Type 4”

WINDOW (A-60) (STANDARD FIRE TEST)

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 3

Expires: 20 March 2021

MED 1650096

Fire Resisting Rectangular Window– Type: “ FORM GLAS SPEZIAL FR® Type 7”

WINDOW (A-60) (STANDARD FIRE TEST)

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 3

Expires: 20 March 2021

MED 1650097

Trend M arine Products Limited, Catfield, Great Yarmouth, NR29 3BG, United Kingdom (UK).

Fire Resisting Rectangular Window – Type: “ 101-70”

Window (A-60) (Standard Fire Test) IMO Resolution MSC.61(67) – (FTP Code) Annex, 1, Part 3 IMO MSC/ Circ.1120 IMO MSC.1/ Circ.1203

Expires: 19 July 2015

MED 1050179

Page 177: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.25 'A' AND 'B' CLASS FIRE PROOF WINDOWS AND SIDE SCUTTLES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

177 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Van Dam BV, M arkweg zuid 1c, 4794 SN HEIJNINGEN, Netherlands, The.

Fire Resisting Rectangular Window – Type “ Van Dam A30 Window”

A-0 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.307(88) – (2010 FTP Code) Annex 1 Part 3

Expires: 25 September 2019

MED 1450198/ M2

Vetrotech Saint-Gobain International AG, Bernstrasse 43, 3175 Flamatt, Switzerland.

Fire Resisting Rectangular Window – Type “ PYROSWISS MONO 12mm”

A-0 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 4 August 2015

MED 1050194

Fire Resisting Side Scuttle – Type “ PYROSWISS MONO 12mm”

A-0 WINDOW (STANDARD FIRE TEST)

IMO Res. MSC.61 (67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 4 August 2015

MED 1050195

Page 178: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.25 'A' AND 'B' CLASS FIRE PROOF WINDOWS AND SIDE SCUTTLES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

178 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Vetrotech Saint-Gobain International AG ...continued

Fire Resisting Rectangular Window – Type: “ CONTRAFLAM LITE MARINE A-0 ISO”

A-0 Window (Standard Fire Test) IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 15 January 2018

MED 1350003

Z. P. Bohamet, UL Torunska 2, Ciele, 86-005 Biale Blota, Poland.

Fire Resisting Circular Window - Type: “ A-0 Class Sidescuttle“ according to manufacturer’s drawing No: BOH.9474-02, Rev.A

Window (A-0) (Standard Fire Test) IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 23 January 2017

MED 1250008

Fire Resisting Rectangular Window - Type: “ A-0 Class Window” according to manufacturer’s drawing No: BOH. 9474-01, Rev.A

Window (A-0) (Standard Fire Test) IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 IMO MSC/ Circ 1120

Expires: 23 January 2017

MED 1250009

Page 179: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.26a PENETRATIONS THROUGH 'A' CLASS DIVISIONS - ELECTRIC CABLE TRANSITS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

179 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

3M Fire Protection Products, 3M Center, Building 230-1D-31, St. Paul, M N 55144-1000, United States of America (USA).

Multiple Cable Penetration – Type: “ 3M Marine Fire Barrier System”

CABLE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.61(67)-(FTP Code) Annex 1, Part 3 IMO MSC/ Circ. 1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 18 August 2020

MED 1550235

HawkeTransitSystemSL, P.ETanosViernolesparcelaC9C10, 39300 Torrelavega (Santander), Spain.

Fire Resisting Circular Multi-Cable Penetration – Type: “ HRT” Series, for applications in steel bulkheads and decks

CABLE PENETRATION (STANDARD FIRE TEST)

IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 30 March 2022

MED 1550126/ M4

Fire Resisting Rectangular Multi-Cable Penetration – Type: “ HM” Series, for applications in steel bulkheads and decks.

Cable Penetration (Standard Fire Test) IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 21 June 2021

MED 1650157/ M1

IBM O, Lorentzstraat 13, 2665 JG Bleiswijk, Netherlands, The.

Single and Multi Cable Penetrations – Type: IBMO Multi Profile Systems” for Bulkheads and Decks

Cable Penetration (Standard Fire Test) IMO Res MSC 61(67)-(FTP Code) Annex 1, Part 3 IMO MSC Circ. 1120

Expires: 24 January 2018

USCG Module B number:

164.112/ EC0038

MED 1350011

Lucey LLc DBA Innovative M arine Inc, 3373 National Avenue, San Diego, California, 92113, United States of America (USA).

Fire Resisting Rectangular Multi-Cable Transits - Type: “ Dragon Fireshield Blanket and Sealant” , for applications in “ A” Class steel decks

Cable Penetration IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 12 February 2017

MED 1250014

Page 180: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.26a PENETRATIONS THROUGH 'A' CLASS DIVISIONS - ELECTRIC CABLE TRANSITS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

180 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fire Resisting Circular Multi-Cable Transits-Type: “ Dragon Fireshield Blanket and Sealant” , for applications in “ A” Class steel decks

Cable Penetration IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 12 February 2017

MED 1250015

M CT Brattberg AB, SE-371 92 Karlskrona, Sweden.

MCT Brattberg Type: “ RGS Cable Penetration seals” installed in Single/ Multiple rectangular MCT Brattberg Mild, Stainless Steel, Aluminium or Composite Frames

CABLE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8 IMO Res. MSC.307(88) – (2010 FTP Code), Annex 1, Part 3.

Expires: 9 June 2021

MED 1650148

Page 181: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.26a PENETRATIONS THROUGH 'A' CLASS DIVISIONS - ELECTRIC CABLE TRANSITS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

181 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M CT Brattberg AB ...continued

MCT Brattberg Single/ Multi Cable Circular Penetration seals Types: “ RGP” and “ RGPO” installed in MCT Brattberg Mild, Stainless Steel or Aluminium Circular frames Types: “ S, SFR, SFRB and SFRBO”

CABLE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 28 June 2021

MED 1650149

M CT Brattberg Ltd, Commerce Street, Carrs Industrial Estate, Haslingden, Lancashire, BB4 5JT, United Kingdom (UK).

MCT Brattberg BRATTFLEX Cable Penetration seals installed in Single/ Multiple rectangular MCT Brattberg Mild, Stainless Steel, A luminium or Composite Frames

CABLE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 12 February 2017

MED 1250016

MCT Brattberg M Series Deck and Bulkhead Glands for cables and SR & MSR Series Cable/ Pipe Penetrations.

CABLE /PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res.MSC.61(67)-(FTP Code), Annex 1, Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 22 February 2021

MED 1650147

Roxtec GmbH, Neuer Holtigbaum 1-3, 22143 Hamburg, Germany.

GK Packing-System, Modular and Rectangular Penetrations: Type "SPK/ SPR-EMC" (Steel or Aluminium Frame)

CABLE AND PIPE PENETRATION (STANDARD FIRE TEST)

IIMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88)-(2010 FTP Code), Section 8 IMO Res. MSC.307(88)-(2010 FTP Code) Annex 1, Part 3

Expires: 13 September 2019

MED 1450196/ M2

GK Packing-System, Modular and Circular Penetrations: Type "RM" (Steel or Aluminium Sleeve)

CABLE AND PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.61(67)-(FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88)-(2010 FTP Code), Section 8 IMO Res. MSC.307(88)-(2010 FTP Code) Annex 1, Part 3

Expires: 13 September 2019

MED 1450197/ M2

Page 182: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.26a PENETRATIONS THROUGH 'A' CLASS DIVISIONS - ELECTRIC CABLE TRANSITS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

182 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

SM Tech Co Ltd, 556-15 Daeyeon-dong, Nam-gu, Busan, 608-810, Korea, Republic of.

Fire Resisting Plastic Pipe Penetration System- Type: ‘SMT Fire Stop System 07’ for deck and bulkhead applications.

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 24 May 2017

MED 1250094

Taicang City Haisheng Shipping Fittings Co Ltd, Zhangjin, Hongqaio, Zhitang City, Jiangsu Province, China, People's Republic of.

Single and Multi Cable Penetrations – Type: ” CHS DL2007-A60/K(T)” Pouring-typed Cable Sealing Penetrations for Bulkheads and Decks

CABLE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.61(67) - (FTP Code), Annex 1, Part 3 MSC/ Circ. 1120 IMO Res. MSC.307(88) – (2010FTP Code) Section 8

Expires: 31 May 2020

MED 1650049

Page 183: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.26b PENETRATIONS THROUGH 'A' CLASS DIVISIONS - PIPE, DUCT, TRUNK ETC PENETRATIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

183 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Artech Rubber B.V., I jslandsestraat 8 - 12, NL-7202 CL Zutphen, Netherlands, The.

Pipe Penetration – Type: “ PSI FS Sealing Plugs” , for applications in steel divisions

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 11 October 2021

MED 1650197

FINCANTIERI, Cantieri Navali I taliani S.p.A., Via Genova, 1-34121, Trieste, I taly.

Single Metallic Pipe Penetration – Type: “ Fincantieri Flanged Penetration for Single Metallic (steel or cunifer) Pipe of Reduced Length” , for applications in A Class steel bulkheads and decks.

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.61 (67) - (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88) 2010 FTP Code, Section 8

Expires: 11 December 2018

MED 1350164

HawkeTransitSystemSL, P.ETanosViernolesparcelaC9C10, 39300 Torrelavega (Santander), Spain.

Fire Resisting Single or Multiple Pipe Rectangular Penetration – Type: “ HMX” Series, for applications in steel bulkheads and decks.

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res.MSC.307(88)-(2010 FTP Code), Annex 1, Part 3

Expires: 16 December 2019

MED 1550003/ M2

Fire Resisting Single or Multiple Pipe Circular Penetration – Type: “ HRT and HRST” Series, for applications in steel bulkheads and decks and aluminium decks.

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res.MSC.307(88)-(2010 FTP Code), Annex 1, Part 3

Expires: 16 December 2019

MED 1550004/ M2

Fire Resisting Single or Multiple Cable Circular Penetration – Type: “ HRT and HRST” Series.

CABLE PENETRATION (STANDARD FIRE TEST)

IMO Res.MSC.307(88)-(2010 FTP Code), Annex 1, Part 3

Expires: 12 January 2020

MED 1550010/ M2

Fire Resisting Single or Multiple Cable Rectangular Penetration – Type: “ HMX or HMCX” Series

CABLE PENETRATION (STANDARD FIRE TEST)

IMO Res.MSC.307(88)-(2010 FTP Code), Annex 1, Part 3

Expires: 12 January 2020

MED 1550011/ M4

Page 184: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.26b PENETRATIONS THROUGH 'A' CLASS DIVISIONS - PIPE, DUCT, TRUNK ETC PENETRATIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

184 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lorowerk K.H Vahlbrauk GmbH & Co. KG, Kriegerweg 1, 37581 Bad Gandersheim, Germany.

Fire Resisting Single Steel Pipe Penetration System – Type: “ LORO-X” for applications in steel bulkheads and decks

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.307(88)-(2010 FTP Code) Annex 1, Part 3

Expires: 17 October 2021

MED 1650256

Fire Resisting Single Steel Pipe Penetration System – Type: “ LORO-X” for applications in steel bulkheads and decks

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.307(88)-(2010 FTP Code) Annex 1, Part 3

Expires: 17 October 2021

MED 1650257

M CT Brattberg AB, Lyckeåborg, 371 92 Karlskrona, Sweden.

Single and Multiple Pipe Penetration – Type: “ MCT Brattberg 2000” RGP Mild Steel/ Stainless Steel Frames

Pipe Penetration IMO Res.MSC.61(67)-(FTP Code), Annex 1 Part 3 IMO MSC/ Circ.1120

Expires: 4 May 2017

USCG Module B number:

164.138/ EC0038

MED 1250096

Page 185: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.26b PENETRATIONS THROUGH 'A' CLASS DIVISIONS - PIPE, DUCT, TRUNK ETC PENETRATIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

185 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Raccorderie M etalliche S.p.A, Strada Sabbionetana, 59, 46010 - Campitello di M arcaria M N, I taly.

Single Metallic Pipe Penetration – Type: “ RM INOXPRESS” for applications in A- Class steel bulkheads and decks

IPE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.307(88) 2010 FTP Code, Annex 1, Part 3

Expires: 22 June 2021

MED 1650182

Single Metallic Pipe Penetration – Type: “ RM M ARINEPRES” for applications in A- Class steel bulkheads and decks

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.307(88) 2010 FTP Code, Annex 1, Part 3

Expires: 22 June 2021

MED 1650183

Single Metallic Pipe Penetration – Types: “ RM DRAIN F1, RM DRAIN M 1, RM DRAIN M 2, RM DRAIN M 3 and RM DRAIN M 4,” for applications in A-Class steel bulkheads and decks

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.307(88) 2010 FTP Code, Annex 1, Part 3

Expires: 22 June 2021

MED 1650184

Roxtec International AB, Rombvägen 2, Box 540, S-371 23 Karlskrona, Sweden.

Fire Resisting Plastic Pipe Penetration Seals – Type: “ Roxtec Sleev-it Pipe Penetration Seals” for A-60 Class Bulkheads and Decks

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) Section 8

Expires: 31 January 2021

MED 1650072/ M1

Rubber Design BV, Industrieweg 21, 2995 BE Heerjansdam, Netherlands, The.

Single Pipe Penetration – Type: “ Fiprotex” for applications in steel decks.

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Resolution MSC.61(67) – (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307 (88)-(2010 FTP Code) – Section 8

Expires: 29 August 2020

MED 1650144/ M1

Schwingungstechnik-Broneske GmbH, Ernst-Abbe-Strasse 9, 25451 Quickborn, Germany.

Single Steel Pipe Bulkhead Penetrations– Type: “ Flexible Fire-Watertight Penetration” For restricted applications in bulkheads only.

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 3

Expires: 18 August 2018

MED 1350112

Page 186: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.26b PENETRATIONS THROUGH 'A' CLASS DIVISIONS - PIPE, DUCT, TRUNK ETC PENETRATIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

186 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Single Pipe Deck Penetration – Type: “ Flexible Fire-Watertight Penetration”

PIPE PENETRATION (STANDARD FIRE TEST)

IMO Res. MSC.61(67) - Fire Test Procedures Code, Annex 1, Part 3, IMO MSC/ Circ.1120 IMO Res.MSC.307 (88) - (2010 FTP Code), Section 8

Expires: 23 September 2021

MED 1750014

Page 187: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.26b PENETRATIONS THROUGH 'A' CLASS DIVISIONS - PIPE, DUCT, TRUNK ETC PENETRATIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

187 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai Alafa M arine Equipment Co., Ltd, No. 880 Xinkai River Road, Xinhe Town, Chongming County, Shanghai, 202156, China, People's Republic of.

Single Pipe Penetration – Type: “ TMZ I, TMZ II and TMZ III”

PIPE PENETRATION (STANDARD FIRE TEST

IMO Fire Test Procedures Code, Annex 1, Part 3 IMO MSC/ Circ.1120. IMO Res. MSC.307(88) - (2010 FTP Code) – Section 8.3

Expires: 13 December 2020

MED 1650289

Page 188: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.27b PENETRATIONS THROUGH 'B' CLASS DIVISIONS - PIPE, DUCT, TRUNK, ETC PENETRATIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

188 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Evac Oy, Sinimäentie 14, FIN-02630 Espoo, Finland.

Pipe Penetration for B-15 Bulkheads – Type: “ B15 Back Plate, Evac Product No. 6543324 and 6545032”

Pipe Penetration (Standard Fire Test) IMO Res. MSC.61(67) – (FTP Code) Annex 1, Part 3 and Res. MSC.307 (88) 2010 (FTP Code) Section 8.

Expires: 22 January 2018

USCG Module B number:

164.138/ EC0038

MED 1350064/ M1

Sleev-it Fire Systems Ltd (Part of Roxtec International AB), Unit 21, Cloverlay Industrial Park, Canterbury Lane, Rainham, Kent, M E8 8GL, United Kingdom (UK).

Fire Resisting Plastic Pipe Penetration Seals – Type: “ Roxtec Sleev-it Penetration Seals” for applications in B-15 Class Bulkheads.

Pipe Penetration (Standard Fire Test) IMO Res. MSC.61 (67)- (FTP Code) Annex 1 Part 3 IMO MSC/ Circ.1120 IMO Res. MSC.307(88)-(2010 FTP Code) Section 8

Expires: 18 May 2021

MED 1650200

Page 189: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.28 SPRINKLER SYSTEM S (LIM ITED TO SPRINKLER HEADS) - (NOZZLES FOR FIXED SPRINKLER SYSTEM S, F

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

189 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Tyco Fire Products M anufacturing Limited, Stockport Trading Estate, Yew Street, Stockport, SK4 2JW, United Kingdom (UK).

Fixed Fire Extinguishing System Component – Types: “ TY-B & TY-FRB Sprinklers” with 5mm Glass Bulb or 3mm Quick Response Glass Bulb

SPRINKLER SYSTEM COM PONENT EN 12259-1 (1999) including A1 (2001), A2 (2004) and A3 (2006))

Expires: 5 April 2021

MED 1650133

Page 190: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.29 FIRE HOSES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

190 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Chhatariya Firetech Industries, 89, G.I .D.C Estate, M ahuva 364290, Dist. Bhavnagar Gujarat, India.

Type 1 Fire-fighting Hoses: - “ Magmex” , “ Infernex” and “ Aqualine” , of 38mm, 45mm and 50mm internal diameters.

FIRE HOSES WITH DIAM ETER ≤ 52mm

EN 14540 (2004) including A.1 (2007)

Expires: 16 September 2021

MED 1650285

Type 2 Fire-fighting Hoses: - “ Magmex Plus” , “ Infernex Plus” and “ Aqualine Plus” , of 38mm, 45mm and 50mm internal diameters.

FIRE HOSES WITH DIAM ETER ≤ 52mm

EN 14540 (2004) including A.1 (2007)

Expires: 16 September 2021

MED 1650287

Type 3 Fire-fighting Hoses: - “ Flexiline” , “ C-Jet” and “ Aqua-Jet” , of 38mm, 45mm and 50mm internal diameters.

FIRE HOSES WITH DIAM ETER ≤ 52mm

EN 14540 (2004) including A.1 (2007)

Expires: 16 September 2021

MED 1650288

Page 191: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

191 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Crowcon Detection Instruments Ltd, 172 Brook Drive, M ilton Park, Abingdon, Oxfordshire, OX14 4SD, United Kingdom (UK).

Triple Plus + A.1/ 3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPMENT Portable Oxygen and Flammable Gas Detection Unit

EN 60945 (2002) including IEC 60945 Corigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 60079-29-1(2007), EN 50104 (2010), EN 60079-0 (2009),

Expires: 20 May 2015

MED 1000014/ M4

EN 60079-1 (2007) including IEC 60079-1 Corrigendum 1 (2008), EN 60079-11 (2007)

GAS-PRO, TANK-PRO MULTI-GAS MONITOR

A.1/ 3.30 PORTABLE OXYGEN ANALYSIS & GAS DETECTION EQUIPMENT

EN 60945:2002 Including IEC 60945 Corrigendum 1: 2008 IEC 60092-504: 2001 Including IEC 60092-504 Corrigendum 1: 2011 IEC 60533: 1999

Expires: 9 June 2020

MED 1500009/ M2

Cat 2: (Explosive Gas Atmospheres) EN 50104: 2010, EN 60079-0: 2012 Inc A11:2013, EN60079-1: 2007 including IEC 60079-1Corrigendum 1:2008, EN 60079-10-1: 2009, EN 60079-11: 2012, EN 60079-29-1: 2007

Page 192: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

192 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPMENT T4

A.1/ 3.30 PORTABLE OXYGEN ANALYSIS & GAS DETECTION EQUIPMENT

EN 60945:2002 Including IEC 60945 Corrigendum 1: 2008, IEC 60092-504: 2001 Including IEC 60092-504 Corrigendum 1: 2011, IEC 60533: 1999. Cat 2: (Explosive Gas Atmospheres) EN 50104: 2010, EN 60079-29-1: 2007, EN 60079-0: 2012,

Expires: 13 October 2020

MED 1500019

EN60079-1: 2007 including IEC 60079-1Corrigendum 1:2008, EN 60079-10-1: 2009, EN 60079-11: 2012.

Gasman Oxygen C Gasman Oxygen Cr

A.1/ 3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPMENT Portable Oxygen Gas Detection Unit

EN 60945 (2002) including IEC 60945 Corigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 50104 (2010), EN 60079-0 (2012), EN 60079-1 (2007) including IEC 60079-1 Corrigendum 1 (2008), EN 60079-11 (2012)

Expires: 1 November 2019

MED 1500022

Page 193: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

193 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Crowcon Detection Instruments Ltd ...continued

Gasman Flammable C Gasman Flammable Cr

A.1/ 3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPMENT Portable Flammable Gas Detection Unit

EN 60945 (2002) including IEC 60945 Corigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 60079-29-1(2007), EN 60079-0 (2012), EN 60079-1 (2007) including IEC 60079-1 Corrigendum 1 (2008), EN 60079-11 (2012)

Expires: 1 November 2019

MED 1500025

Tetra 3 A.1/ 3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPMENT Portable Oxygen and Flammable Gas Detection Unit

EN 60945 (2002) including IEC 60945 Corigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 60079-29-1(2007), EN 50104 (2010), EN 60079-0 (2009), EN 60079-1 (2012) including IEC 60079-1 Corrigendum 1 (2008), EN 60079-11 (2012)

Expires: 1 November 2019

MED 1500027

Tetra A.1/ 3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPMENT Portable Oxygen and Flammable Gas Detection Unit

EN 60945 (2002) including IEC 60945 Corigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 60079-29-1(2007), EN 50104 (2010), EN 60079-0 (2012), EN 60079-1 (2007) including IEC 60079-1 Corrigendum 1 (2008), EN 60079-11 (2012)

Expires: 1 November 2019

MED 1500029

Page 194: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

194 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

UNITOR GAS-PRO UNITOR TANK-PRO MULTI-GAS MONITOR

A.1/ 3.30 PORTABLE OXYGEN ANALYSIS & GAS DETECTION EQUIPMENT

EN 60945:2002 Including IEC 60945 Corrigendum 1: 2008 IEC 60092-504: 2001 Including IEC 60092-504 Corrigendum 1: 2011 IEC 60533: 1999. Cat 2: (Explosive Gas Atmospheres) EN 50104: 2010 EN 60079-0: 2012 Inc. A11:2013,

Expires: 5 January 2021

MED 1600001/ M1

EN60079-1: 2007 including IEC 60079-1Corrigendum 1:2008 EN 60079-10-1: 2009, EN 60079-11: 2012 EN 60079-29-1: 2007

Page 195: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

195 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Crowcon Detection Instruments Ltd ...continued

PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPMENT UNITOR T4

A.1/ 3.30 PORTABLE OXYGEN ANALYSIS & GAS DETECTION EQUIPMENT

EN 60945:2002 Including IEC 60945 Corrigendum 1: 2008, IEC 60092-504: 2001 Including IEC 60092-504 Corrigendum 1: 2011, IEC 60533: 1999. Cat 2: (Explosive Gas Atmospheres) EN 50104: 2010, EN 60079-29-1: 2007, EN 60079-0: 2012, EN60079-1: 2007 including IEC 60079-1Corrigendum 1:2008, EN 60079-10-1: 2009, EN 60079-11: 2012.

Expires: 5 January 2021

MED 1600002

GAS M EASUREM ENT INSTRUM ENTS LTD, Inchinnan Business Park, Renfrew, Scotland, PA4 9RG, United Kingdom (UK).

Portable Gas Detector Type V!SA/ PS500 Software Version Ver.3.16

A.1/ 3.30 Portable Oxygen Analysis and Gas Detection Equipment

EN 60945 (2002) incl. IEC 600945 Corr. 1 (2008), IEC 60092-504 (2001) incl. IEC 60092-504 Corr.1 (2011), IEC 60533 (1999), EN 50104 (2010), EN 60079-29-1 (2007), EN 60079-0 (2011), EN 60079-1 (2007) incl. IEC 60079-1 Corr.1 (2008), EN 60079-11 (2012).

Expires: 27 August 2017

MED 0900002/ M4

Portable, flammable, toxic and oxygen gas detector Type: GASURVEYOR 500 SERIES OXYGAS 500 SERIES Software Version Ver.2.20

A.1/ 3.30 Portable Oxygen Analysis and Gas Detection Equipment

EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008) IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011) IEC 60533 (1999) EN 50104 (2010) EN 60079-29-1 (2007) EN 60079-0 (2009) EN 60079-1 (2007) including IEC 60079-1 Corrigendum 1 (2008) EN 60079-11 (2012)

Expires: 28 July 2015

MED 1050188/ M5

Page 196: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

196 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Intrinsically safe oxygen detector Type T.ex***/PS1/PS1***

IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 50104 (2010), EN 60079-0 (2011), EN 60079-11 (2007), EN 60079-26 (2007)

Expires: 12 December 2017

MED 1200009/ M5

Page 197: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

197 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

GAS M EASUREM ENT INSTRUM ENTS LTD ...continued

Portable Gas Detection Unit for the detection of Oxygen and Flammable Gas Type ShipSurveyor**/GS** Software Version Ver. 1.17

A.1/3.30 Portable Oxygen Analysis and Gas Detection Equipment

EN 60945:2002 incl. IEC 60945 Corr.1:2008 or IEC 60945(2002) including IEC 60945 Corrigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), EN 60079-29-1:2007, EN 60079-1:2007 incl. IEC 60079-1 Corr. 1:2008, IEC 60533 (1999), EN 50104 (2010), IEC 60079-0 (2011), EN 60079-11 (2012).

Expires: 28 January 2019

MED 1300015/ M3

Portable Gas Detector PS 200 Series IEC60945(2002) including IEC 60945 Corrigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 50104 (2010),EN 60079-0(2012) including A11 (2013),EN60079-11 (2012),EN60079-1 (2007) Including IEC 60079-1 Corrigendum 1 (2008),EN60079-29-1 (2007)

Expires: 20 January 2020

MED 1600010

M artek M arine Ltd., Unit 6A Adwick Park, Rotherham, South Yorkshire, S63 5AB, United Kingdom (UK).

Portable Gas Detector Type: Marine 4 Software Version 1.22

IEC 60945(2002) including IEC 60945 Corrigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 50104 (2010), EN 60079-0 (2012), EN 60079-11 (2012), EN 60079-1 (2007) incl IEC 60079-1 Corr. 1 (2008), EN 60079-29-1 2007).

Expires: 24 November 2016 The following MED specified standards are not applicable to this product:- EN 60079-10-1(2005) EN 60079-15(2010) EN 60079-26 (2007)

MED 1300005/ M2

Page 198: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

198 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Portable Gas Detector Type: Marine Tankscape Software Version 1.17

EN 60945:2002 incl IEC 60945 Corr.1:2008 or IEC 60945(2002) incl IEC 60945 Corr 1 (2008), IEC 60092-504(2001) incl IEC 60092-504 Corr 1(2011), EN 60092-29-1:2007, EN 60079-1:2007 incl. IEC 60079-1 Corr. 1:2008, IEC 60533 (1999), EN 50104(2010), IEC 60079-0(2012), EN 60079-11 (2012).

Expires: 28 January 2019 The following MED specified standards are not applicable to this product:- EN 60079-10-1(2005) EN 60079-15(2010) EN 60079-26 (2007)

MED 1300006/ M2

Wilhelmsen Ships Services, Strandveien 20, 1366 Lysaker, Norway.

Tank-Mate A.1/ 3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPMENT Portable Oxygen and Flammable Gas Detection Unit

EN 60945 (2002) including IEC 60945 Corigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 60079-29-1(2007),

Expires: 20 May 2015

MED 1000013/ M2

Page 199: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

199 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wilhelmsen Ships Services ...continued

EN 50104 (2010), EN 60079-0 (2009), EN 60079-1 (2007) including IEC 60079-1 Corrigendum 1 (2008), EN 60079-11 (2007)

MED 1000013/ M2

Oxy-Mate C Oxy-Mate Cr Software Ver. V1i1.22

A.1/ 3.30 Portable Oxygen Analysis and Gas Detection Equipment Portable Oxygen Gas Detection Unit

EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 50104 (2010), EN 60079-0 (2012), EN 60079-1 (2007) including IEC 60079-1 Corrigendum 1 (2008), EN 60079-11 (2012).

Expires: 1 November 2019

MED 1500023

Combi-Mate 3 Software Ver. V1 i1.11

A.1/ 3.30 Portable Oxygen Analysis and Gas Detection Equipment Portable Oxygen and Flammable Gas Detection Unit

EN 60945 (2002) including IEC 60945 Corigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999),

Expires: 1 November 2019

MED 1500024

EN 60079-29-1(2007), EN 50104 (2010), EN 60079-0 (2009), EN 60079-1 (2012) including IEC 60079-1 Corrigendum 1 (2008), EN 60079-11 (2011).

Page 200: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

200 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Gas-Mate C Gas-Mate Cr Software Ver. V1i1.22

A.1/ 3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPMENT Portable Flammable Gas Detection Unit

EN 60945 (2002) including IEC 60945 Corigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 60079-29-1(2007), EN 60079-0 (2012), EN 60079-1 (2007) including IEC 60079-1 Corrigendum 1 (2008), EN 60079-11 (2012)

Expires: 1 November 2019

MED 1500026

Page 201: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.30 PORTABLE OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

201 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wilhelmsen Ships Services ...continued

Combi-Mate Software Ver. V1 i1.15

A.1/ 3.30 Portable Oxygen Analysis and Gas Detection Equipment Portable Oxygen and Flammable Gas Detection Unit

EN 60945 (2002) including IEC 60945 Corigendum 1 (2008), IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999), EN 60079-29-1(2007), EN 50104 (2010), EN 60079-0 (2012), EN 60079-1 (2007) including IEC 60079-1 Corrigendum 1 (2008), EN 60079-11 (2012)

Expires: 1 November 2019

MED 1500028

Page 202: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.32 FIRE RESTRICTING M ATERIALS (EXCEPT FURNITURE) FOR HIGH SPEED CRAFT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

202 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Evonik Foams, Inc, 800 N. Watters Rd. Suite 190, Allen, Texas, United States of America (USA).

Fire Resisting Material – Type: “ SOLIMIDE TA-301” Insulation Foam

FIRE RESISTING M ATERIAL (EXCEPT FURNITURE) FOR HIGH SPEED CRAFT

IMO Resolutions MSC.40(64) and MSC.90(71)

Expires: 28 November 2017

MED 1250247

Page 203: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.34 FIRE RESTRICTING DIVISIONS FOR HIGH SPEED CRAFT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

203 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Unifrax Limited, M ill Lane, Rainford, St. Helens, M erseyside, WA11 8LP, United Kingdom (UK).

Fire Resisting Load Bearing Aluminium Deck Insulated on the Under Side with Type: “ Load Bearing Fire-Resisting Deck 60” system for High-Speed Craft, using “ FyreWrap LT” AES wool insulation

LOAD BEARING FIRE-RESISTING DECK 60

IMO Resolution MSC.45(65) and Res.MSC.61(67) – FTP Code, Part 11, 2000 Amendments in Res.MSC.101(73). MSC/ Circ.1120. IMO Res.MSC.307(88) - 2010 FTP Code, under Section 8

Expires: 18 June 2018

MED 1350143

Fire Resisting Non Load Bearing Aluminium Deck Insulated on the Under Side with Type: “ Non-Load Bearing Fire-Resisting Deck 30” system for High-Speed Craft, using “ FyreWrap LT” AES wool insulation

NON-LOAD BEARING FIRE-RESISTING DECK 30

IMO Resolution MSC.45 (65) and Res.MSC.61 (67) – FTP Code, Part 11, 2000 Amendments in Res.MSC.101 (73). MSC/ Circ.1120. IMO Res.MSC.307(88) - 2010 FTP Code, under Section 8

Expires: 24 October 2018

MED 1350157

Fire Resisting Non-Load Bearing Aluminium Bulkhead Insulated on the Fire Exposed Side with Type: “ Non-Load Bearing Fire-Resisting Bulkhead 30” system for High-Speed Craft using “ FyreWrap LT” AES wool insulation

NON-LOAD BEARING FIRE-RESISTING BULKHEAD 30

IMO Resolution MSC.45 (65) and Res.MSC.61 (67) – FTP Code, Part 11, 2000 Amendments in Res.MSC.101 (73). MSC/ Circ.1120. IMO Res.MSC.307(88) - 2010 FTP Code, under Section 8

Expires: 24 October 2018

MED 1350158

Page 204: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.35 FIRE DOORS ON HIGH-SPEED CRAFT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

204 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M arine Systems Technology Ltd, Unit F, Nantwich Road, M iddlewich, Cheshire, CW10 0LH, United Kingdom (UK).

Fire Doors on High Speed Craft – Type: “ MST 60 Minute Door for HSC Code” or “ A-60 Door for SOLAS, Chapter II-2”

A-60 DOOR SINGLE LEAF HINGED IMO Res. MSC.307(88) 2010 (FTP Code) Annex 1, Part 3

Expires: 9 May 2018

MED 1350061

Page 205: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.39 NOZZLES FOR EQUIVALENT WATER M IST FIRE EXTINGUISHING SYSTEM S FOR M ACHINERY SPACES AND CA

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

205 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Ultra Fog AB, Backa Strandgata 18, Hisings Backa, 422 46, Sweden.

Fixed Fire Extinguishing System – Type: “ Ultra Fog” System for Machinery Spaces of Category A and Cargo Pump Rooms with a deckhead height not exceeding 10.1 metres and maximum enclosure volume of 3348m3, equivalent to SOLAS II-2/ 10.4 & FSS Code, Chapter 7-2-2.

PRESSURE WATER-SPRAYING SYSTEM

IMO MSC/ Circ. 1165 as amended by MSC.1/ Circ 1269 and MSC.1/ Circ.1386

Expires: 11 August 2019

MED 1450249/ M1

Fixed Fire Extinguishing System – Type: “ Ultra Fog” System for Machinery Spaces of Category A and Cargo Pump Rooms with a deckhead height not exceeding 5 metres and maximum enclosure volume of 500 m3, equivalent to SOLAS II-2/ 10.4 & FSS Code, Chapter 7-2.2

PRESSURE WATER-SPRAYING SYSTEM

IMO MSC/ Circ. 1165 as amended by MSC.1/ Circ 1269 and MSC.1/ Circ.1386

Expires: 10 October 2021

MED 1650254

Page 206: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.40 LOW-LOCATION LIGHTING SYSTEM S (COM PONENTS ONLY)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

206 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

ANRO Firma Poligraficzno - Handlowa, Ul. Siewierska 196c, 42-431 Zawiercie, Poland.

Photoluminescent Fire Safety Signs – Type: “ RS-1B/ AL” aluminium panels

LOW LOCATION LIGHTING SYSTEM S (Components Only)

IMO Resolution A.752(18) ISO 15370 : 2001 Annex A – Testing of photoluminescent materials. IMO Resolution MSC.307(88), Annex 1, Part 2 and Part 5

Expires: 18 December 2016

MED 1450266

Jessup M anufacturing Company, P.O. Box 366, 2815 West State Route 120, M cHenry, IL 60050, United States of America (USA).

Photoluminescent thin gauge polyester film – Types: “ 7500 series Glo Brite® and 7600 Glo Brite® series (limited between 7615 and 7650)

PHOTOLUM INESCENT M ATERIALS

IMO Resolution A.752(18) Expires: 4 October 2020

MED 1550230/ M1

M aritime Progress, Sealand Centre, 3-5 Holmethorpe Avenue, Redhill, Surrey, RH1 2LZ, United Kingdom (UK).

Photoluminescent Low Location Lighting Panels – Types: ” Telglow Photoluminescent Self-adhesive Flexible Vinyl Film” , “ Telglow photoluminescent Rigid Board” and “ Telglow photoluminescent C Rigid Board”

Low Location Lighting Systems (Components Only)

IMO Resolution A.752 (18) Expires: 1 December 2021

MED 1650286

Sakerhetspartner Norden AB, Bryggargatan 35, Umea, S-904 33, Sweden.

Low Location Lighting Panel Type U1000

Aluminium Photoluminescent Low Location Lighting Panels

IMO Resolution A752(18) ISO 15370(2001)

Expires: 22 February 2015

MED 1000005

Page 207: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.40 LOW-LOCATION LIGHTING SYSTEM S (COM PONENTS ONLY)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

207 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Way Out Evacuation Systems, 3/30 Bay Road, Sandringham, VICTORIA 3191, Australia.

Photoluminescent Fire Safety Signs – Type: “ Lumink” aluminium panels

LOW LOCATION LIGHTING SYSTEM S (Components Only)

IMO Resolution A.752(18) ISO 15370: 2010 Annex A – Testing of photoluminescent materials. IMO Resolution MSC.307(88) - (2010 FTP Code), Annex 1, Part 5 and Annex 2.2

Expires: 11 June 2020

MED 1550143/ M1

Page 208: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.41 EM ERGENCY ESCAPE BREATHING DEVICES (EEBD)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

208 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Draeger Safety (UK) Limited, Ullswater Close, Blyth, Northumberland, NE24 4RG, United Kingdom (UK).

Emergency Escape Breathing Apparatus – Type: “ Dräger Saver CF(10), Saver CF(15) and Saver CF(15)CC”

SELF CONTAINED BREATHING APPARATUS FOR EM ERGENCY ESCAPE PURPOSES

European Standard EN 1146 (2005) ISO 23269-1 (2008)

Expires: 12 February 2019

MED 1450032

Emergency Escape Breathing Apparatus – Type: “ Dräger Saver PP(10), Saver PP(15) and Saver PPM(15)”

SELF CONTAINED BREATHING APPARATUS FOR EM ERGENCY ESCAPE PURPOSES

European Standard EN 402 (2003) ISO 23269-1 (2008)

Expires: 12 February 2019

MED 1450033/ M1

Jiangsu Huayan M arine Equipment Co. Ltd, No. 8 Huangjintang West Road, Danyang Economic Development Zone, Jiangsu, China, People's Republic of.

Emergency Escape Breathing Apparatus – Type: “ TH15D”

SELF CONTAINED BREATHING APPARATUS FOR EMERGENCY ESCAPE PURPOSES

ISO 23269-1 (2008) European Standard EN 1146(2005)

Expires: 2 March 2022

MED 1750039

Emergency Escape Breathing Apparatus – Type: “ TH15F”

SELF CONTAINED BREATHING APPARATUS FOR EM ERGENCY ESCAPE PURPOSES

ISO 23269-1 (2008) European Standard EN 1146(2005)

Expires: 2 March 2022

MED 1750040

Page 209: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.42 INERT GAS SYSTEM S COM PONENTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

209 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Kashiwa Co Ltd, 1165-9 Kutsukake, Bandoh-SHI, Ibaraki-pref, 306-0515, Japan.

Secondary blower for inert gas generator: TBMS series

Inert gas system components to deliver the combustion gas to the inert gas generator, and then the as scrubbed combustion gas to the cargo tanks: Gas capacity (m3/ hr): 5350 Discharge pressure (kPa): 14.7

IMO MSC/ Circs.485, 450/ Rev. 1, 387 and 353 IMO Resolution A.567(14)

Expires: 12 September 2017

MED 1200013

Inert gas system components to deliver the scrubbed flue gas to the cargo tanks.

Inert gas blower, types IGB, KIGBM & KIGB series

SOLAS 74 as amended, Reg. II-2/ 4 IMO Resolution MSC.98(73)- FSS Code 15 IMO Resolution A.567(14) IMO MSC/ Circ.353, 485, 731 and 1120

Expires: 18 January 2022

MED 1700001/ M1

Inert gas system components to cool the flue gas and remove most of the sulphur dioxide and particulate soot.

Inert gas scrubber, types: KSC-050, KSC-095, KSC-135, KSC-185, KSC-240 & KSC-285

SOLAS 74, as amended, Reg. II-2/ 4, FSS Code 15, IMO Resolution A.567(14), IMO MSC/ Circ.353, 485, and 1120

Expires: 18 January 2022

MED 1700002

Inert gas system components to automatically prevent the back flow of cargo gas even when the inert gas plant is shut down

Deck water seal, types: KDW-065, KDW-090, KDW-105A, KDW-120, KDW-170, KDW-170A, KDW-205, KDW-230 & KDW-250

SOLAS 74, as amended, Reg. II-2/ 4, FSS Code 15, IMO Resolution A.567(14), IMO MSC/ Circ.353, 485, and 1120

Expires: 18 January 2022

MED 1700003

Page 210: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.42 INERT GAS SYSTEM S COM PONENTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

210 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

NOXERIOR SRL, Via Giordania 48, 58100 Grosseto, I taly.

Nitrogen Membrane Separators

Marine Nitrogen Membrane Separators NITROMEM types NM-09/ NM-18/ NM-27/ NM-36. N 2 capacity/ O2 residual content from 5Nm3/ hr at 0.5% to 175Nm3/ hr at 5%. The performance of the separators is dependent on the air compressor and quality of air supplied to the unit. See manufacturer’s data sheets for details.

For installation in ships machinery spaces in acc. w ith the I.M.O. FSS Code. Complies w ith: SOLAS 74 as amended. I.M.O. Res.A567(14). MSC98(37)-(FSS Code)15, M.S.C. Circ. 353,485,731,1120.

Expires: 4 April 2021 See certificate for other conditions and Design Appraisal Document for Approval Conditions. This approval does not include the upstream compressors and equipment or downstream control and safety devices.

MED 1600007

Page 211: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.42 INERT GAS SYSTEM S COM PONENTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

211 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

NOXERIOR SRL ...continued

Nitrogen Membrane Separators

Marine Nitrogen Membrane Separators NITROMEM types NM-45/ NM-54/ NM-63/ NM-72. N 2 capacity/ O2 residual content from 24.8 Nm3/ hr at 0.5% to 350Nm3/ hr at 5%. The performance of the separators is dependent on the air compressor and quality of air supplied to the unit. See manufacturer’s data sheets for details.

For installation in ships machinery spaces in acc. w ith the I.M.O. FSS code. Complies w ith: SOLAS 74 as amended. I.M.O. Res.A567(14). MSC98(37)-(FSS code)15, M.S.C. Circ. 353,485,731,1120.

Expires: 4 April 2021 See certificate for other conditions and Design Appraisal Document for Approval Conditions. This approval does not include the upstream compressors and equipment or downstream control and safety devices.

MED 1600008

Page 212: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.43 NOZZLES FOR DEEP FAT COOKING EQUIPM ENT FIRE EXTINGUISHING SYSTEM (AUTOM ATIC OR M ANUAL TY

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

212 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Samjoo Engineering Co. Ltd., #1508-3, Dadae-Dong, Saha-Gu, Pusan 604-050, Korea, Republic of.

Fixed Fire Extinguishing System – Type: “ Ansul R-102 Fixed Extinguishing System for Deep Fat Fryers”

FIXED EXTINGUISHING SYSTEM FOR PROTECTION OF DEEP FAT COOKING EQUIPM ENT

ISO 15371 : 2009 SOLAS Amendments 2000, Chapter II-2, Regulation 10.6.4.1

Expires: 18 November 2018

MED 1350175/ M1

Tyco Safety Products, 1 Stanton Street, M arinette, Wisconsin, 54143-2542, United States of America (USA).

Fixed Fire Extinguishing System – Type: “ Ansul R-102 Fixed Extinguishing System for Deep Fat Fryers”

Fixed Extinguishing System for Protection of Deep Fat Cooking Equipment

ISO 15371 : 2000 and MSC.1/ Circ. 1433. SOLAS Amendments 2000, Chapter II-2, Regulation 10.6.4.1

Expires: 9 December 2017

MED 1250261

Ultra Fog AB, Backa Strandgata 18, Hisings Backa, 422 46, Sweden.

Fixed Fire Extinguishing System – Type: “ ULTRAFOG FAT FRYER SYSTEM” Pressurised Cylinder or Pumped Water Supply Fixed Fire Extinguishing System for Deep Fat Fryers”

FIXED EXTINGUISHING SYSTEM FOR PROTECTION OF DEEP FAT COOKING EQUIPM ENT

ISO 15371:2009 SOLAS 1974, Chapter II-2, Regulation 10.6.4

Expires: 5 February 2017

MED 1550206

Page 213: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.45 EQUIVALENT FIXED GAS FIRE EXTINGUISHING SYSTEM S COM PONENTS (EXTINGUISHING M EDUIM ,HEAD VALV

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

213 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Hygood, Burlington House, Hewett Road, Gapton Hall Industrial Estate, Great Yarmouth, Norfolk, NR31 0NN, United Kingdom (UK).

Fixed Fire Extinguishing System – Type: “ FM200 Total Flooding Systems – Marine” For Machinery Spaces of Category A and Cargo Pump Rooms Equivalent to Fire Extinguishing Systems Required by SOLAS 1974, as amended, Chapter II-2/ 10.5 and 10.9

Fixed Gas Fire Extinguishing System IMO MSC/ Circular 848 as amended by MSC.1/ Circ.1267 and IMO MSC.1/ Circ. 1316

Expires: 12 September 2016

MED 1150258/ M4

Fixed Fire Extinguishing System – Type: “ FM200 Total Flooding Systems – Marine” For Machinery Spaces of Category A and Cargo Pump Rooms Equivalent to Fire Extinguishing Systems Required by SOLAS 1974 as amended, Chapter II-2/ 10.5 and 10.9

Fixed Gas Fire Extinguishing System IMO MSC/ Circular 848 as amended by MSC.1/ Circ.1267 and IMO MSC.1/ Circ. 1316

Expires: 12 September 2021

MED 1650172/ M1

Kidde - Fenwal Inc., 400 M ain Street, Ashland, M A 01721, United States of America (USA).

Fixed Gas Fire Extinguishing System – Type: “ FM-200 ECS Marine Fire Suppression System” for Machinery Spaces of Category A and Cargo Pump Rooms equivalent to fire extinguishing systems required by SOLAS 1974 as amended, Chapter II-2/ 10.4 and 10.9

FIXED GAS FIRE EXTINGUISHING SYSTEM

IMO MSC/ Circ. 848 as amended by MSC.1/ Circ.1267

Expires: 14 January 2019

MED 1450158

Kidde Fire Protection, 1st Floor Stokenchurch House, Oxford Road, Stokenchurch, High Wycombe, Buckinghamshire, HP14 3SX, United Kingdom (UK).

Fixed Fire Extinguishing System – Type: “ FM-200 GX20 Series Engineered Fire Suppression System” for Machinery Spaces of Category A and Cargo Pump Rooms equivalent to fire-extinguishing systems required by SOLAS 1974 as amended, Chapter II-2/ 10.5 and 10.9

Fixed Gas Fire Extinguishing System IMO MSC/ Circ. 848 as Amended by MSC.1/ Circ.1267

Expires: 13 October 2018

MED 1350173/ M1

Page 214: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.45 EQUIVALENT FIXED GAS FIRE EXTINGUISHING SYSTEM S COM PONENTS (EXTINGUISHING M EDUIM ,HEAD VALV

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

214 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M arinefire s.r.l., Via Grecale 33, 55049 Viareggio (LU), I taly.

Fire Extinguishing System – Type: “ NOVEC 1230 Marine MFN Series Engineered Fire Suppression System” for Machinery Spaces of Category A and Cargo Pump Rooms equivalent to Fire Extinguishing Systems required by SOLAS 1974 as amended, Chapter II-2/ 10.5 and 10.9

FIXED GAS FIRE EXTINGUISHING SYSTEM

IMO MSC/ Circ. 848 as amended by MSC.1/ Circ.1267 and IMO MSC.1/ Circ. 1316

Expires: 17 April 2021

MED 1650240

Page 215: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.45 EQUIVALENT FIXED GAS FIRE EXTINGUISHING SYSTEM S COM PONENTS (EXTINGUISHING M EDUIM ,HEAD VALV

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

215 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M arinefire s.r.l. ...continued Fixed Fire Extinguishing System – Type: “ FM-200 Marine MFE Series Engineered Fire Suppression System” for Machinery Spaces of Category A and Cargo Pump Rooms equivalent to Fire Extinguishing Systems Required by SOLAS 1974 as amended Chapter II-2/ 10.5 and 10.9

FIXED GAS FIRE EXTINGUISHING SYSTEM

IMO MSC/ Circ. 848 as amended by MSC.1/ Circ.1267 and IMO MSC.1/ Circ. 1316

Expires: 17 April 2021

MED 1650241

M etalcraft, Inc, Sea-Fire M arine Division, 9331A Philadelphia Road, Baltimore, M D 21237, United States of America (USA).

Fixed Fire Extinguishing System – Type: “ H-Series Engineered FM-200 System” for Machinery Spaces of Category A and Cargo Pump Rooms equivalent to fire-extinguishing systems required by SOLAS 1974 as amended, Chapter II-2/ 10.5 and 10.9

Fixed Gas Fire Extinguishing System IMO MSC/ Circular 848 as amended by MSC.1/ 1267

Expires: 9 June 2014

MED 0950386

Tyco Fire & Integrated Solutions, Tyco Park, Grimshaw Lane, Newton Heath, M anchester, M 40 2WL, United Kingdom (UK).

Single stage pressure reduction fixed gas fire extinguishing system – Type: “ INERGEN 300 bar Marine Gaseous Fire Extinguishing System” for Machinery Spaces of Category A and Cargo Pump Rooms equivalent to fire extinguishing systems required by SOLAS 1974 as amended, Chapter II-2/ 10.4 and 10.9

FIXED GAS FIRE EXTINGUISHING SYSTEM

IMO MSC/ Circ. 848 as amended by MSC/ Circ. 1267 and IMO MSC.1/ Circ. 1316.

Expires: 4 January 2021

MED 1650173/ M1

Page 216: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.45 EQUIVALENT FIXED GAS FIRE EXTINGUISHING SYSTEM S COM PONENTS (EXTINGUISHING M EDUIM ,HEAD VALV

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

216 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Tyco Safety Products, Burlington House, Hewett Road, Gapton Hall Industrial Estate, Great Yarmouth, Norfolk, NR31 0NN, United Kingdom (UK).

Fixed Gas Fire Extinguishing System – Type: “ Sapphire Total Flood Fire Suppression 25 bar and 42 bar Systems” for Machinery Spaces of Category A and Cargo Pump Rooms equivalent to fire-extinguishing systems required by SOLAS 1974 as amended, Chapter II-2/ 10.5 and 10.9. In addition the system may be used in the cargo compressor and pump rooms of LNG and LPG carriers.”

FIXED GAS FIRE EXTINGUISHING SYSTEM

IMO MSC/ Circular 848 as amended by MSC.1/ Circ.1267 and IMO MSC.1/ Circ. 1316

Expires: 1 June 2021

MED 1650170/ M2

Page 217: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.47 CONCENTRATE FOR FIXED HIGH EXPANSION FOAM FIRE EXTINGUISHING SYSTEM S FOR M ACHINERY SPACE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

217 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Dafo Fomtec AB, P.O. Box 683, SE - 135 26 Tyresö, Sweden.

Fire Extinguishing Low Expansion Foam Concentrate – Types: “ AFFF 1% F, 3% & 6% Synthetic Foam Concentrate’’

FOAM CONCENTRATE IMO MSC.1/ Circular 1312 Expires: 9 December 2017

MED 1250252/ M3

Fire Extinguishing Low Expansion Foam Concentrate – Types: “ P3% & P6% Protein Foam Concentrate’’

FOAM CONCENTRATE IMO MSC.1/ Circular 1312 Expires: 9 December 2017

MED 1250253/ M2

Fire Extinguishing Low Expansion Foam Concentrate – Types: “ Fomtec AFFF 3% Ultra LT” Synthetic Foam Concentrate’’.

FOAM CONCENTRATE IMO MSC.1/ Circular 1312 Expires: 26 March 2019

MED 1450073

Dafo Fomtec AB, Vindkraftsvagen 8, 13570 Stockholm, Sweden.

Fire Extinguishing Low Expansion Foam Concentrate: ‘Fomtec FFFP 3%’ Type ‘B’ Protein Foam Concentrate.

FOAM CONCENTRATE IMO MSC.1/ Circular 1312 IMO MSC.1/ Circular 1312/ Corrigendum 1.

Expires: 20 April 2021

MED 1650134

Fire Extinguishing Low Expansion Foam Concentrate: ‘Fomtec ARC Miljö 3x3’ Type ‘A’ Synthetic Foam Concentrate.

FOAM CONCENTRATE IMO MSC.1/ Circular 1312 IMO MSC.1/ Circular 1312/ Corrigendum 1.

Expires: 20 April 2021

MED 1650135

Dafo Fomtec AB, Garnisonsgatan 47A, 254 66 Helsingborg, Sweden, Sweden.

Fomtec® FP 3% AR" Protein-Based Alcohol Resistant Firefighting Foam

FOAM CONCENTRATE IMO MSC.1/ Circ. 1312 and MSC.1/ Circ. 1312/ Corr.1

Expires: 22 February 2022

MED 1750024/ M1

Page 218: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.47 CONCENTRATE FOR FIXED HIGH EXPANSION FOAM FIRE EXTINGUISHING SYSTEM S FOR M ACHINERY SPACE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

218 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Intergrated Fire Protection PVT Ltd, 60A Pandir M adan M ohan M alabya Sarani, Chakraberia Road North, Kolkata 700 020, India.

Fire Extinguishing High Expansion Foam Concentrate – Type: “ IFP-Unifoam” Synthetic Foam Concentrate (3%)

Foam Concentrate IMO MSC/ Circular.670 Expires: 23 August 2016

MED 1150240

Page 219: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.48 FIXED WATER BASED LOCAL APPLICATION FIRE FIGHTING SYSTEM S COM PONENTS FOR USE IN CATEGORY

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

219 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Firecon Group Oy, Otto Korhosen katu 1, 20660 Littoinen, Finland.

Fixed Local Application Fire Extinguishing System- Type: “ SoftEx LAFFS with pumped or hydrophore tank water supply”

FIXED LOCAL APPLICATION FIRE-FIGHTING SYSTEM

IMO MSC.1/ Circular 1387 which supersedes IMO MSC/ Circular 913

Expires: 26 June 2021

MED 1650243

Imtech Deutschland GmbH & Co. KG Schiffbau-/Dockbautechnik, Hammer Straße 32, D-22041 Hamburg, Germany.

Fixed Local Application Fire Extinguishing System – Type: “ M5” nozzles

FIXED LOCAL APPLICATION FIRE-FIGHTING SYSTEM

IMO MSC/ Circular 913, as amended by MSC.1/ Circ.1387

Expires: 6 February 2022

MED 1750010

Knaack & Jahn Schiffbau GmbH, Uffelnsweg 10, 20539 Hamburg, Germany.

Fixed Local Application Fire Extinguishing System – Type: “ Water mist nozzle MK-6”

Fixed Local Application Fire-Fighting System

IMO MSC.1/ Circ. 1387 superseding MSC.1/ Circ. 913 (and superseding IMO MSC.1/ Circ.1276)

Expires: 10 October 2016

MED 1150270

Shanghai Aohan M arine Company, Room 21H, 428 Tianmuzhong Road, Shanghai, 200071, China, People's Republic of.

IMO MSC.1/ Circ. 1387 IMO MSC.1/ Circ. 1387 IMO MSC.1/ Circ. 1387 Expires: 7 November 2019

MED 1550063

Page 220: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.48 FIXED WATER BASED LOCAL APPLICATION FIRE FIGHTING SYSTEM S COM PONENTS FOR USE IN CATEGORY

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

220 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai Rongde Engineering Equipment Co., Ltd, Room 1401, No. 1, Lane 1695, Pudong Avenue, Shanghai, 200135, China, People's Republic of.

Fixed Local Application Fire Extinguishing System Type: “ RDFF” Watermist Local Application Fire Fighting System in Machinery Spaces of Category A

Fixed Local Application Fire-Fighting System

IMO MSC/ Circular 913 and MSC.1/ Circ.1276, as amended by MSC.1/ Circ.1387

Expires: 30 January 2018

MED 1350038

Ultra Fog AB, Backa Strandgata 18, Hisings Backa, 422 46, Sweden.

Fixed Local Application Fire Extinguishing System – Type: “ Ultrafog Nozzle type: 202-240-080-O”

FIXED LOCAL APPLICATION FIRE-FIGHTING SYSTEM

IMO MSC/ Circular 913, as amended by MSC.1/ Circ.1387

Expires: 6 May 2018

MED 1450078/ M1

Fixed Local Application Fire Extinguishing System – Type: “ Ultrafog High Pressure Waterfog System”

FIXED LOCAL APPLICATION FIRE-FIGHTING SYSTEM

IMO MSC.1/ Circ.1387 Expires: 9 June 2017

MED 1550085

Page 221: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.48 FIXED WATER BASED LOCAL APPLICATION FIRE FIGHTING SYSTEM S COM PONENTS FOR USE IN CATEGORY

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

221 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg, Denmark.

Fixed Local Application Fire Extinguishing System – Type: “ Skagerrak” Nozzles

FIXED LOCAL APPLICATION FIRE-FIGHTING SYSTEM

IMO MSC.1/ Circ. 1387 superseding MSC/ Circ. 913 (and superseding MSC.1/ Circ.1276)

Expires: 10 October 2021

MED 1750003

Page 222: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.51 FIXED FIRE DETECTION & FIRE ALARM SYSTEM S COM PONENTS FOR CONTROL STATIONS, SERVICE SPACES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

222 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Olympia Electronics, N. Lakasas - P. Arvanitidis S.A., 72klm Old National Road, Thessaloniki-Katerini, Kolindros, Greece.

Addressable fire detection and alarm system:

Addressable fire detection and alarm system, Conventional fire detection and alarm system

EN 54-2 (1997) including AC (1999) and A1 (2006) EN 54-4 (1997) including AC (1999), A1 (2002) and A2 (2006) EN 54-5 (2000) including A1 (2002) EN 54-7 (2000) including A1 (2002) and A2 (2006)

Expires: 3 November 2020 The following standards are not applicable to this equipment: - EN 60332-1-2 (2004) and - IEC 60092-376 (2003).

MED 1500021

Read as one Taboe Read as one Table

Model Description BSR-2114/ MAR Fire detection panel BSR- 2104/ MAR Fire detection panel BSR-6055/ A/ M AR Optical smoke detector BSR-6060/ A/ M AR Rate of rise heat detector

Operation Class/ Type IP Rating Voltage 220-240V AC 50-60Hz - IP30 220-240V AC 50-60Hz - IP30 21-28 V DC - IP44 18-30 V DC A2R IP22

BSR-5036/ A/ M AR Manual call point BSR-6057/ A/ M AR Optical smoke and thermal detector BSR-8017/ MAR Input-output unit BSR- 7071/ A/ M/ AR Base isolator BSR-2000/ MAR Repeater panel for BSR-2104/ MAR, BSR-2114/ MAR panels

21-28 V DC A IP44 21-28 V DC A2S IP44 21-28 V DC - IP20 14-30 V DC - IP20 220-240V AC 50-60Hz/ - IP30 16-30 V DC

Page 223: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.51 FIXED FIRE DETECTION & FIRE ALARM SYSTEM S COM PONENTS FOR CONTROL STATIONS, SERVICE SPACES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

223 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Conventional fire detection and alarm system:

Model Description BS-655/ MAR Optical smoke detector BS-536/ MAR Manual call point BS-657/ MAR Optical smoke and Thermal detector

Operation Class/ Type IP Rating Voltage 18-30 V DC - IP44 10-30 V DC A IP44 18-30 V DC A2R IP44

Software version: BSR-2114/ MAR & BSR-2104/ MAR fire detection panels detection panels BSR-2000/ MAR repeater panel

BSR-2100 V4.12 BSR-2000 V0.60

Page 224: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.51 FIXED FIRE DETECTION & FIRE ALARM SYSTEM S COM PONENTS FOR CONTROL STATIONS, SERVICE SPACES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

224 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Olympia Electronics ...continued

Type: BSR-8020/ WP/ MAR

Input/ Output Device EN 54-18:2005 +AC: 2007, IEC 60092-504 Ed. 4.0:2016 (incl. IEC 60092-504:2001 +Cor1:2011), IEC 60533:2015 (incl. IEC 60533:1999)

Expires: 9 March 2022

MED 1700005

Type: BS-1638/ MAR BS-1642/ MAR BS-1646/ MAR

Fire Detection & Alarm Control Panel EN 54-2:1997 +AC:1999 +A1:2006, EN 54-4:1997 +AC:1999 +A1:2002 +A2:2006, IEC 60092-504 3rd Ed.: 2001 +Cor1: 2011, IEC 60533:1999 Edition 2.0

Expires: 9 March 2022

MED 1700006

Type: BSR-7070/ A/ MAR

Line Isolator EN 54-17:2005/ AC:2007, IEC 60092-504 3rd Ed.: 2001 +Cor1: 2011, IEC 60533:1999 Edition 2.0

Expires: 9 March 2022

MED 1700007

Type: BS-660/ MAR

Heat Detector EN 54-5:2000 +A1:2002, IEC 60092-504 3rd Ed.: 2001 +Cor1: 2011, IEC 60533:1999 Edition 2.0

Expires: 9 March 2022

MED 1700009

Thorn Security Ltd, Security House, Hanworth Road, Sunbury-on-Thames, M iddlesex, TW6 5DB, United Kingdom (UK).

Addressable Detectors 811H (1) 811HExN (1) 811PH (1) (2) 811PHExN (1) (2) 811CH (1)(*)

A.1/ 3.51 FIXED FIRE DETECTION AND FIXED FIRE DETECTION AND FIRE ALARM SYSTEMS COMPONENTS FOR CONTROL STATIONS, SERVICE SPACES, ACCOMMODATION SPACES, MACHINERY SPACE AND UNATTENDED MACHINERY SPACES

(1) EN 54-5:2000 + A1:2002 (2) EN 54-7:2000 + A1:2002+A2:2006 (3) EN 54-10:2002 + A1:2005 IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011) IEC 60533 (1999) EN54-17(2007) Including AC(2007)

Expires: 1 July 2020 (*) Approved for use as heat detectors only

MED 1500010

Page 225: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.51 FIXED FIRE DETECTION & FIRE ALARM SYSTEM S COM PONENTS FOR CONTROL STATIONS, SERVICE SPACES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

225 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

811CHExN (1)(*) 811F(3) 811FEx(3) 811PC(1) (2)(*)

(*) Approved for use as heat detectors only Detector bases 801RB MUB MUBEx

5BEx 5BI (With Isolator) 5B

Page 226: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.51 FIXED FIRE DETECTION & FIRE ALARM SYSTEM S COM PONENTS FOR CONTROL STATIONS, SERVICE SPACES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

226 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Thorn Security Ltd ...continued

S200+ Flame Detectors S231f+ S231i+ S241i+ S241f+ S261f+ S271i+ S271f+

A.1/ 3.51 FIXED FIRE DETECTION AND FIXED FIRE DETECTION AND FIRE ALARM SYSTEMS COMPONENTS FOR CONTROL STATIONS, SERVICE SPACES, ACCOMMODATION SPACES, CABIN SPACES, MACHINERY SPACES AND UNATTENDED MACHINERY SPACES

EN 54-10 (2002) including A1 (2005) IEC 60092-504 Corrigendum 1 (2001) , IEC 60533 (1999)

Expires: 29 September 2020

MED 1500012

Software versions: S231f+ Version 1.5 S231i+ Version 1.5 S241i+ Version 1.5 S241f+ Version 1.5 S261f+ Version 1.5 S271i+ Version 1.6 S271f+ Version 1.6

Manual Call Points CP820M CP830M CP830Exn

A.1/ 3.51 FIXED FIRE DETECTION AND FIXED FIRE DETECTION AND FIRE ALARM SYSTEMS COMPONENTS FOR CONTROL STATIONS, SERVICE SPACES, ACCOMMODATION SPACES, CABIN SPACES, MACHINERY SPACES AND UNATTENDED MACHINERY SPACES

EN 54-11:2001 + A1:2005, IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999)

Expires: 29 September 2020

MED 1500013

Page 227: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.51 FIXED FIRE DETECTION & FIRE ALARM SYSTEM S COM PONENTS FOR CONTROL STATIONS, SERVICE SPACES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

227 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Addressable Panels T2000 T2000CV T2000R T2000RCV Software Version 22.0

A.1/ 3.51 FIXED FIRE DETECTION AND AND FIRE ALARM SYSTEMS COMPONENTS FOR CONTROL STATIONS, SERVICE SPACES, ACCOMMODATION SPACES, CABIN SPACES, MACHINERY SPACES AND UNATTENDED MACHINERY SPACES

EN 54-2:1997 + AC:1999 + A1:2006 EN 54-4:1997 + AC:1999 + A1:2002 + A2:2006 IEC 60092-504 (2001) + IEC 60092-504 Corrigendum 1 (2011) IEC 60533 (1999)

Expires: 29 September 2020

MED 1500014

Page 228: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.51 FIXED FIRE DETECTION & FIRE ALARM SYSTEM S COM PONENTS FOR CONTROL STATIONS, SERVICE SPACES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

228 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Thorn Security Ltd ...continued

Conventional Detectors MR601Tex(2) MD601Ex(1) MD611Ex(1) MDU601Ex(1)(*) 601P-M (2) 601CH-M (2)(*) 601H-R-M (1) 601H-F-M (1)

A.1/ 3.51 FIXED FIRE DETECTION AND FIXED FIRE DETECTION AND FIRE ALARM SYSTEMS COMPONENTS FOR CONTROL STATIONS, SERVICE SPACES, ACCOMMODATION SPACES, CABIN SPACRS, MACHINERY SPACES AND UNATTENDED MACHINERY SPACES

(1) EN 54-5:2000 + A1:2002 (2) EN 54-7:2000+A1:2002+A2:2006 (3) EN 54-10:2002+ A1:2005 IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011) IEC 60533 (1999)

Expires: 29 September 2020

MED 1500016

601PH-M (1) 631H-F(1) 611H-F(1) 601F-M (3 601FEx-M (3)

(*) Approved for use as heat detectors only

Detector bases 5BD MUB 5Bex 5B MUBEx

Thorn Security Ltd T/A Tyco Safety Products, Security House, Hanworth Road, Sunbury-on-Thames, TW16 5DB, United Kingdom (UK).

FV311S, FV311SC, FV311SC-N FV312S, FV312SC, FV312SC-N

Infra-Red Flame Detectors

EN 54-10:2002 + A1:2005 IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011) IEC 60533 (1999)

Expires: 6 May 2018

MED 1300008/ M1

Page 229: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.52 NON-PORTABLE AND TRANSPORTABLE FIRE EXTINGUISHERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

229 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Eversafe Extinguisher Sdn Bhd, Lot 878, Jalan Subang 9, Taman Perindustrian Subang, 47500 Subang Jaya, Selangor Darul Ehsan, M alaysia.

EVERSAFE, FireSafe, Red Panther and BRUDE Safety, Mobile Fire Extinguisher - Type: “ 25kg Dry Powder Stored Pressure - Model MPM-25, 50kg Dry Powder Stored Pressure – Model MPM-50”

NON-PORTABLE AND TRANSPORTABLE FIRE EXTINGUISHERS

EN 1866 (2005) & EN 1866-1 (2007) Expires: 5 May 2015

MED 1050103

EVERSAFE, FireSafe, Red Panther and BRUDE Safety, Mobile Fire Extinguisher - Type: “ 25kg Dry Powder, Gas Cartridge Operated - Model MPG-25, 50kg Dry Powder, Gas Cartridge Operated - Model MPG-50”

NON-PORTABLE AND TRANSPORTABLE FIRE EXTINGUISHERS

EN 1866 (2005) & EN 1866-1 (2007) Expires: 5 May 2015

MED 1050104

EVERSAFE, FireSafe, Red Panther and BRUDE Safety, Mobile Fire Extinguisher - Type: “ 45L Foam Stored Pressure - Model MFM-45, 135L Foam Stored Pressure - Model MFM-135”

NON-PORTABLE AND TRANSPORTABLE FIRE EXTINGUISHERS

EN 1866 (2005) & EN 1866-1 (2007) Expires: 5 May 2015

MED 1050105

EVERSAFE, FireSafe, Red Panther and BRUDE Safety, Mobile Fire Extinguisher - Type: “ 45L Foam, Gas Cartridge Operated - Model MFG-45, 135L Foam, Gas Cartridge Operated - Model MFG-135 150L Foam, Gas Cartridge Operated – Model MFG-150”

NON-PORTABLE AND TRANSPORTABLE FIRE EXTINGUISHERS

EN 1866 (2005) & EN 1866-1 (2007) Expires: 5 May 2015

MED 1050106

Page 230: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.52 NON-PORTABLE AND TRANSPORTABLE FIRE EXTINGUISHERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

230 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

EVERSAFE, FireSafe, Red Panther and BRUDE Safety, Mobile Fire Extinguisher CO2 - Types: “ 10kg CO2 Stored Pressure - Model MCO-10, Twin 10kg CO2 Stored Pressure – Model MCO-10T 20kg CO2 Stored Pressure – Model MCO-20”

NON-PORTABLE AND TRANSPORTABLE FIRE EXTINGUISHERS

EN 1866 (2005) & EN 1866-1 (2007) Expires: 5 May 2015

MED 1050107

Page 231: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.53 ALARM DEVICES - SOUNDERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

231 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Olympia Electronics, N. Lakasas - P. Arvanitidis S.A., 72klm Old National Road, Thessaloniki-Katerini, Kolindros, Greece.

Type: BS-531/ 1/ MAR ΒS-531/ 1/ WP/ MAR

Fire Alarm Sounder & Beacon EN 54-3:2001 +A1:2002 +A2:2006, EN 54-23:2010, EN 50130-4:2011, IEC 60092-504 3rd Ed.: 2001 +Cor1: 2011, IEC 60533:1999 Edition 2.0

Expires: 9 March 2022

MED 1700008

Thorn Security Ltd, Security House, Hanworth Road, Sunbury-on-Thames, M iddlesex, TW6 5DB, United Kingdom (UK).

Sounder Base 802SB

A.1/ 3.53 ALARM DEVICES - SOUNDERS

EN 54-3 (2001) including A1(2002) and A2(2006) IEC 60092-504 (2001) including IEC 60092-504 Corrigendum 1 (2011), IEC 60533 (1999)

Expires: 29 September 2020

MED 1500015

Page 232: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.54 FIXED OXYGEN ANALYSIS AND GAS DETECTION EQUIPM ENT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

232 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

GAS M EASUREM ENT INSTRUM ENTS LTD, Inchinnan Business Park, Renfrew, Scotland, PA4 9RG, United Kingdom (UK).

Gas detection system Type: ACTIVE - 8

IEC 60092-504 (2001) Incl IEC 60092-504 Corr1 (2011), IEC 60533 (1999) EN 50104 (2010) EN 60079-0 (2012), EN 60079-29-1(2007)

Expires: 9 June 2020 The following MED specified standards are not applicable to this product:- MSC.1/ Circ.1370

MED 1500008

M artek M arine Ltd., Unit 6A Adwick Park, Rotherham, South Yorkshire, S63 5AB, United Kingdom (UK).

Infrared Gas Sensor Type MM1200 IR

Refer to manufacturer’s brochure/ datasheet

EN 60945 (2002) IEC 60092-504 (2001) IEC 60533 (1999) EN 61779-1 (2000) EN 61779-4 (2000)

Expires: 28 January 2015

MED 1000001

Flameproof Flammable and Toxic Gas Detector Type MM1000 F1 (Flammable Gas Detection Only)

Refer to manufacturer’s brochure/ datasheet

EN 60945 (2002) IEC 60092-504 (2001) IEC 60533 (1999) EN 61779-1 (2000) EN 61779-4 (2000)

Expires: 28 January 2015

MED 1000002

Flameproof Flammable and Toxic Gas Detector Type MM2000 (Flammable Gas Detection Only)

Refer to manufacturer’s brochure/ datasheet

EN 60945 (2002) IEC 60092-504 (2001) IEC 60533 (1999) EN 61779-1 (2000) EN 61779-4 (2000)

Expires: 28 January 2015

MED 1000003

Page 233: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.55 DUAL-PURPOSE TYPE NOZZLES (SPRAY/JET TYPE)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

233 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Akron Brass Company, 343 Venture Blvd, P.O. Box 86, Wooster, OH 44691, United States of America (USA).

Hose Nozzle – Type: ‘TURBOJET’ Type 3 Dual Purpose Spray/ Jet nozzles Model Nos. 1702, 1720, 1733 and 1772

HOSE NOZZLE EN 15182-1:2007, EN 15182-3:2007 Expires: 17 March 2020

MED 1550060/ M2

Delta Fire Limited, Wendover Road, Rackheath Industrial Estate, Norwich, NR13 6LH, United Kingdom (UK).

Hand-held branchpipes for fire service use — Combination branchpipes PN 16: Type 2 and Type 3 Models- ‘Delta Attack 100’ and ‘Delta Attack 500’

HOSE NOZZLE EN 15182-1(2007) including A1(2009) EN 15182-2 (2007) including A1(2009)

Expires: 23 September 2021

MED 1650232

Page 234: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.6 FIREFIGHTER'S OUTFIT HELM ET

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

234 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Halo Imaging, Gadwall Road,, Rainton Bridge South Business Park,, Houghton-Le-Spring,, Tyne and Wear, DH4 5NL, United Kingdom (UK).

Fire-fighter’s Outfit Helmet with Integrated Facemask – Type: “ SOLOunifit” and “ SOLOtic”

PROTECTIVE CLOTHING European Standards EN 443 (2008), EN 137 (2006), EN 136 (1998) including AC (2003)

Expires: 15 August 2021

MED 1650279/ M3

Page 235: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.60 NOZZLES FOR FIXED PRESSURE WATER-SPRAYING FIRE-EXTINGUISHING SYSTEM S FOR CABIN BALCONIES

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

235 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Novenco Fire Fighting A/S, Lille Tornbjergvej 30, DK-5220 Odense, Denmark.

Fixed Fire Extinguishing System – Type: “ Cabin Balconies – Water Mist System”

FIXED PRESSURE WATER-SPRAYING SYSTEM FOR CABIN BALCONIES

IMO MSC.1/ Circ.1268 Expires: 21 June 2020

MED 1650021

Ultra Fog AB, Backa Strandgata 18, Hisings Backa, 422 46, Sweden.

Fixed Fire Extinguishing System – Type: “ Cabin Balconies – Water Mist System”

FIXED PRESSURE WATER-SPRAYING SYSTEM FOR CABIN BALCONIES

IMO MSC/ Circ.1268 Expires: 19 February 2018

MED 1450077/ M1

Page 236: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.61 INSIDE/OUTSIDE AIR HIGH EXPANSION FOAM SYSTEM S FOR THE PROTECTION OF M ACHINERY SPACES, CAR

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

236 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

FireStop AS, Gronland 101, 3045 Drammen, Norway.

Fire Extinguishing Low Expansion Foam Concentrate – Type: “ FireStopper XL PLUS 6%” Firefighting Catalyst Aqueous Concentrate.

FOAM CONCENTRATE IMO MSC.1/ Circ.1312 and Corr.1 Expires: 5 February 2019

MED 1450026

Firestopper International Limited, Burns House, 19 Town Range, Gibraltar.

Fire Extinguishing Low Expansion Foam Concentrate – Type: “ FireStopper XL PLUS 6%” Firefighting Catalyst Aqueous Concentrate.

FOAM CONCENTRATE IMO MSC.1/ Circ.1312 and Corr.1 Expires: 5 February 2019

MED 1450025/ M1

Kashiwa Co Ltd, 4-5-4, Takanawa, M inato-ku, Tokyo, 108-0074, Japan.

Fixed fire extinguishing system– Type: “ Inside Air Foam System using foam generator - Type: 60M D and 30M D”

INSIDE AIR HIGH EXPANSION FOAM SYSTEMS FOR THE PROTECTION OF MACHINERY SPACES AND CARGO PUMP ROOMS

IMO MSC.1/ Circ. 1384, which supersedes IMO MSC/ Circular 1271

Expires: 28 January 2021

MED 1650053

Page 237: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.64 'C' CLASS DIVISIONS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

237 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Foshan Hongzan Building M aterials Co Ltd, No 2, East Eco-industrial Park,, Lishui Town,, Nanhai District,, Foshan,, Guangdong,, 528244, China, People's Republic of.

Aluminium Honeycomb Panel with Low Flame Spread Adhesive-Type: “ AHP-A” , for use in C Class divisions

C Class Division IMO Res. MSC.307 (88)-(2010 FTP Code) Annex 1, Part 5 and Annex 2

Expires: 20 May 2019

MED 1450118

Page 238: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.7 SELF-CONTAINED COM PRESSED AIR-OPERATED BREATHING APPARATUS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

238 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Draeger Safety (UK) Limited, Ullswater Close, Blyth, Northumberland, NE24 4RG, United Kingdom (UK).

Compressed Air Open Circuit Breathing Apparatus – Type: “ Dräger PSS 7000 Series”

COM PRESSED AIR OPEN CIRCUIT BREATHING APPARATUS

EN 137 (2006), EN 136:1998 including AC (1999) and AC (2003) ISO 23269-3 (2011), when fitted with a Safety Line/ Pouch Kit

Expires: 12 February 2019

MED 1450029

Compressed Air Open Circuit Breathing Apparatus – Type: “ Dräeger PAS Lite Series, PSS 3000 Series and PSS 4000 Series”

COM PRESSED AIR OPEN CIRCUIT BREATHING APPARATUS

EN 136 (1998) including AC (1999) and AC (2003), EN 137 (2006). ISO 23269-3 (2011), when fitted with a Safety Line/ Pouch Kit.

Expires: 12 February 2019

MED 1450030/ M2

Compressed Air Open Circuit Breathing Apparatus – Type: “ Dräeger PSS 5000 Series” ”

COM PRESSED AIR OPEN CIRCUIT BREATHING APPARATUS

EN 136 (1998) including AC (1999) and AC (2003), EN 137 (2006). ISO 23269-3 (2011), when fitted with a Safety Line/ Pouch Kit.

Expires: 12 February 2019

MED 1450031

Page 239: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.9 SPRINKLERS SYSTEM S COM PONENTS FOR ACCOM M ODATION SPACES, SERVICE SPACES & CONTROL STATIONS E

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

239 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Firecon Group Oy, Otto Korhosen katu 1, 20660 Littoinen, Finland.

Fixed Fire Extinguishing System – Type: “ SOFTEX Fire Extinguishing System for Accommodation and Service Spaces – Equivalent to SOLAS II-2/ Regulation 10.6 (2009 edition)” , including additive

AUTOM ATIC SPRINKLER, FIRE DETECTION AND FIRE-ALARM SYSTEM

IMO Resolution A.800(19) as amended by IMO Resolution MSC.284 (86) for expiry date

Expires: 1 July 2015

MED 1150181/ M2

Knaack & Jahn Schiffbau GmbH, Uffelnsweg 10, 20539 Hamburg, Germany.

Sprinkler systems components Type: “ OHM Nozzles” for accommodation spaces, service spaces and control stations equivalent to that referred to in SOLAS II-2/ 10.6.1 & IMO FSS Code Chapter 8 (limited to sprinkler nozzles and their performance).

Automatic Sprinkler, Fire Detection And Fire-Alarm System

Resolution A.800(19), as amended by Resolutions MSC.265(84) and MSC. 284(86)

Expires: 10 October 2016

MED 1150273

Novenco A/S, Industrivej 22, DK 4700 Naestved, Denmark.

Fixed Fire Extinguishing System – Type: “ XFlow water mist system” for Accommodation Spaces, Service Spaces and Control Stations Equivalent to SOLAS II-2/ 10.6.1 and IMO FSS Code, Chapter 8.

AUTOM ATIC SPRINKLER, FIRE DETECTION AND FIRE-ALARM SYSTEM

IMO Resolution A.800(19), as amended by Resolutions MSC 265(84) and MSC 284(86)

Expires: 25 July 2018

MED 1350097

Novenco Fire Fighting, Industrivej 17, 4700 Naestved, Denmark.

Fixed Fire Extinguishing System – Type: “ Xflow Accommodation” Watermist System for Accommodation and Service Spaces, Equivalent to SOLAS II-2/ 10.6.1”

Automatic Sprinkler, Fire Detection And Fire-Alarm System

IMO Resolution A.800 (19)

Expires: 1 July 2015

MED 1250110

Tyco Fire Products M anufacturing Limited, Stockport Trading Estate, Yew Street, Stockport, SK4 2JW, United Kingdom (UK).

Fixed Fire Extinguishing System – Type: “ Aquamist Accommodation, Public Space and Service Area Water Mist System”

AUTOMATIC SPRINKLER, FIRE DETECTION AND FIRE-ALARM SYSTEM

IMO Resolution A.800 (19) as amended by IMO Resolution MSC.284 (86) for expiry date

Expires: 1 July 2015

MED 1250220

Page 240: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Fire protection Product: M ED/3.9 SPRINKLERS SYSTEM S COM PONENTS FOR ACCOM M ODATION SPACES, SERVICE SPACES & CONTROL STATIONS E

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

240 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Ultra Fog AB, Backa Strandgata 18, Hisings Backa, 422 46, Sweden.

Fixed Fire Extinguishing System – Type: “ Nozzle 603” Ultra Fog Fire Extinguishing System, for Accommodation Spaces, Service Spaces and Control Stations Equivalent to SOLAS II-2/ 10.6.1 and IMO FSS Code, Chapter 8

AUTOM ATIC SPRINKLER, FIRE DETECTION AND FIRE-ALARM SYSTEM

IMO Resolution A.800(19), as amended by Resolutions MSC.265(84) and Resolution MSC.284(86)

Expires: 14 February 2018

MED 1450095/ M2

VID Fire-Kill ApS, Svalbardvej 13, DK-5700 Svendborg, Denmark.

Fixed Fire Extinguishing System – Type: “ OH Nozzles” for Accommodation Spaces, Service Spaces and Control Stations Equivalent to SOLAS II-2/ 10.6.1 and IMO FSS Code, Chapter 8 (limited to sprinkler nozzles and their performance).

AUTOM ATIC SPRINKLER, FIRE DETECTION AND FIRE-ALARM SYSTEM

IMO Resolution A.800(19), as amended by Resolutions MSC.265(84) and MSC. 284(86)

Expires: 10 October 2021

MED 1750004

Page 241: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.1 LIFEBUOYS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

241 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

E.G. VALLIANATOS S.P.A. (EVAL), Location Tzaverdella, Ano Liosa, PC13341, P.O. Box 460 21, Athens, Greece.

Lifebuoy Throw–over Lifebuoy, not for use with light and or smoke signals, ≥ 2.5 kg; Type” 557 “

IMO Res. MSC.81(70), Part 1, as amended LSA code, Regulation II/ 2.1

Expires: 28 February 2022

MED 1750025

Quick release lifebuoy suitable for use with light and smoke signal, ≥ 4 kg; Type “ 558”

Lifebuoy LSA code, Regulation II/ 2.1 IMO Res. MSC.81(70), Part 1, as amended

Expires: 28 February 2022

MED 1750026

Throw–over Lifebuoy, not for use with light and or smoke signals, ≥ 2.5 kg; Type “ 559”

Lifebuoy LSA code, Regulation II/ 2.1 IMO Res. MSC.81(70), Part 1, as amended

Expires: 28 February 2022

MED 1750027

Survitec Services & Distribution Ltd. trading as Crewsaver, Crewsaver, M umby Road, Gosport, Hampshire, PO12 1AQ, United Kingdom (UK).

Throw-over lifebuoy - Type: “ 760mm, 2.5kg Perrybuoy”

Lifebuoys IMO Resolution MSC.81(70), Part 1 as amended by Resolution MSC.226(82)

Expires: 15 February 2016

MED 1150090/ M1

Quick release lifebuoy for use w ith light and/ or smoke signal - Type: “ 760mm, 4.3kg Perrybuoy”

Lifebuoys IMO Resolution MSC.81(70), Part 1 as amended by Resolution MSC.226(82)

Expires: 15 February 2016

MED 1150091/ M1

Page 242: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.10 BUOYANT SM OKE SIGNALS (PYROTECHNICS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

242 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Drew M arine Signal & Safety Spain SL, Camino M endi S/N, Esquiroz de Galar, Navarra, 31191, Spain.

Buoyant smoke signal - Type:- "KEL"

Pyrotechnics IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82) and MSC.323 (89)

Expires: 22 January 2021

MED 1650089

Page 243: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.12 INFLATABLE LIFERAFTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

243 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai Star Rubber Products Co. Ltd, No. 4968 Sichen Highway, Songjiang District, Shanghai, China, People's Republic of.

16 persons capacity davit launched canopied inflatable liferafts – Type “RAFT-D16”

Liferafts IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82) and MSC.295(87) ISO 15738 : 2002

Expires: 16 June 2015

MED 1050134/ M1

20 person capacity davit launched inflatable liferafts – Type: “RAFT-D20”

Liferafts IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82) and MSC.295(87) ISO 15738 : 2002

Expires: 16 June 2015

MED 1050135/ M1

25 Persons capacity davit launched canopied inflatable liferafts – Type: “RAFTS-D25”

Liferafts IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82) and MSC.295(87) ISO 15738 : 2002

Expires: 16 June 2015

MED 1050136/ M1

6 persons capacity throw or roll-overboard canopied inflatable liferafts – Type: “RAFT-A-6 (I I )”

Liferafts IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82) and MSC.295(87) ISO 15738 : 2002

Expires: 14 June 2015

MED 1050137/ M1

10 persons capacity throw or roll-overboard canopied inflatable liferafts – Type: “RAFT-A-10 (I I )”

Liferafts IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82). ISO 15738 : 2002

Expires: 14 June 2015

MED 1050138

15 persons capacity throw or roll-overboard canopied inflatable liferafts – Type: “RAFT-A-15 (I I )”

Liferafts IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82) and MSC.295(87) ISO 15738 : 2002

Expires: 14 June 2015

MED 1050139/ M1

Page 244: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.12 INFLATABLE LIFERAFTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

244 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

16 persons capacity throw or roll-overboard canopied inflatable liferafts – Type: “RAFT-A-16 (I I )”

Liferafts IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82) and MSC.295(87) ISO 15738 : 2002

Expires: 14 June 2015

MED 1050140/ M1

20 persons capacity throw or roll-overboard canopied inflatable liferafts – Type: “RAFT-A-20 (I I )”

Liferafts IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82) and MSC.295(87) ISO 15738 : 2002

Expires: 14 June 2015

MED 1050141/ M1

25 persons capacity throw or roll-overboard canopied inflatable liferafts – Type: “RAFT-A-25 (I I )”

Liferafts IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82) and MSC.295(87) ISO 15738 : 2002

Expires: 14 June 2015

MED 1050142/ M1

Page 245: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.12 INFLATABLE LIFERAFTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

245 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Survitec Group, Kingsway, Dunmurry, Belfast, BT17 9AF, Northern Ireland.

12 person, 16 person, 20 person, 25 person davit launched canopied Surviva MkIV inflatable liferaft hull, packaged for extended service intervals - Type: ‘RFD Endura R’ (also known as ‘Survitec ESR’, ‘DSB LR07E’, ‘Survitec Zodiac ESP’, ‘Crewsaver ESR’ & ‘Elliot ESR’)

LIFERAFTS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.295 (87), Resolution MSC.274 (85), Resolution MSC.226 (82) and MSC.323 (89) MSC.1/ Circ.1328

Expires: 3 October 2017

MED 1250190/ M3

6 person, 8 person, 10 person, 12 person , 16 person, 20 person, 25 person throw-over / roll-over canopied Surviva MkIV inflatable liferaft hull, packaged for extended service intervals - Type: ‘RFD Endura R’ (also known as ‘Survitec ESR’, ‘DSB LR07E’, ‘Survitec Zodiac ESP’, ‘Crewsaver ESR’ & ‘Elliot ESR’).

LIFERAFTS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.295 (87), Resolution MSC.274 (85), Resolution MSC.226 (82) and MSC.323 (89) MSC.1/ Circ.1328

Expires: 3 October 2017

MED 1250191/ M3

6 persons, 8 persons, 10 persons, 12 persons, 16 persons, 20 persons, 25 persons capacity throw or roll-overboard canopied inflatable liferafts - Type: “ RFD Surviva MKIV” (also known as Beaufort Seafarer, DSB LR07, EV Solas Silver, EV TO M10, Crewsaver, Elliot, Survitec Zodiac SZ2 and DBC)

LIFERAFTS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.295 (87), Resolution MSC.274 (85), Resolution MSC.226 (82) and Resolution MSC.323 (89).

Expires: 25 November 2017

MED 1250241/ M8

Page 246: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.12 INFLATABLE LIFERAFTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

246 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

12 persons, 16 persons, 20 persons, 25 persons davit launched canopied inflatable liferafts - Type: “ RFD Surviva DL MKIV” (also known as Beaufort Seafarer DL, DSB LR07L, EV DL M10, Crewsaver, Elliot, Survitec Zodiac SZ2 and DBC)

LIFERAFTS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.295 (87), Resolution MSC.274 (85), Resolution MSC.226 (82) and Resolution MSC.323 (89).

Expires: 25 November 2017

MED 1250242/ M4

25 person davit launched inflatable liferaft - Type: “ RFD TOYO M kIV 25 DL”

LIFERAFTS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.295 (87), Resolution MSC.274 (85), Resolution MSC.226 (82) and Resolution MSC.323 (89).

Expires: 11 February 2019

MED 1450027

6 persons, 10persons,16 persons,20 persons, 25 persons throw-over/ roll-over inflatable liferaft - Type: “ RFD TOYO M k IV ”

LIFERAFTS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.295 (87), Resolution MSC.274 (85), Resolution MSC.226 (82) and Resolution MSC.323 (89).

Expires: 11 February 2019

MED 1450028

Page 247: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.12 INFLATABLE LIFERAFTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

247 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Survitec Group ...continued 158 person canopied reversible inflatable liferaft – Type: “ M ARIN ARK M K I I Liferaft”

LIFERAFTS IMO Resolution MSC.81 (70) Part 1 as amended by MSC.226 (82), MSC.295 (87) and MSC.323 (89) ISO 15738:2002

Expires: 23 March 2019

MED 1450064

12 persons , 16 persons , 20 persons , 25 persons davit launched inflatable liferaft - Type: “ RFD Surviva DL M kI I I ” also known as “ Beaufort Seafarer DL M kI I I ” and “ DSB LR05L”

LIFERAFTS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.295 (87) and MSC.323 (89).

Expires: 2 July 2019

MED 1450155/ M1

6 persons, 8 persons, 10 persons, 12 persons, 16 persons, 20 persons, 25 persons throw over or roll over inflatable liferaft – Type: “ RFD Surviva M k I I I ” also known as “ Beaufort Seafarer” and “ DSB LR05”

LIFERAFTS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.295 (87) and MSC.323 (89).

Expires: 2 July 2019

MED 1450156/ M1

6 persons, 8 persons, 10 persons, 12 persons, 16 persons, 20 persons, 25 persons capacity throw or roll-overboard canopied inflatable liferafts - Type: “UNITOR”

LIFERAFTS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.295 (87), Resolution MSC.274 (85), Resolution MSC.226 (82) and Resolution MSC.323 (89).

Expires: 10 September 2019

MED 1450187

12 persons, 16 persons, 20 persons, 25 persons davit launched canopied inflatable liferafts - Type: “UNITOR DL”.

LIFERAFTS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.295 (87), Resolution MSC.274 (85), Resolution MSC.226 (82) and Resolution MSC.323 (89).

Expires: 10 September 2019

MED 1450188

Page 248: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.12 INFLATABLE LIFERAFTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

248 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

6 persons, 10 persons and 25 persons capacity throw or roll-overboard canopied inflatable liferafts - Type: “RFD Surviva M KIV” (also known as Beaufort Seafarer, DSB LR07, EV Solas Silver, EV TO M10, Crewsaver, Elliot, Survitec Zodiac and DBC)

LIFERAFTS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.295 (87), Resolution MSC.274 (85), Resolution MSC.226 (82) and Resolution MSC.323 (89)

Expires: 28 January 2021

MED 1650050

6 person, 10 person and 25 person throw-over / roll-over canopied Surviva MkIV inflatable liferaft hull, packaged for extended service intervals - Type: ‘RFD Endura R’ (also known as ‘Survitec ESR’, ‘DSB LR07E’, ‘Survitec Zodiac ESP’, ‘Crewsaver ESR’ & ‘Elliot ESR’).

LIFERAFTS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.295 (87), Resolution MSC.274 (85), Resolution MSC.226 (82) and MSC.323 (89) MSC.1/ Circ.1328

Expires: 28 January 2021

MED 1650051

Page 249: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.14 AUTOM ATICALLY SELF-RIGHTING LIFERAFTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

249 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Survitec Group, Kingsway, Dunmurry, Belfast, BT17 9AF, Northern Ireland.

35 person throw-over/ roll-overs canopied automatically self-righting liferafts package for extended service intervals. Type: RFD Endura R 35 SR TO (also known as ‘Survitec ESR’, ‘DSB LR97E’, ‘Survitec Zodiac ESP’, ‘Crewsaver ESR’ & ‘Elliot ESR’).

LIFERAFTS SOLAS 74, as amended, Regulations III/ 4, 20.8.3, 34 and X/ 3 IMO Resolution MSC.48 (66), LSA Code, Regulations I/ 1.2, IV/ 4.1 and 4.2 IMO Resolution MSC.97 (73), 2000 HSC Code, Regulation 8.1 IMO MSC/ Circular 811, MSC/ Circ 809 IMO Resolution MSC.81 (70), Part 1 as

Expires: 30 September 2017

MED 1250185/ M2

amended by MSC.295 (87) and MSC.323 (89) IMO MSC.1/ Circ.1328

Survitec Group Ltd., RFD Beaufort Limited, 1-5 Beaufort Road, Birkenhead, M erseyside, CH41 1HQ, United Kingdom (UK).

35 person’s davit-launched canopied inflatable automatically self-righting liferafts package for extended service intervals. Type: RFD Endura R 35 SR DL (also known as DSB LR 97 E 35LSR, SURVITEC ESR35DL, SURVITEC ZODIAC EPS 35DL, CREWSAVER ESR, ELLIOT ESR).

AUTOM ATICALLY SELF-RIGHTING LIFERAFTS

SOLAS 74, as amended, Regulations III/ 4, 20.8.3, 34 and X/ 3 IMO Resolution MSC.48 (66), LSA Code, Regulations I/ 1.2, IV/ 4.1 and 4.2 IMO Resolution MSC.97 (73), 2000 HSC Code, Regulation 8.1 IMO MSC/ Circular 811, MSC/ Circ 809 IMO Resolution MSC.81 (70), Part 1 as

Expires: 30 September 2017

MED 1250183/ M2

amended by MSC.295 (87) and MSC.323 (89) IMO MSC.1/ Circ.1328

Page 250: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.15 CANOPIED REVERSIBLE LIFERAFTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

250 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Survitec Group, Kingsway, Dunmurry, Belfast, BT17 9AF, Northern Ireland.

100 person roll-over canopied reversible inflatable liferaft - Type: “ RFD SURVIVA 100” (also known as “ BEAUFORT SEAFARER 100, SURVITEC ZODIAC 100 and DBC 100” )

LIFERAFTS IMO MSC/ Circ.809 Annex IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82) MSC.295 (87) and MSC.323 (89) ISO 15738 (2002)

Expires: 14 March 2019

MED 1450066/ M1

50 person roll-over canopied reversible inflatable liferaft - Type: “ RFD SURVIVA 50” (also known as “ BEAUFORT SEAFARER 50, SURVITEC ZODIAC 50 and DBC 50” )

LIFERAFTS IMO MSC/ Circ.809 Annex IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.295 (87) and MSC.323 (89) ISO 15738 (2002)

Expires: 14 March 2019

MED 1450067/ M1

Survitec Group Limited, Beaufort Road, Birkenhead, M erseyside, CH41 1HQ, United Kingdom (UK).

109 person roll over canopied reversible inflatable liferaft – Type: “ MARIN ARK Liferaft”

LIFERAFTS IMO MSC/ Circ.809 Annex IMO Resolution MSC.81 (70), Part 1 as amended by Resolution MSC.226 (82), Resolution MSC.295 (87) and Resolution MSC.323 (89). ISO 15738 (2002)

Expires: 3 June 2018

MED 1350065

Page 251: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.16 FLOAT-FREE ARRANGEM ENTS FOR LIFERAFTS (HYDROSTATIC RELEASE UNIT)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

251 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Salcom M arine Products Ltd, 120 St Asaph Street, P.O. Box 22 621, Christchurch 8142, New Zealand.

Disposable automatic or local manually operated hydrostatic release unit forming part of liferaft lashing. – Type: “ S-R Mk1 HRU”

Hydrostatic Release Units IMO Resolution MSC.81(70) Part 1, as amended by Res.MSC.200(80).

Expires: 4 July 2015

MED 1050202

And USCG

Module B number:

160.162/ EC0038

Page 252: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

252 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Boatbuilding Yard, Qingdao Beihai Shipbuilding Heavy Industry Co. Ltd, #369 Lijiang East Road, Economic and Technical Development Zone, Qingdao, 266520, China, People's Republic of.

22 person davit launched totally enclosed GRP lifeboat/ rescue boat - Type: “ BH-5S (Cargo version)”

Lifeboat/ Rescue Boats IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 19 April 2016

MED 1150285

22 person davit launched totally enclosed GRP lifeboat/ rescue boat fitted w ith a self contained air support system and a water spray fire protection system – Type: “ BH-5S (Tanker version)”

LIFEBOAT/RESCUE BOATS IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 19 April 2016

MED 1150286

LIFEBOATS A.1/1.17 LIFEBOATS (b) Free-fall Lifeboats

30 persons free-fall launched, totally enclosed, GRP Lifeboat w ithout self-contained air support system and water spray fire protection system - Type: “BH-F670” Cargo

Expires: 11 October 2020

MED 1550234

China Shanghai Jiangnan Boatbuilding Co., Ltd., #999, Hailong Road, Fengxian, Shanghai, 201424, China, People's Republic of.

34 persons Free Fall Launched totally enclosed GRP Lifeboat - Type: “ JN-75FC” (Cargo version)

Lifeboats IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 14 December 2015

MED 1250011

Page 253: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

253 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

CSSC Nanjing Luzhou M achine Co., Ltd, Zhenjiang M arine Auxiliary M achinery Works, #56 Yuehe Street, Jianbi Town, Zhenjiang City, Jiangsu Province, 212006, China, People's Republic of.

32 persons Free Fall Launched totally enclosed GRP Lifeboat Type: “YH6.7FP” (Cargo Version

LIFEBOATS IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274 (85) IMO MSC./ Circular 1006

Expires: 22 July 2018

MED 1350131

32 persons Free Fall Launched totally enclosed GRP Lifeboat Type: “YH6.7FN” (Tanker Version

LIFEBOATS IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274 (85) IMO MSC./ Circular 1006

Expires: 22 July 2018

MED 1350132

Page 254: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

254 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

CSSC Nanjing Luzhou M achine Co., Ltd ...continued

41 persons Free Fall Launched totally enclosed GRP Lifeboat Type: “YH8.5 FP” (Cargo Version)

LIFEBOATS IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82), MSC.274 (85), MSC.295 (87) & MSC.323 (89). IMO MSC./ Circular 1006

Expires: 21 April 2020

MED 1550086

41 persons Free Fall Launched totally enclosed GRP Lifeboat Type: “YH8.5 FN” (Tanker Version)

LIFEBOATS IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82), MSC.274 (85), MSC.295 (87) & MSC.323 (89). IMO MSC./ Circular 1006

Expires: 21 April 2020

MED 1550087

40 person davit launched totally enclosed GRP lifeboat/ rescue boat with self-contained air support and water spray fire protection system - Type: “YH6.5QFN (Tanker Version)”

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC Circular 1006

Expires: 25 January 2021

MED 1650043/ M1

40 person davit launched totally enclosed GRP lifeboat/ rescue boats - Type: “YH6.5QFP (Cargo Version)”

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC Circular 1006

Expires: 25 January 2021

MED 1650044/ M1

Fr Fassmer GmbH & Co. KG, Industriestr. 2, 27804 Berne, Germany.

150 person davit launched partially enclosed tw in screw GRP lifeboat - Type: “ Fassmer SEL-T 11.7-E2”

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC 226(82), MSC 274(85) and MSC 321(89). MSC Circular 1006.

Expires: 21 August 2021

MED 1650214

Page 255: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

255 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

150 person davit launched partially enclosed tw in screw GRP lifeboat - Type: “ Fassmer SEL-T 11.0-E2”

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC 226(82), MSC 274(85) and MSC 321(89) MSC Circular 1006

Expires: 25 August 2021

MED 1650216

150 person davit launched partially enclosed tw in screw GRP lifeboat - Type: “ Fassmer SEL-T 11.7-SSI ”

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC 226(82), MSC 274(85) and MSC 321(89). MSC Circular 1006.

Expires: 11 October 2021

MED 1650255

Harding Safety AS, Seimsvegen 116, 5472 Seimsfoss, Norway.

150 person davit launched totally enclosed GRP lifeboat– Type: “ CTL38” (Passenger vessel only)

Lifeboat IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) IMO MSC./ Circular 1006

Expires: 14 May 2017

MED 1250088

Page 256: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

256 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Harding Safety AS ...continued

70 person davit launched totally enclosed GRP lifeboat/ rescue boat w ith self-contained air support and water spray fire protection system - Type: “KISS 800 (Tanker Version)”

Lifeboats IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC Circular 1006 IMO MSC.1/ Circ 1393

Expires: 19 September 2017

MED 1250166/ M2

70 person davit launched totally enclosed GRP lifeboat/ rescue boat - Type: “KISS 800 (Cargo Version)”

Lifeboats IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC Circular 1006 IMO MSC.1/ Circ 1393

Expires: 19 September 2017

MED 1250167/ M2

70 person free fall totally enclosed GRP lifeboat w ith self-contained air support system and water spray fire protection system. – Type: “ FF1200” (Tanker version)

Lifeboats IMO Resolution MSC.81(70), Part 1 as amended by MSC.218(82), MSC.226(82),MSC.323(89) and MSC.274(85) IMO MSC/ Circ.1006

Expires: 25 June 2019

MED 1450145

150 person davit launched partially enclosed GRP lifeboat– Type: “CTL38” range (CTL38 SV included) (Passenger vessel only)

LIFEBOATS IMO Resolution MSC.81(70), Part 1 as amended by Resolution MSC 226(82) MSC, MSC.321(89), MSC.323(89). MSC Circular 1006.

Expires: 29 October 2019

MED 1450222/ M2

90/ 83 persons davit launched totally enclosed GRP lifeboat w ith a self contained air support system and a water spray fire protection system – Type: “KISS1000” (Tanker Version)

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC Circular 1006 IMO MSC.1/ Circ 1393

Expires: 8 July 2020

MED 1550065/ M1

Page 257: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

257 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Harding Safety AS, 5472 Seimsfoss, Norway.

90/ 83 persons davit launched totally enclosed GRP lifeboat - Type: “KISS 1000 (Cargo Version)”

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82) MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC Circular 1006 IMO MSC.1/ Circ 1393

Expires: 8 July 2020

MED 1550160/ M1

Page 258: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

258 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

HLB CO., Ltd., 272-12, Dangwol-ro, Onsan-Eup, Ulju-Gun, Ulsan, 689-892, Korea, Republic of.

Davit launched totally enclosed GRP lifeboat/ rescue boat w ith a self-contained air support system and a fire protection system – Type: “ HDL 75 CFR” (Tanker Version) No of Persons: 46, for tanker vessels with keel laying date before 1st July 2010. No of Persons: 41, for tanker vessels with keel laying date after 1st July 2010.

Lifeboat/ Rescue Boats IMO Resolution MSC.81(70), Part 1 as amended by resolution MSC 226(82) and MSC 274(85). MSC Circular 1006.

Expires: 16 August 2015

MED 1050218

Davit launched totally enclosed GRP lifeboat/ rescue – Type: “ HDL 75 CTR” (Cargo Version) No of Persons :46, for cargo vessels with keel laying date before 1st July 2010. No of Persons :41, for cargo vessels with keel laying date after 1st July 2010.

Lifeboats

IMO Resolution MSC.81(70), Part 1 as amended by resolution MSC 226(82) and MSC 274(85). MSC Circular 1006.

Expires: 5 September 2015

MED 1050241

61 persons davit launched totally enclosed GRP lifeboat/ rescue boat – Type: “ HDL 85 CNT” (Cargo Version)

Lifeboats IMO Resolution MSC.81(70), Part 1 as amended by Resolution MSC 226(82) and MSC 274(85). MSC. Circular 1006

Expires: 26 January 2016

MED 1150048

Davit launched totally enclosed GRP lifeboat/ rescue boat with a self contained air support system and with a fire protection system – Type: “ HDL 71 CFA (Tanker Version)” No of Persons: 36, for tanker vessels w ith keel laying date before 1st July 2010. No of Persons: 32, for tanker vessels w ith keel laying date after 1st July 2010.

A.1/ 1.17 - Lifeboats And A.1/ 1.18 – Rigid Rescue Boats

IMO Resolution MSC.81(70), Part 1 as amended by resolution MSC 226(82) and MSC 274(85). MSC Circular 1006.

Expires: 5 January 2016

MED 1150074

Page 259: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

259 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Davit launched totally enclosed GRP lifeboat/ rescue boat– Type: “ HDL 71 CTA (Cargo Version)” No of Persons: 36, for cargo vessels with keel laying date before 1st July 2010. No of Persons: 32, for cargo vessels with keel laying date after 1st July 2010.

A.1/ 1.17 – Lifeboats And A.1/ 1.18 – Rigid Rescue Boats

IMO Resolution MSC.81(70), Part 1 as amended by resolution MSC 226(82) and MSC 274(85). MSC Circular 1006.

Expires: 9 January 2016

MED 1150075

Page 260: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

260 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

HLB CO., Ltd. ...continued 61 persons davit launched totally enclosed GRP lifeboat/ rescue boat w ith a self-contained air support system and fire protection system – Type: “ HDL 85 CNF” (Tanker Version)

LIFEBOATS IMO Resolution MSC.81(70), Part 1 as amended by Resolution MSC 226(82) and MSC 274(85). MSC. Circular 1006.

Expires: 7 April 2016

MED 1150106

Davit launched / totally enclosed GRP Lifeboat / Rescue Boat Type: “HDL71CTR” (Cargo Version) No of Persons: 36, for cargo vessels with keel laying date before 1st July 2010. No of Persons: 32, for cargo vessels with keel laying date after 1st July 2010.

Lifeboat/ Rescue Boats IMO Resolution MSC.81(70), Part 1 as amended by resolution MSC 226(82) and MSC 274(85). MSC Circular 1006.

Expires: 5 December 2016

MED 1150299

Davit launched / totally enclosed GRP Lifeboat / Rescue Boat with self-contained air support system and water spray fire protection system. Type: “HDL71CFR” (Tanker Version) No of Persons: 36, for tanker vessels with keel laying date before 1st July 2010. No of Persons: 32, for tanker vessels with keel laying date after 1st July 2010.

Lifeboat/ Rescue Boats IMO Resolution MSC.81(70), Part 1 as amended by resolution MSC 226(82) and MSC 274(85). MSC Circular 1006.

Expires: 5 December 2016

MED 1150300

61 persons davit launched totally enclosed GRP lifeboat/ rescue boat w ith a self-contained air support system and fire protection system – Type: “ HDL 85 CNF w ith On Load Release Mechanism Talon II 6.0” (Tanker Version)

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by Resolution MSC 226 (82),MSC.323 (89) and MSC 274 (85) MSC. Circular 1006 IMO MSC.1/ Circ 1393

Expires: 4 November 2017

MED 1250225

Page 261: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

261 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

61 persons davit launched totally enclosed GRP lifeboat/ rescue boat – Type: “ HDL 85 CNT with On Load Release Mechanism Talon II 6.0” (Cargo Version)

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC Circular 1006 IMO MSC.1/ Circ 1393

Expires: 4 November 2017

MED 1250226

32 persons Davit launched totally enclosed GRP lifeboat/ rescue boat w ith a self contained air support system and with a fire protection system – Type: “ HDL 71 CFA with On Load Release Mechanism Talon II 4.0” (Tanker Version)

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.323 (89), MSC.274 (85) and MSC.321 (89) IMO MSC Circular 1006 IMO MSC.1/ Circ 1393

Expires: 4 November 2017

MED 1250227

Page 262: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

262 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

HLB CO., Ltd. ...continued 32 persons Davit launched totally enclosed GRP lifeboat/ rescue boat– Type: “ HDL 71 CTA with On Load Release Mechanism Talon II 4.0” (Cargo Version)

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82) ,MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC Circular 1006 IMO MSC.1/ Circ 1393

Expires: 4 November 2017

MED 1250228

41 persons davit launched totally enclosed GRP lifeboat/ rescue boat w ith a self-contained air support system and a fire protection system – Type: “ HDL 75 CFR WITH TALON I I 4.0” (Tanker Version)

LIFEBOAT/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC 226(82) and MSC 274(85), MSC.323 (89) and MSC.321 (89). MSC Circular 1006

Expires: 30 May 2018

MED 1350071

41 persons davit launched totally enclosed GRP lifeboat/ rescue boat– Type: “ HDL 75 CTR WITH TALON I I 4.0” (Cargo Version)

LIFEBOATS/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC 226(82) and MSC 274(85), MSC.323 (89) and MSC.321 (89). MSC Circular 1006.

Expires: 30 May 2018

MED 1350072

40 persons davit launched totally enclosed GRP lifeboat/ rescue boat with a self-contained air support system and with a fire protection system – Type: “ HDL 75 CF WITH TALON II 4.0” (Tanker Version)

LIFEBOAT/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC 226(82) and MSC 274(85), MSC.323 (89) and MSC.321 (89). MSC Circular 1006.

Expires: 30 May 2018

MED 1350074

40 persons davit launched totally enclosed GRP lifeboat/ rescue boat – Type: “ HDL 75 CT WITH TALON I I 4.0” (Cargo Version).

LIFEBOAT/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.226 (82) and MSC.274 (85), MSC.323 (89) and MSC.321 (89). MSC Circular 1006.

Expires: 30 May 2018

MED 1350075

Page 263: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

263 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Davit launched totally enclosed GRP Lifeboat Type: “HLB105F” (Tanker Ship Version)

TOTALLY ENCLOSED LIFEBOAT IMO Resolution MSC.81 (70), Part 1 as amended by Res. MSC.218 (82), MSC.226 (82), MSC. 274(85), MSC.323 (89) and MSC.321 (89). IMO MSC/ Circ. 1006

Expires: 23 June 2018

MED 1350089

Davit launched totally enclosed GRP lifeboat/ rescue boat – Type: “HDL 65 CT” (Cargo Version) with release mechanism system type TALON II 4.0.

LIFEBOATS/RESCUE BOATS IMO Resolution MSC.81(70), Part 1 as amended by resolution MSC 226(82) MSC 274(85),MSC.321(89),MSC.323(89). MSC Circular 1006.

Expires: 3 March 2019

MED 1450046/ M1

Page 264: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

264 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

HLB CO., Ltd. ...continued Davit launched totally enclosed GRP lifeboat/ rescue boat with a self-contained air support system and with a fire protection system - Type: “HDL 65 CF” (Tanker Version) with release mechanism system type TALON II 4.0

LIFEBOATS/RESCUE BOATS IMO Resolution MSC.81(70), Part 1 as amended by resolution MSC 226(82) MSC 274(85),MSC.321(89),MSC.323(89). MSC Circular 1006

Expires: 3 March 2019

MED 1450047/ M1

35 persons free-fall launched, totally enclosed, GRP Lifeboat, with self-contained air support system and water spray fire protection system - Type: “HDFN35F” (Tanker Version)

LIFEBOATS IMO Resolution MSC.81(70) Part 1, as amended. IMO MSC Circular 1006

Expires: 25 March 2020

MED 1550184

35 persons free-fall launched, totally enclosed, GRP Lifeboat - Type: “HDFN35T” (Cargo Version)

LIFEBOATS IMO Resolution MSC.81(70) Part 1, as amended. IMO MSC Circular 1006.

Expires: 25 March 2020

MED 1550185

25 persons freefall launched, totally enclosed, GRP Lifeboat, with self-contained air support system and water spray fire protection system - Type: “HDFN25F” (Tanker Version)

Lifeboats IMO Resolution MSC.81(70) Part 1, as amended IMO MSC Circular 1006

Expires: 6 March 2021

MED 1650119

25 persons freefall launched, totally enclosed, GRP Lifeboat - Type: “HDFN25T” (Cargo Version)

Lifeboats IMO Resolution MSC.81(70) Part 1, as amended IMO MSC Circular 1006

Expires: 6 March 2021

MED 1650120

Holland Lifeboats International B.V., Brielselaan 69, 3081 AA Rotterdam, Netherlands, The.

15 Person Totally Enclosed GRP Lifeboat/ Rescue boat w ith self contained air support system and water spray fire protection system - Type: “TELB 65/15 T/R” (Tanker version) .

Lifeboat/ Rescue Boats IMO Resolution MSC.81(70) , Part 1 as amended by Part 1 as amended by MSC 226 (82) and MSC 274 (85) IMO MSC/ Circular 1006

Expires: 23 January 2016

MED 1150039

Page 265: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

265 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lifeboat/ Rescue Boats 50 Person Totally Enclosed GRP Lifeboat/ Rescue boat w ith self contained air support system and water spray fire protection system - Type: “ TELB 75/ 50 T/ R” (Tanker version)

IMO Resolution MSC.81(70) , Part 1 as amended by MSC 226 (82) and MSC 274 (85) IMO MSC/ Circular 1006

Expires: 4 July 2016

MED 1150196

Jiangsu Jiaoyan M arine Equipment Co. Ltd., No. 14 North Street, Yuecheng Town, Jiangyin City, Jiangsu Province, 214404, China, People's Republic of.

LIFEBOATS 30 person Free Fall launched totally enclosed GRP lifeboat - Type: “JYM -FN 6.65” (Cargo Version)

IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274 (85) IMO MSC./ Circular 1006

Expires: 24 March 2018

MED 1350042

Page 266: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

266 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jiangsu Jiaoyan M arine Equipment Co. Ltd. ...continued

30 person Free Fall launched totally enclosed GRP lifeboat with self-contained air support system and water spray fire protection system - Type: “JYM -FF 6.65” (Tanker Version)

LIFEBOATS IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274 (85) IMO MSC./ Circular 1006

Expires: 24 March 2018

MED 1350043

Jiangyin Neptune M arine Appliance Co. Ltd, 25# North Road, Yuecheng Town, Jiangyin City, Jiangsu Province, China, People's Republic of.

25 person Freefall Totally Enclosed GRP Lifeboat w ith self-contained air support system and water spray fire protection system - Type: “ NPT59FF (Tanker version) “

Lifeboats IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 6 February 2016

MED 1050372

26 person freefall totally enclosed GRP lifeboat - Type: “ NPT59FC (Cargo ship version] “

Lifeboats

SOLAS 74, as amended, Regulation III/ 4, 34, 35, 36 and X/ 3 The LSA Code, Regulations I/ 1.2 and IV/ 4.4, 4.6 and 4.7. IMO Resolution MSC.81(70) Part 1, as amended to date

Expires: 6 February 2016

MED 0950260

36 person Freefall Totally Enclosed GRP Lifeboat w ith self-contained air support system and water spray fire protection system - Type: “ NPT76FF (Tanker version) “

Lifeboats IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 23 April 2017

MED 1250069

36 persons Freefall Totally Enclosed GRP Lifeboat Type: “ NPT76FC (Cargo version) “

Lifeboats IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 23 April 2017

MED 1250070

Page 267: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

267 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jiangyin Wolong F.R.P Boat Co. Ltd, Yuecheng Town, Jiangyin City, Jiangsu, 214404, China, People's Republic of.

33 persons freefall launched totally enclosed GRP lifeboat – Type: “ JY67CF” (Cargo version)

Lifeboats

IMO Resolution MSC.81(70) Part 1, as amended by resolution MSC 226(82) and MSC 274 (85). IMO MSC Circular 1006.

Expires: 15 December 2015

MED 1050354

33 persons freefall launched totally enclosed GRP lifeboat, with self-contained air support system and water spray fire protection system. – Type: “ JY67FF” (Tanker version)

Lifeboats IMO Resolution MSC.81(70) Part 1, as amended by resolution MSC 226(82) and MSC 274 (85). IMO MSC Circular 1006.

Expires: 15 December 2015

MED 1050355

Page 268: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

268 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jiangyin Wolong F.R.P Boat Co. Ltd ...continued

50 and 42 persons free-fall launched totally enclosed GRP lifeboat – Type: “ JY85CF” (Cargo Version)

Lifeboats IMO Resolution MSC.81(70) Part 1, as amended IMO MSC Circular 1006

Expires: 14 July 2021

MED 1650186

50 and 42 persons freefall launched, totally enclosed, GRP Lifeboat, with self-contained air support system and water spray fire protection system - Type: “ JY85FF” (Tanker Version)

Totally Enclosed Lifeboats IMO Resolution MSC.81(70) Part 1, as amended IMO MSC Circular 1006

Expires: 14 July 2021

MED 1650187

Jiangyinshi Beihai LSA Co., Ltd., 33# Beihuan Road, Yuecheng Town, Jiangyin City, Jiangsu Province, 214404, China, People's Republic of.

30 persons Free Fall Launched totally enclosed GRP Lifeboat w ith self-contained air support system and water spray fire protection system Type: “JYB66FF” (Tanker Version)

Lifeboats IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 19 August 2015

MED 1050236

30 persons Free Fall Launched totally enclosed GRP Lifeboat Type: “JYB66FC” ( Cargo version )

Lifeboats IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 19 August 2015

MED 1050237

Palfinger M arine Netherlands BV, Ambachtsweg 10, 3771 M G Barneveld, Barneveld, Netherlands, The.

90 Persons Davit Launched Totally Enclosed GRP Lifeboat – Type “ PN85C” (Cargo Version).

LIFEBOATS/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89). IMO MSC/ Circ. 1006.

Expires: 15 December 2019

MED 1450264

Page 269: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

269 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

90 Persons Davit Launched Totally Enclosed GRP Lifeboat – Type “ PN85 F” (Tanker Version).

LIFEBOATS/RESCUE BOAT

IMO Resolution MSC.81 (70), Part1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89). IMO MSC/ Circ. 1006

Expires: 15 December 2019

MED 1450265

150 Persons Davit Launched Totally Enclosed GRP Lifeboat – Type “ PN150C” (Cargo Version).

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89). IMO MSC/ Circ. 1006.

Expires: 18 March 2020

MED 1550058

150 Persons Davit Launched Totally Enclosed GRP Lifeboat – Type “ PN150 F” (Tanker Version).

LIFEBOATS IMO Resolution MSC.81 (70), Part1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89). IMO MSC/ Circ. 1006

Expires: 18 March 2020

MED 1550059

Page 270: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

270 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Palfinger M arine Netherlands BV ...continued

120 Persons Davit Launched Totally Enclosed GRP Lifeboat – Type “ PN95C” (Cargo Version).

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89). IMO MSC/ Circ. 1006.

Expires: 30 June 2020

MED 1550156

120 Persons Davit Launched Totally Enclosed GRP Lifeboat – Type “ PN95F” (Tanker Version).

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89). IMO MSC/ Circ. 1006

Expires: 30 June 2020

MED 1550157

42 Persons Free-Fall Lifeboats Totally Enclosed GRP Lifeboats Type: “PN90FC” (Cargo Version).

Lifeboats IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85) and MSC.323 (89). IMO MSC./ Circ. 1006

Expires: 2 September 2020

MED 1550218

42 Persons Free-Fall Lifeboats Totally Enclosed GRP Lifeboats Type: “PN90FF” (Tanker Version).

Lifeboats IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85) and MSC.323 (89). IMO MSC./ Circ. 1006

Expires: 2 September 2020

MED 1550219

66 Persons Davit Launched Totally Enclosed GRP Lifeboat – Type “ PN75 F” (Tanker Version)

LIFEBOATS/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89) IMO MSC/ Circ. 1006

Expires: 16 November 2020

MED 1550253

66 Persons Davit Launched Totally Enclosed GRP Lifeboat – Type “ PN75 C” (Cargo Version)

LIFEBOATS/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89) IMO MSC/ Circ. 1006

Expires: 16 November 2020

MED 1550254

Page 271: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

271 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

45 Persons Davit Launched Totally Enclosed GRP Lifeboat – Type “PN58C” (Cargo Version)

LIFEBOATS/RESCUE BOAT IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC/ Circ. 1006

Expires: 4 January 2021

MED 1650001

45 Persons Davit Launched Totally Enclosed GRP Lifeboat – Type “PN58F” (Tanker Version)

LIFEBOATS/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC/ Circ. 1006

Expires: 4 January 2021

MED 1650002

Shanghai Jiangnan Boatbuilding Co., Ltd., No. 999 Hailong Road, Fengxian District, Shanghai, China, People's Republic of.

34 persons Fire-protected Free Fall Launched totally enclosed GRP Lifeboat-Type:”JN-75FF” (Tanker Version)

LIFEBOATS IMO Resolution MSC.81 (70) Part 1 as amended by MSC.218(82), MSC.226(82), MSC.323(89) and MSC.274 (85). IMO MSC./ Circular 1006.

Expires: 1 July 2019

MED 1450154

Page 272: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

272 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shigi Shipbuilding Co. Ltd, 3-36 Dejimanishi-machi, Sakaiku, Sakai-city, Osaka, 590-0831, Japan.

33 Person davit launched totally enclosed GRP lifeboat/ rescue boat – Type: “ SZ-65 BRS” (Cargo Version)

LIFEBOATS / RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by Res. MSC.218 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89). IMO MSC/ Circ. 1006

Expires: 8 April 2020

MED 1550066

25 Persons Free-Fall Lifeboat Totally Enclosed, FRP Lifeboat – Type: “FEL59” (Cargo Version)

Lifeboats IMO Resolution MSC.81 (70) Part 1 as amended by MSC.226 (82), MSC.274 (85) and MSC.323 (89) IMO MSC./ Circ. 1006

Expires: 27 October 2020

MED 1550279

30 persons Free Fall Launched totally enclosed FRP Lifeboat Type: “FEL66” ( Cargo version )

LIFEBOATS IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 24 October 2020

MED 1650054

50 Person davit launched totally enclosed GRP lifeboat / rescue – Type: “ SZ-80 BRS” (Cargo Version)

LIFEBOATS / RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC 226(82), MSC 274(85) and MSC 321(89). MSC Circular 1006.

Expires: 4 August 2021

MED 1650204

45 persons Davit launched totally enclosed GRP lifeboat/ rescue boat w ith self-contained air support system and a fire protection system – Type: “ SZ-80 TRS” (Tanker Version)

LIFEBOATS / RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85) and MSC.321 (89). MSC Circular 1006.

Expires: 4 August 2021

MED 1650205

30 persons davit launched totally enclosed GRP lifeboat / rescue boat with a self contained air support system and with fire protection system, Tanker Version – Type: “ SZ-65 TRS”

LIFEBOATS / RESCUE BOATS IMO Resolution MSC.81(70), Part 1. MSC Circular 1006.

Expires: 9 March 2022

MED 1750043

Page 273: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

273 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

25 Person davit launched totally enclosed GRP lifeboat / rescue boat – Type: “ SZ-53 BR”

LIFEBOATS / RESCUE BOATS IMO Resolution MSC.81(70), Part 1. MSC Circular 1006.

Expires: 11 April 2022

MED 1750066

25 Person davit launched totally enclosed GRP Lifeboat / Rescue boat w ith self-contained air support system and fire protection system – Type: “ SZ-53 TR”

LIFEBOATS / RESCUE BOATS IMO Resolution MSC.81(70), Part 1. MSC Circular 1006.

Expires: 11 April 2022

MED 1750067

Page 274: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

274 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Survival Craft Inspectorate Ltd, Findon Shore, Findon, Aberdeen, AB12 3RL, United Kingdom (UK).

86 Person Davit launched totally enclosed GRP lifeboat – Type: “ SC93C” (Cargo version)

LIFEBOATS

IMO Resolution MSC.81 (70), Part 1 as amended by MSC 226 (82), MSC 274 (85) and MSC.321 (89)

Expires: 28 September 2014

MED 0950261/ M1

72 Person Davit launched totally enclosed GRP lifeboat – Type: “SC86C” (Cargo version)

Lifeboat/ Rescue Boats IMO Resolution MSC.81(70), Part 1 as amended by MSC 226 (82) and MSC 274 (85) IMO MSC/ Circ. 1006

Expires: 1 August 2015

MED 1050190

86 Person Davit launched totally enclosed GRP lifeboat w ith self-contained air support system and water spray fire protection system. – Type: “ SC93F” (Tanker version)

LIFEBOATS

IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89). IMO MSC/ Circ. 1006.

Expires: 13 January 2020

MED 1550013

72 Person Davit launched totally enclosed GRP lifeboat w ith self-contained air support system and water spray fire protection system. – Type: “SC85FA” (Tanker version)

Lifeboat/ Rescue Boats IMO Resolution MSC.81(70), Part 1 as amended by MSC 226 (82) and MSC 274 (85) IMO MSC/ Circ. 1006

Expires: 17 July 2021

MED 1650192

Umoe Schat-Harding Boatbuilding (Qingdao) Co. Ltd., Hetao Port, Chengyang District, Qingdao, 266113, China, People's Republic of.

31 persons davit launched / totally enclosed GRP Lifeboat/ Lifeboat-Rescue Boat w ith self-contained air support system and water spray fire protection system - Type: “22TECB” (Tanker Version)

LIFEBOAT/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85) and MSC.321 (89). IMO MSC Circular 1006

Expires: 29 August 2016

MED 1150242/ M2

Page 275: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

275 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

25 person davit launched totally enclosed GRP Lifeboat/ Rescue Boat – Type: “20 TECB” (Cargo version)

LIFEBOATS/RESCUE BOAT IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85) and MSC.321 (89). IMO MSC Circular 1006

Expires: 22 September 2018

MED 1350120

38 person davit launched totally enclosed GRP lifeboat/ lifeboat-rescue boat w ith a self-contained air support system and a fire protection system - Type: "24 TECB - Tanker version"

LIFEBOAT/ RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85), MSC.321 (89) IMO MSC Circular 1006

Expires: 3 June 2021

MED 1650238

Page 276: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

276 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Umoe Schat-Harding Boatbuilding (Qingdao) Co. Ltd. ...continued

38 person davit launched totally enclosed GRP lifeboat/ lifeboat-rescue boat - Type: "24 TECB - Cargo version"

LIFEBOAT/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85), MSC.321 (89) IMO MSC Circular 1006

Expires: 3 June 2021

MED 1650239

31 Person davit launched / totally enclosed GRP Lifeboat / Lifeboat-Rescue Boat - Type: “ 22TECB“ (Cargo Version)”

LIFEBOAT/ RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85) and MSC.321 (89) IMO MSC Circular 1006

Expires: 22 December 2021

MED 1650297

Umoe Schat-Harding Equipment AS., N-5470 Rosendal, Norway.

70 person free fall totally enclosed GRP lifeboat w ith self-contained air support system and water spray fire protection system. – Type: “ FF1200S” (Tanker version)

LIFEBOATS

IMO Resolution MSC.81(70), Part 1 as amended by MSC.218(82), MSC.226(82) and MSC.274(85) IMO MSC/ Circ.1006 NMD853

Expires: 20 May 2015

MED 1050120

60 person free-fall totally enclosed GRP lifeboat with a self-contained air support system and with a fire protection system - Type “ FF 1000S M 2”

Lifeboats IMO Resolution MSC.81(70) Part 1 as amended by Resolution MSC 226(82) and MSC 274(85) IMO MSC/ Circ. 1006

Expires: 25 October 2015

MED 1050297

150 person davit launched partially enclosed GRP Lifeboat - Type: “ M PC 32”

Lifeboats IMO Resolution MSC.81(70), Part 1 as amended by Resolution MSC 226(82) and MSC 274(85). MSC. Circular 1006.

Expires: 7 December 2015

MED 1050371/ M1

Page 277: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

277 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

40 person davit launched totally enclosed GRP lifeboat/ rescue boat w ith a self contained air support system and a water spray fire protection system – Type: “ MCBO24” (Tanker Version)

A.1/ 1.17 LIFEBOATS A.1/ 1.18 RIGID RESCUE BOATS

IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 9 May 2017

MED 1250082

50 person davit launched totally enclosed GRP lifeboat/ rescue boat – Type: “ MCB 24C” (Passenger vessel only)

Lifeboats/ Rigid Rescue Boats IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) IMO MSC./ Circular 1006

Expires: 14 May 2017

MED 1250089

50 person davit launched totally enclosed GRP lifeboat/ rescue boat w ith self-contained air support and fire protection system – Type: “KISS 700” (Tanker Version)

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC Circular 1006

Expires: 18 July 2021

MED 1650193

Page 278: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

278 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Umoe Schat-Harding Equipment AS. ...continued

50 person davit launched totally enclosed GRP lifeboat/ rescue boat - Type: “ KISS 700” (Cargo Version)

LIFEBOATS IMO Resolution MSC.81 (70), Part 1 as amended by resolution MSC.218 (82), MSC.226 (82), MSC.274 (85), MSC.323 (89) and MSC.321 (89) IMO MSC Circular 1006 IMO MSC.1/ Circ 1393

Expires: 27 February 2017

MED 1250022/ M1

Vanguard (Nantong) F.R.P Co. Ltd, Tongzhou City, Sanyu Town, Nantong, Jiangsu Province, 226331, China, People's Republic of.

85 persons davit launched totally enclosed GRP Lifeboat / Rescue Boat - Type: “VG8.5C” (Cargo version)

LIFEBOAT/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by Res. MSC.218 (82), MSC.226 (82), MSC.274 (85) and MSC.321 (89). MSC Circular 1006.

Expires: 16 December 2018

MED 1350159

85 persons totally enclosed GRP Lifeboat/ rescue boat w ith self contained air support system and water spray fire protection system - Type: “VG8.5F” (Tanker version)

LIFEBOAT/RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by Res. MSC.218 (82), MSC.226 (82), MSC.274 (85) and MSC.321 (89) MSC Circular 1006

Expires: 16 December 2018

MED 1350160

Verhoef Aluminium Scheepsbouw Industrie BV, PO Box 260, 1430 AG Aalsmeer, Netherlands, The.

45 person freefall totally enclosed FRP lifeboat w ith a self-contained air support system and with a fire protection system – Type: “ FL-50”

Freefall Lifeboat SOLAS 74 as amended, Regulations III/ 4 and 34. The LSA Code, Regulations I/ 1.2, IV/ 4.4, 4.6, 4.7, 4.8 and 4.9. IMO Resolution MSC.81(70), Part 1.

Expires: 13 September 2017

MED 1250165

Verhoef Aluminium Scheepsbouw Industrie BV, M olenweg 125, 1436 BS Aalsmeerderbrug, Netherlands, The.

70 Persons freefall totally enclosed Aluminium lifeboat w ith a self-contained air system and with a fire protection system – Type “ FL75” .

LIFEBOAT IMO Resolution MSC.81 (70) Part 1, as amended by MSC.200 (80), MSC.226 (82), MSC.274 (85), MSC.295 (87) & MSC.321 (89).

Expires: 13 February 2019

MED 1450034

Page 279: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.17a LIFEBOATS - DAVIT - LAUNCHED LIFEBOATS - PARTIALLY ENCLOSED/TOTALLY ENCLOSED

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

279 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wuxi Wenjiao GFRP Factory, Hong Xi cun, Hongsheng town, Wuxi City, Jiangsu, 214115, China, People's Republic of.

30 person Free fall launched totally enclosed GRP lifeboat - Type: “ WJ67FC” (Cargo Version)

Lifeboats IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 12 March 2017

MED 1250033

30 person Free Fall launched totally enclosed GRP lifeboat w ith self contained air support system and water spray system- Type: “ WJ67FF” (Tanker Version)

Lifeboats IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC.274(85) IMO MSC./ Circular 1006

Expires: 12 March 2017

MED 1250034

Page 280: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.18 RIGID RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

280 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

CSSC Luzhou M achine Zhenjiang M arine Auxiliary M achinery Co, 56# Yuehe Street,, Jianbi Town, Zhenjiang City,, Jiangsu Province, 212006, China, People's Republic of.

6 person FRP Rescue Boat Type “ YH4.5R (C Type)”

RIGID RESCUE BOATS IMO Resolution MSC.81(70), Part 1 as amended IMO MSC/ Circular 1006

Expires: 4 May 2022

MED 1750081

HLB CO., Ltd., 272-12, Dangwol-ro, Onsan-Eup, Ulju-Gun, Ulsan, 689-892, Korea, Republic of.

6 person single fall davit launched rigid Rescue Boat w ith inherent buoyancy, powered by “ HB29D1 29 HP” and “ HB23D1 23 HP” inboard diesel engine - Type “ HDR475”

RIGID RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82) and MSC.274 (85). IMO MSC./ Circular 1006

Expires: 24 May 2017

MED 1250093/ M2

Jiangyin Neptune M arine Appliance Co. Ltd, 25# North Road, Yuecheng Town, Jiangyin City, Jiangsu Province, China, People's Republic of.

6 person single fall davit launched rigid Rescue Boat w ith inherent buoyancy – Type: “ NPT 45R ”

Rigid Rescue Boats IMO Resolution MSC.81 (70), Part 1 as amended by as amended by MSC.226 (82) and MSC.274(85). IMO MSC./ Circular 1006

Expires: 8 August 2015

MED 1050197

Jiangyin Wolong F.R.P Boat Co. Ltd, Yuecheng Town, Jiangyin City, Jiangsu, 214404, China, People's Republic of.

8 persons single fall davit launched rigid rescue boat w ith inherent external buoyancy, powered by an 25/ 30HP outboard engine – Type: “ JY40KR”

Rescue Boats IMO Resolution MSC.81 (70) Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89). IMO MSC/ Circ. 1006.

Expires: 13 February 2016

MED 1150061/ M1

Page 281: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.18 RIGID RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

281 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jiangyinshi Beihai LSA Co., Ltd., 33# Beihuan Road, Yuecheng Town, Jiangyin City, Jiangsu Province, 214404, China, People's Republic of.

6 person single fall davit launched rigid Rescue Boat w ith inherent buoyancy Type “ SC45KR”

Rigid Rescue Boats IMO Resolution MSC.81 (70), Part 1 as amended by as amended by MSC.226 (82) and MSC.274(85). IMO MSC./ Circular 1006

Expires: 27 September 2015

MED 1050266

Palfinger Boats, Pasteurdijk 8, 3846BS Harderwijk, Netherlands, The.

6 Persons davit launched Rigid Rescue Boat – Type “FRSQ 600G SID”

Rigid Rescue Boat IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89) IMO MSC/ Circ. 1006

Expires: 3 February 2021

MED 1650059

Page 282: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.18 RIGID RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

282 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Palfinger Boats ...continued 6 person single fall davit launched rigid Rescue Boat– Type: “ RSQ 450 G”

Rigid Recue Boats IMO Resolution MSC.81 (70), Part 1 as amended by as amended. IMO MSC./ Circular 1006.

Expires: 10 October 2021

MED 1650252

Shanghai Jiangnan Boatbuilding Co., Ltd., No. 999 Hailong Road, Fengxian District, Shanghai, China, People's Republic of.

6 person single fall davit launched rigid Rescue Boat w ith inherent buoyancy – Type: “ JN-45KR”

RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82) and MSC.274(85). IMO MSC./ Circular 1006

Expires: 19 May 2016

MED 1150148

Shigi Shipbuilding Co. Ltd, 3-36 Dejimanishi-machi, Sakaiku, Sakai-city, Osaka, 590-0831, Japan.

6 persons Rigid Rescue Boat launched by single point lift arrangement – Type: “VOX 46”

Rescue Boats IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC 226(82) and MSC 274(85) IMO MSC Circular 1006

Expires: 30 June 2015

MED 1050235

Stocznia Ustka Sp. z.o.o., 1, Westerplatte St., 76-270 Ustka, Poland.

6 Persons davit launched Rigid Rescue Boat – Type “R44-II I”

RESCUE BOAT IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89) IMO MSC/ Circ. 1006

Expires: 2 November 2020

MED 1550075

Umoe Schat-Harding Equipment AS., N-5470 Rosendal, Norway.

6/ 12 persons davit-launched Rigid Rescue Boat, outboard powered (w ith 30 hp engine) - Type: “ Stinger 630 OB”.

RESCUE BOATS IMO Res. MSC.81 (70) as amended by MSC.226 (82) and MSC.274 (85). IMO MSC/ Circular 1006

Expires: 21 December 2015

MED 1050357/ M1

Page 283: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.18 RIGID RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

283 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wuxi Wenjiao GFRP Factory, Hong Xi cun, Hongsheng town, Wuxi City, Jiangsu, 214115, China, People's Republic of.

6 persons single fall davit launched rigid Rescue Boat w ith inherent buoyancy powered by an HP outboard engine - Type: “ WJ45KR”

A.1/ 1.18 - Rigid Rescue Boats IMO Resolution MSC.81 (70) Part 1 as amended to date.

Expires: 30 June 2019

MED 1450149

Zhenjiang M arine Auxiliary M achinery Works, CSSC Nanjing Luzhou M achine Co., Ltd, 56 Yuehe Street, Jianbi, Zhenjiang, Jiangsu, 212006, China, People's Republic of.

6 person single fall davit launched Rigid Rescue Boat w ith inherent buoyancy Type “ YH4.5R”

RIGID RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85) & MSC.321 (89). IMO MSC./ Circular 1006

Expires: 11 September 2018

MED 1350121/ M1

6 Person single fall davit launched Rigid Rescue Boat w ith inherent buoyancy – Type: “ YH4.5DR” .

RIGID RESCUE BOAT IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85) & MSC.321 (89). IMO MSC. / Circular 1006.

Expires: 21 September 2019

MED 1450192

Page 284: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.20 FAST RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

284 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

BAE System M aritime Services SBCE - Halmatic Products, Building 3/236 - PP 112, M ilitary Road, HM Naval Base, Portsmouth, PO1 3NH, United Kingdom (UK).

Pacific 24 Mk IV Fast Rescue Boat RIGID/INFLATED FAST RESCUE BOAT

IMO Resolution MSC. 81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89).

O MSC/ Circ. 1006. ISO 15372 (2000).

Expires: 10 June 2019

MED 1450126/ M1

HLB CO., Ltd., 272-12, Dangwol-ro, Onsan-Eup, Ulju-Gun, Ulsan, 689-892, Korea, Republic of.

15 persons davit launched inboard powered rigid fast rescue boat – Type: “ HDFR 680”

Fast Rescue Boat IMO Resolution MSC.81(70), Part 1 as amended by MSC 226(82) and MSC 274(85) MSC Circular 1006.

Expires: 12 August 2020

MED 1550207

NarwhalBoatsSL, CaminoSerraaAuga, M osPontevedra, Spain.

Rigid/ Inflated Fast Rescue Boat Type – “ FRB 700” .

RIGID/ INFLATED FAST RESCUE BOAT

IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89).

O MSC/ Circ. 1006 ISO 15372.

Expires: 6 January 2020

MED 1550005

Palfinger Boats, Pasteurdijk 8, 3846BS Harderwijk, Netherlands, The.

6/ 15 persons davit-launched Rigid Fast Rescue Boat, powered w ith 90 hp single or tw in outboard engine - Type: “ FRSQ 600G SOB/TOB”

FAST RESCUE BOATS IMO Res. MSC.81 (70) as amended IMO MSC/ Circular 1006

Expires: 19 May 2021

MED 1650152

Palfinger M arine Netherlands BV, Ambachtsweg 10, 3771 M G Barneveld, Barneveld, Netherlands, The.

6/15 persons davit-launched Rigid Fast Rescue Boat, outboard and inboard engine – Type “PN60RA/RB”.

FAST RESCUE BOAT IMO Res. MSC.81 (70) as amended by MSC.226 (82), MSC.274 (85), MSC. 323 (89) & MSC.321 (89). IMO MSC/ Circ. 1006.

Expires: 15 December 2019

MED 1450263

Page 285: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.20 FAST RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

285 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Rafnar ehf, Vesturvör 32b, 200 Kópavogur, Iceland.

8,5m Fast Rescue Boat: Type” Flengur 850”

RIGID – INFLATED FAST RESCUE BOAT

IMO Resolution MSC.81(70), Part 1 as amended by Resolution MSC.226(82), MSC.274(85),MSC.321(89) and MSC.323(89) MSC/ Circ. 1006 ISO 15372 (2000)

Expires: 16 November 2021

MED 1650277

Umoe Schat-Harding Equipment AS., N-5470 Rosendal, Norway.

6/ 12 persons Water Jet propelled Fast Rescue Boat – Type: Stinger 630 Jet

FAST RESCUE BOATS

IMO Resolution MSC.81(70) as amended by MSC.226(82) and MSC.274(85) IMO MSC/ CIRCULAR 1006

Expires: 16 May 2015

MED 1050113

Page 286: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.20 FAST RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

286 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Umoe Schat-Harding Equipment AS. ...continued

6/ 12 persons davit-launched Rigid Fast Rescue Boat, outboard powered (w ith 90 hp engine) - Type: “ Stinger 630 OB”

FAST RESCUE BOATS IMO Res. MSC.81 (70) as amended IMO MSC/ Circular 1006

Expires: 21 December 2020

MED 1650141

Work Ribs Holland BV, Het Nieuwe Werk 40, 1781 AL Den Helder, Netherlands, The.

15 person davit launched outboard powered rigid inflated fast rescue boat – Type: “ WRH 635 FRB”

RIGID – INFLATED FAST RESCUE BOAT

IMO Resolution MSC.81(70), Part 1 as amended by Resolution MSC.226(82), MSC.274(85),MSC.321(89) and MSC.323(89) MSC/ Circ. 1006 ISO 15372 (2000)

Expires: 17 October 2021

MED 1650208/ M1

9 person davit launched inboard powered jet propulsion rigid inflated fast rescue boat, Type: “ WRH 625 FRB”

RIGID-INFLATED FAST RESCUE BOAT

IMO Resolution MSC. 81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85) MSC.323 (89) & MSC.321 (89), IMO MSC/ Circ. 1006 ISO 15372 (2000)

Expires: 4 December 2021

MED 1650290

Zodiac Hurricane Technologies Inc., 7830 Vantage Way, Delta, British Columbia, V4G 1A7, Canada.

6 persons inboard/ outdrive powered davit-launched rigid/ inflated rescue boat - Type: “ H638 PROLUX”

RIGID/INFLATED RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by IMO Resolution MSC. 226(82), MSC.274 (85), MSC.323 (89) and MSC.321 (89). IMO MSC/ CIRC.1006 ISO 15372:2000

Expires: 10 December 2018

MED 1350161/ M1

6 Persons davit launched rigid/ inflated fast rescue boat – Type “H638 DJ & H638 IO”

RIGID/INFLATED FAST RESCUE BOATS

IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82), MSC.274 (85) MSC.323 (89) & MSC.321 (89) IMO MSC/ Circ. 1006 ISO 15372:2000

Expires: 14 October 2020

MED 1550240/ M2

Page 287: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.20 FAST RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

287 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fast Rescue Boat, Type “ H749” RIGID-INFLATED FAST RESCUE BOAT

IMO Resolution MSC. 81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89) ISO 15372 (2000)

Expires: 19 May 2021

MED 1650151

Zodiac M ilpro UK Limited, Dafen, Llanelli, Carmarthenshire, SA14 8NA, United Kingdom (UK).

Rescue Boat Type: “ Searider 6M” ; 6 persons rigid-inflated Fast Rescue Boat w ith external inflated buoyancy , powered by two Mariner 60 outboard engines

A.1/1.20 - Fast Rescue Boats A.1/1.43 - Rigid/Inflated Rescue Boats

IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 226(82), MSC 274(85) and MSC 323(89). MSC/ Circ 1006 ISO 15372 (2000)

Expires: 30 July 2019

MED 1450165

Page 288: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.21 LAUNCHING APPLIANCES USING FALLS (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

288 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

CSSC Nanjing Luzhou M achine Co., Ltd, Zhenjiang M arine Auxiliary M achinery Works, #56 Yuehe Street, Jianbi Town, Zhenjiang City, Jiangsu Province, 212006, China, People's Republic of.

Pivoted single arm davit for survival craft and rescue boat type HDCL2-6.5 using fall, w ith approved hydraulic powered w inch -Type: “ HDCL2-6.5”

Davits for Survival Craft/ Rescue Boats IMO Resolution MSC.81(70) Part 1 Expires: 6 December 2016

MED 1150319

Gravity luffing double arm lifeboat davit using two falls: Type: “LE55-1”

DAVIT IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 10 January 2022

MED 1750006

d-i davit international gmbh, Sandstrasse 20, 27232 Sulingen, Germany.

Launching Appliances Using Falls (Davits)

Single telescopic arm gravity Davit for Rescue Boat – Type – “ D-TT.SP.20”

IMO Resolution MSC.81(70), Part 1.

Expires: 31 January 2015

MED 1050028

Single Drum Electric Rescue Boat Winch – Type: “ 04.25”

Launching appliances using fall and w inch

IMO Resolution MSC.81(70), Part 1

Expires: 11 August 2015

MED 1050214

Harding Safety AS, Seimsvegen 116, 5472 Seimsfoss, Norway.

Launching Appliance for Lifeboat Type: “ VIP23FDL” .

LAUNCHING APPLIANCE USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 1 July 2019

MED 1450153/ M1

Launching Appliance for Lifeboat Type: “VIP24FD”

LAUNCHING APPLIANCE USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 14 August 2019

MED 1450170

Harding Safety AS, 5472 Seimsfoss, Norway.

Fixed double arm gravity lifeboat using two falls – Type: “ FAD 1000.1” .

LAUNCHING APPLIANCES USING FALLS (DAVIT)

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 7 April 2020

MED 1550076/ M1

Page 289: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.21 LAUNCHING APPLIANCES USING FALLS (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

289 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jiangyin Neptune M arine Appliance Co. Ltd, 25# North Road, Yuecheng Town, Jiangyin City, Jiangsu Province, China, People's Republic of.

Platform Lifeboat davit using two falls – Type: “ NPT 138DP”

Platform Lifeboat Davit IMO Resolution MSC.81 (70), Part 1 Expires: 17 August 2015

MED 1050239

Gravity Luffing Arm Davit for Lifeboat/ rescue boat using two falls – Type: “ NPT 60DL”

Davits for Survival Craft/ Rescue Boats IMO Resolution MSC.81 (70), Part 1 as amended by Resolution MSC.226(82) and MSC.274(85)

Expires: 31 January 2016

MED 1150049/ M1

Page 290: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.21 LAUNCHING APPLIANCES USING FALLS (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

290 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jiangyin Neptune M arine Appliance Co. Ltd ...continued

Twin fall gravity luffing pivot davits for the launch and recovery of lifeboats and Lifeboat/ rescue boats – Type “ NPT 138DL”

DAVITS FOR SURVIVAL CRAFT/RESCUE BOATS

IMO Resolution MSC.81 (70), Part 1 Expires: 9 December 2019

MED 1550231

Jiangyin Wolong F.R.P Boat Co. Ltd, Yuecheng Town, Jiangyin City, Jiangsu, 214404, China, People's Republic of.

Gravity Luffing Arm Davit for lifeboat/ rescue boat using two falls Type “ JY-LE65”

Launching Appliances IMO Resolution MSC.81(70), Part 1 as amended by MSC.226 (82) and MSC. 274 (85).

Expires: 20 March 2017

MED 1250048

M ontmontaza-Greben d.o.o., 20270 Vela Luka, Obala 4, br.50, Croatia.

Fixed single arm electro-hydraulic stored energy slewing rescue boat/ liferaft davit using one falls – Type: “ Greben RC 12/ 3.3”

Davits For Survival Craft/ Rescue Boats

IMO Resolution MSC.81(70), Part 1

Expires: 8 May 2015

MED 1050246

Fixed single arm electro-hydraulic stored energy slewing rescue boat/ liferaft and means of rescue davit using one falls – Types: “ Greben RLC 14/ 3.3

Davits For Survival Craft/ Rescue Boats

IMO Resolution MSC.81(70), Part 1 Expires: 8 May 2015

MED 1050247/ M1

Ned-Deck M arine b.v., Ambachtsweg 10, 3771 M G Barneveld, Netherlands, The.

Roller track, double arm, stored energy/ gravity lifeboat davit using two falls- Type “ HT3-240”

Launching Appliances IMO Resolution MSC.81 (70) Part 1, as amended by MSC.226 (82) and MSC. 274 (85).

Expires: 12 May 2015

MED 1050112

Page 291: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.21 LAUNCHING APPLIANCES USING FALLS (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

291 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Palfinger M arine Netherlands BV, Ambachtsweg 10, 3771 M G Barneveld, Barneveld, Netherlands, The.

Launching Appliance Type – PFH 230 LAUNCHING APPLIANCE USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended

Expires: 20 February 2019

MED 1450040/ M1

Launching Appliance for Rescue Boat Type – PRH35 AP (27.5)

LAUNCHING APPLIANCE USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended

Expires: 24 February 2019

MED 1450042/ M1

Launching Appliance for Rescue Boat Type–SCH 15-4.0 R & SCH 15-4.0 (3.5 m) R

LAUNCHING APPLIANCE USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended

Expires: 2 April 2019

MED 1450075/ M1

Launching Appliance for Lifeboat & Rescue Boat Type: “FPG 85-2 (L) & FPG 85-2(R)”.

LAUNCHING APPLIANCE USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 12 June 2019

MED 1450129/ M1

Launching Appliance for Rescue Boat Type – “PRHE 35 H”.

LAUNCHING APPLIANCE USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 18 August 2019

MED 1450171/ M1

Page 292: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.21 LAUNCHING APPLIANCES USING FALLS (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

292 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Palfinger M arine Netherlands BV ...continued

Launching Appliance for Rescue Boat Type–SCH 12-3.5 R-LV

LAUNCHING APPLIANCE USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended

Expires: 9 October 2019

MED 1450221/ M1

Single Arm Davit for Rescue Boat and Liferaft Type – SCH23/ 17-4.0 LR

LAUNCHING APPLIANCE IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 22 October 2019

MED 1450226/ M1

Launching Appliance for Rescue Boat Type – “ PRHE 25-2” .

LAUNCHING APPLIANCE USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 16 December 2019

MED 1450262/ M2

Launching Appliance for Rescue Boat Type – “ PRHE 25H-2” .

LAUNCHING APPLIANCE USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 31 May 2020

MED 1550135/ M1

Single Arm Davit for Rescue Boat Type – SCH 17-4.0 R

LAUNCHING APPLIANCE IMO Resolution MSC.81 (70), Part 1 as amended.

Expires: 12 August 2020

MED 1550203/ M1

Survitec Survival Craft, Findon Shore, Findon, Aberdeen, AB12 3RL, United Kingdom (UK).

Single Fall Lifeboat Davit – Type: ” Single Fall”

LAUNCHING APPLIANCES USING FALLS (DAVITS)

IMO Resolution MSC.81(70), Part 1 Expires: 21 September 2020

MED 1550221/ M2

Umoe Schat-Harding BV, P.O. Box 337, 3990 GC Houten, Wilgenkade 17-19, 3992 LL Houten, Netherlands, The.

Manual Liferaft w inch – Type: “ 0-13-03”

WINCHES FOR SURVIVAL CRAFT AND RESCUE BOATS

IMO Resolution MSC.81(70) Part 1 Expires: 8 December 2020

MED 1550278

Umoe Schat-Harding Equipment AS., N-5470 Rosendal, Norway.

Pivoted single arm rescue boat davit using single fall – Type: “ SA 3,5”

Launching Appliances IMO Resolution MSC.81(70), Part 1

Expires: 13 September 2015

MED 1050368

Page 293: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.21 LAUNCHING APPLIANCES USING FALLS (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

293 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Single Pivot, double arm stored power/ gravity lifeboat davit w ith approved electro-hydraulic powered w inch type “ W120L” , for combined Lifeboat & Tender. Type: “PD24DM ”

Launching Appliances IMO Resolution MSC.81(70), Part 1

Expires: 1 December 2016

MED 1150311

Pivoted single arm rescue boat davit using single fall – Type: “ SA 3,5-II”

Davits for Survival Craft/ Rescue Boats IMO Resolution MSC.81(70), Part 1 as amended

Expires: 1 March 2017

MED 1250028

Multi-pivot point double arm gravity lifeboat davit using tw in falls - Type: “VIP 700”

LAUNCHING APPLIANCES USING FALLS (DAVITS)

IMO Resolution MSC.81 (70), Part 1 as amended

Expires: 29 April 2018

MED 1350060

Page 294: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.21 LAUNCHING APPLIANCES USING FALLS (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

294 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Umoe Schat-Harding Equipment AS. ...continued

Multi-pivot point double arm lifeboat davit using two falls – Type: “VIP1000”

A.1/1.21 - LAUNCHING APPLIANCES USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended

Expires: 5 January 2021

MED 1650052

Welin Lambie Ltd, Britannia House, Old Bush Street, Brierley Hill, West M idlands, DY5 1UB, United Kingdom (UK).

Single arm manual slewing davit w ith w inch type “ LRW21A” , suitable for launching and recovery of liferafts - Type: “ SALD 2.1-4A” and “ SALD 1.8-4A”

LAUNCHING APPLIANCES USING FALLS (DAVITS)

IMO Resolution MSC.81 (70) as amended by MSC.274 (85)

Expires: 25 April 2015

MED 1050097/ M1

Wuxi Haitian M arine Equipment Co. Ltd, No. 7-1 Tianshi Road, Shitangwan, Wuxi City, China, People's Republic of.

Luffed Crane with electric powered motors for secondary means of launching and recovery of freefall lifeboats – Type: “ 248H/7.00.00”

Launching Appliances Using Falls (Davits)

IMO Resolution MSC.81(70), Part 1.

Expires: 7 July 2015

MED 1050167

Youngnam M arine M achinery Ind. Co., Ltd., #542-10, An Dong, Gimhae-city, Kyung Nam, 621-914, Korea, Republic of.

Fixed radius single arm manually slewed liferaft davit using a single fall - Type: “ YN-LRD-02-01”

DAVITS FOR SURVIVAL CRAFT IMO Resolution MSC.81 (70) Part 1 as amended

Expires: 9 August 2020

MED 1550238

Manually operated liferaft winch - Type: “ YN-LRW-02-01”

WINCHES FOR SURVIVAL CRAFT AND RESCUE BOATS

IMO Resolution MSC.81(70) Part 1 as amended.

Expires: 9 August 2020

MED 1550261

Page 295: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.21 LAUNCHING APPLIANCES USING FALLS (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

295 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Zhenjiang M arine Auxiliary M achinery Works, CSSC Nanjing Luzhou M achine Co., Ltd, 56 Yuehe Street, Jianbi, Zhenjiang, Jiangsu, 212006, China, People's Republic of.

Pivoted single arm davit for rescue boat/ life raft and free fall l ifeboat (secondary means of launching) using fall, lowering by gravity and slewing by stored energy – Type: “ HDCL4-5”

LAUNCHING APPLIANCES USING FALLS (DAVITS)

IMO Resolution MSC.81(70), Part 1.

Expires: 2 June 2015

MED 1050126

Page 296: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.23 LAUNCHING APPLIANCES FOR FREE-FALL LIFEBOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

296 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

CSSC Nanjing Luzhou M achine Co., Ltd, Zhenjiang M arine Auxiliary M achinery Works, #56 Yuehe Street, Jianbi Town, Zhenjiang City, Jiangsu Province, 212006, China, People's Republic of.

Free fall l ifeboat ( secondary means of launching ) Electric Winch – Type: “ HDC6-13”

Winches For Survival Craft IMO Resolution MSC.81(70), Part 1.

Expires: 25 May 2015

MED 1050364

Pivoted single arm davit for free fall l ifeboat (secondary means of launching) using fall, lowering by gravity and slewing by stored energy – Type: “ HDC6-13”

davits for survival craft IMO Resolution MSC.81(70), Part 1.

Expires: 25 May 2015

MED 1050365

Luffed crane w ith electric powered motors for secondary means of launching and recovery of freefall lifeboats – Type: “ EDC-7-10”

Launching Appliances IMO Resolution MSC.81(70), Part 1.

Expires: 6 January 2016

MED 1150004

Jiangyin Wolong F.R.P Boat Co. Ltd, Yuecheng Town, Jiangyin City, Jiangsu, 214404, China, People's Republic of.

Launching Appliances Inclined launching ramp designed for free-fall l ifeboat type JY59CF/ FF and JY49CF/ FF and provided w ith a secondary means of launching using an “ A” Frame – Type: “ JY-FH55”

IMO Resolution MSC.81(70) as amended by MSC 274(85) and MSC 226(82).

Expires: 15 February 2015

MED 1050041

Inclined launching ramp for free-fall l ifeboat type “ JY-FH70”

LAUNCHING APPLIANCES IMO Resolution MSC.81 (70), Part 1 as amended by Res. MSC.226 (82)

Expires: 29 September 2020

MED 1650023

Page 297: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.23 LAUNCHING APPLIANCES FOR FREE-FALL LIFEBOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

297 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Inclined launching ramp for free-fall l ifeboat Type - “ JY-FH90

LAUNCHING APPLIANCES IMO Resolution MSC.81 (70), Part 1 as amended by Res. MSC. 226 (82)

Expires: 8 May 2021

MED 1650142/ M1

Umoe Schat-Harding Equipment AS., N-5470 Rosendal, Norway.

Inclined launching ramp for free-fall l ifeboat type“ FF1200S” – Type: “ LA1200H ”

Launching Appliances IMO Resolution MSC.81(70), Part 1

Expires: 28 June 2015

MED 1050154

Inclined launching ramp for free-fall l ifeboat type“ FF1200S” – Type: “ LA1200HO”

Launching Appliances IMO Resolution MSC.81(70), Part 1

Expires: 28 June 2015

MED 1050155

Freefall launching ramp w ith secondary means of launching and recovery using A frame for free-fall l ifeboat type “ FF1000S M2” – Type: “ LA 1000H M2”

Launching Appliances IMO Resolution MSC.81(70), Part 1 as amended by resolution MSC 226(82) and MSC 274(85).

Expires: 1 December 2015

MED 1050338

Page 298: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.23 LAUNCHING APPLIANCES FOR FREE-FALL LIFEBOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

298 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wuxi Haidelong M arine Equipment Works, No. 63 Huanzhen West Road, Xida Bridge, Donghutang Town, Wuxi City, Jiangsu Province, 214196, China, People's Republic of.

FREE-FALL LAUNCHING APPLIANCE

Free-Fall Lifeboat Launching Appliance – Type: “ HDL70FA”

IMO Resolution MSC.81 (70), Part 1 as amended

Expires: 8 November 2017

MED 1250230

Wuxi Huahai M arine Equipment Factory, Jiangsu, Wuxi, Donggang Town 214196, China, People's Republic of.

Free-fall lifeboat launching appliance – Type: “HM D55F”

FREE-FALL LAUNCHING APPLIANCE

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 18 February 2019

MED 1450035

Page 299: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.24 LIFERAFTS LAUNCHING APPLIANCES (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

299 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Harding Safety Netherlands B.V., Wilgenkade 17-19, 3992 LL Houten, Netherlands, The.

Fixed single arm hand slewing liferaft davit – Type: “ SRR 360/ 3.65/ 21” and “ SRR 360/ 4/ 21”

Davits for Survival Craft IMO Resolution MSC.81(70), Part 1 Expires: 28 November 2015

MED 1050334

Palfinger M arine Netherlands BV, Ambachtsweg 10, 3771 M G Barneveld, Barneveld, Netherlands, The.

Single arm life raft davit – Type: “ PBR33”

DAVITS FOR LIFE RAFT IMO Resolution MSC.81 (70), Part 1 as amended to date.

Expires: 18 February 2019

MED 1450036/ M1

Umoe Schat-Harding BV, P.O. Box 337, 3990 GC Houten, Wilgenkade 17-19, 3992 LL Houten, Netherlands, The.

Davits For Survival Craft Fixed single arm hand slewing liferaft davit using one fall, w ith electric or manual recovery of empty hook - Type: “ SRR/ 75/ 4.4/ 30E” and “ SRR/ 75/ 4.4/ 30”

IMO Resolution MSC.81(70), Part 1

Expires: 27 June 2016

MED 1150183

Fixed single arm hand slewing liferaft davit using one fall – Types: SRR 360/ 3/ 21” & “ SRR 360/ 3/ 21E”

Davits For Liferaft IMO Resolution MSC.81(70), Part 1

Expires: 20 March 2017

MED 1250050

Fixed single arm hand slewing life raft davit – Type: “ SRR 360/ 3.65/ 23 and SRR 360/ 3.65/ 23E”

DAVITS FOR LIFE RAFT IMO Resolution MSC.81 (70), Part 1 as amended to date

Expires: 9 September 2018

MED 1350116/ M1

Welin Lambie Ltd, Britannia House, Old Bush Street, Brierley Hill, West M idlands, DY5 1UB, United Kingdom (UK).

Liferaft Launching Appliance Type – “ RD21-3.1A” .

LIFERAFT LAUNCHING APPLIANCES (DAVITS)

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 4 September 2019

MED 1450180

Page 300: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.24 LIFERAFTS LAUNCHING APPLIANCES (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

300 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wuxi Haidelong M arine Equipment Works, No. 63 Huanzhen West Road, Xida Bridge, Donghutang Town, Wuxi City, Jiangsu Province, 214196, China, People's Republic of.

Single Arm Davit For Rescue Boat & Liferaft – HDLD21

LAUNCHING APPLIANCES IMO Resolution MSC.81 (70), Part 1 as amended.

Expires: 8 November 2017

MED 1250232

Page 301: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.24 LIFERAFTS LAUNCHING APPLIANCES (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

301 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wuxi Huahai M arine Equipment Factory, Jiangsu, Wuxi, Donggang Town 214196, China, People's Republic of.

Single arm davit w ith stored power slewing and powered w inch type MW32, suitable for launching and recovery of liferafts - Type: “HM CD3/6.5”

DAVITS FOR LIFERAFTS IMO Resolution MSC.81(70) as amended.

Expires: 17 August 2020

MED 1550208

Page 302: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.25 FAST RESCUE BOAT LAUNCHING APPLIANCES (DAVITS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

302 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

d-i davit international gmbh, Sandstrasse 20, 27232 Sulingen, Germany.

Pivoted A-frame stored energy fast rescue boat davit – Type: “ D-NPS.FR.30”

LAUNCHING APPLIANCES IMO Resolution MSC.81(70) , Part 1 as amended

Expires: 2 August 2021

MED 1650201

Welin Lambie Ltd, Britannia House, Old Bush Street, Brierley Hill, West M idlands, DY5 1UB, United Kingdom (UK).

‘A ’ Frame Pivot Arm Davit for rescue boat - Type:” PIV1.0A”

Davits for Survival Craft/ Rescue Boats IMO Resolution MSC.81(70) , Part 1 as amended by Resolution MSC.226(82) and MSC.274(85)

Expires: 10 April 2016

MED 1150107

Page 303: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

303 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

BC Service Europe S.r.l., Via al M olo Giano sns, 16128 Genova, I taly.

“ On-Load/ Off-Load” twin fall simultaneous release mechanism for use with Lifeboats and Lifeboats/ Rescue Boats – Type “ U-Hook 15” .

RELEASE M ECHANISM IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.226 (82) and MSC.321 (89). UI SC 267 Rev.2.

Expires: 13 January 2020

MED 1550012/ M1

Bianchi & Cecchi Service Europe SRL, Via Al M olo Giano, Genova, 16128, I taly.

Single fall off-load 4.5 tonne SWL release mechanism for lifeboats and rescue boats – Type: “U-Hook 4,5 Off-Load”

RELEASE GEAR IMO Resolution MSC.81(70) Part 1

Expires: 22 March 2021

MED 1650099

Boatbuilding Branch, Qingdao Beihai Shipbuilding Industry Co. Ltd, #369 Lijiang East Road, Economic and Technical Development Zone, Qingdao, 266520, China, People's Republic of.

On-load/ Off-load Twin fall simultaneous release mechanism for use with lifeboat and lifeboat/ rescue boats – Type: “BHHOOK5”

RELEASE GEAR IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.226 (82) and MSC.321 (89)

Expires: 26 November 2017

MED 1350039

On-load release mechanism for free fall l ifeboat w ith maximum safe working load of 4.5 tonnes - Type: “ BG-4.5F”

c) Free Fall Lifeboats IMO Resolution MSC.81 (70), Part 1 as amended

Expires: 21 April 2021

MED 1650223

Page 304: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

304 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Boatbuilding Yard, Qingdao Beihai Shipbuilding Heavy Industry Co. Ltd, #369 Lijiang East Road, Economic and Technical Development Zone, Qingdao, 266520, China, People's Republic of.

On-load/ Off-load Twin fall simultaneous release mechanism for use with lifeboat and lifeboat/ rescue boats – Type: “BHHOOK3”

RELEASE GEAR IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82) and MSC.321 (89).

Expires: 29 November 2017

MED 1350036

CSSC Nanjing Luzhou M achine Co., Ltd, Zhenjiang M arine Auxiliary M achinery Works, #56 Yuehe Street, Jianbi Town, Zhenjiang City, Jiangsu Province, 212006, China, People's Republic of.

Lifeboat On-load/ Off-load Release Hook. Type “HK40(C)”

RELEASE GEAR IMO Resolution MSC.81 (70), Part 1 as amended MSC.226 (82) and MSC.321 (89)

Expires: 21 January 2021

MED 1650034

Harding Safety AS, Seimsvegen 116, 5472 Seimsfoss, Norway.

Centrally Operated ” On-Load/ Off-Load” Twin Fall Simultaneous Release Gear System Type: “ LHR6 M 2 and LHR 6 M 2 with Training Lock ”

RELEASE GEAR IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 226 (82) and MSC 321(89)

Expires: 17 April 2017

MED 1250066/ M2

Page 305: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

305 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Harding Safety AS ...continued

Centrally operated on-load/ off-load simultaneous release system with maximum safe working load of 12,000KG per hook – Type: “ LHR12 M2 and LHR12 M2 with Training Lock”

SIM ULTANEOUS RELEASE M ECHANISM FOR LIFEBOATS

IMO Resolution MSC.81 (70) Part 1 as amended by resolution MSC 226 (82) and MSC 321 (89)

Expires: 30 August 2017

MED 1250150/ M1

Centrally Operated “ On-Load/ Off-Load” Single Fall Release Gear System - Type: “ LHR6 M 2 and LHR6 M 2 with Training Lock”

RELEASE GEAR IMO Resolution MSC.81 (70) Part 1 as amended by resolution MSC.226 (82) and MSC.321 (89)

Expires: 30 January 2018

MED 1350005/ M2

Off-Load Single fall release gear system for rescue boat – Type: “ RH1,75L”

RELEASE M ECHANISM IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 226 (82) and MSC 321(89)

Expires: 25 June 2019

MED 1450146/ M1

Centrally Operated ” On-Load/ Off-Load” Twin Fall Simultaneous Release Gear System Type: “ LHR3.5 M 2 and LHR3.5M 2 with Training Lock ”

RELEASE M ECHANISM IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 226 (82) and MSC 321(89)

Expires: 23 November 2019

MED 1450250

Centrally Operated ” On-Load/ Off-Load” Single Fall Release Gear System Type: “ LHR3.5 M 2 and LHR3.5M 2 with Training Lock ”

RELEASE M ECHANISM IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 226 (82) and MSC 321(89)

Expires: 23 November 2019

MED 1450251

Harding Safety Netherlands B.V., Wilgenkade 17-19, 3992 LL Houten, Netherlands, The.

Off-Load/ On-Load lifeboat and rescue boat release gear using a single fall - Type: “ RRH 25”

Release Gear IMO Resolution MSC.81(70), Part 1.

Expires: 10 March 2015

MED 1050110

Page 306: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

306 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Off-Load/ On-Load lifeboat and rescue boat release gear using a single fall - Type: “ RRH 15”

Release Mechanism SOLAS 74 as amended, Regulations III/ 4 and 34. The LSA Code, Regulation IV/ 4.4.7.6. IMO Resolution MSC.81(70) Part 1.

Expires: 10 March 2010

MED 0550098

HLB CO., Ltd., 272-12, Dangwol-ro, Onsan-Eup, Ulju-Gun, Ulsan, 689-892, Korea, Republic of.

“ On-Load/ Off-Load” tw in fall simultaneous release hook for use w ith Lifeboats and Lifeboat/ Rescue Boat – Type: “ TALON II 4 .0” ( SWL : 4 ton per hook )

RELEASE GEAR IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 226 (82) and MSC 321(89)

Expires: 27 August 2017

MED 1250146

Page 307: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

307 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

HLB CO., Ltd. ...continued “ On-Load/ Off-Load” tw in fall simultaneous release hook for use w ith Lifeboats and Lifeboat/ Rescue Boat – Type: “TALON I I 6 .0” (SWL: 6 ton per hook).

RELEASE GEAR IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.226 (82) and MSC.321 (89).

Expires: 30 August 2017

MED 1250153/ M1

“ On-Load/ Off-Load” tw in fall simultaneous release hook for use w ith Lifeboats and Lifeboat/ Rescue Boat – Type: “TALON 9.0” (SWL: 9 ton per hook)

Release Gear IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 226 (82) and MSC 321(89)

Expires: 16 September 2021

MED 1650251

M ad Rock M arine Solutions Inc, 15 Hallett Crescent, Suite 201, St John's NL, A1B 4C4, Canada.

“ On-Load/ Off-Load” twin fall simultaneous release hook – Type: “ RocLoc 6 SWL 6 Ton

Release Gear IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82)

Expires: 3 September 2016

MED 1150228

M ontmontaza-Greben d.o.o., 20270 Vela Luka, Obala 4, br.50, Croatia.

Off-load/ On-load release hook for davit launched rescue boats using a single fall - Type “ NRH 2.5”

Release Mechanism IMO Resolution MSC.81(70),Part 1 as amended by MSC.226(82) .

Expires: 4 July 2015

MED 1050161

Centrally operated off-load/ on-load tw in fall simultaneous hook release gear system - Type: “ NLH-12”

Release Gear IMO Resolution MSC.81(70), Part 1 as amended by MSC 226(82).

Expires: 5 July 2015

MED 1050162

Norsafe AS, P.O. Box 115, N-4852 Faervik, Norway.

Off-Load only centrally operated release hook for davit launched rescue Boats using a single fall - Type: “ K4”

Release Gear IMO Resolution MSC.81(70), Part 1

Expires: 4 December 2015

MED 1050377

Page 308: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

308 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Palfinger M arine Netherlands BV, Ambachtsweg 10, 3771 M G Barneveld, Barneveld, Netherlands, The.

“ On-Load/ Off-Load” tw in fall simultaneous release mechanism for use w ith Lifeboats and Lifeboat/ Rescue Boats – Type “ PN65HKC” .

RELEASE MECHANISM IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.226 (82) and MSC.321 (89).

Expires: 11 November 2019

MED 1450247

Rescue Boat Manual Off-Load Release Mechanism Type “ PN30HK” .

RELEASE M ECHANISM IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.226 (82) and MSC.321 (89).

Expires: 18 November 2019

MED 1450252

“ On-Load/ Off-Load” tw in fall simultaneous release mechanism for use w ith Lifeboats and Lifeboat/ Rescue Boats – Type “ PN105KC” .

RELEASE M ECHANISM IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.226 (82) and MSC.321 (89).

Expires: 8 March 2020

MED 1550056

Page 309: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

309 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Palfinger M arine Netherlands BV ...continued

“ On-Load/ Off-Load” tw in fall simultaneous release mechanism for use w ith Lifeboats and Lifeboat/ Rescue Boats – Type “ PN85HKC” .

RELEASE MECHANISM “ On-Load/ Off-Load” tw in fall simultaneous release mechanism for use w ith Lifeboats and Lifeboat/ Rescue Boats – Type “ PN85HKC” .

Expires: 23 June 2020

MED 1550148

“ On-Load/ Off-Load” twin fall simultaneous release mechanism for use with Lifeboat and Lifeboat/ Rescue Boats – Type “PN35HKC”

RELEASE M ECHANISM IMO Resolution MSC.81 (70), Part 1 as amended by Resolution MSC.226 (82) and MSC. 321 (89).

Expires: 22 December 2020

MED 1550299

Shigi Shipbuilding Co. Ltd, 3-36 Dejimanishi-machi, Sakaiku, Sakai-city, Osaka, 590-0831, Japan.

Off-load/ on-load centrally operated hook release system for davit launched lifeboats and rescue boats using two falls - Type: “ SZK-30”

Release Mechanism IMO Resolution MSC.81(70), Part 1 as amended by MSC 226(82).

Expires: 6 March 2015

MED 1050182

Survitec Group, Kingsway, Dunmurry, Belfast, BT17 9AF, Northern Ireland.

Single fall off-load 5.0 tonne SWL release hook for lifeboats and rescue boats – Type: “RFD M k 6A”

Release Gear IMO Resolution MSC.81(70) Part 1 Expires: 19 December 2015

MED 1050367

Rescue boat single fall Off-Load release mechanism with automatic release facility. Type: “ RFD Automatic Release Hook Mk. 5” .

RELEASE MECHANISM FOR RESCUEBOAT

IMO Resolution MSC.81 (70) Part 1.

Expires: 25 November 2017

MED 1250243

Survival Craft Inspectorate Ltd, Findon Shore, Findon, Aberdeen, AB12 3RL, United Kingdom (UK).

“ On-load/ Off-load” tw in falls, simultaneous release hook. Type: “RocLoc 12”

Release Mechanism For Lifeboats IMO Resolution MSC.81(70), Part 1

Expires: 30 September 2015

MED 0750194/ M3

Page 310: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

310 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

“ On-Load/ Off-Load” Twin fall simultaneous release mechanism for use w ith lifeboats and lifeboat/ rescue boats. Type: “ RocLoc 13”

RELEASE MECHANISM FOR LIFEBOATS

IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82)

Expires: 25 November 2017

MED 1250238

Survival Systems International, Inc., 34140 Valley Center Road, Valley Center, CA. 92082, United States of America (USA).

“ On-Load/ Off-Load” tw in fall/ simultaneous hook release gear system - Type: “ Triple 5 Model TF555-111-15”

RELEASE GEAR IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 226 (82)

Expires: 8 May 2017

MED 1250081

Page 311: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

311 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Umoe Schat-Harding Equipment AS., N-5470 Rosendal, Norway.

Centrally operated on-load/ off-load simultaneous release system with a maximum safe working load of 12,000 Kg per hook – Type: “ LHR12.”

Simultaneous release mechanism for lifeboats

IMO Resolution MSC.81(70),Part 1 as amended by MSC.226(82).

Expires: 2 February 2015

MED 1050031

Release Gear For Free Fall Lifeboats Hydraulically operated on-load release mechanism for free fall l ifeboat w ith maximum safe working load of 15 tonnes - Type: “ FFH 15”

IMO Resolution MSC.81(70), Part 1

Expires: 7 March 2015

MED 1050057

Hydraulically operated on-load release mechanism for free fall l ifeboat w ith maximum safe working load of 25 tonnes - Type: “ FFH 25”

RELEASE GEAR FOR FREE FALL LIFEBOATS

IMO Resolution MSC.81(70), Part Expires: 8 March 2015

MED 1050058

Centrally Operated ” On-Load/ Off-Load” Twin Fall Simultaneous Release Gear System - Type: “ LHR9M2”

Release Gear IMO Resolution MSC.81(70) Part 1.

Expires: 3 May 2015

MED 1050099

Centrally operated on-load/ off-load simultaneous release system with maximum safe working load of 12,000Kg per hook – Type: “ LHR12M2”

Simultaneous Release Mechanism For Lifeboats

IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82)

Expires: 13 July 2015

MED 1050170/ M1

Single fall off-load release mechanism for fast rescue boats - Type: “ RH3.7”

Release Gear IMO Resolution MSC.81(70) Part 1 Expires: 22 November 2015

MED 1050330

Off-Load lifeboat and rescue boat release gear using a single fall - Type: “ RH 1.5“

Release Gear IMO Resolution MSC.81(70), Part 1.

Expires: 15 February 2016

MED 1150072

Page 312: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

312 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Centrally Operated ” On-Load/ Off-Load” Twin Fall Simultaneous Release Gear System - Type: “ LHR9M2 with training lock”

Release Gear IMO Resolution MSC.81(70) Part 1.

Expires: 6 March 2016

MED 1150079

RELEASE GEAR Centrally Operated “ On-Load/ Off-Load” Single Fall Release Gear System - Type: “ LHR9 M2 and LHR 9 M2 with Training Lock”

IMO Resolution MSC.81 (70) Part 1 as amended by resolution MSC 226 (82) and MSC 321 (89)

Expires: 10 December 2017

MED 1250254

Page 313: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

313 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Vanguard (Nantong) F.R.P Co. Ltd, Tongzhou City, Sanyu Town, Nantong, Jiangsu Province, 226331, China, People's Republic of.

Off-load Release Hook for single fall davit launched rescue boats - Type: “ Spear Head 15 KN ” .

RELEASE GEAR IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82) and MSC.321 (89).

Expires: 7 March 2021

MED 1650127

Wuxi City Xingsheng Gear Case Factory, Shi Tang Wan Town, Wuxi City, Jiangsu Province, 214185, China, People's Republic of.

Rescue Boat Manual On-load/ Off-load release hook type “ 15kN Rescue Boat Release Hook”

RELEASE GEAR IMO Resolution MSC.81 (70), Part 1 as amended MSC.226 (82) and MSC.321 (89).

Expires: 25 June 2020

MED 1550151/ M1

Wuxi Wenjiao GFRP Factory, Hong Xi cun, Hongsheng town, Wuxi City, Jiangsu, 214115, China, People's Republic of.

On/ Off-Load Single fall release gear system for rescue boat – Type: “ WJHK-40”

RELEASE M ECHANISM IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 226 (82) and MSC 321(89)

Expires: 30 June 2019

MED 1450150

Page 314: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26a RELEASE M ECHANISM FOR LIFEBOAT & RESCUE BOATS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

314 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Zhenjiang M arine Auxiliary M achinery Works, CSSC Nanjing Luzhou M achine Co., Ltd, 56 Yuehe Street, Jianbi, Zhenjiang, Jiangsu, 212006, China, People's Republic of.

Rescue Boat Manual Off-Load Release Mechanism Type “HK40”.

RELEASE M ECHANISM IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.226 (82), MSC.321 (89).

Expires: 11 September 2018

MED 1350117

Page 315: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.26b RELEASE M ECHANISM FOR LIFERAFTS LAUNCHED BY A FALL OR FALLS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

315 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Bianchi & Cecchi Service Europe SRL, Via Al M olo Giano, Genova, 16128, I taly.

3.5 tonne SWL automatic release hook for liferafts – Type: “ U-ARH 3,5”

RELEASE MECHANISM IMO Resolution MSC.81(70) Part 1 as amended

Expires: 24 October 2021

MED 1650259/ M1

Survitec Group, Kingsway, Dunmurry, Belfast, BT17 9AF, Northern Ireland.

3.5 tonne SWL automatic release mechanism for liferafts and rescue boats – Type: “ RFD M k 6”

RELEASE M ECHANISM IMO Resolution MSC.81(70) Part 1 Expires: 19 December 2020

MED 1650018

Umoe Schat-Harding BV, P.O. Box 337, 3990 GC Houten, Wilgenkade 17-19, 3992 LL Houten, Netherlands, The.

Automatic release mechanism for davit launched liferafts - Type: “ ARH 33”

RELEASE GEAR IMO Resolution MSC.81(70) Part 1 Expires: 1 January 2021

MED 1550275

Automatic release hook for davit launched liferafts – Type: “ ARH 23”

RELEASE M ECHANISM FOR LIFERAFTS

IMO Resolution MSC.81(70) Part 1 Expires: 1 January 2021

MED 1550276

Wuxi City Xingsheng Gear Case Factory, Shi Tang Wan Town, Wuxi City, Jiangsu Province, 214185, China, People's Republic of.

Liferaft Automatic single fall On-load/ Off-load release hook type “ 21/ 25kN and Liferaft Auto Release Hook XS21-2004”

RELEASE GEAR IMO Resolution MSC.81 (70) Part 1 as amended

Expires: 26 October 2019

MED 1450179/ M1

Automatic Release Hook for Davit Launched Liferafts and Rescue Boats Type: “ 35 KN”

RELEASE GEAR IMO Resolution MSC.81 (70), Part 1 as amended.

Expires: 25 June 2020

MED 1550152/ M1

Page 316: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.27 M ARINE EVACUATION SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

316 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Survitec Group, Kingsway, Dunmurry, Belfast, BT17 9AF, Northern Ireland.

Vertical chute gravity deployed marine evacuation system with direct access liferafts – Type: “ Marin Ark Mk II MES including Additional Primary Capacity arrangement”

M ARINE EVACUATION SYSTEM S (M ES)

IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.295 (87) and MSC.323 (89)

Expires: 23 March 2019

MED 1450065/ M1

Vertical chute gravity deployed Marine Evacuation System with liferafts – Type” MAS – 67 ”

M arine Evacuation Systems IMO Resolution MSC.81 (70)Part.1 as amended to date.

Expires: 16 June 2019

MED 1450124

Vertical chute gravity deployed marine evacuation system with direct access liferafts – Type: “ Marin Ark Single Liferaft MK II MES”

M ARINE EVACUATION SYSTEM S IMO Resolution MSC.81(70)Part.1 as amended to date

Expires: 6 October 2019

MED 1450242/ M1

Vertical chute gravity deployed marine evacuation system with the direct access liferafts – Type: “M ES II – M ARIN ARK M K1”.”

M ARINE EVACUATION SYSTEM S (M ES)

IMO Resolution MSC.81 (70) Part 1 Expires: 19 April 2020

MED 1550057

Survitec Group Limited, Beaufort Road, Birkenhead, M erseyside, CH41 1HQ, United Kingdom (UK).

Inclined gravity deployed inflatable Marine Evacuation system without a platform but with direct access liferafts – Type: “ M arin Ark 109 Slide M ES”

M ARINE EVACUATION SYSTEM S IMO Resolution MSC.81 (70) Part 1. ISO 15738 (2002).

Expires: 3 June 2018

MED 1350066 USCG Module B No: 160.175/ EC0038

Inclined gravity deployed inflatable Marine Evacuation system without a platform but with direct access liferafts – Type: “ M ARIN ARK M ES 109 DUAL POINT BOWSING, OFFSET ARRANGEM ENT”

M ARINE EVACUATION SYSTEM S IMO Resolution MSC.81(70), Part 1 as amended by MSC.226(82). ISO 15738 (2002)

Expires: 13 March 2022

MED 1750042

Page 317: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.27 M ARINE EVACUATION SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

317 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

VIKING Life-Saving Equipment Norge AS, Idrettsvegen 110, NO-5353 Straume, Norway.

Vertical chute gravity deployed marine evacuation system with liferafts – Type: “ Venoc Viking M ES” .

Marine Evacuation Systems (MES) IMO Resolution MSC.81(70), Part 1.

Expires: 19 April 2017

MED 1250067/ M1

Page 318: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.28 M EANS OF RESCUE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

318 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Survitec Group Ltd., Beaufort Road, Birkenhead, M erseyside, CH41 1HQ, United Kingdom (UK).

25 person davit launched means of rescue – Type: “ RFD M eans of Rescue” (also known as “ Survitec Zodiac M eans of Rescue” and “ DBC M eans of Rescue” )

M EANS OF RESCUE IMO MSC Circ. 810 O Resolution MSC.81(70), Part 1 as amended by MSC.226(82) and MSC.295(87) ISO 15738 (2002)

Expires: 5 December 2020

MED 1550282

Page 319: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.29 EM BARKATION LADDERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

319 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Captain Nemo, 7 Vasiladiou Street, 18540 Piraeus, Greece.

Embarkation Ladder. LADDERS IMO Res. MSC.81(70) ISO 5489 (2008)

Expires: 11 November 2018

MED 1350148

Jiangsu Yuyuan M arine Outfitting Co., Ltd., XingJiang East Road, The Civilian's Economic Developing Zone, Jiangyan Town, Taizhou City, Jiangsu Province, China, People's Republic of.

Ladders EM BARKATION LADDER IMO Resolution MSC.81(70) ISO 5489(2008)

Expires: 7 April 2020

MED 1550077

M arine Safety Supplies Ltd, Unit 2-3, M arine House, Willington Quay, Wallsend, Tyne & Wear, NE28 6SU, United Kingdom (UK).

Embarkation Ladder LADDER IMO Res. MSC.81(70) ISO 5489 (2008)

Expires: 16 June 2019

MED 1450128

M itani Shoten Co. Ltd, 8-19, 1-chome, Kizugawa, Naniwa-ku, Osaka, 556-0027, Japan.

Embarkation Ladder Type “ ELM2” LADDERS IMO Res. MSC.81 (70), Part 1 as amended. ISO 5489 (2008)

Expires: 13 September 2020

MED 1550163

Sea contractor (S) Pte Ltd, 40, Gul Crescent, 629540, Singapore.

SCS Seamaster Embarkation Ladder Flat. Type ” EFM 60 meter”

EM BARKATION LADDER IMO Resolution MSC.81 (70), Part 1 as amended. ISO 5489 (2008)

Expires: 12 July 2020

MED 1550164/ M1

Page 320: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.29 EM BARKATION LADDERS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

320 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Seny Ltd, 7 Alexander Dyakovich Str, 9000Varna, Bulgaria.

Embarkation Ladder Embarkation Ladder IMO Res. MSC.81(70) ISO 5489 (2008)

Expires: 30 March 2021

MED 1650110

Page 321: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.2a POSITION-INDICATING LIGHTS FOR LIFE-SAVING APPLIANCES - FOR SURVIVAL CRAFT & RESCUE BOAT

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

321 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Daniamant Limited, Unit 3,The Admiral Park, Airport Service Road, Hilsea, Portsmouth, Hampshire, PO3 5RQ, United Kingdom (UK).

Manually controlled flashing position indicating lights for survival craft – Type “Rescue-M aster 1, Rescue-M aster Lite GB”

LIFERAFT LIGHTS IMO Resolution MSC.81(70), Part 1, as amended by Resolution MSC.226(82), MSC.200(80) & MSC. 323(89)

Expires: 21 November 2021

MED 1650281

Manually controlled flashing position indicating lights for survival craft – Type: “Rescue-M aster 2B, Rescue-M aster 3B and Rescue-M aster 12V“

Liferaft Lights IMO Resolution MSC.81(70), Part 1, as amended by Resolution MSC.226(82), MSC.200(80) and MSC.323(89)

Expires: 21 November 2021

MED 1650282

LIFERAFT LIGHTS Annex A.1/ 1.2 Position-indicating lights for life saving appliances: (a) For survival craft and rescue boats Manually controlled flashing position indicating lights for survival craft – Type “ RL5 (Daniamant)”

IMO Resolution MSC.81(70), Part 1, as amended

Expires: 23 March 2022

MED 1750055

LIFERAFT LIGHTS Manually controlled flashing position indicating lights for survival craft – Type “ RL5 Viking”

IMO Resolution MSC.81(70), Part 1, as amended

Expires: 26 March 2022

MED 1750058

LIFERAFT LIGHTS Manually controlled flashing position indicating lights for survival craft – Type “ RL5 (RFD), RL5 ( DSB) and RL5 (EV)”

IMO Resolution MSC.81(70), Part 1, as amended

Expires: 26 March 2022

MED 1750059

Page 322: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.2b POSITION-INDICATING LIGHTS FOR LIFE-SAVING APPLIANCES - FOR LIFEBUOYS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

322 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Chemring Defence UK Ltd, Wilne M ill, Draycott, Derby, DE72 3QJ, United Kingdom (UK).

Position indicating light for lifebuoys Type – “M OB Y400”

Position Indicating Light for Lifebuoys

IMO Res.MSC.81 (70) Part 1 as amended by MSC.200 (80), MSC.226 (82) & MSC.323 (89)

Expires: 1 July 2019

MED 1450152

E G Vallianatos S A (EVAL), Location Tzaverthella, 13310 Ano Liosia, Athens, Greece.

Lifebuoy self-igniting light for use with both throw-over and quick release lifebuoys-Type:"2961"

LIFEBUOY LIGHTS IMO Resolution MSC.81(70), Part 1 as amended by MSC.218(82) and MSC.323(89)

Expires: 25 July 2019

MED 1450238

Page 323: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.2c POSITION-INDICATING LIGHTS FOR LIFE-SAVING APPLIANCES - FOR LIFEJACKETS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

323 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Daniamant ApS, Industrivej 24C, DK-3550 Slangerup, Denmark.

l ifejacket flashing light – water activated - Type: “ Rescue Dan WR”

Lifejacket Lights IMO Resolution MSC.81(70) Part 1 amended by resolution MSC.226(82) and MSC 200(80) ISO 24408 (2005)

Expires: 7 April 2015

MED 1050079

l ifejacket flashing light - manually operated - Type: “ Rescue Dan MR”

Lifejacket Lights IMO Resolution MSC.81(70) Part 1 amended by resolution MSC.226(82) and MSC 200(80) ISO 24408 (2005)

Expires: 7 April 2015

MED 1050080

Daniamant Limited, Unit 3,The Admiral Park, Airport Service Road, Hilsea, Portsmouth, Hampshire, PO3 5RQ, United Kingdom (UK).

Lifejacket water activated flashing light – Type: “ Daniamant L7A”

Lifejacket Lights IMO Resolution MSC.81(70) Part 1 amended by resolution MSC.226(82) and MSC 200(80) ISO 24408 (2005)

Expires: 11 October 2015

MED 1050221

Flashing Lifejacket Light – Type: “ L6-Ex and L6 A-Ex”

Lifejacket Lights IMO Resolution MSC 81(70) Part 1 as amended by resolution MSC.226 (82), MSC 200(80) and MSC.323(89).

Expires: 2 November 2021

MED 1650264

Position Indicating flashing light for lifejackets – Type “ L7-A2”

LIFEJACKET LIGHTS IMO Resolution MSC.81(70), Part 1, as amended by Resolution MSC.200(80), MSC.226(82) and MSC.323(89)

Expires: 20 November 2021

MED 1650280

Page 324: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.2c POSITION-INDICATING LIGHTS FOR LIFE-SAVING APPLIANCES - FOR LIFEJACKETS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

324 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Precimold Inc., 9 M arie - Victorin Boulevard, Candiac (M ontreal), Quebec J5R 4S8, Canada.

Self-contained water activated flashing LED light for attachment to lifejackets. Type: “ Smartlite EJE-01034-XX”

Lifejacket Lights IMO Resolution MSC.81(70) Part 1 amended by resolution MSC.226(82) and MSC 200(80)

Expires: 16 February 2016

MED 1150073

Page 325: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.3 LIFE-BUOYS SELF-ACTIVATING SM OKE SIGNALS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

325 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Chemring Defence UK Ltd, Wilne M ill, Draycott, Derby, DE72 3QJ, United Kingdom (UK).

Lifebuoy self-igniting light and self-activating smoke signal - Type: “ MOB Y400”

LIFEBUOY SELF ACTIVATING SM OKE SIGNAL

IMO Res. MSC.81 (70) Part 1 as amended by MSC.200 (80), MSC.226 (82) & MSC.323 (89)

Expires: 1 July 2019

MED 1450151

Page 326: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.30 RETRO-REFLECTIVE M ATERIALS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

326 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

3M Personal Safety Division, 3M Center, Bldg 235-2F-06, St. Paul, M N 55144-1000, United States of America (USA).

Retro-reflective marking material – Type: “ ScotchliteTM High Intensity Grade SOLAS Reflective Sheeting Series 3150-A” .

RETRO-REFLECTIVE M ATERIALS IMO Resolution A.658 (16), Annex 2.

Expires: 7 August 2018

MED 1350104

Retro-reflective marking material – Type: “ ScotchliteTM High Intensity Grade SOLAS Reflective Sheeting Series 6750-I” .

RETRO-REFLECTIVE M ATERIAL

IMO Resolution A.658 (16) Annex 2.

Expires: 7 August 2018

MED 1350105

Retro-reflective material. For attachment by stitching/ sewing – Type: “ ScotchliteTM SOLAS Grade 6755” .

RETRO-REFLECTIVE M ATERIAL IMO Resolution A.658 (16), Annex 2.

Expires: 7 August 2018

MED 1350106

Daoming Optics & Chemicals Co.,Ltd, No. 001 Yingbin Road, 3rd Xiangzhu Industrial Zone,, Yongkang, Zhejiang Province, 321313, China, People's Republic of.

Retro-Reflective Sheeting – Type – Class I “ DM1101A”

Retro-Reflective M aterials IMO Resolution A. 658(16) Expires: 3 November 2020

MED 1550248/ M1

Page 327: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.30 RETRO-REFLECTIVE M ATERIALS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

327 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Hefei Xingtu Reflective M aterial Co., Ltd, Longtong Industrial Park, Cuozhen Town, Feigong County, Hefei City, Anhui Province, 231602, China, People's Republic of.

Retro-reflective sheeting – Type - Class I “XT 1800 M arine Grade SOLAS”

RETRO-REFLECTIVE M ATERIALS IMO Resolution A.658 (16), Annex 2

Expires: 20 September 2020

MED 1550223

Lalizas Hellas, 3 Gounari Street, 185 31 Piraeus, Greece.

Retro-Reflective Tape – Class II “ LA70180”

Retro-Reflective Materials IMO Resolution A. 658(16) Expires: 10 October 2021

MED 1650253

Page 328: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.36 LIFEBOAT/RESCUE BOAT PROPULSION ENGINE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

328 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Changzhou Bosin M echanical Co. Ltd, Weicun, Xinbei district of Changzhou City, 213127, China, People's Republic of.

19.8 KW, 3 Cylinder, Water Cooled Inboard Diesel Engine for Life/ Rescue Boats - Type: “ BS380J “ .

LIFEBOAT/RESCUE BOAT PROPULSION ENGINE “

IMO Resolution MSC.81(70), Part 1 as amended to date.

Expires: 23 June 2019

MED 1450164

HLB CO., Ltd., 272-12, Dangwol-ro, Onsan-Eup, Ulju-Gun, Ulsan, 689-892, Korea, Republic of.

37.3 kW, (50 HP) 4 stroke, x 4 cylinder, water cooled inboard diesel engine for life/ rescue boats - Type: “ HB50D1”

LIFEBOAT/ RESCUE BOAT PROPULSION ENGINE

IMO Resolution MSC.81 (70), Part 1 as amended to date

Expires: 16 January 2018

MED 1350004

17.15kW, (23 HP) 4 stroke, x 3 cylinder, water cooled inboard diesel engine for life/ rescue boats – Type: “ HB23D1”

LIFEBOAT/RESCUE BOAT PROPULSION ENGINE

IMO Resolution MSC.81(70), Part 1

Expires: 8 October 2018

MED 1350128

21.6 kW, (29 HP) 4 stroke, x3 cylinder, water cooled inboard diesel engine for life/ rescue boats - Type: “ HB29D1“

A.1/1.36 LIFEBOAT/RESCUE BOAT PROPULSION ENGINE

IMO Resolution MSC.81(70), Part 1 as amended to date.

Expires: 16 May 2020

MED 1550187

35 persons free-fall launched, totally enclosed, GRP Lifeboat, with self-contained air support system and water spray fire protection system - Type: “HDFN35F” (Tanker Version)

LIFEBOATS IMO Resolution MSC.81(70) Part 1, as amended. IMO MSC Circular 1006

Expires: 16 May 2020

MED 1550188

Page 329: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.37 RESCUE BOAT PROPULSION ENGINE-OUTBOARD M OTOR

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

329 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

YAM AHA M OTOR EUROPE N.V, Koolhovenlaan 101, 1119NC Schiphol-Rijk, Netherlands, The.

97.0kW (130HP), 2 stroke, 4 cylinder petrol outboard engine for rescue boats - Types: “ Yamaha 130B” and “ Yamaha L130B”

Rescue Boat Propulsion Engine-Outboard Engine

IMO Resolution MSC.81(70) Part 1.

Expires: 24 March 2015

MED 1050071

85.8kW (115HP), 2 stroke, 4 cylinder petrol outboard engine for rescue boats - Types: “ Yamaha 115B” and “ Yamaha 115C”

Rescue Boat Propulsion Engine-Outboard Motor

IMO Resolution MSC.81(70) Part 1.

Expires: 24 March 2015

MED 1050072

18.4kW (25HP), 2 stroke, 2 cylinder petrol outboard engine for rescue boats - Type: “ Yamaha 25N”

Rescue Boat propulsion Engine-Outboard Motor

IMO Resolution MSC.81(70) Part 1.

Expires: 23 April 2020

MED 1550095

51.5kW (70HP), 2 stroke, 3 cylinder petrol outboard engine for rescue boats - Type: “ Yamaha 70B”

Rescue Boat Propulsion Engine-Outboard Engine

IMO Resolution MSC.81(70) Part 1.

Expires: 23 April 2020

MED 1550096

55.2kW (75HP), 2 stroke, 3 cylinder petrol outboard engine for rescue boats - Type: “ Yamaha 75C”

Rescue Boat Propulsion Engine-Outboard Motor

IMO Resolution MSC.81(70) Part 1.

Expires: 23 April 2020

MED 1550097

66.2kW (90HP), 2 stroke, 3 cylinder petrol outboard engine for rescue boats - Type: “ Yamaha 90A”

Rescue Boat Propulsion Engine-Outboard Motor

IMO Resolution MSC.81(70) Part 1.

Expires: 23 April 2020

MED 1550098/ M1

Page 330: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.39 OPEN REVERSIBLE LIFE-RAFTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

330 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Survitec Group, Kingsway, Dunmurry, Belfast, BT17 9AF, Northern Ireland.

30 persons capacity throw/ roll over open reversible liferaft – Type: “ RFD Ferryman 30” (also known as “ Beaufort 30, DSB LR14R, Crewsaver, Elliot, Survitec, Survitec Zodiac, SSPI, RFD Toyo” ).

INFLATABLE LIFERAFTS IMO Res. MSC.36 (63) – (1994 HSC Code) Annex 10 IMO Res. MSC.97 (73) – (2000 HSC Code) Annex 11 ISO 15738:2002

Expires: 28 April 2020

MED 1550103

25 person capacity throw/ roll over open reversible liferaft – Type: “ RFD Ferryman 25” and “ Beaufort 25 ORL”

Inflatable Liferafts

IMO Res. MSC.36(63)-(1994 HSC Code) Annex 10

O Res. MSC.97(73)-(2000 HSC Code) Annex 11 ISO 15738:2002

Expires: 16 May 2020

MED 1550113

50 person capacity throw/ roll over open reversible liferaft - Type: “ RFD Ferryman 50” , “ Beaufort 50 ORL” , “ DSB LR14R” , “ Crewsaver” , “ Elliot” , “ Survitec Zodiac” , “ SSPI” , “ RFD Toyo” & “ Survitec” .

Inflatable Liferafts

IMO Res. MSC.36(63)-(1994 HSC Code) Annex 10, IMO Res. MSC.97(73)-(2000 HSC Code) Annex 11.

Expires: 16 May 2020

MED 1550114

100 person capacity throw/ roll over open reversible liferaft – Type: “ RFD Ferryman 100” , “ Beaufort 100 ORL” , “ DSB LR14R” , “ Crewsaver” , “ Elliot” , “ Survitec Zodiac” , “ SSPI” , “ RFD Toyo” & “ Survitec” .

INFLATABLE LIFERAFTS IMO Res. MSC.36(63)-(1994 HSC Code) Annex 10 IMO Res. MSC.97(73)-(2000 HSC Code) Annex 11

Expires: 16 May 2020

MED 1550115

Page 331: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.4 LIFEJACKETS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

331 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lalizas Hellas, 3 Gounari Street, 185 31 Piraeus, Greece.

Inherently buoyant Adult Folding Lifejacket - Type: “ 70179 Advanced Folding Lifejacket SOLAS-(LSA Code) 2010”

Lifejackets IMO Resolution MSC.81 (70) Part 1, as amended by IMO Resolution MSC.200 (80), MSC.226 (82), MSC.323 (89) & MSC.378(93)

Expires: 26 May 2020

MED 1550131/ M1

Inherently buoyant Adult Lifejacket - Type: “ 70178 Advanced Adult’s Lifejacket SOLAS-(LSA Code) 2010”

Lifejackets IMO Resolution MSC.81(70) Part 1, as amended by IMO Resolution MSC.200(80).

Expires: 13 January 2015

MED 1050016

Inherently buoyant Infant Lifejacket - Type: “ 70176 Advanced Infant Lifejacket SOLAS-(LSA Code) 2010”

Lifejackets

IMO Resolution MSC.81(70) Part 1, as amended by IMO Resolution MSC.200(80).

Expires: 13 January 2015

MED 1050017

Inherently buoyant Child Lifejacket - Type: “ 70177 Advanced Child Lifejacket SOLAS-(LSA Code) 2010”

Lifejacket IMO Resolution MSC.81 (70) Part 1, as amended by IMO Resolution MSC.200 (80), MSC.226 (82), MSC.323 (89) & MSC.378(93)

Expires: 26 May 2020

MED 1550141/ M1

Inherently buoyant Child Lifejacket - Type: “ 72215- LALIZAS Compact Child Folding Lifejacket SOLAS LSA Code 2016”

LIFEJACKETS IMO Resolution MSC.81 (70) Part 1, as amended by IMO Resolution MSC.200 (80), MSC.226 (82), MSC.323 (89) & MSC.378 (93)

Expires: 28 June 2021

MED 1650168

Inherently buoyant Adult Lifejacket - Type: “ 72214- LALIZAS Compact Folding Lifejacket SOLAS LSA Code 2016”

LIFEJACKETS IMO Resolution MSC.81 (70) Part 1, as amended by IMO Resolution MSC.200 (80), MSC.226 (82), MSC.323 (89) & MSC.378 (93)

Expires: 28 June 2021

MED 1650169

M ustang Survival ULC, 7525 Lowland Drive, Burnaby, BC, V5J 5L1, Canada.

LIFEJACKETS Inherently buoyant Adult Lifejacket - Type: “ MV8040”

IMO Resolution MSC.81 (70) Part 1, as amended by IMO Resolution MSC.200 (80), MSC.207 (81), MSC.226 (82) and MSC.323 (89).

Expires: 25 March 2018

MED 1350034/ M1

Page 332: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.4 LIFEJACKETS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

332 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

LIFEJACKETS Inherently buoyant Child Lifejacket - Type: “ MV8035”

IMO Resolution MSC.81 (70) Part 1, as amended by IMO Resolution MSC.200 (80), MSC.207 (81), MSC.226 (82) and MSC.323 (89).

Expires: 25 March 2018

MED 1350035/ M1

Ocean Safety Limited, Saxon Wharf, Lower York Street, Southampton, SO14 5QF, United Kingdom (UK).

Twin chamber inflatable lifejacket for adults - Type: “Falcon 275N”

LIFEJACKETS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.200 (80), MSC.207 (81), MSC.226 (82) & MSC.323 (89).

Expires: 15 September 2015

MED 1050253/ M3

Page 333: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.4 LIFEJACKETS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

333 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Ocean Safety Limited ...continued

Twin chamber inflatable lifejacket for adults - Type: ” K² Twin”

LIFEJACKETS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.200 (80), MSC.226 (82) and MSC.323 (89)

Expires: 25 July 2016

MED 1150198/ M2

Regatta AS, Borgundfjordveien 80, Alesund, N-6017, Norway.

Inherently Buoyant Adult Lifejacket – Type: “ KON-TIKI ROYAL”

LIFEJACKETS IMO Resolution MSC.81 (70), Part 1, MSC.200 (80), MSC.207 (81), MSC.226 (82) & MSC.323 (89)

Expires: 4 March 2019

MED 1450142

Inherently Buoyant Child Lifejacket – Type: “ KON-TIKI ROYAL”

LIFEJACKETS IMO Resolution MSC.81 (70), Part 1, MSC.200 (80), MSC.207 (81), MSC.226 (82) & MSC.323 (89).

Expires: 4 March 2019

MED 1450143

Survitec Services & Distribution Ltd. trading as Crewsaver, Crewsaver, M umby Road, Gosport, Hampshire, PO12 1AQ, United Kingdom (UK).

Twin chamber inflatable Lifejacket for adults – Type: “Seacrewsader 2010” and “Crewfit Twin 2010”.

LIFEJACKETS IMO Resolution MSC.81 (70), Part 1 as amended by Resolution MSC.200 (80), MSC.207 (81), MSC.226 (82) and MSC.323 (89).

Expires: 9 August 2020

MED 1550205

Survitec Services & Distribution Trading as Crewsaver, Survitec House, Lederle Lane, Gosport, PO13 0FZ, United Kingdom (UK).

Lifejackets Type “ 150N Seacrewsader 2010 & 150N Crewfit Twin 2010 tw in chambered Lifejackets” .

LIFEJACKETS IMO Resolution MSC.81 (70) Part 1, as amended by Resolution MSC.200 (80), MSC.207 (81), MSC.226 (82) and MSC.323 (89).

Expires: 12 February 2018

MED 1350016

Inherently Buoyant Adult Lifejacket – Type: “ Premier 2010” also known as “ M ERM AN 20” .

LIFEJACKETS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.200 (80), MSC.207 (81) and MSC.226 (82).

Expires: 31 July 2018

MED 1350100

Page 334: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.4 LIFEJACKETS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

334 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Inherently Buoyant Child Lifejacket – Type: “ Premier 2010” also known as “ M ERM AN 20”

LIFEJACKETS IMO Resolution MSC.81 (70), Part 1 as amended by Resolution MSC 200 (80), MSC. 207 (81) and MSC.226 (82).

Expires: 31 July 2018

MED 1350101

Inherently Buoyant Infant Lifejacket – Type: “ Premier 2010” also known as “ M ERM AN 20”

LIFEJACKETS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.200 (80), MSC. 207 (81) and MSC.226 (82).

Expires: 31 July 2018

MED 1350102

Inherently Buoyant Adult Lifejacket – Type “ 1199 Premier Compact” .

LIFEJACKETS IMO Resolution MSC.81 (70), Part 1 as amended by Resolution MSC.200 (80), MSC.207 (81), MSC.218 (82), MSC.323 (89) and MSC.378 (93).

Expires: 17 June 2020

MED 1550147

Page 335: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.4 LIFEJACKETS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

335 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

TakashinaLifePreserversCoLtd, 1-1-30KuboyoshiNaniwaKu, Osaka, 556-0028, Japan.

Inherently Buoyant Child Lifejacket – Type: ” TK-006C “

Lifejackets IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 200(80) and MSC 226(82).

Expires: 8 June 2016

MED 1150164/ M1

Inherently Buoyant Infant Lifejacket – Type: “ TK-006I”

Lifejackets IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 200(80) and MSC 226(82).

Expires: 8 June 2016

MED 1150165/ M1

Inherently Buoyant Adult Lifejacket – Type: “ TK-006A”

Lifejackets IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 200(80) and MSC 226(82).

Expires: 25 July 2016

MED 1150199/ M1

The Coleman Company, Inc., 3600 N Hydraulic, Wichita, KS 67226, United States of America (USA).

Inherently Buoyant Infant Lifejacket – Type: “ I140”

LIFEJACKETS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.200 (80), MSC.226 (82) and MSC.323 (89).

Expires: 10 January 2016

MED 1150006/ M2

Inherently Buoyant Child Lifejacket – Type: – Type: ” I150 “

LIFEJACKETS IMO Resolution MSC.81 (70) Part 1 as amended by Resolution MSC.200 (80), MSC.226 (82) and MSC.323 (89).

Expires: 10 January 2016

MED 1150007/ M2

Inherently Buoyant Adult Lifejacket – Type: ” I160 “

Lifejackets IMO Resolution MSC.81(70) Part 1 as amended by resolution MSC 200(80) and MSC 226(82).

Expires: 10 January 2016

MED 1150008/ M1

Page 336: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.41 WINCHES FOR SURVIVAL CRAFT & RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

336 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

CSSC Nanjing Luzhou M achine Co., Ltd, Zhenjiang M arine Auxiliary M achinery Works, #56 Yuehe Street, Jianbi Town, Zhenjiang City, Jiangsu Province, 212006, China, People's Republic of.

Hydraulic powered w inch - Type: “ HDCL2-6.5”

Winches For Survival Craft And Rescue Boats

IMO Resolution MSC.81(70) Part 1 Expires: 6 December 2016

MED 1150320

d-i davit international gmbh, Sandstrasse 20, 27232 Sulingen, Germany.

Winches For Survival Craft & Rescue Boats

Electric Rescue Boat Winch – Type: 06.24

IMO Resolution MSC.81(70), Part 1.

Expires: 31 January 2015

MED 1050029

Fast Rescue Boat Hydraulic Winch – Type: “ 07.20.01”

Launching Appliances IMO Resolution MSC.81(70), Part 1

Expires: 17 March 2016

MED 1150089

Harding Safety AS, Seimsvegen 116, 5472 Seimsfoss, Norway.

Double barrel lifeboat w inch powered by an electric / hydraulic motor - Type: “ W 150 H, W 150 L, W150 OLLD, W150 TLD, W150 TH LD, W150 LLD, W150 LM LD, WH 150 TLD, WH150 OL, W150 LS, W150 LLDS”

WINCHES FOR SURVIVAL CRAFTS IMO Resolution MSC.81 (70), Part 1 as amended

Expires: 23 June 2019

MED 1450144

Harding Safety AS, 5472 Seimsfoss, Norway.

Electro-hydraulic lifeboat and/ or rescue boat w inch – Type: “ W80 range”

WINCHES FOR SURVIVAL CRAFT/RESCUE BOATS

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 18 May 2020

MED 1550118

Page 337: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.41 WINCHES FOR SURVIVAL CRAFT & RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

337 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Harding Safety Netherlands B.V., Wilgenkade 17-19, 3992 LL Houten, Netherlands, The.

Electric Boat Winch Type: “ 16-EBR” . WINCHES FOR SURVIVAL CRAFT AND RESCUE BOATS

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 26 January 2020

MED 1550021

Jiangyin Neptune M arine Appliance Co. Ltd, 25# North Road, Yuecheng Town, Jiangyin City, Jiangsu Province, China, People's Republic of.

Electric Lifeboat Winch – Type: “ NPT/ DW138 S”

Winches For Survival Craft And Rescue Boats

IMO Resolution MSC.81(70), Part 1 as amended to date.

Expires: 17 August 2015

MED 1050240

Electric Lifeboat/ Rescue Boat Winch – Type: “ NPT50DW”

Winches for Survival Craft/ Rescue Boats

IMO Resolution MSC.81(70), Part 1 as amended by Resolution MSC.226(82) and MSC.274(85)

Expires: 31 January 2016

MED 1150050/ M1

Page 338: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.41 WINCHES FOR SURVIVAL CRAFT & RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

338 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jiangyin Neptune M arine Appliance Co. Ltd ...continued

Electric Lifeboat/ Rescue Boat Winch – Type: “ NPT/ DW 100 S/ Z”

WINCHES FOR SURVIVAL CRAFT/RESCUE BOATS

IMO Resolution MSC.81 (70), Part 1

Expires: 9 December 2019

MED 1550232

Jiangyin Wolong F.R.P Boat Co. Ltd, Yuecheng Town, Jiangyin City, Jiangsu, 214404, China, People's Republic of.

35 KN Hydraulic Lifeboat Winch – Type: “ FH-70HW ”

Winches for Survival Craft/ Rescue Boats

IMO Resolution MSC.81(70), Part 1.

Expires: 27 July 2016

MED 1150200

Electric Lifeboat/ Rescue Boat Winch – Type: “ JY-D50S/ Z”

Winches For Survival Craft/ Rescue Boats

IMO Resolution MSC.81(70), Part 1 as amended.

Expires: 20 March 2017

MED 1250047

45 KN Hydraulic Lifeboat Winch – Type: “ JY–FH90”

WINCHES FOR SURVIVAL CRAFT & RESCUE BOATS (b) free-fall l ifeboats

IMO Resolution MSC.81(70), Part 1

Expires: 23 September 2021

MED 1750033/ M1

Jiangyinshi Beihai LSA Co., Ltd., 33# Beihuan Road, Yuecheng Town, Jiangyin City, Jiangsu Province, 214404, China, People's Republic of.

45kN Electric Boat Winch Type: “JYBW45L/R”

WINCHES FOR SURVIVAL CRAFT & RESCUE BOAT

IMO Resolution MSC.81 (70) Part 1 as amended

Expires: 18 September 2018

MED 1350122

M ontmontaza-Greben d.o.o., 20270 Vela Luka, Obala 4, br.50, Croatia.

Electro-Htdraulic Rscue Boat Winch – Types: “ EW-2C”

Winches For Survival Craft

IMO Resolution MSC.81(70), Part 1 Expires: 8 May 2015

MED 1050245

Page 339: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.41 WINCHES FOR SURVIVAL CRAFT & RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

339 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Single Barrel Manual / Electric Rescue Boat Winch - Type: “ EW-2QC”

Winches For Survival Craft/ Rescue Boats

IMO Resolution MSC.81(70), Part 1

Expires: 8 May 2015

MED 1050251

Palfinger M arine Netherlands BV, Ambachtsweg 10, 3771 M G Barneveld, Barneveld, Netherlands, The.

Winch Type – WP65 WINCHES FOR SURVIVAL CRAFT (LIFEBOAT)

IMO Resolution MSC.81 (70) Part 1 as amended

Expires: 20 February 2019

MED 1450039/ M2

Rescue Boat Winch – Type: “ Winch 15-01R” .

WINCHES FOR SURVIVAL CRAFT (RESCUE BOAT)

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 12 June 2019

MED 1450130/ M1

Rescue Boat Winch - Type “ 04-04 H/ HS” .

WINCHES FOR RESCUE BOATS IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 18 August 2019

MED 1450175/ M2

Page 340: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.41 WINCHES FOR SURVIVAL CRAFT & RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

340 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Palfinger M arine Netherlands BV ...continued

Rescue Boat Winch – Type: “ 04-04 – HH HS” .

WINCHES FOR SURVIVAL CRAFT (RESCUE BOAT)

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 21 April 2020

MED 1550088/ M1

Rescue Boat Winch – Type: “ 04-04 – HH ES” .

WINCHES FOR SURVIVAL CRAFT (RESCUE BOAT)

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 22 April 2020

MED 1550089/ M1

Manual Liferaft Winch – Type: “ 04-04 – HH MS” .

WINCHES FOR LIFERAFT IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 22 April 2020

MED 1550100/ M1

Single Barrel Electric Rescue Boat Winch – Type: “ WL-2”

WINCHES FOR RESCUE BOATS IMO Resolution MSC.81 (70), as amended.

Expires: 11 December 2020

MED 1550241

Rescue Boat Winch – Type: “ 04-04 E/ ES”

WINCHES FOR SURVIVAL CRAFT (RESCUE BOAT)

IMO Resolution MSC.81 (70) Part 1 as amended

Expires: 19 November 2020

MED 1550260/ M3

Manually Operated Liferaft Winch – Type: “Winch 04-04 M /M S”

WINCHES FOR SURVIVAL CRAFT/RESCUE BOATS

IMO Resolution MSC.81 (70) Part 1 as amended

Expires: 21 March 2021

MED 1650098/ M2

Palfinger M arine Safety AS, Seimsvegen 116, 5471 Seimsfoss, Norway.

Single drum life/ rescue boat w inch powered by an electric motor – Type: “FM E 3.3” range

Winches for Survival Craft and Rescue Boat

IMO Resolution MSC.81(70), Part 1

Expires: 19 February 2022

MED 1750017

Electro-hydraulic life/ rescue boat winch – Type: “W50-range”

Winches for Survival Craft and Rescue Boat

IMO Resolution MSC.81(70), Part 1

Expires: 19 February 2022

MED 1750018/ M1

TECNIM PIANTI S.p.A., Str. Cons. Fiume Torto, 90018 Termini Imerese (PA), I taly.

Electric Rescue Boat Winch - Type: “DGE HW6R”

WINCHES FOR SURVIVAL CRAFT/RESCUE BOATS

IMO Resolution MSC.81(70), Part 1

Expires: 20 February 2022

MED 1750019

Electric Liferaft Winch - Type: “DGE HW35LR”

WINCHES FOR SURVIVAL CRAFT IMO Resolution MSC.81(70), Part 1 Expires: 20 February 2022 MED 1750020

Page 341: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.41 WINCHES FOR SURVIVAL CRAFT & RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

341 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Umoe Schat-Harding BV, P.O. Box 337, 3990 GC Houten, Wilgenkade 17-19, 3992 LL Houten, Netherlands, The.

Single drum, gravity lowering, manual hoisting liferaft winch – Type: “ 08-02 V” and “ 08-02 H”

Winches for Survival Craft/ Rescue Boats

IMO Resolution MSC.81(70) as amended by MSC 274(85)

Expires: 24 October 2015

MED 1050296

Single drum, gravity lowering, electric hoisting , rescue boat winch– Type: “ 08-34”

Winches for Survival Craft/ Rescue Boats

IMO Resolution MSC.81(70) as amended by MSC 274(85)

Expires: 31 October 2015

MED 1050304

Single Barrel Electric winch for Liferaft and Rescue Boat. Type: “ 1-13-17” .

WINCHES FOR SURVIVAL CRAFT/RESCUE BOATS

IMO Resolution MSC.81 (70), Part 1.

Expires: 7 August 2018

MED 1350103

Page 342: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.41 WINCHES FOR SURVIVAL CRAFT & RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

342 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Umoe Schat-Harding Equipment AS., N-5470 Rosendal, Norway.

Hydraulic lifeboat w inch – Type: “ WH 02 Range”

Winches for Survival Craft/ Rescue Boats

IMO Resolution MSC.81 (70) Part 1

Expires: 19 January 2016

MED 1150034

Electro-Hydraulic Lifeboat/ Rescue Boat Winch – Type: “ W120 Range”

WINCHES FOR SURVIVAL CRAFT/ RESCUE BOATS

IMO Resolution MSC.81 (70) Part 1

Expires: 11 April 2021

MED 1650118

Twin Drum Hydraulic Lifeboat Winch – Type: “WH160H & WH160H22”

Winches for Survival Craft and Rescue Boat

e-fall lifeboats

IMO Resolution MSC.81(70), Part 1. Expires: 11 January 2020

MED 1750050

Verhoef Aluminium Scheepsbouw Industrie BV, M olenweg 125, 1436 BS Aalsmeerderbrug, Netherlands, The.

Winches For Free-fall Lifeboats – Type: ” C11-457”

WINCHES FOR SURVIVAL CRAFT AND RESCUE BOATS

IMO Resolution MSC.81 (70), Part 1 as amended.

Expires: 4 June 2020

MED 1550139

Welin Lambie Ltd, Britannia House, Old Bush Street, Brierley Hill, West M idlands, DY5 1UB, United Kingdom (UK).

Rescue Boat Winch – Type: “ RBWPIV1A

Winches for Survival Craft/ Rescue Boats

IMO Resolution MSC.81(70) , Part 1 as amended by Resolution MSC.226(82) and MSC.274(85)

Expires: 10 April 2016

MED 1150108

Single Barrel Manual Liferaft Winch – Type “ LRW21A” .

WINCHES FOR LIFERAFT IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 4 September 2019

MED 1450181

Page 343: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.41 WINCHES FOR SURVIVAL CRAFT & RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

343 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wuxi Haidelong M arine Equipment Works, No. 63 Huanzhen West Road, Xida Bridge, Donghutang Town, Wuxi City, Jiangsu Province, 214196, China, People's Republic of.

WINCHES FOR SURVIVAL CRAFT Free fall l ifeboat (secondary means of launching) Electric Winch – Type: “ HDL70FA”

IMO Resolution MSC.81 (70), Part 1 as amended

Expires: 8 November 2017

MED 1250231

Electric Boat w inch - Type: “ HDLW21-00JS”

WINCHES FOR SURVIVAL CRAFT/RESCUE BOATS

IMO Resolution MSC.81 (70) Part 1 as amended.

Expires: 8 November 2017

MED 1250233

Wuxi Huahai M arine Equipment Factory, Jiangsu, Wuxi, Donggang Town 214196, China, People's Republic of.

Free-fall lifeboat (secondary means of launching), Winch Type – HM D55F.

WINCHES FOR SURVIVAL CRAFT IMO Resolution MSC.81 (70), Part 1 as amended.

Expires: 18 February 2019

MED 1450037

Page 344: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.41 WINCHES FOR SURVIVAL CRAFT & RESCUE BOATS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

344 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Zhenjiang Just M arine Equip. Co., Ltd., 21# Nanwei Second Road, DingM ao Developing Zone, Zhenjiang, Jiangsu, China, People's Republic of.

Survival Craft and rescue boat Electric Winch – Type: “ E63S/ Z”

Winches for Survival Craft/ Rescue Boats

IMO Resolution MSC.81(70) , Part 1 as amended by Resolution MSC.226(82) and MSC.274(85)

Expires: 10 April 2016

MED 1150109

Zhenjiang M arine Auxiliary M achinery Works, CSSC Nanjing Luzhou M achine Co., Ltd, 56 Yuehe Street, Jianbi, Zhenjiang, Jiangsu, 212006, China, People's Republic of.

Electric Driven Winch – Type: HDCL4-5

Winches For Survival Craft & Rescue Boats

IMO Resolution MSC.81(70), Part 1.

Expires: 2 June 2015

MED 1050127

Free Fall Lifeboat Hydraulic w inch ( secondary means of launching ) – Type: “ NINGBO IYJ3-21-7014-ZP”

Winches For Survival Craft & Rescue Boats

IMO Resolution MSC.81(70), Part 1.

Expires: 2 June 2015

MED 1050128

Page 345: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.43 Rigid/Inflated Recue Boats

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

345 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

NarwhalBoatsSL, CaminoSerraaAuga, M osPontevedra, Spain.

6 persons single fall davit launched rigid/ inflated Rescue Boat with four point lift arrangement – Type: “SB-420”

RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by as amended. IMO MSC./ Circular 1006. ISO 15372 (2000)

Expires: 23 May 2021

MED 1650153/ M1

6/ 8 persons outboard powered davit-launched rigid/ inflated rescue boat - Type: “SV-750”

Rescue Boats IMO Resolution MSC.81 (70), Part 1 as amended by IMO Resolution MSC. 226(82), MSC.274(85) and MSC.321 (89) IMO MSC/ Circ.1006 ISO 15372:2000

Expires: 14 March 2022

MED 1750048

Pascoe International Ltd, Boat Shed 3, Universal M arina, Crableck Lane, Southampton, SO31 7ZN, United Kingdom (UK).

6 Person rigid inflatable Rescue Boat w ith inherent buoyancy powered by water jet Yanmar 260 HP – Type “ Rescue Tender 7.0m SOLAS”

INFLATED RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85) & MSC.323 (89).

O MSC./ Circular 1006 ISO 15372:2000

Expires: 25 October 2017

MED 1250217

“ 6 Person rigid inflatable Rescue Boat w ith inherent buoyancy powered by a Yanmar 260 HP inboard diesel engine and water jet – Type “ Rescue Tender 7.0 m”

RIGID/INFLATED RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85), MSC.323 (89) & MSC.321 (89).

O MSC/ Circular 1006 ISO 15372:2000

Expires: 4 November 2017

MED 1250229/ M4

6 Person rigid inflatable Rescue Boat powered by a Yanmar 180 HP inboard diesel engine and water jet – Type “ Rescue Tender 5.5m SOLAS” .

RIGID/INFLATED RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85) & MSC.323 (89).

O MSC/ Circular 1006. ISO 15372 (2000).

Expires: 4 June 2018

MED 1350077/ M1

Page 346: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.43 Rigid/Inflated Recue Boats

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

346 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

6 Person rigid inflatable Rescue Boat w ith inherent buoyancy powered by a Steyr 164 HP or Yanmar 180 HP inboard diesel engine and water jet – Type “ Shuttle 6.2” .

RIGID/INFLATED RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82), MSC.274 (85) & MSC.321 (89).

O MSC./ Circular 1006 ISO 15372:2000

Expires: 11 January 2019

MED 1450010/ M1

Vanguard (Nantong) F.R.P Co. Ltd, Tongzhou City, Sanyu Town, Nantong, Jiangsu Province, 226331, China, People's Republic of.

Rigid Fast Rescue Boat with inherent buoyancy Type: “ VG6.0 FRW / FRK”

RIGID FAST RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by IMO Resolution MSC.226 (82), MSC.274 (85) & MSC.321 (89). IMO MSC/ CIRC.1006

Expires: 20 September 2017

MED 1250169/ M2

Page 347: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.43 Rigid/Inflated Recue Boats

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

347 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Vanguard M arine LDA, Zona Industrial No. 1 Campos, 4920-012 Vilanova De Cerveira, Viana, Portugal.

6 Persons Rigid/ Inflated Rescue Boat Type; “ SOLAS 420” .

RIGID/INFLATED RESCUE BOAT IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82). MSC.274 (85), MSC.323 (89) & MSC.320 (89). ISO 15372 (2000).

Expires: 1 September 2019

MED 1450178/ M2

Wahoo Ribs Ltd., Town Quay House, 99 Gosport Road, Fareham, PO16 0PY, United Kingdom (UK).

6 person single fall davit launched rigid / inflated rescue boat– Type: “Wahoo SOLAS 6.2”

RIGID/INFLATED RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended. IMO MSC/ Circular 1006 ISO 15372:2000

Expires: 8 January 2022

MED 1750001

Work Ribs Holland BV, Het Nieuwe Werk 40, 1781 AL Den Helder, Netherlands, The.

15 person davit launched inboard diesel powered self-righting rigid/ inflatable fast rescue boat – Type: “ WRH 735 FRB”

FAST RESCUE BOATS IMO Resolution MSC.81 (70), Part 1 as amended by Resolution MSC.226 (82) and MSC.274 (85) and MSC.323 (89) MSC/ Circ. 1006 ISO 15372 (2000)

Expires: 8 October 2017

MED 1250192/ M1

Zodiac Hurricane Technologies Inc., 7830 Vantage Way, Delta, British Columbia, V4G 1A7, Canada.

6 persons inboard powered davit-launched rigid/ inflated rescue boat – Type: “ P561DJ Proluxe”

Rescue Boats IMO Resolution MSC.81 (70), Part 1 as amended by MSC 226(82), MSC 274(85) and MSC/ Circ 1006 and ISO 15372

Expires: 8 July 2020

MED 1550161

Page 348: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.5 IM M ERSION SUITS & ANTI-EXPOSURE SUITS DESIGNED TO BE WORN IN CONJUNCTION WITH A LIFEJACKE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

348 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Sagitarrius Sporting Goods, No 60 Lane 908, Feng Lin 2nd Road, Ta Liao, Kaohsiung, Taiwan.

Insulated immersion suit to be worn together w ith an approved lifejacket - Type: “ OSS Insulated Immersion Suit”

Immersion Suits IMO Resolution MSC.81(70), Part 1, as amended by resolution MSC 226(82)

Expires: 31 January 2016

MED 1150051

Survitec Services & Distribution Ltd. trading as Crewsaver, Crewsaver, M umby Road, Gosport, Hampshire, PO12 1AQ, United Kingdom (UK).

Insulated immersion suit to be worn together w ith an approved lifejacket - Type: “ Crewsaver 8800 Adult”

IMMERSION SUITS IMO Resolution MSC.81 (70), Part 1 as amended by Resolution MSC.226 (82).

Expires: 6 June 2017

MED 1250083

Insulated immersion suit to be worn together w ith an approved lifejacket - Type: “ Regatta Immersion Suit”

Immersion Suits IMO Resolution MSC.81(70), Part 1, as amended by resolution MSC 226(82)

Expires: 11 July 2020

MED 1550186

Insulated immersion suit to be worn together w ith an approved lifejacket - Type: “ Crewsaver 8800 Child”

IM M ERSION SUITS IMO Resolution MSC.81(70), Part 1 as amended by Resolution MSC.226 (82) and MSC.323 (89)

Expires: 15 March 2021

MED 1650063

TakashinaLifePreserversCoLtd, 1-1-30KuboyoshiNaniwaKu, Osaka, 556-0028, Japan.

Insulated non-buoyant immersion suit to be worn w ith an approved lifejacket – Type: “ TK-007IN (Adult Universal)”

Immersion Suits IMO Resolution MSC.81(70), as amended by MSC 200(80), MSC 226(82) and MSC 323(89)

Expires: 11 July 2021

MED 1650161/ M1

Page 349: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.5 IM M ERSION SUITS & ANTI-EXPOSURE SUITS DESIGNED TO BE WORN IN CONJUNCTION WITH A LIFEJACKE

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

349 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

The Coleman Company, Inc., 3600 N Hydraulic, Wichita, KS 67226, United States of America (USA).

Insulated immersion suit without head collar to be worn together with an approved lifejacket – Type: “I590C”

Immersion Suits And Anti-Exposure Suits - Insulated

The LSA Code, Regulations I/ 1.2 and II/ 2.3.1, II/ 2.3.2 as amended by resolution MSC 207(81). IMO Resolution MSC.81(70), Part 1, as amended by resolution MSC 226(82)

Expires: 5 February 2019

MED 1450106

Page 350: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.6 IM M ERSION SUITS & ANTI EXPOSURE SUITS DESIGNED TO BE WORN WITHOUT A LIFEJACKET - INSULA

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

350 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ustang Survival ULC, 7525 Lowland Drive, Burnaby, BC, V5J 5L1, Canada.

Inherently buoyant insulated immersion suit w ith inflatable buoyant head support - Type: “ OC8003vHR“

IM M ERSION SUITS IMO Resolution MSC.81 (70) as amended by MSC.226 (82)

Expires: 16 July 2018

MED 1350096/ M1

Inherently buoyant insulated immersion suit w ith inflatable buoyant head support - Type: “ OC8000 HR“

Immersion Suits IMO Resolution MSC.81 (70), Part 1 as amended by MSC 226(82) and MSC.323 (89)

Expires: 9 January 2021

MED 1650076

Inherently buoyant insulated immersion suit w ith inflatable buoyant head support - Types: “ M IS210 HR, M IS220 HR, M IS230 HR and M IS240 HR“

INSULATED IM M ERSION SUIT IMO Resolution MSC.81(70) as amended by MSC 226(82) and MSC 323(89).

Expires: 28 November 2020

MED 1650111

Survitec Service & Distribution Ltd t/a Crewsaver, Survitec House, Lederle Lane, Gosport, Hampshire, PO13 0FZ, United Kingdom (UK).

Insulated Immersion Suits to be worn WITHOUT a Lifejacket – Type “Regatta 8804-(B) Adult fitted with Buoyancy Plus”

IM M ERSION SUITS IMO Resolution MSC.81 (70), Part 1 as amended by Resolution MSC.226 (82) and MSC.323 (89)

Expires: 21 February 2021

MED 1650078/ M1

Survitec Services & Distribution Trading as Crewsaver, Survitec House, Lederle Lane, Gosport, PO13 0FZ, United Kingdom (UK).

Insulated Immersion Suits to be worn WITHOUT a Lifejacket – Type “Crewsaver 8800-(B) Adult fitted with Buoyancy Plus”

IM M ERSION SUITS IMO Resolution MSC.81 (70), Part 1 as amended by Resolution MSC.226 (82) and MSC.323 (89)

Expires: 21 February 2021

MED 1650077

Page 351: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.6 IM M ERSION SUITS & ANTI EXPOSURE SUITS DESIGNED TO BE WORN WITHOUT A LIFEJACKET - INSULA

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

351 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

TakashinaLifePreserversCoLtd, 1-1-30KuboyoshiNaniwaKu, Osaka, 556-0028, Japan.

Inherently buoyant insulated immersion suit w ith buoyant head support – Type “ TK-007SE” (Adult Universal & Oversize).

Immersion Suit w ith inherent insulation.

IMO Resolution MSC.81 (70), Part1 as amended by Resolution MSC.226 (82) & MSC.323 (89).

Expires: 25 April 2020

MED 1550142

The Coleman Company, Inc., 3600 N Hydraulic, Wichita, KS 67226, United States of America (USA).

Insulated immersion suit with manually inflatable collar; can be used without additional lifejacket under administration instruction. Type: “I590”

Immersion Suits & Anti-Exposure Suits – Insulated

The LSA Code, Regulations I/ 1.2 and II/ 2.3.1, II/ 2.3.2 as amended by resolution MSC 207(81). IMO Resolution MSC.81(70), Part 1, as amended by resolution MSC 226(82)

Expires: 5 February 2019

MED 1450104

Page 352: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.7 THERM AL PROTECTIVE AIDS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

352 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lalizas Hellas, 3 Gounari Street, 185 31 Piraeus, Greece.

Thermal Protective Aids suitable for use in survival craft only – Type: “Alusafe –T

Thermal Protective Aids IMO Resolution MSC.81 (70), Part 1 as amended by MSC.200 (80), MSC.226 (82) and MSC.323 (89)

Expires: 24 August 2020

MED 1550153/ M1

Xiantao Deming Healthcare Products Co., Ltd, No.198, Pengchang Ave, Xiantao City, Hubei, China, People's Republic of.

Thermal Protective Aids suitable for use in survival craft only- Type:” MF206D”

THERM AL PROTECTIVE AIDS IMO Resolution. MSC.81 (70) Part 1 as amended.

Expires: 2 February 2020

MED 1550036

Page 353: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.8 ROCKET PARACHUTE FLARES (PYROTECHNICS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

353 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Drew M arine Signal & Safety Spain SL, Camino M endi S/N, Esquiroz de Galar, Navarra, 31191, Spain.

Rocket Parachute Flare – Type: “ Rocket Parachute Flare, Red, Article OROC 001” .

PYROTECHNICS IMO Resolution MSC.81 (70), Part 1 as amended by MSC. 226 (82).

Expires: 4 January 2021

MED 1650090

Page 354: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Life-saving appliances Product: M ED/1.9 HAND FLARES (PYROTECHNICS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

354 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Drew M arine Signal & Safety Spain SL, Camino M endi S/N, Esquiroz de Galar, Navarra, 31191, Spain.

Hand flare (Pyrotechnics) – Type: “ ORO B001”

Pyrotechnics IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82)

Expires: 10 January 2017

MED 1250004/ M1 & USCG NO. 160.121

Hand flare (Pyrotechnics) – Type: “ CHIM I”

PYROTECHNICS IMO Resolution MSC.81 (70), Part 1 as amended by MSC.226 (82).

Expires: 22 January 2021

MED 1650088

Page 355: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.1 OIL-FILTERING EQUIPM ENT (FOR AN OIL CONTENT OF THE EFFLUENT NOT EXCEEDING 15 PPM )

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

355 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Aalandia GmbH, Baumstraße 62-66, 28217 Bremen, Germany.

MariPower 1.0 Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49)

Expires: 15 October 2017

MED 1250218

MariPower 4.0 Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49)

Expires: 15 October 2017

MED 1250219

Environmental Protection Engineering S.A., 24 Dervenakion Street, 185 45 Piraeus, Greece.

Poseidon FIT PF 5.0 OIL FILTERING EQUIPM ENT (POLLUTION PREVENTION)

IMO Resolution MEPC.107(49) Expires: 16 April 2020

MED 1550084

Poseidon FIT PF 0.25 OIL FILTERING EQUIPM ENT (POLLUTION PREVENTION)

IMO Resolution MEPC.107(49) Expires: 16 April 2020

MED 1550104

Poseidon FIT PF 0.5 OIL FILTERING EQUIPM ENT (POLLUTION PREVENTION)

IMO Resolution MEPC.107(49) Expires: 16 April 2020

MED 1550105

Poseidon FIT PF 1.0 OIL FILTERING EQUIPM ENT (POLLUTION PREVENTION)

IMO Resolution MEPC.107(49) Expires: 16 April 2020

MED 1550106

Poseidon FIT PF 2.0 OIL FILTERING EQUIPM ENT (POLLUTION PREVENTION)

IMO Resolution MEPC.107(49) Expires: 16 April 2020

MED 1550107

Poseidon FIT PF 2.5 OIL FILTERING EQUIPM ENT (POLLUTION PREVENTION)

IMO Resolution MEPC.107(49) Expires: 16 April 2020

MED 1550108

Poseidon FIT PF 7.5 OIL FILTERING EQUIPM ENT (POLLUTION PREVENTION)

IMO Resolution MEPC.107(49) Expires: 16 April 2020

MED 1550109

Poseidon FIT PF 10.0 OIL FILTERING EQUIPM ENT (POLLUTION PREVENTION)

IMO Resolution MEPC.107(49) Expires: 16 April 2020

MED 1550110

Page 356: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.1 OIL-FILTERING EQUIPM ENT (FOR AN OIL CONTENT OF THE EFFLUENT NOT EXCEEDING 15 PPM )

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

356 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Environmental Protection Engineering SA, 24, Dervenakion Street, Piraeus 18545, Greece.

Poseidon EVO PE 0.5 OIL FILTERING EQUIPM ENT (POLLUTION PREVENTION)

IMO Resolution MEPC.107(49) Expires: 24 October 2018

MED 1350138

Poseidon EVO PE 1.0 Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49)

Expires: 1 June 2021

MED 1650174

Poseidon EVO PE 2.5 Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49)

Expires: 1 June 2021

MED 1650175

Page 357: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.1 OIL-FILTERING EQUIPM ENT (FOR AN OIL CONTENT OF THE EFFLUENT NOT EXCEEDING 15 PPM )

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

357 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Environmental Protection Engineering SA ...continued

Poseidon EVO PE 5.0 Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49)

Expires: 1 June 2021

MED 1650176

Poseidon EVO PE 7.5 Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49) Expires: 1 June 2021

MED 1650177

Poseidon EVO PE 10.0 Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49)

Expires: 1 June 2021

MED 1650178

Flight Refuelling Ltd., trading as Cobham M ission Equipment, Brook Road, Wimborne, Dorset, BH21 2BJ, United Kingdom (UK).

Oily Water Separator – Type: “ TX1918” Oil-Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49) Expires: 31 May 2015

MED 1050125/ M1

Promac B.V, Van Voordenpark 14, 5301 KP Zaltbommel, Netherlands, The.

Aquacleaner MAR-C-240 Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49) Expires: 22 April 2015

MED 1050084

Aquacleaner MAR-C-480 Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49) Expires: 22 April 2015

MED 1050085

Aquacleaner MAR-C-60 Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49) Expires: 19 May 2015

MED 1050086

Aquacleaner MAR-C-35 Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49) Expires: 22 April 2015

MED 1050087

“ Aquacleaner MAR-C-120” OIL FILTERING EQUIPMENT (POLLUTION PREVENTION)

IMO Resolution MEPC.107(49) Expires: 11 April 2022

MED 1750065

Page 358: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.1 OIL-FILTERING EQUIPM ENT (FOR AN OIL CONTENT OF THE EFFLUENT NOT EXCEEDING 15 PPM )

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

358 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai M arine Equipment Research Institute, No. 10 Hengshan Road, Xuhui District, Shanghai, 200031, China, People's Republic of.

Bilge Separator – Type: “ CYZ-0.25” Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49) Expires: 21 August 2016

MED 1150230

Bilge Separator – Type: “ CYZ-0.5” Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49) Expires: 21 August 2016

MED 1150231

Bilge Separator – Type: “ CYZ-1.0” Oil Filtering Equipment (Pollution Prevention)

IMO Resolution MEPC.107(49) Expires: 21 August 2016

MED 1150232

Page 359: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.1 OIL-FILTERING EQUIPM ENT (FOR AN OIL CONTENT OF THE EFFLUENT NOT EXCEEDING 15 PPM )

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

359 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai M arine Equipment Research Institute ...continued

Bilge Separator – Type: “ CYZ-2.0” Oil filtering equipment (pollution prevention)

IMO Resolution MEPC.107(49) Expires: 21 August 2016

MED 1150233

Bilge Separator – Type: “ CYZ-3.0” Oil filtering equipment (pollution prevention)

IMO Resolution MEPC.107(49) Expires: 21 August 2016

MED 1150234

Bilge Separator – Type: “ CYZ-3.5” Oil filtering equipment (pollution prevention)

IMO Resolution MEPC.107(49) Expires: 21 August 2016

MED 1150235

Bilge Separator – Type: “ CYZ-5.0” Oil filtering equipment (pollution prevention)

IMO Resolution MEPC.107(49) Expires: 21 August 2016

MED 1150236

Page 360: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.2 OIL/WATER INTERFACE DETECTOR

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

360 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai Rongde Engineering Equipment Co., Ltd., RM 1401, Xingyu Building No.1 - 1695, Pudong Ave, Shanghai, China, People's Republic of.

UIT-100 AND UIT-200 PORTABLE OIL/WATER INTERFACE DETECTOR

IMO Resolution MEPC.5 (XIII) Expires: 29 July 2019

MED 1450167

Page 361: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.5 OIL DISCHARGE M ONITORING AND CONTROL SYSTEM FOR AN OIL TANKER

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

361 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai Rongde Engineering Equipment Co., Ltd., RM 1401, Xingyu Building No.1 - 1695, Pudong Ave, Shanghai, China, People's Republic of.

Type: “ RD-ODME-IIA OIL DISCHARGE M ONITORING AND CONTROL SYSTEM S (POLLUTION PREVENTION)

IMO Resolution MEPC.108 (49) Expires: 18 February 2019

MED 1450038/ M1

Page 362: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

362 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Act2 Technologies, 3778 SW 30th Ave, Fort Lauderdale, Florida 33312, United States of America (USA).

“ WRS-6” Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 16 August 2015

MED 1050216

“ WRS-8” Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 16 August 2015

MED 1050217

Environmental Protection Engineering S A, Schisto Industrial Park (VIPAS), Block 13, Keratsiniou-Skaramggkas, 18863 Perama, Geece, Greece.

“ ORCA IV 50C” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 23 March 2022

MED 1750056

Environmental Protection Engineering S.A., 24 Dervenakion Street, 185 45 Piraeus, Greece.

Triton Evo 8 Sewage Treatment Plants (Pollution Prevention)

MEPC.159 (55) Expires: 27 April 2016

MED 1150128

Environmental Protection Engineering S.A., Schisto Industrial Park (Vipas), Block 13, Keratsiniou-Skaramagkas Avenue, 18863 Perama, Greece.

“ TRITON µ 300” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 8 January 2020

MED 1550009

Page 363: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

363 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

“ TRITON µ 500” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 17 March 2020

MED 1550062

Environmental Protection Engineering S.A., 24 Dervenakion Street, 185 45 Piraeus, Greece.

“ TRITON EC 50” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 2 December 2020

MED 1550265

“ TRITON EC 700” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 2 December 2020

MED 1550266

Page 364: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

364 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Environmental Protection Engineering S.A. ...continued

“ TRITON EC 300” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 2 December 2020

MED 1550267

“ TRITON EC 600” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 2 December 2020

MED 1550268

“ TRITON EC 500” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 2 December 2020

MED 1550269

“ TRITON EC 35” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 2 December 2020

MED 1550270

“ TRITON EC 200” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 2 December 2020

MED 1550271

“ TRITON EC 15” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 2 December 2020

MED 1550272

“ TRITON EC 65” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 2 December 2020

MED 1550273

“ TRITON EC 100” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 2 December 2020

MED 1550274

Environmental Protection Engineering SA, 24 DERVENAKION STR, PIRAEUS, 18545, Greece.

“ TRITON EC NP 15” SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 18 January 2021

MED 1650024

“ TRITON EC NP 35” SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 18 January 2021

MED 1650025

“ TRITON EC NP 50” SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 18 January 2021

MED 1650026

Page 365: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

365 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

“ TRITON EC NP 65” SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 18 January 2021

MED 1650027

“ TRITON EC NP 100” SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 18 January 2021

MED 1650028

“ TRITON EC NP 200” SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 18 January 2021

MED 1650029

“ TRITON EC NP 300” SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 18 January 2021

MED 1650030

Page 366: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

366 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Environmental Protection Engineering SA ...continued

“ TRITON EC NP 500” SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 18 January 2021

MED 1650031

“ TRITON EC NP 600” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 20 January 2021

MED 1650032

“ TRITON EC NP 700” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 18 January 2021

MED 1650033

Evac Oy, Sinimäentie 14, FIN-02630 Espoo, Finland.

“ ORCA III 300” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 8 January 2020

MED 1550008

“ ORCA III 500” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 17 March 2020

MED 1550061

“ ORCA III 15” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 7 November 2020

MED 1650004

“ ORCA III 35” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 7 November 2020

MED 1650005

“ ORCA III 50” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 7 November 2020

MED 1650006

“ ORCA III 65” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 7 November 2020

MED 1650008

“ ORCA III 100” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 7 November 2020

MED 1650009

“ ORCA III 200” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 7 November 2020

MED 1650010

Page 367: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

367 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Hamworthy Waste Water Systems Limited, Fleets Corner, Poole, Dorset, BH17 0JT, United Kingdom (UK).

Expires: 6 August 2008

MED 0350208

Page 368: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

368 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Holland M arine Services Amsterdam B.V., Vlothavenweg 16, 1013BJ Amsterdam, Netherlands, The. Licence L95/00060

MSD-III Series Advanced Waste Water Treatment unit, Consisting: MSD-III/ 10, MSD-III/ 20, MSD-III/ 30, MSD-III/ 40, MSD-III/ 50, MSD-III/ 60, MSD-III/ 70, MSD-III/ 80, MSD-III/ 100, MSD-III/ 120, MSD-III/ 140, MSD-III/ 160, MSD-III/ 200, MSD-III/ 240, MSD-III/ 280, MSD-III/ 320, MSD-III/ 400

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 22 December 2020

MED 1550298

MSD-III-VAC/ 10, MSD-III-VAC/ 20, MSD-III-VAC/ 30, MSD-III-VAC/ 40, MSD-III-VAC/ 50, MSD-III-VAC/ 60, MSD-III-VAC/ 70, MSD-III-VAC/ 80, MSD-III-VAC/ 100, MSD-III-VAC/ 120, MSD-III-VAC/ 140, MSD-III-VAC/ 160, MSD-III-VAC/ 200, MSD-III-VAC/ 240, MSD-III-VAC/ 280, MSD-III-VAC/ 320, MSD-III-VAC/ 400

ISIR Impianti S.r.l, Via M ilano 166D rosso, 16126 Genova GE, I taly.

AWWTP MK3 – 50 TPD SEWAGE TREATMENT PLANTS IMO RESOLUTION MEPC.159(55) Expires: 22 November 2017

MED 1250244

Shanghai M arine Equipment Research Institute, No. 10 Hengshan Road, Xuhui District, Shanghai, 200031, China, People's Republic of.

M BR-50 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

Sewage Treatment Plants MEPC. 159(55) Expires: 5 August 2019

MED 1450204

Page 369: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

369 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M BR-20 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

Sewage Treatment Plants MEPC. 159(55) Expires: 5 August 2019

MED 1450205

M BR-30 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

Sewage Treatment Plants MEPC. 159(55) Expires: 5 August 2019

MED 1450206

Page 370: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

370 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai M arine Equipment Research Institute ...continued

M BR-40 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450207

M BR-60 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450208

M BR-70 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450209

M BR-80 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450210

M BR-90 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450211

M BR-100 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450212

Page 371: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

371 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M BR-120 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450213

Page 372: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

372 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai M arine Equipment Research Institute ...continued

M BR-150 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450214

M BR-200 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450215

M BR-250 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450216

M BR-300 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450217

M BR-350 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450218

Page 373: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

373 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M BR-400 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450219

M BR-500 Sewage Treatment Plant (Pollution Prevention): Marine Sanitation Device with Sequencing Batch and Membrane Biological Treatment System

SEWAGE TREATM ENT PLANTS MEPC. 159(55) Expires: 5 August 2019

MED 1450220

Page 374: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

374 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

SludgeHammer Group Ltd., 336 S. Division Rd., Petoskey, M I 49770, United States of America (USA).

SludgeHammer MS Series – Marine Wastewater Treatment Systems: Model No. “ MS – Prototype”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

IMO RES. MEPC.159(55) Expires: 28 September 2019

MED 1450184

SludgeHammer MS Series – Marine Wastewater Treatment Systems: Model No. “ MS – 700”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

IMO RES. MEPC.159(55) Expires: 28 September 2019

MED 1450185

Tecnicomar S.p.A., C/da Berbaro, 145/D, 91025 M arsala (TP), I taly.

“ ECOMAR 6” Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 17 February 2015

MED 1050045

“ ECOMAR 6AC” Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 17 February 2015

MED 1050046

“ ECOMAR 8” Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 17 February 2015

MED 1050047

“ ECOMAR 8AC” Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 17 February 2015

MED 1050048

“ ECOMAR 16” Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 17 February 2015

MED 1050049

“ ECOMAR 24” Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 17 February 2015

MED 1050050

“ ECOMAR 50” Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 17 February 2015

MED 1050051

Page 375: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

375 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

“ ECOMAR 120” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 159(55) Expires: 17 February 2020

MED 1550047

“ ECOMAR 200” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 16 June 2020

MED 1550146/ M1

“ ECOMAR 20” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), including para 4.2 Expires: 21 December 2020

MED 1550293

“ ECOMAR 32” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), including para 4.2 Expires: 21 December 2020

MED 1550294

“ ECOMAR 45” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), including para 4.2 Expires: 21 December 2020

MED 1550295

Page 376: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

376 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Tecnicomar S.p.A. ...continued

“ ECOMAR 70” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), including para 4.2 Expires: 21 December 2020

MED 1550296

“ ECOMAR 145” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), including para 4.2 Expires: 21 December 2020

MED 1550297

“ ECOMAR 340” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), including para 4.2 Expires: 13 January 2021

MED 1650019

“ ECOMAR 545” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), including para 4.2 Expires: 13 January 2021

MED 1650020

Wartsila Water Systems Ltd., Fleets Corner, Poole, Dorset, BH17 0JT, United Kingdom (UK).

Hamworthy Membrane Bio Reactor (MBR) Waste Treatment Plant – Model “ MBR 6”

Sewage Treatment Plants MEPC. 159(55) Expires: 9 March 2015

MED 1050054

Hamworthy Membrane Bio Reactor (MBR) Waste Treatment Plant – Model “ AWTP M BR 6”

Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 3 August 2015

MED 1050193

Hamworthy Membrane Bio Reactor (MBR) Waste Treatment Plant – Model “ MBR 12”

Sewage Treatement Plants (Pollution Prevention)

MEPC. 159(55) Expires: 15 August 2015

MED 1050203

Hamworthy Membrane Bio Reactor (MBR) Waste Treatment Plant – Model “ MBR 200N”

Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 11 August 2015

MED 1050212

Hamworthy Membrane Bio Reactor (MBR) Waste Treatment Plant – Model “ MBR 32”

Sewage Treatment Plants (Polltion Prevention)

MEPC. 159(55) Expires: 11 August 2015

MED 1050213

Page 377: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

377 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Hamworthy Membrane Bio Reactor (MBR) Waste Treatment Plant – Model: “ MINI MBR6”

Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 17 April 2016

MED 1150119

Hamworthy Membrane Bio Reactor (MBR) Waste Treatment Plant – Model “ MBR 24”

Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 17 October 2016

MED 1150283

Hamworthy Membrane Bio Reactor (MBR) Waste Treatment Plant – Model: “ M BR 30”

Sewage Treatment Plants (Pollution Prevention)

MEPC. 159(55) Expires: 25 October 2016

MED 1150289

Enhanced Super Trident – Type: ST2A-CR

SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.159 (55) Expires: 14 March 2017

MED 1250037/ M1

Enhanced Super Trident – Type: ST4A-CR

SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.159 (55) Expires: 14 March 2017

MED 1250038/ M1

Page 378: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

378 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wartsila Water Systems Ltd. ...continued

Enhanced Super Trident – Type: ST6A-CR

SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.159 (55) Expires: 14 March 2017

MED 1250039/ M1

Enhanced Super Trident – Type: ST8-CR

SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.159 (55) Expires: 14 March 2017

MED 1250040/ M1

Hamworthy Membrane Bio Reactor (MBR) Waste Treatment Plant – Model “ MBR 16”

SEWAGE TREATMENT PLANTS MEPC. 159(55) Expires: 16 May 2017

MED 1250091

Enhanced Super Trident Type: ST2A-C Sewage Treatment Plants (Pollution Preventions)

MEPC.159 (55) Expires: 24 September 2017

MED 1250175

ENHANCED SUPER TRIDENT – TYPE: “ ST20-C”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 159(55) Expires: 18 October 2017

MED 1250200

Enhanced Super Trident – Type: ST8-QUAD

SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.159 (55) Expires: 18 October 2017

MED 1250201

Enhanced Super Trident Type: ST1A-C

Sewage Treatment Plants (Pollution Prevention)

MEPC.159 (55) Expires: 27 March 2013 MED 0850068

Enhanced Super Trident – Type: “STC02”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159 (55) Expires: 21 October 2017

MED 1250204

Enhanced Super Trident – Type: “STC03”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159 (55) Expires: 21 October 2017

MED 1250205

Enhanced Super Trident – Type: “STC04”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159 (55) Expires: 21 October 2017

MED 1250206

Enhanced Super Trident – Type: “STC06”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159 (55) Expires: 21 October 2017

MED 1250207

Page 379: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

379 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

SUPER TRIDENT – TYPE: “ ST8-C” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 159(55) Expires: 21 October 2017

MED 1250208

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

SUPER TRIDENT – TYPE: “ ST10-C” MEPC. 159(55) Expires: 21 October 2017

MED 1250209

SUPER TRIDENT – TYPE: “ ST13-C” SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 159(55) Expires: 21 October 2017

MED 1250210

ENHANCED SUPER TRIDENT – TYPE: “ ST15-C”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 159(55) Expires: 21 October 2017

MED 1250211

ENHANCED SUPER TRIDENT – TYPE: “ ST30-C”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 159(55) Expires: 21 October 2017

MED 1250212

Page 380: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

380 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wartsila Water Systems Ltd. ...continued

ENHANCED SUPER TRIDENT – TYPE: “ ST40-C”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

IMO RES. MEPC. 159(55) Expires: 21 October 2017

MED 1250213

ENHANCED SUPER TRIDENT – TYPE: “ ST50-C”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

IMO RES. MEPC. 159(55) Expires: 21 October 2017

MED 1250214

ENHANCED SUPER TRIDENT – TYPE: “ ST60-C”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

IMO RES. MEPC. 159(55) Expires: 21 October 2017

MED 1250215

ENHANCED SUPER TRIDENT – TYPE: “ ST25-C”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 159(55) Expires: 21 October 2017

MED 1250216

Enhanced Super Trident – Type: “ ST3A-C”

Sewage Treatment Plants (Pollution Prevention)

MEPC.159 (55) Expires: 6 February 2013

MED 0850029

Enhanced Super Trident Type: ST4A-C Sewage Treatment Plants (Pollution Prevention)

MEPC.159 (55) Expires: 27 March 2013 MED 0850069

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

Enhanced Super Trident – Type: “ST6A-C”

MEPC.159 (55) Expires: 11 November 2017

MED 1250237

ENHANCED SUPER TRIDENT – TYPE: “ ST25X”

SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC. 159(55) Expires: 8 August 2018

MED 1350107

Hamworthy Membrane Bio Reactor (MBR) Water Treatment Plant – Model: “ MBR2”

SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 13 August 2018

MED 1350109

Enhanced Super Trident – Type: “STC02-13”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 30 January 2019

MED 1450018

Enhanced Super Trident – Type: “STC03-13”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 30 January 2019

MED 1450019

Page 381: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

381 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Enhanced Super Trident – Type: “STC04-13”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 30 January 2019

MED 1450020

Enhanced Super Trident – Type: “STC06-13”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64) Expires: 30 January 2019

MED 1450021

ENHANCED SUPER TRIDENT – TYPE: STC50-OFON

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

IMO RES. MEPC. 159(55) Expires: 29 May 2019

MED 1450123

Hamworthy Membrane Bio Reactor (MBR) Waste Treatment Plant – Model “ MBR 16 II”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 159(55) Expires: 8 January 2020

MED 1550006

Page 382: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

382 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wartsila Water Systems Ltd. ...continued

Hamworthy Membrane Bio Reactor (MBR) Water Treament Plant – Model: “ MBR4”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.159(55) Expires: 8 January 2020

MED 1550007

Enhanced Super Trident – Type: RTC20-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550022

Enhanced Super Trident – Type: RTC40-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550023

Enhanced Super Trident – Type: RTC60-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550024

Enhanced Super Trident – Type: RTC80-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550025

Enhanced Super Trident – Type: STC08-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550026

Enhanced Super Trident – Type: STC10-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550027

Enhanced Super Trident – Type: STC13-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 227(64), excluding para 4.2 Expires: 29 January 2020

MED 1550028

Enhanced Super Trident – Type: STC15-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550029

Enhanced Super Trident – Type: STC20-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550030

Enhanced Super Trident – Type: STC25-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550031

Enhanced Super Trident – Type: STC30-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550032

Page 383: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

383 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Enhanced Super Trident – Type: STC40-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550033

Enhanced Super Trident – Type: STC50-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550034

Enhanced Super Trident – Type: STC60-14

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 29 January 2020

MED 1550035

Hamworthy Membrane Bio Reactor (MBR) Water Treament Plant – Model: “ mini MBR6”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), excluding para 4.2 Expires: 8 February 2020

MED 1550038

Page 384: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

384 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wartsila Water Systems Ltd. ...continued

Enhanced Super Trident – Type: STC01-13

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 227(64), excluding para 4.2 Expires: 3 March 2020

MED 1550051/ M1

Enhanced Super Trident – Type: STC02-13

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 227(64), excluding para 4.2 Expires: 3 March 2020

MED 1550052

Enhanced Super Trident – Type: STC03-13

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 227(64), excluding para 4.2 Expires: 3 March 2020

MED 1550053

Enhanced Super Trident – Type: STC04-13

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 227(64), excluding para 4.2 Expires: 3 March 2020

MED 1550054

Enhanced Super Trident – Type: STC06-13

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC. 227(64), excluding para 4.2 Expires: 3 March 2020

MED 1550055

Hamworthy Membrane Bio Reactor (MBR) Water Treatment Plant – Model: “ MBR8”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 5 November 2020

MED 1550250

Hamworthy Membrane Bio Reactor (MBR) Water Treatment Plant – Model: “ MBR 200N”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 18 November 2020

MED 1550257

Hamworthy Membrane Bio Reactor (MBR) Water Treatment Plant – Model: “ MBR 16 II”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 13 December 2020

MED 1550280

Hamworthy Membrane Bio Reactor (MBR) Water Treatment Plant – Model: “ MBR 4”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227 (64), excluding para 4.2 Expires: 13 December 2020

MED 1550281

Enhanced Super Trident – Type: ST50-C EGINA

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

IMO MEPC.159 (55) Expires: 20 December 2020

MED 1550292

Page 385: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

385 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Membrane Bio-Reactor (MBR) Waste Treatment Plant – Model: “ M BR16 97740”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), excluding para 4.2 Expires: 9 March 2021

MED 1650094

Membrane Bio-Reactor (MBR) Waste Treatment Plant – Model: “ MBR8 GO98873”

SEWAGE TREATMENT PLANTS (POLLUTION PREVENTION

MEPC.227(64), excluding para 4.2 Expires: 6 November 2021

MED 1650263

Membrane Bio-Reactor (MBR) Waste Treatment Plant – Model: “ MBR12 GO98894”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), excluding para 4.2 Expires: 26 February 2022

MED 1750028

Page 386: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.6 SEWAGE SYSTEM S

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

386 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wartsila Water Systems Ltd. ...continued

Membrane Bio-Reactor (MBR) Waste Treatment Plant – Model: “ MBR24 GO98712”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), excluding para 4.2 Expires: 26 February 2022

MED 1750029

Membrane Bio-Reactor (MBR) Waste Treatment Plant – Model: “ MBR12”

SEWAGE TREATM ENT PLANTS (POLLUTION PREVENTION)

MEPC.227(64), excluding para 4.2 Expires: 27 February 2022

MED 1750030

Page 387: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.7 SHIPBOARD INCINERATORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

387 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

3 M aj Tibo d.d., Dalmatinskih Brigada 17, 51211 M atulji, Croatia.

Type SM 550 and SM 550-P

Shipboard incinerator:

MARPOL 73/ 78 Annex VI IMO resolution MEPC.76(40)

Expires: 29 August 2015

MED 0500042/ M1

SH-20SR SH-20SR-P SH-20SM SH-20SM-P

Shipboard Incinerators Marpol 73/ 78 Annex VI MEPC 76(40)

Expires: 19 May 2015

MED 9900011/ M2

Deerberg Systems, M oltkestraße 6a, 26122 Oldenburg, Germany.

DS 800 – DS 1400 SHIPBOARD INCINERATORS (POLLUTION PREVENTION)

MARPOL Annex VI, Regulation 16.6.1; IMO Resolution MEPC.244(66)

Expires: 15 February 2020

MED 1500018

DS 400 – DS 600

Shipboard Incinerator: Thermal Capacities (kW): 400-600

MARPOL Annex VI, Regulation 16.6.1; IMO Resolution MEPC 244(66)

Expires: 19 September 2020

MED 1600004/ M1

DS 1600 to DS 2400 Shipboard Incinerator: Thermal Capacities (kW): 1600-2400

MARPOL Annex VI, Regulation 16.6.1; IMO Resolution MEPC 244(66)

Expires: 7 September 2020

MED 1600005/ M1

DS100-DS200 Shipboard Incinerator

MARPOL Annex VI, Regulation 16; IMO Resolution MEPC 244(66)

Expires: 24 May 2021

MED 1600009

DS 3000 - DS 4000 Shipboard Incinerator: Thermal Capacities (kW): 3000-4000

MARPOL Annex VI, Regulation 16.6.1; IMO Resolution MEPC 244(66)

Expires: 8 March 2021

MED 1650092

DS 3000 – DS 4000 incinerators fitted with ‘Fremo’ burners

SHIPBOARD INCINERATORS (POLLUTION PREVENTION)

MARPOL Annex VI, Regulation 16.6.1; IMO Resolution MEPC.244(66)

Expires: 2 May 2022

MED 1700010

Page 388: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.7 SHIPBOARD INCINERATORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

388 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M iura Co. Ltd, 7 Horie-Cho, M atsuyama, Ehime 799-2696, Japan.

BGW-20N, BGW-30N, BGW-50N, BGW-80N & BGW-100N

Shipboard Incinerators Marpol 73/ 78 Annex VI MEPC 76(40)

Expires: 21 June 2019

MED 1400008

Page 389: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.7 SHIPBOARD INCINERATORS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

389 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

PyroGenesis Canada Inc., 2000, William Street, Suite 200, M ontreal, Quebec, H3J 1R8, Canada.

Shipboard plasma arc waste destruction system: Types: PAWDS-500 PAWDS-1000 PAWDS-2000 PAWDS-3000

Types PAWDS-500, PAWDS-1000, PAWDS-2000 & PAWDS-3000: Maximum heat capacity (kW): Solid waste: Sludge oil: 458 338 915 675 1830 1350 2745 2025

MARPOL 73/ 78 Annex VI; IMO resolution MEPC.76(40)

Expires: 14 November 2016

MED 1100010

Ulmatec Pyro AS, Gamlem, 6280 Sovik, Norway.

Type SM 550 Shipboard incinerator:

MARPOL 73/ 78 Annex VI IMO resolution MEPC.76(40)

21 October 2011

MED 0500043/ M1

SM 550 SHIPBOARD INCINERATORS (POLLUTION PREVENTION)

MARPOL Annex VI, Regulation 16.6.1; IMO Resolution MEPC.244(66)

Expires: 29 August 2020

MED 1600013

SH-20SR/ SM SHIPBOARD INCINERATORS (POLLUTION PREVENTION)

MARPOL Annex VI, Regulation 16.6.1; IMO Resolution MEPC.244(66)

Expires: 2 November 2021

MED 1600014

Page 390: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M arine Pollution Prevention Product: M ED/2.8 NOx ANALYZER FOR USE ON BOARD AS PER NOx TECHNICAL CODE 2008

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

390 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M artek M arine Ltd, Adwick Park, M anvers, Rotherham, South Yorkshire, S63 5AB, United Kingdom (UK).

Evolution EMS Marine diesel exhaust gas monitoring system for use for the direct measurement method of on-board monitoring of NOx emissions in accordance with MARPOL Annex VI, Regulation 13 and the NOx Technical Code 2008.

MARPOL Annex VI, Regulation 13; IMO NOx Technical Code, 2008; IMO Resolution MEPC.103(49).

Expires: 24 April 2015

MED 1000022/ M1

Page 391: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

391 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

3M Company, 4501 Hwy South, Brownwood, Texas 76801, United States of America (USA).

A.1/ 130 Retro-reflective materials

Lloyds Register Verification 0038 MED 1350104 8 August 2013

X Expires: 31 July 2017

MED 1450166/ M1

Lloyd’s Register Verification 0038 MED 1350105 8 August 2013

X

Lloyds Register Verification 0038 MED 1350106 8 August 2013

X

3M Fire Protection Products, 3M Center, Building 230-1D-31, St. Paul, M N 55144-1000, United States of America (USA).

A.1/ 3.26a – Penetrations through “ A” class divisions (a) electric cable transits

Lloyd’s Register Verification 0038 MED 1550235 19.08.2015

X Expires: 17 June 2018

MED 1550222/ M1

ACTIONAIR, South Street, Whitstable, Kent, CT5 3DU, United Kingdom (UK).

A.1/ 3.22 Fire Dampers

Lloyd’s Register Verification 0038 MED 1250101& 13-Jun-2012

X Expires: 16 September 2019

MED 1650203

ADVANCED PNEUM ATIC M ARINE GM BH, Weddernkamp 6, 23858 Reinfeld, Germany.

A.1/ 3.17 Fire Door Control System Components

Lloyd’s Register Verification 0038 MED 1250149 30-May-2012

X Expires: 8 October 2019

MED 1650249

Page 392: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

392 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1250148/ M1 10/ 08/ 2016

X

RINA 0474 MED288813CS/ 002 14-March-2014

X

MED078515CS 10.06.2016

X

Page 393: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

393 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Aeroflex Co., Ltd., 111/7, 111/11 M u 2, Tambol M akhamku Amphur Nikompattana, Rayong 21180, Thailand.

A.1/ 3.18d Surface materials and floor coverings w ith low flame-spread characteristics — pipe insulation covers

Det Norske Veritas 0575 MED-B-9195 31 July 2014

X Expires: 29 October 2017

MED 1450227/ M1

Det Norske Veritas 0575 MED-B-9196 31 July 2014

X

Akron Brass Company, 343 Venture Blvd, P.O. Box 86, Wooster, OH 44691, United States of America (USA).

A.1/ 3.55 - Dual-purpose type nozzles (spray / jet type)

Lloyd’s Register Verification 0038 MED 1550060/ M2 18/ 01/ 2017

X Expires: 1 December 2019

MED 1650275/ M1

AkzoNobel Decorative Coatings B.V., Zevenakkersweg 4, 8191 AA WAPENVELD, Netherlands, The.

A.1/ 3.18(b) surface materials & floor coverings with low flame-spread characteristics (b): paint systems

Lloyd’s Register Verification 0038 MED 1550193 07/ 09/ 2015

X Expires: 4 October 2019

MED 1650244

Alarwool S.L., Calle Vitoria No. 15, 2 Piso, 09004 Burgos, Spain.

A.1/ 3.18(c) Surface materials and floor coverings with low flame-spread characteristics (floor coverings)

Lloyds Register Verification 0038 MED 1650278 24/ 09/ 2016

X Expires: 2 May 2018

MED 1500011/ M1

Page 394: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

394 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Andrew M uirhead & Son Limited, 273-289 Dunn Street, Glasgow, G40 3EA, United Kingdom (UK).

A.1/ 3.20 Upholstered furniture

Lloyd’s Register Verification 0038 MED 1050061/ M1 31-Jan-2013

X Expires: 5 January 2015

MED 1250003/ M3

ATIS International B.V., Noordhoek 33, 3351 LD Papendrecht, Netherlands, The.

A.1/3.13 Non-Combustible Material

Lloyd’s Register Verification 0038 MED 1350085/ M3 18 February 2015

X Expires: 7 December 2017

MED 1550049/ M3

Lloyd’s Register Verification 0038 MED 1450052/ M1 18 February 2015

X

Lloyd’s Register Verification 0038 MED 1450054/ M1 18 February 2015

X

Page 395: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

395 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

ATIS International B.V. ...continued

A.1/3.18(a) Surface materials and floor coverings w ith low flame-spread characteristics - (a) decorative veneers

Lloyd’s Register Verification 0038 MED 1550212 8 June 2015

X MED 1550049/ M3

Lloyd’s Register Verification 0038 MED 1550213 8 June 2015

X

Lloyd’s Register Verification 0038 MED 1750008/ M2 12 April 2017

X

Lloyd’s Register Verification 0038 MED 1350082/ M3 18 February 2015

X

Lloyd’s Register Verification 0038 MED 1350083/ M3 18 February 2015

X

Lloyd’s Register Verification 0038 MED 1350084/ M4 18 February 2015

X

BBM G Energy Saving M aterial & Technology Co. Ltd., No. 8 Xiaan Road, Dachang County, Hebei Province, China, People's Republic of.

A.1/ 3.11a “ A” & “ B” Class divisions fire integrity (a) “ A” class divisions

Lloyd’s Register Verification 0038 MED 1550144 Issued: 15-Jun-2015 MED 1550145 Issued: 15-Jun-2015

X X

Expires: 5 July 2018

MED 1550159

Page 396: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

396 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

BBM G Energy Saving M aterial & Technology Company, Gaojing #2, Chaoyang District, Beijing, 100123, China, People's Republic of.

A.1/ 3.11a 'A' AND 'B' Class Divisions Fire Integrity – (a) 'A' Class Divisions

Lloyds Register Verification 0038 MED 1550144 15/ 06/ 2016 MED 1550145 15/ 06/ 2016

X X

Expires: 29 June 2020

MED 1550155

Beijing New Building M aterials Company (BNBM ), De Wai Xisanqi, Beijing 100096, China, People's Republic of.

A.1/3.13 – Non-combustible materials

Lloyds Register Verification

0038 MED 0950343 Issue Date – 25 May 2009

X Expires: 11 July 2015

MED 1250116

Page 397: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

397 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Bentley Prince Street, 14641 E. Don Julian Rd, City of Industry, CA 91746, United States of America (USA).

A.1/ 3.18 Surface materials and floor coverings and low flame-spread characteristics (c) floor coverings

Lloyd’s Register Verification 0038 MED 1250097 29 May 2012 MED 1250098/ M1 14 June 2012 MED 1250099 29 May 2012 MED 1250100 29 May 2012

X Expires: 27 June 2015

MED 1250130

British Gypsum, Head Office, East Leake, Loughborough, Leicestershire, LE12 6HX, United Kingdom (UK).

A.1/ 3.13 Non-Combustible Materials

Lloyd's Register Verification 0038 MED 1450122 18/ 05/ 14

X Expires: 14 March 2015

MED 1200003/ M1

Bru Textiles, Satenrozen 2A, B-2550 Kontich, Belgium.

A.1/ 3.19 Draperies, curtains and other suspended textile materials and films

Lloyds Register Verification Ltd. 0038 MED 1050163/ M1 06-Sep-2010

X Expires: 9 August 2016

MED 1450001/ M1

Lloyds Register Verification Ltd. 0038 MED 1050164 07-Jul-2010

X

Lloyds Register Verification Ltd. 0038 MED 1050165 07-Jul-2010

X

Lloyds Register Verification Ltd. 0038 MED 1050340 19-Nov-2010

X

Lloyds Register Verification Ltd. 0038 MED 1050341 19-Nov-2010

X

Lloyds Register Verification Ltd. 0038 MED 1050166 07-Jul-2010

X

Page 398: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

398 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyds Register Verification Ltd. 0038 MED 1150303/ M1 28-Feb-2014

X

Lloyds Register Verification Ltd. 0038 MED 1150304 16-Nov-2011

X

Lloyds Register Verification Ltd. 0038 MED 1350086 24-Jun-2013

X

Lloyds Register Verification Ltd. 0038 MED 1350087 24-Jun-2013

X

Lloyds Register Verification Ltd. 0038 MED 1350088/ M1 03-Sep-2013

X

Page 399: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

399 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Bru Textiles ...continued A.1/ 3.20 Upholstered furniture

Lloyds Register Verification Ltd. 0038 MED 1050339 19-Nov-2010

X MED 1450001/ M1

Lloyds Register Verification Ltd. 0038 MED 1150302 16-Nov-2011

X

Captain Nemo, 7 Vasiladiou Street, 18540 Piraeus, Greece.

A.1/ 1.29 Embarkation ladders

Lloyds Register Verification Ltd 0038 MED 1350148 12 November 2013

X Expires: 20 November 2017

MED 1450248/ M1

A.1/ 4.49 Pilot ladder

Lloyds Register Verification Ltd 0038 MED 1350149 15 November 2013

X

Changzhou Bosin M echanical Co Ltd, Weicun, Xinbei District, Changzhou, Jiangsu, China, People's Republic of.

A.1/ 1.36 Lifeboat/ rescue boat propulsion engine

Lloyd’s Register Verification 0038 MED 1450164 24-Jun-2014

X Expires: 11 February 2020

MED 1750013

Chugoku M arine Paints (Shanghai), LTD., 4677, Jiasong Road (North), Jiading, Shanghai, China, People's Republic of.

A.1/ 3.18(b) Surface materials and floor coverings w ith low flame-spread characteristics (b) paint systems

Bureau Veritas 0062 23695/ B0 EC 09-May-2016

X Expires: 17 August 2017 MED 1450191/ M2

Bureau Veritas 0062 23696/ B0 EC 09-May-2016

X

Page 400: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

400 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Bureau Veritas 0062 15094/ C0 EC 09-Jul-2015

X

Bureau Veritas 0062 14011/ C1 EC 15-Dec-2015

X

Bureau Veritas 0575 15096/ C0 EC 08-Jul-2015

X

Bureau Veritas 0062 15097/ C0 EC 08-Jul-2015

X

Page 401: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

401 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Chugoku M arine Paints (Shanghai), LTD. ...continued

Bureau Veritas 0062 38713/ A0 EC 07-Jul-2014

X MED 1450191/ M2

A.1/ 3.18(c) Surface materials and floor coverings w ith low flame-spread characteristics (c) floor coverings

Bureau Veritas 0062 23764/ B0 EC 09-May-2016

X

Chugoku Paints B.V., Sluisweg 12, 4793 ZH Heijningen, Netherlands, The.

A.1/ 3.18(b) Surface Materials and Floors Coverings w ith Low Flame Spread Characteristics – Paint Systems

BV 0062 15094/ C0 EC 26/ 08/ 2015

X Expires: 13 December 2015

MED 1250235/ M1

BV 0062 14011/ C0/ EC 07/ 07/ 2014

X

Constructiewerkplaats H.K. van Wingerden & Zonen B.V., Industrieweg 18, 4214KZ Vuren, Netherlands, The.

A.1/ 3.25 “ A” and “ B” class fire-proof w indows and side scuttles

Lloyds Register 0038 MED 1050222 2 March 2010 MED 1250085 14 June 2012 MED 1250084 14 June 2012

X X X

Expires: 5 May 2019

MED 1650139

Page 402: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

402 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

MED 1450125 05 June 2014 MED 1550216 02 March 2015 MED 1350073 08 May 2013

X X X

MED 1450016 28 January 2014 MED 1450017 28 January 2014

X X

Page 403: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

403 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Crowcon Detection Instruments Ltd, 172 Brook Drive, M ilton Park, Abingdon, Oxfordshire, OX14 4SD, United Kingdom (UK).

A.1/3.30 Portable Oxygen Analysis & Gas Detection Equipment

Lloyd’s Register Verification 0038 MED 1000009/ M5 26 February 2015

X Expires: 31 May 2018

MED 1550134/ M1

Lloyd’s Register Verification 0038 MED 1000010/ M3 2 December 2014

X

Lloyd’s Register Verification 0038 MED 1000012/ M3 2 December 2014

X

Lloyd’s Register Verification 0038 MED 1000015/ M5 26 February 2015

X

Lloyd’s Register Verification 0038 MED 1000016/ M3 2 December 2014

X

Lloyd’s Register Verification 0038 MED 1000017/ M5 26 February 2015

X

Lloyd’s Register Verification 0038 MED 1000019/ M3 2 December 2014

X

Lloyd’s Register Verification 0038 MED 1000020/ M5 26 February 2015

X

Lloyd’s Register Verification 0038 MED 1500009/ M2 24/ 05/ 2016

X

Lloyd’s Register Verification 0038 MED 1600002 06/ 01/ 2016

X

Lloyd’s Register Verification 0038 MED 1600001/ M1 24/ 05/ 2016

X

Page 404: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

404 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Dafo Fomtec AB, Vindkraftsvagen 8, 13570 Stockholm, Sweden.

MED/ 3.58 – Fixed low expansion foam fire extinguishing systems components for machinery spaces and tanker deck protection.

Lloyd’s Register Verification 0038 MED 1250252/ M3 19 June 2014 MED 1250253/ M3 27 February 2014 MED 1450073 27 March 2014

X X X

Expires: 10 March 2019

MED 1650114/ M2

Page 405: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

405 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Dafo Fomtec AB ...continued

MED 1650134 21/ 04/ 2016 MED 1650135 21/ 04/ 2016

X X

MED 1650114/ M2

MED 1650199 26 July 2016

X

MED 1750024/ M1 21/ 03/ 2017

X

MED/ 3.59 Lloyd’s Register Verification 0038 MED 1650135 21/ 04/ 2016

X

Dalian M ingyang Deck Covering Co., Ltd., No. 468-8, Shuangdao Wan Road, Lvshunkou, Dalian, China, People's Republic of.

A.1/3.11(a) “ A” and “ B” Class divisions, fire integrity (a) “ A” class divisions

Lloyd’s Register Verification 0038 MED 1450114 And USCG Module B No: 164.105/ EC0038 17-Mar-2014

X Expires: 25 April 2016

MED 1350040/ M1

A.1/3.1 Primary Deck Coverings

Lloyd’s Register Verification 0038 MED 1650060 And USCG Module B No: 164.106/ EC0038 31-Oct-2015

X

Page 406: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

406 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1650061 And USCG Module B No: 164.106/ EC0038 31-Oct-2015

X

Lloyd’s Register Verification 0038 MED 1650062 And USCG Module B No: 164.106/ EC0038 31-Oct-2015

X

Page 407: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

407 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Dalian M ingyang Deck Covering Co., Ltd. ...continued

A.1/3.18(b) Surface materials and floor coverings w ith low flame-spread characteristics (b) paint systems

Lloyd’s Register Verification 0038 MED 1450157/ M1 And USCG Module B No: 164.112/ EC0038 17-Mar-2014

X MED 1350040/ M1

Daniamant ApS, Industrivej 24C, DK-3550 Slangerup, Denmark.

MED/ 1.2 0168 X Expires: 2 November 2019

MED 1750062/ M2

0168 BABT-MED000040 Issue 2 29/ 04/ 2014

X

0168 BABT-MED000041 Issue 1 17/ 12/ 2012

X

0168 BABT-MED000042 Issue 2 19/ 08/ 2015

X

0168 BABT-MED000055 Issue 3 12/ 11/ 2014

X

0168 BABT-MED000071 Issue 1 29/ 04/ 2015

X

0168 BABT-MED000096 Issue 1 04/ 04/ 2016

X

Page 408: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

408 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

0168 BABT-MED000097 Issue 1 04/ 04/ 2016

X

0168 BABT-MED001093 Issue 2 11/ 11/ 2013

X

0168 BABT-MED001094 Issue 2 20/ 03/ 2013

X

0168 BABT-MED001095 Issue 2 20/ 01/ 2014

X

Page 409: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

409 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Daniamant ApS ...continued 0168 BABT-MED001096 Issue 2 23/ 12/ 2013

X MED 1750062/ M2

0168 BABT-MED001097 Issue 2 15/ 03/ 2016

X

0168 BABT-MED001100 Issue 1 21/ 01/ 2013

X

0168 BABT-MED001101 Issue 2 31/ 07/ 2014

X

0168 BABT-MED001102 Issue 2 31/ 07/ 2014

X

0168 BABT-MED001103 Issue 2 08/ 10/ 2014

X

0168 BABT-MED001104 Issue 2 08/ 10/ 2014

X

0168 BABT-MED001105 Issue 2 04/ 08/ 2016

X

0168 BABT-MED001106 Issue 2 19/ 08/ 2015

X

0168 BABT-MED001107 Issue 2 01/ 06/ 2015

X

Page 410: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

410 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

0168 BABT-MED001111 Issue 2 21/ 11/ 2013

X

0168 BABT-MED001113 Issue 5 02/ 03/ 2016

X

0168 BABT-MED001118 Issue 3 05/ 01/ 2016

X

0168 BABT-MED001112 Issue 5 02/ 03/ 2016

X

Page 411: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

411 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Daniamant ApS ...continued Lloyd’s Register 0038 MED 1650264 03/ 11/ 2016

X MED 1750062/ M2

Lloyd’s Register 0038 MED 1650280 21/ 11/ 2016

X

Lloyd’s Register 0038 MED 1650281 22/ 11/ 2016

X

Lloyd’s Register 0038 MED 1650282 22/ 11/ 2016

X

Lloyd’s Register 0038 MED 1750059 27/ 03/ 2017

X

Lloyd’s Register 0038 MED 1750055 24/ 03/ 2017

X

Lloyd’s Register 0038 MED 1750058 27/ 03/ 2017

X

Daniamant Limited, Unit 3,The Admiral Park, Airport Service Road, Hilsea, Portsmouth, Hampshire, PO3 5RQ, United Kingdom (UK).

A.1/ 1.2 Position-Indicating Lights for life saving appliances (a) for survival craft and rescue boats (b) for Lifebuoys (c) for Lifejackets

Lloyds Register Verification 0038 MED 1650264 03/ 11/ 2016

X Expires: 2 November 2019

MED 1650265/ M2

Lloyds Register Verification 0038 MED 1650280 21/ 11/ 2016

X

Lloyds Register Verification 0038 MED 1650281 22/ 11/ 2016

X

Lloyds Register Verification 0038 MED 1650282 22/ 11/ 2016

X

Lloyds Register Verification 0038 MED 1750055 24/ 03/ 2017

X

Lloyds Register Verification 0038 MED 1750058 27/ 03/ 2017

X

Page 412: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

412 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyds Register Verification 0038 MED 1750059 27/ 03/ 2017

X

BABT 0168 BABT-MED001093 11/ 11/ 2013

X

BABT 0168 BABT-MED001094 20/ 03/ 2013

X

BABT 0168 BABT-MED000040 29/ 04/ 2014

X

BABT 0168 BABT-MED000041 17/ 12/ 2012

X

Page 413: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

413 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Daniamant Limited ...continued

BABT 0168 BABT-MED000042 19/ 08/ 2015

X MED 1650265/ M2

BABT 0168 BABT-MED001100 21/ 01/ 2013

X

BABT 0168 BABT-MED001101 31/ 07/ 2014

X

BABT 0168 BABT-MED001102 31/ 07/ 2014

X

BABT 0168 BABT-MED001103 08/ 10/ 2014

X

BABT 0168 BABT-MED001104 08/ 10/ 2014

X

BABT 0168 BABT-MED000055 12/ 11/ 2014

X

BABT 0168 BABT-MED001105 04/ 08/ 2016

X

BABT 0168 BABT-MED001106 19/ 08/ 2015

X

BABT 0168 BABT-MED001111 21/ 11/ 2013

X

BABT 0168 BABT-MED0000095 19/ 12/ 2016

X

Page 414: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

414 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Daoming Optics & Chemicals Co.,Ltd, No. 001 Yingbin Road, 3rd Xiangzhu Industrial Zone,, Yongkang, Zhejiang Province, 321313, China, People's Republic of.

A.1/ 1.30 – Retro-Reflective Material

Lloyds Register Verification 0038 MED 1550248/ M1 17/ 09/ 2016

X Expires: 12 April 2019

MED 1650122/ M1

Deerberg Systems, M oltkestraße 6a, 26122 Oldenburg, Germany.

A.1/ 2.7 Shipboard Incinerators

Lloyd’s Register Verification 0038 MED 1500018 16/ 02/ 2015

X Expires: 15 July 2018

MED 1550227/ M2

Lloyd’s Register Verification 0038 MED 1600004/ M1 20/ 09/ 2015

X

Lloyd’s Register Verification 0038 MED 1600005/ M1 08/ 09/ 2015

X

Lloyd’s Register Verification 0038 MED 1650092 09/ 03/ 2016

X

Page 415: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

415 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Deerberg Systems ...continued

Lloyd’s Register Verification 0038 MED 1600009 25/ 05/ 2016

X MED 1550227/ M2

Delta Fire Limited, Wendover Road, Rackheath Industrial Estate, Norwich, NR13 6LH, United Kingdom (UK).

A.1/ 3.55 – Dual-Purpose Type Nozzles (spray Jet / Jet Type)

Lloyd Register Verification 0038 MED 1650232 24.09.2016

X Expires: 27 September 2019

MED 1650246

Desso B.V., Taxandriaweg 15, 5142 PA Waalwijk, Netherlands, The.

A.1/3.18 Surface Materials & Floor Coverings With Low Flame-Spread Characteristics (c): Floor Coverings

Lloyd’s Register Verification 0038 MED 1350041 And USCG Module B No: 164.117/ EC0038 22 March 2013

X Expires: 1 April 2020

MED 1550072

Lloyd’s Register Verification 0038 MED 1450172 And USCG Module B No: 164.117/ EC0038 02 Sep 2014

X

Lloyd’s Register Verification 0038 MED 1450174 And USCG Module B No: 164.117/ EC0038 02 Sep 2014

X

Page 416: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

416 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1450176 And USCG Module B No: 164.117/ EC0038 02 Sep 2014

X

Dong Bang Electronic Industrial Co. Ltd., 138-4 Sangdaewon-Dong, Jungwon-Gu, Sungnam-Shi Gyeonggi-do, Korea, Republic of.

A.1/ 3.45 – Equivalent fixed gas fire extinguishing systems components for machinery spaces and cargo pump rooms

Lloyd’s Register Verification 0038 MED 1150157 02-Jan-2011

X Expires: 3 September 2015

MED 1250156

DONIM ET Spolka z ograniczona odpowiedzialnoscia Sp.K, 05-660 Warka, ul. Gosniewska 43, Poland.

A.1/ 3.16 – FIRE DOORS Lloyd’s Register Verification 0038 MED 1450186 08-Sept-2014

X Expires: 9 February 2018

MED 1550067

Page 417: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

417 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

DONIM ET Spolka z ograniczona odpowiedzialnoscia Sp.K ...continued

Lloyd’s Register Verification 0038 MED 1550246 03.11.2015

X MED 1550067

Draeger Safety (UK) Limited, Ullswater Close, Blyth, Northumberland, NE24 4RG, United Kingdom (UK).

A.1/ 3.7 Self-contained compressed-air-operated breathing apparatus

Lloyd’s Register Verification 0038 MED 1450029 13-Feb-2014

X Expires: 19 January 2020

MED 1650291

Lloyd’s Register Verification 0038 MED 1450030/ M1 22-Jul-2015

X

Lloyd’s Register Verification 0038 MED 1450031 13-Feb-2014

X

A.1/ 3.41 Emergency escape breathing devices (EEBD)

Lloyd’s Register Verification 0038 MED 1450032 13-Feb-2014

X

Lloyd’s Register Verification 0038 MED 1450033/ M1 27/ 09/ 2016

X

Drew M arine Signal & Safety Spain SL, Camino M endi S/N, Esquiroz de Galar, Navarra, 31191, Spain.

A.1/1.9 Lloyd’s Register Verification 0038 MED 1650088 23.01.2016

X Expires: 10 May 2019

MED 1650137

A.1/ 1.10 Lloyd’s Register Verification 0038 MED 1650089 23.01.2016

X

A.1/1.8 Lloyd’s Register Verification 0038 MED 1650090 05.01.2016

X

Page 418: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

418 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

A.1/ 1.9 Lloyd’s Register Verification 0038 MED 1250004/ M1 17.12.2012

X

Durastic Ltd., Unit 47, Cuthbert Court, Bede Industrial Estate, Jarrow, Tyne & Wear, NE32 3HG, United Kingdom (UK).

A.1/ 3.1 Primary Deck Coverings

Lloyd’s Register Verification 0038 MED 1450240/ M1 21/ 07/ 2016

X Expires: 4 March 2019

MED 1650123

Lloyd’s Register Verification 0038 MED 1550162 01/ 08/ 2015

X

Page 419: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

419 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Durastic Ltd. ...continued Lloyd’s Register Verification 0038 MED 1250248 18/ 11/ 2012

X MED 1650123

Lloyd’s Register Verification 0038 MED 1250249 18/ 11/ 2012

X

A.1/ 3.11(a) “ A” and “ B” Class divisions, fire integrity (a) “ A” class divisions

Lloyd’s Register Verification 0038 MED 1250250/ M1 1250250/ M1

X

EGGER KUNSTSTOFFE GmbH & Co. KG, Im Weilandmoor 2, D-38518 Gifhorn, Germany.

A.1/ 3.18(a) Fire Resisting Material

Lloyd’s Register Verification 0038 MED 1350124 24-Sep-2013

X Expires: 13 October 2016

MED 1350140

A.1/ 3.18 - A.1/ 3.18 Surface materials and floor coverings with low flame spread characteristics (a) decorative veneers

Lloyds Register Verification 0038 MED 135124/ M1 14/ 03/ 2017

X Expires: 7 September 2019

MED 1650220/ M2

Environmental Protection Engineering S.A., 24 Dervenakion Street, 185 45 Piraeus, Greece.

A.1/ 2.6 Sewage Systems

Lloyd’s Register Verification 0038 MED 1550272 03.12.2015

X Expires: 31 January 2018

MED 1550064/ M3

MED 1550270 03.12.2015

X

MED 1550265 03.12.2015

X

MED 1550273 03.12.2015

X

Page 420: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

420 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

MED 1550274 03.12.2015

X

MED 1550271 03.12.2015

X

MED 1550267 03.12.2015

X

MED 1550269 03.12.2015

X

MED 1550268 03.12.2015

X

MED 1550266 03.12.2015

X

Page 421: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

421 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Environmental Protection Engineering S.A. ...continued

MED 1650024 19.01.2016

X MED 1550064/ M3

MED 1650025 19.01.2016

X

MED 1650026 19.01.2016

X

MED 1650027 19.01.2016

X

MED 1650028 19.01.2016

X

MED 1650029 19.01.2016

X

MED 1650030 19.01.2016

X

MED 1650031 19.01.2016

X

MED 1650032 19.01.2016

X

MED 1650033 19.01.2016

X

A.1/ 2.1 Oil-filtering equipment (for an oil content of the effluent not exceeding 15 p.p.m.)

Lloyd’s Register Verification 0038 MED 1350138 25.10.2013

X

MED 1550084 17.04.2015

X

MED 1550104 17.04.2015

X

MED 1550105 17.04.2015

X

Page 422: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

422 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

MED 1550106 17.04.2015

X

MED 1550107 17.04.2015

X

MED 1550108 17.04.2015

X

MED 1550109 17.04.2015

X

MED 1550110 17.04.2015

X

MED 1650174 02.06.2016

X

Page 423: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

423 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Environmental Protection Engineering S.A. ...continued

MED 1650175 02.06.2016

X MED 1550064/ M3

MED 1650176 02.06.2016

X

MED 1650177 02.06.2016

X

MED 1650178 02.06.2016

X

Evac Oy, Sinimäentie 14, FIN-02630 Espoo, Finland.

A.1/ 2.6 – Sewage Systems Lloyd’s Register Verification 0038 MED 1650004 08/ 11/ 2015 MED 1650005 08/ 11/ 2015 MED 1650006

X X X

Expires: 29 July 2018

MED 1550179/ M1

08/ 11/ 2015 MED 1650008 08/ 11/ 2016 MED 1650009 08/ 11/ 2015

X X

Page 424: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

424 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

MED 1650010 08/ 11/ 2015 MED 1550008 09/ 01/ 2015 MED 1550061 18/ 03/ 2015

X X X

Eversafe Extinguisher Sdn Bhd, Lot 878, Jalan Subang 9, Taman Perindustrian Subang, 47500 Subang Jaya, Selangor Darul Ehsan, M alaysia.

A.1/3.2 – Portable Fire Extinguishers

Lloyd’s Register Verification 0038 MED 1050152 28-Jun-2010

X Expires: 15 April 2015

MED 1250064

Lloyd’s Register Verification 0038 MED 1050153 28-Jun-2010

X

Page 425: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

425 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Eversafe Extinguisher Sdn Bhd ...continued

Lloyd’s Register Verification 0038 MED 1050211 20-Aug-2010

X MED 1250064

Lloyd’s Register Verification 0038 MED 1050282 12-Oct-2010

X

Lloyd’s Register Verification 0038 MED 1050283 12-Oct-2010

X

Lloyd’s Register Verification 0038 MED 1050284 12-Oct-2010

X

Lloyd’s Register Verification 0038 MED 1050285 12-Oct-2010

X

A.1/3.52 – Non-portable and transportable fire extinguishers

Lloyd’s Register Verification 0038 MED 1050103 06-May-2010

X

Lloyd’s Register Verification 0038 MED 1050104 06-May-2010

X

Lloyd’s Register Verification 0038 MED 1050105 06-May-2010

X

Lloyd’s Register Verification 0038 MED 1050106 06-May-2010

X

Lloyd’s Register Verification 0038 MED 1050107 06-May-2010

X

Lloyd’s Register Verification 0038 MED 1050152 28-Jun-2010

X

Lloyd’s Register Verification 0038 MED 1050153 28-Jun-2010

X

Lloyd’s Register Verification 0038 MED 1050211 20-Aug-2010

X

Lloyd’s Register Verification 0038 MED 1050282 12-Oct-2010

X

Lloyd’s Register Verification 0038 MED 1050283 12-Oct-2010

X

Page 426: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

426 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1050284 12-Oct-2010

X

Lloyd’s Register Verification 0038 MED 1050285 12-Oct-2010

X

Fabryka M ebli Okretowych FAM OS Sp z.o.o, ul Gdanska 37, 83-200 Starogard, Gdanski, Poland.

A.1/ 3.11b - “ A” and “ B” class divisions fire integrity (b) “ B” class divisions

Lloyds Register Verification 0038 MED 1150317 05/ 12/ 2011

X Expires: 22 March 2018

MED 1650102/ M1

Lloyds Register Verification 0038 MED 1250020 18/ 03/ 2012

X

Page 427: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

427 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fabryka M ebli Okretowych FAM OS Sp z.o.o ...continued

Lloyds Register Verification 0038 MED 1250021 25/ 04/ 2012

X MED 1650102/ M1

Lloyds Register Verification 0038 MED 1250025 01/ 03/ 2012

X

Lloyds Register Verification 0038 MED 1250107 03/ 07/ 2012

X

Lloyds Register Verification 0038 MED 1250111 19/ 10/ 2012

X

Lloyds Register Verification 0038 MED 1250112 19/ 10/ 2012

X

Lloyds Register Verification 0038 MED 1250184 19/ 10/ 2012

X

Lloyds Register Verification 0038 MED 1350098 28/ 07/ 2013

X

Lloyds Register Verification 0038 MED 1350129 17/ 10/ 2013

X

Lloyds Register Verification 0038 MED 1350136 04/ 12/ 2013

X

CTO S.A 2434 NC/ MED/ 032 15/ 05/ 2016

X

CTO S.A 2434 NC/ MED/ 029 28/ 03/ 2016

X

CTO S.A 2434 NC/ MED/ 025 03/ 03/ 2016

X

CTO S.A 2434 NC/ MED/ 026 30/ 05/ 2016

X

CTO S.A 2434 NC/ MED/ 027 14/ 03/ 2016

X

Page 428: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

428 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyds Register Verification 0038 NC/ MED/ 036 26/ 06/ 2016

X

Lloyds Register Verification 0038 NC/ MED/ 030 28/ 03/ 2016

X

Lloyds Register Verification 0038 MED 1350137 04/ 12/ 2013

X

CTO S.A 2434 NC/ MED/ 001 26/ 09/ 2013

X

Page 429: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

429 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fabryka M ebli Okretowych FAM OS Sp z.o.o ...continued

CTO S.A 2434 NC/ MED/ 002 17/ 12/ 2013

X MED 1650102/ M1

CTO S.A 2434 NC/ MED/ 004 07/ 03/ 2014

X

CTO S.A 2434 NC/ MED/ 010 01/ 04/ 2014

X

CTO S.A 2434 NC/ MED/ 011 01/ 04/ 2014

X

A.1/ 3.11 – “ A” and “ B” class divisions fire integrity (b) “ B” class divisions

CTO S.A 2434 NC/ MED/ 014 10/ 11/ 2014

X

CTO S.A 2434 NC/ MED/ 017 11/ 08/ 2015

X

CTO S.A 2434 NC/ MED/ 018 26/ 08/ 2015

X

CTO S.A 2434 NC/ MED/ 019 11/ 08/ 2015

X

CTO S.A 2434 NC/ MED/ 024 12/ 02/ 2016

X

A.1/ 3.16 – Fire Doors CTO S.A 2434 MED 1150142 15/ 05/ 2011

X

CTO S.A 2434 MED 1250019 18/ 03/ 2012

X

CTO S.A 2434 MED 1250075 27/ 06/ 2012

X

CTO S.A 2434 NC/ MED/ 003 05/ 02/ 2014

X

CTO S.A 2434 NC/ MED/ 012 15/ 09/ 2014

X

Page 430: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

430 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

CTO S.A 2434 NC/ MED/ 013 07/ 10/ 2014

X

A.1/ 3.16 – Fire Doors CTO S.A 2434 NC/ MED/ 015 25/ 03/ 2015

X

CTO S.A 2434 MC/ MED/ 016 19/ 03/ 2015

X

CTO S.A 2434 NC/ MED/ 020 11/ 08/ 2015

X

CTO S.A 2434 NC/ MED/ 021 15/ 01/ 2015

X

CTO S.A 2434 NC/ MED/ 033

X

Page 431: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

431 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Fabryka M ebli Okretowych FAM OS Sp z.o.o ...continued

A.1/ 3.64 – “ C” class divisions CTO S.A 2434 NC/ MED/ 005 13/ 03/ 2014

X MED 1650102/ M1

CTO S.A 2434 NC/ MED/ 006 13/ 03/ 2014

X

CTO S.A 2434 NC/ MED/ 007 13/ 03/ 2014

X

CTO S.A 2434 NC/ MED/ 008 13/ 03/ 2014

X

CTO S.A 2434 NC/ MED/ 009 13/ 03/ 2014

X

CTO S.A 2434 NC/ MED/ 028 11/ 03/ 2016

X

CTO S.A 2434 NC/ MED/ 034 03/ 06/ 2016

X

CTO S.A 2434 NC/ MED/ 035 03/ 06/ 2016

X

Familon Oy, Heikkilantie 7B, FI -00210, Helsinki, Finland.

A.1/ 3.21 Bedding components

VTT Building Technology 0809 VTT-C-11521-15-16 25/ 01/ 2016

X Expires: 17 June 2019

MED 1650162/ M2

VTT Building Technology 0809 VTT-C-11803-15-16 14/ 11/ 2016

X

VTT Building Technology 0809 VTT-C-11907-15-17 20/ 01/ 2017

X

VTT Building Technology 0809 VTT-C-11905-15-17 20/ 01/ 2017

X

VTT Building Technology 0809 VTT-C-11909-15-17 20/ 01/ 2017

X

Page 432: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

432 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

VTT Building Technology 0809 VTT-C-11906-15-17 20/ 01/ 2017

X

VTT Building Technology 0809 VTT-C-11908-15-17 20/ 01/ 2017

X

VTT-C-11526-15-16 25/ 01/ 2016

X

VTT-C-11527-15-16 25/ 01/ 2016

X

Page 433: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

433 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

FCD Systems Limited, Causeway House, 1 Dane Street, Bishop's Stortford, Hertfordshire, United Kingdom (UK).

A.1/ 3.22 0038 164.139/EC0038/ MED 1250024/ M2

MED 1250024/ M2 15 March 2013

x Expires: 21 March 2016

MED 1350046/ M1

Firecon Group Oy, Otto Korhosen katu 1, 20660 Littoinen, Finland.

A.1/ 3.9 Sprinkler systems components for accommodation spaces, service spaces and control stations equivalent to that referred to in SOLAS 74 Reg. I I -2/12 (Limited to nozzles and their performance)

Lloyd’s Register Verification 0038 MED 1150181/ M2 25-October-2013

X Expires: 18 June 2017

MED 1450141

Fixed water-based local application fire-fighting systems components for use in category “A” machinery spaces (Nozzles and performance tests)

Lloyd’s Register Verification 0038 MED 1150182/ M2 25-October-2013

X

Fritz Egger GmbH & Co. OG, Weiberndorf 20, A-6380 St. Johann in Tirol, Austria.

A.1/ 3.18 – Surface Materials and floor coverings with low flame spread characteristics (a) decorative veneers

Llyods Register Verification 0038 MED 1650116 08.04.2016

X Expires: 24 May 2019

MED 1650154

GAS M EASUREM ENT INSTRUM ENTS LTD, Inchinnan Business Park, Renfrew, Scotland, PA4 9RG, United Kingdom (UK).

A.1/ 3.30 Portable oxygen Analysis & Gas Detection Equipment

Lloyd’s Register Verification 0038 MED 160010 07/ 06/ 2016

X Expires: 8 June 2018

MED 1500006/ M2

Page 434: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

434 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1300015/ M3 14-Dec-2014

X

Lloyd’s Register Verification 0038 MED 1200009/ M5 09-Feb-2015

X

Lloyd’s Register Verification 0038 MED 0900002/ M4 10-Dec-2014

X

A.1/ 3.54 Fixed Oxygen Analysis & Gas Detection Equipment

Lloyd’s Register Verification 0038 MED 1500008 10-Jun-2015

X

Page 435: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

435 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Haihua Electronics Enterprise (China) Corporation, 163 Pingyun Road, West of Huangpu Avenue, Guangzhou 510656, China, People's Republic of.

A.1/ 4.30 Electronic Chart Display & Information System ECDIS with Backup, and raster chart display (RCDS)

Lloyd’s Register Verification 0038 MED 1200004 11-Apr-2012

X Expires: 2 March 2018

MED 1550070/ M1

Halo Imaging Ltd., Gadwall Road, Rainton Bridge South Business Park, Houghton-Le-Spring, Tyne and Wear, DH4 5NL, United Kingdom (UK).

A.1/3.6 Fire Fighter’s Outfit: Helmet

Lloyd’s Register Verification 0038 MED 1650279/ M3 16/ 02/ 2017

X Expires: 29 May 2019

MED 1650136/ M2

HawkeTransitSystemSL, P.ETanosViernolesparcelaC9C10, 39300 Torrelavega (Santander), Spain.

A.1/ 3.26 Penetrations through “A” class divisions (a) electric cable transits (b) pipe, duct, trunk, etc. penetrations

Lloyd’s Register Verification 0038 MED 1650157/ M1 03/ 08/ 2016

X Expires: 14 July 2017

MED 1450148/ M3

Lloyd’s Register Verification 0038 MED 1550126/ M3 03/ 08/ 2016

X

Lloyd’s Register Verification 0038 MED 1550011/ M3 03/ 08/ 2016

X

Lloyd’s Register Verification 0038 MED 1550010/ M2 27/ 05/ 2016 USCG NO. 164.138/ EC0038

X

Page 436: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

436 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1550003/ M2 27/ 05/ 2016 USCG NO. 164.138/ EC0038

X

Lloyd’s Register Verification 0038 MED 1550004/ M2 27/ 05/ 2016 USCG NO. 164.138/ EC0038

X

Page 437: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

437 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Hefei Xingtu Reflective M aterial Co., Ltd, Longtong Industrial Park, Cuozhen Town, Feigong County, Hefei City, Anhui Province, 231602, China, People's Republic of.

A.1/ 1.30 Retro-Reflective Materials

Lloyds Register Verification 0038 MED 1550223 21.09.2015

X Expires: 13 October 2019

MED 1650260

Hempel (USA) Inc., 600 Conroe Park North Drive, Conroe, Texas, United States of America (USA).

A.1/ 3.18b Surface Materials & Floor Coverings with low flame-spread characteristics (b) paint systems

Lloyds Register Verification Ltd. 0038 MED-B-9177 04-Aug-2014

X Expires: 14 February 2016

MED 1350013/ M1

Lloyds Register Verification Ltd. 0038 MED-B-9178 04-Aug-2014

X

Lloyds Register Verification Ltd. 0038 MED-B-9179 04-Aug-2014

X

Lloyds Register Verification Ltd. 0038 MED-B-9180 04-Aug-2014

X

Lloyds Register Verification Ltd. 0038 MED-B-8837 05-Mar-2014

X

Lloyds Register Verification Ltd. 0038 MED-B-8838 05-Mar-2014

X

Lloyds Register Verification Ltd. 0038 MED-B-8839 05-Mar-2014

X

Lloyds Register Verification Ltd. 0038 MED-B-9176 04-Aug-2014

X

Page 438: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

438 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyds Register Verification Ltd. 0038 MED-B-6495 05-Oct-2010

X

Lloyds Register Verification Ltd. 0038 MED-B-6496 05-Oct-2010

X

HLB CO., Ltd., 272-12, Dangwol-ro, Onsan-Eup, Ulju-Gun, Ulsan, 689-892, Korea, Republic of.

MED/ 1.17 – Lifeboats: (a) Davit-Launched Lifeboats

Lloyds Register Verification Ltd. 0038 MED 1250225 05/ 11/ 2012

X Expires: 31 March 2020

MED 1750082

Lloyds Register Verification Ltd. 0038 MED 1250226 05/ 11/ 2012

X

Page 439: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

439 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

HLB CO., Ltd. ...continued Lloyds Register Verification Ltd. 0038 MED 1350071 31/ 05/ 2013

X MED 1750082

Lloyds Register Verification Ltd. 0038 MED 1250228 02/ 11/ 2012

X

Lloyds Register Verification Ltd. 0038 MED 1650119 07/ 03/ 2016

X

Lloyds Register Verification Ltd. 0038 MED 1650120 07/ 03/ 2016

X

Lloyds Register Verification Ltd. 0038 MED 1350072 31/ 05/ 2013

X

Lloyds Register Verification Ltd. 0038 MED 1250227 05/ 11/ 2012

X

Lloyds Register Verification Ltd. 0038 MED 1450046/ M1 10/ 03/ 2014

X

Lloyds Register Verification Ltd. 0038 MED 1550185 26/ 03/ 2015

X

Lloyds Register Verification Ltd. 0038 MED 1350089 24/ 06/ 2013

X

Lloyds Register Verification Ltd. 0038 MED 1350075 31/ 05/ 2013

X

Lloyds Register Verification Ltd. 0038 MED 1550184 26/ 03/ 2015

X

Lloyds Register Verification Ltd. 0038 MED 1450047/ M1 10/ 03/ 2014

X

Lloyds Register Verification Ltd. 0038 MED 1350074 31/ 05/ 2013

X

2198 MED-MB-1026-14 05/ 03/ 2014

X

2198 MED-MB-1238-15 10/ 11/ 2015

X

Page 440: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

440 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

MED/ 1.18 – Rigid Rescue Boats Lloyds Register Verification Ltd. 0038 MED 1250093/ M2 17/ 06/ 2013

X

Lloyds Register Verification Ltd. 0038 MED 1450046/ M1 10/ 03/ 2014

X

Lloyds Register Verification Ltd. 0038 MED 1250228 02/ 11/ 2012

X

Lloyds Register Verification Ltd. 0038 MED 1350074 31/ 05/ 2013

X

Lloyds Register Verification Ltd. 0038 MED 1450047/ M1 10/ 03/ 2014

X

Lloyds Register Verification Ltd. 0038 MED 1350075 31/ 05/ 2013

X

Page 441: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

441 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

HLB CO., Ltd. ...continued Lloyds Register Verification Ltd. 0038 MED 1350071 31/ 05/ 2013

X MED 1750082

Lloyds Register Verification Ltd. 0038 MED 1350072 31/ 05/ 2013

X

Lloyds Register Verification Ltd. 0038 MED 1250227 05/ 11/ 2012

X

Lloyds Register Verification Ltd. 0038 MED 1250226 05/ 11/ 2012

X

Lloyds Register Verification Ltd. 0038 MED 1250225 05/ 11/ 2012

X

2198 13-BK1028621-EC 25/ 03/ 2013

X

2198 MED-MB-1026-14 05/ 03/ 2014

X

2198 MED-MB-1205-13 23/ 09/ 2013

X

2198 MED-MB-1238-15 10/ 11/ 2015

X

MED/ 1.20 – Fast Rescue Boats Lloyds Register Verification Ltd. 0038 MED 1550207 13/ 08/ 2015

X

MED/ 1.26 – Release mechanism for (a) lifeboat and rescue boats (Launched by fall or falls)

Lloyds Register Verification Ltd. 0038 MED 1250146/ M1 25/ 03/ 2014

X

Lloyds Register Verification Ltd. 0038 MED 1650251 17/ 09/ 2016

X

Lloyds Register Verification Ltd. 0038 MED 1250153/ M1 25/ 03/ 2014

X

MED/ 1.36 – Lifeboat/ rescue boat propulsion engine

Lloyds Register Verification Ltd. 0038 MED 1350004 17/ 01/ 2013

X

Lloyds Register Verification Ltd. 0038 MED 1350128 09/ 10/ 2013

X

Page 442: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

442 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyds Register Verification Ltd. 0038 MED 1550188 17/ 05/ 2017

X

Lloyds Register Verification Ltd. 0038 MED 1550187 17/ 05/ 2015

x

Imtech Deutschland GmbH & Co. KG Schiffbau-/Dockbautechnik, Hammer Straße 32, D-22041 Hamburg, Germany.

M ED/3.48 Fixed water based local application fire fighting systems components for use in category .A. machinery spaces

Lloyd’s Register Verification 0038 MED 1750010 07/ 02/ 2017

X Expires: 24 September 2018

MED 1650130/ M1

Page 443: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

443 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint (Korea) Ltd., 17 Gongdandong-gil, Chilsea-myeon, Haman-gun, Gyeongsangnam-do, Korea, Republic of.

MED/ 3.18b – Surface Materials & Floor Coverings w ith Flame-Spread Characteristics – Paint System

Lloyds Register Verification Ltd. 0038 MED 1450059/ M2 14/ 09/ 2016

X Expires: 5 April 2020

MED 1750064

MED 1450058/ M2 14/ 09/ 2016

X

MED 1350165 13/ 12/ 2013

X

MED 1450063/ M2 14/ 12/ 2016

X

MED 1650210/ M1 13/ 09/ 2016

X

MED 1350169 12/ 12/ 2018

X

MED 1550277 19/ 01/ 2016

X

MED 1450060 23/ 02/ 2014

X

MED 1650180 11/ 07/ 2016

X

MED 1550102/ M2 13/ 09/ 2016

X

MED 1650234 14/ 12/ 2016

X

MED 1550117 29/ 04/ 2015

X

MED 1650235 14/ 12/ 2016

X

Page 444: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

444 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

MED 1350170 13/ 12/ 2013

X

MED 1650236 14/ 12/ 2016

X

MED 1250199 18/ 10/ 2012

X

MED 1550211/ M1 09/ 09/ 2015

X

MED 1350168 13/ 12/ 2013

X

Page 445: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

445 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint (Korea) Ltd. ...continued

MED 1550209/ M1 07/ 09/ 2015

X MED 1750064

MED 1550210/ M1 03/ 09/ 2015

X

MED 1550249/ M1 13/ 09/ 2016

X

MED 1350052 01/ 05/ 2013

X

MED 1350037 19/ 03/ 2013

X

MED 1650181 11/ 07/ 2016

X

MED 1550116 29/ 04/ 2015

X

MED 1350167 13/ 12/ 2013

X

MED 1350051 01/ 05/ 2013

X

MED 1650014 19/ 01/ 2016

X

MED 1350166 13/ 12/ 2013

X

International Paint Ltd, Stoneygate Lane, Felling, Gateshead, Tyne & Wear, NE10 0JY, United Kingdom (UK).

A.1/ 3.18 Surface materials and floor coverings with low flame-spread characteristics (b) paint systems

Lloyds Register Verification Ltd. 0038 MED 1550198 07.08.2015

X Expires: 20 December 2017

MED 1550001/ M3

Lloyds Register Verification Ltd. 0038 MED 1250158 04.09.2012

X

Page 446: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

446 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyds Register Verification Ltd. 0038 MED 1250159 06.09.2012

X

Lloyds Register Verification Ltd. 0038 MED 1350012 12.02.2012

X

Lloyds Register Verification Ltd. 0038 MED 1450049 06.03.2014

X

Lloyds Register Verification Ltd. 0038 MED 1450050 06.03.2014

X

Lloyds Register Verification Ltd. 0038 MED 1450086 07.04.2014

X

Lloyds Register Verification Ltd. 0038 MED 1450088 07.04.2014

X

Page 447: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

447 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Lloyds Register Verification Ltd. 0038 MED 1450090 08.04.2014

X MED 1550001/ M3

Lloyds Register Verification Ltd. 0038 MED 1450091 08.04.2014

X

Lloyds Register Verification Ltd. 0038 MED 1450093 08.04.2014

X

Lloyds Register Verification Ltd. 0038 MED 1450099 09.06.2014

X

Lloyds Register Verification Ltd. 0038 MED 1450103 09.06.2014

X

Lloyds Register Verification Ltd. 0038 MED 1450109 09.06.2014

X

Lloyds Register Verification Ltd. 0038 MED 1450110 09.06.2014

X

Lloyds Register Verification Ltd. 0038 MED 1450162/ M1 14.09.2016

X

Lloyds Register Verification Ltd. 0038 MED 1450163/ M1 14.09.2016

X

Lloyds Register Verification Ltd. 0038 MED 1450202/ M1 14.09.2016

X

Lloyds Register Verification Ltd. 0038 MED 155079/ M1 14.09.2016

X

Lloyds Register Verification Ltd. 0038 MED 1550090/ M1 14.09.2016

X

Lloyds Register Verification Ltd. 0038 MED 1550091/ M1 14.09.2016

X

Lloyds Register Verification Ltd. 0038 MED 1550092/ M1 14.09.2016

X

Lloyds Register Verification Ltd. 0038 MED 1550093 25.04.2015

X

Page 448: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

448 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyds Register Verification Ltd. 0038 MED 1550094/ M1 13.09.2016

X

Lloyds Register Verification Ltd. 0038 MED 1550138 04.06.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550168 27.08.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550169 27.08.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550170 27.08.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550171 27.08.2015

X

Page 449: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

449 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Lloyds Register Verification Ltd. 0038 MED 1550172 27.08.2015

X MED 1550001/ M3

Lloyds Register Verification Ltd. 0038 MED 1550173 27.08.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550174 27/ 08/ 2015

X

Lloyds Register Verification Ltd. 0038 MED 1550175 13.10.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550176 13.10.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550192 27.08.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550193 07.09.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550194 13.10.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550198 07.08.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550199 07.08.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550200 07.08.2015

X

Lloyds Register Verification Ltd. 0038 MED 1550277 19.01.2016

X

Lloyds Register Verification Ltd. 0038 MED 1650011/ M1 19.01.2016

X

Lloyds Register Verification Ltd. 0038 MED 1650012 19.01.2016

X

Lloyds Register Verification Ltd. 0038 MED 1650013 19.01.2016

X

Page 450: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

450 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyds Register Verification Ltd. 0038 MED 1650014 19.01.2016

X

Lloyds Register Verification Ltd. 0038 MED 1650015 19.01.2016

X

Lloyds Register Verification Ltd. 0038 MED 1650016 25.01.2016

X

Lloyds Register Verification Ltd. 0038 MED 1650017 26.01.2016

X

Lloyds Register Verification Ltd. 0038 MED 1650065/ M1 13.04.2016

X

Lloyds Register Verification Ltd. 0038 MED 1650066/ M1 13.04.2016

X

Page 451: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

451 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint Ltd ...continued

Lloyds Register Verification Ltd. 0038 MED 1650105 24.03.2016

X MED 1550001/ M3

Lloyds Register Verification Ltd. 0038 MED 1750009 21.02.2017

X

Lloyds Register Verification Ltd. 0038 MED 1650210/ M1 13/ 09/ 2016

X

Lloyds Register Verification Ltd. 0038 MED1650211/ M1 13/ 09/ 2016

X

Lloyds Register Verification Ltd. 0038 MED 1650212/ M1 13/ 09/ 2016

X

Lloyds Register Verification Ltd. 0038 MED 1650213/ M3 17/ 11/ 2016

X

Lloyds Register Verification Ltd. 0038 MED 1650217/ M1 09/ 09/ 2016

X

Lloyds Register Verification Ltd. 0038 MED 1650218/ M1 13/ 09/ 2016

X

Lloyds Register Verification Ltd. 0038 MED 1650226 17/ 09/ 2016

X

International Paint of Shanghai Ltd, 1515 Xin Jin Qiao Road, Pudong 201206, Shanghai, China, People's Republic of.

A.1/3.18 Surface materials and floor coverings w ith low flame-spread characteristics - (b) paint systems

Lloyd’s Register Verification 0038 MED 1150238 & USCG Module B 164.112/ EC0038

X Expires: 23 August 2014

MED 1150214/ M1

Lloyd’s Register Verification 0038 MED 1150026 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0850244 & USCG Module B 164.112/ EC0038

X

Page 452: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

452 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1150017 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050175 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050172 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050224 & USCG Module B 164.112/ EC0038

X

Page 453: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

453 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint of Shanghai Ltd ...continued

Lloyd’s Register Verification 0038 MED 1050223 & USCG Module B 164.112/ EC0038

X MED 1150214/ M1

Lloyd’s Register Verification 0038 MED 1050227 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050225 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050226 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050230 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050228 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050229 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050176 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150149 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150041 & USCG Module B 164.112/ EC0038

X

Page 454: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

454 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1150047 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150100

& USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150028& USCG Module B 164.112/ EC0038

X

Page 455: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

455 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint of Shanghai Ltd ...continued

Lloyd’s Register Verification 0038 MED 1050231 & USCG Module B 164.112/ EC0038

X MED 1150214/ M1

Lloyd’s Register Verification 0038 MED 1150058 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950062 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950061/ M1 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950065 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950156 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950160 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950158 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950155 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950157 & USCG Module B 164.112/ EC0038

X

Page 456: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

456 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 0950159 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050244& USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150188 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150029 & USCG Module B 164.112/ EC0038

X

Page 457: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

457 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint of Shanghai Ltd ...continued

Lloyd’s Register Verification 0038 MED 1150188 & USCG Module B 164.112/ EC0038

X MED 1150214/ M1

Lloyd’s Register Verification 0038 MED 1150029 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150185 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150186 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150121 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150122 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150187 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150323 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150324 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150325 & USCG Module B 164.112/ EC0038

X

Page 458: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

458 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 0950102 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950103 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950104 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950105 & USCG Module B 164.112/ EC0038

X

Page 459: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

459 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint of Shanghai Ltd ...continued

Lloyd’s Register Verification 0038 MED 1050242 & USCG Module B 164.112/ EC0038

X MED 1150214/ M1

Lloyd’s Register Verification 0038 MED 1150120 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050232 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050234 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950344 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150027 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150030 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0850105 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0850245

& USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0850244 & USCG Module B 164.112/ EC0038

X

Page 460: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

460 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 0950143 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950033 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150276 & USCG Module B 164.112/ EC0038

X

Page 461: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

461 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint of Shanghai Ltd ...continued

Lloyd’s Register Verification 0038 MED 1150018 & USCG Module B 164.112/ EC0038

X MED 1150214/ M1

Lloyd’s Register Verification 0038 MED 0850104 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0850107 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050174 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1250058 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950064 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950144 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0950101 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 0850246 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1050321 & USCG Module B 164.112/ EC0038

X

Page 462: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

462 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1050173 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150031 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150032 & USCG Module B 164.112/ EC0038

X

Lloyd’s Register Verification 0038 MED 1150019 & USCG Module B 164.112/ EC0038

X

Page 463: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

463 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint of Shanghai Ltd ...continued

MED 1150326 & USCG Module B 164.112/ EC0038

X MED 1150214/ M1

A.1/3.18 Surface materials and floor coverings w ith low flame-spread characteristics - (c) floor coverings

Lloyd’s Register Verification 0038 MED 1150322 & USCG Module B 164.112/ EC0038 MED 1150224 & USCG Module B 164.112/ EC0038

X X

MED 1150223 & USCG Module B 164.112/ EC0038 MED 1050323 & USCG Module B 164.112/ EC0038 MED 1050322 & USCG Module B 164.112/ EC0038

X X X

MED 1150191 & USCG Module B 164.112/ EC0038 MED 1150192 & USCG Module B 164.112/ EC0038 MED 1150193 & USCG Module B 164.112/ EC0038

X X X

Page 464: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

464 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

MED 1150194 & USCG Module B 164.112/ EC0038 MED 1150195 & USCG Module B 164.112/ EC0038

X X

Page 465: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

465 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

International Paint of Shanghai Ltd ...continued

MED 1250058 & USCG Module B 164.112/ EC0038 MED 1150324 & USCG Module B 164.112/ EC0038

X X

MED 1150214/ M1

MED 1150024 & USCG Module B 164.117/ EC0038

X

Jessup M anufacturing Company, P.O. Box 366, 2815 West State Route 120, M cHenry, IL 60050, United States of America (USA).

A.1/ 3.40 Low-location lighting systems (components only)

Lloyd’s Register Verification 0038 MED 1550230/ M1 X Expires: 25 February 2020

MED 1750012

Jiangsu Huayan M arine Equipment Co. Ltd, No. 8 Huangjintang West Road, Danyang Economic Development Zone, Jiangsu, China, People's Republic of.

MED/ 3.41 - Emergency Escape Breathing Devices (EEBD)

Lloyds Register Verification 0038 MED 1750039 03/ 03/ 2017

X Expires: 6 April 2020

MED 1750070

MED 1750040 03/ 03/ 2017

X

Page 466: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

466 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

JM B Sp. z.o.o., ul. Polna 1, 84-240 Wejherowo, Poland.

A.1/ 3.21 – Bedding Components Lloyds Register Verification 0038 MED 1250001 03/ 01/ 2012 MED 1550245 12/ 10/ 2015 MED 1250189 02/ 10/ 2012 MED 1250043 19/ 03/ 2012 NC/ MED/ 031 28/ 04/ 2016

X X X X X

Expires: 9 March 2019

MED 1650121/ M1

Joiner Systems Technology Inc., 1925 52nd Avenue, Lachine, Quebec, H8T 3C3, Canada.

A.1/ 3.16 FIRE DOORS

Lloyd’s Register Verification 0038 MED 1650067 07-10-2015

X Expires: 8 August 2017

MED 1450193/ M3

Lloyd’s Register Verification 0038 MED 1650068 07-10-2015

X

Lloyd’s Register Verification 0038 MED 1450006 14-01-2014

X

Lloyd’s Register Verification 0038 MED 1650221 15/ 09/ 2016

X

Lloyd’s Register Verification 0038 MED 1750079 04/ 05/ 2016

X

Page 467: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

467 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Kidde Fire Protection, 1st Floor Stokenchurch House, Oxford Road, Stokenchurch, High Wycombe, Buckinghamshire, HP14 3SX, United Kingdom (UK).

Equivalent fixed gas fire extinguishing systems components (extinguishing medium, head valves and nozzles) for machinery spaces and cargo pump rooms

Lloyd’s Register Verification 0038 MED 1350173/ M1 21-Apr-2015

X Expires: 23 October 2017

MED 1450244/ M1

DNV 0575 MED-B-7962 28-Sep-2012

X

Page 468: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

468 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

La Auxiliar Naval, Playabarri 7, 48950 Lutxana-Erandio, Vizcaya, Spain.

A.1/ 3.25 Windows and side scuttles

Lloyd’s Register Verification 0038 MED 1450014 23 January 2014

X Expires: 31 October 2017

MED 1550017/ M2

Lloyd’s Register Verification 0038 MED 1250080 25 January 2012

X

Lloyd’s Register Verification 0038 MED 1250195/ M1 03 December 2012

X

Lloyd’s Register Verification 0038 MED 1250257 28 November 2012

X

Lloyd’s Register Verification 0038 MED 1250258 28 November 2012

X

0575 MEDB000002T 3 July 2015

X

0575 MED-B-7715 21 May 2012

X

0575 MED-B-9154 X

Leggett & Platt, 969 Corporate Blvd, Aurora, I llinois 60502, United States of America (USA).

A.1/ 3.18 Lloyds Register Verification 0038 MED 0950291/ M1 Issue Date: 22-Dec-2011

X Expires: 1 May 2018

MED 1550111/ M1

Page 469: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

469 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

LG Hausys Ltd, Surface M aterials Division Strategy Team, One IFC 18F, 10 Gookjegeumyoong_Ro,, Yeongdeungpo_Gu,, Seoul, 150-876, Korea, Republic of.

A.1/3.18a Surface materials & floor coverings with low flame-spread characteristics (a): Decorative Veneers

Lloyd’s Register Verification 0038 MED 1450003/ M1 10/ 12/ 2013

X Expires: 23 September 2018

MED 1550251

Page 470: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

470 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lopolight ApS, Ved Klaedebo 12B, Hoersholm, DK-2970, Denmark.

A.1/6.1 Navigation L:ights

QinetiQ EC0191 QQ-MED-15/ 09-01R 09 November 2010

X Expires: 19 December 2017

MED 1400015

QinetiQ EC0191 QQ-MED-15/ 09-02 09 November 2010

X

QinetiQ EC0191 QQ-MED-15/ 09-03 09 November 2010

X

QinetiQ EC0191 QQ-MED-15/ 09-04 09 November 2010

X

Lloyd’s Register Verification EC0038 MED 1350099 25 July 2013

X

Lorowerk K.H Vahlbrauk GmbH & Co. KG, Kriegerweg 1, 37581 Bad Gandersheim, Germany.

A.1/ 3.26 Penetrations through “ A” class divisions (b) pipe, duct, trunk, etc penetrations

Lloyd’s Register Verification 0038 MED 1650256 18/ 10/ 2016

X Expires: 9 November 2019

MED 1750005

Lloyd’s Register Verification 0038 MED 1650257 18/ 10/ 2016

X

Page 471: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

471 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ajilite Corporation, 1530 Broadway Road, Dracut, M assachusetts 01826 - 2830, United States of America (USA).

A.1/ 3.18(a) Fire Resisting Material

Lloyd’s Register Verification 0038 MED 1150328 USCG Module B 164.112/ EC0038 21-Dec-2011

X Expires: 14 March 2015

MED 1250046

Lloyd’s Register Verification 0038 MED 1150329 USCG Module B 164.112/ EC0038 21-Dec-2011

X

Lloyd’s Register Verification 0038 MED 0850215 USCG Module B 164.112/ EC0038 23-Jul-2008

X

Page 472: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

472 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ajilite Corporation ...continued

A.1/ 3.20 Fire Resisting Upholstery

Lloyd’s Register Verification 0038 MED 0850235 USCG Module B 164.144/ EC0038 31-Jul-2008

X MED 1250046

Lloyd’s Register Verification 0038 MED 1150330 USCG Module B 164.144/ EC0038 21-Dec-2011

X

Lloyd’s Register Verification 0038 MED 1150331 USCG Module B 164.144/ EC0038 21-Dec-2011

X

Lloyd’s Register Verification 0038 MED 1050268 USCG Module B 164.144/ EC0038 30-Sep-2010

X

M anifattura A Testori di G SpA, Via Dante 7, 20026 Novate M ilanese (M ilano), I taly.

A.1/ 3.18 Surface materials & floor coverings with low flame-spread characteristics (a): Decorative Veneers & (c): Floor Coverings

Lloyds Register Verification 0038 M ED 0497/075/08 18/03/2009

X ** NO CERT **

Lloyds Register Verification 0038 M ED 1150062 15/02/2011

X

Lloyds Register Verification 0038 M ED 0497/348/12 26/ 09/ 2012

X

Page 473: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

473 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

A.1/ 3.19 Draperies, curtains and other suspended textile materials and films

Lloyds Register Verification 0038 M ED 1150071 15/ 02/ 2011

X

A.1/ 3.20 Upholstered furniture

Lloyds Register Verification 0038 M ED 1150287 04/ 07/ 2011

X

Lloyds Register Verification 0038 M ED 1150064 15/ 02/ 2011

X

Lloyds Register Verification 0038 M ED 1150063 15/ 02/ 2011

X

A.1/ 3.21 Bedding Components

Lloyds Register Verification 0038 M ED 1150065 15/ 02/ 2011

X

Page 474: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

474 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M anifattura A Testori di G SpA ...continued

Lloyds Register Verification 0038 M ED 0497/395/13 14/ 05/ 2013

X ** NO CERT **

M ardtec Sp. z o.o, ul. Skrajna 1, Szpetal Gorny, Fabianki, 87-811, Poland.

MED/ 3.11 - ‘A’ and ‘B’ Class divisions Fire Integrity

0575 MEDB00001AW 28/ 08/ 2016

X Expires: 23 March 2022

MED 1750054

0575 MEDB00001AX 25/ 08/ 2016

X

0575 MEDB00001AY 22/ 11/ 2016

X

0575 MEDB00001AZ 22/ 11/ 2016

X

MED/ 3.16 - Fire Doors 2434 NC/ MED/ 038 15/ 09/ 2016

X

2434 NC/ MED/ 039 15/ 09/ 2016

X

M arine Electronics Co., 62, Gogwan-ro, Dong-gu, Busan, 601-836, Korea, Republic of.

MED/ 4.30 Electronic chart display and information system (ECDIS) with backup, and raster chart display system (RCDS)

Lloyds Register Verification Ltd. 0038 MED 1500020 19.10.2015

X Expires: 6 April 2018

MED 1550073/ M1

M arine Safety Supplies Ltd, Unit 2-3, M arine House, Willington Quay, Wallsend, Tyne & Wear, NE28 6SU, United Kingdom (UK).

A.1/4.49 Pilot Ladder

Lloyd’s Register Verification 0038 MED 1450127/ M1 17 June 2014

X Expires: 12 October 2018

MED 1550233

Page 475: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

475 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

A.1/1.29 Embarkation ladders

Lloyd’s Register Verification 0038 MED 1450128 17 June 2014

X

M arinefire s.r.l., Via Grecale 33, 55049 Viareggio (LU), I taly.

A.1/ 3.22 Fire dampers

Lloyds Register Verification 0038 MED 1250157/ M1 30.09.2016

X Expires: 17 April 2019

MED 1650131/ M1

MED 1650240 18.04.2016

X

Page 476: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

476 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M arinefire s.r.l. ...continued MED 1650241 18.04.2016

X MED 1650131/ M1

M CT Brattberg AB, Lyckeåborg, 371 92 Karlskrona, Sweden.

A.1/3.26(a) Penetrations through “ A” class divisions (a) Electric Cable Transits

Lloyd’s Register Verification 0038 MED 1650148 10/ 06/ 2016

X Expires: 5 January 2018

MED 1550037/ M1

Lloyd’s Register Verification 0038 MED 1650149 29/ 06/ 2016

X

A.1/3.26(b) Penetrations through “ A” class divisions (b) pipe, duct, trunk, etc penetrations

Lloyd’s Register Verification 0038 MED 1250096 05-May-2012

X

M etaalwarenfabriek & Kopergieterij "Het Anker" BV, Kaatsbaan 10, 4209 AD Schelluinen, Netherlands, The.

A.1/ 3.25 “A” and “B” class fire proof windows and side scuttles

RINA 0474 MED 020213CS 21.01.2013

X Expires: 19 October 2017

MED 1450194/ M3

Lloyds Register Verification Ltd 0038 MED 1250224 22.08.2012

X

Lloyds Register Verification Ltd 0038 MED 1250223 22.08.2012

X

RINA 0474 MED 053014CS 05.03.2014

X

RINA 0474 MED 099114CS 15.07.2014

X

RINA 0474 MED 060615CA001 21/ 12/ 2020

X

Page 477: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

477 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

RINA 0474 MED 151914CS/ 001 12.06.2014

X

RINA 0474 MED 151914CS/ 002 13.06.2014

X

RINA 0474 MED 307112CS 22.10.2012

X

RINA 0474 MED 347414CS 12.12.2015

X

RINA 0474 MED 217314CS/ 001 19.11.2014

X

RINA 0474 MED 217314CS/ 002 19.11.2014

X

RINA 0474 MED 217314CS/ 003 19.11.2014

X

Page 478: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

478 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M etaalwarenfabriek & Kopergieterij "Het Anker" BV ...continued

RINA 0474 MED050615CS-002 21.12.2015

X MED 1450194/ M3

RINA 0474 MED050615CS-003 21.12.2015

X

RINA 0474 MED050615CS-004 21.12.2015

X

RINA 0474 MED178916CS 20.06.2016

M etawell GmbH - metal sandwich technology, Schleifmühlweg 31, D-86633 Neuburg/Donau, Germany.

A.1/ 3.18(b) Surface materials and floor coverings w ith low flame-spread characteristics (b): Paint Systems

Lloyd’s Register Verification 0038 MED 1450007/ M1 And USCG Approval No. 164.112/ EC0038 07-February-2014

X Expires: 23 June 2014

MED 1450121/ M1

M I - M illenium International GmbH, Gustav-Rau-Strasse 8/1, Bietigheim-Bissingen, D-74321, Germany.

A.1/ 3.20 Upholstered Furniture

Lloyds Register Verification 0038 126.115 18.03.2016

X Expires: 31 October 2019

MED 1650261/ M1

M M L M arine Ltd, 60 Waverley Street, Coatbridge, North Lanarkshire, M L5 2BE, Scotland, United Kingdom (UK).

A.1/ 3.16 - Fire Doors Lloyd’s Register Verification 0038

MED 1350113/ M3 11-Sept-2015

X Expires: 20 September 2018

MED 1550244/ M2

Page 479: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

479 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1450201/ M2 06-July-2015

X

Lloyd’s Register Verification 0038 MED 1450223/ M2 06-July-2015

X

Lloyd’s Register Verification 0038 MED 1450235/ M2 06-July-2015

X

Lloyd’s Register Verification 0038 MED 1450246/ M2 06-July-2015

X

Lloyd’s Register Verification 0038 MED 1750071 26-May-2017

X

Page 480: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

480 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M organ Kailong (Jingmen) Thermal Ceramics CO., LTD., 20-1# Quankou Road, Jingmen City, Hubei Province, 448032, China, People's Republic of.

A.1/ 3.11 - “ A” and “ B” class division fire integrity

Lloyds Register Verification 0038 MED 1550224 02/ 11/ 2014

X Expires: 9 June 2018

MED 1550252/ M1

A.1/ 3.11 - “ A” and “ B” class division fire integrity

Lloyds Register Verification 0038 MED 1550225 02/ 11/ 2014

X

A.1/ 3.11 - “ A” and “ B” class division fire integrity

Lloyds Register Verification 0038 MED 1550226 02/ 11/ 2014

X

A.1/ 3.13 – Non-combustible Materials

Lloyds Register Verification 0038 MED 1650064 08/ 02/ 2016

X

M ors-Smitt B.V., Vrieslantlaan 6, 3526 AA Utrecht, Netherlands, The.

A.1/ 4.7 Speed and distance measuring equipment (SDM E)

Lloyds Register Verification Ltd. 0038 MED 1050349/ M3 22 May 2014

X Expires: 3 January 2018

MED 1550002

Lloyds Register Verification Ltd. 0038 MED 1300014 5 July 2013

X

A.1/ 4.9 Rate-of-turn indicator

Lloyds Register Verification Ltd. 0038 MED 1050348/ M3 22 May 2014

X

A.1/ 4.20 Rudder angle indicator

Lloyds Register Verification Ltd. 0038 MED 1000024/ M3 22 May 2014

X

Lloyds Register Verification Ltd. 0038 MED 1000031/ M3 22 May 2014

X

Lloyds Register Verification Ltd. 0038 MED 1300012 5 July 2013

X

Page 481: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

481 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyds Register Verification Ltd. 0038 MED 1050345/ M3 22 May 2014

X

A.1/ 4.21 Propeller revolution indicator

Lloyds Register Verification Ltd. 0038 MED 1050344/ M3 22 May 2014

X

Lloyds Register Verification Ltd. 0038 MED 1300011 5 July 2013

X

A.1/ 4.22 Pitch indicator

Lloyds Register Verification Ltd. 0038 MED 1050343/ M4 22 May 2014

X

Lloyds Register Verification Ltd. 0038 MED 1300013 5 July 2013

X

Page 482: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

482 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M SA Europe Gmbh, Schlusselstrasse 12, JONA, 8465, Switzerland.

A.1/ 3.6 Firefighter’s Outfit: Helmet

Lloyds Register Verification 0038 22371/ B1 EC 05/ 01/ 2016

X Expires: 13 October 2019

MED 1650262

22384/ B1 EC 05/ 01/ 2016

X

22385/ B1 EC 05/ 01/ 2016

X

38300/ A1 EC 05/ 01/ 2016

X

M ustang Survival ULC, 7525 Lowland Drive, Burnaby, BC, V5J 5L1, Canada.

A.1/1.6 – Immersion Suits & Anti Exposure Suits Classified as Lifejackets – Insulated or Non-Insulated

Lloyd’s Register Verification 0038 MED 1650111 29/ 11/ 2015

X Expires: 7 August 2017

MED 1450161/ M2

Lloyd’s Register Verification 0038 MED 1650076 10/ 01/ 2016

X

Lloyd’s Register Verification 0038 MED 1350096 17 July 2013

X

A.1/1.4 – Lifejackets

Lloyd’s Register Verification 0038 MED 1350034 26 March 2013

X

Lloyd’s Register Verification 0038 MED 1350035 26 March 2013

X

Netwave Systems BV, Blauw-Roodlaan 100, 2718 SJ Zoetermeer, Netherlands, The.

A.1/ 4.29 Voyage Data Recorder (VDR)

Bundesrepublik Deutschland 0735 BSH/ 46122/ 4292219/ 13 07/ 03/ 2013

X Expires: 21 December 2018

MED 1650073/ M2

X Bundesrepublik Deutschland 0735 4581/ 001/ 4292751

/ 15 10/ 08/ 2015

X

Page 483: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

483 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

A.1/ 4.47 Simplified Voyage Data Recorder (S-VDR)

Bundesrepublik Deutschland 0735 BSH/ 46122/ 4292219/ 13 07/ 03/ 2013

X

Bundesrepublik Deutschland 0735 4581/ 001/ 4472594/ 14 20/ 02/ 2014

X

Page 484: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

484 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Ningbo Kairong Ship M achinery Co. Ltd, No. 86 M ould Road Daqi Industrial Park, Beilun New District, Ningbo, 315806, China, People's Republic of.

A.1/1.23 Launching appliances for free-fall lifeboats

Lloyd’s Register Verification EC0038 MED 1050001 04-Jan-2010

X Expires: 19 May 2016

MED 1350054

Ningbo M eilin M achinery Co. Ltd., No. 1, Workhouse Export Processing Zone, Ningbo, 315806, China, People's Republic of.

A.1/ 3.2 Portable fire extinguishers

APRAGAZ 0029

09/ CN/ 1881-1-rev 0 03/ 11/ 2014

X Expires: 14 March 2018

MED 1650101

APRAGAZ 0029 09/ CN/ 1923-1-rev 0 03/ 11/ 2014

X

APRAGAZ 0029 09/ CN/ 1924-1-rev 0 03/ 11/ 2014

X

APRAGAZ 0029 09/ CN/ 1925-1-rev 0 03/ 11/ 2014

X

APRAGAZ 0029 09/ CN/ 1926-1-rev 0 03/ 11/ 2014

X

Page 485: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

485 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Northrop Grumman Sperry M arine BV, 118 Burlington Road, New M alden, Surrey, KT3 4NR, United Kingdom (UK).

A.1/4.30 - Electronic chart display and information system (ECDIS) with backup, and raster chart display system (RCDS)

0168 BABT-MED000051-02 30/ 04/ 2016

X

Expires: 31 December 2018

MED 1500031/ M1

Lloyds Register Verification 0038 MED 140004/ M2 21/ 07/ 2016

X

A.1/4.33 - Track control system (working at ship’s speed from minimum manoeuvring speed up to 30 knots)

Lloyds Register Verification 0038 MED 1400005/ M2 15/ 09/ 2016

X

A.1/4.34 - Radar equipment CAT 1 Lloyds Register Verification 0038 MED 1400002/ M2 21/ 07/ 2016

X

Lloyds Register Verification 0038 MED 1400006/ M2 21/ 07/ 2016

X

A.1/4.35 - Radar equipment CAT 2 Lloyds Register Verification 0038 MED 140003/ M2 21/ 07/ 2016

X

Page 486: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

486 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Northrop Grumman Sperry M arine BV ...continued

Lloyds Register Verification 0038 MED 1400007/ M2 21/ 07/ 2016

X MED 1500031/ M1

A.1/4.37 - Radar equipment for high-speed craft applications (CAT 1H, CAT 2H and CAT 3H)

Lloyds Register Verification 0038 MED 1400002/ M2 21/ 07/ 2016

X

Lloyds Register Verification 0038 MED 1400003/ M2 21/ 07/ 2016

X

Lloyds Register Verification 0038 MED 1400006/ M2 21/ 07/ 2016

X

Lloyds Register Verification 0038 MED 1400007/ M2 21/ 07/ 2016

X

A.1/4.38 - Radar equipment approved with a chart option, namely;

(a) CAT 1C (b) CAT 2C (c)CAT 1HC for HSC

(d) CAT 2HC for HSC

Lloyds Register Verification 0038 MED 1400002/ M2 21/ 07/ 2016

X

Lloyds Register Verification 0038 MED 1400003/ M2 21/ 07/ 2016

X

Lloyds Register Verification 0038 MED 1400006/ M2 21/ 07/ 2016

X

Lloyds Register Verification 0038 MED 1400007/ M2 21/ 07/ 2016

X

Ocean Safety Limited, Saxon Wharf, Lower York Street, Southampton, SO14 5QF, United Kingdom (UK).

A.1/ 1.4 Lifejackets

Lloyd's Register Verification

0038

MED 1150198/ M2 25 October 2013

X Expires: 28 August 2016

MED 1350139/ M2

Page 487: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

487 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Optimakers Oy, Sivutuuli 16, FIN-21600 Parainen, Finland.

A.1/ 3.18(a) Surface materials & floor coverings with low flame-spread characteristics (a): Decorative Veneers

VTT Technical Research Centre Of Finland

0809 VTT-C-6459-15-11 & USCG Module B No: 164.112/ EC00809 27-Janruary-2011

X Expires: 16 April 2017

MED 1250065

VTT Technical Research Centre Of Finland

0809 VTT-C-6458-15-11 & USCG Module B No: 164.112/ EC0809 27-Janruary-2011

X

Page 488: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

488 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Oy Lautex Ab, Ojakkalantie 13, P.O. Box 58, FIN-03101 Nummela, Finland.

A.1/ 3.11 (b) Lloyds Register Verification 0038 MED 1350006 10/ 03/ 2013

X Expires: 15 April 2020

MED 1750063

Lloyds Register Verification 0038 MED 1350007 10/ 03/ 2013

X

Lloyds Register Verification 0038 MED 1350018 13/ 02/ 2013

X

Lloyds Register Verification 0038 MED 1350019 13/ 02/ 2013

X

Lloyds Register Verification 0038 MED 1350030/ M1 10/ 10/ 2013

X

Lloyds Register Verification 0038 MED 1350031 13/ 03/ 2013

X

Lloyds Register Verification 0038 MED 1450011 01/ 01/ 2014

X

Lloyds Register Verification 0038 MED 1450085 21/ 01/ 2014

X

VTT Expert Services LTD 0809 VTT-C-11571-15-16 18/ 03/ 2016

X

A.1/ 3.18 VTT Expert Services LTD 0809 VTT-C-11541-15-16 10/ 02/ 2016

X

PANELSHIP, SLU, Poligono Industrial de A Lomba, Parroquia de Areas, Ponteareas, 36861, Ponteveda, Spain.

A.1/ 3.11 “ A” and “ B” class divisions fire integrity

Lloyd’s Register Verification 0038 MED 1250160 & USCG Module B 164.108/ EC0038 13-Sep-2012

X Expires: 4 July 2019

MED 1650166

Page 489: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

489 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1250161 & USCG Module B 164.108/ EC0038 13-Sep-2012

X

Lloyd’s Register Verification 0038 MED 1250187 & USCG Module B 164.108/ EC0038 02-Oct-2012

X

Page 490: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

490 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

PANELSHIP, SLU ...continued

Lloyd’s Register Verification 0038 MED 1250188/ M1 & USCG Module B 164.108/ EC0038 15-Apr-2013

X MED 1650166

A.1/ 3.16 Fire Doors

Lloyd’s Register Verification 0038 MED 1250162 & USCG Module B 164.136/ EC0038 13-Sep-2012

X

Lloyd’s Register Verification 0038 MED 1250163 & USCG Module B 164.136/ EC0038 13-Sep-2012

X

Lloyd’s Register Verification 0038 MED 1250164 & USCG Module B 164.136/ EC0038 13-Sep-2012

X

Pirotecnia Lecea S.A, Barrio Epiztegia 3, Larrea-Barrundia (Alava), Spain.

A.1/ 1.8 - Rocket Parachute Flare Veristar 0062 08839/ D0 EC 08/ 08/ 2014

X Expires: 2 October 2019

MED 1650247

A.1/ 1.9 - Hand Red Flare Veristar 0062 08840/ D1 EC 13/ 08/ 2016

X

Page 491: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

491 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

14457/ C0 EC 07/ 07/ 2016

X

A.1/ 1.10 - Buoyant Smoke Signals Veristar 0062 08841/ D0 EC 08/ 08/ 2014

X

Page 492: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

492 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Porkka Finland Oy, Huurretie 13, F133470 Ylöjärvi, Finland.

A.1/ 3.16 Fire Doors Lloyd’s Register Verification Lloyd’s Register Verification Lloyd’s Register Verification

0038 0038 0038

MED 1250054 12-Feb-2012 MED 1550258 19-Nov-2015 MED 1650209 15-Aug-2016

X X X

Expires: 3 July 2018

MED 1550183/ M1

Radio Zeeland DM P B.V., Industrieweg 17, 4538 AG Terneuzen, Netherlands, The.

A.1/ 4.16 Heading control system (HCS)

Lloyd’s Register 0038 MED130007 30-Apr-2013

X Expires: 25 April 2017

MED 1450116

A.1/ 4.2 Transmitting heading device THD (magnetic method)

Lloyd’s Register 0038 MED 1300001 9-Jan-2013

X

Recticel B.V., Schuilheuvelstraat 1, 4116 GA Buren, Netherlands, The.

A.1/ 3.18 Surface Materials & Floor Coverings With Low Flame-Spread Characteristics (c): Floor Coverings

Lloyd’s Register Verification 0038 MED 0850296 & USCG Module B No: 164.117/ EC0038 21-Oct-08

X Expires: 4 March 2016

MED 1350115

Lloyd’s Register Verification 0038 MED 0850297 & USCG Module B No: 164.117/ EC0038 21-Oct-08

X

Page 493: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

493 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

A.1/ 3.18c - Surface materials and floor coverings with low flame-spread characteristics (c) floor coverings

Lloyd’s Register Verification 0038 MED 1350135/ M1 25-Jun-2015 MED 1550150 25-Jun-2015

X X

Expires: 17 June 2018

MED 1550177

Recubrimientos Plasticos, Autovia Pamplona-Logrono, Salida 9, Astrain 31190, Navarra, Spain.

A.1/3.18(a) Surface materials and floor coverings w ith low flame-spread characteristics - (a) decorative veneers

Lloyd’s Register Verification 0038 MED 1450261 15 September 2014

X Expires: 28 January 2018

MED 1550048/ M1

Lloyd’s Register Verification 0038 MED 1450062 18 March 2014

X

Page 494: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

494 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Recubrimientos Plasticos ...continued

A.1/3.18(b) Surface materials and floor coverings w ith low flame-spread characteristics - (b) paint systems

Lloyd’s Register Verification 0038 MED 1350091 05 July 2013

X MED 1550048/ M1

Regatta AS, Borgundfjordveien 80, Alesund, N-6017, Norway.

A.1/ 1.4 Lifejackets

Lloyds Register Verification Ltd 0038 MED 0950072 5 March 2009

X Expires: 2 April 2016

MED 1350048

Lloyds Register Verification Ltd 0038 MED 0950073 5 March 2009

X

Roxtec GmbH, Neuer Holtigbaum 1-3, 22143 Hamburg, Germany.

A.1/ 3.26 Penetrations through “ A” class divisions (a) electric cable transits and (b) – PIPE, DUCT, TRUNK ETC. PENETRATIONS

Lloyd’s Register Verification 0038 MED 1450196/ M3 12/ 08/ 2016

X Expires: 31 July 2017

MED 1450160/ M3

Lloyd’s Register Verification 0038 MED 1450197/ M3 12/ 08/ 2016

X

Roxtec International AB, Rombvägen 2, Box 540, S-371 23 Karlskrona, Sweden.

A.1/3.26 Penetrations through “A” class divisions (b) pipe, duct, trunk, etc penetrations

Lloyd’s Register Verification 0038 MED 1150052/ M4 & USCG Module B No: 164.138/ EC0038 29 October 2012

X Expires: 31 March 2015

MED 1250051

A.1/3.27 Penetrations through “A” class divisions (b) pipe, duct, trunk, etc penetrations

Lloyd’s Register Verification 0038 MED 1150290/ M1 & USCG Module B No: 164.138/ EC0038 24 April 2012

X

Page 495: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

495 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai Aohan M arine Company, Room 21H, 428 Tianmuzhong Road, Shanghai, 200071, China, People's Republic of.

A.1/ 3.48 Fixed Water Based Local Application Fire Fighting Systems Components For Use In Category 'A ' Machinery Spaces

Lloyd’s Register Verification 0038 MED 0950365/ M1 28-Oct-2011

X Expires: 7 August 2016

MED 1350094

Shanghai Haishi Sports & Life Preservers Co., Ltd., 1-1-30 Kuboyoshi, Naniwa-ku, Osaka, 556-0028, Japan.

A.1/1.4 Lifejackets

Lloyd’s Register Verification 0038 MED 1650158 09/ 06/ 2016

X Expires: 14 September 2019

MED 1650219

Page 496: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

496 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai Haishi Sports & Life Preservers Co., Ltd. ...continued

Lloyd’s Register Verification 0038 MED 1650159 09/ 06/ 2016

X MED 1650219

Lloyd’s Register Verification 0038 MED 1650160 24/ 07/ 2016

X

0062 37475/ A0 EC 19/ 05/ 2016

X

A.1/1.5 Immersion Suits and anti-exposure suits not classified as lifejackets – insulated or non insulated

Lloyd’s Register Verification 0038 MED 1650161/ M1 19/ 07/ 2016

X

A.1/1.6 Immersion Suits and anti-exposure suits classified as lifejackets – insulated or non insulated

Lloyd’s Register Verification 0038 MED 1550148 26/ 04/ 2015

X

Shanghai Jiangnan Boatbuilding Co., Ltd., No. 999 Hailong Road, Fengxian District, Shanghai, China, People's Republic of.

A.1/ 1.17 LIFEBOATS

Lloyd’s Register Verification 0038 MED 1250011 03-Feb-2012

X Expires: 30 September 2015

MED 1250186/ M1

Lloyd’s Register Verification 0038 MED 1450154 08-Jul-2014

X

A.1/ 1.18 RIGID RESCUE BOATS

Lloyd’s Register Verification 0038 MED 1150148 20-May-2011

X

Page 497: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

497 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai Leading Industrial Company Limited, Rm 18c No. 2000 Pudong Da Dao, Free Trade Zone (Shanghai), Shanghai 200135, China, People's Republic of.

MED/ 3.19 – Draperies, Curtains & Other Suspended Textile Materials and Films

Lloyds Register 0038 MED 1750060 28/ 03/ 2017

X Expires: 22 April 2020

MED 1750077

Shanghai Rongde Engineering Equipment Co., Ltd, Room 1401, No. 1, Lane 1695, Pudong Avenue, Shanghai, 200135, China, People's Republic of.

A.1/ 2.2 Oil/ Water interface detector – Type UIT-100 and UIT-200

Lloyds Register Verification 0038 MED 1450167 30/ 07/ 2014

X Expires: 11 May 2019

MED 1650143/ M1

Page 498: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

498 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shanghai Rongde Engineering Equipment Co., Ltd ...continued

A.1/ 2.5 Oil Discharge monitoring and control system for an oil Tanker – Type RD-ODME-IIA

Lloyds Register Verification 0038 MED 1450038 19/ 02/ 2014

X MED 1650143/ M1

A.1/ 3.48 Fixed water based local application fire fighting systems components for use in category A machinery spaces – type FDFF

Lloyds Register Verification 0038 MED 1350038 31/ 01/ 2013

X

A.1/ 4.57 Bridge Navigational watch alarm System (BNWAS) – Type BNWAS-100

DNV 0575 MED-B-8164 21/ 03/ 2013

X

A.1/ 8.1 Water Level Detectors – type RDHL-D

Lloyds Register Verification 0038 MED 1300003 25/ 02/ 2013

X

Shengan Lighting (Kunshan) Co., Ltd., No. 238 Jingsong Road, Kunshan New & HI-Tech Industrial Development Zone, Kunshan City, Jiangsu Province, 215300, China, People's Republic of.

A.1/ 6.1 Navigation Lights Lloyd’s Register Verification 0038 Med 1150249 21-Sep-2011 MED 1150244 27-Jan-2011

X X

Expires: 3 July 2015

MED 1250129

Page 499: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

499 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

MED 1150245 21-Sep-2011 MED 1150243 21-Sep-2011 MED 1150247 21-Sep-2011

X X X

MED 1150246 21-Sep-2011 MED 1150248 21-Sep-2011

X X

Page 500: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

500 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shengan M arine Co.Ltd., 2 Chang Chun Street, Siaokang, Kaohsiung 81246, Taiwan.

A.1/6.1 Navigation lights

Lloyd’s Register Verification EC0038 MED 1350134 23/ 10/ 2013

X Expires: 18 July 2019

MED 1650196

Lloyd’s Register Verification EC0038 MED 1550201 11/ 08/ 2015

X

Lloyd’s Register Verification EC0038 MED 160012 23/ 06/ 2016

X

Lloyd’s Register Verification EC0038 MED 1350134 23/ 10/ 2013

A.1/4.52 Daylight signalling lamp

Lloyd’s Register Verification EC0038 MED 1450056 13/ 03/ 2014

X

Lloyd’s Register Verification EC0038 MED 1350146 06/ 11/ 2013

X

Shurtape Technologies (Changshu) Co. Ltd, No. 301 Yintong Road, Changshu Southeast EDZ, Cangshu, Jiangsu, 215500, China, People's Republic of.

MED/ 3.18a - Surface Materials & Floor coverings w ith low flame-spread Characteristics – Decorative Veneers

Lloyds Register Verification 0038 MED 1650138/ M2 25.04.2017

X Expires: 24 April 2020

MED 1750073

Spradling International GmbH, Walter-Boetcher-Str.7, D-21337 Lüneburg, Germany.

A.1/ 3.20 Upholstered furniture

Lloyd’s Register Verification 0038 MED 1250007/ M1 16/ 10/ 2015

X Expires: 17 June 2019

MED 1650195

Page 501: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

501 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1550237/ M1 12/ 01/ 2016

X

Sturm GmbH, Niederland 155, 5091 Unken, Austria.

A.1/3.16 Fire Doors

Lloyd’s Register Verification 0038 MED 1250198 & USCG No. 164.136/ EC0038 12/ 10/ 2012

X Expires: 31 December 2018

MED 1500002/ M1

Lloyd’s Register Verification 0038 MED 1650080 17/ 01/ 2016

X

Lloyd’s Register Verification 0038 MED 1650081 17/ 01/ 2016

X

Lloyd’s Register Verification 0038 MED 1650082 17/ 01/ 2016

X

Page 502: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

502 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Sturm GmbH ...continued Lloyd’s Register Verification 0038 MED 1650083 17/ 01/ 2016

X MED 1500002/ M1

Lloyd’s Register Verification 0038 MED 1650084 17/ 01/ 2016

X

Survitec Group Limited trading as RFD Beaufort Inc., 1420 Wolf Creek Trail, Sharon Centre, OH 44272, United States of America (USA).

A.1/ 1.2 Inflatable Liferafts

Lloyd’s Register Verification 0038 MED 1250241/ M4 27 January 2016

X Expires: 27 April 2018

MED 1550083/ M1

A.1/ 1.2 Inflatable Liferafts

Lloyd’s Register Verification 0038 MED 1250242/ M2 26 August 2015

X Expires: 27 April 2018

Tarkett Polska Sp. z o.o.Oddziaw Ja le, Ul. M ickiewicza 108, Jaslo, 38-200, Poland.

MED/ 3.18 – Surface Materials and floor coverings w ith low flame-spread Characteristics – C Floor Coverings

Lloyd Register 0038 MED 1650284 01/ 12/ 2016

X Expires: 2 March 2020

MED 1750061

MED 1750031/ M1 16/ 03/ 2017

X

MED 1750032/ M1 16.03.2017

X

Page 503: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

503 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Tecnicomar S.p.A., C/da Berbaro, 145/D, 91025 M arsala (TP), I taly.

A.1/ 2.6 Sewage Systems A.1/ 2.6 Sewage Systems A.1/ 2.6 Sewage Systems

Lloyd’s Register Verification Lloyd’s Register Verification Lloyds Register verification

0038 0038 0038

MED 1550293 22/ 12/ 2016 MED 1550294 22/ 12/ 2016 MED 1550295 22/ 12/ 2016

X X X

Expires: 28 May 2019

MED 1650164

A.1/ 2.6 Sewage Systems A.1/ 2.6 Sewage Systems A.1/ 2.6 Sewage Systems

Lloyds Register verification Lloyds Register verification Lloyds Register verification

0038 0038 0038

MED 1550296 22/ 12/ 2016 MED 1550297 22/ 12/ 2015 MED 1650019 14/ 01/ 2016

X X X

A.1/ 2.6 Sewage Systems

Lloyds Register verification

0038

MED 1650020 14/ 01/ 2016

X

Page 504: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

504 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Tecnicomar S.p.A. ...continued

A.1/ 2.6 Sewage Systems

Lloyds Register verification

0038

MED 1550040 18/ 02/ 2015

X MED 1650164

A.1/ 2.6 Sewage Systems

Lloyds Register verification

0038

MED 1550041 18/ 02/ 2015

X

A.1/ 2.6 Sewage Systems

Lloyds Register verification

0038

MED 1550042 18/ 02/ 2015

X

A.1/ 2.6 Sewage Systems

Lloyds Register verification

0038

MED 1550043 18/ 02/ 2015

X

A.1/ 2.6 Sewage Systems

Lloyds Register verification

0038

MED 1550044 18/ 02/ 2015

X

A.1/ 2.6 Sewage Systems

Lloyds Register verification

0038

MED 1550045 18/ 02/ 2015

X

A.1/ 2.6 Sewage Systems

Lloyds Register verification

0038

MED 1550046 18/ 02/ 2015

X

A.1/ 2.6 Sewage Systems

Lloyds Register verification

0038

MED 1550047 18/ 02/ 2015

X

A.1/ 2.6 Sewage Systems

Lloyds Register verification

0038

MED 1550146/ M1 06/ 07/ 2015

X

Temp Coat Brand Products LLC, 301 W. Airline hwy., Suite 100, LaPlace, LA, 70068, United States of America (USA).

A.1/ 3.18 - SURFACE M ATERIALS AND FLOOR COVERINGS WITH LOW FLAM E-SPREAD CHARACTERISTICS - (d) PIPE INSULATION COVERS

Lloyds Register Verification 0038 MED 1650222 15/ 07/ 2016

X Expires: 18 June 2017

MED 1450140/ M1

Page 505: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

505 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

The Amtico Company Limited, Kingfield Road, Coventry, West M idlands, CV6 5AA, United Kingdom (UK).

A.1/3.18 surface materials & floor coverings with low flame-spread characteristics (c): floor coverings

Lloyd’s Register Verification 0038 MED 1650248 28/ 09/ 2016

X Expires: 21 November 2017

MED 1450237/ M2

Lloyd’s Register Verification 0038 MED 1450102/ M2 08 Jan 2015

X

The Coleman Company Inc., 3600 North Hydraulic, Wichita, KS 67219, United States of America (USA).

A.1/1.5 Immersion suits and anti-exposure suits not classified as lifejackets:

Insulated or not insulated

Lloyd’s Register Verification 0038 MED 1450106 06 February 2014

X Expires: 21 August 2018

MED 1550178/ M2

Page 506: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

506 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

The Coleman Company Inc. ...continued

A.1/1.6 Immersion suits and anti-exposure suits classified as lifejackets: Insulated or non-insulated

Lloyd’s Register Verification 0038 MED 1450104 06 February 2014

X MED 1550178/ M2

A.1/1.4 Lifejackets

Lloyd’s Register Verification 0038 MED 1650270 17/ 09/ 2016

X

Lloyd’s Register Verification 0038 MED 1650269 17/ 09/ 2016

X

Lloyd’s Register Verification 0038 MED 1650268 17/ 09/ 2016

X

Tianjin Sealantern Electronics Co. Ltd, No. 6, Zhuyuan Road, Huayuan Industrial District, Tianjin, China, People's Republic of.

A.1/ 4.29 Voyage data recorder (VDR)

Lloyd’s Register Verification 0038 MED 1600003/ M1 02/ 03/ 2016

X Expires: 5 February 2019

MED 1650086/ M1

A.1/ 8.1 Water level detectors

Lloyd’s Register Verification 0038 MED 1200010 04-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1200011 04-Oct-2012

X

Torginol-Teollisuuslattiat Oy, Billskogintie 31, 02580 Siuntio, Finland.

A.1/ 3.1 Primary Deck Coverings

Lloyd’s Register Verification 0038 MED 1650117 19.01.2016

X Expires: 15 December 2017

MED 1450245/ M1

Page 507: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

507 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

TROX M alaysia Sdn. Bhd., 20 Persiaran Bunga Tanjung 1, Senawang Land Industrial Park, 70400 Seremban, Negeri Sembilan, M alaysia.

A.1/ 3.22 Fire Dampers

Lloyd’s Register Verification 0038 MED 1550149 24/ 03/ 2015

X Expires: 23 March 2018

MED 1550149

Tyco Fire & Security GmbH, Victor Von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Schaffhausen, Switzerland.

A.1/ 3.51 Fixed Fire Detection And Fire Alarm Systems Components For Control Stations, Service Spaces, Accommodation Spaces, Cabin Balconies, Machinery Spaces And Unattended Machinery Spaces

Lloyd’s Register Verification 0038 MED 11500010 02/ 0725

X Expires: 7 October 2019

MED 1650245

Page 508: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

508 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Tyco Fire & Security GmbH ...continued

Lloyd’s Register Verification 0038 MED 11500012 04/ 08/ 15

X MED 1650245

Lloyd’s Register Verification 0038 MED 11500013 04/ 08/ 15

X

Lloyd’s Register Verification 0038 MED 11500014 04/ 08/ 15

X

Lloyd’s Register Verification 0038 MED 11500015 04/ 08/ 15

X

Lloyd’s Register Verification 0038 MED 11500016 04/ 08/ 15

X

Lloyd’s Register Verification 0038 MED 1200006/ M2 22/ 07/ 15

X

A.1/ 3.53 Alarm Devices Lloyd’s Register Verification 0038 MED 1300008/ M1 21/ 07/ 14

X

Tyco Fire Products M anufacturing Limited, Stockport Trading Estate, Yew Street, Stockport, SK4 2JW, United Kingdom (UK).

MED/ 3.28 Sprinkler systems (limited to sprinkler heads)

Lloyd’s Register Verification 0038 MED 1650133 06/ 04/ 2016

X Expires: 4 May 2020

MED 1750052

MED/ 3.48 Fixed Water-based local application fire-fighting systems components for use in category “ A” machinery spaces.

0062 19996/ B0 EC 17 October 2012

X

Page 509: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

509 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Tyco Fire Protection Products, Burlington House, Hewett Road, Gapron Hall Industrial Estate, Great Yarmouth, Norfolk, United Kingdom (UK).

A.1/ 3.45 Lloyds Register Verification 0038 MED 1650170/ M2 28/ 04/ 2017

X Expires: 17 May 2018

MED 1550154/ M2

MED 1650171 13/ 09/ 2016

X

MED 1650172/ M1 28/ 04/ 2017

X

Page 510: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

510 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Ultra Fog AB, Backa Strandgata 18, Hisings Backa, 422 46, Sweden.

A.1/ 3.9 Sprinkler systems components for accommodation spaces, service spaces and control stations equivalent to that referred to in SOLAS 74 Reg. I I -2/12 (limited to nozzles and their performance)

Lloyds Register Verification Ltd. 0038 MED 1450095/ M1 26/ 05/ 2016

X Expires: 17 March 2019

MED 1650163

A.1/ 3.39 Nozzles for equivalent water-mist fire extinguishing systems for machinery spaces and cargo pumps rooms

Lloyds Register Verification Ltd. 0038 MED 1450249/ M1 26/ 05/ 2016

X

A.1/ 3.43 Nozzles for deep fat cooking equipment fire extinguishing systems (automatic or manual type)

Lloyds Register Verification Ltd. 0038 MED 1550206/ M1 26/ 05/ 2016

X

A.1/ 3.48 Fixed water based local application fire fighting systems components for use in category “A” machinery spaces (nozzles and performance tests)

Lloyds Register Verification Ltd. 0038 MED 1450078/ M1 26/ 05/ 2016

X

A.1/ 3.49 Nozzles for fixed water-based fire-fighting systems for ro-ro spaces and special category spaces equivalent to that referred to in resolution A.123(V)

Lloyds Register Verification Ltd. 0038 MED 1450076/ M1 26/ 05/ 2016

X

Page 511: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

511 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

A.1/ 3.60 Nozzles for fixed pressure water-spraying fire-extinguishing systems for cabin balconies

Lloyds Register Verification Ltd. 0038 MED 1450077/ M1 26/ 05/ 2016

X

Van Dam B.V., Plaza 16, 4782 SK M OERDIJK, Netherlands, The.

MED/ 3.16 – Fire Doors 0575 MEDB0000W1 17/ 06/ 2016

X Expires: 3 April 2020

MED 1750076

MED/ 3.16 – Fire Doors 0575 MEDB000016B 17/ 06/ 2016

X

MED/ 3.16 – Fire Doors 0575 MEDB000016C 17/ 06/ 2017

X

MED/ 3.25 - “ A” and “ B” Class fire proof windows and side scuttles

0062 44228/ A0 EC 23/ 02/ 2016

X

MED/ 3.16 – Fire Doors Lloyds Register Verification 0038 MED 1550080 11/ 03/ 2015

X

Page 512: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

512 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Van Dam B.V. ...continued MED/ 3.16 – Fire Doors Lloyds Register Verification 0038 MED 1350126 20/ 10/ 2013

X MED 1750076

MED/ 3.16 – Fire Doors Lloyds Register Verification 0038 MED 1550078 11/ 03/ 2015

X

MED/ 3.16 – Fire Doors Lloyds Register Verification 0038 MED 1550050/ M1 07/ 04/ 2015

X

MED/ 3.25 - “ A” and “ B” Class fire proof windows and side scuttles

Lloyds Register Verification 0038 MED 1450198/ M1 07/ 10/ 2014

X

MED/ 3.16 – Fire Doors Lloyds Register Verification 0038 MED 1750045 14/ 03/ 2017

X

Vanguard M arine LDA, Zona Industrial No. 1 Campos, 4920-012 Vilanova De Cerveira, Viana, Portugal.

A.1/1.43 Rigid/ inflated rescue boats

Lloyd’s Register Verification 0038 MED 1450178/ M1 15 September 2014

X Expires: 30 September 2017

MED 1450239

Verhoef Aluminium Scheepsbouw Industrie BV, M olenweg 125, 1436 BS Aalsmeerderbrug, Netherlands, The.

A.1/ 1.17 Lifeboats

Lloyd’s Register Verification EC0038 MED 1250165 14/ 09/ 2012

X Expires: 30 November 2020

MED 1550247

MED 1450034/ M1 19/ 06/ 2014

X

Page 513: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

513 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Vescom B.V., St. Jozefstraat 20, 5753 AV Deurne, Netherlands, The.

A.1/3.18 Surface materials & floor coverings with low flame-spread characteristics (a): Decorative Veneers

Lloyds register verification 0038 1450101 01/ 05/ 2014 MED 1750034/ M1 08/ 03/ 2017

X Expires: 17 February 2019

MED 1650125/ M1

A.1/3.19 Draperies, Curtains and other suspended textile M aterials and films

0736 122.144 02/ 04/ 2014

X

0736 122.181 19/ 09/ 2012

A.1/3.20 Upholstered Furniture

Lloyds register verification 0038 1250246 05/ 10/ 2012

X

0736 126.055 23/ 04/ 2014

X

Page 514: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

514 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wartsila Suzhou Limited, 77 Hongxi Road, Suzhou New District, Jiangsu Province, 215151, China, People's Republic of.

A.1/ 2.6 Sewage Treatment Plants

Lloyd’s Register Verification 0038 MED 0950346 15-Dec-2009

X Expires: 18 June 2017

MED 1450159/ M2

Lloyd’s Register Verification 0038 MED 1050054 10-Mar-2010

X

Lloyd’s Register Verification 0038 MED 1050193 4-Aug-2010

X

Lloyd’s Register Verification 0038 MED 1150119 18-Apr-2011

X

Lloyd’s Register Verification 0038 MED 1250200 19-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250203 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250204 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250205 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250206 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250207 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250208 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250209 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250210 22-Oct-2012

X

Page 515: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

515 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1250211 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250212 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250213 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250214 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250215 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250216 22-Oct-2012

X

Page 516: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

516 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wartsila Suzhou Limited ...continued

Lloyd’s Register Verification 0038 MED 1250037/ M1 15-Nov-2012

X MED 1450159/ M2

Lloyd’s Register Verification 0038 MED 1250038/ M1 15-Nov-2012

X

Lloyd’s Register Verification 0038 MED 1250039/ M1 15-Nov-2012

X

Lloyd’s Register Verification 0038 MED 1250040/ M1 15-Nov-2012

X

Lloyd’s Register Verification 0038 MED 1250234 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250236 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250237 22-Oct-2012

X

Lloyd’s Register Verification 0038 MED 1250175/ M1 15-Nov-2012

X

Lloyd’s Register Verification 0038 MED 1350107 09-Aug-2013

X

Lloyd’s Register Verification 0038 MED 1450018 31-Jan-2014

X

Lloyd’s Register Verification 0038 MED 1450019 31-Jan-2014

X

Lloyd’s Register Verification 0038 MED 1450020 31-Jan-2014

X

Lloyd’s Register Verification 0038 MED 1450021 31-Jan-2014

X

A.1/ 3.42 Inert Gas System Components

DNV 0575 MED-B-7856 21-Jun-2012

X

A.1/ 3.42 Inert Gas System Components

DNV 0575 MED-B-7857 21-Jun-2012

X

Page 517: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

517 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

A.1/ 2.10 On board exhaust gas cleaning system

DNV 0575 MED-B-8812 10-Mar-2014

X

Wartsila Water Systems Ltd., Fleets Corner, Poole, Dorset, BH17 0JT, United Kingdom (UK).

A.1/ 2.6 Sewage Treatment Plants

Lloyd’s Register Verification 0038 MED 1550022 30/ 01/ 2015

X Expires: 14 December 2018

MED 1550290/ M4

Lloyd’s Register Verification 0038 MED 1550023 30/ 01/ 2015

X

Lloyd’s Register Verification 0038 MED 1550024 30/ 01/ 2015

X

Page 518: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

518 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wartsila Water Systems Ltd. ...continued

Lloyd’s Register Verification 0038 MED 1550025 30/ 01/ 2015

X MED 1550290/ M4

Lloyd’s Register Verification 0038 MED 1550026 30/ 01/ 2015

X

Lloyd’s Register Verification 0038 MED 1550027 30/ 01/ 2015

X

Lloyd’s Register Verification 0038 MED 1550028 30/ 01/ 2015

X

Lloyd’s Register Verification 0038 MED 1550029 30/ 01/ 2015

X

Lloyd’s Register Verification 0038 MED 1550030 30/ 01/ 2015

X

Lloyd’s Register Verification 0038 MED 1550031 30/ 01/ 2015

X

Lloyd’s Register Verification 0038 MED 1550032 30/ 01/ 2015

X

Lloyd’s Register Verification 0038 MED 1550033 30/ 01/ 2015

X

Lloyd’s Register Verification 0038 MED 1550034 30/ 01/ 2015

X

Lloyd’s Register Verification 0038 MED 1550035 30/ 01/ 2015

X

Lloyd’s Register Verification 0038 MED 1550051/ M1 13/ 03/ 2015

X

Lloyd’s Register Verification 0038 MED 1550052 04/ 03/ 2015

X

Lloyd’s Register Verification 0038 MED 1550053 04/ 03/ 2015

X

Lloyd’s Register Verification 0038 MED 1550054 04/ 03/ 2015

X

Page 519: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

519 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Lloyd’s Register Verification 0038 MED 1550055 04/ 03/ 2015

X

Lloyd’s Register Verification 0038 MED 1550257 19/ 11/ 2015

X

Lloyd’s Register Verification 0038 MED 1250091 17/ 05/ 2012

X

Lloyd’s Register Verification 0038 MED 1550038 09/ 02/ 2015

X

Lloyd’s Register Verification 0038 MED 1550250 06/ 11/ 2015

X

Lloyd’s Register Verification 0038 MED 1650263 07/ 11/ 2016

X

Page 520: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

520 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Wartsila Water Systems Ltd. ...continued

Lloyd’s Register Verification 0038 MED 1750028 27/ 02/ 2017

X MED 1550290/ M4

Lloyd’s Register Verification 0038 MED 1750029 27/ 02/ 2017

X

A.1/ 2.1 – Oil Filtering Equipment (for an oil content of the effluent not exceeding 1 5 p.p.m

DNV GL AS 0575 MEDB00000N2 02/ 02/ 2016

X

DNV GL AS 0575 MEDB000010V 28/ 04/ 2016

X

Weihai Shanhua Huabao Carpet Co., Ltd., No. 118, Wenquan Road, Huancui District, Shanhua Industrial Park, Weihai City, Shangdong, China, People's Republic of.

A.1/ 3.18 Surface materials and floor coverings with low flame-spread characteristics (c) floor coverings

Lloyds Register Verification Ltd. 0038 MED-B7783 X Expires: 7 April 2018

MED 1550074

Wilhelmsen Ships Services, Strandveien 20, 1366 Lysaker, Norway.

A.1/ 3.30 Portable Oxygen Analysis & Gas Detection Equipment

Llyods Register Verification 0038 MED 1500023 17/ 11/ 2015 MED 1500024 17/ 11/ 2015 MED 1500026 17/ 11/ 2015 MED 1500028 17/ 11/ 2015

X X X X

Expires: 17 November 2018

MED 1550255

Page 521: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

521 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Witt & Sohn A.G., Ziegeleiweg 38, 25421 Pinneberg, Germany.

A.1/ 3.22 Fire Dampers

Lloyd’s Register Verification 0038 MED 1650273 10/ 11/ 2016

X Expires: 31 March 2020

MED 1750057

Work Ribs Holland BV, Het Nieuwe Werk 40, 1781 AL Den Helder, Netherlands, The.

A.1/1.20 Fast Rescue Boats

Lloyd's Register Verification 0038 MED 1650208/ M1 18/ 10/ 2016

X Expires: 16 November 2017

MED 1500001/ M2

Lloyd's Register Verification 0038 MED 1650290 05/ 12/ 2016

X

Page 522: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

522 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Work Ribs Holland BV ...continued

A.1/1.20 Fast Rescue Boats & A.1/1.43 Rigid/Inflated Rescue Boats

Lloyd's Register Verification 0038 MED 1250192/ M1 16-Oct-2012

X MED 1500001/ M2

Wuxi Nuorui Electronic Technology Co., Ltd, Room 0901, Building 3,, No. 311, Yanxin Road,, Huishan Economic Development Zone,, Wuxi, Jiangsu Province,, 214174, China, People's Republic of.

A.1/ 4.30 ELECTRONIC CHART DISPLAY AND INFORM ATION SYSTEM (ECDIS) WITH BACKUP, AND RASTER CHART DISPLAY SYSTEM (RCDS)

Lloyds Register Verification 0038 MED 1500030 25 November 2015

X Expires: 10 March 2019

MED 1650124

Xiantao Deming Healthcare Products Co., Ltd, No.198, Pengchang Ave, Xiantao City, Hubei, China, People's Republic of.

A.1/ 1.7 Thermal Protective Aids

Lloyds Register Verification 0038 MED 1550036 3/ 02/ 2015

X Expires: 16 February 2019

MED 1650075

Zodiac Hurricane Technologies Inc., 7830 Vantage Way, Delta, British Columbia, V4G 1A7, Canada.

A.1/ 1.43 Rigid/ inflated rescue boats

Lloyd’s Register Verification 0038 MED 1350161/ M1 10 Sept 2016 MED 1550161 7 April 2015

X X

Expires: 23 March 2020

MED 1750044

Page 523: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: M ED Product Surveillance Product: M ED M ODULE (M ED 96/98/EC)

Type Examination Module B Surveillance

Module

Producer Product and Type Notified Body N o Cert N o & Issue Date D E F Remarks Cert. No.

523 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

A.1/ 1.20 Fast Rescue Boats

Lloyd’s Register Verification 0038 MED 1650151 20 May 2016 MED 1550240/ M2 09 June 2016

X X

Zodiac M ilpro UK Limited, Dafen, Llanelli, Carmarthenshire, SA14 8NA, United Kingdom (UK).

A.1/ 1.20 Fast rescue boats (c) rigid-inflated

Lloyd’s Register Verification EC0038 MED 1450165 31 July 2014

X Expires: 31 July 2017

MED 1450169

Page 524: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.16 HEADING CONTROL SYSTEM (HCS) (FORM ERLY AUTO-PILOT)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

524 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Radio Zeeland DM P B.V., Industrieweg 17, 4538 AG Terneuzen, Netherlands, The.

Type: Seapilot 75/ ECO 510

Autopilot ISO 11674:2006 IEC 60945 (2002) IEC 61162 Series IEC 62288 Ed.1.0(2008)

Expires: 18 April 2016

MED 1100002

Seapilot 76 Heading Control System IEC 60945:2002 incl. Corr.1:2008 IEC 61162 series ISO 11674 (2006) IEC 62288 (2008)

Expires: 29 April 2018

MED 1300007

Page 525: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.2 TRANSM ITTING M AGNETIC HEADING DEVICE THD (M AGNETIC M ETHOD)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

525 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Radio Zeeland DM P B.V., Industrieweg 17, 4538 AG Terneuzen, Netherlands, The.

Sigma 345 Transmitting magnetic heading device IEC 60945:2002 incl. Corr.1:2008 IEC 61162 series ISO 22090-2 (2004) incl. Corr.:2005 IEC 62288 (2008)

Expires: 8 January 2018

MED 1300001

Page 526: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.20 RUDDER ANGLE INDICATOR

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

526 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ors-Smitt B.V., Vrieslantlaan 6, 3526 AA Utrecht, Netherlands, The.

Type: S4v96S, S4v144S, S4v96S/ 66 & S4v144S/ 66

Indicators IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) ISO 20673:2007

Expires: 27 November 2019 The indicators are only to be installed on board w ith a: 1) MED certified transmitter;

MED 1000031/ M4

Type: Dv48S, Dv72S, Dv96S, Dv144S, D3v48S, D3v72S, D3v96S, D3v144S, D3v144S/ AMP, D3v192S, D3V192S/ AMP, Dv48S/ 66, Dv72S/ 66, Dv96S/ 66, Dv144S/ 66, D3v48S/ 66, D3v72S/ 66, D3v96S/ 66, D3v144S/ 66, D3v144S/ AMP/ 66, D3v192S/ 66, & D3V192S/ AMP/ 66 Including Signal Correction Box (SCB-V)

Indicators IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) ISO 20673:2007

Expires: 27 November 2019 The indicators are only to be installed on board w ith a: 1) MED certified transmitter; and 2) Mors-Smitt Signal Correction Box

MED 1050345/ M4

Rudder Overhead Indicator Type RCI-400 Including SCB

Voltage (VDC): 9 and 24 Illumination Current (mA): 250 Servo Supply Current (mA): 70, 75 & 115

EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008) ISO 20673 (2007)

Expires: 10 August 2020 To be used in conjunction Nieaf-Smitt B.V Signal Control Box SCB-V or equivalent MED certified solution

MED 1500017

For the use in enclosed areas that are not susceptible to salt mist only

Page 527: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.20 RUDDER ANGLE INDICATOR

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

527 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ors-Smitt B.V., Vrieslantlaan 6, Utrecht, 3502KA, Netherlands, The.

Type: SXv96/ A-1, SXv96/ CAN, SXv96/ 66/ A-1, SXv96/ 66/ CAN

Rudder angle indicator IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) ISO 20673 (2007) IEC 62288 (2008)

Expires: 4 July 2018

MED 1300012

Page 528: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.21 PROPELLER REVOLUTION INDICATOR

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

528 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ors-Smitt B.V., Vrieslantlaan 6, 3526 AA Utrecht, Netherlands, The.

Type: Dv48S, Dv72S, Dv96S, Dv144S, D3v48S, D3v72S, D3v96S, D3v144S, D3v144S/ AMP, D3v192S, D3V192S/ AMP, Dv48S/ 66, Dv72S/ 66, Dv96S/ 66, Dv144S/ 66, D3v48S/ 66, D3v72S/ 66, D3v96S/ 66, D3v144S/ 66, D3v144S/ AMP/ 66, D3v192S/ 66, & D3V192S/ AMP/ 66 Including Signal Correction Box (SCB-V)

Indicators IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) ISO 22554:2007

Expires: 27 November 2019 The indicators are only to be installed on board w ith a: 1) MED certified driving unit and transmitter w ith a suitable junction box or MED certified revolution sensor and signal converter; and 2) Mors-Smitt Signal

MED 1050344/ M4

Correction Box

M ors-Smitt B.V., Vrieslantlaan 6, Utrecht, 3502KA, Netherlands, The.

Type: SXv96/ A-1, SXv96/ CAN, SXv96/ 66/ A-1, SXv96/ 66/ CAN

Propeller revolution indicator IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) ISO 22554 (2007) IEC 62288 (2008)

Expires: 4 July 2018

MED 1300011

Page 529: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.22 PITCH INDICATOR

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

529 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ors-Smitt B.V., Vrieslantlaan 6, 3526 AA Utrecht, Netherlands, The.

Type: Dv48S, Dv72S, Dv96S, Dv144S, D3v48S, D3v72S, D3v96S, D3v144S, D3v144S/ AMP, D3v192S, D3V192S/ AMP, Dv48S/ 66, Dv72S/ 66, Dv96S/ 66, Dv144S/ 66, D3v48S/ 66, D3v72S/ 66, D3v96S/ 66, D3v144S/ 66, D3v144S/ AMP/ 66, D3v192S/ 66, & D3V192S/ AMP/ 66 Including Signal Correction Box (SCB)

Indicators IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) ISO 20673:2007

Expires: 27 November 2019 The indicators are only to be installed on board w ith a: 1) MED certified transmitter; and 2) Mors-Smitt Signal Correction Box

MED 1050343/ M5

M ors-Smitt B.V., Vrieslantlaan 6, Utrecht, 3502KA, Netherlands, The.

Type: SXv96/ A-1, SXv96/ CAN, SXv96/ 66/ A-1, SXv96/ 66/ CAN

Pitch indicator IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) ISO 22555 (2007) IEC 62288 (2008)

Expires: 4 July 2018

MED 1300013

Page 530: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.29 Voyage Data Recoder (VDR)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

530 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Sealantern Electronics Co. Ltd., No. 6 Zhuyuan Road, Huayuan Industrial Park, Tianjin 300384, China, People's Republic of.

SLT-18C VDR (Software Version 1.1) Comprising Recording Control Unit Interior Microphone Alarm Panel Compass Digital Interface Radar Video Converter Power Supply Unit Exterior Microphone

Annex A.1/ 4.29 Voyage Data Recorder (VDR)

IEC60945(2002) including IEC 60945 Corrigendum 1(2008), IEC 61162 Series, IEC 61996-1 (2013-05), IEC 62288 Ed. 1.0 (2008)

Expires: 7 January 2021

MED 1600003/ M1

PDC Junction Box Speed Log interface Float-free protective Capsule Data Acquisition Unit Protected Data Capsule Port Junction Box VHF Audio Interface

Page 531: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.30 Electronic Chart Display & Info System ECDIS with backup, and raster chart display syste

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

531 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Haihua Electronics Enterprise (China) Corporation, 163 Pingyun Road, West of Huangpu Avenue, Guangzhou 510656, China, People's Republic of.

A.1/ 4.30 Electronic chart display and information system (ECDIS) Type CH-01 ECDIS Software version 1.0, identification HGSTC-UT-C1102401-P1V1.0

Processor unit EDM-1 Diplay units EDD-1 or EDD-2 Control unit EDC-1 Network interface unit EDI-1

IEC 60945 (2002) IEC 61162 Series IEC 61174 (2008) IEC 62288 Ed.1.0 (2008)

Expires: 10 April 2017

MED 1200004

M arine Electronics Co., 62, Gogwan-ro, Dong-gu, Busan, 601-836, Korea, Republic of.

ECDIS Hardware:

PM 3D2 ECDIS IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) IEC 61174 (2008) IEC 62288 Ed. 1 (2008) IEC 61162-1 (2010), IEC 61162-2 (1998)

Expires: 18 October 2020 The following standards are not applicable for this equipment: • IEC 61162-3 ed1.1 Consol. With am1 (2010-11),

MED 1500020

Read as one Table

Read as one Table

• IEC 61162-3 ed1.0 (2008-05) • IEC 61162-3-am1 ed1.0 (2010-06) Amendment 1 IEC 61152-450 ed1.0 (2011-06).

Page 532: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.30 Electronic Chart Display & Info System ECDIS with backup, and raster chart display syste

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

532 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

I tem: Type: Computer HTB22GG Computer HTCO2HJ STC-xxx- Axx HTCO2HJ STC-xxx- Dxx 19” Display Series X HD19T21STD-MAE- FAGA 23” Display Series X JH23T14 MMD-Mxx- xxBx

M anufacturer: Hatteland Display AS Hatteland Display AS Hatteland Display AS Hatteland Display AS Hatteland Display AS

24” Display Series X HD24T21STD-MAE- FAGA 26” Display Series X HD26T21STD-MAE- FAGA 19” Panel Series X HD19T21 MEC- Mxx-xxBx

Hatteland Display AS Hatteland Display AS

Page 533: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.30 Electronic Chart Display & Info System ECDIS with backup, and raster chart display syste

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

533 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M arine Electronics Co. ...continued

24” Panel Series X HD24T21 MEC-Mxx- xxBx 26” Panel Series X HD26T21 MEC-Mxx- xBx Serial Interface NPort 5430I Keyboard w ith trackball KSML106 F0001-W-MC1 Keyboard w ith trackball KSMX106 F0001-W-MC1

Hatteland Display AS Hatteland Display AS MOXA Inc. NSI NSI

MED 1500020

Keyboard w ith trackball KSML92 F0001-W-MC1 Keyboard w ith trackball KSML103 F0001-USB- WLED Keyboard w ith Querty & trackball Trackball 388*188mm

NSI NSI Keytouch Technology AS

Network switch EDS G308 ECDIS Software: PM3D2 ECDIS Version 2.0.0.48

MOXA Inc. Marine Electronics Co.

Page 534: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.30 Electronic Chart Display & Info System ECDIS with backup, and raster chart display syste

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

534 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Northrop Grumman Sperry M arine BV, 118 Burlington Road, New M alden, Surrey, KT3 4NR, United Kingdom (UK).

Electronic Chart Display And Information System (ECDIS) Also tested as Backup ECDIS, and with Raster Chart Display System (RCDS)

VisionMaster FT, WECDlS Hardware component parts of the equipment above are listed in the attached design appraisal document. Software version: - MB 1.0.0

IMO Resolutions: A694(17), MSC191(79), MSC232(82), MSC.36 (63) – 13, MSC.97 (73) - 13 and SN.1/ Circ.266. IEC 60945 (2002) incl. IEC 60945 Corr. 1 (2008) IEC 61162 -1 Ed4.0 (2010) and IEC61162-2 Ed1.0 (1998) IEC 61174 (2008) IEC 62288 Ed. 1.0 (2008)

Expires: 22 June 2019

MED 1400004/ M2

A.1/4.30 ECDIS Vision Master FT, WECDIS Client Server Hardware component parts of the equipment above are listed in the attached design appraisal document. Software version: - MB 1.0.0

Electronic chart display and information system (ECDIS) with backup, and raster chart display system (RCDS) (IEC 61174)

IMO Resolutions: A694(17), MSC191(79), MSC232(82), MSC.36 (63) – 13, MSC.97 (73) - 13 and SN.1/ Circ.266. IEC 60945 (2002) incl. IEC 60945 Corr. 1 (2008) IEC 61162-1 Ed4.0 (2010) and IEC61162-2 Ed1.0 (1998) IEC 61174 (2008) IEC 62288 Ed. 1.0 (2008)

Expires: 20 May 2020

MED 1500005

Page 535: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.30 Electronic Chart Display & Info System ECDIS with backup, and raster chart display syste

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

535 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Praxis Automation Technology BV, Zijldijk 24a, 2352 AB Leiderdorp, Netherlands, The.

Electronic Chart Display & Information System Mega-Guard ECDIS Marine Personal Computer including Mega-Guard Tracker-ball, Operator Keyboard, 19” Flat screen TFT and 23” Flat screen TFT monitors.

A.1/4.30 Electronic chart display and information system (ECDIS)

IMO Resolutions: A.694(17) MSC.191(17) MSC.232(82)

Expires: 30 December 2019

MED 1100003/ M2

Software Version Praxis software release 2014-06-28 update 4 Praxis Integrated Bridge Software release MFD4142 Version 2.00.xxx

IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) IEC 61162-1 (2010) IEC 61162-2 (1998) IEC 61174 (2008 IEC 62288 (2008)

Wuxi Nuorui Electronic Technology Co., Ltd, Room 0901, Building 3,, No. 311, Yanxin Road,, Huishan Economic Development Zone,, Wuxi, Jiangsu Province,, 214174, China, People's Republic of.

ELECTRONIC CHART DISPLAY AND INFORM ATION SYSTEM (ECDIS) RYECDIS-2012L-A Software: NRECDIS, Version: V4.0.2.6

A.1/ 4.30 ELECTRONIC CHART DISPLAY AND INFORMATION SYSTEM (ECDIS) WITH BACKUP , AND RASTER CHART DISPLAY SYSTEM(RCDS)

IEC 60945 (2002) Including IEC 60945 Corrigendum 1: 2008, IEC 61162-1 Ed. 4.0 &61162-2 First Ed.; IEC 61174 (2008); IEC 62288 (2014)

Expires: 24 November 2020

MED 1500030

Page 536: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.33 Track Control System

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

536 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Jinzhou Hangxing Ship Technology Co.Ltd, 1 Huanghai Road, South Railway - Station District, Jinzhou City, Liaoning Province, China, People's Republic of.

Track Control System

DHJ – Software Version 5.0E IEC 60945 (2002) incl. IEC 60945 Corr. 1 (2008) IEC 61162 Series IEC 62065 (2002) IEC 62288 Ed.1.0(2008)

Expires: 14 August 2019

MED 1400011

Kelvin Hughes Ltd, Voltage, M ollison Avenue, Enfield, EN3 7XQ, United Kingdom (UK).

Track Control System Type MantaDigital Widescreen Track Control System (TCS)

Navigation equipment EN: 62065:2014, IEC 62065 Ed.2, IEC 61162 series, IEC 62288, IMO Res. A.694(17), IMO Res. MSC 74(69), IMO Res. MSC 191(79)

Expires: 11 December 2019 This product has been assigned a U.S. Coast Guard Module B number USCG Approval Category 165.112/ EC0038 to note type approval to Module B only as it pertains to obtaining U. S. Coast Guard approval as

MED 1400016

allowed by the “ Corrigendum to Council Decision 2004/ 425/ EC of 21 April 2004 on the conclusion of an Agreement between the European Community and the United States of America on the mutual recognition of certificates of conformity for marine equipment” .

Page 537: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.33 Track Control System

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

537 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Note: For products placed on board U.S. flagged ships there is no declaration of conformity required to meet U.S. Coast Guard requirements.

Northrop Grumman Sperry M arine BV, 118 Burlington Road, New M alden, Surrey, KT3 4NR, United Kingdom (UK).

Track Control System VisionMaster FT , ECDIS with TRACK CONTROL Hardware component parts of the equipment above are listed in the attached design appraisal document. Software version: - 8.0.0

IMO Resolutions: A694(17), MSC191(79), MSC74(69) IEC 60945 (2002) incl. IEC 60945 Corr. 1 (2008) IEC 61162-1 Ed4.0 (2010) and IEC61162-2 Ed1.0 (1998) IEC 62065 Ed2.0 (2014-02) IEC 62288 Ed. 2.0 (2014-07)

Expires: 26 June 2019

MED 1400005/ M2

Page 538: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.34 Radar Equipment CAT 1

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

538 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Northrop Grumman Sperry M arine BV, 118 Burlington Road, New M alden, Surrey, KT3 4NR, United Kingdom (UK).

a) VisionMaster FT, CAT1 34, - Client/ Server Radar Systems b) VisionMaster FT, CAT1C 34, - Client/ Server Chart Radar Systems c) VisionMaster FT, CAT1H 34, - Client/ Server Radar Systems

Shipborne Radar Equipment (IEC 62388 Category 1 & 1C) Radar Equipment for High Speed Craft Applications (IEC62388 Category 1H & 1HC)

IMO Resolutions: A.278 (VIII), A.694 (17), A.823 (19), MSC.191 (79), MSC.192 (79), MSC.36 (63) -13 and MSC.97 (73) – 13. IEC 60945 (2002) incl. IEC 60945 Corr. 1 (2008) IEC 61162-1 Ed4.0 (2010) and IEC61162-2 Ed1.0 (1998) IEC 62288 Ed. 1.0(2008) IEC 62388 Ed. 2.0 (2013)

Expires: 26 June 2019

MED 1400002/ M2

d) VisionMaster FT, CAT1HC 34, - Client/ Server Chart Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document. Software version: - 7.0.0

a) VisionMaster FT, CAT1 34, - Radar Systems b) VisionMaster FT, CAT1C 34, - Chart Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document. Software version: - 5.6.0

Shipborne Radar Equipment (IEC 62388 Category 1 & 1C) Radar Equipment for High Speed Craft Applications (IEC 62388 Category 1H & 1HC)

IMO Resolutions: A278(VIII), A694(17), A823(19), MSC191(79), MSC192(79), MSC.36 (63) – 13 and MSC.97 (73) - 13. IEC 60945 (2002) incl. IEC 60945 Corr. 1 (2008) IEC 61162-1 Ed4.0 (2010) and IEC61162-2 Ed1.0 (1998) IEC 62288 Ed. 1.0 (2008) IEC 62388 Ed. 1.0 (2007)

Expires: 26 June 2019

MED 1400006/ M2

Page 539: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.34 Radar Equipment CAT 1

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

539 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

c) VisionMaster FT Dual Channel, CAT134, - Radar Systems d) VisionMaster FT Dual Channel, CAT1C 34, - Chart Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document. Software version: - 5.6.0

Page 540: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.34 Radar Equipment CAT 1

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

540 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Northrop Grumman Sperry M arine BV ...continued

e) VisionMaster FT, CAT1H 34, - Radar Systems f) VisionMaster FT, CAT1HC 34, - Chart Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document. Software version: - 5.6.0

MED 1400006/ M2

g) VisionMaster FT Dual Channel, CAT1H 34, - Radar Systems h) VisionMaster FT Dual Channel, CAT1HC 34, - Chart Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document. Software version: - 5.6.0

A.1/4.34 RADAR EQUIPM ENT CAT 1 a) VisionMaster FT WECDIS, CAT1 34, - Client/ Server Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document. Software version: - MB 1.0.0

Shipborne Radar Equipment (IEC 62388 Category 1)

IMO Resolutions: A.278 (VIII), A.694 (17), A.823 (19), MSC.191 (79), MSC.192 (79), MSC.36 (63) -13 and MSC.97 (73) – 13. IEC 60945 (2002) incl. IEC 60945 Corr. 1 (2008) IEC 61162-1 Ed4.0 (2010) and IEC61162-2 Ed1.0 (1998) IEC 62288 Ed. 1.0(2008) IEC 62388 Ed. 1.0 (2007)

Expires: 20 May 2020

MED 1500004

Page 541: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.34 Radar Equipment CAT 1

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

541 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

A.1/4.37 RADAR EQUIPM ENT FOR HIGH SPEED CRAFT APPLICATIONS (CAT 1H AND CAT 2H) b) VisionMaster FT WECDIS, CAT1H 34, - Client/ Server Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document.

Shipborne Radar Equipment (IEC 62388 Category 1H)

Software version: - MB 1.0.0

Page 542: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.34 Radar Equipment CAT 1

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

542 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Northrop Grumman Sperry M arine BV ...continued

A.1/4.38(A) RADAR EQUIPM ENT APPROVED WITH A CHART OPTION, NAM ELY: (A) CAT 1C c) VisionMaster FT WECDIS, CAT1C 34, - Client/ Server Chart Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document.

Shipborne Radar Equipment (IEC 62388 Category 1C)

MED 1500004

Software version: - MB 1.0.0

Praxis Automation Technology BV, Zijldijk 24a, 2352 AB Leiderdorp, Netherlands, The.

Radar equipment with automatic radar plotting aid (ARPA) also for high-speed craft Mega-Guard ARPR Radar Marine Personal Computer including Mega-Guard Tracker-ball, Operator Keyboard, 19” Flat screen TFT and 23” Flat screen TFT monitors.

A.1/4.34 Radar Equipment CAT 1 & A.1/ 4.45 Chart facilities for shipborne radar

IMO Resolutions: A.278 (V111) A.694(17) A.823(19) MSC.191(79) MSC.192(79)

Expires: 30 December 2019

MED 1100004/ M2

Software Version Praxis software release 2014-06-28 update 4 Praxis Integrated Bridge Software release MFD4142 Version 2.00.xxx

IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) IEC 61162-1 (2010) IEC 61162-2 (1998) IEC 62288 (2008) IEC 62388 (2007)

Page 543: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.35 Radar equipment CAT 2

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

543 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Northrop Grumman Sperry M arine BV, 118 Burlington Road, New M alden, Surrey, KT3 4NR, United Kingdom (UK).

a) VisionMaster FT, ECAT2 25, - Client/ Server Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document. Software version: - 5.6.0

Shipborne Radar Equipment (IEC 62388 Category 2 & 2C) Radar Equipment for High Speed Craft applications (IEC 62388 Category 2H & 2HC)

IMO Resolutions: A278(VIII), A694(17), MSC191(79) and MSC192(79) IEC 60945 (2002) incl. IEC 60945 Corr. 1 (2008) IEC 61162 -1 Ed4.0 (2010) and IEC61162-2 Ed1.0 (1998) IEC 62288 Ed. 1.0 (2008) IEC 62388 Ed. 1.0 (2007)

Expires: 26 June 2019

MED 1400003/ M2

b) VisionMaster FT, ECAT2C 25, - Client/ Server Chart Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document. Software version: - 5.6.0

c) VisionMaster FT, ECAT2H 25, - Client/ Server Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document. Software version: - 5.6.0

d) VisionMaster FT, ECAT2HC 25, - Client/ Server Chart Radar Systems Hardware component parts of the equipment above are listed in the design appraisal document. Software version: - 5.6.0

Page 544: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.35 Radar equipment CAT 2

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

544 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

a) VisinMaster FT, CAT2 25, - Radar Systems b) VisionMaster FT, ECAT2 25, - Radar Systems c) VisionMaster FT, ECAT2C 25, -Chart Radar Systems d) VisionMaster FT Dual Channel, ECAT2 25, - Radar Systems e) VisionMaster FT Dual Channel, ECAT2C 25, - Chart Radar Systems

Shipborne Radar Equipment (IEC 62388 Category 2 & 2C) Radar Equipment for High Speed Craft applications (IEC 62388 Category 2H & 2HC)

IMO Resolutions: A278(VIII), A694(17), MSC191(79), MSC192(79), MSC.36 (63) – 13 and MSC.97 (73) – 13. IEC 60945 (2002) incl. IEC 60945 Corr. 1 (2008) IEC 61162 -1 Ed4.0 (2010) and IEC61162-2 Ed1.0 (1998) IEC 62288 Ed. 1.0 (2008) IEC 62388 Ed. 1.0 (2007)

Expires: 26 June 2019

MED 1400007/ M2

Page 545: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.35 Radar equipment CAT 2

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

545 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Northrop Grumman Sperry M arine BV ...continued

f) VisionMaster FT, CAT2H 25, - Radar Systems g) VisionMaster FT, ECAT2H 25, - Radar Systems h) VisionMaster FT, ECAT2HC 25, - Chart Radar Systems i) VisionMaster FT Dual Channel, ECAT2H 25, - Radar Systems j) VisionMaster FT Dual Channel, ECAT2HC 25, - Chart Radar Systems

MED 1400007/ M2

Hardware component parts of the equipment above are listed in the attached design appraisal document. Software version: - 5.6.0

Praxis Automation Technology BV, Zijldijk 24a, 2352 AB Leiderdorp, Netherlands, The.

Radar equipment with automatic radar plotting aid (ARPA) also for high-speed craft Mega-Guard ARPR Radar Marine Personal Computer including Mega-Guard Tracker-ball, Operator Keyboard, 19” Flat screen TFT and 23” Flat screen TFT monitors.

A.1/4.35 Radar equipment CAT 2 & A.1/ 4.45 Chart facilities for shipborne radar

IMO Resolutions: A.278 (V111) A.694 (17) A.823 (19) MSC.191 (79) MSC.192 (79)

Expires: 30 December 2019

MED 1100005/ M2

Software Version Praxis software release 2014-06-28 update 4 Praxis Integrated Bridge Software release MFD4142 Version 2.00.xxx

IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) IEC 61162-1 (2010) IEC 61162-2 (1998) IEC 62288 (2008) IEC 62388 (2007)

Page 546: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.49 PILOT LADDER

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

546 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Captain Nemo, 7 Vasiladiou Street, 18540 Piraeus, Greece.

Pilot Ladder PILOT LADDER IMO Resolution A.1045 (27) ISO 799: 2004

Expires: 14 November 2018

MED 1350149

Jiangsu Yuyuan M arine Outfitting Co., Ltd., XingJiang East Road, The Civilian's Economic Developing Zone, Jiangyan Town, Taizhou City, Jiangsu Province, China, People's Republic of.

Pilot Ladder Pilot Ladder IMO Resolution A.1045(27) ISO 799 (2004)

Expires: 27 April 2020

MED 1550101

M arine Safety Supplies Ltd, Unit 2-3, M arine House, Willington Quay, Wallsend, Tyne & Wear, NE28 6SU, United Kingdom (UK).

Ladders Pilot Ladder IMO Resolution A.1045(27), MSC/ Circ. 773, BS ISO 799: 2004

Expires: 16 June 2019

MED 1450127/ M1

M itani Shoten Co. Ltd, 8-19, 1-chome, Kizugawa, Naniwa-ku, Osaka, 556-0027, Japan.

Ladders Pilot Ladder IMO Resolution A.1045 (27) BS ISO 799:2004

Expires: 29 November 2019

MED 1550019

Sea contractor (S) Pte Ltd, 40, Gul Crescent, 629540, Singapore.

SCS Seamaster Pilot Ladder Flat Type PFM

PILOT LADDER IMO Resolution A.1045 (27) ISO 799 (2004)

Expires: 12 July 2020

MED 1550165

Page 547: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.49 PILOT LADDER

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

547 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Seny Ltd, 7 Alexander Dyakovich Str, 9000Varna, Bulgaria.

Pilot Ladder

Pilot Ladder IMO Res. A.1045 (27) ISO 799 (2004)

Expires: 30 March 2021

MED 1650109

Page 548: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.57 Bridge Navigational Watch Alarm System (BNWAS)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

548 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M artek M arine Ltd, Adwick Park, M anvers, Rotherham, South Yorkshire, S63 5AB, United Kingdom (UK).

Navgard

Bridge Navigational Watch Alarm System

EN 60945 (2002) incl. IEC 60945 Corr. 1 (2008) EN 61162 series EN 62288:2008 IEC 62616 (2010)

Expires: 20 May 2018

MED 1300009

Navgard Mini

Bridge Navigational Watch Alarm System

EN 60945 (2002) incl. IEC 60945 Corr. 1 (2008) EN 61162 series EN 62288:2008 IEC 62616 (2010)

Expires: 20 May 2018

MED 1300010

Page 549: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.7 SPEED AND DISTANCE M EASURING EQUIPM ENT (SDM E)

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

549 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ors-Smitt B.V., Vrieslantlaan 6, 3526 AA Utrecht, Netherlands, The.

Type: Dv48S, Dv725, DV96S, Dv144S, D3v48S, D3v72S, D3v96S, D3v144S, D3v144S/ AMP, D3v192S, D3V192S/ AMP, Dv48S/ 66, Dv72S/ 66, Dv96S/ 66, Dv144S/ 66, D3v48S/ 66, D3v72S/ 66, D3v96S/ 66, D3v144S/ 66, D3v144S/ AMP/ 66, D3v192S/ 66, & D3V192S/ AMP/ 66

SPEED INDICATORS IEC 61023 (2007) IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008)

Expires: 20 July 2020

MED 1050349/ M4

M ors-Smitt B.V., Vrieslantlaan 6, Utrecht, 3502KA, Netherlands, The.

Type SXv96/ A-1, SXv96/ CAN, SXv96/ 66/ A-1, SXv96/ 66/ CAN

SPEED INDICATOR IEC 61023 (2007) IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) IEC 62288 (2008)

Expires: 4 July 2018

MED 1300014

Page 550: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment Product: M ED/4.9 RATE-OF-TURN INDICATOR

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

550 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

M ors-Smitt B.V., Vrieslantlaan 6, 3526 AA Utrecht, Netherlands, The.

Rudder Angle Indicator – Type D3v144S, D3v144S/ AMP, D3v192S, D3V192S/ AMP, D3v144S/ 66, D3v144S/ AMP/ 66, D3v192S/ 66, & D3V192S/ AMP/ 66

Measuring Instruments and CT’s IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008) ISO 20672:2007

Expires: 27 November 2019 The indicators are only to be installed on board w ith a: 1) MED certified driving unit and transmitter w ith a suitable junction box; or 2) MED certified revolution sensor and signal converter.

MED 1050348/ M4

Page 551: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

551 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

CANTALUPI SRL, Via M ichele Coppino 371, 55049 Viareggio (LU), I taly.

LED Navigation lights for power-driven vessels (> 20m) Rated power supply: 24V DC

EN 14744 (2005) including AC (2006) IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008)

Expires: 26 May 2020 1. 360° Green and 360° Amber CANTALUPI LED Navigation lights may only be fitted to vessels less than 50 metres as per COLREGs 72 Rule 22 as amended.

MED 1550130/ M1

Read as one Table Read as one Table

Stern Light Single Stern Light Double Towing Light Single Towing Light Double Starboard Light Single Starboard Light Double

Type code: Visibility range CE NL S 01 >3 NM (135°) CE NL D 01 >3 NM (135°) CE NL S 02 >3 NM (135°) CE NL D 02 >3 NM (135°) CE NL S 03 >3 NM (112.5°) CE NL D 03 >3 NM (112.5°)

2. The navigation light controller does not form a part of this design appraisal document. CANTALUPI LED Navigation lights on board vessels are to be used in conjunction w ith

Port Light Single Port Light Double Masthead Light 5NM Single Masthead Light 5NM Double Combined Masthead Light 6NM Single Combined Masthead Light 6NM Double Anchor Light Single Anchor Light Double

CE NL S 04 >3 NM (112.5°) CE NL D 04 >3 NM (112.5°) CE NL S 05 >5 NM (225°) CE NL D 05 >5 NM (225°) CE NL CS 05 05 >6 NM (225°) CE NL CD 05 05 >6 NM (225°) CE NL S 06 >3 NM (360°) CE NL D 06 >3 NM (360°)

appropriate navigation light controller complied w ith IMO Resolution MSC.253(83). 3. CANTALUPI LED Navigation lights comply w ith Section 4.3.1 of IMO Resolution MSC.253(83).

Page 552: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

552 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

NUC Light Single NUC Light Double 360° Green Light Single 360° Green Light Double 360°Amber Light Single 360°Amber Light Double 180° RED Light Single 180° RED Light Double

CE NL S 07 >3 NM (360°) CE NL D 07 >3 NM (360°) CE NL S 08 >2 NM (360°) CE NL D 08 >2 NM (360°) CE NL S 09 >2 NM (360°) CE NL D 09 >2 NM (360°) CE NL S 10 >3 NM (180°) CE NL D 10 >3 NM (180°)

STANDARD Lights can be assembled into various configurations of COMBINED Lights (see Section 3 of User Manual UM.00001.001).

Page 553: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

553 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

CANTALUPI SRL ...continued

Different materials of the housing and finishing are identified by adding these letters to the type code: BA = BLACK ALUMINIUM GA = GREY ALUMINIUM SS = STAINLESS STEEL

MED 1550130/ M1

CURRENT SCIENTIFIC CORPORATION, 2933 M urray Street, Port M oody, BC, V3H 1X3, Canada.

Night Vision Equipment Type: Night Navigator™HSC

ISO 16273:2003, IEC 60945 (2002) Incl. IEC 60945 Corr. 1 (2008), IEC 62288 Ed. 1.0 (2008) MSC.36(63)-(1994 HSC Code)13 MSC.94(72) MSC.97(73)-(2000HSC Code)13 MSC.191(79)

Expires: 1 June 2020

MED 1500007

Daeyang Electric Co. Ltd., 245, Jangpyeong-ro,, Saha-gu, Busan, Korea, Republic of.

Single and Duplex LED navigation lights – Type: ” A2L-SM” Range and “ A2L-DM” Range

Navigation Lights 72 COLREGs – International Regulations for Preventing Collisions at Sea amended by IMO Resolution A.1004 (25) Annex I/ 14. EN60945 (2002) - EN14744 (2005) including AC (2006).

Expires: 19 April 2017

MED 1250068

Page 554: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

554 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Ibuki Kogyo Co., Ltd, 7-28 Takadono 1-Chome, Asahi-Ku, Osaka, 535-0031, Japan.

Single type: Masthead light Side light Side light Stern Light All round Light All round Light All round Light Towing Light Manoeuvring Light

Type code: NLLM-1W NLLG-1R NLLG-1G NLLS-1W NLLA-1W NLLA-1R NLLA-1G NLLT-1Y NLLA-ML

Visibility range (nautical miles): 6 NM (225°) 3 NM (112,5°) 3 NM (112,5°) 3 NM (135°) 3 NM (360°) 3 NM (360°) 3 NM (360°) 3 NM (135°)

LED Navigation lights for power-driven vessels (> 50m ) Rated power supply: 100/ 220V AC, 24V DC Ingress protection: IP56

EN 14744 (2005) including AC (2006) IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008)

1. NLL series LED Navigation lights safe compass distance is 0,2m. 2. The navigation light controller does not form a part of this design appraisal document. NLL series LED Navigation lights on board vessels are to be used in conjunction w ith appropriate navigation light controller

MED 1700004

Double type: Masthead Light Side Light Side Light Stern Light All round Light All round Light Flashing lights: Flashing Light

NLLM-1WD NLLG-1RD NLLG-1GD NLLS-1WD NLLA-1WD NLLA-1RD NLLF-1R (130 pulse/ min) NLLF-2R (190 pulse/ min)

5 NM (360°) 6 NM (225°) 3 NM (112,5°) 3 NM (112,5°) 3 NM (135°) 3 NM (360°) 3 NM (360°) 2 NM (360°)

complied w ith IMO Resolution MSC.253(83). 3. NLL series LED Navigation lights comply w ith Section 4.3.1 of IMO Resolution MSC.253(83).

Page 555: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

555 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Ibuki Kogyo Co., Ltd ...continued

Flashing Light Flashing Light

NLLF-1G (130 pulse/ min) 2 NM (360°) 2 NM (360°)

MED 1700004

Manually operated all-round white manoeuvring light with interlock to ship’s whistle for automatic operation- Type: “ M L”

NAVIGATION LIGHTS The Convention on the International Regulations for Preventing Collisions at Sea 1972 (COLREG) as amended EN60945:2002 EN14744:2005

Expires: 20 October 2021

MED 1750007

Lopolight ApS, Ved Klaedebo 12B, Hoersholm, DK-2970, Denmark.

Single and Double LED Masthead Navigation Lights – Type: “P/N 300-036/300-037/300-038/300-039/300-138/300-139”.

NAVIGATION LIGHTS 72 COLREGs – International Regulations for Preventing Collisions at Sea amended by IMO Resolution A.1004 (25) Annex I/ 14. EN60945 (2002) including Corrigendum 1 (2008) - EN14744 (2005) including AC (2006).

Expires: 24 July 2018

MED 1350099

Single and Double LED Navigation Lights, Lopolight Part Numbers:

NAVIGATION LIGHTS EN60945 (2002) including IEC 60945 Corrigendum 1 (2008) and EN14744 (2005) including AC (2006)

Expires: 9 June 2021

MED 1600011

“100-001, 100-002, 100-003, 100-004, 100-005, 100-009 200-003, 200-004, 200-005, 200-007, 200-010, 200-011, 200-012, 200-013, 200-014, 200-015, 200-016, 200-018, 200-020, 200-021, 200-024, 200-030 300-001, 300-002, 300-005, 300-006, 300-008, 300-009, 300-101, 300-102, 300-105ST, 300-106, 300-108ST, 300-109ST, 300-112, 300-114 and 300-115”

Page 556: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

556 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Oxley Development Ltd, Priory Park, Ulverston, Cumbria, LA12 9QG, United Kingdom (UK).

NAVIGATION LIGHTS LED Masthead light suitable for vessels of 50 m or more in length Type: “ OXLELEDCP40982.WE” .

EN 14744 (2005) including AC (2006), EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008)

Expires: 13 November 2017

MED 1200014

NAVIGATION LIGHTS LED Sidelights suitable for vessels of 50 m or more in length Types: “ OXLELEDCP40983.RD and OXLELEDCP40983.GN” .

EN 14744 (2005) including AC (2006), EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008)

Expires: 13 November 2017

MED 1200015

NAVIGATION LIGHTS LED Stern light suitable for vessels of 50 m or more in length Type: “ OXLELEDCP40984.WE” .

EN 14744 (2005) including AC (2006), EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008)

Expires: 13 November 2017

MED 1200016

Page 557: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

557 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Oxley Development Ltd ...continued

NAVIGATION LIGHTS LED Anchor light suitable for vessels of 50 m or more in length Type: “ OXLELEDCP40985.WE” .

EN 14744 (2005) including AC (2006), EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008)

Expires: 13 November 2017

MED 1200017

NAVIGATION LIGHTS LED NUC/ RAM/ CBD light suitable for vessels of 50 m or more in length Type: “ OXLELEDCP40986/ 225.RD” and “ OXLELEDCP40986/ 140.RD” .

EN 14744 (2005) including AC (2006), EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008)

Expires: 13 November 2017

MED 1200018

NAVIGATION LIGHTS LED NUC/ RAM/ CBD light suitable for vessels of 50 m or more in length Type: “ OXLELEDCP40987/ 225.WR” and “ OXLELEDCP40987/ 140.WR” .

EN 14744 (2005) including AC (2006), EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008)

Expires: 13 November 2017

MED 1200019

NAVIGATION LIGHTS LED Manoeuvring and Warning Signal light suitable for vessels of 50 m or more in length Type: “ OXLELEDCP40990.WE” .

EN 14744 (2005) including AC (2006), EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008)

Expires: 13 November 2017

MED 1200020

Read as one Table

LED Navigation lights for power-driven vessels (> 50m ) Rated power supply: 24V DC Ingress protection: IP67 Read as one Table

EN 14744 (2005) including AC (2006) IEC 60945 (2002) including IEC 60945 Corrigendum 1 (2008)

Expires: 3 April 2021 1. The navigation light controller does not form a part of this appraisal. The subject LED Navigation lights on board vessels are to

MED 1600006

Page 558: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

558 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

MASTHEAD LIGHT (SINGLE), WHITE MASTHEAD LIGHT (DOUBLE), WHITE STARBOARD LIGHT (SINGLE), GREEN STARBOARD LIGHT (DOUBLE), GREEN

Type code: Visibility range (nautical miles): OXLELEDCP44510.WE 5 NM (225°) OXLELEDCP44510.WE2 5 NM (225°) OXLELEDCP44511.GN 3 NM (112.5°) OXLELEDCP44511.GN2 3 NM (112.5°)

be used in conjunction w ith an appropriate navigation light controller complying w ith IMO Resolution MSC.253(83). 2. Subject LED Navigation lights are found to comply w ith Section 4.3.1 of IMO Resolution MSC.253(83).

Page 559: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

559 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Oxley Development Ltd ...continued

PORT LIGHT (SINGLE), RED PORT LIGHT (DOUBLE), RED STERN LIGHT (SINGLE), WHITE STERN LIGHT (DOUBLE), WHITE DEEP DRAFT LIGHT (SINGLE), RED

OXLELEDCP44511.RD 3 NM (112.5°) OXLELEDCP44511.RD2 3 NM (112.5°) OXLELEDCP44513.WE 3 NM (135°) OXLELEDCP44513.WE2 3 NM (135°) OXLELEDCP44518.RD 3 NM (360°)

MED 1600006

NUC LIGHT (DOUBLE), RED RIAM LIGHT (SINGLE), WHITE ANCHOR LIGHT (SINGLE), WHITE ANCHOR LIGHT (DOUBLE), WHITE

OXLELEDCP44518.RD2 3 NM (360°) OXLELEDCP44518.WE 3 NM (360°) OXLELEDCP44544.WE 3 NM (360°) OXLELEDCP44544.WE2 3 NM (360°)

Shengan M arine Co., Ltd., No. 2, Chang-Chuen St., Siaokang Dist. 81246, Kaohsiung, Taiwan.

Fixed Daylight Signalling Lamp Model – Type:”SGNO-10SN & SGNO-10SHN”.

DAYLIGHT SIGNALLING LAM P EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008) and ISO 25861 (2007).

Expires: 12 March 2019

MED 1450056

Page 560: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

560 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Electric sternlight – Type: ” NLSL-11” (single) and “ NLSL-22” (duplex) Electric port sidelight – Type: “ NLRL-11” (single) and “ NLRL-22” (duplex) Electric starboard sidelight – Type: “ NLGL-11” (single) and “ NLGL-22” (duplex) Electric towing light – Type: “ NLTL-11” (single) and “ NLTL-22” (duplex) Electric all-round light – Type: “ SLWL-11/ 22” , “ SLRL-11/ 22” , “ SLGL-11/ 22” ,

NAVIGATION LIGHT 72 COLREGs – International Regulations for Preventing Collisions at Sea amended by IMO Resolution A.1004 (25) Annex I/ 14. EN60945 (2202) including Corrigendum 1 (2008) – EN14744 (2005) including AC (2006

Expires: 10 August 2020

MED 1550201

SLYL-11/ 22” (single & duplex) Electric manoeuvring light (single tier) – Type: “ SLML-11” Electric masthead light – Type: “ NLML-11” (single) and “ NLML-22” (duplex)

Page 561: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

561 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shengan M arine Co., Ltd. ...continued

Conventional and LED Navigation Lights Types - Conventional SLWRL-22 A ll Round Light, Double Tier, White-Red SLWGL-22 A ll Round Light, Double Tier, White-Green SLRWL-22 A ll Round Light, Double Tier, Red-White SLRGL-22 A ll Round Light, Double Tier, Red-Green SLGRL-22 A ll Round Light, Double Tier, Green-Red SLGWL-22 A ll Round Light, Double Tier, Green-White SLWL-22S 180° Light, Double Tier, White-White

NAVIGATION LIGHT (Conventional & LED)

EN14744 (2005) including AC (2006) EN60945 (2002) including Corrigendum 1 (2008)

Expires: 22 June 2021

MED 1600012

Page 562: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

562 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

SLRL-22S 180° Light, Double Tier, Red-Red SLGL-22S 180° Light, Double Tier, Green-Green SLWRL-22S 180° Light, Double Tier, White-Red SLWGL-22S 180° Light, Double Tier, White-Green SLRWL-22S 180° Light, Double Tier, Red-White SLRGL-22S 180° Light, Double Tier, Red-Green SLGRL-22S 180° Light, Double Tier, Green-Red SLGWL-22S 180° Light, Double Tier, Green-White SLWL-11S 180° Light, Single Tier, White SLRL-11S 180° Light, Single Tier, Red

Page 563: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

563 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shengan M arine Co., Ltd. ...continued

SLGL-11S 180° Light, Single Tier, Green NLSRL-11 135° Light, Single Tier, Red NLSGL-11 135° Light, Single Tier, Green Types - LED SLWRL-22L A ll Round Light, Double Tier, White-Red SLWGL-22L A ll Round Light, Double Tier, White-Green SLRGL-22L A ll Round Light, Double Tier, Red-Green SLGRL-22L A ll Round Light, Double Tier, Green-Red SLGWL-22L A ll Round Light, Double Tier, Green-White

MED 1600012

Page 564: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

564 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

SLWL-22LS 180° Light, Double Tier, White-White SLRL-22LS 180° Light, Double Tier, Red-Red SLGL-22LS 180° Light, Double Tier, Green-Green SLWRL-22LS 180° Light, Double Tier, White-Red SLWGL-22LS 180° Light, Double Tier, White-Green SLRWL-22LS 180° Light, Double Tier, Red-White SLRGL-22LS 180° Light, Double Tier, Red-Green SLGRL-22LS 180° Light, Double Tier, Green-Red SLGWL-22LS 180° Light, Double Tier, Green-White SLWL-11LS 180° Light, Single Tier, White

Page 565: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

565 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shengan M arine Co., Ltd. ...continued

SLRL-11LS 180° Light, Single Tier, Red SLGL-11LS 180° Light, Single Tier, Green NLSRL-11L 135° Light, Single Tier, Red NLSGL-11L 135° Light, Single Tier, Green

MED 1600012

Shengan M arine Co.Ltd., 2 Chang Chun Street, Siaokang, Kaohsiung 81246, Taiwan.

Single and Double LED Navigation Lights – Type: ”NLM L-11L & NLM L-22L” Range.

NAVIGATION LIGHTS 72 COLREGs – International Regulations for Preventing Collisions at Sea amended by IMO Resolution A.1004 (25) Annex I/ 14. EN60945 (2002) including Corrigendum 1 (2008) and EN14744 (2005) including AC (2006)

Expires: 22 October 2018

MED 1350134

Portable Daylight Signalling Lamp Model – Type:”SGSP-24A”.

DAYLIGHT SIGNALLING LAM P EN 60945 (2002) including IEC 60945 Corrigendum 1 (2008) and ISO 25861 (2007).

Expires: 5 November 2018

MED 1350146

NAVIGATION LIGHTS Electric sternlight suitable for vessels of 50 m or more in length – Type: “ NLSL-11” (single) and “ NLSL-22” (duplex)

EN 14744 (2005), EN 60945 (2002) Expires: 4 August 2019

MED 1450228/ M1

Navigation Lights Electric port sidelight suitable for vessels of 50 m or more in length – Type: “ NLRL-11” (single) and “ NLRL-22” (duplex)

EN 14744 (2005), EN 60945 (2002) Expires: 4 August 2019

MED 1450229/ M1

Page 566: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

566 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Navigation Lights Electric starboard sidelight suitable for vessels of 50 m or more in length – Type: “ NLGL-11” (single) and “ NLGL-22” (duplex)

EN 14744 (2005), EN 60945 (2002) Expires: 4 August 2019

MED 1450230/ M1

Navigation Lights

Electric towing light suitable for vessels of 50 m or more in length – Type: “ NLTL-11” (single) and “ NLTL-22” (duplex)

EN 14744 (2005), EN 60945 (2002) Expires: 4 August 2019

MED 1450231/ M1

Navigation Lights Electric all-round light suitable for vessels of 50 m or more in length light – Type: “ SLWL-11” , “ SLRL-11” , “ SLGL-11” , “ SLYL-11” (single) and “ SLWL-22” , “ SLRL-22” , “ SLGL-22” , “ SLYL-22” (duplex)

EN 14744 (2005), EN 60945 (2002) Expires: 4 August 2019

MED 1450232/ M1

Page 567: Subject: Equipment under SOLAS Chapter II -1. Construct ion … · 2017-05-11 · Subject: Equipment under SOLAS Chapter II -1. Construct ion Product: M ED/8.1 Water Level Detectors

Subject: Navigation equipment COLREG 72 Product: M ED/6.1 NAVIGATION LIGHTS

Producer Product and Type Details of Approval Specified Standard Remarks Cert. No.

567 LLOYD'S REGISTER, 2017 NOTICE AND TERMS OF USE Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause

'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

http://www.cdlive.lr.org/information/

Shengan M arine Co.Ltd. ...continued

Navigation Lights Electric manoeuvring light (single tier) – Type: “ SLML-11”

EN 14744 (2005), EN 60945 (2002) Expires: 4 August 2019

MED 1450233/ M1

Navigation Lights

Electric masthead light suitable for vessels of 50 m or more in length – Type: “ NLML-11” (single) and “ NLML-22” (duplex)

EN 14744 (2005), EN 60945(2002) Expires: 4 August 2019

MED 1450234/ M1