SUB-STATIONS
![Page 2: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/2.jpg)
INTRODUCTION
The assembly of apparatus used to change some characteristic(e.g. Voltage, a.c to d.c, frequency, power factor etc) of electric supply is called a sub-station
![Page 3: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/3.jpg)
SITE SELECTION …..
• It should be located at the centre of gravity of load
• It should be easily operated and maintained
• It should provide safe and reliable arrangement
• It should involve minimum capital cost
![Page 4: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/4.jpg)
CLASSIFICATION OF SUB-STATIONS
Sub-stations
Service requirement
Constructionalfeatures
![Page 5: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/5.jpg)
ACCORDING TO SERVICE REQUIREMENT
Transformer sub stations : these are used to change the voltage levels of supply
switching sub stations: they simply perfome switching operations of power lines
Power factor sub stations: they improve the power factor of the system by using synchronous condensers
Frequency sub stations: those sub stations which change supply frequency
Converting sub stations: those sub stations which change a.c. power to d.c. power
Industrial sub stations: those sub stations which supply power to industries
Substations are classified as……..
![Page 6: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/6.jpg)
TRANSFORMER SUB-STATIONSTransformer substations are classified into 4 types these are……..
step up substation: the generation voltage is stepped up to high voltage
Primary grid substation: here the voltage level is step down to 66kv from 220kv for secondary transmission
Secondary substation: the voltage level is further step down to 11kv and these substations are generally outdoor type
Distribution substation: the electric power from 11kv lines is delivered to distribution substation. These are generally located near consumer localities…
![Page 7: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/7.jpg)
ACCORDING TO CONSTRUCTIONAL FEATURES
According to constructional features, the sub stations are classified as:
Indoor sub station: these substations can be installed for voltages up to 11kv
Outdoor sub station: for voltages beyond 66kv these type of sub stations can be installed
Underground sub stations: in thickly populated areas, the space available is less so we install these type of substations
Pole mounted substations: this is an outdoor substation with equipment installed overhead on h-pole or 4 pole structure
![Page 8: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/8.jpg)
INDOOR SUBSTATION…..
![Page 9: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/9.jpg)
BLOCK DIAGRAM>>>>>>
![Page 10: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/10.jpg)
pole mounted substationIt is a schematic view of pole mounted substation……
![Page 11: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/11.jpg)
POLE MOUNTED SUBSTATION……
![Page 12: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/12.jpg)
UNDERGROUND SUBSTATION……While designing a underground sub station the following points are to be followed:
the size of substation should be minimum
There should be reasonable access for both equipment
There should be provision for emergency lights and protection against fire
There should be good ventilation
the transformers,switches,fuses should be air cooled to avoid bringing oil into premises
![Page 13: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/13.jpg)
![Page 14: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/14.jpg)
Schematic view………
![Page 15: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/15.jpg)
SYMBOLS FOR EQUIPMENT IN SUB STATIONS
![Page 16: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/16.jpg)
![Page 17: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/17.jpg)
EQUIPMENT IN A TRANSFORMER SUB STATION
BUS BARS: various incoming and out going circuits are connected to bus bars.busbars receive power from incoming circuits and deliver power to out going circuits.
.
Electric substations are the part of power systems and used for transferring power from generating points to load centres.some of important components are…
![Page 18: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/18.jpg)
INSULATORS: insulators serve two purposes 1) they support conductors(busbars) 2) confine the current to the conductors most commonly used material for manufacture of insulators is porcelain.
![Page 19: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/19.jpg)
ISOLATING SWITCHES: in sub stations it is often desired to disconnect a part of system for general maintenance and repairs. this is accomplished by an isolating switch or isolators.
![Page 20: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/20.jpg)
Circuit breaker: circuit breaker is used for switching during normal and abnormal conditions. it is used to interrupt short circuit currents .there are many types of circuit breakers.. 1) air blast circuit breaker. 2) oil circuit breaker 3) sf6 circuit breaker
![Page 21: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/21.jpg)
power transformers: these are used to step down or step up a.c. voltages and to transfer electrical power from one voltage level to another.
![Page 22: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/22.jpg)
Current transformers: current transformer in essentially a step up transformer which steps down the current to a known ratio.
![Page 23: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/23.jpg)
voltage transformer: it is essentially a step down transformer and steps down the voltage to a known ratio.
![Page 24: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/24.jpg)
metering and indicating instruments: there are several metering and indicating instruments installed in a sub station to maintain watch over the circuit quantities.
in addition to these there may be following equipment in a substation. 1) fuses 2) carrier current equipment 3) sub station auxiliary supplies
![Page 25: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/25.jpg)
BUS BAR ARRANGEMENTS IN A SUBSTATION
Single bus bar system…
![Page 26: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/26.jpg)
Duplicate bus bar system…..
![Page 27: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/27.jpg)
Key diagram of 66/11kv substation
![Page 28: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/28.jpg)
Key diagram of 11/440v indoor substation
![Page 29: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/29.jpg)
GAS INSULATED SUBSTATION
![Page 30: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/30.jpg)
INTRODUCTION…
Gas Insulated substations use sulphur hexa fluoride(SF6) gas which has superior dielectric properties. Gas insulated substations are used where there is space for providing the substation is expensive in large cities and towns
![Page 31: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/31.jpg)
TYPES OF GAS INSULATED SUBSTATIONSGas insulated substations are classified according
to the type of configurations as………..
isolated phase module
3-phase common modules
hybrid modules
Compact modules
Highly integrated systems
![Page 32: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/32.jpg)
Isolated-phase module
The individual circuit elements such as a pole of a circuit breaker, a single pole isolator, one phase assembly of a current transformer etc..are connected together forms an isolated phase GIS module.
![Page 33: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/33.jpg)
THREE PHASE COMMON MODULE
In this type of module a three phase bay is assembled using the desired number of three phase elements. This reduces the total number of enclosures to one third.
![Page 34: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/34.jpg)
HYBRID MODULES
It is the combination of isolated phase and three phase common elements is used to achieve an optimal solution. Hybrid GIS technology has gained popularity, specially in the medium and low voltage range
![Page 35: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/35.jpg)
COMPACT MODULE
Compact GIS systems are essentially three phase common systems in which the elements such as three phase circuit breaker, current transformer etc…. Are placed
![Page 36: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/36.jpg)
HIGHLY INTEGRATED SYSTEM
These are used in outdoor substations .highly integrated substations are ready to install substations.
![Page 37: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/37.jpg)
SINGLE LINE DIAGRAM
![Page 38: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/38.jpg)
BUS BARS
The high voltage conductor made up of copper or aluminum is centrally placed in a tabular metal enclosure. In isolated phase GIS ,coaxial bus bar are common
![Page 39: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/39.jpg)
Constructional aspects of GIS……..
The main parts of GIS are…….
gas circuit seals and gaskets disconnectors earth switchCircuit breakerCurrent transformerPlug in jointsEnclosureExpansion joints
![Page 40: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/40.jpg)
![Page 41: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/41.jpg)
Gas circuit : gas circuit has to maintain the dual purpose (i.e. arc interruption and insulation). Gas circuit should maintain the pressure throughout its life period so there should be no leakages
SEALS AND GASKETS : seals and gaskets are used to capture the SF6 gas lekages.these are manufactured with nitrile rubber and viton. These serves sealing purpose
![Page 42: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/42.jpg)
Disconnectors…..Disconnectors or isolators are used for electrical isolation of circuit parts.They are slow acting and operating at off load.Disconnectors must be carefully designed and tested to be able to break small charging current without generating too higher over voltage.
![Page 43: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/43.jpg)
Circuit Breakers…….
Circuit breaker is a metal clad and uses SF6 gas for the purpose of insulation and fault interruption. The circuit breaker is directly connected to either current transformers or isolators
![Page 44: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/44.jpg)
![Page 45: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/45.jpg)
Earthing switch……
fast earth switch: these are used to protect the circuit connected current transformer, voltage transformer
Maintenance earth switch: these are used for grounding the high voltage conductors during maintenance
![Page 46: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/46.jpg)
PLUG IN JOINTS: these are designed in such a way that they can carry rated full load current uninterruptedly and can carry heavy transient currents types of plug in joints areStatic jointsQuasi static joints
![Page 47: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/47.jpg)
MAINTENANCE AND INSTALLATION
S.NO 145KV 170KV 245KV
1 Bay width (m)
1.5 2.0 2.0
2 Bay depth 3.3 3.35 3.4
3 Bay height 3.2 3.4 3.4
4 Floor area(sq.m)
4.95 6.7 6.8
5 Volume 15.84 22.78 23.12
6 Weight 3800 5000 5700
![Page 48: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/48.jpg)
Advantages of GIS….
GIS have no risk for fire and explosion due to leakage of oil.They generate no noise and have no radio interference.The maintainence of GIS is free.It offers solutions, -Industrial areas where space and pollution problems . -Mountain areas where ice and snow are major problems.
![Page 49: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/49.jpg)
Disadvantages of GIS…….
Gas insulations tend to be much more expensive than air insulated installations with the same ratings.Care should be taken that no dust particles enter into the live compartments which results in flash over.When fault occurs internally the diagnosis of the fault and rectifying takes very long time.
![Page 50: Sub stations-air insulated substations](https://reader036.vdocuments.us/reader036/viewer/2022081505/554a04e6b4c905557a8b533b/html5/thumbnails/50.jpg)
COMPARISON OF AIR INSULATED SUBSTATIONS AND GAS INSULATED SUBSTATIONS