studio adaptor - hitachi · pdf file1 rear panel of the sa-1000 operation ca-hf1000 ret1/2 sel...

17
Studio adaptor SA-1000 Operation manual <Tentative>

Upload: hoangminh

Post on 16-Mar-2018

219 views

Category:

Documents


2 download

TRANSCRIPT

Studio adaptor SA-1000

Operation manual

<Tentative>

1

Rear panel of the SA-1000 operation

CA-HF1000 RET1/2 SEL switch

Extender LED Light when lens Extender x0.8 is on

POWER Lamp Light when camera Head power is supplied

Camera menu switch

Call button

Lens Extender switch Light when Extender is on

Front tally switch Selects high/low/off

ND/CC select switch

Viewfinder video select switches select R,G,B

Return Select switch RET1,2

Viewfinder display panel CS1/2

Lights when ING is on. Memory switch

CROSS,BOX1,BOX2 is memory Lights when ING is on. CROSS,BOX1,BOX2 switch

CROSS,BOX1,BOX2 control Level volume

Graticule of display level control Position H,V volume

Adjustment of position Size H,V volume Adjustment of size

2

Video switches for the View Finder (R/G/B) operation

R/G/B view finder video can be selected by R,G and B switches in the rear panel.

The selected switch’ s LED light and display video in the view finder.

Return signal selection switch operation

Return video signal can be selected by the Return Box, the rear panel of the Buildup Adapter and the lens return switch.

From the Rear panel of the buildup Adapter

Return signal Operational description

CA-HF1000 RET1 The RET SEL switch is set to CH1 and the RET1 switch

of Buildup adapter is pushed.

RET CH1

CA-HF1000 RET2 The RET SEL switch is set to CH1 and the RET2 switch

of Buildup adapter is pushed.

CA-HF1000 RET1 The RET SEL switch is set to CH2 and the RET1 switch

of Buildup adapter is pushed.

RET CH2

CA-HF1000 RET2 The RET SEL switch is set to CH2 and the RET2 switch

of Buildup adapter is pushed.

CA-HF1000 RET1 The RET SEL switch is set to CH3 and the RET1 switch

of Buildup adapter is pushed.

RET CH3

CA-HF1000 RET2 The RET SEL switch is set to CH3 and the RET2 switch

of Buildup adapter is pushed.

CA-HF1000 RET1 The RET SEL switch is set to CH4 and the RET1 switch

of Buildup adapter is pushed.

RET CH4

CA-HF1000 RET2 The RET SEL switch is set to CH4 and the RET2 switch

of Buildup adapter is pushed.

Electric Filter operation

The camera head has ND and CC filters. The selected switch’ s LED light. The ND and CC filter in the rear panel of the Buildup Adapter normally does not work unless given control from the RCU or SCU

(CTLHEAD or FILTER HEAD). < HD CAMERA SK-HD1000 >

CAP 1 2 3 4 - ND Filer position Filter display CAP CLEAR CROSS 1/16ND 1/64ND

A B C D E F CC Filer position Filter display 3200K 4300K 5600K 6300K 8000K -

3

EXTENDER SWITCH OPERATION

THE X2 extender can be changed with the EXTENDER selection switch in the rear panel of the buildup Adapter. (This Extender switch can not control the x2 extender for the portable lens.) The LED light when the x2 extender “ ON” .

FRONT TALLY SEL OPERATION

This has three modes. H : High mode for Red Tally L : Low mode for Red Tally

OFF : No red Tally (Optional tally in the studio type lens has only ON or OFF mode. The tally light at H & L mode.)

FUNC/UP/DOWN/RIGHT/LEFT SWITCH OPERATION

Press the FUNC switch then menu display in the viewfinder. Function in the menu can be selected with the UP/DOWN/RIGH/LEFT switch.

* The camera head menu in addition to the viewfinder menu can be opened when CTL HEAD and it is

self-controlled.

CALL operation

Press the CALL switch, the HEAD, VF, CCU, RU and the SU RED TALLY LED turn on.

4

SA CS-1/CS-2 display switch operation

Press the CS-1/CS-2 switch and VF marker1/2, Focus IND can be changed. Also VF maker level can be adjusted NEGA toPOSI by the LEVEL variable register (VR). The CS-1/CS-2 LED lights when the CS-1/CS-2 is ON.

・SA CS-1/2 Select

・MARKER 1/2 Select

・FOCUS IND

Press the FOCUS IND and the LED light and display 0 to 100 character in the top right of the VF.

CROSS/BOX1/BOXn 2/MEMORY switch operatio

Press the Cross, BOX1 or BOX2 individual switches, then previous position & size memory data are displayed in the view finder. Selected switch LED lights and display level can be adjusted by the LEVEL VR. Individual POSI and SIZE for H/V can be adjusted by the rotary ENC. Adjustable display is last selected data in the CROSS, BOX1 or BOX2. And also adjusted data can be stored to the memory by pressing the Memory switch. The Memory switch LED blinking lights during storing data.

TOP MENU

VF :

■ CUSTOM SW :

CUSTOM SW MENU

CS-1 SW : ZEBRA CA-CS SW : ---------

LENS VTR SW : TALK SA CS-1 SW : MARKER1 SA CS-2 SW : MARKER2

MARKER1 MARKER2 FOCUS IND Select

TOP MENU

VF :

CUSTOM SW :

VF MENU

VF OUT SEL : COLOR VF DETAIL :

VF MARKER : SIDE PANEL : VF DISPLAY : VF ZEBRA :

VF MARKER

USER SEL : USER 1 MARKER1 SEL :

MARKER2 SEL : OTHER SET :

MARKER1 SEL

CENTER MARK : ON SAFETY MARK : ON

SIDE 4:3 : OFF 13:9 : OFF

14:9 : OFF 15:9 : OFF

5

LED INDICATERPOWER

LED The Power LED lights when the camera head power is supplied.

x0.8 LED

The 0.8 LED lights when the lens extender in.

Move the lever to the Lock positionand place the camera on the mount base.

Move the lever to rock the mount base . Adjust and fit of the camera in the bayonetmount with holding the rear side of thecamera, and then press down the lock lever.

Move each of the levers and tothe Unlock position.While pushing the slide release pin ,slide the camera into the bayonet mount.

A

A

B

D

D

C

1 2

5 6 Camera attachment completed

3 4

A

Place the levers and in the Lock

position to stop the vertical and horizontal

movements of the camera, respectively.

Connect the viewfinder to camera.A D

C

A D B

CAMERA ATTACHMENT

STUDIO ADAPTER SA-1000(Box type lens mount)

Remove the view finder from the camera. Push the bayonet mount lever upwardto unlock the camera.

Pull the camera rearward to remove itfrom the bayonet mount.

Pushing the release button .Move the lever to unlock the mount base.

E

1 2

3 4

Remove the camera from the mount base.

E

Camera removal completed

CAMERA REMOVAL

STUDIO ADAPTER SA-1000(Box type lens mount)

Align the lugs of the build-up adapter with the lugs of the handy plate.Push the lower part of the handy plate.

Secure the plate by locking the rock screw.(M5 Hexagon wrench)

F G

A

D

2 3 4 Removal completed

Attachment completed

G

Remove the camera lens, and then move

the camera body rearward.

Remove the camera from the mount base. Loose the rock screw. Lightly tap the upper part of the mounting.

plate to disconnect the connector at the

ower part. Then, remove the mounting plate.

F

Lens Mounting Plate Attachment

STUDIO ADAPTER SA-1000(Box type lens mount)

Lens Mounting Plate Removal

STUDIO ADAPTER SA-1000(Box type lens mount)

Move the lever to the Lock positionand place the camera on the mount base.

Move the lever to rock the mount base . Adjust and fit of the camera in the bayonetmount with holding the rear side of thecamera, and then press down the lock lever.

Move each of the levers and tothe Unlock position.While pushing the slide release pin ,slide the camera into the bayonet mount.

A

A

B

D

D

C

1 2

5 6 Camera attachment completed

3 4

A

Place the levers and in the Lock

position to stop the vertical and horizontal

movements of the camera, respectively.

Connect the viewfinder to camera.A D

C

A D B

CAMERA ATTACHMENT

STUDIO ADAPTER SA-1000(Box type lens mount)

Remove the view finder from the camera. Push the bayonet mount lever upwardto unlock the camera.

Pull the camera rearward to remove itfrom the bayonet mount.

Pushing the release button .Move the lever to unlock the mount base.

E

1 2

3 4

Remove the camera from the mount base.

E

Camera removal completed

CAMERA REMOVAL

STUDIO ADAPTER SA-1000(Box type lens mount)

Align the lugs of the build-up adapter with the lugs of the handy plate.Push the lower part of the handy plate.

Secure the plate by locking the rock screw.(M5 Hexagon wrench)

F G

A

D

2 3 4 Removal completed

Attachment completed

G

Remove the camera lens, and then move

the camera body rearward.

Remove the camera from the mount base. Loose the rock screw. Lightly tap the upper part of the mounting.

plate to disconnect the connector at the

ower part. Then, remove the mounting plate.

F

Lens Mounting Plate Attachment

STUDIO ADAPTER SA-1000(Box type lens mount)

Lens Mounting Plate Removal

STUDIO ADAPTER SA-1000(Box type lens mount)