  • 7/29/2019 Structural/Civil Engineer's Building Structure Column Checks ( structural design )

    1/10

    TIMES LENGTH WIDTH DEPTH DENSITY

    DEAD LOADS

    roof 1 5.5 6

    Ceiling 1 5.5 6

    Beam filling 0 0 0.23 0.35 20

    R/B Ring Beam 1 9 0.23 0.35 25

    Walls first flr(230TH) 0 19 0.23 3 20

    Walls grnd flr 0 9 0.23 3 20

    Slab(Ribbed) 0.5 5.5 6

    1 Beam 0.5 19 0.23 0.25 25

    1 slab Beam 0 0 0 0 25

    Grd Beam 0 19 0.23 0.3 25

    Column 1 12 0.23 0.23 25

    Back fill 1 1.75 1.75 1.5 18

    Pad 1 1.75 1.75 0.45 24

    Total

    LIVE LOADS

    Roof 1 5.5 6

    Floors(Ribbed) 0.5 5.5 6

    Total

    GRAND TOTAL

    Bearing Capacity

    180

    PAD DESIGN

    fy N/mm2

    460.0

    fcu N/mm2

    25.0

    cover to main bars mm 50

    assumed re-bar dia mm 16

    Col design load kN 288.39

    earth pressure kN/m2

    40

    d mm 376

    shear stress

    at col face, vcol N/mm2

    0.83

    0.8SQRTfcu N/mm2

    4.0

    OK

    critical perimeter mm 5,512area within perimeter mm

    21,898,884

    punching shear force, V kN 213

    punching shear stress, v N/mm2

    0.10

    Allowable shear stress vc N/mm2

    0.360

    OK

    Half base less half column 1.2

    Mat column face kN m 81

  • 7/29/2019 Structural/Civil Engineer's Building Structure Column Checks ( structural design )

    2/10

    Mu kN m 1,489

    A s mm2

    522

    minimum A s mm2

    1,580

    A s provided mm2

    2,510

    Provide 8T20@370cc

    (100As/bd) 0.247

    Allowable shear stress vc N/mm2 0.360

    OK

    at critical shear section, m 0.859

    V kN 92

    v N/mm2

    0.09

    OK

    mailto:8T20@370ccmailto:8T20@370cc
  • 7/29/2019 Structural/Civil Engineer's Building Structure Column Checks ( structural design )

    3/10

    UNIT LOAD TOTAL LOAD Factored

    kN/m2

    KN

    0.6 20

    0.6 20

    0

    18

    0

    0

    4.34 72

    14

    0

    0

    16

    83

    33

    275 159

    222.38825

    0.25 8

    2 33

    41 66 41

    66

    316 66.0 288.38825

    Pad Area Side req'd side provided

    1.75478472 1.325 2.70

    mailto:kN%5e&*%25$$#@!@%22%7C?//mailto:kN%5e&*%25$$#@!@%22%7C?//mailto:kN%5e&*%25$$#@!@%22%7C?//mailto:kN%5e&*%25$$#@!@%22%7C?//
  • 7/29/2019 Structural/Civil Engineer's Building Structure Column Checks ( structural design )

    4/10

  • 7/29/2019 Structural/Civil Engineer's Building Structure Column Checks ( structural design )

    5/10

  • 7/29/2019 Structural/Civil Engineer's Building Structure Column Checks ( structural design )

    6/10

    TIMES LENGTH WIDTH DEPTH DENSITY

    DEAD LOADS

    roof 1 5.5 6

    Ceiling 1 5.5 6

    Beam filling 0 0 0.23 0.35 20

    R/B Ring Beam 1 9 0.23 0.35 25

    Walls first flr(230TH) 1 19 0.23 3 20

    Walls grnd flr 0 9 0.23 3 20

    Slab(Ribbed) 1 5.5 6

    1 Beam 1 19 0.23 0.25 25

    1 slab Beam 0 0 0 0 25

    Grd Beam 0 19 0.23 0.3 25

    Column 1 12 0.23 0.23 25

    Back fill 0 1.75 1.75 1.5 18

    Pad 0 1.75 1.75 0.45 24

    Total

    LIVE LOADS

    Roof 1 5.5 6

    Floors(Ribbed) 2 5.5 6

    Total

    GRAND TOTAL

    Bearing Capacity

    250

    PAD DESIGN

    fy N/mm2

    460.0

    fcu N/mm2

    25.0

    cover to main bars mm 50

    assumed re-bar dia mm 16

    Col design load kN 933.24

    earth pressure kN/m2

    128

    d mm 376

    shear stress

    at col face, vcol N/mm2

    2.70

    0.8SQRTfcu N/mm2

    4.0

    OK

    critical perimeter mm 5,512area within perimeter mm

    21,898,884

    punching shear force, V kN 690

    punching shear stress, v N/mm2

    0.33

    Allowable shear stress vc N/mm2

    0.360

    OK

    Half base less half column 1.2

    Mat column face kN m 264

  • 7/29/2019 Structural/Civil Engineer's Building Structure Column Checks ( structural design )

    7/10

    Mu kN m 1,489

    A s mm2

    1,689

    minimum A s mm2

    1,580

    A s provided mm2

    2,510

    Provide 8T20@370cc

    (100As/bd) 0.247

    Allowable shear stress vc N/mm2 0.360

    OK

    at critical shear section, m 0.859

    V kN 297

    v N/mm2

    0.29

    OK

    mailto:8T20@370ccmailto:8T20@370cc
  • 7/29/2019 Structural/Civil Engineer's Building Structure Column Checks ( structural design )

    8/10

    UNIT LOAD TOTAL LOAD Factored

    kN/m2

    KN

    0.6 20

    0.6 20

    0

    18

    262

    0

    4.34 143

    27

    0

    0

    16

    0

    0

    506 506

    708.841

    0.25 8

    2 132

    140 224.4 140

    224.4

    647 224.4 933.241

    Pad Area Side req'd side provided

    2.58626 1.608 2.70