stronglumenoptoco.,ltd...4547984834491949684974 50035015 4975 4922 48504824 47764747 47104719...
TRANSCRIPT
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
1 / 16
LM-79-08 Test ReportFor
STRONG LUMEN OPTO CO.,LTD(Brand Name:N/A)
3/F,Bldg.A,Licheng Tech IND.,Xinhe Road, Shajing,Shenzhen China518104
High Bay Luminaires for Commercial and Industrial
Buildings
Model name(s): SL-UFOA00-110Y-R120-CRemake:Where Y for commercial use, it can be any letter or number.Where XXXX represent light angle, it can be R060, R090 or R120.
Where C for commercial use, it can be any letter or number.
Representative (Tested) Model:SL-UFOA00-110Y-R120-C(3000K)SL-UFOA00-110Y-R120-C(5000K)
Model Different: All construction and rating are the same, except CCT
Test & Report By: Review By:
Engineer: Grace Li Manager: Jason LuoDate: Mar 4, 2019
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
2 / 16
1.1 Product Information:Organization Name STRONG LUMEN OPTO CO.,LTDBrand Name N/AModel Number SL-UFOA00-110Y-R120-CSKU (if available) N/AType of Luminaire(for integral lamps, list base type and lamp type)
High Bay Luminaires for Commercial andIndustrial Buildings
Rated Voltage / Frequency 100-277Vac, 50/60 HzNominal Power 110WRated Initial Lamp Lumen --Declared CCT 3000K,3500K,4000K,4500K,5000K
LED Manufacturer Lumileds Holoding B.V.LED Model L128-2780RA35000Q1Sample Number BLC1812025E-L1(3000K),L2(5000K)Luminaire Aperture (for downlights) -- in.Luminaire Length -- mmLuminaires Width -- mmNumber of Units (modular products) N/A s
Photo
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
3 / 16
1.2 Test Specifications:Date of Receipt Feb 28, 2019Date of Test Mar 1, 2019
Test item
1. Total Luminous Flux2. Luminous Distribution Intensity3. Luminous Efficacy4. Correlated Color Temperature5. Color Rendering Index6. Chromaticity Coordinate7. Electrical Parameters
Reference Standard
1. IES LM-79-2008 Electrical and Photometric Measurements ofSolid-State Lighting Products
2. ANSI C78.377-2008 Specifications for the Chromaticity of SolidState Lighting Products
3. CIE 13.3-1995 Method of Measuring and Specifying ColourRendering Properties of Light Sources
4. CIE 15-2004 Technical Report Colorimetry5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source6. IESNATM-16-05 Technical Memorandum on Light Emitting
Diode (LED) Sources and SystemsReference Work Instruction BL-QP-033
1.3 Test Methods1) Photometric and Light Distribution Measurement – Goniophotometer Method:Photometric parameters were measured using the goniophotometer and software. The ambienttemperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from thesample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz.It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen werecalculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.2) Chromaticity Measurement – Sphere-Spectroradiometer Method:Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software.The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The samplemeasurements were made using a spectroradiometer connected by a fiber optic cable and detectorthrough the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC,60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated colortemperature and color rendering index were calculated from the spectral power distribution taken at 5nm intervals over the range of 380 to 780 nm.3) Electrical Measurements:Electrical parameters were measured using power meters incorporated in goniophotometer orsphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at25º C ± 1º C. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized beforemeasurement was made. Voltage, frequency, current, power, power factor and total harmonic distortionwere measured by and read from the power meter.
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
4 / 16
2.1 Electrical, Photometric and Chromaticity Measurements(Refer to Work Instruction BL-QP-033)
Test date 2019-03-01 Test Ambient: 25.2 º C
Test Orientation As intended Stabilization Time (min) 90
Model Number SL-UFOA00-110Y-R120-C(3000K)
Electrical Measurement:Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD%
BLC1812025E-L1
120.0 60 0.8872 106.19 0.9974 4.62
277.0 60 0.4153 103.87 0.903 8.48
DLC Pass Criteria >= 0.9(-3%) <= 20(+5)
Chromaticity Measurement - Sphere-Spectroradiometer Method:Parameter Result Special Color Rendering Indices
Test Voltage (V) 120.0 R1 68 R9 0
Frequency (Hz) 60 R2 81 R10 54
CCT (K) 3144 R3 91 R11 63
Duv 0.00029 R4 69 R12 42
Chromaticity (x, y) x=0.4274 y=0.4013 R5 67 R13 70
Chromaticity (u’, v’) u(u')=0.2456 v'=0.5189 R6 73 R14 95Color Rendering Index (CRI) 71.5 R7 78 R15 61
R9 0 R8 46 -- --
Photometric Measurement – Goniophotometer Method:Parameter Result DLC V4.4 Pass Criteria
Test Voltage (V) 120.0 277.0--
Frequency (Hz) 60 60
Total Luminous (lm) 18211.6 18092.0 >=10000(-10%)
Luminous Efficacy (lm/W) 171.50 174.18Premium: >= 130(-3%)
Most worst Luminous/Highest Watts 170.37
Zonal lumens in the 20-50° zone (%) 52.4 -- >=30(-10)
BeamAngle (°) 122.3 -- --
Center Beam Candle Power (cd) 6028 -- --
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
5 / 16
Zonal Lumen Tabulation
Zonal Lumen Summary
Zone Lumens % Lamp % Luminaire
0-30 4,781.5 26.3% 26.3%
0-40 8,018.4 44% 44%
0-60 15,501.0 85.1% 85.1%
60-90 2,701.1 14.8% 14.8%
70-100 662.7 3.6% 3.6%
90-120 0.1 0% 0%
0-90 18,202.1 99.9% 100%
90-180 7.3 0% 0%
0-180 18,209.4 100% 100%
Lumens Per Zone
Zone Lumens % Total Zone Lumens % Total
0-10 571.8 3.1% 90-100 0 0%
10-20 1,651.9 9.1% 100-110 0 0%
20-30 2,557.8 14.0% 110-120 0.1 0%
30-40 3,236.9 17.8% 120-130 0.4 0%
40-50 3,754.8 20.6% 130-140 1.2 0%
50-60 3,727.8 20.5% 140-150 1.7 0%
60-70 2,038.5 11.2% 150-160 1.9 0%
70-80 609.9 3.3% 160-170 1.4 0%
80-90 52.8 0.3% 170-180 0.5 0%
Spectral Power Distribution & Chromaticity Diagram
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
6 / 16
Photometric Data
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
7 / 16
Candela Table - Type C
0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360
0 6028 6028 6028 6028 6028 6028 6028 6028 6028 6028 6028 6028 6028 6028 6028 6028 6028
1 6033 6019 6015 6012 6032 6038 6047 6036 6039 6022 6035 6006 6032 6047 6026 6025 6033
2 6033 6019 6032 6022 6034 6028 6030 6027 6047 6023 6032 6015 6038 6025 6028 6019 6033
3 6019 6013 6010 6018 6025 6028 6042 6031 6056 6016 6026 6017 6015 6037 6036 6016 6019
4 6015 6008 6013 6023 6019 6036 6014 6013 6031 6010 6014 6020 6012 6024 6023 5993 6015
5 6016 5991 5998 5988 6009 6019 6030 6022 6022 6015 6024 5999 6014 6012 6014 5992 6016
6 6002 5977 6002 5989 6013 6022 6025 6007 6023 6012 6001 6000 5997 6012 5999 5985 6002
7 5985 5976 5987 5975 5996 6016 6012 6018 6014 5984 6000 5978 5997 5982 5987 5964 5985
8 5977 5943 5957 5966 5958 5998 6005 5990 6002 5980 5981 5980 5974 5978 5975 5957 5977
9 5971 5940 5957 5939 5968 5998 5985 5977 5992 5991 5972 5961 5958 5943 5958 5931 5971
10 5937 5908 5938 5946 5947 5964 5966 5973 5972 5950 5954 5948 5942 5930 5951 5918 5937
11 5918 5892 5917 5929 5936 5962 5952 5944 5951 5940 5936 5936 5925 5924 5896 5905 5918
12 5903 5876 5882 5901 5914 5926 5936 5908 5934 5908 5914 5909 5893 5900 5891 5882 5903
13 5869 5848 5874 5893 5908 5910 5919 5920 5918 5905 5895 5891 5881 5877 5881 5867 5869
14 5844 5835 5855 5873 5889 5899 5895 5899 5891 5892 5869 5868 5849 5849 5853 5837 5844
15 5824 5813 5832 5850 5853 5877 5891 5867 5876 5854 5861 5840 5845 5820 5807 5802 5824
16 5794 5786 5805 5832 5841 5859 5877 5856 5842 5827 5825 5817 5789 5791 5800 5781 5794
17 5773 5759 5778 5818 5828 5850 5848 5835 5831 5808 5800 5787 5780 5774 5775 5756 5773
18 5731 5733 5761 5787 5802 5829 5823 5821 5796 5785 5776 5761 5730 5744 5747 5724 5731
19 5706 5703 5739 5754 5756 5778 5801 5787 5778 5754 5741 5724 5714 5716 5708 5702 5706
20 5679 5668 5703 5725 5752 5738 5774 5756 5752 5719 5713 5704 5675 5675 5680 5643 5679
21 5651 5642 5680 5704 5709 5739 5752 5735 5728 5694 5686 5676 5647 5644 5614 5639 5651
22 5615 5593 5642 5679 5696 5695 5714 5699 5683 5650 5653 5630 5618 5609 5600 5598 5615
23 5581 5579 5609 5634 5641 5679 5693 5676 5659 5631 5609 5590 5571 5555 5548 5564 5581
24 5531 5547 5577 5611 5614 5647 5662 5628 5619 5588 5576 5543 5532 5527 5513 5526 5531
25 5493 5506 5550 5559 5592 5614 5637 5605 5598 5563 5536 5511 5496 5498 5481 5483 5493
26 5462 5466 5508 5545 5565 5591 5600 5566 5548 5518 5499 5461 5466 5451 5445 5439 5462
27 5412 5419 5463 5511 5505 5526 5552 5527 5525 5483 5448 5421 5424 5399 5392 5388 5412
28 5362 5371 5436 5488 5481 5506 5520 5492 5477 5425 5401 5394 5362 5354 5351 5350 5362
29 5320 5351 5392 5428 5452 5484 5487 5459 5446 5398 5374 5339 5328 5319 5306 5303 5320
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
8 / 16
30 5285 5298 5364 5404 5413 5446 5441 5425 5413 5356 5332 5298 5271 5270 5245 5253 5285
31 5239 5255 5333 5364 5388 5417 5413 5400 5370 5316 5277 5256 5234 5229 5214 5217 5239
32 5194 5233 5293 5342 5348 5379 5368 5365 5335 5274 5240 5214 5187 5184 5162 5166 5194
33 5159 5193 5247 5302 5286 5341 5354 5332 5298 5239 5217 5166 5151 5137 5132 5125 5159
34 5115 5158 5208 5271 5268 5307 5330 5290 5253 5193 5172 5135 5107 5086 5086 5072 5115
35 5080 5114 5191 5235 5241 5274 5288 5262 5221 5168 5127 5087 5067 5036 5048 5030 5080
36 5038 5083 5149 5218 5230 5246 5237 5230 5188 5134 5083 5042 5024 5001 4989 5002 5038
37 5004 5053 5129 5185 5197 5234 5234 5189 5172 5087 5042 5013 4979 4972 4957 4964 5004
38 4984 5017 5106 5152 5162 5209 5209 5165 5122 5064 5016 4968 4953 4925 4933 4930 4984
39 4944 4988 5077 5136 5134 5170 5176 5140 5098 5035 4977 4941 4918 4895 4892 4883 4944
40 4910 4954 5043 5100 5091 5142 5143 5103 5076 4994 4957 4904 4874 4860 4850 4857 4910
41 4891 4939 5015 5078 5058 5127 5109 5086 5049 4961 4920 4871 4846 4826 4820 4834 4891
42 4851 4915 4996 5062 5061 5089 5096 5066 5014 4946 4898 4850 4809 4799 4803 4819 4851
43 4824 4892 4967 5029 5029 5066 5078 5033 4986 4909 4867 4831 4799 4771 4757 4788 4824
44 4812 4856 4944 4999 4996 5030 5052 5012 4971 4886 4855 4802 4762 4739 4739 4757 4812
45 4798 4834 4919 4968 4974 5003 5015 4975 4922 4850 4824 4776 4747 4710 4719 4732 4798
46 4753 4814 4882 4931 4928 4970 4984 4954 4900 4830 4803 4752 4705 4695 4698 4713 4753
47 4729 4782 4852 4884 4895 4914 4923 4916 4867 4803 4780 4728 4683 4679 4665 4683 4729
48 4711 4744 4806 4839 4853 4882 4888 4867 4837 4775 4753 4709 4673 4650 4648 4658 4711
49 4675 4704 4769 4785 4798 4826 4838 4829 4795 4746 4714 4689 4618 4635 4609 4641 4675
50 4638 4648 4704 4727 4710 4743 4780 4771 4756 4710 4690 4655 4603 4590 4597 4604 4638
51 4581 4598 4611 4621 4639 4670 4705 4707 4698 4668 4652 4630 4573 4563 4556 4576 4581
52 4541 4522 4530 4512 4540 4581 4602 4634 4628 4607 4609 4580 4532 4512 4521 4537 4541
53 4459 4430 4424 4393 4404 4468 4505 4538 4558 4551 4556 4519 4491 4473 4455 4469 4459
54 4379 4334 4312 4256 4283 4322 4385 4433 4461 4477 4481 4451 4437 4414 4393 4389 4379
55 4248 4178 4131 4074 4123 4175 4232 4293 4352 4364 4387 4359 4351 4339 4314 4300 4248
56 4133 4030 3934 3889 3929 4006 4060 4134 4229 4251 4278 4253 4272 4246 4195 4154 4133
57 3955 3833 3735 3648 3703 3781 3861 3967 4065 4129 4155 4115 4132 4105 4053 3996 3955
58 3759 3615 3504 3392 3458 3546 3647 3751 3876 3967 3994 3966 4020 3975 3886 3796 3759
59 3512 3382 3262 3145 3223 3302 3421 3489 3667 3783 3822 3788 3843 3787 3704 3584 3512
60 3269 3114 3018 2899 2950 3029 3165 3231 3447 3553 3594 3570 3654 3587 3472 3314 3269
61 2988 2867 2727 2620 2690 2773 2878 2973 3199 3297 3374 3310 3418 3321 3205 3045 2988
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
9 / 16
62 2689 2560 2448 2346 2402 2475 2612 2653 2910 3028 3084 3042 3155 3047 2932 2731 2689
63 2396 2289 2185 2099 2152 2225 2350 2391 2631 2761 2802 2769 2871 2760 2659 2437 2396
64 2139 2018 1936 1878 1916 1978 2098 2138 2360 2474 2513 2478 2582 2481 2389 2169 2139
65 1902 1832 1725 1703 1708 1773 1863 1908 2113 2178 2239 2213 2311 2205 2117 1933 1902
66 1693 1625 1522 1527 1517 1589 1659 1707 1879 1933 1991 1970 2065 1968 1879 1716 1693
67 1509 1447 1366 1396 1347 1408 1484 1539 1662 1725 1749 1748 1816 1731 1664 1544 1509
68 1339 1300 1211 1265 1205 1269 1330 1380 1482 1537 1549 1561 1589 1530 1488 1385 1339
69 1187 1152 1081 1146 1076 1156 1186 1260 1316 1364 1382 1388 1402 1370 1313 1245 1187
70 1052 1027 943 1007 942 1033 1053 1144 1187 1230 1228 1268 1248 1234 1158 1106 1052
71 927 896 838 894 814 904 931 1017 1039 1101 1086 1129 1102 1103 1034 984 927
72 798 785 727 764 705 779 808 892 911 963 952 994 961 969 898 869 798
73 694 667 630 659 601 673 690 777 791 831 833 874 847 852 784 749 694
74 584 570 530 557 501 578 595 668 670 719 705 749 714 724 669 641 584
75 490 482 443 465 420 478 511 561 578 617 607 634 612 617 565 544 490
76 408 395 368 389 352 406 425 473 488 523 513 539 520 521 472 455 408
77 331 327 297 313 280 329 350 395 414 438 429 451 429 434 396 370 331
78 269 260 243 255 226 269 281 315 340 361 354 375 363 363 312 297 269
79 213 206 191 202 182 211 224 262 271 284 282 295 284 287 264 233 213
80 173 156 142 152 135 157 181 205 213 232 237 245 234 230 213 184 173
81 128 119 114 111 104 121 138 159 170 178 184 190 183 179 163 137 128
82 91 73 76 80 67 88 100 112 134 137 144 143 141 135 123 97 91
83 57 44 34 53 32 47 66 78 91 101 105 106 101 96 91 60 57
84 14 11 20 18 0 17 28 45 58 68 73 72 73 63 59 27 14
85 0 0 10 0 0 0 9 11 21 25 37 38 36 31 23 0 0
86 0 0 7 7 0 0 0 0 0 0 14 10 0 0 10 0 0
87 0 0 9 0 0 0 0 0 0 0 9 0 0 0 7 0 0
88 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
89 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
91 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
92 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
93 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
10 / 16
94 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
96 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
97 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
98 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
100 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
101 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
102 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
103 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
104 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
105 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
106 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
107 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
108 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
109 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
110 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
111 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
112 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
113 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
114 0 0 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0
115 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
116 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
117 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
118 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
119 0 0 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0
120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
121 0 0 0 7 0 0 0 0 0 0 0 0 0 0 0 0 0
122 0 0 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0
123 0 0 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0
124 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
125 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
11 / 16
126 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
127 0 0 8 8 0 0 0 0 0 0 0 0 0 0 0 0 0
128 0 0 8 0 0 0 0 0 0 0 0 0 0 0 8 0 0
129 0 0 7 0 0 0 0 0 0 0 10 0 0 0 0 0 0
130 0 0 9 0 0 0 0 0 0 0 0 0 0 0 10 0 0
131 0 0 9 0 0 0 0 0 0 0 7 0 0 0 0 0 0
132 0 0 8 0 0 0 0 0 0 0 8 0 0 0 0 0 0
133 0 0 7 8 0 0 0 0 0 0 8 0 0 0 0 0 0
134 0 0 11 7 0 0 0 0 0 0 0 0 0 0 7 0 0
135 0 0 9 0 0 0 0 0 0 0 8 0 0 0 7 0 0
136 0 0 9 8 0 0 0 0 0 0 9 8 0 0 0 0 0
137 0 0 9 8 0 0 9 0 0 0 8 0 0 0 8 0 0
138 0 0 10 9 0 0 0 0 0 0 0 9 0 0 0 0 0
139 0 0 7 0 0 0 0 0 0 0 7 0 0 0 0 0 0
140 0 0 7 9 0 0 0 0 0 0 9 0 0 0 9 0 0
141 0 0 11 0 0 0 0 0 0 0 0 0 0 0 8 0 0
142 0 0 11 9 0 0 8 0 0 0 11 0 0 0 0 0 0
143 0 0 9 10 0 0 8 0 0 0 12 0 0 0 8 0 0
144 0 0 10 7 0 0 0 0 0 0 0 0 0 8 8 0 0
145 0 0 10 12 0 0 8 0 0 0 10 11 0 0 11 0 0
146 0 0 10 10 0 0 0 0 7 0 0 0 0 0 0 0 0
147 0 0 13 10 0 0 0 0 0 0 10 8 0 7 9 0 0
148 0 8 9 0 0 0 8 0 0 0 0 11 0 0 8 0 0
149 0 0 15 7 0 0 8 0 0 0 11 0 0 0 12 0 0
150 7 0 13 10 0 0 11 0 8 0 13 10 0 8 13 0 7
151 7 8 13 9 0 0 10 0 0 0 12 8 0 0 11 0 7
152 0 0 10 8 0 0 9 0 0 0 10 0 0 0 7 0 0
153 0 0 12 10 0 0 11 0 0 0 9 0 0 9 8 0 0
154 0 0 15 11 0 0 0 0 0 0 8 0 0 0 8 0 0
155 8 0 17 12 0 0 10 0 0 0 9 8 0 0 10 0 8
156 10 10 13 8 0 0 9 0 8 0 12 11 0 0 13 0 10
157 8 0 13 12 0 0 8 0 0 0 10 7 0 7 11 0 8
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
12 / 16
158 0 0 13 11 0 0 8 0 0 0 10 9 0 0 10 0 0
159 0 0 12 9 0 0 9 8 0 0 10 8 0 0 11 0 0
160 0 0 14 11 0 0 11 0 0 0 10 8 0 0 10 0 0
161 7 0 14 9 0 0 11 0 9 0 11 11 0 0 11 0 7
162 8 0 12 12 0 0 8 0 0 0 11 11 0 0 10 0 8
163 8 0 14 9 0 0 11 0 0 0 13 0 0 0 11 0 8
164 0 10 0 8 0 0 8 0 9 0 16 9 0 8 10 0 0
165 8 0 15 11 0 0 7 0 8 0 14 7 0 0 10 0 8
166 0 0 17 13 0 0 11 0 0 0 10 9 0 7 12 0 0
167 10 0 18 7 0 0 9 8 0 0 7 12 0 7 10 0 10
168 8 0 9 12 0 0 9 8 9 0 12 13 0 0 9 0 8
169 10 0 14 9 0 0 0 9 10 0 11 11 0 9 10 0 10
170 0 8 16 0 0 0 11 0 8 0 13 9 0 0 14 0 0
171 0 7 14 9 0 0 10 0 10 0 11 8 0 0 10 0 0
172 7 9 15 14 0 0 9 0 0 0 11 9 0 0 14 9 7
173 8 8 13 12 0 0 9 0 8 7 9 11 0 8 8 0 8
174 0 0 16 12 0 0 8 0 8 0 10 10 0 7 9 0 0
175 10 8 12 12 0 0 7 0 11 0 16 8 0 8 12 0 10
176 0 12 16 14 0 0 0 0 8 0 12 9 0 0 10 0 0
177 0 0 12 11 0 0 0 0 9 0 10 9 0 0 12 0 0
178 0 0 13 9 0 0 10 0 8 0 11 9 0 0 7 0 0
179 0 0 15 10 0 0 10 0 12 0 8 10 0 0 10 0 0
180 0 0 9 11 0 0 0 0 10 0 17 12 0 0 8 0 0
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
13 / 16
2.2 Electrical, Photometric and Chromaticity Measurements(Refer to Work Instruction BL-QP-033)
Test date 2019-03-01 Test Ambient: 25.2 º C
Test Orientation As intended Stabilization Time (min) 90
Model Number SL-UFOA00-110Y-R120-C(5000K)
Electrical Measurement:Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD%
BLC1812025E-L2
120.0 60 0.8880 106.15 0.9962 4.95
277.0 60 0.4132 103.85 0.9074 8.69
DLC Pass Criteria >= 0.9(-3%) <= 20(+5)
Chromaticity Measurement - Sphere-Spectroradiometer Method:Parameter Result Special Color Rendering Indices
Test Voltage (V) 120.0 R1 71 R9 0
Frequency (Hz) 60 R2 78 R10 46
CCT (K) 5032 R3 82 R11 71
Duv 0.0045 R4 74 R12 40
Chromaticity (x, y) x=0.3456 y=0.3672 R5 71 R13 72
Chromaticity (u’, v’) u(u')=0.2058 v'=0.4921 R6 69 R14 90Color Rendering Index (CRI) 73.5 R7 83 R15 65
R9 0 R8 60 -- --
Photometric Measurement – Sphere-Spectroradiometer Method:Parameter Result DLC V4.4 Pass Criteria
Test Voltage (V) 120.0 277.0--
Frequency (Hz) 60 60
Total Luminous (lm) 19181.3 19230.9 >=10000(-10%)
Luminous Efficacy (lm/W) 180.70 185.18Premium: >= 130(-3%)
Most worst Luminous/Highest Watts 180.70
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
14 / 16
Spectral Power Distribution & Chromaticity Diagram
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
15 / 16
Calculated Efficacy Data for family models (3500K, 4000K, 4500K and 5000K):Model Number Luminous Flux (lm) Power (W) Efficacy (lm/W)
SL-UFOA00-110Y-R120-C(3000K) 18211.6 106.19 171.50SL-UFOA00-110Y-R120-C(3500K) 18454.0 106.17 173.82SL-UFOA00-110Y-R120-C(4000K) 18696.5 106.17 176.10SL-UFOA00-110Y-R120-C(4500K) 18938.9 106.17 178.38SL-UFOA00-110Y-R120-C(5000K) 19181.3 106.15 180.70
Report No.: BLC1812025E-L
Laboratory: Belling Test Laboratory Co., LTD A2LACertificate# 4810.01Unit 401, No. 309 Xinxin Seven Road, Zengcheng District,
Guangzhou, People’s Republic of China. Website: http://www.bltst.comReport Format Number BL-FM-SA-012
16 / 16
3. Test Equipment
Equipment Name Model No. Serial No. Next Calibration Date
Goniophotometeric System GPM-3000 DYHXF120001 2020-01-14
AC Power Source CHP-500C N/A 2020-01-13
Total Luminous Flux StandardLamp
24V/150W DYJYR040040 2020-01-21
Digital Power Meter WT500 DYDWQ200006 2020-01-13
Integral Sphere (2M) 2M DYJCE120067 2020-01-14
Digital Power Meter WT500 DYDWQ200006 2020-01-13
Optical Color and ElectricalMeasurement System
CMS-3000S DYJCE120067 2020-01-14
Expand Uncertainty:Photometric Measurement (Sphere): 2.04%, k=2Chromaticity Measurement(Sphere):28.8K, k=2Photometric Measurement(Goniophotometer):2.7%, k=2
****** END OF REPORT ******