Receiver to Transmitter interface cable protection
The lightning protection bulkhead offered by Wxline should be installed and properly bonded to a conductor that is near and common to the building earth ground system. To further improve personal safety and equipment protection during a local thunderstorm, a secondary surge arrestor (for commercial AC power) should be installed at the building service entrance (per NEC). In addition, the RF cable used by WAVE equipment should enter the building at the service entrance and should pass through an appropriate, grounded RF surge suppressoror a ground block at the building service entrance.
Interface Cable—from Receiver to Transmitter (via surge arrestor)
Copper ground plate
Bond strap to buildingelectrical ground
Interface cable to Receiver relay
To outdoor antenna (via RF surge arrestor or ground block at the buildingservice entrance)
Wood mounting board
White board with copper ground plate
Strike Guardinline switchingpower supply
To AC power
Power in
Power in
Equipment bond strap to copper plate
WAVE Transmitterinline switchingpower supply
Antenna surge arrestor
Copper bond strap betweenReceiver and Transmitter (under wall-mount plates)
WARNING - DANGERNever touch WAVE or Strike Guard equipment
during a local thunderstorm - you could get
shocked or killed!
Strike Guard Lightning Data Receiver/WAVE Transmitter Lightning Protection Bulkhead Installation LLC