strength in numbers - matching lamb wave sensors ... - … · strength in numbers matching lamb...

3
20 February 2012 Flow Control installation guidelines Strength in Numbers Matching lamb wave sensors to the resonant frequency of a pipe wall C lamp-on ultrasonic flowmeter technology offers several major advantages over other methods of flow measurement when it comes to accounting for what, and how much, is flowing through a pipe. These benefits are derived primarily from one very important feature of clamp-on ultrasonic meters — i.e., their external sensors. Unlike traditional insert sensors, external sensors do not require pipes to be cut or operations to be halted in order to complete the installation process. Instead, the sensors are mounted on the exterior of the pipe and measure flow by transmit- ting acoustic signals into the pipe wall before entering the fluid. The question may arise as to how well a meter can perform if its sensors never make contact with the medium flowing inside the pipe. But the fact is, clamp-on ultrasonic flowmeters can demonstrate a very high level of accuracy and reliability that is on par with or even better than other flow measurement technolo- gies. The key to determining whether this type of flowmeter lives up to its potential lies in properly matching the sensors to the pipe containing the fluid to be measured. Given that clamp-on meters are capable of measuring flow within pipes of varying diameters, materials and wall thicknesses, it is imperative for suppliers to offer a suitably broad range of clamp-on Lamb wave sensors with differing frequencies. This will help users to achieve the best possible match between the sensors and the resonant frequency of the pipe wall, ultimately resulting in more accurate flow measurement. Shear Mode vs. Lamb Wave Sensors To explain why it is so important to match the external sensors to the pipe being measured, it is first necessary to distinguish between two different types of sensors that can be utilized by clamp-on ultrasonic flowmeters — shear-mode and Lamb wave. Shear-mode or narrow-beam sensors are the most common type used in clamp-on flow measurement and demonstrate reasonably good performance within a limited range of process conditions. Shear-mode sensors inject an acoustic signal into the pipe wall, effectively forcing the signal through the pipe and into the opposing sensor (Figure 1). Although this technology is easier and less expensive to employ than Lamb wave sensors, it is sensi- tive to suspended solids and bubbles exceeding a few percent by volume. This can lead to poor performance or even complete loss of the receive signal. Shear-mode sensors are most suitable for flow surveys and check metering applications requiring the use of a portable flowmeter kit, which is not generally designed to carry a large selection of sensors. However, for the majority of dedicated metering applications, it is preferable to use Lamb wave technol- ogy for better accuracy over a wider range of liquid conditions. Lamb wave or wide-beam sensors operate by broadcast- ing various frequencies through the pipe in order to locate the frequency most closely matched to that of the pipe wall. This frequency is transmitted into the flowing media with the pipe wall acting as a waveguide (Figure 2). This method employs a lower transmit voltage (approximately 30 volts) and produces a particularly strong and focused signal covering a large axial area of the pipe’s inside diameter. This results in a much higher signal amplitude than is the case for the shear mode. In addition, the wider beam offers formidable resistance against the effects of suspended solids and bubbles. Therefore, there would have to be a significantly higher concentration of interfering particles to dis- turb the beam and cause signal loss, making Lamb wave sensors Figure 1. Shear-mode (narrow-beam) sensors Figure 2. Lamb wave (wide-beam) sensors 2-4 MHz sensors: Ideal for operation on small diameter thin-wall steel tubing, allowing the sensors to be installed on the same side of the tube. 350-1500 KHz sensors: General-purpose sensors covering most flow applications. 150-300 KHz sensors: Appropriate for large penstock, hydroelectric and natural gas applications with pipe wall thick- nesses up to 32 mm (1.25 in). Lamb Wave Sensors: What’s Your Type?

Upload: dothuy

Post on 14-May-2018

223 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Strength in Numbers - Matching Lamb Wave Sensors ... - … · Strength in Numbers Matching lamb wave sensors to the resonant ... sensors do not require pipes to be cut or operations

20 February 2012 Flow Control

installation guidelines

Strength in NumbersMatching lamb wave sensors to the resonant frequency of a pipe wall

Clamp-on ultrasonic flowmeter technology offers several major advantages over other methods of flow measurement when it comes to accounting for what, and how much, is

flowing through a pipe. These benefits are derived primarily from one very important feature of clamp-on ultrasonic meters — i.e., their external sensors. Unlike traditional insert sensors, external sensors do not require pipes to be cut or operations to be halted in order to complete the installation process. Instead, the sensors are mounted on the exterior of the pipe and measure flow by transmit-ting acoustic signals into the pipe wall before entering the fluid.

The question may arise as to how well a meter can perform if its sensors never make contact with the medium flowing inside the pipe. But the fact is, clamp-on ultrasonic flowmeters can demonstrate a very high level of accuracy and reliability that is on par with or even better than other flow measurement technolo-gies. The key to determining whether this type of flowmeter lives up to its potential lies in properly matching the sensors to the pipe containing the fluid to be measured.

Given that clamp-on meters are capable of measuring flow within pipes of varying diameters, materials and wall thicknesses, it is imperative for suppliers to offer a suitably broad range of clamp-on Lamb wave sensors with differing frequencies. This will help users to achieve the best possible match between the sensors and the resonant frequency of the pipe wall, ultimately resulting in more accurate flow measurement.

Shear Mode vs. Lamb Wave SensorsTo explain why it is so important to match the external sensors to the pipe being measured, it is first necessary to distinguish between two different types of sensors that can be utilized by clamp-on ultrasonic flowmeters — shear-mode and Lamb wave.

Shear-mode or narrow-beam sensors are the most common type used in clamp-on flow measurement and demonstrate reasonably good performance within a limited range of process conditions. Shear-mode sensors inject an acoustic signal into the pipe wall, effectively forcing the signal through the pipe and into the opposing sensor (Figure 1). Although this technology is easier

and less expensive to employ than Lamb wave sensors, it is sensi-tive to suspended solids and bubbles exceeding a few percent by volume. This can lead to poor performance or even complete loss of the receive signal. Shear-mode sensors are most suitable for flow surveys and check metering applications requiring the use of a portable flowmeter kit, which is not generally designed to carry a large selection of sensors. However, for the majority of dedicated metering applications, it is preferable to use Lamb wave technol-ogy for better accuracy over a wider range of liquid conditions.

Lamb wave or wide-beam sensors operate by broadcast-ing various frequencies through the pipe in order to locate the frequency most closely matched to that of the pipe wall. This frequency is transmitted into the flowing media with the pipe wall acting as a waveguide (Figure 2). This method employs a

lower transmit voltage (approximately 30 volts) and produces a particularly strong and focused signal covering a large axial area of the pipe’s inside diameter. This results in a much higher signal amplitude than is the case for the shear mode. In addition, the wider beam offers formidable resistance against the effects of suspended solids and bubbles. Therefore, there would have to be a significantly higher concentration of interfering particles to dis-turb the beam and cause signal loss, making Lamb wave sensors

Figure 1. Shear-mode (narrow-beam) sensors

Figure 2. Lamb wave (wide-beam) sensors

✓2-4 MHz sensors: Ideal for operation on small diameter thin-wall steel tubing, allowing the sensors to be installed on the same side of the tube.✓350-1500 KHz sensors: General-purpose sensors covering

most flow applications.✓150-300 KHz sensors: Appropriate for large penstock,

hydroelectric and natural gas applications with pipe wall thick-nesses up to 32 mm (1.25 in).

Lamb Wave Sensors: What’s Your Type?

Page 2: Strength in Numbers - Matching Lamb Wave Sensors ... - … · Strength in Numbers Matching lamb wave sensors to the resonant ... sensors do not require pipes to be cut or operations

www.FlowControlNetwork.com February 2012 21

by James Doorhy

a good fit for applications containing up to 15 percent suspended solids or bubbles. They are designed primarily for steel pipes and are the preferred sensor type for hydrocarbon and gas applica-tions. This method does, however, require a wider range of sen-sors to be made available due to its dependency on the resonant frequency of the pipe wall, a relationship that will be more closely examined in the following sections.

Why Variety Is KeyClamp-on ultrasonic flowmeter suppliers have publicly acknowl-edged in marketing literature and academic papers the impor-tance of offering a variety of Lamb wave sensor frequencies for optimal flow measurement results. By making a range of Lamb wave sensors available, suppliers can help pipeline operators attain the strongest possible signal and highest level of measure-ment accuracy.

The need for a large number of Lamb wave sensors is based on well-established scientific principles related to Lamb or plate wave behavior. Lamb waves represent a complex form of acoustic wave propagation in a plate, in which the wave velocity depends on the relationship between the plate thickness and wavelength.

There are high-precision sensors designed to excite a specific

mode of Lamb wave within a bounded pipe wall. This mode, a zero-order anti-symmetric flexural mode Lamb wave, exists over the entire range of frequencies (from zero to infinitely high) and is characterized by particle displacement that is primar-ily perpendicular to the surface. The guided wave approach of the high-precision sensors is very different from narrow-beam sen-sors, where propagation velocity is only dependent on the proper-

Figure 3. Phase velocity dispersion curves for 4.7 mm steel pipe wall 1

NEOPERL, Inc. • Waterbury, CTTel 203-756-8891 • Fax 203-754-5868 • [email protected]

www.neoperl.com

• Versatile acetal copolymer• Rated up to 150°F• EPDM O-ring• NSF 61 certifi ed models

To hot water systems• Glass-fi lled acetal• Rated up to 175°F• EPDM O-ring• Superior temperature resistance

Flow RegulatorsFrom drinking water…

Covering a range of sizes from OD 5/16” to 15/16”, NEOPERL® pressure compensating fl ow regulators are easy to insert into your application device and maintain a constant fl ow (fl ow rates from 0.1 to 30 gpm).

• Versatile acetal copolymer• Rated up to 150°F• EPDM O-ring• NSF 61 certifi ed models

To hot water systems• Glass-fi lled acetal• Rated up to 175°F• EPDM O-ring• Superior temperature resistance

Flow RegulatorsFrom drinking water…

Covering a range of sizes from OD 5/16” to 15/16”, NEOPERL® pressure compensating fl ow regulators are easy to insert into your application device and maintain a constant fl ow (fl ow rates from 0.1 to 30 gpm).

FLOW

HUMIDITY

TEMPERATURE

FLOW

HUMIDITY

TEMPERATURE

FLOW

HUMIDITY

TEMPERATURE

Outstanding Flow Sensor Solutions

Featuring the MFS02 micro flow sensor:• 0 to 50m/s flow range• 0.001m/s sensitivity• < 10ms response time• Flow direction indicated

5 mm

3.5 mm

www.ist-usadivision.com

IST_quarter.indd 1 1/17/12 1:48 PM

Circle 16 or Request Info Instantly at www.FlowControlNetwork.comCircle 15 or Request Info Instantly at www.FlowControlNetwork.com

Page 3: Strength in Numbers - Matching Lamb Wave Sensors ... - … · Strength in Numbers Matching lamb wave sensors to the resonant ... sensors do not require pipes to be cut or operations

ties of the pipe material and not on the thickness of the pipe wall or the frequency of the sensor.

A pipe wall tends to oscillate with a greater amplitude when it is driven at one of its resonant frequencies. Many of these modes of resonance can occur inside a single pipe, represent-ing multiples of the fundamental frequency known as harmonics. However, the strongest and most easily excited is the zero-order, anti-symmetric mode used by high-precision sensors.

For Lamb wave propagation, the phase velocity and signal attenu-ation in the bounded pipe wall are described by associated disper-sion curves. These dispersion curves represent the various sinusoidal or sine wave solutions to the wave equation, where the boundary conditions are defined by the free pipe wall or plate surfaces.

As an example, the phase velocity dispersion curves for a 4.7 mm steel plate are shown in Figure 3, with each curve represent-ing a Lamb wave (A = anti-symmetric, S = symmetric). The A0 curve represents the zero-order anti-symmetric mode. A more general dispersion graph would be plotted against the product of frequency and wall thickness (MHz·mm) since it naturally scales with wavelength to wall thickness. Following the trend of the A0 curve, the phase velocity gradually increases with increasing fre-quency until the limit indicated by the Rayleigh wave velocity.

A Rayleigh wave is a type of surface acoustic wave that propa-gates along a single surface of a very thick plate. A Lamb wave will behave like, and approach the velocity of, a Rayleigh wave when its wavelength becomes much smaller than the plate thick-

ness. Rayleigh waves cannot inject acoustic energy into the fluid because this type of wave propagation limits particle displacement to only the outer surface of the pipe wall. For this reason, utilizing a Lamb wave sensor with the incorrect frequency for a given pipe (i.e., a pipe with a wall thickness much greater than one wavelength) will result in a significant reduction of the fluid signal amplitude, while also increasing the amplitude of the undesirable pipe wall signal.

In addition to reducing signal amplitude, operation of a Lamb wave sensor too far from the ideal pipe wall frequency will also lead to an increase in flow error (Figure 3). This is primarily due to the fixed-phase velocity of the sensor, which is defined by its wedge angle and sound speed.

A Worthwhile EndeavorCareful study of Lamb wave propagation has demonstrated a cru-cial fact — the likelihood of flow measurement error increases substantially if the frequency broadcast by a Lamb wave sensor is not well matched to the resonant frequency of the pipe wall. In the end, selecting the best possible sensor for a specific flow application will prove well worth the effort — for both the suppli-er and the end-user. FC

James Doorhy is the ultrasonic flow product manager for Siemens AG. Mr. Doorhy has over 20 years of experience in the ultrasonic flow industry, specializing in hydrocarbon flow and pipeline leak detection. He frequently serves as trainer and presenter for numerous international flow measurement events. He is knowledgeable on flow applications in various industries, including oil & gas, HVAC, water & wastewater, and power. Mr. Doorhy can be reached at [email protected] or 631 231-3600, ext. 1258.

References1. Moreno, E., Otero, R., Rubio, B., Galarza, N., Otero, J., & O’Connor, J, Phase Velocity Method for Lamb Waves in Pulse Echoes, 10th European Conference on Non-Destructive Testing, Moscow, 7-10 June 2010.

www.siemens.com

installation guidelines

22 February 2012 Flow Control

Lamb wave or wide-beam sensors operate by broadcasting various frequencies through the pipe in order to locate the frequency most closely matched to that of the pipe wall.

There are several limitations that should be considered before selecting Lamb wave sensors over the more common shear wave sensors:✓Pipe material must be compatible with Lamb wave

sensors. Most available Lamb wave sensors are designed for the more common steel pipe materials (e.g., stainless steel, carbon steel); however, operation may be extended to alumi-num, titanium, duplex steel, and other metals. Operating Lamb wave sensors on plastic, copper, copper-nickel, cast iron, or other low-sound velocity pipe materials will offer no benefit over the standard shear wave sensor.✓Diameter-to-wall thickness ratio should be greater

than 10-to-1. The Lamb wave frequency is inversely propor-tional to the pipe wall thickness. This relationship becomes problematic for small-diameter, thick-wall pipes where opera-tion at low frequency causes reduced flow sensitivity and inter-ference from synchronous acoustic noise traveling around the pipe instead of through the fluid.✓Maximum wall thickness limit should not be exceeded.

Lamb wave sensors are designed to operate over a range of pipe wall thicknesses, with the upper limit based on the lowest frequency sensor available from the manufacturer. Operation on a wall thickness that is much greater than the maximum allowed will result in unreliable performance and a significant reduction in signal amplitude.

When Should You Use Lamb Wave Sensors?