stream data loggers and diy instructions for protective housings and deployment
TRANSCRIPT
![Page 1: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/1.jpg)
Stream Data Loggers and DIY Instructions for Protective Housings and Deployment
The following is a brief presentation on the application of data loggers for stream water quality monitoring as currently used in the Iron Furnace Trout Unlimited water quality monitoring network in southern Allegheny National Forest.
Shown are two types of data loggers for monitoring specific conductance & temperature, custom built protective housings for the loggers, and how to generally deploy loggers in streams.
Visit our web site for additional info: www.ironfurnacetu.net
![Page 2: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/2.jpg)
Solinst Data Logger
Conductivity Range: 0 – 80,000 µS/cmAccuracy: 2% accuracy @ 500 – 80,000 µS/cmAccuracy: highly variable < 500 µS/cm
Also records temperature and pressure (level)
![Page 3: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/3.jpg)
Hobo Data Logger
Conductivity Range (low setting): 0 – 1,000 µS/cmAccuracy: 2% 0 – 1,000 µS/cm
Also records temperature & has full conductivity range @0 – 10,000 µS/cm
![Page 4: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/4.jpg)
Logger Housing Parts and Assembly
Stainless Eye-Hook
Cap Adapter Adapter Cap1 ½ “ PVC
PVC PipeCement
PVC PipeCleaner
Zip Tie
![Page 5: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/5.jpg)
Assembled Logger Housing
Watercirculation holes
Painted Housing(neutral color)
![Page 6: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/6.jpg)
Log
ger H
ousi
ng P
arts
List
![Page 7: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/7.jpg)
Installation Materials/Equipment
Concrete Form Stake
Ferrule Clamp Tool
1/8” Ferrules1/8” Cable
![Page 8: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/8.jpg)
Logger Ready for Deployment~ 3’ of 1/8” Cable
Single 1/8” ferrule
for cable stop
1/8” Double ferrule to form loop
Predrilled concrete form stake
Zip tie secures logger in housing
![Page 9: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/9.jpg)
Logg
er S
take
d in
Pla
ce
![Page 10: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/10.jpg)
Logg
er S
take
d in
Pla
ceU
nder
Brid
ge A
fter 6
0 D
ays
![Page 11: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/11.jpg)
Logger Housing after 60 Days
![Page 12: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/12.jpg)
Deploying LoggersPlace in stream locations that have:• Reasonable, safe access (distance from roads,
avoid base of steep slopes etc.);• Water depth to maintain submersion of logger
during periods of low flow in late summer/fall;• Locations with good water flow/mixing but not
overly turbulent - riffles and runs are generally preferred;
• Substrate that a stake can be drive into (avoid bedrock areas);
• Shaded locations to avoid solar heating of housing;
• Locate loggers away from human traffic to avoid disturbance or vandalism;
![Page 13: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/13.jpg)
Deploying LoggersOther Considerations:• Remember that loggers may need to be removed
when stream temperatures are very low during winter months when water depth and flows may be considerably higher and therefore dangerous;
• Strategically place flagging tape at your sites to allow you to find loggers and GPS logger locations;
• Download data directly in the field to a laptop or use a manufacturers remote data retrieval device;
• Sites with poor water quality require more frequent maintenance and visits as units foul more frequently;
• Use loggers with conductivity ranges appropriate (i.e., sensitivity and accuracy) to your streams.
![Page 14: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/14.jpg)
Logger Data Quality• To insure data integrity for these or other data
loggers follow manufactures instructions for calibration of loggers;
• Solinst recommends calibration every 6 months, more frequently if water quality is very poor;
• Hobo loggers require conductivity readings to be taken with a calibrated instrument at time of deployment and when units are removed to correct data;
• IFTU has Solinst loggers calibrated at a certified lab to insure data quality;
• IFTU uses a certified lab calibration standard for correction of Hobo logger data to insure data quality .
![Page 15: Stream data loggers and diy instructions for protective housings and deployment](https://reader033.vdocuments.us/reader033/viewer/2022060115/557cebe5d8b42a057f8b4e0f/html5/thumbnails/15.jpg)
For additional information contact:
Bruce Dickson, PhDWater Quality Monitoring CoordinatorIron Furnace Trout Unlimited
Phone: 814-227-9126