HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Status of HER Arc RF Seals

M. SullivanFor the PEP-II team

Machine Advisory Committee ReviewNovember 15-17, 2007

Page 2: Status of HER  Arc RF Seals

2

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Outline• Quick review of status last October

• Discoveries during Run 6

• Status of replacement effort

• Summary

Page 3: Status of HER  Arc RF Seals

3

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Story as of last October• We had found 5 bad RF flex flange seals and

had replaced them with new (same design and material) seals

• We had borescoped the beam pipe as much as we could in 2 of the 6 arcs looking for other bad RF seals and did not see any other bad seals

• We were trying to think of some way of instrumenting at least some of the seals

Page 4: Status of HER  Arc RF Seals

4

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Example of a melted RF seal

Inside of ring

These GlidCop fingers are brazed onto the SS mounting plate

Page 5: Status of HER  Arc RF Seals

5

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Molten copper

Page 6: Status of HER  Arc RF Seals

6

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

RF seal from Arc 7

Inside of ring

Arcing deposits enough heat to locally melt the copper

Page 7: Status of HER  Arc RF Seals

7

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

These omega fingers are over crushed

Melted the Ag plating

Silver melts at 1200 deg C(2200 def F)

Page 8: Status of HER  Arc RF Seals

8

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Some Numbers from last October• Each arc has 32 cells. Each cell has a bellows

module with 2 RF seals and a zero length (flex flange) bellows with one RF seal.

• Arc 9 – 11 cells worth of bellows and flex flange RF seals checked– All bellows ok– 3 flex flange RF seals melted

• Arc 7– 18 cells worth of bellows and flex flange RF seals checked

(8 cells checked in July of these 8 four were rechecked)– 3 bellows replaced in July 2006– 1 bellows found with several disconnected fingers– 1 bellows found with 1-2 displaced fingers– 2 flex flange RF seals melted

• Arc 1 (Some evidence of a problem but did not look)• No problems with any of the RF seals at the bellows

Page 9: Status of HER  Arc RF Seals

9

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

MechanicsPlan View

The zero length bellows is located on the long ~5.4 m dipole chamber where it attaches to the quadrupole chamber

Pivot Point

Fixed arm

Allowed chamber motion

Quadrupole chamber

Page 10: Status of HER  Arc RF Seals

10

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Findings During Run 6• We decided to instrument the flange joint with a TC

attached to the Cu as close as possible to the top bolt holding the RF seal plate even though the Cu is water cooled

• We started to find remarkably high temperature readings on certain seals and decided we needed to instrument every single RF seal

• By the middle of June we had attached a TC to all but about 5 joints

• We found a large number of seals with temperature increases of over 50 deg F T

Page 11: Status of HER  Arc RF Seals

11

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Location of the TC

The RF seal is almost thermally isolated

Page 12: Status of HER  Arc RF Seals

12

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

More Run 6 findings• Throughout the run we identified several particular RF seals

that had a very high temperature increase (as much as 100 deg F T) associated with beam aborts in the HER and with vacuum spikes in nearby pumps

• We had on hand ten seals with Inconel fingers and started to replace particularly bad seals with these new seals

• The new seals showed very good temperature behavior which prompted us to consider replacing a significant fraction of the 192 RF seals in the HER this fall

• We initially thought we could only replace about 120-150 seals but the MFD group here at SLAC developed a production line that will give us enough seal sets to replace all 192 flex seals (minus the 5 we had already installed during the run)

Page 13: Status of HER  Arc RF Seals

13

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

PR12 Arc 1b

Tally 61 50 44 18 9

July 3-6, 2007

HER Current

3 Days

Good

Bad

Bad

Good

Page 14: Status of HER  Arc RF Seals

14

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

PR06 Arc 5c

Inspected 10jul07

Replaced 10jul07 Inc

Inspected 10jul07

Inspected 10jul07 Inspected 10jul07

Some melting

Looked OK Looked OK

Some melting

Page 15: Status of HER  Arc RF Seals

15

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

PR06 Arc 5c

Inspected 10jul07

Replaced 10jul07 Inc

Inspected 10jul07

Inspected 10jul07 Inspected 10jul07

Some melting

Looked OK Looked OK

Some melting

Page 16: Status of HER  Arc RF Seals

16

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Spreadsheet indicating high temperature (RED) and low temperature (Blue) RF seals for 3 different data sets. Also compared to peak temperature data.

We removed this seal in order to inspect it

Page 17: Status of HER  Arc RF Seals

17

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

New RF Seal DesignSame as the old design but omega fingers made out of silver plated Inconel. The entire SS plate is silver plated.

Page 18: Status of HER  Arc RF Seals

18

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Replacement Progress• We quickly found that looking at the seals with a bore scope did

not tell us whether or not the seal was damaged so we started replacing all seals soon after starting

• We have replaced over 155 RF seals

• So far we have found 7 seals that look OK (No visible damage like arcing, melting etc.)

• Of the 155 bellows we have looked at we have had to replace about 5 due to previously identified small leaks or to bellows finger problems. None of the bellows have shown any sign of arcing and/or heating. Nor have nay of the bellows RF seals.

• We are making excellent progress and still plan to replace all the RF seals in the HER before we startup next month

Page 19: Status of HER  Arc RF Seals

19

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

These pictures are from the worst RF seal found in arc 1

The SS plate is distorted

Copper melts at 1080 deg C

SS melts at 1540 deg C(2550 deg F)

Page 20: Status of HER  Arc RF Seals

20

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

These pictures are from the worst RF seal found in arc 5

I estimate about 200 W of power are needed to melt the SS washer

Page 21: Status of HER  Arc RF Seals

21

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

An RF seal that we replaced last fall

This seal looks as bad as some of the worse seals that have been in the machine since day one

Page 22: Status of HER  Arc RF Seals

22

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Signs of arcing

These pictures are from a seal in arc 3 (PR04-6031).

This is not an unusual seal.

Page 23: Status of HER  Arc RF Seals

23

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

RF seal from arc 7

Note the crushed fingers

Page 24: Status of HER  Arc RF Seals

24

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Surface on the long dipole chamber

New Inconel RF seal installed

Page 25: Status of HER  Arc RF Seals

25

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Inconel seal that was installed July 10

This seal was not silver plated

The seal looks fine. None of the fingers are damaged and all of the fingers look like they made contact with the adjoining surfaces

Page 26: Status of HER  Arc RF Seals

26

HER Arc RF sealsM. Sullivan

MAC ReviewOct. 25-27, 2006

Summary• Last fall, in looking for bad bellows we uncovered a problem

with the RF seals at the flex flange in the HER. We initially thought the problem was not as extensive as it turned out to be.

• We eventually began to suspect we had a high percentage of failures when we were able to instrument most of the flex flanges with TCs sometime in May-June

• During this present down the percentage of RF seals with arcing or heating problems has been found to be quite high (>95%) so we are replacing all 192 seals

• Replacement progress is going well (5 of 6 arcs are done)

• We have also set up motion detectors on 2 dipole chambers

• Many thanks to the hard working members of MFD and MFDV who are making this replacement effort successful!!