status and perspectives of detector arrays of labr3:ce · preliminary results: – digital board...

18
Status and perspectives of detector arrays of LaBr 3 :Ce F. Camera University of Milano INFN sez. of Milano Outline: LaBr 3 :Ce crystal properties R&D on LaBr 3 :Ce The HECTOR + Array Conclusions

Upload: others

Post on 24-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

Status and perspectives of detector

arrays of LaBr3:Ce

F. Camera

University of Milano – INFN sez. of Milano

Outline:

• LaBr3:Ce crystal properties

• R&D on LaBr3:Ce

• The HECTOR+ Array

• Conclusions

Page 2: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

LaBr3:Ce Scintillators

800 900 1000 1100 1200 1300 14000

1

2

3

4

5

BaF2

NaI

arb

. u

nits

Energy (keV)

LaBr3L.Y. 63 ph/keV

Decay Time 16 ns

l 380 nm

N 1.9

r = 5.3 g/cm3

RL (661 keV) 1.9 cm

FWHM

540 ps

60Co

Large Interest in scientific community

• In 2007 more than 40 papers on LaBr3 / LaCl3detectors published in IEEE and NIM

Large Volume

crystal 9x20 cm

are available

Page 3: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

LaBr3 time and energy spectra

Energy resolution: 19 keV at 662 kev FWHM vs g-ray energy

R. Nicolini et al. NIMA 582 (2007) 554–561

Sub-nanosecond time resolution:

Time resolution slightly degrade as crystal

volume increases but :

<L(1”x1”> 10 cm

<L(3”x3”)> 42 cm

<L(3.5”x8”) 120 cm

Large volume detectors guarantee efficiency

for high energy g-rays

152Eu

Page 4: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

Measurements of mono-energetic high energy g-rays

Excellent separation between F.E.P. and 1stE.P.

LaBr3:Ce 3,5”x8”

LaBr3:Ce 3”x3”LaBr3:Ce 3,5”x8”

PuC Source

6.13 MeV Peak

LaBr3:Ce 3”x3”

Page 5: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

660

662

664

666

668

670

672

674

676

678

17 18 19 20 21 22 23

Temperature Voltage Divider

Ba

ric

en

ter

[ke

V]

3' x 3' LaBr3 Photonics XP5300 (700 V)

0.0

2.0

4.0

6.0

8.0

10.0

12.0

14.0

16.0

0 0.5 1 1.5 2

Drift (Volts)D

rift

(k

eV

)

A LaBr3:Ce (crystal + commercial PMT and VD) detector suffers of non linearity for high

energy gamma rays and gain drift due to temperature, HV drift, and count-rate,

DT = 1° DE ~ 2 keV (@ 661 keV)

DV = 0.25 V DE ~ 2 keV (@ 661 keV)

PMT non idealities might affect LaBr3:Ce performances

Non linearity and gain drift due to temperature, HV drift, and count-rate can be monitored,

minimized/corrected with a proper design for voltage divider

- using PMT at low voltage is not the optimal solution.

Page 6: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

New Voltage Divider design

Active Design

• High Linearity 1.8% at 9 MeV

• High Stablility vs Count Rate

• Compact Geometry

Additional board for Temperature, and

High Voltage monitor and LED source

Full test on schedule

A Voltage divider for LaBr3:Ce

At PMT voltage of 800-900 V the

Dynamic range is 0-23 MeV

Page 7: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

New Voltage Divider design

Active Design

A Voltage divider for LaBr3:Ce

At PMT voltage of 800-900 V the

Dynamic range is 0-23 MeV

Spettro LaBr #6 (Tensione 805V)

1

10

100

1000

10000

100000

1000000

-40 1960 3960 5960 7960 9960

Energia [keV]

Co

nteg

gi

Page 8: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

LaBr3:Ce non linearity can be corrected using clever PSA algorithm

NON Linearity correction using PSA techniques

Page 9: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

Preliminary results:

– Digital board prototype for BaF2

– Sampling of LaBr3:Ce signals (1”x1” and 3”x3”) with CAEN VME 2Gs 12 bit board

– Data elaboration in MatLab environment of “direct” signals

• 540 ps timing resolution FWHM

• 2,3 % energy resolution at 1332 keV

– Factor 16 decimation (one sample every 8ns: 125 Ms/sec)

– Optimum FIR Filter

– On-line correction of PMT non linearity & saturation

• 630 ps time resolution FWHM

• 2,3 % energy resolution at 1332 KeV

– Similar results with Struck 100Ms 16 bit

New optimized electronics for LaBr3:Ce

- Digital board especially optimized for LaBr3:Ce-

Page 10: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

• High efficiency portable scintillator detector array

• 8 Large Volume BaF2 Detectors (14 x 17 cm)

• 36 Small Volume BaF2 Detectors

• 10 large Volume LaBr3:Ce detectors ( 9 x 20 cm)

• 8 ready and 2 almost ordered

• It was/will be coupled with

• HPGe arrays - RISING/PRESPEC (GSI) , AGATA (LNL,GSI) …

• Scintillator array – DALI (RIKEN)

• Fragment separators FRS (GSI), BigRIBS (RIKEN), ...

• Charged particle detectors arrays GARFIELD and TRACE (LNL), Si (RIKEN)

HECTOR+ Array

Page 11: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

• Very high background

• Few g transitions

• Extremely rare events

• High energy g-rays

• „Low‟ Budget

• Simple experimental setup

• Easy to transport

Large volume LaBr3:Ce detectors are specific and

unique for the measurement of high energy g-rays.

Performed experiments

- Measurement of g-decay of GQR in inelastic scattering reactions (LNL)

- Measurement of isospin mixing in 90Zr (LNL)

- Measurement if isomer decay in exotic nuclei (RIKEN)

A LaBr3:Ce array, when coupled to a radiation detection system, increases the

efficiency and makes much more powerful the physics program

Page 12: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

Planned experiments:

- October GSI – LAND setup

- November Debrecen (tests)

- December LNL – Agata setup

- 2012 – Riken and GSI (Agata)

A LaBr3:Ce array, when coupled to a radiation detection system, increases the

efficiency and makes much more powerful the physics program

LaBr3:Ce

AGATA

Online ungated spectra

Isospin mixing AGATA+LaBr3:Ce LNL experiment

Page 13: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

8 LaBr3:Ce in barrel configuration

Solid angle covered 12.5 %

Absolute F.E.P. efficiency at 2 MeV 5 %

Absolute F.E.P. efficiency at 10 MeV 1.7 %

10 LaBr3:Ce in standard configuration

Solid angle covered 7.7 %

Absolute F.E.P. efficiency at 2 MeV 3 %

Absolute F.E.P. efficiency at 10 MeV 1 %

Page 14: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

Doppler Broadening Correction

– Position Sensitivity -

• Segmented Photosensor

PSPMT H8500

Silicon Drift Detector pad

• Medical Imaging Techniques

Charge distribution sampling by anode array

Scintillation light flash on photocathode

• Charge PSF

• Image PSF

- Spatial Resolution

- Spatial Linearity

Page 15: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

Measurement in Milano using a collimated source of 137Cs and

a square 5cm x 5cm 1 cm thick CsI + pads of SDD

0 50 100 150

0

20

40

60

80

100

120

0 50 100 150 200 250 3000

50

100

150

200

250

Pixel= 0.2mm

5 mm

Page 16: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

Measurement in Milano using a collimated source of 137Cs and

a cylindrical LaBr3:Ce 3”x3” and a PSPMT

g-rays beam

position

137Cs

Page 17: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

Conclusions• We have started an R&D project concerning LaBr3:Ce for gamma spectroscopy

• The project points to the construction of a trasportable array (HECTOR+) which is

composed of 10 large volume LaBr3:Ce

• The array has already been used in LNL coupled with AGATA and in RIKEN

coupled with CAITEN and clover detectors

• The array has already a tight schedule of experiments in several laboratories

• Even though there are still several technical aspects which remain to be optimized,

LaBr3:Ce gives a fantastic opportunity for all those experiments where

efficiency, time and energy resolution are a key factor

• There are several projects based on LaBr3:Ce detector arrays

- Paris array (Spiral2) See Next Talk

- Shogun (Riken)

- Califa (GSI)

- Darmstadt

- OSLO

Page 18: Status and perspectives of detector arrays of LaBr3:Ce · Preliminary results: – Digital board prototype for BaF 2 – Sampling of LaBr 3:Ce signals (1”x1” and 3”x3”) with

Milano LaBr3:Ce group

N.Blasi, A. Bracco, S. Brambilla, C.Boiano, FC, F.Crespi,

A.Giaz, B.Million, L.Pellegri, S.Riboldi, O. Wieland

F.Birocchi, F.Coniglio

R.Avigo, S.Capra, A.Camplani, S.Ceruti, M.Lafiandra,

R.Nicolini, S.Frega, C.Pairani

Politecnico of Milano

C. Fiorini, R. Peloso, A. Marone , P. Busca