state route 43 (variable width) - brimfield ohio

12
1 2 3 4 5 TALLMADGE ROAD (C. H. 18) (60') STATE ROUTE 43 (VARIABLE WIDTH) DESIGN DEVELOPMENT © 2020 MOODY•NOLAN INC. PRINT DATE: FILE INFO: DRAWING TITLE: FOR DRAWN BY: RJK CHECKED BY: RJK PROGRESS DRAWING NOT FOR CONSTRUCTION 300 SPRUCE STREET SUITE 300 COLUMBUS, OHIO 43215 PHONE: (614) 461-4664 FAX: (614) 280-8881 01/27/2021 Brimfield Fire Station Brimfield Township 1333 Tallmadge Road Brimfield, Ohio 44240 DATE CHANGE DESCRIPTION 20031.00 C1 .00 SITE LAYOUT PLAN 2/25/21

Upload: others

Post on 28-Nov-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

12345

TALLMADGE ROAD (C. H. 18) (60')

STA

TE

RO

UTE

43 (V

AR

IAB

LE

WID

TH

)

DESIGN DEVELOPMENT

© 20

20 M

OODY

•NOL

AN IN

C.PR

INT

DATE

:FI

LE IN

FO:

DRAWING TITLE:

FOR

DRAWN BY: RJK CHECKED BY: RJK

PROGRESSDRAWINGNOT FOR

CONSTRUCTION

300 SPRUCE STREETSUITE 300COLUMBUS, OHIO 43215

PHONE: (614) 461-4664FAX: (614) 280-8881

01/27/2021

Brimfield Fire Station

Brimfield Township

1333 Tallmadge RoadBrimfield, Ohio 44240

DATE CHANGE DESCRIPTION

20031.00

C1.00

SITE LAYOUT PLAN

2/25/21

N

© 20

20 M

OODY

•NOL

AN IN

C.PR

INT

DATE

:FI

LE IN

FO:

DRAWING TITLE:

FOR

DRAWN BY: CHECKED BY:

PROGRESSDRAWINGNOT FOR

CONSTRUCTION

300 SPRUCE STREETSUITE 300COLUMBUS, OHIO 43215

PHONE: (614) 461-4664FAX: (614) 280-8881

19556

2/25//21

Design Development

L100

JS xxx

LANDSCAPE PLAN

Brimfield Fire Station

Brimfield Township

1333 Tallmadge RoadBrimfield, Ohio 44240

# DATE CHANGE DESCRIPTION

KEY VALUE KEYNOTE TEXT

Plant ScheduleKey Qty Botanical / Common Name Size Cond. Spacing

Trees

ACON 8 Abies Concolor/ White Fir 8' B&B see plan

AM 5 Ameliancher g. 'Autumn Brilliance'/ Autumn Brilliance 2" B&B see plan

GB 4 Ginkgo biloba 'Autumn Gold'/ Autumn Gold Ginkgo 1 1/2" #20 see plan

MAG 1 Magnolia x 'Butterflies'/ Butterflies Magnolia 6' No. 5 see plan

MB 5 Magnolia x 'Betty'/ Betty Magnolia 6' clump B&B

PP 7 Picea pungens 'Fastigiata'/ Columnar Blue Spruce 6' B&B see plan

Shrubs

BAP 4 Baptisia x 'Lunar Eclipse'/ Lunar Eclipse False Indigo Clump No. 3 3' O.C.BUX 29 Buxus x. 'Green Velvet'/ Green Velvet Boxwood 18" B&B 3' O.C.

CAL 2 Calycanthus f. 'Athens'/ Athens Sweetshrub 36" No. 5 6' O.C.CL 6 Clethra alnifolia / Summersweet 36" No. 5 4.5' O.C.

DV 39 Diervilla lonicera/ Dwarf Bush Honeysuckle 18" No. 3 3' O.C.

DEU 18 Deutzia g. 'Nikko'/ Dwarf Nikko Deutzia 15" No. 3 2.5' O.C.HQ 13 Hydrangea q. 'Sikes Dwarf'/ Sikes Dwarf Oakleaf Hydrangea 24" No. 5 3' O.C.

HYK 23 Hypericum kalmianum/ Kalm's St. Johnswort 18" No. 3 3' O.C.

HYP 41 Hypericum calycinum/ Aaronsbeard St. Johnswort 6" No. 1 18" O.C.

IT 4 Itea v. 'Henry's Garnet'/ Henry's Garnet Sweetspire 24" No. 3 4' O.C.

ITL 6 Itea v. 'Little Henry'/ Little Henry Dwarf Sweetspire 24" No. 3 3' O.C.

JU 2 Juniperus ch. 'Kally's Compact'/ Kallay's Compact Pfitzer 30" B&B 5' O.C.ROC 1 Rosa 'Carefree Sunshine'/ Carefree Sunshine Rose 24" No. 3 3.5' O.C.

ROS 14 Rosa 'Sunny Knockout'/ Sunny Knockout Rose 18" No. 3 4' O.C.

SP 3 Spirea nipponica 'Snowmound'/ Snowmound Spirea 30" B&B 4' O.C.TX 58 Taxus xm 'Everlow'/ Everlow Yew 18" B&B 3' O.C.

PerennialsECH 31 Echinacea 'Kismet White'/ Kistmet White Echinacea clump No. 1 24" O.C.

GAL 22 Gaillardia 'Arizona Apricot'/ Arizona Apricot Blanket Flower clump No. 1 12" O.C.

IRIS 8 Iris 'Happy Awakening'/ Happy Awakening Iris clump No. 1 24" O.C.

LIA 6 Liatris 'Floristan White'/ Floristan White Gayfeather clump No. 1 18" O.C.

NEP 6 Nepeta x faassenii 'Dropmore'/ Dropmore Catmint clump No. 2 18" O.C.

VER 8 Veronica 'Lavender Lightsaber'/ Lavender Lightsaber Speedwell clump No. 1 18" O.C.

35 Canaliculatus daffodil bulbs bulb 3" O.C.

Brimfield Fire Station2.25.2021DERUlandscape architecture

812 Huron Road E, #411 Cleveland. OH 44115 | 216.466.4355

Overall Plan

Brimfield Fire Station2.25.2021DERUlandscape architecture

812 Huron Road E, #411 Cleveland. OH 44115 | 216.466.4355

Landscape Plan - Addition

Trees

SHRUBS

PERENNIALS

GB - GINKGO

BUX - BOXWOOD

ECH - ECHINACEADEU - DEUTZIA

CL - SUMMERSWEET

IRIS - IRISHQ - HYDRANGEA HYP - AARONSBEARD ST. JOHNSWORT

ROC - ROSE TX - YEW

DV - HONEYSUCKLE

LIA - BLAZING STAR VER - SPEEDWELL HYK - KALMS ST. JOHNSWORT

IT - SWEETSPIRE ROS - KNOCKOUT ROSE

MAG - BUTTERFLIES MAGNOLIA

PP - BLUE SPRUCE

Brimfield Fire Station2.25.2021DERUlandscape architecture

812 Huron Road E, #411 Cleveland. OH 44115 | 216.466.4355

Landscape Plan - Main Building

TREES

SHRUBS

PERENNIALS

AM - SERVICEBERRYACON - WHITE FIR

BUX - BOXWOODBAP - FALSE INDIGO

ECH - ECHINACEA

DEU - DEUTZIA

JU - PFITZER

CAL - SWEETSHRUB

IRIS - IRISTX - YEWSP - SPIREA

DV - HONEYSUCKLE

GAL - BLANKET FLOWER

NEP- CATMINT VER - SPEEDWELL

HYK - KALMS ST. JOHNSWORT

ITL - DWARF SWEETSPIRE

ROS - KNOCKOUT ROSE

GB - GINKGO MB - MAGNOLIA PP - BLUE SPRUCE

RAMP

RAMP

UP

UP

UP

UP

A301

1

A301

2

A302

3

A304

4

A304

2

A304

5

A304

1

A302

1

A302

2

A303

2

A303

1

NEW MEETING ROOM139

RENOVATED OFFICE148

RENOVATED OFFICE149

HALL154

NEW OFFICE152

NEW OFFICE151

ELECTR SERVICE

ROOM134

NEW ENTRY

VESTIBULE147

RENOVATED LOBBY146

STORAGE145

NEW OFFICE150

NEW OFFICE155

NEW OFFICE157

NEW OFFICE158

RENOVATED

OFFICE136

RENOVATED

OFFICE135STORAGE

156

OFFICE160

BREAKROOM161

KITCHENETTE159

EXISTING APPARATUS

BAYS133 TOOL ROOM

130

TURNOUT GEAR132

NEW APPARATUS

BAYS128

EVENT STORAGE129

HOSE TOWER136

WEST STAIRS1-1

ELEV.EL1-1

WATER125

OFFICE126

DINING127

KITCHEN121

WORKOUT ROOM114

MEN'S RR118

WOMEN'S RR119

CONFERENCE110

WORKROOM116

MECHANICAL115 OFFICE

117

FIRE PREV112

FIRE CHIEF106

ASST. FIRE CHIEF104

MAIN ENTRY100EAST STAIR

S2-1

WATCH

OFFICE102

PREV STOR103

STORAGE108

TRIAGE109

LOBBY101

RESTROOM111

CLOSET106A

CLOSET112A

NEW RECPT.

OFFICE153

HALL154

32'-7 1/4" 29'-8" 7'-8 5/8" 43'-6 1/2" 14'-8" 55'-11 1/8" 11'-8" 51'-8" 8'-4 5/8"

ADMINISTRATION

69'-11 7/8"

FIRE STATION

185'-10 1/4"

17

1'-7 5

/8"

15

'-7

3/4

"1

04'-1 1

/2"

A303

3

42

'-8

"1

1'-0

"4

1'-0

"9

'-4 1

/2"

41'-6 1/2" 14'-8" 55'-11 1/8" 9'-7 5/8" 14'-0" 48'-0"

242'-3 5/8"

WOMEN'S RR143

MEN'S RR144

GALLEY KITCHEN141

A302

2

MED ROOM138

100'-0"

96'-6"

STORAGE005

STORAGE004 MECH

003

JAN.002

STORAGE006

STORAGE001

29'-8" 7'-8 5/8"

41

'-3

7/8

"

© 2

020

MO

OD

Y•N

OLA

N IN

C.

PR

INT

DA

TE

:

FIL

E I

NF

O:

DRAWING TITLE:

FOR

DRAWN BY: CHECKED BY:

300 SPRUCE STREET

SUITE 300COLUMBUS, OHIO 43215

PHONE: (614) 461-4664

FAX: (614) 280-8881

2/25

/202

1 5:

00:1

1 P

M

1955

6 B

ri mfie

ld T

owns

hip

Fire

- A

RC

H_d

etac

hed.

rvt

19556

1/27/21

Design Development

A.1

Author Checker

FLOOR PLANS

Brimfield Fire Station

Brimfield Township

1333 Tallmadge RoadBrimfield, Ohio 44240

PLAN3/32" = 1'-0"

LEVEL 01 - SCHEMATIC PLAN2PLAN3/32" = 1'-0"

ADMIN - BASEMENT LEVEL10 12' 18' 24' 30'

# DATE CHANGE DESCRIPTION

2/25/21

UPDN

DN

DN

A301

1

A301

2

A302

3

A304

4

A304

2

A304

5

A304

1

A302

1

A302

2

A303

2

A303

1

OPEN TO BELOW

TRAINING

MEZZANINEM100

GEAR LAUNDRYM101

COMPRESSOR

ROOMM102

TRNG STAIRS3-2

DAYROOM200

EQUIP201

LAUNDRY203

MECHANICAL202

DORM208

OFFICER DORM218

ELEV.EL1-2

WEST STAIRS1-2

LOCKERS209

EAST STAIRS2-2

DORM #7204

DORM #6206

DORM #5207

DORM #4212

DORM #3213

DORM #2215

DORM #1216

14'-8" 55'-11 1/8" 11'-8" 25'-11 1/8"

108'-2 1/4"

14'-8" 55'-11 1/8" 11'-8" 25'-11 1/8"

96

'-8

1/2

"

5'-8 1

/2"

78

'-1

1/4

"1

2'-1

0 3

/4"

A303

3

© 2

020

MO

OD

Y•N

OLA

N IN

C.

PR

INT

DA

TE

:

FIL

E I

NF

O:

DRAWING TITLE:

FOR

DRAWN BY: CHECKED BY:

300 SPRUCE STREET

SUITE 300COLUMBUS, OHIO 43215

PHONE: (614) 461-4664

FAX: (614) 280-8881

2/25

/202

1 5:

00:1

2 P

M

1955

6 B

ri mfie

ld T

owns

hip

Fire

- A

RC

H_d

etac

hed.

rvt

19556

1/27/21

Design Development

A.2

Author Checker

FLOOR PLANS

Brimfield Fire Station

Brimfield Township

1333 Tallmadge RoadBrimfield, Ohio 44240

0 12' 18' 24' 30'

PLAN3/32" = 1'-0"

SECOND FLOOR PLAN1

# DATE CHANGE DESCRIPTION

2/25/21

UP

A301

1

A301

2

A302

3

A304

4

A304

2

A304

5

A304

1

A302

1

A302

2

A303

2

A303

1

STANDING SEAMROOFING SHEET

3" / 12"

3"

/ 1

2"

3" / 12"

3"

/ 1

2"

REMOVE AND REPLACE EXISTING ASPHALT SHINGLE

ROOF , GUTTERS & DOWNSPOUTS. REMOVE & REINSTALL

SOLAR PANELS ON EXISTING BUILDING ROOF.

STANDING SEAMROOFING SHEET

STANDING SEAMROOFING SHEET

STANDING SEAMROOFING SHEET

STANDING SEAMROOFING SHEET

STANDING SEAMROOFING SHEET

MECHANICALLYFASTENED TPO

ROOFING

MECHANICALLYFASTENED TPO

ROOFING

STANDING SEAMROOFING SHEET

MECHANICALLYFASTENED TPOROOFING

GUTTER

GUTTER

GUTTER

GUTTER

GUTTER

GUTTER

GUTTER

GUTTER

GUTTERGUTTER

GUTTER

GUTTER

GUTTER

GUTTER

8" / 12" 8" / 12"

A303

3

3"

/ 12

"3

" /

12

"

3" / 12"

3"

/ 12

"

3"

/ 12

"

3" / 12"3" / 12"

3"

/ 12

"3

" /

12

"

3" / 12"

3" / 12"

3"

/ 12

"

3"

/ 12

"

3" / 12"

3"

/ 1

2"

3" / 12"

© 2

020

MO

OD

Y•N

OLA

N IN

C.

PR

INT

DA

TE

:

FIL

E I

NF

O:

DRAWING TITLE:

FOR

DRAWN BY: CHECKED BY:

300 SPRUCE STREET

SUITE 300COLUMBUS, OHIO 43215

PHONE: (614) 461-4664

FAX: (614) 280-8881

2/25

/202

1 5:

00:1

3 P

M

1955

6 B

ri mfie

ld T

owns

hip

Fire

- A

RC

H_d

etac

hed.

rvt

19556

1/27/21

Design Development

A.3

Author Checker

ROOF PLAN

Brimfield Fire Station

Brimfield Township

1333 Tallmadge RoadBrimfield, Ohio 44240

0 12' 18' 24' 30'

PLAN3/32" = 1'-0"

OVERALL ROOF PLAN1

# DATE CHANGE DESCRIPTION

2/25/21

LEVEL 01 - MAIN LEVEL

100'-0"

ADMIN MAIN LEVEL

103'-6"

ADMIN UPPER LEVEL

104'-8"

LEVEL 00 - LOWER LEVEL

96'-6"

LEVEL 02 - UPPER LEVEL

114'-0"

MEZZANINE

112'-2"

TOWER CMU

148'-0"

38'-7

1/2

" (A

VG

. GR

AD

E T

O T

OP

OF

EA

VE

)

LEVEL 01 - MAIN LEVEL

100'-0"

LEVEL 01 - MAIN LEVEL

100'-0"

ADMIN MAIN LEVEL

103'-6"

ADMIN UPPER LEVEL

104'-8"

LEVEL 00 - LOWER LEVEL

96'-6"

LEVEL 02 - UPPER LEVEL

114'-0"

TOWER CMU

148'-0"

48'-4

" (A

VG

. GR

AD

E T

O T

OP

OF

TR

AIN

ING

TO

WE

R)

2'-5

"

1. REFER TO A700 SERIES FOR WINDOW AND DOOR DETAILS2. REFER TO REFLECTED CEILING PLANS AND EXTERIOR DETAILS FOR

EXTERIOR SOFFIT INFORMATION3. SEE CIVIL / LANDSCAPE DRAWINGS FOR FINISH GRADES4. COORDINATE LOUVER SIZES AND LOCATIONS WITH MECHANICAL.

GENERAL NOTES - EXTERIOR ELEVATIONS

KEYNOTE LEGEND

EXTERIOR GLAZING TYPES

IG-1 EXTERIOR INSULATED GLAZING

IG-1A EXTERIOR INSULATED GLAZING (TEMPERED)

IG-2 EXTERIOR INSULATED GLAZING (TRANSLUCENT)

IG-2A EXTERIOR INSULATED GLAZING (TRANSLUCENT TEMPERED)

IG-3 EXTERIOR INSULATED GLAZING (SPANDREL - LIGHT GRAY)

IG-4 EXTERIOR INSULATED GLAZING (SPANDREL - MEDIUM GRAY)

IG-5 EXTERIOR INSULATED GLAZING (SPANDREL - DARK GRAY)

KEY PLAN

© 2

020

MO

OD

Y•N

OLA

N IN

C.

PR

INT

DA

TE

:

FIL

E I

NF

O:

DRAWING TITLE:

FOR

DRAWN BY: CHECKED BY:

300 SPRUCE STREET

SUITE 300COLUMBUS, OHIO 43215

PHONE: (614) 461-4664

FAX: (614) 280-8881

2/25

/202

1 5:

00:0

0 P

M

1955

6 B

ri mfie

ld T

owns

hip

Fire

- A

RC

H_d

etac

hed.

rvt

19556

1/27/21

Design Development

A301

BH xxx

EXTERIOR ELEVATIONS -OVERALL

Brimfield Fire Station

Brimfield Township

1333 Tallmadge RoadBrimfield, Ohio 44240

ELEVATION3/32" = 1'-0" REF: 1 / A101

WEST - OVERALL1

ELEVATION3/32" = 1'-0" REF: 1 / A101

EAST - OVERALL2

KEY VALUE KEYNOTE TEXT

12

0 12' 18' 24' 30'

0 12' 18' 24' 30'

# DATE CHANGE DESCRIPTION

2/25/21

ADMIN MAIN LEVEL

103'-6"

ADMIN UPPER LEVEL

104'-8"

LEVEL 00 - LOWER LEVEL

96'-6"

6

A402

6

A402

1

A402

1

A402

TOWER CMU

148'-0"

4

A502

W5W5W5

ROOFING SLATES

GUTTER

MINERAL-FIBERCEMENT TRIM

DOWNSPOUT

THIN BRICK VENEER

SEE ELEVATION 4/A304

SF2A720

SF2A720

SF2A720

MINERAL-FIBERCEMENT SIDING

METAL CLAD WOODWINDOWS

STONE VENEER

DOWNSPOUT

FACE BRICK

WATERTABLE BAND

GUTTER

GUTTER

MINERAL-FIBERCEMENT TRIM

FINISH GRADE. SEE CIVIL DWGS

LEVEL 01 - MAIN LEVEL

100'-0"

LEVEL 00 - LOWER LEVEL

96'-6"

LEVEL 02 - UPPER LEVEL

114'-0"

3

A401

3

A401

6

A401

6

A401

2

A401

2

A401

1

A401

1

A401

TOWER CMU

148'-0"4

A401

4

A401

5

A401

5

A401

3

A501

2

A501

2

A302

2

A302

W2 W2W2 W2

W1 W1 W1 W1 W1 W1

SF13A720SF14

A720SF14A720

SF14A720

WATERTABLE BANDSTANDING SEAMROOFING SHEET

MINERAL-FIBERCEMENT TRIM

FOUR FOLD DOORS

DOWNSPOUT

FACE BRICK

WATERTABLE BAND

ALUMINUM WINDOWS

W4

STONE VENEER

STONE VENEER

WATERTABLE BAND

GUTTER

DOWNSPOUT

MINERAL-FIBERCEMENT TRIM

STANDING SEAMROOFING SHEET

FACE BRICK

ALUMINUM WINDOWS

DIMENSIONAL LETTERSIGNAGE

GUTTER

ALUMINUM WINDOWS

FACE BRICK

WATERTABLE BAND

FACE BRICK

38'-7

1/2

"

LEVEL 01 - MAIN LEVEL

100'-0"

ADMIN MAIN LEVEL

103'-6"

ADMIN UPPER LEVEL

104'-8"

LEVEL 00 - LOWER LEVEL

96'-6"

6

A401

6

A401

2

A402

2

A402

1

A401

1

A401

TOWER CMU

148'-0"

3

A501

1

A302

1

A302

SEE ELEVATION 1/A304

W5 W5 W5

STONE VENEERSTONE VENEER

FACE BRICK

DECORATIVE BARN-DOOR STYLE GARAGE DOORS

MINERAL-FIBERCEMENT TRIM

MINERAL-FIBERCEMENT SIDING

MINERAL-FIBERCEMENT TRIM

SECTIONAL OVERHEADDOORS

DOWNSPOUTDOWNSPOUT

MINERAL-FIBERCEMENT TRIM

GUTTER

STANDING SEAMROOFING SHEET

FACE BRICK

WATERTABLE BAND

METAL CLAD WOODWINDOWS

1. REFER TO A700 SERIES FOR WINDOW AND DOOR DETAILS2. REFER TO REFLECTED CEILING PLANS AND EXTERIOR DETAILS FOR

EXTERIOR SOFFIT INFORMATION3. SEE CIVIL / LANDSCAPE DRAWINGS FOR FINISH GRADES4. COORDINATE LOUVER SIZES AND LOCATIONS WITH MECHANICAL.

GENERAL NOTES - EXTERIOR ELEVATIONS

KEYNOTE LEGEND

EXTERIOR GLAZING TYPES

IG-1 EXTERIOR INSULATED GLAZING

IG-1A EXTERIOR INSULATED GLAZING (TEMPERED)

IG-2 EXTERIOR INSULATED GLAZING (TRANSLUCENT)

IG-2A EXTERIOR INSULATED GLAZING (TRANSLUCENT TEMPERED)

IG-3 EXTERIOR INSULATED GLAZING (SPANDREL - LIGHT GRAY)

IG-4 EXTERIOR INSULATED GLAZING (SPANDREL - MEDIUM GRAY)

IG-5 EXTERIOR INSULATED GLAZING (SPANDREL - DARK GRAY)

KEY PLAN

© 2

020

MO

OD

Y•N

OLA

N IN

C.

PR

INT

DA

TE

:

FIL

E I

NF

O:

DRAWING TITLE:

FOR

DRAWN BY: CHECKED BY:

300 SPRUCE STREET

SUITE 300COLUMBUS, OHIO 43215

PHONE: (614) 461-4664

FAX: (614) 280-8881

2/25

/202

1 5:

00:0

4 P

M

1955

6 B

ri mfie

ld T

owns

hip

Fire

- A

RC

H_d

etac

hed.

rvt

19556

1/27/21

Design Development

A302

BH xxx

EXTERIOR ELEVATIONS

Brimfield Fire Station

Brimfield Township

1333 Tallmadge RoadBrimfield, Ohio 44240

ELEVATION1/8" = 1'-0" REF: 1 / A101

NORTH3

ELEVATION1/8" = 1'-0" REF: 1 / A101

WEST - ADDITION1

ELEVATION1/8" = 1'-0" REF: 1 / A101

WEST - RENOVATION2

KEY VALUE KEYNOTE TEXT

04 00 00.B FACE BRICK

04 21 13.A1 THIN BRICK VENEER

04 43 10.A2 WATERTABLE BAND

04 72 00.A6 STONE VENEER

07 31 26.A1 ROOFING SLATES

07 41 13.A1 STANDING SEAM ROOFING SHEET

07 46 46.A1 MINERAL-FIBER CEMENT SIDING

07 46 46.B1 MINERAL-FIBER CEMENT TRIM

07 62 00.A1 GUTTER

07 62 00.D1 DOWNSPOUT

08 35 33 FOUR FOLD DOORS

08 36 13 SECTIONAL OVERHEAD DOORS

08 51 13 ALUMINUM WINDOWS

08 52 13 METAL CLAD WOOD WINDOWS

10 14 19 DIMENSIONAL LETTER SIGNAGE

2 1

3

0 8' 16' 20'12'

0 8' 16' 20'12'

0 8' 16' 20'12'

# DATE CHANGE DESCRIPTION

2/25/21

1. REFER TO A700 SERIES FOR WINDOW AND DOOR DETAILS2. REFER TO REFLECTED CEILING PLANS AND EXTERIOR DETAILS FOR

EXTERIOR SOFFIT INFORMATION3. SEE CIVIL / LANDSCAPE DRAWINGS FOR FINISH GRADES4. COORDINATE LOUVER SIZES AND LOCATIONS WITH MECHANICAL.

GENERAL NOTES - EXTERIOR ELEVATIONS

KEYNOTE LEGEND

EXTERIOR GLAZING TYPES

IG-1 EXTERIOR INSULATED GLAZING

IG-1A EXTERIOR INSULATED GLAZING (TEMPERED)

IG-2 EXTERIOR INSULATED GLAZING (TRANSLUCENT)

IG-2A EXTERIOR INSULATED GLAZING (TRANSLUCENT TEMPERED)

IG-3 EXTERIOR INSULATED GLAZING (SPANDREL - LIGHT GRAY)

IG-4 EXTERIOR INSULATED GLAZING (SPANDREL - MEDIUM GRAY)

IG-5 EXTERIOR INSULATED GLAZING (SPANDREL - DARK GRAY)

LEVEL 01 - MAIN LEVEL

100'-0"

ADMIN MAIN LEVEL

103'-6"

LEVEL 00 - LOWER LEVEL

96'-6"

LEVEL 02 - UPPER LEVEL

114'-0"

TOWER LANDING 4

131'-4"

1

A402

1

A402

TOWER CMU

148'-0"

W4

W3

W1 W1 W1 W1 W1 W1

W3W3W3W3W3W3 W3

SEE ELEVATION 5/A304 SEE 2/A304

W1 W1

STANDING SEAMROOFING SHEET

LIMESTONE EXTERIORVENEER

FACE BRICK

THIN BRICK VENEER

MINERAL-FIBERCEMENT SIDING

DOWNSPOUT

GUTTER

ROOFING SLATES

STONE VENEER

WATERTABLE BAND

GUTTER

MINERAL-FIBERCEMENT TRIM

ALUMINUM WINDOWS

DOWNSPOUT

ALUMINUM WINDOWS

PORCH COLUMN, TYP.STONE VENEER

FACE BRICK

WATERTABLE BAND

DOWNSPOUT

FACE BRICK

GUTTER

MINERAL-FIBERCEMENT TRIM

DOWNSPOUT

ALUMINUM WINDOWS

FACE BRICKMINERAL-FIBERCEMENT TRIM

STANDING SEAMROOFING SHEET

GUTTER

METAL RAILINGS

WALL CAP

HEADER COURSE

ROWLOCK COURSE

HEADER COURSE

FACE BRICK

DOWNSPOUT

LEVEL 01 - MAIN LEVEL

100'-0"

ADMIN MAIN LEVEL

103'-6"

LEVEL 00 - LOWER LEVEL

96'-6"

6

A401

6

A401

2

A402

2

A402

1

A401

1

A401

TOWER LANDING 4

131'-4"

TOWER LANDING 2

118'-6"

TOWER CMU

148'-0"

1

A501

5

A501

3

A501

2

A303

2

A303

SEE ELEVATION 2/A304 SEE 4/A304

FACE BRICK

MINERAL-FIBERCEMENT TRIM

MINERAL-FIBERCEMENT TRIM

STANDING SEAMROOFING SHEET

GUTTER

SECTIONAL OVERHEADDOORS

WATERTABLE BAND

STONE VENEER

LEVEL 01 - MAIN LEVEL

100'-0"

LEVEL 00 - LOWER LEVEL

96'-6"

LEVEL 02 - UPPER LEVEL

114'-0"

3

A401

3

A401

6

A401

6

A401

2

A401

2

A401

1

A401

1

A401

TOWER LANDING 4

131'-4"

TOWER LANDING 2

118'-6"

TOWER CMU

148'-0"4

A401

4

A401

5

A401

1

A501

5

A501

4

A501

6

A501

1

A502

2

A502

1

A303

1

A303

W1 W1 W1 W1 W1 W1

W2 W2 W2 W2

W4

SF14A720

SF14A720

SF14A720

SF1A720

SECTIONAL OVERHEADDOORS

ROWLOCK COURSE

HEADER COURSE

FACE BRICK

METAL RAILINGS

WALL CAP

HEADER COURSE

METAL RAILINGS

METAL RAILINGS

WATERTABLE BANDDOWNSPOUT

STONE VENEER

STANDING SEAMROOFING SHEET

GUTTER

MINERAL-FIBERCEMENT TRIM

DOWNSPOUT

WATERTABLE BAND

STONE VENEER

ALUMINUM WINDOWS

FACE BRICK

WATERTABLE BAND

DOWNSPOUT

STANDING SEAMROOFING SHEET

GUTTER

MINERAL-FIBERCEMENT TRIM

ALUMINUM WINDOWS

DOWNSPOUT

FACE BRICKFACE BRICK

STONE VENEER

MINERAL-FIBERCEMENT TRIM

GUTTER

STANDING SEAMROOFING SHEET

KEY PLAN

© 2

020

MO

OD

Y•N

OLA

N IN

C.

PR

INT

DA

TE

:

FIL

E I

NF

O:

DRAWING TITLE:

FOR

DRAWN BY: CHECKED BY:

300 SPRUCE STREET

SUITE 300COLUMBUS, OHIO 43215

PHONE: (614) 461-4664

FAX: (614) 280-8881

2/25

/202

1 5:

00:0

8 P

M

1955

6 B

ri mfie

ld T

owns

hip

Fire

- A

RC

H_d

etac

hed.

rvt

19556

1/27/21

Design Development

A303

XXX XXX

EXTERIOR ELEVATIONS

Brimfield Fire Station

Brimfield Township

1333 Tallmadge RoadBrimfield, Ohio 44240

KEY VALUE KEYNOTE TEXT

04 00 00.B FACE BRICK

04 00 00.Q1 HEADER COURSE

04 00 00.Q3 ROWLOCK COURSE

04 21 13.A1 THIN BRICK VENEER

04 43 10.A1 LIMESTONE EXTERIOR VENEER

04 43 10.A2 WATERTABLE BAND

04 72 00.A1 WALL CAP

04 72 00.A6 STONE VENEER

05 52 00 METAL RAILINGS

07 31 26.A1 ROOFING SLATES

07 41 13.A1 STANDING SEAM ROOFING SHEET

07 46 46.A1 MINERAL-FIBER CEMENT SIDING

07 46 46.B1 MINERAL-FIBER CEMENT TRIM

07 62 00.A1 GUTTER

07 62 00.D1 DOWNSPOUT

08 36 13 SECTIONAL OVERHEAD DOORS

08 51 13 ALUMINUM WINDOWS

ELEVATION1/8" = 1'-0" REF: 1 / A101

SOUTH3

ELEVATION1/8" = 1'-0" REF: 1 / A101

EAST - RENOVATION1

ELEVATION1/8" = 1'-0" REF: 1 / A101

EAST - ADDITION2

1

3

2

0 8' 16' 20'12'

0 8' 16' 20'12'

0 8' 16' 20'12'

# DATE CHANGE DESCRIPTION

2/25/21

1. REFER TO A700 SERIES FOR WINDOW AND DOOR DETAILS2. REFER TO REFLECTED CEILING PLANS AND EXTERIOR DETAILS FOR

EXTERIOR SOFFIT INFORMATION3. SEE CIVIL / LANDSCAPE DRAWINGS FOR FINISH GRADES4. COORDINATE LOUVER SIZES AND LOCATIONS WITH MECHANICAL.

GENERAL NOTES - EXTERIOR ELEVATIONS

KEYNOTE LEGEND

EXTERIOR GLAZING TYPES

IG-1 EXTERIOR INSULATED GLAZING

IG-1A EXTERIOR INSULATED GLAZING (TEMPERED)

IG-2 EXTERIOR INSULATED GLAZING (TRANSLUCENT)

IG-2A EXTERIOR INSULATED GLAZING (TRANSLUCENT TEMPERED)

IG-3 EXTERIOR INSULATED GLAZING (SPANDREL - LIGHT GRAY)

IG-4 EXTERIOR INSULATED GLAZING (SPANDREL - MEDIUM GRAY)

IG-5 EXTERIOR INSULATED GLAZING (SPANDREL - DARK GRAY)

LEVEL 01 - MAIN LEVEL

100'-0"

ADMIN MAIN LEVEL

103'-6"

LEVEL 00 - LOWER LEVEL

96'-6"

3

A402

3

A402

SF5A720

SF5A720

SF4A720

SF3A720STONE VENEER

WATERTABLE BAND

DOWNSPOUT

FACE BRICK

MINERAL-FIBERCEMENT TRIM

GUTTER

STANDING SEAMROOFING SHEET

MINERAL-FIBERCEMENT TRIM

DOWNSPOUT

GUTTER

STANDING SEAMROOFING SHEET

ADMIN MAIN LEVEL

103'-6"

ADMIN UPPER LEVEL

104'-8"

LEVEL 00 - LOWER LEVEL

96'-6"

4

A402

4

A402

5

A402

5

A402

STANDING SEAMROOFING SHEET

GUTTER

DOWNSPOUTDOWNSPOUT

MINERAL-FIBERCEMENT TRIM

DOWNSPOUT

SF6A720

SF7A720

SF6A720

FACE BRICK

WATERTABLE BAND

STONE VENEER

WOOD FRAMING

GUTTER

MINERAL-FIBERCEMENT TRIM

DOWNSPOUT

FACE BRICK

WATERTABLE BAND

STONE VENEER

DOWNSPOUT

LEVEL 01 - MAIN LEVEL

100'-0"

ADMIN MAIN LEVEL

103'-6"

LEVEL 00 - LOWER LEVEL

96'-6"

3

A402

3

A402

STANDING SEAMROOFING SHEET

GUTTER

DOWNSPOUT

MINERAL-FIBERCEMENT TRIM

WATERTABLE BAND

FACE BRICK

DOWNSPOUT

3'-0

"11

'-4"

1'-0

"

SF8A720

SF8A720

SF8A720

SF11A720

MINERAL-FIBERCEMENT TRIM

STONE VENEER

LEVEL 01 - MAIN LEVEL

100'-0"

ADMIN MAIN LEVEL

103'-6"

LEVEL 00 - LOWER LEVEL

96'-6"

4

A402

4

A402

5

A402

5

A402

3

A502

SF9A720

SF10A720

WATERTABLE BAND

STONE VENEER

MINERAL-FIBERCEMENT TRIM

FACE BRICK

DOWNSPOUT

STANDING SEAMROOFING SHEET

GUTTER

MINERAL-FIBERCEMENT TRIM

DOWNSPOUT

KEY PLAN

© 2

020

MO

OD

Y•N

OLA

N IN

C.

PR

INT

DA

TE

:

FIL

E I

NF

O:

DRAWING TITLE:

FOR

DRAWN BY: CHECKED BY:

300 SPRUCE STREET

SUITE 300COLUMBUS, OHIO 43215

PHONE: (614) 461-4664

FAX: (614) 280-8881

2/25

/202

1 5:

00:1

0 P

M

1955

6 B

ri mfie

ld T

owns

hip

Fire

- A

RC

H_d

etac

hed.

rvt

19556

1/27/21

Design Development

A304

XXX XXX

EXTERIOR ELEVATIONS

Brimfield Fire Station

Brimfield Township

1333 Tallmadge RoadBrimfield, Ohio 44240

KEY VALUE KEYNOTE TEXT

04 00 00.B FACE BRICK

04 43 10.A2 WATERTABLE BAND

04 72 00.A6 STONE VENEER

06 10 00.A2 WOOD FRAMING

07 41 13.A1 STANDING SEAM ROOFING SHEET

07 46 46.B1 MINERAL-FIBER CEMENT TRIM

07 62 00.A1 GUTTER

07 62 00.D1 DOWNSPOUT

ELEVATION1/8" = 1'-0" REF: 1 / A101

PARTIAL WEST ELEVATION1ELEVATION1/8" = 1'-0" REF: 1 / A101

PARTIAL NORTH ELEVATION4

ELEVATION1/8" = 1'-0" REF: 1 / A101

PARTIAL EAST ELEVATION2ELEVATION1/8" = 1'-0" REF: 1 / A101

PARTIAL SOUTH ELEVATION53

1

2

4

0 8' 16' 20'12'

0 8' 16' 20'12'

0 8' 16' 20'12'

0 8' 16' 20'12'

# DATE CHANGE DESCRIPTION

2/25/21