State of the Art Automated Sample Preparation for3-MCPD, MOSH/MOAH, Glyphosate, PEth,
and more…
Oliver Lerch, Ph.D.
GERSTEL GmbH & Co. KG, Muelheim, Germany
![Page 2: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/2.jpg)
GERSTEL History
Founded in 1967 in Muelheim an der Ruhr, Germany (headquarter)
Family owned and operated
Agilent Value Added Reseller (VAR), partnership since 1986
6 subsidiaries, >70 distributors, ~200 employees world-wide
Complete solutions for GC and LC
Sample introduction/thermal desorption
Automated sample preparation
![Page 3: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/3.jpg)
Oliver Lerch, Ph.D.
• At GERSTEL since 2005
• Senior Application Scientist until end of 2019
• Strategic applications
• Presentations on seminars, congresses etc.
• Customer demos & trainings
• Support for R&D
• ...
• Beginning 2020Product Manager Automated Sample Preparation
![Page 4: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/4.jpg)
The Benefits of Automation
Excellent, user independent quality of analytical results
Less tedious and monotonous manual work load in the lab
More time for other important tasks:Data evaluation, method development, quality control etc.
Less exposure to toxic solvents and reagents
![Page 5: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/5.jpg)
MultiPurpose Sampler - MPS
Centrifuge
Weighing Option
Extraction
Derivatization
Heating & Cooling
Solid Phase
Extraction SPE
Dilution Wizard
MultiPosition
Evaporation StationmVAP
quickMIX shakerSID processes
1D/2D barcodes
MPS WorkStation
Filtration
Decapper
![Page 6: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/6.jpg)
MAESTRO Control Software
![Page 7: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/7.jpg)
3-Monochloropropanediol (3-MCPD)and Glycidol in
edible Oils and Fats
![Page 8: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/8.jpg)
Background
3-MCPD, 2-MCPD and glycidol as well as their fatty acid esters are process contaminants in edible oils and fats
Ester cleavage in the digestive tract to form free 3- und 2-MCPD or glycidol respectivelyGlycidol probably carcinogenic for humans3-MCPD carcinogenic in animal testingEU and other countries have established maximum levels for glycidol in fats and oilsMaximum levels for 3-MCPD in preparation
![Page 9: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/9.jpg)
Ester cleavage• Saponification under alkaline conditions
Transformation• Glycidol is converted to 3-MXPD; X=halogen
Removal of matrix• Removal of matrix constituents e.g. fatty acid methyl esters by hexane
extraction
Extraction of analytes• MTBE/ethyl acetate 3/2
Analyte derivatizationEvaporation of extract and reconstitution in isooctaneGC-MS(/MS) analysis
+
“Difference Method”- AOCS Cd 29c-13, DGF C-VI 18 (10), ISO 18363-1
![Page 10: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/10.jpg)
3-MCPD Workstation –Usually integrated with GC-MS(/MS)
![Page 11: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/11.jpg)
5x10
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
0.4
0.45
0.5
0.55
0.6
0.65
0.7
0.75
0.8
0.85
0.9
0.95
1
1.05
1.1
1.15
1.2
1.25
1.3
1.35
1.4
1.45
1.5
1.55
1.6
1.65
1.7
1.75
1.8
1.85
1.9
1.95
2
2.05
+ EIC(198.0, 242.0) SIM 170207-G0504B-01.D
1 2
Counts vs. Acquisition Time (min)12 12.1 12.2 12.3 12.4 12.5 12.6 12.7 12.8 12.9 13 13.1 13.2 13.3 13.4 13.5 13.6 13.7 13.8 13.9 14 14.1 14.2 14.3 14.4 14.5 14.6 14.7 14.8 14.9 15 15.1 15.2 15.3 15.4 15.5 15.6 15.7 15.8 15.9 16 16.1 16.2 16.3 16.4 16.5 16.6 16.7 16.8 16.9 17 17.1 17.2 17.3
2-M
CP
D
3-M
CP
D
3-M
BP
D
Assay A (3-MCPD + glycidol)
Assay B (3-MCPD)
By adding NaBrinstead of NaClglycidol is transformed to 3-MBPD in assay B
Chromatograms
![Page 12: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/12.jpg)
3-MCPD - Summary
„Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF C-VI 18 (10), ISO 18363-1), including evaporation step
24 samples per 24 hours for online GC-MS(/MS) coupling
28 samples per 24 hours for workstation
LOQ for single quadrupole MS (Agilent 5977) depending on matrix 100 µg/kg
LOQ for triple quadrupole MS (Agilent 7010 B) 10 µg/kg for palm oil
Automation for AOCS Cd 29b-13, Cd 29a-13 and Zwagerman/Overman method available
![Page 13: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/13.jpg)
Mineral Oil Saturated Hydrocarbons (MOSH)&
Mineral Oil Aromatic Hydrocarbons (MOAH)
in Foodstuff and Cosmetics
![Page 14: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/14.jpg)
MOSH MOAH
Packaging and printing
Transport, processing and storage
Environmental impact
In cosmetics: Mineral oil containing ingredients
What are MOSH/MOAH andwhat is their Origin?
![Page 15: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/15.jpg)
DIN EN 16995:2017-08 – LC/GC Coupling Sample extract in hexane
Normal phase LC on silica column
Separation in MOSH and MOAH fraction
Direct transfer to retention gap (LC-GC coupling)
Solvent removal via early vapor exit (EVE)
Parallel GC-FID determination of MOSH and MOAH
![Page 16: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/16.jpg)
![Page 17: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/17.jpg)
Steuerung Open Lab übersicht
![Page 18: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/18.jpg)
Data processing Software
GERSTEL Enterprise Edition powered by OpenChrom
Dedicated software for processing of MOSH/MOAH chromatograms
Works with all standard chromatography data formats
Convenient automated signal integration
Separate MOSH and MOAH chromatogram view for a sample
Standardized report
![Page 19: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/19.jpg)
Summary
Automated MOSH/MOAH analysis solution
Dedicated data evaluation software
Automated epoxidation and ALOX cleanup available
Correct results achieved for proficiency test samples:Rice, cheese, chocolate, cocoa butter, fat and facial cream
>40 samples processed per 24 h following the standard method
LODs for dry, water- and fat-containing foodstuff < 0.5 mg/kg
LODs for fats and oils < 2 mg/kg or < 0.5 mg/kg after cleanup and epoxidation
![Page 20: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/20.jpg)
Glyphosate and its Metabolite Aminomethylphosphonic Acid (AMPA)
in Foodstuff
![Page 21: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/21.jpg)
Glyphosate
Most widely used herbicide in the worldStill approved in the EUScientific controversy:Are glyphosate residues in foodstuff carcinogenic?Acceptable Daily Intake EU (ADI) 0.5 mg/kgEU Maximum Residue Levels (MRL) 0.05 to 20 mg/kg• Wheat 10 mg/kg• Corn 1 mg/kg• Rice 0,1 mg/kg• Tea 2 mg/kg• Most fruits and vegetables 0.1 mg/kg• Drinking water 0.1 µg/L
![Page 22: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/22.jpg)
Derivatization
![Page 23: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/23.jpg)
Homogenized sample
10 mL H2O 15 min soaking
Extraction 30 mL 0.1 M HCl 30 min
Centrifugation
5 mL aliquot + 5 mL 0.1 M KOH
200 µL extract + 800 µL H2O
Add borate buffer (pH 9)
FMOC-Cl derivatization reagent
Derivatization at 50°C
Add 2% H3PO4
Inject 1 mL into SPExos
Online SPE cleanup – LC-MS/MS
Manual steps MPS automation
![Page 24: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/24.jpg)
![Page 25: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/25.jpg)
GERSTEL SPExos II
![Page 26: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/26.jpg)
Glyphosate
Glyphosate in wheat
0.1 mg/kg (green); 0.01 mg/kg (magenta)
AMPA in wheat
0.1 mg/kg (red); 0.01 mg/kg (green)
Cereals, corn, soy beans LOQ ~ 0.01 mg/kg MRL = 0.1 mg/kg for fruits and vegetables (higher for tea, cereals etc.)
Soil LOQ ~ 0.01 mg/kg
Water LOQ ~ 10.0 ng/L MRL = 100 ng/L
![Page 27: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/27.jpg)
Summary and Outlook
Analysis systems are used in routine analysis in contract labs since years
Method extensions planned by GERSTEL
• Inclusion of further analytes (e.g. glufosinate)
• Automation of initial extraction, if feasible
• Optimization regarding cleanup and chromatography
![Page 28: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/28.jpg)
Determination of Phosphatidylethanol (PEth) from Dried Blood Spots (DBS) employing
the Dried Blood Spot Autosampler (DBS-A)
![Page 29: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/29.jpg)
Dried Blood Spots (DBS)
Dried Blood Spot = dried blood sample on cellulose card
Defined area = defined blood volume
Simple sampling, shipment, storage and handling
HemaXis DB 10 for accurate and precise volume whole blood sampling and secure shipment worldwide
![Page 30: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/30.jpg)
Dried Blood Spot Autosampler (DBS-A)Head for card handling
LC pump
Columnoven
SPExos
DBS
Head for optional liquid injection –or collection in
workstation mode
MS
MPS
Non-destructive hematocrit measurement on DBS cards with
NIRFlex N-500
![Page 31: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/31.jpg)
A
B
C
Three operation modes
A: OnlineFlow through desorption, online SPE cleanup, LC/MS analysis
B: WorkstationFlow through desorption, online SPE cleanup, collection and optional further sample prep steps
C: WorkstationFlow through desorption, collection and optional further sample prep steps
![Page 32: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/32.jpg)
Phosphatidylethanol (PEth)
Alcohol consumption marker
Proving single alcohol intake possible up to 12 days after consumption
Drivers´ aptitude tests, workplace drug testing
DBS sample matrix is ideal since PEth can be formed and/or degraded in liquid whole blood
Complete online (A) and workstation (B) analysis method will be available soon
![Page 33: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/33.jpg)
Chromatogram spiked Blank Blood
100 ng/mL per analyte
PEth 16:0/18:1
PEth 16:0/18:2
![Page 34: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/34.jpg)
...and more ???
![Page 35: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/35.jpg)
...and more!
Analysis for microplasticsPesticides in water according to EU water framework directivePolyfluoroalkyl substances (PFAS) in waterPCBs in waste oilTHC and metabolites in serum, hair and urineOpioids, cocaine and metabolites in body liquidsFatty acid distribution (FAMES)Mycotoxins in food and feedAcrylamide in brewed coffeePhthalates in consumer products
![Page 36: State of the Art Automated Sample Preparation for 3-MCPD ......3-MCPD - Summary „Sample Prep Solution“: Completely automated sample preparation according to AOCS Cd 29c-13 (DGF](https://reader033.vdocuments.us/reader033/viewer/2022042601/5f62490ab9071527aa7f1aec/html5/thumbnails/36.jpg)
GERSTEL team at analytica 2018
Which application do you wish to automate?