State of Art Power Converters for
Wind/Solar Powered mobile towers
Ram
![Page 2: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/2.jpg)
Bridge between the Source & Load
![Page 3: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/3.jpg)
Present Scenario
DC loads
AC
DC
Charge Controller
MPPT SMPS
rectifiers
DC DC
48 v DC
inverter
AC loads
inverter
![Page 4: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/4.jpg)
Future Scenario
Wind Turbine
Grid/DG
DC Loads
Batteries
Fuel Cells
AC LOADs , Air
Conditioners
Grid Feed
![Page 5: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/5.jpg)
Converters Challenges
Renewable Sources : Stochastic ( Analysed statistically but can never be predicted accurately)
Handling and control of multiple sources ( Wind, Solar,DG, Batteries) Handling of both DC & AC loads Maximizing Renewable energy usage by `prioritizing sources MPPT for PV, Wind and even DG can be explored.
![Page 6: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/6.jpg)
More challenging if Air- conditioners are part of AC loads Batteries key fulcrum and hence ability to manage batteries effectively. Fuel & Health monitoring of batteries Remote Monitoring Bi-directionality for Grid Feed and Smart Grids
Converters Challenges
Converters Challenges - Contd
![Page 7: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/7.jpg)
Features
Efficiency across the load spectrum Full Galvanic Isolation Multi Port Bi-Directionality Reliability and no single point of failure Seamless transfer between sources Max utilization of Renewable Energy Grid feed options & peak load shavings
![Page 8: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/8.jpg)
The future of power conversion
![Page 9: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/9.jpg)
System integration
![Page 10: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/10.jpg)
Trends in Critical Power Backup
![Page 11: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/11.jpg)
Challenge accepted, Google!
![Page 12: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/12.jpg)
![Page 13: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/13.jpg)
What Google requested
Parameter Request
Maximum Power Tested 2000VA
Volume of enclosure 40 in³/655 cm³
Power density 3050W/litre
DC voltage range 399.5 V
AC voltage (RMS) output 240V +/- 12Vac
Efficiency (CEC Method) Min 95 %
Max Temp of Enclosure 60 °C
Ambient T° of test 30 °C
EMI compliance FCC Part 15 B
![Page 14: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/14.jpg)
Google’s Requirement
![Page 15: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/15.jpg)
Result
![Page 16: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/16.jpg)
S M A S u n n y B o y
2 , 5 k W
T S I B r a v o
2 , 0 k W
G o o g l e
r e q u e s t
E f f y
Is it small ?
![Page 17: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/17.jpg)
![Page 18: State of Art Power Converters for Wind/Solar Powered](https://reader033.vdocuments.us/reader033/viewer/2022061002/6299d07ae42dfa37cb40a807/html5/thumbnails/18.jpg)
SMART