standard engineering details & drawings
TRANSCRIPT
![Page 1: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/1.jpg)
Standard Engineering
Details & Drawings
Copyright HercuTech Inc. 12/01/2010 • Patents & Patent Pending • 855.284.4037 • www.HercuTech.com
Issue Date: 11/08/2017
![Page 2: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/2.jpg)
![Page 3: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/3.jpg)
CONFIDENTIALITY and LIABILITY STATEMENT
This publication contains information and data that is not yet available to the public or the general building community at large as it is both preliminary and confidential. We are offering this information to you in order to facilitate your understanding of the advanced HercuWall® construction systems for the purpose of evaluating it for your use. The documents, drawings and construction details contained herein have been prepared by the management of HercuTech Inc. or their Structural Engineers and is being delivered to a select number of parties. The information has been prepared with the utmost care however the Company does not warrant its accuracy for any particular or specific application. The sole purpose of this information is to assist the recipient in deciding the applicability of HercuWall® to recipient’s purpose. BY ACCEPTING THIS DOCUMENT, THE RECIPIENT AGREES AND ACKNOWLEDGES THAT ALL OF THE INFORMATION HEREIN, AND ALL OTHER INFORMATION MADE AVAILABLE TO THE RECIPIENT IN CONNECTION WITH ANY FURTHER STUDY, IS DEEMED TO BE PROPRIETARY AND CONFIDENTIAL INFORMATION OF THE COMPANY AND THAT NONE OF THE INFORMATION SHALL BE USED BY THE RECIPIENT, ITS EMPLOYEES OR REPRESENTATIVES IN ANY MANNER OTHER THAN IN CONNECTION WITH ITS EVALUATION OF THE COMPANY’S PRODUCTS OR TECHNOLOGY FOR THE PURPOSE OF CONSIDERING THEIR USE OR APPLICABILITY. THE COMPANY’S PRODUCTS DESCRIBED HEREIN ARE MANUFACTURED ON EXISTING US AND FOREIGN PATENTS ISSUED AND PENDING. The Company reserves the right to require the return of this document and its collateral information at any time. This document shall remain confidential until such time as the information is made available to the general public or the construction trades at large through the company’s website or by printed copy. This document is fluid and is subject to change or revision, all or in part, without notice. Should you require further technical assistance please contact:
![Page 4: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/4.jpg)
![Page 5: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/5.jpg)
![Page 6: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/6.jpg)
![Page 7: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/7.jpg)
5640 S. 40th St, Suite 5 • Phoenix, AZ 85040
SCALE: N/A
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
DATE OF DRAWING:
11/07/2017UNITS: INCHES
TYPICAL HERCUWALL SECTION
General Notes:
• Typical Interior HercuWall with window and electrical, cutouts to show detail.
HercuWall
Standard Details3D-1
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535SHEET 01 OF 08U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
![Page 8: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/8.jpg)
5640 S. 40th St, Suite 5 • Phoenix, AZ 85040
SCALE: N/ACopyright HercuTech Inc.
12/01/2010
UNITS: INCHES
TYPICAL HERCUWALL SECTION
- BOND BEAM
General Notes:
• 2 #4 rebar in the bond beam placed in hooks pre-installed into ShearStrips at correct dimensions.
• No ties required to hooks, standard lap required where rebar joins.
DATE OF DRAWING:
11/07/2017
HercuWall
Standard Details
PROJECT: N/A
3D-2
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535SHEET 02 OF 08U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
![Page 9: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/9.jpg)
5640 S. 40th St, Suite 5 • Phoenix, AZ 85040
SCALE: N/ACopyright HercuTech Inc.
12/01/2010
UNITS: INCHES
TYPICAL HERCUWALL SECTION
General Notes:
• ShearStrips® have a standard 7/8 inch hole every 3 inches for electrical.
• To install electrical connections or junction boxes remove foam needed from outer 2.5 inch wall.
• Electrical boxes can be fastened to ShearStrips® or can be fastened to concrete studs.
• Nylon grommets are recommended to be used.
• DO NOT cut through ShearStrips®.
DATE OF DRAWING:
11/07/2017
HercuWall
Standard Details
PROJECT: N/A
3D-3
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535SHEET 03 OF 08U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
![Page 10: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/10.jpg)
5640 S. 40th St, Suite 5 • Phoenix, AZ 85040
SCALE: N/ACopyright HercuTech Inc.
12/01/2010
UNITS: INCHES
TYPICAL HERCUWALL SECTION
General Notes:
• 3 inch min. rebar studs will be in footer.
• 9 inch track runs perimeter of wall for installing HercuWall.
• Track is also used to fasten interior and exterior finish.
• See detail 009.
DATE OF DRAWING:
11/07/2017
HercuWall
Standard Details
PROJECT: N/A
3D-4
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535SHEET 04 OF 08U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
![Page 11: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/11.jpg)
5640 S. 40th St, Suite 5 • Phoenix, AZ 85040
SCALE: N/ACopyright HercuTech Inc.
12/01/2010
UNITS: INCHES
TYPICAL HERCUWALL SECTION
General Notes:
• Anchor bolts are embedded in bond beam and used to fasten top plate.
• See detail 010.
DATE OF DRAWING:
11/07/2017
HercuWall
Standard Details
PROJECT: N/A
3D-5
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535SHEET 05 OF 08U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
![Page 12: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/12.jpg)
5640 S. 40th St, Suite 5 • Phoenix, AZ 85040
SCALE: N/ACopyright HercuTech Inc.
12/01/2010
UNITS: INCHES
TYPICAL HERCUWALL SECTION
General Notes:
• Window fastens to concrete surrounding studs.
• Interior finish wraps HercuWall to face of window.
• See detail 012.
DATE OF DRAWING:
11/07/2017
HercuWall
Standard Details
PROJECT: N/A
3D-6
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535SHEET 06 OF 08U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
![Page 13: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/13.jpg)
5640 S. 40th St, Suite 5 • Phoenix, AZ 85040
SCALE: N/ACopyright HercuTech Inc.
12/01/2010
UNITS: INCHES
TYPICAL HERCUWALL SECTION
General Notes:
• Shows concrete studs with no foam or ShearStrips®.
• 4x4 concrete stud placement adjustable up to 12" O.C. spacing
• See detail 004.
DATE OF DRAWING:
11/07/2017
HercuWall
Standard Details
PROJECT: N/A
3D-7
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535SHEET 07 OF 08U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
![Page 14: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/14.jpg)
5640 S. 40th St, Suite 5 • Phoenix, AZ 85040
SCALE: N/ACopyright HercuTech Inc.
12/01/2010
UNITS: INCHES
TYPICAL HERCUWALL SECTION
General Notes:
• Shows standard truss connection.
• See detail 010.
DATE OF DRAWING:
11/07/2017
HercuWall
Standard Details
PROJECT: N/A
3D-8
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535SHEET 08 OF 08U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
![Page 15: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/15.jpg)
SCALE: 3/4" = 12"
Typical HercuWall Section
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
001
![Page 16: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/16.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 1/2" = 12"
Typical HercuWall Elevation
DATE OF DRAWING:
11/07/2017
002
![Page 17: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/17.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 1/2" = 12"
Window Opening at HercuWall
Dropped LintelDATE OF DRAWING:
11/07/2017
004
![Page 18: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/18.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 1/2" = 12"
Window Opening at HercuWall
Flush Lintel
DATE OF DRAWING:
11/07/2017
004.1
![Page 19: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/19.jpg)
SCALE: 1/2" = 12"
Window Opening at HercuWall
Dropped Lintel
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
005
![Page 20: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/20.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 1/2" = 12"
Door Opening at HercuWall
Dropped Lintel
DATE OF DRAWING:
11/07/2017
006
![Page 21: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/21.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 1/2" = 12"
Door Opening at HercuWall
Flush Lintel - ALT.DATE OF DRAWING:
11/07/2017
006.1
![Page 22: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/22.jpg)
SCALE: 1/2" = 12"
Door Opening at HercuWall
Dropped Lintel
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
007
![Page 23: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/23.jpg)
SCALE: 1/2" = 12"
Typical HercuWall Solid Concrete
Shear Wall
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
008
![Page 24: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/24.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 3/4" = 12"
Typical HercuWall at Slab
DATE OF DRAWING:
11/07/2017
009
![Page 25: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/25.jpg)
SCALE: 3/4" = 12"
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
Typical Top of HercuWall
with Strap
DATE OF DRAWING:
11/07/2017
010
![Page 26: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/26.jpg)
SCALE: 3/4" = 12"
Typical HercuWall Jamb Stud
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
011
![Page 27: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/27.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 3/4" = 12"
Typical HercuWall Window Sill
DATE OF DRAWING:
11/07/2017
012
![Page 28: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/28.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 3/4" = 12"
Typical HercuWall Window
Header with Hercutrim
DATE OF DRAWING:
11/07/2017
013
![Page 29: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/29.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 3/4" = 12"
Typical HercuWall to
HercuWall
DATE OF DRAWING:
11/07/2017
015
![Page 30: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/30.jpg)
![Page 31: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/31.jpg)
SCALE: 3/4" = 12"
Typical Slab Edge at Exterior
HercuWall
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
203
![Page 32: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/32.jpg)
SCALE: 3/4" = 12"
Slab Edge at Exterior HercuWall
with Curb
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
204
![Page 33: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/33.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 3/4" = 12"
Interior HercuWall Slab
Elevation Change
DATE OF DRAWING:
11/07/2017
205
![Page 34: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/34.jpg)
SCALE: 3/4" = 12"
Typical Holdown at HercuWall
Shear Wall
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
207
![Page 35: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/35.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 3/4" = 12"
Exterior HercuWall at Slab
Elevation Change
DATE OF DRAWING:
11/07/2017
210
![Page 36: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/36.jpg)
SCALE: 3/4" = 12"
Exterior Finish Termination at
Bottom Exterior HercuWall
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
211
![Page 37: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/37.jpg)
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDINGSCALE: 1 1/2" = 12"
Typical Top of HercuWall with
Truss StrapDATE OF DRAWING:
11/07/2017
300
![Page 38: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/38.jpg)
SCALE: 3/4" = 12"
Typical Floor Truss on
HercuWall - Parallel Truss Strap
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
301
![Page 39: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/39.jpg)
SCALE: 3/4" = 12"
Typical Top of HercuWall with
Truss Saddle
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
302
![Page 40: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/40.jpg)
SCALE: 3/4" = 12"
Typical Top of HercuWall
Hurricane Strap
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
304
![Page 41: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/41.jpg)
Wood Beam at HercuWall
Bond Beam - AB
SCALE: 3/4" = 12"
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
423
![Page 42: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/42.jpg)
Wood Beam at HercuWall
Bond Beam - C
SCALE: 3/4" = 12"
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
424
![Page 43: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/43.jpg)
Wood Beam at HercuWall
Bond Beam - D
SCALE: 3/4" = 12"
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
425
![Page 44: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/44.jpg)
SCALE: 3/4" = 12"
Hambro Joist at Exterior Wall
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
426
![Page 45: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/45.jpg)
SCALE: 3/4" = 12"
Hambro Joist at Interior Bearing
HercuWall
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
427
![Page 46: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/46.jpg)
SCALE: 3/4" = 12"
Hambro Joist Parallel to Exterior
Wall
1720 W. 10th St, Ste. 101 • Tempe, AZ 85281
[email protected] • www.HercuTech.com
1-855-284-4037 • 480-284-4535
PROJECT: N/A
Copyright HercuTech Inc.
12/01/2010
UNITS: INCHES
HercuWall
Standard Details
SHEET 01 OF ##U.S. & INTERNATIONAL PATENTS
& PATENTS PENDING
DATE OF DRAWING:
11/07/2017
428
![Page 47: Standard Engineering Details & Drawings](https://reader030.vdocuments.us/reader030/viewer/2022012915/61c473c2326bdc30ae3f1d01/html5/thumbnails/47.jpg)