staff recommendation - nashville · 119 bowling avenue metro historic zoning commission, may 20,...

17
119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction - addition District: Richland-West End Neighborhood Conservation Zoning Overlay Council District: 24 Map and Parcel Number: 10405028100 Applicant: Preston Quirk, Architect Project Lead: Sean Alexander, [email protected] Description of Project: The applicant proposes to construct a rear addition to an historic house. The addition will be distinguished from the original structures by walls that step in on the sides, and by the roof of the addition being shorter than the original roof. Recommendation Summary: Staff recommends approval of the proposed addition, with the condition that staff approves the final selection of windows and doors, finding the proposal to meet the design guidelines for additions in the Richland-West End Neighborhood Conservation Zoning Overlay. Attachments A: Photographs B: Site Plan C: Elevations

Upload: others

Post on 18-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1

STAFF RECOMMENDATION

119 Bowling Avenue

May 20, 2015

Application: New construction - addition

District: Richland-West End Neighborhood Conservation Zoning Overlay

Council District: 24

Map and Parcel Number: 10405028100

Applicant: Preston Quirk, Architect

Project Lead: Sean Alexander, [email protected]

Description of Project: The applicant proposes to construct a rear

addition to an historic house. The addition will be distinguished

from the original structures by walls that step in on the sides, and

by the roof of the addition being shorter than the original roof.

Recommendation Summary: Staff recommends approval of the

proposed addition, with the condition that staff approves the final

selection of windows and doors, finding the proposal to meet the

design guidelines for additions in the Richland-West End

Neighborhood Conservation Zoning Overlay.

Attachments

A: Photographs

B: Site Plan

C: Elevations

Page 2: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 2

Vicinity Map:

Aerial Map:

Page 3: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 3

Applicable Design Guidelines:

II.B.1 New Construction a. Height

The height of the foundation wall, porch roof(s), and main roof(s) of a new building shall be compatible, by

not contrasting greatly, with those of surrounding historic buildings.

b. Scale

The size of a new building and its mass in relation to open spaces shall be compatible, by not contrasting

greatly, with surrounding historic buildings.

Foundation lines should be visually distinct from the predominant exterior wall material. This is typically

accomplished with a change in material.

c. Setback and Rhythm of Spacing

The setback from front and side yard property lines established by adjacent historic buildings should be

maintained. Generally, a dominant rhythm along a street is established by uniform lot and building

width. Infill buildings should maintain that rhythm.

d. Materials, Texture, Details, and Material Color

The materials, texture, details, and material color of a new building's public facades shall be visually

compatible, by not contrasting greatly, with surrounding historic buildings. Vinyl and aluminum siding

are not appropriate.

T-1-11- type building panels, "permastone", E.F.I.S. and other artificial siding materials are generally not

appropriate. However, pre-cast stone and cement fiberboard siding are approvable cladding materials

for new construction; but pre-cast stone should be of a compatible color and texture to existing historic

stone clad structures in the district; and cement fiberboard siding, when used for lapped siding, should

be smooth and not stamped or embossed and have a maximum of a 5” reveal.

Shingle siding should exhibit a straight-line course pattern and exhibit a maximum exposure of seven

inches (7”).

Four inch (4”) nominal corner boards are required at the face of each exposed corner.

Stud wall lumber and embossed wood grain are prohibited.

Belt courses or a change in materials from one story to another are often encouraged for large two-story

buildings to break up the massing.

When different materials are used, it is most appropriate to have the change happen at floor lines.

Clapboard sided chimneys are generally not appropriate. Masonry or stucco is appropriate.

Texture and tooling of mortar on new construction should be similar to historic examples.

Asphalt shingle is an appropriate roof material for most buildings. Generally, roofing should not have

strong simulated shadows in the granule colors which results in a rough, pitted appearance; faux

shadow lines; strongly variegated colors; colors that are too light (e.g.: tan, white, light green); wavy

or deep color/texture used to simulate split shake shingles or slate; excessive flared form in the shingle

tabs; uneven or sculpted bottom edges that emphasize tab width or edges, unless matching the original

roof.

Generally front doors should be 1/2 to full-light. Faux leaded glass is inappropriate.

e. Roof Shape

The roof(s) of a new building shall be visually compatible, by not contrasting greatly, with the roof shape,

orientation, and pitch of surrounding historic buildings.

Roof pitches should be similar to the pitches found in the district. Historic roofs are generally between 6/12

Page 4: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 4

and 12/12.

Roof pitches for porch roofs are typically less steep, approximately in the 3-4/12 range.

Generally, two-story residential buildings have hipped roofs.

Generally, dormers should be located on the roof. Wall dormers are not typical in the historic context and

accentuate height so they should be used minimally and generally only on secondary facades. When they

are appropriate they should be no wider than the typical window openings and should not project beyond

the main wall.

f. Orientation

The orientation of a new building's front facade shall be visually consistent with surrounding historic

buildings.

Parking areas and Driveways

Generally, curb cuts should not be added.

Where a new driveway is appropriate it should be two concrete strips with a central grassy median.

Shared driveways should be a single lane, not just two driveways next to each other. Sometimes this may

be accomplished with a single lane curb cut that widens to a double lane deeper into the lot.

g. Proportion and Rhythm of Openings

The relationship of width to height of windows and doors, and the rhythm of solids (walls) to voids (door

and window openings) in a new building shall be compatible, by not contrasting greatly, with

surrounding historic buildings.

Window openings on the primary street-related or front façade of new construction should be

representative of the window patterns of similarly massed historic structures within the district.

In most cases, every 8-13 horizontal feet of flat wall surface should have an opening (window or door) of at

least 4 square feet. More leniencies can be given to minimally visible side or rear walls.

Double-hung windows should exhibit a height to width ratio of at least 2:1.

Windows on upper floors should not be taller than windows on the main floor since historically first floors

have higher ceilings than upper floors and so windows were typically taller on the first floor.

Single-light sashes are appropriate for new construction. If using multi-light sashes, muntins should be

fully simulated and bonded to the glass, and exhibit an interior bar, exterior bar, as well as a spacer

between glass panes.

Four inch (nominal) casings are required around doors, windows and vents on non-masonry buildings.

Trim should be thick enough to extend beyond the clapboard. Double or triple windows should have a

4” to 6” mullion in between.

Brick molding is required around doors, windows and vents within masonry walls but is not appropriate on

non-masonry buildings.

h. Outbuildings

(Although the MHZC does not review use itself there are additional ordinance requirements for buildings

that are or have a Detached Accessory Dwelling Unit (DADU) required by ordinance 17.16.030 that are

reviewed by the MHZC. This information is provided for informational purposes only and does not replace

ordinance 17.16.030.)

1) A new garage or storage building should reflect the character of the period of the house to which the

outbuilding will be related. The outbuilding should be compatible, by not contrasting greatly, with

surrounding historic outbuildings in terms of height, scale, roof shape, materials, texture, and details.

2) Outbuildings should be situated on a lot as is historically typical for surrounding historic buildings.

Generally new garages should be placed close to the alley, at the rear of the lot, or in the original location

of an historic accessory structure.

Page 5: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 5

Lots without rear alleys may have garages located closer to the primary structure. The appropriate

location is one that matches the neighborhood or can be documented by historic maps.

Generally, attached garages are not appropriate; however, instances where they may be are:

· Where they are a typical feature of the neighborhood; or

· When the location of the attached garage is in the general location of an historic accessory building,

the new garage is located in the basement level, and the vehicular access is on the rear elevation.

i. Utilities

Utility connections such as gas meters, electric meters, phone, cable, and HVAC condenser units should be

located so as to minimize their visibility from the street.

Generally, utility connections should be placed no closer to the street than the mid point of the structure.

Power lines should be placed underground if they are carried from the street and not from the rear or

an alley.

2. ADDITIONS

a. Generally, an addition should be situated at the rear of a building in such a way that it will not disturb

either front or side facades.

Placement

Additions should be located at the rear of an existing structure.

Connections to additions should, as much as possible, use existing window and door openings rather

than remove significant amounts of rear wall material.

Generally, one-story rear additions should inset one foot, for each story, from the side wall.

Additions should be physically distinguished from the historic building and generally fit within the

shadow line of the existing building.

When an addition ties into the existing roof, the addition should be at least 6” below the existing ridge.

In order to assure than an addition has achieved proper scale, the addition should:

· No matter its use, an addition should not be larger than the existing house, not including non-historic

additions, in order to achieve compatibility in scale. This will allow for the retention of small and

medium size homes in the neighborhood. The diversity of housing type and size is a character

defining feature of the historic districts.

· Additions which are essentially a house-behind-a-house with a long narrow connector are not

appropriate, as the form does not exist historically. Short or minimal connections that do not

require the removal of the entire back wall of a historic building are preferred.

· Additions should generally be shorter and thinner than the existing building. Exceptions may be

made when unusual constraints make these parameters unreasonable, such as:

· An extreme grade change

· Atypical lot parcel shape or size

In these cases, an addition may rise above or extend wider than the existing building; however,

generally the addition should not higher and extend wider.

Foundation

Foundation walls should set in from the existing foundation at the back edge of the existing structure

by one foot for each story or half story. Exception: When an addition is a small one-room deep

(12’ deep or less) addition that spans the width of the structure, and the existing structure is

masonry with the addition to be wood (or appropriate substitute siding). The change in

material from masonry to wood allows for a minimum of a four inch (4”) inset.

Foundation height should match or be lower than the existing structure.

Page 6: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 6

Foundation lines should be visually distinct from the predominant exterior wall material. This is

generally accomplished with a change in materials.

Roof

The height of the addition's roof and eaves must be less than or equal to the existing structure.

Visually evident roof slopes should match the roof slopes of the existing structure, and roof planes

should set in accordingly for rear additions.

Skylights should not be located on the front-facing slope of the roof. Skylights should be flat (no bubble

lenses) with a low profile (no more than six inches tall) and only be installed behind the midpoint

of the building).

b. The creation of an addition through enclosure of a front porch is not appropriate.

The addition should set back from the face of the historic structure (at or beyond the midpoint of the

building) and should be subservient in height, width and massing to the historic structure.

Side additions should be narrower than half of the historic building width and exhibit a height of at least

2’ shorter than the historic building.

To deemphasize a side addition, the roofing form should generally be a hip or side-gable roof form.

c. Contemporary designs for additions to existing properties are not discouraged when such additions do not

destroy significant historical, architectural, or cultural material; and when such design is compatible, by not

contrasting greatly, with the size, scale, color, material, and character of the property, neighborhood, or

environment.

Side porch additions may be appropriate for corner building lots or lots more than 60’ wide.

d. A new addition should be constructed in such a manner that if the addition were to be removed in the

future, the essential form and integrity of the original structure would be unimpaired.

e. Additions should follow the guidelines for new construction.

Connections should, as much as possible, use existing window and door openings rather than remove

significant amounts of rear wall material.

Page 7: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 7

Background: 119 Bowling Avenue is a one and one-half story Craftsman house, with a

side gabled roof and a full-width front porch. The house was built circa 1925, and

contributes to the historic character of the area because of its age and architectural style.

Analysis and Findings: The applicant proposes to enlarge the house with a rear addition

that includes an attached basement-level garage.

Height & Scale:

The addition will tie into the rear slope of the existing roof six inches (6”) below the

ridge, and extend out to the rear with a rear-facing gable. The floor height and eaves of

the addition will align with their counterparts on the original structure, and a portion of an

original lower eave at the rear will be retained. The walls of the addition will sit in two

feet (2’) from the sides of the existing house, extending back four feet (4’) before

stepping out to match the original width. After this stepped-in section the addition will

extend back another twenty feet (20’). Lastly, a nine-foot (9’) deep screened porch will

be at the very rear of the addition. Including the rear porch, at thirty-three feet (33’) the

depth of the addition is roughly half the depth of the original structure. Staff finds the

height and scale of the addition to be compatible with the historic house and to meet

sections II.B.2.a and II.B.2.e of the design guidelines.

Location & Removability:

With the addition distinguished from the existing structure by the stepped-in walls and

then matching the width of the house, and with the new roof sitting six inches (6”) below

the existing ridge, the addition will not have a negative or irreversible impact on the form

and character of the original structure. Staff finds the addition to meet sections II.B.2.a

and II.B.2.d of the design guidelines.

Design:

The addition will have a rear-facing gabled roof, a form that is compatible with the side-

gabled roof of the existing building. Both sides of the new gable will have shed dormers,

stepped back two feet (2’) from the first-story walls below, as is typical of historic

dormers. The proportion and rhythm of windows will be compatible with the existing

building as well. Staff finds that the project meets section II.B.2.a and e.

Setback:

The addition will meet all setback requirements. The project meets section II.B.1.c

Materials:

The siding on the existing structure will be replaced with smooth-faced cement-

fiberboard, matching the exposure profile of the existing siding. No other changes to the

historic house’s materials were indicated on the drawings. Although removal of the

siding, windows, and roof on an historic house simultaneously is tantamount to

demolition, the replacement of a single item is not prohibited in a Neighborhood

Conservation Zoning Overlay.

Page 8: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 8

The addition will be clad in smooth-faced cement fiberboard with a reveal matching that

of the historic house with matching cement-fiberboard trim. The foundation of the

addition will be split-faced concrete block, and the roof will be architectural fiberglass

shingles matching the color of the existing roof. There will be a brick veneered chimney

on the left side of the addition. The rear porch and stairs will be wood, and the windows

and doors of the addition will be wood or composite. Staff asks to approve the final

window and door selections prior to purchase and installation. The project meets section

II.B.1.d

Proportion and Rhythm of Openings:

No changes to the window and door openings on the existing house were indicated on the

plans. The windows on the proposed addition are all generally twice as tall as they are

wide, thereby meeting the historic proportions of openings. There are no large expanses

of wall space without a window or door opening. Staff finds the project’s proportion and

rhythm of openings to meet Section II.B.1.g.

Appurtenances & Utilities: No changes to the site’s appurtenances were indicated on the

drawings. The location of the HVAC and other utilities was also not noted. Staff asks

that the HVAC be located on the rear façade, or on a side façade beyond the midpoint of

the house. Meeting this condition, staff finds that the project meets section II.B.1.i.

Outbuildings: The proposal also includes a basement-level attached garage below the

addition, accessed from the alley to the rear. In this location, an attached garage is

compatible with the location of historic garages. In the past, the Commission has found

attached garages to be appropriate if they are full at the basement level and accessed from

the rear, as this one is. Staff finds that the project meets section II.B.1.h of the design

guidelines.

Recommendation: Staff recommends approval of the proposed addition, with the

condition that staff approves the final selection of windows and doors, finding the

proposal to meet the design guidelines for additions in the Richland-West End

Neighborhood Conservation Zoning Overlay.

Page 9: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 9

119 Bowling Avenue, front.

119 Bowling Avenue, right.

Page 10: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 10

119 Bowling Avenue, rear.

Page 11: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

2931

BE

RR

Y H

ILL

DR

IVE

SU

ITE

200

NA

SH

VIL

LE, T

N 3

7204

Pho

ne: (

615)

269

-924

8 Fa

x: (6

15) 6

27-1

298

emai

l: qu

irkde

sign

s@co

mca

st.n

etQ

UIR

K D

ES

IGN

S

PHONE:W335-0732H298-1508

REVISION

PROJECT NO:

COPYRIGHT 2007QUIRK DESIGNS

SHEET 1

C1

/CA

DD

FIL

ES

/Wor

k 20

15/m

itche

ll 11

7 bo

wlin

g 15

-035

/117

c.p

ln

Bon

nie

Mitc

hell

119

Bow

ling

Ave

Nas

hvill

e, ,

TN 3

7205

SITE PLAN

Add

ition

to R

esid

ence

15-035

DATE: 5/5/15

W8

5'-9

" by

5'-4

"W

85'

-9" b

y5'

-4"

D38

3' b

y7'

W12'-8" by3'-8"

W88' by5'-10"

W12'-8" by3'-8"

W22'-8" by3'-8"

W3

3' b

y5'

-4"

W4

3' b

y5'

-4"

D35

4' b

y8'

D34

5' b

y6'

-8"

D353' by8' D36

3' by7'

W32'-8" by5'-4"

W42'-8" by5'-4"

D363' by8'

W22'-8" by5'-4"

W32'-8" by5'-4"

W42'-8" by5'-4"

W22'-8" by3'-8"

W32'-8" by3'-8"

D358' by7'

D36

3' b

y8'

D34

3' b

y8'

D34

3' b

y6'

-8"

D372'-8" by8'

D38

12' b

y8'

D37

2'-8

" by

8'

D372'-6" by8'

W22'-8" by3'-6"

W22'-8" by5'-4"

W22'-8" by3'-6"

W85'-9" by5'-4"

W53' by3'

W63' by3'

D37

2'-8

" by

8'

D37

2'-8

" by

8'

N

DW

2 A72 A7

#Drg

ID#L

ayID

#Drg

ID#L

ayID

3 1/

2"13

'-0"

3 1/

2"5'

-7 1

/2"

3 1/

2"6'

-7"

3 1/

2"7'

-2 1

/2"

3 1/

2"

16'-0

1/2

"7"

16'-8

"3

1/2"

9'-5"13'-5 1/2"3 1/2"13'-6 1/2"3 1/2"7'-5"3 1/2"13'-3"4'-3"3 1/2"19'-0"3 1/2"

3 1/2"47'-5"3 1/2"21'-1"3 1/2"

48'-6 1/2"23'-10"

3 1/

2"33

'-3 1

/2"

3 1/

2"

10'-3

1/2

"3

1/2"

8'-7

1/2

"3

1/2"

12'-1

"3

1/2"

2'-0

"

14'-9

1/2

"3

1/2"

18'-9

"

33'-1

0 1/

2"

18'-0

1/2

"3

1/2"

14'-1

1 1/

2"3

1/2"

3 1/

2"3'

-2"

3 1/

2"6'

-6 1

/2"

9'-5"13'-5 1/2"3 1/2"18'-11"3 1/2"15'-7"12'-0"18'-0"

4'-2

1/2

"3

1/2"

18'-9

"

10'-0

"

#Drg

ID#L

ayID

#Drg

ID#L

ayID

1 A7

1 A7

#Drg

ID#L

ayID

#Drg

ID#L

ayID

3

2

4

open

rail

& b

alus

ters

SIL

T FE

NC

ING

linen

rang

e

DR

IVE

UN

DE

RP

OR

CH

INTO

BS

MT

GA

RA

GE

woo

dbur

ning

fire

plac

e

FFE

542

+/-

BS

MT

FFE

BE

LOW

532.

0 +/

-

Stud

y

M c

lose

t

M b

ath

Mst

r B

edrm

bfas

t are

a

Fam

ily R

m

Scre

ened

por

ch

ALL

EY

BO

WLI

NG

AV

ENU

E

Din

ing

Rm

updnEX

ISTI

NG

HO

USE

NEW

AD

DIT

ION

dn 1

6"3

r @

5.3

3"2

t @ 1

1"

up

DR

AIN

AG

E

ref

EXIS

TIN

G G

AR

AG

E

UP

Stud

y

clos

et

pant

ry

Livi

ng R

m/F

oyer

stac

kw

/d

bar

54053

8

536

534

532

530

Addition 1st flr

4A

: 967

.66

sq ft

1st flr existing

5A

: 1,4

21.4

2 sq

ft

3 A7

3 A7

4 A7

4 A7

77

88

5 A75 A7

1010

chr

chF

3 1/

2"14

'-11

1/2"

3 1/

2"3'

-8"

3 1/

2"1'

-6"

4'-1

"3'

-0"

5'-6

"3

1/2"

D35

4' b

y8'

SC

ALE

: 1"

= 2

0'1

SIT

E P

LAN

NEW 1.5 STORYADDITION

EXISTING HOUSE

pervious patioover 6" gravelbed

Page 12: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

2931

BE

RR

Y H

ILL

DR

IVE

SU

ITE

200

NA

SH

VIL

LE, T

N 3

7204

Pho

ne: (

615)

269

-924

8 Fa

x: (6

15) 6

27-1

298

emai

l: qu

irkde

sign

s@co

mca

st.n

etQ

UIR

K D

ES

IGN

S

PHONE:W335-0732H298-1508

REVISION

PROJECT NO:

COPYRIGHT 2007QUIRK DESIGNS

SHEET 2

A1

/CA

DD

FIL

ES

/Wor

k 20

15/m

itche

ll 11

7 bo

wlin

g 15

-035

/117

c.p

ln

Bon

nie

Mitc

hell

119

Bow

ling

Ave

Nas

hvill

e, ,

TN 3

7205

1ST FLOOR PLAN

Add

ition

to R

esid

ence

15-035

DATE: 5/5/15

W8

5'-9

" by

5'-4

"W

85'

-9" b

y5'

-4"

D38

3' b

y7'

W12'-8" by3'-8"

W88' by5'-10"

W12'-8" by3'-8"

W22'-8" by3'-8"

W3

3' b

y5'

-4"

W4

3' b

y5'

-4"

D35

4' b

y8'

D34

5' b

y6'

-8"

D353' by8' D36

3' by7'

W32'-8" by5'-4"

W42'-8" by5'-4"

D363' by8'

W22'-8" by5'-4"

W32'-8" by5'-4"

W42'-8" by5'-4"

W22'-8" by3'-8"

W32'-8" by3'-8"

D358' by7'

D36

3' b

y8'

D34

3' b

y8'

D34

3' b

y6'

-8"

D372'-8" by8'

D38

12' b

y8'

D37

2'-8

" by

8'

D372'-6" by8'

W22'-8" by3'-6"

W22'-8" by5'-4"

W22'-8" by3'-6"

W85'-9" by5'-4"

W53' by3'

W63' by3'

D37

2'-8

" by

8'

D37

2'-8

" by

8'

DW

2 A72 A7

#Drg

ID#L

ayID

#Drg

ID#L

ayID

3 1/

2"13

'-0"

3 1/

2"5'

-7 1

/2"

3 1/

2"6'

-7"

3 1/

2"7'

-2 1

/2"

3 1/

2"

16'-0

1/2

"7"

16'-8

"3

1/2"

9'-5"13'-5 1/2"3 1/2"13'-6 1/2"3 1/2"7'-5"3 1/2"13'-3"4'-3"3 1/2"19'-0"3 1/2"

3 1/2"47'-5"3 1/2"21'-1"3 1/2"

48'-6 1/2"23'-10"

3 1/

2"33

'-3 1

/2"

3 1/

2"

10'-3

1/2

"3

1/2"

8'-7

1/2

"3

1/2"

12'-1

"3

1/2"

2'-0

"

14'-9

1/2

"3

1/2"

18'-9

"

33'-1

0 1/

2"

18'-0

1/2

"3

1/2"

14'-1

1 1/

2"3

1/2"

3 1/

2"3'

-2"

3 1/

2"6'

-6 1

/2"

9'-5"13'-5 1/2"3 1/2"18'-11"3 1/2"15'-7"12'-0"18'-0"

4'-2

1/2

"3

1/2"

18'-9

"

#Drg

ID#L

ayID

#Drg

ID#L

ayID

1 A7

1 A7

#Drg

ID#L

ayID

#Drg

ID#L

ayID

open

rail

& b

alus

ters

SIL

T FE

NC

ING

linen

rang

e

DR

IVE

UN

DE

RP

OR

CH

INTO

BS

MT

GA

RA

GE

woo

dbur

ning

fire

plac

e

FFE

542

+/-

BS

MT

FFE

BE

LOW

532.

0 +/

-

Stud

y

M c

lose

t

M b

ath

Mst

r B

edrm

bfas

t are

a

Fam

ily R

m

Scre

ened

por

ch

Din

ing

Rm

updnEX

ISTI

NG

HO

USE

NEW

AD

DIT

ION

dn 1

6"3

r @

5.3

3"2

t @ 1

1"

up

ref

Stud

y

clos

et

pant

ry

Livi

ng R

m/F

oyer

stac

kw

/d

bar

54053

8

536

534

Addition 1st flr

4A

: 967

.66

sq ft

1st flr existing

5A

: 1,4

21.4

2 sq

ft

3 A7

3 A7

4 A7

4 A7

3 1/

2"14

'-11

1/2"

3 1/

2"3'

-8"

3 1/

2"1'

-6"

4'-1

"3'

-0"

5'-6

"3

1/2"

D35

4' b

y8'

SC

ALE

: 1"

= 1

0'1

1ST

FLO

OR

PLA

N

NOTE TO CONTRACTOR & OWNER:THIS PROJECT WILL BE INSPECTED BYMETRO HISTORICAL (MHC).CHANGES THAT AFFECT THE ELEVATIONSOR SECTIONS IN ANY WAY SHALL NOT BE MADE,UNLESS APPROVED BY ARCHITECT AND MHC.

Page 13: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

2931

BE

RR

Y H

ILL

DR

IVE

SU

ITE

200

NA

SH

VIL

LE, T

N 3

7204

Pho

ne: (

615)

269

-924

8 Fa

x: (6

15) 6

27-1

298

emai

l: qu

irkde

sign

s@co

mca

st.n

etQ

UIR

K D

ES

IGN

S

PHONE:W335-0732H298-1508

REVISION

PROJECT NO:

COPYRIGHT 2007QUIRK DESIGNS

SHEET 3

A2

/CA

DD

FIL

ES

/Wor

k 20

15/m

itche

ll 11

7 bo

wlin

g 15

-035

/117

c.p

ln

Bon

nie

Mitc

hell

119

Bow

ling

Ave

Nas

hvill

e, ,

TN 3

7205

2ND FLR PLAN

Add

ition

to R

esid

ence

15-035

DATE: 5/5/15

W22

3'-4

" by

2'W

222'

-8" b

y2'

W23

2'-8

" by

2'

W25

8' b

y4'

W22'-9" by4'-3"

W22'-9" by4'-3"

W223' by2'

W223' by2'

W22'-9" by4'-3"

W248' by4'-6"

D33

2'-4

" by

6'-8

"

D332'-8" by6'-8"

D33

2'-4

" by

6'-8

"D33

2'-4" by6'D332'-4" by6'-8"

D332'-4" by6'-8"

D332'-8" by6'-8"

D33

2'-4

" by

6'-8

"

D332'-8" by6'-8"

D332'-8" by5'-6"

D33

2'-8

" by

6'-8

"

2 A72 A7

#Drg

ID#L

ayID

#Drg

ID#L

ayID

#Drg

ID#L

ayID

1 A7

A7

#Drg

ID#L

ayID

#Drg

ID#L

ayID

3 1/

2"14

'-1 1

/2"

3 1/

2"

3 1/2"38'-0"

12'-2

"9'

-3"

12'-2

"

41'-7 1/2"

3 1/2"8'-2"12'-1"

4'-10 1/2"

3 1/

2"14

'-11

1/2"

3 1/2"20'-5"3 1/2"6'-11 1/2"3 1/2"5'-4 1/2"

3 1/2"11'-6"3 1/2"13'-0"3 1/2"

3 1/

2"10

'-10"

3 1/

2"3'

-7"

3 1/2"14'-2"3'-11 1/2"17'-3 1/2"3 1/2"2'-0"3 1/2"

3 1/

2"13

'-6"

3 1/

2"8'

-9 1

/2"

3 1/

2"

3 1/

2"27

'-7 1

/2"

5'-8

"3

1/2"

10'-1

"3

1/2"

7'-1

1 1/

2"3

1/2"

3'-9

1/2

"3

1/2"

10'-1

0"

2'-0

"

3 A7

4 A7

86"

HIG

H W

ALL

58" H

IGH

WA

LL

36" h

igh

wal

lw

/woo

d ca

p7' h

igh

wal

l

slop

ed c

lg

58" H

IGH

WA

LL

5' W

ALL

58" H

IGH

WA

LL

flush

rafte

r sup

port

beam

(new

)

PLAY

RM

dn

ATTI

C3/

4" P

LYW

D F

LR

bedr

m 3

bedr

m 4

clos

4

Bed

rm 2

Clo

s 3

bath

2

clos

2

clos

3

bath

3

bath

4

PLAY

RM

Laun

dry

rm

attic

2nd flr

5A

: 1,5

51.6

9 sq

ft

D332'-4" by6'-8"

SC

ALE

: 1/8

" =

1

'-0"

12N

D F

LR P

LAN

Page 14: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

2931

BE

RR

Y H

ILL

DR

IVE

SU

ITE

200

NA

SH

VIL

LE, T

N 3

7204

Pho

ne: (

615)

269

-924

8 Fa

x: (6

15) 6

27-1

298

emai

l: qu

irkde

sign

s@co

mca

st.n

etQ

UIR

K D

ES

IGN

S

PHONE:W335-0732H298-1508

REVISION

PROJECT NO:

COPYRIGHT 2007QUIRK DESIGNS

SHEET 4

A3

/CA

DD

FIL

ES

/Wor

k 20

15/m

itche

ll 11

7 bo

wlin

g 15

-035

/117

c.p

ln

Bon

nie

Mitc

hell

119

Bow

ling

Ave

Nas

hvill

e, ,

TN 3

7205

ROOF PLAN

Add

ition

to R

esid

ence

15-035

DATE: 5/5/15

2 A72 A7

#Drg

ID#L

ayID

#Drg

ID#L

ayID

#Drg

ID#L

ayID

#Drg

ID#L

ayID

1 A7

1 A7

#Drg

ID#L

ayID

#Drg

ID#L

ayID

3 A7

3 A7

4 A7

4 A7

EX

ISTI

NG

RO

OFS

TO

RE

MA

IN

EXIS

TIN

G H

OU

SE

NEW

AD

DIT

ION

3/12

6.5/

126.

5/12

1/12

mem

bran

ero

ofing

1/12

mem

bran

ero

ofing

6.75

/12

6.75

/12

6.75

/12

SC

ALE

: 1"

= 1

0'1

RO

OF

PLA

N

Page 15: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

2931

BE

RR

Y H

ILL

DR

IVE

SU

ITE

200

NA

SH

VIL

LE, T

N 3

7204

Pho

ne: (

615)

269

-924

8 Fa

x: (6

15) 6

27-1

298

emai

l: qu

irkde

sign

s@co

mca

st.n

etQ

UIR

K D

ES

IGN

S

PHONE:W335-0732H298-1508

REVISION

PROJECT NO:

COPYRIGHT 2007QUIRK DESIGNS

SHEET 5

A4

/CA

DD

FIL

ES

/Wor

k 20

15/m

itche

ll 11

7 bo

wlin

g 15

-035

/117

c.p

ln

Bon

nie

Mitc

hell

119

Bow

ling

Ave

Nas

hvill

e, ,

TN 3

7205

BASEMENT PLAN

Add

ition

to R

esid

ence

15-035

DATE: 5/5/15

D363' by8'

D38

18' b

y8'

D38

9' b

y8'

D373' by7'

D38

3' b

y7'

D363' by7'

D37

3' b

y7'

2'-0

"29

'-10

1/2"

2'-0

"

58'-2"3'-11 1/2"16'-7 1/2"3'-0"

49'-5 1/2"8'-9"

33'-2

1/2

"8"

57'-1"1'-1 1/2"20'-7"

33'-1

0 1/

2"

33'-1

0 1/

2"

33'-2

1/2

"8"

58'-2"

2'-0

"

19'-2

"3

1/2"

5'-9

"3

1/2"

8'-4

1/2

"

5'-2"

2 A72 A7

#Drg

ID#L

ayID

#Drg

ID#L

ayID

dem

o fir

epla

ce fo

unda

tion

up

stor

age/

mec

h

wh

hvac

1st

flr

slop

e flr

1.5

"

4" c

onc

slab

w/W

WM

rei

nfov

er 6

mil

vapo

r ba

rrie

r &

4" s

tone

bas

e

4" c

onc

slab

w/W

WM

rei

nfov

er 6

mil

vapo

r ba

rrie

r &

4" s

tone

bas

e

3 C

AR

GA

RA

GE

stor

age/

mec

h#D

rgID

#Lay

ID#D

rgID

#Lay

ID

1 A7

1 A7

#Drg

ID#L

ayID

#Drg

ID#L

ayID

3 A7

4 A7

4 A7

SC

ALE

: 1"

= 1

0'1

BS

MT/

FDN

PLA

N

Page 16: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

2931

BE

RR

Y H

ILL

DR

IVE

SU

ITE

200

NA

SH

VIL

LE, T

N 3

7204

Pho

ne: (

615)

269

-924

8 Fa

x: (6

15) 6

27-1

298

emai

l: qu

irkde

sign

s@co

mca

st.n

etQ

UIR

K D

ES

IGN

S

PHONE:W335-0732H298-1508

REVISION

PROJECT NO:

COPYRIGHT 2007QUIRK DESIGNS

SHEET 6

A5

/CA

DD

FIL

ES

/Wor

k 20

15/m

itche

ll 11

7 bo

wlin

g 15

-035

/117

c.p

ln

Bon

nie

Mitc

hell

119

Bow

ling

Ave

Nas

hvill

e, ,

TN 3

7205

ELEVATIONS

Add

ition

to R

esid

ence

15-035

DATE: 5/5/15

10'-0

"

9'-4

"23

'-2 1

/2"

csmt csmt

SCALE: 1" = 10'1 FRONT ELEVATION

SCALE: 1" = 10'2 REAR ELEVATION

SEE A6 FOR MATERIALS NOTES

NOTE TO CONTRACTOR & OWNER:THIS PROJECT WILL BE INSPECTED BYMETRO HISTORICAL (MHC).CHANGES THAT AFFECT THE ELEVATIONSOR SECTIONS IN ANY WAY SHALL NOT BE MADE,UNLESS APPROVED BY ARCHITECT AND MHC.

Page 17: STAFF RECOMMENDATION - Nashville · 119 Bowling Avenue Metro Historic Zoning Commission, May 20, 2015 1 STAFF RECOMMENDATION 119 Bowling Avenue May 20, 2015 Application: New construction

2931

BE

RR

Y H

ILL

DR

IVE

SU

ITE

200

NA

SH

VIL

LE, T

N 3

7204

Pho

ne: (

615)

269

-924

8 Fa

x: (6

15) 6

27-1

298

emai

l: qu

irkde

sign

s@co

mca

st.n

etQ

UIR

K D

ES

IGN

S

PHONE:W335-0732H298-1508

REVISION

PROJECT NO:

COPYRIGHT 2007QUIRK DESIGNS

SHEET 7

A6

/CA

DD

FIL

ES

/Wor

k 20

15/m

itche

ll 11

7 bo

wlin

g 15

-035

/117

c.p

ln

Bon

nie

Mitc

hell

119

Bow

ling

Ave

Nas

hvill

e, ,

TN 3

7205

SIDE ELEVATIONS

Add

ition

to R

esid

ence

15-035

DATE: 5/5/15

24'-0

1/2

"

SCREENED OPNGS

8" SQ WD COLS

5/4X4" CORNERBOARDS

NEW ADDITION

EXISTING

csmt csmt

DIMENSIONAL FIBERGLASS SHINGLESHARDIPLANK SIDING, SMOOTH FACE, 5" EXPOSUREWOOD OR COMPOSITE WDWS, 4" FLAT CASINGSPLIT FACE BLOCK FOUNDATIONTHIN BRICK VENEER CHIMNEYEXISTING SIDING TO BE REPLACED WITH NEW SMOOTHFACE HARDIPLANK, 3" EXPOSURE TO MATCH EXISTING

11'-4

"

6'-1

1"1'

-6"

7'-1

1"4'

-11"

4'-7

"1'

-0"

2'-9

"

7'-1

1"

1X10 TRIM W/DRIP CAP

bottom of rafter tails

NEW ADDITIONEXISTING

SCALE: 1" = 10'1 LEFT ELEVATION

SCALE: 1" = 10'2 RIGHT ELEVATION

NOTE TO CONTRACTOR & OWNER:THIS PROJECT WILL BE INSPECTED BYMETRO HISTORICAL (MHC).CHANGES THAT AFFECT THEELEVATIONS OR SECTIONS IN ANYWAY SHALL NOT BE MADE, UNLESSAPPROVED BY ARCHITECT AND MHC.