SALT LAKE CITY CORPORATION 451 SOUTH STATE STREET, ROOM 406 WWW.SLCGOV.COM PO BOX 145480 SALT LAKE CITY, UT 84114-5480 TEL 801-535-7757 FAX 801-535-6174 PLANNING DIVISION DEPARTMENT of COMMUNITY and NEIGHBORHOODS Staff Report To: Salt Lake City Planning Commission From: David J. Gellner, AICP, Principal Planner - 801-535-6107 - [email protected] Date: August 8, 2018 Re: PLNPCM2018-00372 Conditional Use – Samoan Independent 7 th Day Adventist Church CONDITIONAL USE PROPERTY ADDRESS: 1624 South 1000 West MASTER PLAN: The Westside Master Plan (2014) ZONING DISTRICT: RMF-35 – Residential Multi-Family REQUEST: Aaron Arbuckle, of Architectural Nexus, representing the Samoan Independent 7 th Day Adventist Church is requesting Conditional Use approval for a new church building to be located at 1624 South 1000 West. The site currently contains an existing church building which will be demolished in order to accommodate the new building. RECOMMENDATION: Based on the information in this staff report, planning staff recommends that the Planning Commission approve the proposed conditional use project subject to complying with all applicable regulations and the conditions of approval listed below. 1. Any modifications to the approved plans after the issuance of a building permit must be specifically requested by the applicant and approved by the Planning Division prior to execution. 2. Applicant shall comply with all other department/division requirements. ATTACHMENTS: A. Vicinity Map & Aerial B. Property Photos C. Site Plan & Elevations D. Additional Applicant Information E. Existing Conditions & Zoning Requirements F. Analysis of Standards G. Public Process and Comments H. Department Comments

Upload: others

Post on 09-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

SALT LAKE CITY CORPORATION

451 SOUTH STATE STREET, ROOM 406 WWW.SLCGOV.COM PO BOX 145480 SALT LAKE CITY, UT 84114-5480 TEL 801-535-7757 FAX 801-535-6174

PLANNING DIVISION DEPARTMENT of COMMUNITY and NEIGHBORHOODS

Staff Report

To: Salt Lake City Planning Commission From: David J. Gellner, AICP, Principal Planner - 801-535-6107 - [email protected] Date: August 8, 2018

Re: PLNPCM2018-00372 – Conditional Use – Samoan Independent 7th Day Adventist Church

CONDITIONAL USE PROPERTY ADDRESS: 1624 South 1000 West

MASTER PLAN: The Westside Master Plan (2014)

ZONING DISTRICT: RMF-35 – Residential Multi-Family

REQUEST: Aaron Arbuckle, of Architectural Nexus, representing the Samoan Independent 7th Day Adventist Church is requesting Conditional Use approval for a new church building to be located at 1624 South 1000 West. The site currently contains an existing church building which will be demolished in order to accommodate the new building. RECOMMENDATION: Based on the information in this staff report, planning staff recommends that the Planning Commission approve the proposed conditional use project subject to complying with all applicable regulations and the conditions of approval listed below.

1. Any modifications to the approved plans after the issuance of a building permit must be specifically requested by the applicant and approved by the Planning Division prior to execution.

2. Applicant shall comply with all other department/division requirements. ATTACHMENTS:

A. Vicinity Map & Aerial B. Property Photos C. Site Plan & Elevations D. Additional Applicant Information E. Existing Conditions & Zoning Requirements F. Analysis of Standards G. Public Process and Comments H. Department Comments

Page 2: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 2

PROJECT DESCRIPTION: This request is for a new church building to be located at 1624 South 1000 West for the Samoan Independent 7th Day Adventist Church. The site currently contains an existing church building which will be demolished in order to accommodate the new building. A more detailed description of the project details is included in the narrative submitted by the applicant included in Attachment D of this report. The new 2-story church building will include a sanctuary space, a multi-function/gym space, auxiliary conference room, office and support spaces, and, a 2-bedroom residential unit for occasional occupancy by visiting clergy. Staffing is expected to be approximately 3-4 employees in the building at any one time. The sanctuary will hold approximately 250-206 people while the multi-function space will hold approximately 150-160 people. Both spaces will not be used concurrently. KEY CONSIDERATIONS: The key considerations listed below have been identified through the analysis of the project, neighbor and community input and department review comments. Consideration 1: Residential Unit for Visiting Clergy The proposed new church includes a residential unit for occasional occupancy by visiting clergy. The initial zoning reviewer comments indicated a concern that this aspect of the proposal would appear to be along the lines of a hotel/motel, or a dwelling unit for accessory guest & servants quarters, neither of which are permitted in the RMF-35 zoning district. The City, through a past administrative interpretation has determined that a residential unit for clergy is allowed as an accessory use to the main use of the property for a place of worship because this type of residential use is commonly found in many churches. The proposed residential unit is allowed and parking calculations have taken this use into account. Consideration 2: Lot Consolidation The subject property consists of two adjacent parcels. One parcel contains the existing church at this site while the other parcel is currently dedicated to surface parking. The proposal retains this basic configuration with the church building located on one parcel and the other parcel dedicated to surface parking. Since off-site parking is not a permitted use in this RMF-35 zoning district, consolidation of the two (2) parcels is required. This is an administrative application that can be approved by staff and does not require Planning Commission approval. Consideration 3: Neighborhood Compatibility and Impact The existing use of the property is for a place of worship (church) which is being replaced by an upgraded building that would better meet the needs of the congregation and the desired programming in that space. The use of the property and anticipated impact from that use would not be significantly changing from that which currently exists on the site. DISCUSSION: The proposed use is essentially replacing an established use on the property with the same but in an upgraded facility. The new facility is expected to continue to work compatibly within the context of its location.

NEXT STEPS: If the conditional use is approved, the applicant will be required to comply with all other department/division requirements and obtain all necessary building permits for the project.

Page 3: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 3

ATTACHMENT A: VICINITY MAP & AERIAL

Page 4: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 4

ATTACHMENT B: PROPERTY PHOTOS

GD9464
Rectangle
Page 5: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 5

ATTACHMENT C: SITE PLAN & ELEVATIONS

GD9464
Rectangle
Page 6: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

Nexus Project #: Owner Project #:

SAMOAN INDEPENDENTSEVENTH-DAYADVENTIST CHURCH

SISDAC UTAH

1624 S 1000 WSALT LAKE CITY, UT 84104

DESIGN DEVELOPMENT

05/17/18

18030

[STAMP]

CONTACT: E-MAIL:

PHONE: INTERNET:

[LOGO]

OWNER

Samoan Independent Seventh-Day Adventist Church1624 S 1000 W

Salt Lake City, UT 84104

385.775.0313

Marilyn Spizzirri-Patu [email protected]

CONTACT: E-MAIL:

PHONE: INTERNET:

ARCHITECT

Architectural NEXUS, Inc.2505 East Parleys Way

Salt Lake City, UT 84109

801.924.5000

Aaron Arbuckle [email protected]

http://www.archnexus.com

CONTACT: E-MAIL:

PHONE: INTERNET:

LANDSCAPE ARCHITECT

Architectural NEXUS, Inc.2505 East Parleys Way

Salt Lake City, UT 84109

801.924.5000

Adam Castor [email protected]

http://www.archnexus.com

[STAMP]

CONTACT: E-MAIL:

PHONE: INTERNET:

[LOGO]

STRUCTURAL

ARW Engineers1594 Park Circle

Ogden, Utah 84404

801.782.6008

Josh Blazzard [email protected]

[STAMP]

CONTACT: E-MAIL:

PHONE: INTERNET:

[LOGO]

MECHANICAL

VBFA330 South 300 East

Salt Lake City, UT 84111

801.530.3148

Ben Davis [email protected]

[STAMP]

CONTACT: E-MAIL:

PHONE: INTERNET:

[LOGO]

ELECTRICAL

EELD1220 S 300 W

Salt Lake City, UT 84101

801.486.2222

Mansour Aghdasi [email protected]

DATE:DRAWN BY:CHECKED BY:NEXUS PROJECT #:

Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, UT 84109T 801.924.5000 http://www.archnexus.com

Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.© Architectural Nexus, Inc. 2017

54321

D

C

B

A

5/1

7/2

018

10:5

1:0

3 A

M

COVERSHEET

RS

1624 S

1000 W

SA

LT L

AK

E C

ITY

, U

T 8

4104

SA

MO

AN

IN

DE

PE

ND

EN

T S

EV

EN

TH

-DA

YA

DV

EN

TIS

T C

HU

RC

H

18030

05/17/18

SIS

DA

C U

TA

H

DESIGNDEVELOPMENT

G001

AA

APPROVALS

Signer 1 Date

Signer 2 Date

Signer 3 Date

Signer 4 Date

# Date Revision

[STAMP]

CONTACT: E-MAIL:

PHONE: INTERNET:

[LOGO]

CIVIL

CRS4246 S Riverboat Rd, Ste 200

Salt Lake City, UT 84123

801.359.5565

Greg Nelson [email protected]

Page 7: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

SS

SS

SSSS

SSSS

SSSS

SSSS

GG

GG

GG

GG

GG

GG

GG

GG

GG

GGG

OO

OO

OO

OO

OOOOOOOOOOOOOOOOOOO

OO

OO

OO

OO

OO

OO

OO

OO

O

OO

O O O O O O O O O O O O O O O

OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OEOE

OEOE

PP

PP

OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OEOE

OEOE

OE

OEOE

OEOE

OEOE

OEOE

OEOE

OEOE

OEOE

OEOE

OEOE

OEOE

OEOE

OE

PPOE

PPPP OE

OE

OE

PP

BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTVBCTV

BCTVBCTV

BCTVBCTV

BCTVBCTV

BCTVBCTV

BCTVBCTV

BCTVBCTV

BCTVBCTV

BCTVBCTV

OO

O

OOO

O

OOOO

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SSSS

SSSS

SSSS

SSSS

SSSS

SSSS

SS

WW

WW

WW

WW

WW

WW

WW

WW

WW

WW

WW

WW

W W W W

W W W

SD

SD

SD

SD

SD

SD

SD

SD

SD

PP

CO COSS SS SS SS SS SS SS SS

SITE PLAN GENERAL

NOTES:

Site Plan Legend

·····

···

···

···

···

SITE TABULATIONS:

···

··

PARKING DATA:

16

24

S

ou

th

1

00

0 W

es

t

Sa

lt L

ak

e C

ity

, U

T 8

41

02

SA

MO

AN

IN

DE

PE

ND

EN

T S

EV

EN

TH

-D

AY

SIS

DA

C U

TA

H

DATE: 05.18.18

DRAWN BY:

CHECKED BY:

NEXUS PROJECT #: 18030

# Date Revision

Original drawings remain the property

of the Architect and as such the

Architect retains total ownership and

control. The design represented by

these drawings is sold to the client for

a one time use, unless otherwise

agreed upon in writing by the

Architect.

© Architectural Nexus, Inc. 2017

Architectural NEXUS, Inc.

2505 East Parleys Way

Salt Lake City, UT 84109

T 801.924.5000

http://www.archnexus.com

54321

D

C

B

A

AD

VE

NT

IS

T C

HU

RC

H

CONDITIONAL

USE PERMIT

N

SITE

IMPROVEMENTS

PLAN

AS101

KEY MAP

SITE

S 1

00

0 W

RMF-35

CB

R-1

-7

00

0

1:100 N

AC

HT

AutoCAD SHX Text
Description
AutoCAD SHX Text
A. TAX PARCEL #151425201300000. LEGAL TAX PARCEL #151425201300000. LEGAL DESCRIPTION: BEG E 12 RDS & N 455.395 FT FR SW COR OF NE 1/4 SEC 14, T 1S, R 1W, SLM; N 0^11'15" E 50 FT; S 89^55'53" W 192.78 FT; S 0^11'15" W 50 FT; N 89^55'53" E 192.78 FT TO BEG. 0.22 AC 7100-749 9321-542 9875-6308 B. TAX PARCEL #15142520140000. LEGAL TAX PARCEL #15142520140000. LEGAL DESCRIPTION: BEG E 198 FT & N 317.695 FT FR CEN SEC 14, T 1S, R 1W, S L MN 0^11'15" E 137.7 FT; S 89^55'53" W 192.78 FT; S 0^11'15" W137.7 FT M OR L; N 89^55'53" E 192.78 FT TO BEG. 0.61 AC M OR L 4914-0787 6469-1281 6592-1987 7100-0751 7452-2348 8595-6349 9875-6308 C. SEE CIVIL, LANDSCAPE, ARCHITECTURAL, SEE CIVIL, LANDSCAPE, ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. D. OFF-STREET PARKING IS TO COMPLY WITH OFF-STREET PARKING IS TO COMPLY WITH SALT LAKE CITY ORDINANCE (21A.44.020) AND RELATED SECTIONS. E. LANDSCAPE REQUIREMENTS INCLUDING, BUT LANDSCAPE REQUIREMENTS INCLUDING, BUT NOT LIMITED TO, LANDSCAPE BUFFERS ARE TO COMPLY WITH SALT LAKE CITY ORDINANCE (21A.48) AND RELATED SECTIONS.
AutoCAD SHX Text
Symbol
AutoCAD SHX Text
PAVING CONTROL JOINT (SAW CUT)
AutoCAD SHX Text
PAVING EXPANSION JOINT
AutoCAD SHX Text
PROPOSED CONCRETE PAVING (1,781 SF)
AutoCAD SHX Text
EXISTING ASPHALT (13,088 SF)
AutoCAD SHX Text
EXISTING TURF (1,174 SF)
AutoCAD SHX Text
PROPOSED TURF (7,345 SF)
AutoCAD SHX Text
PROPOSED UTILITY COMPATIBLE TREE (6 QTY.)
AutoCAD SHX Text
PROPOSED SHADE TREE (19 QTY.)
AutoCAD SHX Text
PROPOSED PRIVACY FENCE
AutoCAD SHX Text
PROPOSED SHRUB (112 QTY.)
AutoCAD SHX Text
EXISTING CONTOUR
AutoCAD SHX Text
TOTAL SITE AREA: 0.82 AC (100.0%) 0.82 AC (100.0%) BUILDING AREA: 0.22 AC (27%) 0.22 AC (27%) OFFSTREET PARKING AREA: 0.31 AC (38%) 0.31 AC (38%) *IRRIGATED TURF AREA: 0.25 AC (30%) 0.25 AC (30%) HARDSCAPE PAVING AREA: 0.04 AC (5%) 0.04 AC (5%) FRONT YARD: 1000 WEST 187.0 LF 187.0 LF TREES REQUIRED (1/50 FT): 3.7 3.7 TREES PROVIDED: 5.0 5.0 INTERIOR YARD NORTH: 192.0 LF 192.0 LF TREES REQUIRED (1/30 FT): 6.4 6.4 TREES PROVIDED: 6.0 6.0 INTERIOR YARD SOUTH: 192.0 LF 192.0 LF TREES REQUIRED (1/30 FT): 6.4 6.4 TREES PROVIDED: 6.0 6.0 REAR YARD: 187.0 LF 187.0 LF TREES REQUIRED (1/30 FT): 6.2 6.2 TREES PROVIDED: 6.06.0
AutoCAD SHX Text
*EXCLUDES PROPOSED PUBLIC RIGHT-OF-WAY IMPROVEMENTS
AutoCAD SHX Text
REQUIRED PARKING CALCULATIONS BUILDING FOOTPRINT 9,683 SF 9,683 SF REQUIRED STANDARD STALLS 19 19 REQUIRED ADA STALLS 2 2 TOTAL REQUIRED STALLS 21 21 PROPOSED NEW PARKING NEW STANDARD STALLS 20 20 NEW ADA STALLS 2 2 TOTAL PROVIDED PARKING 2222
AutoCAD SHX Text
40
AutoCAD SHX Text
20
AutoCAD SHX Text
10
AutoCAD SHX Text
5
AutoCAD SHX Text
0
AutoCAD SHX Text
1"=20'
AutoCAD SHX Text
PROPERTY BOUNDARY
AutoCAD SHX Text
PROPERTY SETBACK
AutoCAD SHX Text
PROPERTY BOUNDARY
AutoCAD SHX Text
PROPERTY BOUNDARY
AutoCAD SHX Text
PROPERTY BOUNDARY
AutoCAD SHX Text
SERBIAN ORTHODOX CHURCH
AutoCAD SHX Text
SINGLE FAMILY RESIDENTIAL UNIT
AutoCAD SHX Text
S 1000 W
AutoCAD SHX Text
PROPOSED CHURCH BUILDING F.F.E. 4230.32'4230.32'
AutoCAD SHX Text
PROPOSED PARKING (20 STANDARD STALLS, 2 ADA STALLS)
AutoCAD SHX Text
PRIVACY FENCE (TYP.)
AutoCAD SHX Text
MAIN ENTRANCE
AutoCAD SHX Text
EXISTING CONCRETE SIDEWALK
AutoCAD SHX Text
EXISTING PARKSTRIP
AutoCAD SHX Text
SHADE TREE (TYP.)
AutoCAD SHX Text
VEHICLE ENTRANCE, ONE-WAY
AutoCAD SHX Text
TRASH ENCLOSURE
AutoCAD SHX Text
LANDSCAPE BUFFER (TYP.)
AutoCAD SHX Text
PRIVACY FENCE (TYP.)
AutoCAD SHX Text
SHADE TREE
AutoCAD SHX Text
PROPERTY SETBACK
AutoCAD SHX Text
TAX PARCEL 15142520140000 (SEE NOTES B)
AutoCAD SHX Text
TAX PARCEL 15142520130000 (SEE NOTES A)
AutoCAD SHX Text
FIRE LANE ACCESS
AutoCAD SHX Text
SECURITY GATE (TYP.)
Page 8: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

SS

SS

SSSS

SSSS

400374228.05WV

GG

GG

GG

GG

G

G

OO

O

O

OOOOOOOOOO

OO

OO

OO

O

O O O O O O O O

OE OE OE OE OE OE OE OE OE OE

OE

PP

PP

OE OE OE OE OE OE OE OE OE OEOE

OEOE

OEOE

OEOE

OEOE

OEOE

OE

PP

PPPP

OE

PP

BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTV BCTV

BCTVBCTV

BCTVBCTV

BCTVBCTV

BCTVBCTV

TPTP

O

OO

OO

SD

SD

SD

SD

SD

SD

SD

SSSS

SSSS

SSSS

SSSS

WW

WW

WW

WW

WW

WW

W

W W

W

SD

SD

SD

SD

SD SD SD SD

PP

CO COSS SS SS SS

4227

4228

4227

4226

4228

4228

4227

4228

4228

4228 42

28 4228

4227

WM

WM

WM

WM

WM

(137

.70' R

ecor

d)

(137

.70' R

ecor

d)

S89°49'01"E 192.78'

N0°2

6'22"

E 50

.00'

N0°2

6'22"

E 13

7.51'

N0°2

6'22"

E 13

7.51'

S89°49'01"E 192.78'

N0°2

6'22"

E 50

.00'

S89°49'01"E 192.78'

PARCEL 15142520140000A PART OF THE NORTHWEST QUARTER OF SECTION 14, TOWNSHIP 1 SOUTH, RANGE 1 WEST OF THE SALT LAKE BASE AND MERIDIAN. BEGINNING AT A POINT ON THEWEST RIGHT-OF-WAY LINE OF 1000 WEST STREET LOCATED NORTH 00°25'52" EAST, A DISTANCE OF 214.74 FEET AND SOUTH 89°51'56" WEST, A DISTANCE OF 33.06FEET FROM THE CITY MONUMENT IN THE INTERSECTION OF 1700 SOUTH AND 1000 WEST STREETS, SAID POINT BEING LOCATED BY RECORD EAST 198.00 FEET ANDNORTH 317.695 FEET FROM THE CENTER OF SAID SECTION 14; RUNNING THENCE NORTH 89°49'01" WEST, A DISTANCE OF 192.78 FEET; THENCE NORTH 00°26'22" EAST,A DISTANCE OF 137.51 FEET (137.70' RECORD); THENCE SOUTH 89°49'01" EAST, A DISTANCE OF 192.78 FEET TO THE SAID WEST RIGHT-OF-WAY LINE; THENCE SOUTH00°26'22" WEST, A DISTANCE OF 137.51 FEET (137.70' RECORD) ALONG SAID WEST RIGHT-OF-WAY LINE TO THE POINT OF BEGINNING.CONTAINING 0.6086 ACRES.

PARCEL 15142520130000A PART OF THE NORTHWEST QUARTER OF SECTION 14, TOWNSHIP 1 SOUTH, RANGE 1 WEST OF THE SALT LAKE BASE AND MERIDIAN. BEGINNING AT A POINT ON THEWEST RIGHT-OF-WAY LINE OF 1000 WEST STREET LOCATED NORTH 00°25'52" EAST, A DISTANCE OF 351.92 FEET AND SOUTH 89°51'56" WEST, A DISTANCE OF 33.04FEET FROM THE CITY MONUMENT IN THE INTERSECTION OF 1700 SOUTH AND 1000 WEST STREETS, SAID POINT BEING LOCATED BY RECORD EAST 12 RODS ANDNORTH 455.395 FEET FROM THE CENTER OF SAID SECTION 14; RUNNING THENCE NORTH 89°49'01" WEST, A DISTANCE OF 192.78 FEET; THENCE NORTH 00°26'22"EAST, A DISTANCE OF 50.00 FEET; THENCE SOUTH 89°49'01" EAST, A DISTANCE OF 192.78 FEET TO THE SAID WEST RIGHT-OF-WAY LINE; THENCE SOUTH 00°26'22"WEST, A DISTANCE OF 50.00 FEET ALONG SAID WEST RIGHT-OF-WAY LINE TO THE POINT OF BEGINNING.CONTAINING 0.2213 ACRES.

S89°34'08"E 33.04'

N89°51'56"E 33.06'

S0°2

5'52"

W 6

21.94

'35

1.92'

214.7

4'

SITE AND UTILITY KEYED NOTESRAISE EXISTING CATCH BASIN TO GRADE

PROTECT IN PLACE EXISTING STORM DRAIN PIPE/ CATCH BASIN

PROTECT IN PLACE EX LIGHT POLE

INSTALL 18F SNOUT OR EQUAL ON OUTLET PIPEOLDCASTLE 2' X 3' CATCH BASIN W/ CURB BACK FRAME AND GRATEOR EQUALOLDCASTLE 2' X 2' CATCH BASIN W/ FRAME AND GRATE OR EQUAL

STORM DRAIN PIPE PER DETAIL 1/CU501

RELOCATE EXISTING SIGN PER DETAIL 4/CP502

LIGHT POLE. REFER TO ELECTRICAL PLANS FOR DETAIL.FIELD LOCATE EX WATER LINE AND INSTALL PVC C900 WATERLINE,BENDS, AND APPURTENANCES TO CONNECT NEW FIRE HYDRANTASSEMBLY TO EX WATER LATERAL PER DETAIL 2/CU501 & 4/CU501RAISE POWER LINES BY OTHERS. COORDINATE CONSTRUCTION ANDDESIGN WITH COMCAST CABLECURB WALL PER DETAIL 6/CP501

TRANSITION FROM TYPE "A" TO TYPE "B" CURB & GUTTER

TYPE "A" CURB & GUTTER PER APWA SP 205

TYPE "B" CURB & GUTTER PER DETAIL 1/CP501

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

SITE AND UTILITY KEYED NOTESRAISE EXISTING CATCH BASIN TO GRADE

PROTECT IN PLACE EXISTING STORM DRAIN PIPE/ CATCH BASIN

PROTECT IN PLACE EX LIGHT POLE

INSTALL 18F SNOUT OR EQUAL ON OUTLET PIPEOLDCASTLE 2' X 3' CATCH BASIN W/ CURB BACK FRAME AND GRATEOR EQUALOLDCASTLE 2' X 2' CATCH BASIN W/ FRAME AND GRATE OR EQUAL

STORM DRAIN PIPE PER DETAIL 1/CU501

RELOCATE EXISTING SIGN PER DETAIL 4/CP502

LIGHT POLE. REFER TO ELECTRICAL PLANS FOR DETAIL.FIELD LOCATE EX WATER LINE AND INSTALL PVC C900 WATERLINE,BENDS, AND APPURTENANCES TO CONNECT NEW FIRE HYDRANTASSEMBLY TO EX WATER LATERAL PER DETAIL 2/CU501 & 4/CU501RAISE POWER LINES BY OTHERS. COORDINATE CONSTRUCTION ANDDESIGN WITH COMCAST CABLECURB WALL PER DETAIL 6/CP501

TRANSITION FROM TYPE "A" TO TYPE "B" CURB & GUTTER

TYPE "A" CURB & GUTTER PER APWA SP 205

TYPE "B" CURB & GUTTER PER DETAIL 1/CP501

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

SITE AND UTILITY KEYED NOTESRAISE EXISTING CATCH BASIN TO GRADE

PROTECT IN PLACE EXISTING STORM DRAIN PIPE/ CATCH BASIN

PROTECT IN PLACE EX LIGHT POLE

INSTALL 18F SNOUT OR EQUAL ON OUTLET PIPEOLDCASTLE 2' X 3' CATCH BASIN W/ CURB BACK FRAME AND GRATEOR EQUALOLDCASTLE 2' X 2' CATCH BASIN W/ FRAME AND GRATE OR EQUAL

STORM DRAIN PIPE PER DETAIL 1/CU501

RELOCATE EXISTING SIGN PER DETAIL 4/CP502

LIGHT POLE. REFER TO ELECTRICAL PLANS FOR DETAIL.FIELD LOCATE EX WATER LINE AND INSTALL PVC C900 WATERLINE,BENDS, AND APPURTENANCES TO CONNECT NEW FIRE HYDRANTASSEMBLY TO EX WATER LATERAL PER DETAIL 2/CU501 & 4/CU501RAISE POWER LINES BY OTHERS. COORDINATE CONSTRUCTION ANDDESIGN WITH COMCAST CABLECURB WALL PER DETAIL 6/CP501

TRANSITION FROM TYPE "A" TO TYPE "B" CURB & GUTTER

TYPE "A" CURB & GUTTER PER APWA SP 205

TYPE "B" CURB & GUTTER PER DETAIL 1/CP501

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

SANITARY SEWERSTORM DRAINXXXXXXXXXXXXMAJOR CONTOURMINOR CONTOUR

SS

SD

42004201

LEGENDSANITARY SEWERSTORM DRAINXXXXXXXXXXXXMAJOR CONTOURMINOR CONTOUR

SS

SD

42004201

LEGENDSANITARY SEWERSTORM DRAINXXXXXXXXXXXXMAJOR CONTOURMINOR CONTOUR

SS

SD

42004201

LEGEND

EX SANITARY SEWER MANHOLE

EX STORM DRAIN MANHOLE

EX ELECTRICAL MANHOLEE

SS

SD

EX SANITARY SEWER MANHOLE

EX STORM DRAIN MANHOLE

EX ELECTRICAL MANHOLEE

SS

SD

EX SANITARY SEWER MANHOLE

EX STORM DRAIN MANHOLE

EX ELECTRICAL MANHOLEE

SS

SD

GENERAL NOTES1. THE ENGINEER HAS MADE AN EXTENSIVE EFFORT TO LOCATE ALL

EXISTING UTILITY LINES FROM RECORDS PROVIDED BY OTHERS ANDEVIDENCE IN THE FIELD. CONTRACTOR TO VERIFY ALL EXISTINGUTILITY LOCATIONS PRIOR TO COMMENCING WORK.

2. SANITARY SEWER CONSTRUCTION SHALL COMPLY WITH CENTRALDAVIS SEWER DISTRICT DESIGN STANDARDS & SPECIFICATIONS.

3. ROADWAY CONSTRUCTION SHALL COMPLY WITH FARMINGTON CITYDESIGN STANDARDS AND SPECIFICATIONS.

4. ADD 4200 TO FINISH GRADE ELEVATIONS SHOWN TO OBTAIN ACTUALFINISH GRADE ELEVATION.

GENERAL NOTES1. THE ENGINEER HAS MADE AN EXTENSIVE EFFORT TO LOCATE ALL

EXISTING UTILITY LINES FROM RECORDS PROVIDED BY OTHERS ANDEVIDENCE IN THE FIELD. CONTRACTOR TO VERIFY ALL EXISTINGUTILITY LOCATIONS PRIOR TO COMMENCING WORK.

2. SANITARY SEWER CONSTRUCTION SHALL COMPLY WITH CENTRALDAVIS SEWER DISTRICT DESIGN STANDARDS & SPECIFICATIONS.

3. ROADWAY CONSTRUCTION SHALL COMPLY WITH FARMINGTON CITYDESIGN STANDARDS AND SPECIFICATIONS.

4. ADD 4200 TO FINISH GRADE ELEVATIONS SHOWN TO OBTAIN ACTUALFINISH GRADE ELEVATION.

GENERAL NOTES1. THE ENGINEER HAS MADE AN EXTENSIVE EFFORT TO LOCATE ALL

EXISTING UTILITY LINES FROM RECORDS PROVIDED BY OTHERS ANDEVIDENCE IN THE FIELD. CONTRACTOR TO VERIFY ALL EXISTINGUTILITY LOCATIONS PRIOR TO COMMENCING WORK.

2. SANITARY SEWER CONSTRUCTION SHALL COMPLY WITH CENTRALDAVIS SEWER DISTRICT DESIGN STANDARDS & SPECIFICATIONS.

3. ROADWAY CONSTRUCTION SHALL COMPLY WITH FARMINGTON CITYDESIGN STANDARDS AND SPECIFICATIONS.

4. ADD 4200 TO FINISH GRADE ELEVATIONS SHOWN TO OBTAIN ACTUALFINISH GRADE ELEVATION.Fil

e Path

:P:\1

8065

c arch

nexu

s-sam

oan c

hurch

\Dra

wing

s\SHE

ETS\

CS10

1-EX

ISTI

NG C

ONDI

TION

S.dw

g

Ma

y 16,

2018

- 10

:45am

N

0 20' 40'

SHEET NUMBER

SHEET OF

PROJECT NUMBER

THE INFORMATION CONTAINED IN THIS DRAWING ISTHE PROPERTY OF CRS ENGINEERS AND IS NOT TOBE REPRODUCED, MODIFIED OR USED FOR ANY OTHERPROJECT OR EXTENSION OF THIS PROJECT EXCEPT BYAGREEMENT WITH CRS ENGINEERS.

RECORD OF REVISIONS STAMP0 1

IF THE ABOVE SCALE BAR DOES NOT MEASURE 1-INCHIN LENGTH, DO NOT USE THIS DRAWING FOR SCALINGPURPOSES. DIMENSIONS AND MEASUREMENTSSPECIFIED IN THE DRAWING TAKE PRECEDENCE TOSCALED MEASUREMENTS.

PROJECT MANAGER

PRINCIPAL

CHECKED BY

DRAWN BY

DRAWING SCALE

ISSUE DATE

2

4246 S Riverboat Rd, Ste 200 | Salt Lake City, UT 84123 | P: 801.359.5565 | www.crsengineers.com

SISDAC UTAHARCH NEXUS-SAMOAN CHURCH

18065C

1624 S 1000 W SALT LAKE CITY, UTAHCS101

3 10

DEC 25, 2016

M. HIRST, PE

G. NELSON, PE

D. CROMAR, PE

K. FOSTER

EXISTING CONDITIONS

1" = 20'

30%

AutoCAD SHX Text
P.O.B.
AutoCAD SHX Text
P.O.B.
Page 9: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

OO

O

O

OOOOOOOOO

OO

OO

OO

OO

O O O O O O O O

O

OO

OO

WW

WW

WW

WW

WW

WW

W W

W

O O O O O

UP

UP

UP

UP

IRRIGATION

CONSTRUCTION NOTES:

IRRIGATION GENERAL

NOTES:

EMITTER SCHEDULE:

O

OO

UPUP

2222

2222

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

OO

UP

UP

UP

UP

2

1

2222

22222

1111

11111

2

1

2222

22222

1111

11111

2

1

2222

22222

111

1111

11111

11111

22222

22222

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

1624 S

ou

th

1000 W

est

Salt L

ake C

ity, U

T 84102

SA

MO

AN

IN

DE

PE

ND

EN

T S

EV

EN

TH

-D

AY

SIS

DA

C U

TA

H

DATE:

DRAWN BY:

CHECKED BY:

NEXUS PROJECT #:

# Date Revision

Original drawings remain the property

of the Architect and as such the

Architect retains total ownership and

control. The design represented by

these drawings is sold to the client for

a one time use, unless otherwise

agreed upon in writing by the

Architect.

© Architectural Nexus, Inc. 2017

Architectural NEXUS, Inc.

2505 East Parleys Way

Salt Lake City, UT 84109

T 801.924.5000

http://www.archnexus.com

54321

D

C

B

A

AD

VE

NT

IS

T C

HU

RC

H

DESIGN

DEVELOPMENT

N

AC

HT

IRRIGATION

PLAN

LI101

A1

LP101

IRRIGAITON PLAN - ADD ALTERNATE

SCALE: 1" = 20'

LI101A1

C1

LP101

IRRIGAITON PLAN - ADD ALTERNATE

SCALE: 1" = 20'

LI101C1

A3

LI101

IRRIGATION PLAN

SCALE: 1" = 20'

A

C

B

D

E

AutoCAD SHX Text
POC
AutoCAD SHX Text
A
AutoCAD SHX Text
WHERE MORE THAN ONE EMITTER IS REQUIRED FOR PLANT, SPACE EMITTERS EQUIDISTANT AROUND ROOTBALL
AutoCAD SHX Text
PLANT SIZE 1 GAL 3 GAL 5 GAL 2" TREE RING
AutoCAD SHX Text
EMITTER GPH .5 2 5 -
AutoCAD SHX Text
QTY. PER PLANT 1 1 1 1
AutoCAD SHX Text
A. AT THE POINT OF CONNECTION INSTALL (1) AT THE POINT OF CONNECTION INSTALL (1) CURB VALVE (STOP AND WASTE) VALUE AND (1) BACKFLOW PREVENTION DEVICE B. COORDINATE LOCATION AND INSTALLATION COORDINATE LOCATION AND INSTALLATION OF ALL SLEEVES AND CONDUITS AS SHOWN ON THE IRRIGATION PLAN PRIOR TO INSTALLATION OF ASPHALT AND CONCRETE PAVING (SEE TRENCH DETAILS). C. INSTALL MANUAL DRAIN VALVES AT THE LOW INSTALL MANUAL DRAIN VALVES AT THE LOW POINT OF MAIN LINE LOOP AND AT THE END OF MAIN LINE BRANCHES (SEE LEGEND). D. INSTALL AIR/VACUUM RELIEF VALVE AT LOW INSTALL AIR/VACUUM RELIEF VALVE AT LOW POINT OF MAIN LINE LOOP AND AT THE ENDS OF MAIN LINE BRANCHES (SEE LEGEND). E. INSTALL CONTROLLER GROUNDING ROD.INSTALL CONTROLLER GROUNDING ROD.
AutoCAD SHX Text
1. VERIFYING THE STATIC WATER PRESSURE AT VERIFYING THE STATIC WATER PRESSURE AT THE POINT OF CONNECTION PRIOR TO BEGINNING WORK AND INFORMING THE LANDSCAPE ARCHITECT OF ANY DISCREPANCIES BETWEEN THE STATED STATIC WATER PRESSURE AND ACTUAL STATIC WATER PRESSURE READINGS AT THE POINT OF CONNECTION. WATER PRESSURE DISCREPANCIES SHALL BE NOTED ON CONTRACTOR COMPANY LETTERHEAD AND SUBMITTED TO THE LANDSCAPE ARCHITECT PRIOR TO BEGINNING WORK. IN THE EVENT THE CONTRACTOR FAILS TO VERIFY AND CONFIRM STATED VERSUS ACTUAL STATIC WATER PRESSURE PRIOR TO BEGINNING WORK AND DISCREPANCIES DO IN FACT EXIST, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL MODIFICATIONS TO THE IRRIGATION SYSTEM AT NO ADDITIONAL COST TO THE OWNER. 2. THE CONTRACTOR IS RESPONSIBLE FOR THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE LOCATION OF THE ELECTRICAL ROOM INSIDE THE BUILDING AND PROVIDING POWER TO THE CONTROLLER LOCATION. SHOULD THE CONTRACTOR FAIL TO PROVIDE POWER TO THE CONTROLLER, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL MODIFICATIONS NECESSARY TO PROVIDED POWER TO THE CONTROLLER AT NO ADDITIONAL COST TO THE OWNER. 3. POINT OF CONNECTION COMPONENTS SHALL POINT OF CONNECTION COMPONENTS SHALL BE CONNECTED TO THE AUTOMATIC CONTROLLER IN SEPARATE CONDUITS AND AS INSTRUCTED BY THE MANUFACTURER. 4. IRRIGATION CONTROL VALVES SHALL BE IRRIGATION CONTROL VALVES SHALL BE CONNECTED TO THE AUTOMATIC CONTROLLER WITH DIRECT BURIAL, CONVENTIONAL WIRING. 5. ALL TURFGRASS AREAS SHALL BE IRRIGATED ALL TURFGRASS AREAS SHALL BE IRRIGATED WITH POP-UP SPRAY HEADS, WHICH SHALL PROVIDE 100% HEAD TO HEAD COVERAGE. 6. ALL PLANTER AREAS SHALL BE IRRIGATED ALL PLANTER AREAS SHALL BE IRRIGATED WITH POINT SOURCE DRIP IRRIGATION. 7. IRRIGATION ZONES ARE IDENTIFIED WITH THE IRRIGATION ZONES ARE IDENTIFIED WITH THE FOLLOWING SYMBOL:
AutoCAD SHX Text
VALVE TYPE
AutoCAD SHX Text
A-XX
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
DRIP
AutoCAD SHX Text
GPM
AutoCAD SHX Text
STATION NUMBER
AutoCAD SHX Text
VALVE SIZE
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
POC
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
POC
AutoCAD SHX Text
40
AutoCAD SHX Text
20
AutoCAD SHX Text
10
AutoCAD SHX Text
5
AutoCAD SHX Text
0
AutoCAD SHX Text
1"=20'
AutoCAD SHX Text
A-1
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
TRF
AutoCAD SHX Text
A-2
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
SHB
AutoCAD SHX Text
A-3
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
TRF
AutoCAD SHX Text
A-5
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
TRF
AutoCAD SHX Text
A-4
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
SHB
AutoCAD SHX Text
A-7
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
TRF
AutoCAD SHX Text
A-6
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
SHB
AutoCAD SHX Text
A-8
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
TRF
AutoCAD SHX Text
A-9
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
SHB
AutoCAD SHX Text
A-10
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
TRF
AutoCAD SHX Text
LIMITS OF CONSTRUCTION
AutoCAD SHX Text
LIMITS OF CONSTRUCTION
AutoCAD SHX Text
SERBIAN ORTHODOX CHURCH
AutoCAD SHX Text
SINGLE FAMILY RESIDENTIAL UNIT
AutoCAD SHX Text
PROPOSED CHURCH BUILDING
AutoCAD SHX Text
A-1
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
TRF
AutoCAD SHX Text
A-1.A
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
SHR
AutoCAD SHX Text
A-8
AutoCAD SHX Text
1"
AutoCAD SHX Text
XX
AutoCAD SHX Text
SHR
Page 10: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

DN

UP

UP

UP

UP

DN

A. PLAN WALL DIMENSIONS ARE TO GRID LINE OR FACE OF WALL STRUCTURE. "CLEAR" DIMENSIONS ARE TO FACE OF WALL FINISH.

B. FIELD VERIFY ALL EXISTING CONDITIONS AND THEIR COMPATIBILITY WITH NEW CONSTRUCTION PRIOR TO THE COMMENCEMENT OF WORK. COORDINATE DISCREPANCIES WITH ARCHITECT.

C. DO NOT SCALE DRAWINGS.D. SEE CIVIL, STRUCTURAL, MECHANICAL AND

ELECTRICAL DRAWINGS FOR MORE INFORMATION.E. SEE G SERIES SHEETS FOR WALL TYPES AND

TYPICAL ACCESSIBILITY CLEARANCE AND COMPLIANCE REQUIREMENTS.

F. PROVIDE BACKING BEHIND ALL SURFACE MOUNTED EQUIPMENT AND/OR FIXTURES PER DETAIL XX/XXXX

GENERAL NOTE - FLOOR PLAN

A201

2

A253

1

4

2

3

23' - 8 1/4"

DA201

3

A201

1

A201

4

1A301

2

A301

3

A301

4

A301 A4011

A4013

A4511

A4512

KITCHEN101

STORAGE102

W.H. / FURNACE/FIRERISER103

ELEC.104

CLASSROOM105CLASSROOM

106

ELEV. EQUIP.107

ELEV.108

CLASSROOM109

GYM112

MENS113

WOMENS114

JAN115

A/V CONTROL116

CORRIDOR119

VESTIBULE121

SANCTUARY123

FOYER125

A4513

VESTIBULE126

STORAGE127

113 114

126a

123d

112c

123a

101a

123c

104103b

106 105

109 116

115

107

121a

126b

103a

112b

127

112a

L

J

K

F

M M

108a

A611

11

128

STORAGE128

Q

121b

1 2 3 4

B

E

A

18' -

7"

33' -

0"

24' -

4"

40' - 0" 23' - 4" 41' - 7" 41' - 2"

XM81

XM81

XW60.1

XM81

XM81

XM81

XW60.1

W66W66

W46

W46

W66A

W46

W46

W46

W46

W46

XW60.1

W61

XM81

W41W46W46

S38

W46A

W46A

XM80

XM80 XM80

W46A

W46A

W46A

W46A

W48

W48

W48

W48

XW60.1

W46

S38

S38

S38

XM81

W41

XW60.1

XM81

W28

W28

W28

W28

S38

S37

W66 W46

W41

W46

XM80

W28

W28XM81

XM81 XM61XM81 XM61XM81 XM61XM81XM81 XM61

XM81

XM81

XM61

S38AS38AS38A

W41

W48

XM61

W28

N

W46

XM61

12:WS2

W4W

3' - 6" A.F.F.

0' - 6" A.F.F.

S38A

S38A S38A S38A S38A

10:BG2

C

5

102101b 101c

22:DF1

10:FC1

10:FC1

RAMP

RAMP

06:WR106:WR1

06:WR106:WR1

1' - 0" A.F.F.

22:MS1

DATE:DRAWN BY:CHECKED BY:NEXUS PROJECT #:

Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, UT 84109T 801.924.5000 http://www.archnexus.com

Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.© Architectural Nexus, Inc. 2017

54321

D

C

B

A

5/1

7/2

018

10:4

7:1

0 A

M

FLOORPLAN

Author

1624 S

1000 W

SA

LT L

AK

E C

ITY

, U

T 8

4104

SA

MO

AN

IN

DE

PE

ND

EN

T S

EV

EN

TH

-DA

YA

DV

EN

TIS

T C

HU

RC

H

18030

05/17/18

SIS

DA

C U

TA

H

DESIGNDEVELOPMENT

A101

Checker1/8" = 1'-0"A101

1 LEVEL 01 - OVERALL FLOOR PLAN

# Date Revision

KEYNOTE LEGEND

Key Value Keynote Text

06:WR1 WOOD HANDRAILAND GUARDRAIL

10:BG2 PORCELAIN TILEBAPTISMAL FONTWITH REMOVABLECOVER. WATERPROOFING W/DRAINAGE MAT.

10:FC1 FIRE EXTINGUISHERCABINET - SEEDETAILS A3/A701.

12:WS2 FIXED WOOD PEW,TYP.

22:DF1 DRINKING FOUNTAIN

22:MS1 MOP SINK

Page 11: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

REF.

UP

UP

DW

ELEV.

OPEN TO BELOW

OPEN TO BELOW

OPEN TO BELOW

W/D.

A201

2

LIVING AREA

214

CLOSET

204

MECH

205

RESTROOM

206

RESTROOM

207

RESTROOM

208

MECH.

209

OFFICE

210

OFFICE & COPY AREA

211

CONFERENCE ROOM

202

CORRIDOR

203

FOYER

125

A253

1

4

2

323' - 8 1/4"

DA201

3

A201

1

A201

4

1

A301

2

A301

3

A301

4

A301

A401

2

A401

4

STORAGE

212

MECH.

213215a

214a

216b

202a

218217

206

207

215b

204

210

209

208

219

211

205

212 213

203

BEDROOM

215BEDROOM

216

BATHROOM

217

BATHROOM

218

BBBA

BBBB

B

D

D

D DE

F

G

H

A611

2

202b

1 2 3 4

40' - 0" 23' - 4" 41' - 7" 41' - 2"

B

E

A

XM81

XM81

XW60.1

XM81

XM81

XM81

XW60.1

XM81

W48

W66

W46

W46

W66

XM81

W46

W66

W41

W41

W46

W46

W66

W41

W66

W46A

S38

W46

W46

W46

W46

XM80

XM80

XM80

W48

W48

W48

W48

W46A

XW60.1

XW60.1

S38

S38

S38

W46

W46

W46

W66

W46

W48

XM81

XW60.1

W46

XM40

XM40

XM81

W41

W46

XM81

W41

W46A

W48

W28

W28

S38

S37XM80

W28

W41

W48

W48

W48

W48

XM40

XM81

XM40

XM40XM81XM81XM40 XM81XM81XM81

XM81

XM81

S38AS38A

W48

W28

W28

W46

40' - 0" 23' - 4" 11' - 7 111/256" 5' - 4" 7' - 8" 5' - 4" 7' - 8" 5' - 4" 7' - 8" 5' - 4" 26' - 9 145/256"

5' - 4"

W28

W28

B

S38A

S38AS38A

S38A S38A S38A S38A

202d

202c

C

18' -

7"

8' -

8"

24' -

4"

24' -

4"

5

XM40XM40XM81

6' -

0"

3' -

4"

38' -

8"

3' -

4"

6' -

0"

STORAGE

219

10:RH2

214b

108b

E E E

C

10:FC1

10:FC1

W61

W46W46

DATE:DRAWN BY:CHECKED BY:NEXUS PROJECT #:

Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, UT 84109T 801.924.5000 http://www.archnexus.com

Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.© Architectural Nexus, Inc. 2017

54321

D

C

B

A

5/1

7/2

018

11:0

6:0

6 A

M

FLOOR

PLAN

Author

1624 S

1000 W

SA

LT L

AK

E C

ITY

, U

T 8

4104

SA

MO

AN

IN

DE

PE

ND

EN

T S

EV

EN

TH

-DA

Y

AD

VE

NTIS

T C

HU

RC

H

18030

05/17/18

SIS

DA

C U

TA

H

DESIGN

DEVELOPMENT

A102

Checker

1/8" = 1'-0"A102

1 LEVEL 02 - OVERALL FLOOR PLAN

# Date Revision

Page 12: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

A. COORDINATE GRADING SHOWN ON ELEVATIONS w/ CIVIL

B. PROVIDE GUTTERS AND DOWN SPOUTS w/ HEAT CABLE, SNOW FENCES, AND SNOW CLIPS - SEE ROOF PLAN

C. FOR TYPICAL WALL ASSEMBLY INCLUDING MATERIAL DESIGNATIONS AND DETAILING APPROACH, SEE A350 SERIES

GENERAL NOTE -

BUILDING ELEVATION

ROOF120' - 6"

LEVEL 01100' - 0"

LEVEL 02111' - 0"

LOWER PARAPET123' - 6"

3

A301

4

A301

MID PARAPET126' - 6"

UPPER PARAPET130' - 0"

BORAL TRUEXTERIOR SIDING;PAINTED

BORAL TRUEXTERIOR SIDING;PAINTED

BRICK VENEER BRICK VENEER

STRUCTURAL MASONRY (ATLAS BLOCK)SEE STRUCTURAL FOR SIZE

ALUMINUM WINDOW SYSTEM

1234

J

B B B

A

B B B B

L

B

5

PARAPET CAP FLASHINGPARAPET CAP FLASHING PARAPET CAP FLASHINGPARAPET CAP FLASHING

THRU-WALL SCUPPER

THRU-WALL SCUPPER WITHPRE-FINISHED CONDUCTOR, HEADAND DOWNSPOUT

THRU-WALL SCUPPER WITHPRE-FINISHED CONDUCTOR, HEADAND DOWNSPOUT

THRU-WALL SCUPPER WITHPRE-FINISHED CONDUCTOR, HEADAND DOWNSPOUT

E METAL ACCENT BAND

XM61

ROOF120' - 6"

LEVEL 01100' - 0"

LEVEL 02111' - 0"

LOWER PARAPET123' - 6"

3A301

4A301

MID PARAPET126' - 6"

UPPER PARAPET130' - 0"

BRICK VENEER

STRUCTURAL MASONRY (ATLASBLOCK) SEE STRUCTURAL FOR SIZE

STRUCTURAL MASONRY (ATLASBLOCK) IN BRICK MODULE. SEESTRUCTURAL FOR SIZE

BORAL TRUEXTERIOR SIDING;PAINTED

1 2 3 4

D D

M M

EEEE

5

PARAPET CAP FLASHING

PARAPET CAP FLASHING

6' -

0"

8' -

4"

THRU-WALL SCUPPER WITHPRE-FINISHED CONDUCTOR, HEAD

AND DOWNSPOUT

THRU-WALL SCUPPER THRU-WALL SCUPPER

XM61 XM61 XM61 XM61 XM61 XM61

ROOF120' - 6"

LEVEL 01100' - 0"

LEVEL 02111' - 0"

LOWER PARAPET123' - 6"

MID PARAPET126' - 6"

UPPER PARAPET130' - 0"

BRICK VENEERSTRUCTURAL MASONRY (ATLASBLOCK) SEE STRUCTURAL FOR SIZE

BORAL TRUEXTERIOR SIDING;PAINTED

FIBER CEMENT BOARD PANEL

ALUMINUM WINDOW SYSTEMALUMINUM WINDOW SYSTEMH

K

F

METAL CLAD CROSS

PARAPET CAP FLASHING

PARAPET CAP FLASHING

METAL ACCENT BAND

ROOF120' - 6"

LEVEL 01100' - 0"

LEVEL 02111' - 0"

D

LOWER PARAPET123' - 6"

1

A301

2

A301

MID PARAPET126' - 6"

UPPER PARAPET130' - 0"

BORAL TRUEXTERIOR SIDING;PAINTED STRUCTURAL MASONRY (ATLAS

BLOCK) IN BRICK MODULE. SEESTRUCTURAL FOR SIZE

B EA

B

D D

C

PARAPET CAP FLASHING PARAPET CAP FLASHING

THRU-WALL SCUPPER WITHPRE-FINISHED CONDUCTOR, HEAD

AND DOWNSPOUT

THRU-WALL SCUPPER WITHPRE-FINISHED CONDUCTOR, HEADAND DOWNSPOUT

METAL ACCENT BAND

XM61XM61

DATE:DRAWN BY:CHECKED BY:NEXUS PROJECT #:

Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, UT 84109T 801.924.5000 http://www.archnexus.com

Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.© Architectural Nexus, Inc. 2017

54321

D

C

B

A

5/1

7/2

018

11:4

6:3

7 A

M

BUILDING

ELEVATIONS

Author

1624 S

1000 W

SA

LT L

AK

E C

ITY

, U

T 8

4104

SA

MO

AN

IN

DE

PE

ND

EN

T S

EV

EN

TH

-DA

Y

AD

VE

NTIS

T C

HU

RC

H

18030

05/17/18

SIS

DA

C U

TA

H

DESIGN

DEVELOPMENT

A201

Checker

1/8" = 1'-0"A201

1 NORTH ELEVATION

1/8" = 1'-0"A201

2 SOUTH ELEVATION

1/8" = 1'-0"A2013 EAST ELEVATION

1/8" = 1'-0"A2014 WEST ELEVATION

# Date Revision

Page 13: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

A. ENSURE THAT ALL REQUIRED FIXTURE AND CABINET CLEARANCES AND OTHER REQUIREMENTS ARE MAINTAINED PURSUANT TO ADAAG AND ANSI A117.1. SEE SHEET G701 FOR GENERAL GUIDANCE ON COMMON MOUNTING HEIGHTS.

B. PROVIDE BLOCKING/BACKING AS NECESSARY FOR MOUNTING OF WALL-MOUNTED CABINETS, FIXTURES AND EQUIPMENT PER MANUFACTURERS RECOMMENDATIONS. COORDINATE THIS REQUIREMENT THROUGH ALL FLOOR PLANS, EQUIPMENT PLANS, AND INTERIOR ELEVATIONS.

C. ON ALL EXPOSED CABINET SIDES, INCLUDING KNEE OPENINGS, PROVIDE FINISHED FACE TO MATCH CABINET FRONTS . PROVIDE SIDESPLASHES WHENEVER COUNTERTOPS ARE ADJACENT TO WALLS.

GENERAL NOTE -

INTERIOR ELEVATION

PORCELAIN TILE BAPTISMAL FONTWITH REMOVABLE COVER. WATERPROOFING W/ DRAINAGE MAT.

ACOUSTIC PLASTER FINISH APPLIEDTO (1) LAYER 5/8" GYPSUM BOARDACOUSTIC PLASTER FINISH APPLIEDTO (1) LAYER 5/8" GYPSUM BOARD

ACOUSTIC PLASTERFINISH APPLIED TO

(1) LAYER 5/8"GYPSUM BOARD

ACOUSTIC PLASTERFINISH APPLIED TO

(1) LAYER 5/8"GYPSUM BOARD

ALTERNATE: ACOUSTIC WALL PANELS

ALTERNATE: ACOUSTIC WALL PANELS

MOTORIZED WINDOW SHADES

WOOD HANDRAIL AND GUARDRAIL

ACOUSTIC PLASTER FINISH APPLIEDTO (1) LAYER 5/8" GYPSUM BOARDACOUSTIC PLASTER FINISH APPLIEDTO (1) LAYER 5/8" GYPSUM BOARDACOUSTIC PLASTER FINISH APPLIEDTO (1) LAYER 5/8" GYPSUM BOARD

ACOUSTIC PLASTER FINISH APPLIEDTO (1) LAYER 5/8" GYPSUM BOARD

ALTERNATE: ACOUSTIC WALL PANELS

ALTERNATE: ACOUSTIC WALL PANELS

TYPICAL ALL WINDOWS IN SANCTUARY

MOTORIZED WINDOW SHADES

WOOD HANDRAIL AND GUARDRAIL

6' - 0"

N

PP

SOLA TUBE FIXTURE

SOLA TUBE FIXTURE

ACOUSTIC PLASTER FINISHAPPLIED TO (1) LAYER 5/8"

GYPSUM BOARD

ALTERNATE: ACOUSTIC WALL PANELS

METAL CLAD CROSS

SOLA TUBE FIXTURESOLA TUBE FIXTUREMOTORIZED WINDOW SHADES

DATE:DRAWN BY:CHECKED BY:NEXUS PROJECT #:

Architectural NEXUS, Inc.2505 East Parleys WaySalt Lake City, UT 84109T 801.924.5000 http://www.archnexus.com

Original drawings remain the property of the Architect and as such the Architect retains total ownership and control. The design represented by these drawings is sold to the client for a one time use, unless otherwise agreed upon in writing by the Architect.© Architectural Nexus, Inc. 2017

54321

D

C

B

A

5/1

7/2

018

11:5

5:3

3 A

M

INTERIOR

ELEVATIONS

Author

1624 S

1000 W

SA

LT L

AK

E C

ITY

, U

T 8

4104

SA

MO

AN

IN

DE

PE

ND

EN

T S

EV

EN

TH

-DA

Y

AD

VE

NTIS

T C

HU

RC

H

18030

05/17/18

SIS

DA

C U

TA

H

DESIGN

DEVELOPMENT

A253

Checker

# Date Revision

1/4" = 1'-0"A2531 123 - NORTH

1/4" = 1'-0"A253

2 123 - SOUTH

1/4" = 1'-0"A2533 123 - WEST

1/4" = 1'-0"A2534 123 - EAST

Page 14: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 6

ATTACHMENT D: APPLICANT INFORMATION

The narrative found on the following pages was submitted by the applicant.

GD9464
Rectangle
Page 15: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

1

Samoan Independent Seventh Day Adventist Church

The Samoan Independent Seventh Day Adventist Church (SISDAC) is currently located on the site referenced in this proposal at 1624 South 1000 West, Salt Lake City, UT 84104. The existing building was not designed for the needs of this congregation and has outlived its useful life. Therefore, SISDAC would like to replace the building with new construction with a similar program. Places of worship are accommodated in an RMF-35 Moderate Density Multi-Family Residential District as conditional uses, which is the purpose of this application.

The proposed project is a two story church building. It includes a sanctuary space, a post-function/gym space, auxiliary conference room, office and support spaces and a two bedroom residential unit for occasional occupancy by visiting clergy.

The service and operation of the building will continue as it currently stands.

The site to the north is occupied by another church, the Serbian Orthodox Church. The site to the west is occupied by a multi-family residential building. The sites to the south and east (across the street) are occupied by single /two family residential buildings.

There are no shift workers in this building, and there will likely be 3-4 employees in the building at any one time.

The sanctuary holds approximately 250-260 people and the post-function space holds approximately 150-160 people, but they would not be occupied concurrently.

All the required setbacks and landscape buffers required are being met.

Site plans, building plans and elevations are attached

ARCHITECTURAL NEXUS, Inc archnexus.com

SALT LAKE CITY

2505 East Parleys Way Salt Lake City, Utah 84109

T 801.924.5000

SACRAMENTO

1990 Third Street, Suite 500

Sacramento, California 95811

T 916.443.5911

Page 16: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 7

ATTACHMENT E: EXISTING CONDITIONS & ZONING ORDINANCE REQUIREMENTS

ADJACENT LAND USES and ZONING

The land use and zoning surrounding the site include the following:

North: RMF-35 – contains the Serbian Orthodox Church. Further north is R-2 – developed for a variety of residential uses, both single and two-family.

South: RMF-35 – residential uses on the same side of the street. On the opposite side of 1000 West to the south zoning changes to CB and across 1700 South the zoning is CG. Along this corridor the uses are more industrial in nature.

East: R-1/7000 – single family residential uses

West: RMF-35 – multi-family residential use SALT LAKE CITY ZONING ORDINANCE PROVISIONS 21A.24.130: RMF-35 MODERATE DENSITY MULTI-FAMILY RESIDENTIAL DISTRICT:

A. Purpose Statement: The purpose of the RMF-35 Moderate Density Multi-Family Residential District is to provide an environment suitable for a variety of moderate density housing types, including single-family, two-family, and multi-family dwellings with a maximum height of thirty five feet (35'). This district is appropriate in areas where the applicable Master Plan policies recommend a density of less than thirty (30) dwelling units per acre. This district includes other uses that are typically found in a multi-family residential neighborhood of this density for the purpose of serving the neighborhood. Uses are intended to be compatible with the existing scale and intensity of the neighborhood. The standards for the district are intended to provide for safe and comfortable places to live and play, promote sustainable and compatible development patterns and to preserve the existing character of the neighborhood.

Current Zoning Requirements – RMF-35 – Moderate Density Multi-Family Residential District

Zoning Standard Required Existing/Proposed Status

Min Lot Area 12,000 sq. ft. 33,000 sq. ft. Complies

Min Lot width 140’ 185’ Complies

Maximum Building Height

35’ 30’ Complies

Front Yard Setback 20’ 20’ Complies

Interior Side Yard 10’ 10’ on one side and over 50’ on the other

Complies

Rear Yard 25% of lot depth but not less than 20’ and need not exceed

25’

25’ is smallest Complies

Page 17: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 8

Parking Spaces 19 standard spaces and 2 ADA spaces

20 standard spaces and 2 ADA spaces

Complies

Landscape yard required - front

20’ 20’ Complies

Landscape yard required – interior side

10’ 10’ Complies

Landscape yard required - rear

20’ 20’ Complies

Maximum building coverage

60% of lot area Approximately 27% Complies

GD9464
Rectangle
Page 18: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 9

ATTACHMENT F: ANALYSIS OF STANDARDS 21A.54.080 Standards for Conditional Use Approval Standards: A conditional use shall be approved unless the planning commission, or in the case of administrative conditional uses, the planning director or designee, concludes that the following standards cannot be met: 1. The use complies with applicable provisions of this title;

Analysis: The property is located in the RMF-35 (Medium Density Multi Family Residential) zoning district. Per Section 21A.33.020 – Table of Permitted and Conditional Uses for Residential Districts of the Zoning Ordinance, all places of worship in the RMF-35 zone require conditional use approval. Finding: The proposal complies with the applicable provisions of the Salt Lake City Zoning Ordinance. It is allowed in the zone through the conditional use process and complies with all City requirements for such a facility.

2. The use is compatible, or with conditions of approval can be made compatible, with surrounding uses; Analysis: Surrounding uses include another place of worship as well as residential uses, both single and multi-family in nature. The proposed use is replacing an established use on the property with the same use but in an upgraded facility. The new facility is expected to continue to work compatibly within the context of its location and the size and scale fit in with the existing development.

Finding: Staff finds that the use and the scale and intensity of development will be compatible with surrounding uses.

3. The use is consistent with applicable adopted city planning policies, documents, and master plans; and

Analysis: The maps in the Westside Master Plan (2014) show that the subject property is located within close proximity to what is envisioned as a smaller regional node near the intersection of 900 West and 1700 South. This node is envisioned to support educational and professional office uses along with supporting commercial retail and services which would act as a transition between residential uses to the north and industrial uses to the south. The use is already established within the neighborhood and is in concert with the Master Plan and the anticipated character of the area over time.

Finding: The proposal does not present a conflict with the Master Plan.

4. The anticipated detrimental effects of a proposed use can be mitigated by the imposition of reasonable

conditions (please refer to Detrimental Impacts Chart on the next page for details).

Page 19: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 10

21a.54.080B Detrimental Effects Determination In analyzing the anticipated detrimental effects of a proposed use, the planning commission shall determine compliance with each of the following:

Criteria Finding Rationale 1. This title specifically authorizes the use where it is located

Complies A place of worship such as a church is allowed as a conditional use in the RMF-35 zoning district.

2. The use is consistent with applicable policies set forth in adopted citywide, community, and small area master plans and future land use maps

Complies The Westside Master Plan recognizes that places of worship across many faiths are distributed throughout neighborhood areas and are part of the assets and resources of the community. The proposed use is in concert with the Master Plan.

3. The use is well-suited to the character of the site, and adjacent uses as shown by an analysis of the intensity, size, and scale of the use compared to existing uses in the surrounding area

Complies The proposed use will replace an existing church of similar size and location on the site. The surrounding area includes a mix of multi and single family residential uses as well as another church immediately to the north of the subject property. The mass and scale is very similar to what could be potentially built by right in the RMF-35 zoning district.

4. The mass, scale, style, design, and architectural detailing of the surrounding structures as they relate to the proposed have been considered

Complies The proposed church is approximately 30-feet tall, which is less than the maximum height allowed in the zoning district. The proposed design does not maximize the allowable height or maximize the site coverage. As such, it will fit in with the existing development in the area in terms of mass and scale.

5. Access points and driveways are designed to minimize grading of natural topography, direct vehicular traffic onto major streets, and not impede traffic flows

Complies There are 3 existing access drives onto 1000 West from the property. The 3rd access drive is located to the south of the church and is unused. It will be abandoned and the curb cut will be replaced with curb and gutter and landscaping. The access points and driveway will not impede traffic flows.

6. The internal circulation system is designed to mitigate adverse impacts on adjacent property from motorized, non-motorized, and pedestrian traffic

Complies The internal site circulation includes an entrance and exit driveway which will allow traffic to flow through the parking area smoothly. There are no anticipated detrimental impacts on adjacent properties from the internal circulation on this site.

7. The site is designed to enable access and circulation for pedestrian and bicycles

Complies There is existing sidewalk on 1000 W, part of which will be replaced with this project that will provide pedestrian access to the site. In addition, the Transportation Division has indicated that one bicycle rack will be required on the site. The site will enable access for both pedestrians and bicycles.

8. Access to the site does not unreasonably impact the service level of any abutting or adjacent street

Complies The proposed use is anticipated to be low volume in nature and will not impact the service levels on 1000 West. On the subject property, it recommended that the property owner replace the public sidewalk along 1000 West which is in poor condition.

9. The location and design of off-street parking complies with applicable standards of this code

Complies The proposed parking will consist of 20 standard parking stalls and 2 ADA accessible spaces. Based on the building floor area for congregation space, offices space and the residential use, a total of 19

Page 20: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 11

parking spaces and 2 ADA accessible spaces would be required. The RMF-35 zoning district would allow for parking that is 25% greater than the minimum. The extra space is allowable and the parking meets the applicable standards.

10. Utility capacity is sufficient to support the use at normal service levels

Complies The site is within a developed area with all utility infrastructure in place. The site currently has both water and sewer service. Salt Lake City Public Utilities has been involved in the review process and will work through the building permit process to ensure that the utility infrastructure is adequate for the proposed facility.

11. The use is appropriately screened, buffered, or separated from adjoining dissimilar uses to mitigate potential use conflicts

Complies The proposed landscaping buffers meet the requirements of the RMF-35 zoning district.

12. The use meets City sustainability plans, does not significantly impact the quality of surrounding air and water, encroach into a river or stream, or introduce any hazard or environmental damage to any adjacent property, including cigarette smoke

Complies There is no indication that the proposed project will introduce any environmental damage to the surrounding area.

13. The hours of operation and delivery of the use are compatible with surrounding uses

Complies Aside from Sunday service hours, the church will host activities throughout the week as part of their programming for congregation members. The anticipated hours of normal operation will be compatible with surrounding uses.

14. Signs and lighting are compatible with, and do not negatively impact surrounding uses

Complies Any signs and lighting will be confined to that necessary to provide safety on the site including for adequate security while being minimized in order to not impact adjacent properties.

15. The proposed use does not undermine preservation of historic resources and structures

Complies There are no historic resources or structures on this site or in the surrounding area.

Finding: In analyzing the anticipated detrimental effects of the proposed use, Planning Staff finds that the request complies with the criteria listed above.

GD9464
Rectangle
Page 21: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 12

ATTACHMENT G: PUBLIC PROCESS AND COMMENTS

Public Notice, Meetings, Comments The following is a list of public meetings that have been held, and other public input opportunities, related to the proposed project:

Notice of the project and request for comments sent to the Chair of the Glendale Community Council (GCC) on May 29, 2018 in order to solicit comments.

Staff sent an early notification announcement of the project to all residents and property owners living within 300 feet of the project site on May 29, 2018 providing notice about the project and information on how to give public input on the project.

The 45-day recognized organization comment period expired on July 13, 2017. Notice of the public hearing for the proposal included:

Public hearing notice mailed on: July 26, 2018

Public hearing notice sign posted on the property: July 26, 2018

Public notice posted on City and State websites & Planning Division list serve: July 26, 2018 Public Input: The Glendale Community Council Chair did not ask staff to attend a meeting to present the project. No additional public comments were submitted for this proposal from any neighboring property owners or residents.

GD9464
Rectangle
Page 22: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 13

ATTACHMENT H: DEPARTMENT REVIEW COMMENTS The following comments from other reviewing departments were submitted in relation to the proposal: PUBLIC UTILITIES COMMENTS

Utilities to the neighboring property go through this property. Easements and protection of these utilities is required.

Minimum separation requirements must be met. 10’ between water and sewer. 5’ from sewer to all other utilities and buildings and property lines. 3’ from water to all other utilities. 5’ from water to buildings and property lines. Water meters must have 5’ clearance around the meter.

Utilities cannot cross property lines without appropriate easements and agreements.

All utility design and construction must comply with APWA Standards and SLCPU Standard Practices.

ENGINEERING COMMENTS No objections to the conditional use. It is recommended that the badly cracked public sidewalk in 1000 West be replaced as part of this project. FIRE REVIEW COMMENTS Fire would have NO objections to the conditional use petition (PLNPCM2018-00372) for the proposed new Samoan Independent 7th Day Adventist Church to be located at 1624 South 1000 West. The proposed new 2-story, 30 feet or taller, church building with sanctuary space, multi-function/gym space, conference room, office and support spaces and a residential unit, shall be provided with an approved means of fire access; and fire flow, in accordance with IFC and the Appendices (including but not limited to the burial of the overhead utilities).

TRANSPORTATION COMMENTS It appears that parking calculations and parking dimensions are acceptable. One bike rack will be required. ZONING REVIEW COMMENTS 1. The uses specified as conditional uses in section 21A.33.020, "Table Of Permitted And Conditional Uses For

Residential Districts", of this title shall be allowed provided they are approved pursuant to the standards and procedures for conditional uses set forth in chapter 21A.54 of this title, and comply with all other applicable requirements of this title [21A.24.010 D].

a. The residential unit for occasional occupancy by visiting clergy appears to be along the lines of a hotel/motel, or a dwelling unit for accessory guest & servants quarters, neither of which are permitted in the RMF-35 zoning district.

b. This new development proposal appears to represent a single parcel development which intends to use the adjacent 1612 S 1000 West parcel for parking and maneuvering. Off-site parking is not a permitted use in this RMF-35 zoning district, and therefore; consolidation of the two (2) parcels is required.

2. To maintain architectural harmony and primary orientation along the street, all buildings shall be required to include an entrance door, and such other features as windows, balconies, porches, and other such architectural features in the front facade of the building, totaling not less than ten percent (10%) of the front facade elevation area, excluding any area used for roof structures [21A.24.010 I].

3. On site lighting shall be located, directed or designed in such a manner as to contain and direct light and glare only to the property on which it is located [21A.24.010 K].

4. All uses in the residential districts shall comply with the provisions governing off street parking in chapter 21A.44 of this title [21A.24.010 L].

a. The Parking Data provided does not address the residential unit for occasional occupancy by visiting clergy.

Page 23: Staff Report Commission/2018/0808SAC.SR.pdfAug 08, 2018  · SAMOAN INDEPENDENT SEVENTH 1624 S 1000 W SALT LAKE CITY, UT 84104-DAY ADVENTIST CHURCH 18030 05/17/18 SISDAC UTAH DESIGN

PLNPCM2018-00372 – Samoan Independent 7th Day Adventist Church 14

b. The Parking Data provided identifies the “Building Footprint” rather than the FLOOR AREA, GROSS as defined in 21A.62 for determining off street parking and loading requirements and therefore; an inaccurate conclusion has likely been reached.

c. The Parking Data provided has not indicated the maximum parking allowed, bicycle parking required/provided outside of the building and within 50’ of the principle entry, nor any method used for reducing or increasing the parking requirement if appropriate.

5. In accordance with 21A.44.020 F.7.a (2), except for entrance and exit driveways leading to properly located parking areas, no curb cuts or driveways are permitted. The existing unused curb cut will need to be replaced with curb & gutter and appropriate landscaping.

6. All required front and corner yards should be maintained as landscape yards. In addition, all uses in residential districts shall comply with the provisions governing landscaping in chapter 21A.48 [21A.24.010 O]. Compliance, or noncompliance to this, and the interior side yard landscaping requirement of 21A.24.130 F is to be documented for processing through the conditional use process.

7. The maximum building height permitted in this district is thirty five feet (35'). Compliance, or noncompliance is to be documented on each face of each building for processing through the planned development process.

8. Any fences, walls and hedges, as well as any ground mounted utility boxes are to be consistent with 21A.40.