s:q12 9 hemans john boggiadrawingsq12 9 hemans - opt 6 ... · 15.provide fire extinguishers per...

7
UP UP DN WD1 W1 CT1 101 ROOM NAME ROOM FINISH KEY CONTRACT LIMIT LINE EXISTING DOOR NEW DOOR PARTITIONS, DOORS AND ITEMS TO BE REMOVED FULL HEIGHT PARTITION PARTIAL HEIGHT PARTITION DIMENSION TO THE FACE OF FRAMING OR MASONRY AT NEW CONSTRUCTION, TYP. DIMENSION TO THE FACE OF FINISH AT EXISTING CONSTRUCTION DIMENSION TO THE FACE OF FINISH EXISTING PARTITION 1. VERIFY ALL DIMENSIONS IN THE FIELD. DO NOT SCALE DRAWINGS. 2. ALL INTERIOR WALLS 2X4 AT 16" O.C. UNLESS NOTED OTHERWISE. PROVIDE DOUBLE TOP PLATES. SEE B4/A0.0 3. ALL DOOR JAMBS 4" OFF WALL UNLESS NOTED OTHERWISE 4. CENTER DOORS IN WALL UNLESS NOTED OTHERWISE 5. PROVIDE HARDWIRED AND INTERCONNECTED SMOKE AND CO DETECTORS WITH BATTERY BACKUP PER CODE REQUIREMENTS & AS DIRECTED BY THE LOCAL BUILDING DEPT. 6. PROTECT IN PLACE ALL EXISTING FIXTURES AND SURFACES SCHEDULED TO REMAIN. 7. PATCH AND REPAIR EXISTING WALLS LOCATED IN UNALTERED AREAS AFFECTED BY ALL NEW WORK, WHETHER SHOWN ON THE DRAWINGS OR NOT. 8. PATCH, PAINT AND REFINISH ALL EXISTING WALLS, FLOORS, CEILINGS & TRIM THROUGHOUT REPLACE MATERIALS IN - KIND WHEN DAMAGED PAST POINT OF REPAIR. 9. PLANS DO NOT FULLY REPRESENT ALL NEW WORK. THE CONSTRUCTION DOCUMENTS ARE INTENDED TO TO SERVE AS GENERAL GUIDELINES. 10. DIMENSIONS SHOWN ARE FROM FACE OF STUD OR FACE OF EXISTING CONSTRUCTION UNLESS NOTED OTHERWISE. GENERAL NOTES 11. PROVIDE ELECTRICAL PER STATE ELECTRICAL CODE REQUIREMENTS. PROVIDE POWER FOR ALL APPLIANCES. LOCATE NEW ELECTRICAL DEVICES PER NEC REQUIREMENTS & OWNER'S REQUIREMENTS. 12. PROVIDE PLUMBING PER STATE PLUMBING CODE REQUIREMENTS 13. HVAC SYSTEM TO BE DESIGN BUILD, PROVIDE PER STATE CODE REQUIREMENTS. 14. PROVIDE SOLID WOOD BLOCKING AS REQUIRED. 15. PROVIDE FIRE EXTINGUISHERS PER CODE AND PER REQUIREMENTS OF THE BUILDING OFFICIAL. 16. INSTALL BATT INSULATION FULL DEPTH AT ALL EXPOSED STUD CAVITIES (CLOSED CELL SPRAY FOAM AT ATTIC ROOF CAVITIES) 17. COVER ALL WALLS AND CEILINGS W/1/2" THICK GYPSUM BOARD UNLESS NOTED OTHERWISE. 18. PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM BOARD AT BATHROOMS UNLESS NOTED OTHERWISE. 19. ALL APPLIANCES PROVIDED BY OWNER, INSTALLED BY CONTRACTOR. 20. RECONNECT EXISTING FIXTURES TO NEW SWITCH LOCATIONS AS REQUIRED IN THE FIELD. 21. PROVIDE DIMMERS AS DIRECTED BY OWNER 22. A/V, CATV, TELEPHONE AND OTHER LOW VOLTAGE WIRING NOT SHOWN. SYSTEM TO BE DESIGN/BUILD. CONTACT OWNER FOR LOCATIONS OF ALL LOW VOLTAGE WIRING. PLAN LEGEND A5.1 2 A5.0 A5.1 1 A4 1 3 4 5 2 6 7 8 9 D C B A 23' - 0" 15' - 6" 23' - 0" 21' - 10" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 21' - 10" 187' - 8" 61' - 6" 1 HC 3 4 5 6 7 604' - 0" 605' - 7" 609' - 3" 317 SF TRASH 175 SF METERS 149 SF STAIR 1 386 SF SERVICE CORRIDOR 136 SF RATED EXIT CORRIDOR 11 SF CLO 249 SF SERVICE MAILBOXES 1" / 1'-0" RAMP 1" / 1'-0" RAMP 1" / 1'-0" RAMP 600 SF ENTRY 578 SF TENANT STORAGE 234 SF BIKE STORAGE 149 SF STAIR 2 ELEV 1 PLANTER A5.2 1 606' - 9" 604' - 0" 604' - 0" UNEXCAVATED SPACE 2 PROJECT NUMBER: DAVID SISSON ARCHITECTURE PC --- ALL RIGHTS RESERVED d a v i d s i s s o n a r c h i t e c t u r e pc 238 Fifth Street Providence RI 02906 www.ds - arch.com 401 - 595 - 7070 A B C D 1 2 3 4 SCHEMATIC DESIGN ONLY NOT FOR CONSTRUCTION A4.0 B A S E M E N T ( L 0 ) P L A N 16112 9 H e m a n s Worcester, MA 01605 KEYED NOTES 1/8" = 1'-0" A4 FLOOR PLAN - L0 D A T E : IS S U E D F O R : 2 0 1 7 - 0 5 - 2 3 S C H E M A T I C D E S I G N UNIT COUNTS 1 BR UNITS = 540 GSF 2 BR = 805 GSF 2 BR/CORNER = 925 GSF LEVEL 0 = PARKING (7 SPOTS) & BUILDING SERVICES LEVEL 1 = 8 UNITS (6 @ 2BR, 2 @ 1 BR), PARKING (7 SPOTS) & BUILDING SERVICES LEVEL 2 = 12 UNITS (8 @ 2BR, 4 @ 1 BR) LEVEL 3 = 12 UNITS (8 @ 2BR, 4 @ 1 BR) LEVEL 4 = 12 UNITS (8 @ 2BR, 4 @ 1 BR) LEVEL 5 = 12 UNITS (8 @ 2BR, 4 @ 1 BR) LEVEL 6 = 8 UNITS (6 @ 2BR, 2 @ 1 BR) TOTAL = 44 @ 2BR, 20 @ 1BR = 64 TOTAL UNITS

Upload: others

Post on 30-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • UP UP

    DN

    WD1W1

    CT1

    101ROOM NAME

    ROOM FINISH KEY

    CONTRACT LIMIT LINE

    EXISTING DOOR

    NEW DOOR

    PARTITIONS, DOORS AND ITEMS TO BE REMOVED

    FULL HEIGHT PARTITION

    PARTIAL HEIGHT PARTITION

    DIMENSION TO THE FACE OF FRAMING OR MASONRY AT NEW CONSTRUCTION, TYP.DIMENSION TO THE FACE OF FINISH AT EXISTING CONSTRUCTION

    DIMENSION TO THE FACE OF FINISH

    EXISTING PARTITION

    1.VERIFY ALL DIMENSIONS IN THE FIELD. DO NOT SCALE DRAWINGS.

    2.ALL INTERIOR WALLS 2X4 AT 16" O.C. UNLESS NOTED OTHERWISE. PROVIDE DOUBLE TOP PLATES. SEE B4/A0.0

    3.ALL DOOR JAMBS 4" OFF WALL UNLESS NOTED OTHERWISE

    4.CENTER DOORS IN WALL UNLESS NOTED OTHERWISE

    5.PROVIDE HARDWIRED AND INTERCONNECTED SMOKE AND CO DETECTORS WITH BATTERY BACKUP PER CODE REQUIREMENTS & AS DIRECTED BY THE LOCAL BUILDING DEPT.

    6.PROTECT IN PLACE ALL EXISTING FIXTURES AND SURFACES SCHEDULED TO REMAIN.

    7.PATCH AND REPAIR EXISTING WALLS LOCATED IN UNALTERED AREAS AFFECTED BY ALL NEW WORK, WHETHER SHOWN ON THE DRAWINGS OR NOT.

    8.PATCH, PAINT AND REFINISH ALL EXISTING WALLS, FLOORS, CEILINGS & TRIM THROUGHOUT REPLACE MATERIALS IN-KIND WHEN DAMAGED PAST POINT OF REPAIR.

    9.PLANS DO NOT FULLY REPRESENT ALL NEW WORK. THE CONSTRUCTION DOCUMENTS ARE INTENDED TO TO SERVE AS GENERAL GUIDELINES.

    10.DIMENSIONS SHOWN ARE FROM FACE OF STUD OR FACE OF EXISTING CONSTRUCTION UNLESS NOTED OTHERWISE.

    GENERAL NOTES 11.PROVIDE ELECTRICAL PER STATE ELECTRICAL CODE REQUIREMENTS. PROVIDE POWER FOR ALL APPLIANCES. LOCATE NEW ELECTRICAL DEVICES PER NEC REQUIREMENTS & OWNER'S REQUIREMENTS.

    12.PROVIDE PLUMBING PER STATE PLUMBING CODE REQUIREMENTS

    13.HVAC SYSTEM TO BE DESIGN BUILD, PROVIDE PER STATE CODE REQUIREMENTS.

    14.PROVIDE SOLID WOOD BLOCKING AS REQUIRED.

    15.PROVIDE FIRE EXTINGUISHERS PER CODE AND PER REQUIREMENTS OF THE BUILDING OFFICIAL.

    16.INSTALL BATT INSULATION FULL DEPTH AT ALL EXPOSED STUD CAVITIES (CLOSED CELL SPRAY FOAM AT ATTIC ROOF CAVITIES)

    17.COVER ALL WALLS AND CEILINGS W/1/2" THICK GYPSUM BOARD UNLESS NOTED OTHERWISE.

    18.PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM BOARD AT BATHROOMS UNLESS NOTED OTHERWISE.

    19.ALL APPLIANCES PROVIDED BY OWNER, INSTALLED BY CONTRACTOR.

    20.RECONNECT EXISTING FIXTURES TO NEW SWITCH LOCATIONS AS REQUIRED IN THE FIELD.

    21.PROVIDE DIMMERS AS DIRECTED BY OWNER

    22.A/V, CATV, TELEPHONE AND OTHER LOW VOLTAGE WIRING NOT SHOWN. SYSTEM TO BE DESIGN/BUILD. CONTACT OWNER FOR LOCATIONS OF ALL LOW VOLTAGE WIRING.

    PLAN LEGEND

    A5.12

    A5.0

    A5.1 1

    A4

    1 3 4 52 6 7 8 9

    D

    C

    B

    A

    23' -

    0"

    15' -

    6"

    23' -

    0"

    21' - 10" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 21' - 10"

    187' - 8"

    61' -

    6"

    1HC

    3 4 5 6 7

    604' - 0"605' - 7" 609' - 3"

    317 SFTRASH 175 SF

    METERS

    149 SFSTAIR 1

    386 SF

    SERVICECORRIDOR

    136 SF

    RATED EXITCORRIDOR

    11 SFCLO

    249 SFSERVICE

    MAILBOXES

    1" / 1'-0" RAMP 1" / 1'-0" RAMP 1" / 1'-0" RAMP

    600 SFENTRY

    578 SF

    TENANTSTORAGE

    234 SFBIKE STORAGE

    149 SFSTAIR 2

    ELEV 1

    PLANTER

    A5.2

    1

    606' - 9"

    604' - 0"

    604' - 0"

    UNEXCAVATED SPACE

    2

    PR

    OJE

    CT

    NU

    MB

    ER

    :

    DA

    VID

    SIS

    SO

    N A

    RC

    HIT

    EC

    TUR

    E P

    C --

    - ALL

    RIG

    HTS

    RE

    SE

    RV

    ED

    d a

    v i d

    s i

    s s

    o n

    a r

    c h

    i t e

    c t

    u r e

    pc

    238

    Fifth

    Stre

    etP

    rovi

    denc

    e R

    I 029

    06w

    ww

    .ds-

    arch

    .com

    401

    -595

    -707

    0

    A B C D

    1

    2

    3

    4

    SCHE

    MATIC

    DESIG

    N ONL

    Y

    NOT F

    OR

    CONS

    TRUC

    TION

    A4.0

    BASE

    MEN

    T(L

    0)P L

    AN16

    112

    9H

    e ma n

    sW

    orce

    ster

    , MA

    0160

    5

    KEYED NOTES

    1/8" = 1'-0"A4FLOOR PLAN - L0

    DAT

    E:IS

    S UED

    FOR:

    2017

    -05-

    23S

    CH

    EMAT

    ICD

    ESIG

    N

    UNIT COUNTS

    1 BR UNITS = 540 GSF2 BR = 805 GSF2 BR/CORNER = 925 GSF

    LEVEL 0 = PARKING (7 SPOTS) & BUILDING SERVICES LEVEL 1 = 8 UNITS (6 @ 2BR, 2 @ 1 BR),

    PARKING (7 SPOTS) & BUILDING SERVICESLEVEL 2 = 12 UNITS (8 @ 2BR, 4 @ 1 BR)LEVEL 3 = 12 UNITS (8 @ 2BR, 4 @ 1 BR)LEVEL 4 = 12 UNITS (8 @ 2BR, 4 @ 1 BR)LEVEL 5 = 12 UNITS (8 @ 2BR, 4 @ 1 BR)LEVEL 6 = 8 UNITS (6 @ 2BR, 2 @ 1 BR)

    TOTAL = 44 @ 2BR, 20 @ 1BR = 64 TOTAL UNITS

  • DN

    UP

    A5.12

    A5.0

    A5.1 1

    A4

    1 3 4 52 6 7 8 9

    D

    C

    B

    A

    131211108

    134 SFBR

    161 SFBR

    394 SFL/D/K 12 SF

    CLO

    11 SFCLO

    9 SFCLO38 SF

    BATH

    40 SFBATH

    134 SFBR

    161 SFBR

    393 SFL/D/K

    13 SFCLO

    11 SFCLO

    9 SFCLO

    38 SFBATH

    41 SFBATH

    123 SFBR

    265 SFL/D/K

    9 SFCLO

    8 SFCLO

    146 SFBR

    11 SFCLO

    253 SFL/D/K

    321 SFL/D/K

    46 SFBATH

    12 SFCLO

    121 SFBR

    40 SFBATH

    137 SFBR

    37 SFCLO

    62 SFBATH

    149 SFBR

    278 SFL/D/K

    36 SFCLO

    41 SFBATH

    124 SFBR

    9 SFCLO

    8 SFCLO

    62 SFBATH

    614' - 2"

    620' - 0"

    620' - 0"

    A5.2

    1

    9 14HC

    149 SFSTAIR 1

    149 SFSTAIR 2

    32 SFTRASH

    149 SFSTAIR 3

    1061 SFHALL

    56 SFELEV 1

    56 SFELEV 2

    11 SFCLO36 SF

    CLO38 SFBATH

    12 SFCLO

    134 SFBR

    128 SFBR

    315 SFL/D/K

    315 SFRoom

    145 SFBR

    150 SFBR

    27 SFCLO

    41 SFBATH

    60 SFBATH

    572 SF

    BUILDINGSERVICES

    242 SF

    RATED EXITCORRIDOR32 SF

    JANITOR

    PR

    OJE

    CT

    NU

    MB

    ER

    :

    DA

    VID

    SIS

    SO

    N A

    RC

    HIT

    EC

    TUR

    E P

    C --

    - ALL

    RIG

    HTS

    RE

    SE

    RV

    ED

    d a

    v i d

    s i

    s s

    o n

    a r

    c h

    i t e

    c t

    u r e

    pc

    238

    Fifth

    Stre

    etP

    rovi

    denc

    e R

    I 029

    06w

    ww

    .ds-

    arch

    .com

    401

    -595

    -707

    0

    A B C D

    1

    2

    3

    4

    SCHE

    MATIC

    DESIG

    N ONL

    Y

    NOT F

    OR

    CONS

    TRUC

    TION

    A4.1

    PLAN

    S-L

    1

    1611

    2

    9H

    e ma n

    sW

    orce

    ster

    , MA

    0160

    5

    1/8" = 1'-0"1FLOOR PLAN - L1

    DAT

    E:IS

    S UED

    FOR:

    2017

    -05-

    23S

    CH

    EMAT

    ICD

    ESIG

    N

  • UP

    DN

    UP

    DN

    WD1W1

    CT1

    101ROOM NAME

    ROOM FINISH KEY

    CONTRACT LIMIT LINE

    EXISTING DOOR

    NEW DOOR

    PARTITIONS, DOORS AND ITEMS TO BE REMOVED

    FULL HEIGHT PARTITION

    PARTIAL HEIGHT PARTITION

    DIMENSION TO THE FACE OF FRAMING OR MASONRY AT NEW CONSTRUCTION, TYP.DIMENSION TO THE FACE OF FINISH AT EXISTING CONSTRUCTION

    DIMENSION TO THE FACE OF FINISH

    EXISTING PARTITION

    1.VERIFY ALL DIMENSIONS IN THE FIELD. DO NOT SCALE DRAWINGS.

    2.ALL INTERIOR WALLS 2X4 AT 16" O.C. UNLESS NOTED OTHERWISE. PROVIDE DOUBLE TOP PLATES. SEE B4/A0.0

    3.ALL DOOR JAMBS 4" OFF WALL UNLESS NOTED OTHERWISE

    4.CENTER DOORS IN WALL UNLESS NOTED OTHERWISE

    5.PROVIDE HARDWIRED AND INTERCONNECTED SMOKE AND CO DETECTORS WITH BATTERY BACKUP PER CODE REQUIREMENTS & AS DIRECTED BY THE LOCAL BUILDING DEPT.

    6.PROTECT IN PLACE ALL EXISTING FIXTURES AND SURFACES SCHEDULED TO REMAIN.

    7.PATCH AND REPAIR EXISTING WALLS LOCATED IN UNALTERED AREAS AFFECTED BY ALL NEW WORK, WHETHER SHOWN ON THE DRAWINGS OR NOT.

    8.PATCH, PAINT AND REFINISH ALL EXISTING WALLS, FLOORS, CEILINGS & TRIM THROUGHOUT REPLACE MATERIALS IN-KIND WHEN DAMAGED PAST POINT OF REPAIR.

    9.PLANS DO NOT FULLY REPRESENT ALL NEW WORK. THE CONSTRUCTION DOCUMENTS ARE INTENDED TO TO SERVE AS GENERAL GUIDELINES.

    10.DIMENSIONS SHOWN ARE FROM FACE OF STUD OR FACE OF EXISTING CONSTRUCTION UNLESS NOTED OTHERWISE.

    GENERAL NOTES 11.PROVIDE ELECTRICAL PER STATE ELECTRICAL CODE REQUIREMENTS. PROVIDE POWER FOR ALL APPLIANCES. LOCATE NEW ELECTRICAL DEVICES PER NEC REQUIREMENTS & OWNER'S REQUIREMENTS.

    12.PROVIDE PLUMBING PER STATE PLUMBING CODE REQUIREMENTS

    13.HVAC SYSTEM TO BE DESIGN BUILD, PROVIDE PER STATE CODE REQUIREMENTS.

    14.PROVIDE SOLID WOOD BLOCKING AS REQUIRED.

    15.PROVIDE FIRE EXTINGUISHERS PER CODE AND PER REQUIREMENTS OF THE BUILDING OFFICIAL.

    16.INSTALL BATT INSULATION FULL DEPTH AT ALL EXPOSED STUD CAVITIES (CLOSED CELL SPRAY FOAM AT ATTIC ROOF CAVITIES)

    17.COVER ALL WALLS AND CEILINGS W/1/2" THICK GYPSUM BOARD UNLESS NOTED OTHERWISE.

    18.PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM BOARD AT BATHROOMS UNLESS NOTED OTHERWISE.

    19.ALL APPLIANCES PROVIDED BY OWNER, INSTALLED BY CONTRACTOR.

    20.RECONNECT EXISTING FIXTURES TO NEW SWITCH LOCATIONS AS REQUIRED IN THE FIELD.

    21.PROVIDE DIMMERS AS DIRECTED BY OWNER

    22.A/V, CATV, TELEPHONE AND OTHER LOW VOLTAGE WIRING NOT SHOWN. SYSTEM TO BE DESIGN/BUILD. CONTACT OWNER FOR LOCATIONS OF ALL LOW VOLTAGE WIRING.

    PLAN LEGEND

    A5.12

    A5.1 1

    1 3 4 5

    21' - 10" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 21' - 10"

    2 6 7 8 9

    140 SFBR

    161 SFBR

    393 SFL/D/K

    W/D

    16 SFCLO

    11 SFCLO

    9 SFCLO39 SF

    BATH

    140 SFBR

    161 SFBR

    392 SFL/D/K

    W/D

    16 SFCLO

    11 SFCLO

    9 SFCLO

    39 SFBATH

    41 SFBATH

    124 SFBR

    261 SFL/D/K

    9 SFCLO

    8 SFCLO

    146 SFBR 226 SF

    L/D/K275 SFL/D/K

    129 SFBR 140 SF

    BR

    32 SFTRASH

    53 SFELEV.

    D

    C

    B

    A

    140 SFBR

    169 SFBR

    386 SFL/D/K16 SF

    CLO

    9 SFCLO39 SF

    BATH

    140 SFBR

    161 SFBR

    393 SFL/D/K

    W/D

    16 SFCLO

    11 SFCLO

    9 SFCLO

    39 SFBATH

    41 SFBATH

    117 SFBR

    149 SFBR

    300 SFL/D/K

    41 SFBATH

    W/D

    16 SFCLO

    36 SFCLO

    41 SFBATH

    12 SFCLO

    134 SFBR

    W/D

    244 SFL/D/K

    10 SFCLO

    6 SFCLO

    147 SFBR251 SF

    L/D/K319 SFL/D/K

    9 SFCLO

    129 SFBR140 SF

    BR

    36 SFCLO

    53 SFELEV. 134 SF

    JANITOR

    93' - 10" 93' - 10"

    187' - 8"

    W/D

    62 SFBATH

    149 SFBR

    280 SFL/D/K

    36 SFCLO

    41 SFBATH

    125 SFBR

    9 SFCLO

    8 SFCLO

    W/D

    62 SFBATH

    40 SFBATH

    W/D

    11 SFCLO

    40 SFBATH

    W/D

    9 SFCLO

    12 SFCLO

    40 SFBATH

    36 SFCLO

    11 SFCLO

    40 SFBATH

    W/D

    11 SFCLOW/D

    40 SFBATH

    12 SFCLO

    40 SFBATH W/D

    A5.2

    1

    149 SFSTAIR 3

    149 SFSTAIR 2

    149 SFSTAIR 1

    1280 SFHALL

    PR

    OJE

    CT

    NU

    MB

    ER

    :

    DA

    VID

    SIS

    SO

    N A

    RC

    HIT

    EC

    TUR

    E P

    C --

    - ALL

    RIG

    HTS

    RE

    SE

    RV

    ED

    d a

    v i d

    s i

    s s

    o n

    a r

    c h

    i t e

    c t

    u r e

    pc

    238

    Fifth

    Stre

    etP

    rovi

    denc

    e R

    I 029

    06w

    ww

    .ds-

    arch

    .com

    401

    -595

    -707

    0

    A B C D

    1

    2

    3

    4

    SCHE

    MATIC

    DESIG

    N ONL

    Y

    NOT F

    OR

    CONS

    TRUC

    TION

    A4.2

    PLAN

    S-

    L2T O

    L 5

    1611

    2

    9H

    e ma n

    sW

    orce

    ster

    , MA

    0160

    5

    1/8" = 1'-0"A4FLOOR PLAN - L2

    DAT

    E:IS

    S UED

    FOR:

    2017

    -05-

    23S

    CH

    EMAT

    ICD

    ESIG

    N

  • DNDNDN

    WD1W1

    CT1

    101ROOM NAME

    ROOM FINISH KEY

    CONTRACT LIMIT LINE

    EXISTING DOOR

    NEW DOOR

    PARTITIONS, DOORS AND ITEMS TO BE REMOVED

    FULL HEIGHT PARTITION

    PARTIAL HEIGHT PARTITION

    DIMENSION TO THE FACE OF FRAMING OR MASONRY AT NEW CONSTRUCTION, TYP.DIMENSION TO THE FACE OF FINISH AT EXISTING CONSTRUCTION

    DIMENSION TO THE FACE OF FINISH

    EXISTING PARTITION

    1.VERIFY ALL DIMENSIONS IN THE FIELD. DO NOT SCALE DRAWINGS.

    2.ALL INTERIOR WALLS 2X4 AT 16" O.C. UNLESS NOTED OTHERWISE. PROVIDE DOUBLE TOP PLATES. SEE B4/A0.0

    3.ALL DOOR JAMBS 4" OFF WALL UNLESS NOTED OTHERWISE

    4.CENTER DOORS IN WALL UNLESS NOTED OTHERWISE

    5.PROVIDE HARDWIRED AND INTERCONNECTED SMOKE AND CO DETECTORS WITH BATTERY BACKUP PER CODE REQUIREMENTS & AS DIRECTED BY THE LOCAL BUILDING DEPT.

    6.PROTECT IN PLACE ALL EXISTING FIXTURES AND SURFACES SCHEDULED TO REMAIN.

    7.PATCH AND REPAIR EXISTING WALLS LOCATED IN UNALTERED AREAS AFFECTED BY ALL NEW WORK, WHETHER SHOWN ON THE DRAWINGS OR NOT.

    8.PATCH, PAINT AND REFINISH ALL EXISTING WALLS, FLOORS, CEILINGS & TRIM THROUGHOUT REPLACE MATERIALS IN-KIND WHEN DAMAGED PAST POINT OF REPAIR.

    9.PLANS DO NOT FULLY REPRESENT ALL NEW WORK. THE CONSTRUCTION DOCUMENTS ARE INTENDED TO TO SERVE AS GENERAL GUIDELINES.

    10.DIMENSIONS SHOWN ARE FROM FACE OF STUD OR FACE OF EXISTING CONSTRUCTION UNLESS NOTED OTHERWISE.

    GENERAL NOTES 11.PROVIDE ELECTRICAL PER STATE ELECTRICAL CODE REQUIREMENTS. PROVIDE POWER FOR ALL APPLIANCES. LOCATE NEW ELECTRICAL DEVICES PER NEC REQUIREMENTS & OWNER'S REQUIREMENTS.

    12.PROVIDE PLUMBING PER STATE PLUMBING CODE REQUIREMENTS

    13.HVAC SYSTEM TO BE DESIGN BUILD, PROVIDE PER STATE CODE REQUIREMENTS.

    14.PROVIDE SOLID WOOD BLOCKING AS REQUIRED.

    15.PROVIDE FIRE EXTINGUISHERS PER CODE AND PER REQUIREMENTS OF THE BUILDING OFFICIAL.

    16.INSTALL BATT INSULATION FULL DEPTH AT ALL EXPOSED STUD CAVITIES (CLOSED CELL SPRAY FOAM AT ATTIC ROOF CAVITIES)

    17.COVER ALL WALLS AND CEILINGS W/1/2" THICK GYPSUM BOARD UNLESS NOTED OTHERWISE.

    18.PROVIDE MOISTURE AND MOLD RESISTANT GYPSUM BOARD AT BATHROOMS UNLESS NOTED OTHERWISE.

    19.ALL APPLIANCES PROVIDED BY OWNER, INSTALLED BY CONTRACTOR.

    20.RECONNECT EXISTING FIXTURES TO NEW SWITCH LOCATIONS AS REQUIRED IN THE FIELD.

    21.PROVIDE DIMMERS AS DIRECTED BY OWNER

    22.A/V, CATV, TELEPHONE AND OTHER LOW VOLTAGE WIRING NOT SHOWN. SYSTEM TO BE DESIGN/BUILD. CONTACT OWNER FOR LOCATIONS OF ALL LOW VOLTAGE WIRING.

    PLAN LEGEND

    A5.12

    A5.0

    A5.1 1

    A4

    1 3 4 52 6 7 8 9

    D

    C

    B

    A

    A5.2

    1

    140 SFBR

    161 SFBR

    393 SFL/D/K 16 SF

    CLO

    11 SFCLO

    9 SFCLO39 SF

    BATH

    140 SFBR

    161 SFBR

    392 SFL/D/K

    16 SFCLO

    11 SFCLO

    9 SFCLO

    39 SFBATH

    41 SFBATH

    124 SFBR

    260 SFL/D/K

    9 SFCLO

    8 SFCLO

    147 SFBR 251 SF

    L/D/K318 SFL/D/K

    129 SFBR 140 SF

    BR

    319 SFL/D/K

    9 SFCLO

    123 SFBR140 SF

    BR

    36 SFCLO

    155 SFJANITOR

    62 SFBATH

    149 SFBR

    280 SFL/D/K

    36 SFCLO

    41 SFBATH

    125 SFBR

    9 SFCLO

    8 SFCLO

    62 SFBATH

    40 SFBATH

    11 SFCLO

    40 SFBATH

    9 SFCLO

    12 SFCLO

    40 SFBATH

    36 SFCLO 40 SF

    BATH

    11 SFCLO

    311 SFL/D/K

    8 SFCLO

    116 SFBR

    118 SFBR

    36 SFCLO

    29 SFBATH

    11 SFCLO

    149 SFSTAIR 3

    1202 SFHALL

    32 SFTRASH

    53 SFELEV 1

    53 SFELEV 2

    149 SFSTAIR 2

    149 SFSTAIR 1

    PR

    OJE

    CT

    NU

    MB

    ER

    :

    DA

    VID

    SIS

    SO

    N A

    RC

    HIT

    EC

    TUR

    E P

    C --

    - ALL

    RIG

    HTS

    RE

    SE

    RV

    ED

    d a

    v i d

    s i

    s s

    o n

    a r

    c h

    i t e

    c t

    u r e

    pc

    238

    Fifth

    Stre

    etP

    rovi

    denc

    e R

    I 029

    06w

    ww

    .ds-

    arch

    .com

    401

    -595

    -707

    0

    A B C D

    1

    2

    3

    4

    SCHE

    MATIC

    DESIG

    N ONL

    Y

    NOT F

    OR

    CONS

    TRUC

    TION

    A4.3

    PLAN

    S-L

    6

    1611

    2

    9H

    e ma n

    sW

    orce

    ster

    , MA

    0160

    5

    KEYED NOTES

    1/8" = 1'-0"A4FLOOR PLAN - L6

    DAT

    E:IS

    S UED

    FOR:

    2017

    -05-

    23S

    CH

    EMAT

    ICD

    ESIG

    N

  • L0604' - 0"

    L1620' - 0"

    L2630' - 4"

    L3639' - 8"

    L4649' - 0"

    L5658' - 4"

    L6667' - 8"

    TOP PLATE677' - 0"

    GRADEPLANE-LOWER

    606' - 11"

    ROOF685' - 10"

    TOP FOUND 1610' - 8"

    PER

    BU

    ILD

    ING

    CO

    DE

    75' -

    9" H

    EIG

    HT

    WO

    OD

    FR

    AM

    ED

    -3B

    STE

    EL/

    CO

    NC

    - 1A

    9' -

    4"9'

    - 4"

    9' -

    4"9'

    - 4"

    9' -

    4"10

    ' - 4

    "16

    ' - 0

    "

    3"

    1'-0"

    PR

    OJE

    CT

    NU

    MB

    ER

    :

    DA

    VID

    SIS

    SO

    N A

    RC

    HIT

    EC

    TUR

    E P

    C --

    - ALL

    RIG

    HTS

    RE

    SE

    RV

    ED

    d a

    v i d

    s i

    s s

    o n

    a r

    c h

    i t e

    c t

    u r e

    pc

    238

    Fifth

    Stre

    etP

    rovi

    denc

    e R

    I 029

    06w

    ww

    .ds-

    arch

    .com

    401

    -595

    -707

    0

    A B C D

    1

    2

    3

    4

    SCHE

    MATIC

    DESIG

    N ONL

    Y

    NOT F

    OR

    CONS

    TRUC

    TION

    A5.0

    ELEV

    ATIO

    NS

    1611

    2

    9H

    e ma n

    sW

    orce

    ster

    , MA

    0160

    5

    KEYED NOTES

    1/8" = 1'-0"A4WEST ELEVATION

    DAT

    E:IS

    S UED

    FOR:

    2017

    -05-

    23S

    CH

    EMAT

    ICD

    ESIG

    N

  • L0604' - 0"

    L1620' - 0"

    L2630' - 4"

    L3639' - 8"

    L4649' - 0"

    L5658' - 4"

    L6667' - 8"

    TOP PLATE677' - 0"

    GRADEPLANE-LOWER

    606' - 11"

    ROOF685' - 10"

    TOP FOUND 1610' - 8"

    16' -

    0"

    10' -

    4"

    9' -

    4"9'

    - 4"

    9' -

    4"9'

    - 4"

    9' -

    4"

    PER

    BUIL

    DI N

    GC

    OD

    E

    75'-

    0"H

    EIG

    HT

    WO

    OD

    FR

    AM

    ED

    -3B

    STE

    EL/

    CO

    NC

    - 1A

    3"

    1'-0"

    L0604' - 0"

    L1620' - 0"

    L2630' - 4"

    L3639' - 8"

    L4649' - 0"

    L5658' - 4"

    L6667' - 8"

    TOP PLATE677' - 0"

    GRADEPLANE-LOWER

    606' - 11"

    ROOF685' - 10"

    TOP FOUND 1610' - 8"

    16'-

    0"10

    '-4"

    9'-4

    "9'

    -4"

    9'-4

    "9'

    -4"

    9'-4

    "

    PER

    BUIL

    DI N

    GC

    OD

    E

    75'-

    0"H

    EIG

    HT

    WO

    OD

    FR

    AM

    ED

    -3B

    STE

    EL/

    CO

    NC

    - 1A

    3"

    1'-0"

    PR

    OJE

    CT

    NU

    MB

    ER

    :

    DA

    VID

    SIS

    SO

    N A

    RC

    HIT

    EC

    TUR

    E P

    C --

    - ALL

    RIG

    HTS

    RE

    SE

    RV

    ED

    d a

    v i d

    s i

    s s

    o n

    a r

    c h

    i t e

    c t

    u r e

    pc

    238

    Fifth

    Stre

    etP

    rovi

    denc

    e R

    I 029

    06w

    ww

    .ds-

    arch

    .com

    401

    -595

    -707

    0

    A B C D

    1

    2

    3

    4

    SCHE

    MATIC

    DESIG

    N ONL

    Y

    NOT F

    OR

    CONS

    TRUC

    TION

    A5.1

    ELEV

    ATIO

    NS

    1611

    2

    9H

    e ma n

    sW

    orce

    ster

    , MA

    0160

    5

    KEYED NOTES

    1/8" = 1'-0"1NORTH ELEVATION

    1/8" = 1'-0"2SOUTH ELEVATION

    DAT

    E:IS

    S UED

    FOR:

    2017

    -05-

    23S

    CH

    EMAT

    ICD

    ESIG

    N

  • L0604' - 0"

    L1620' - 0"

    L2630' - 4"

    L3639' - 8"

    L4649' - 0"

    L5658' - 4"

    L6667' - 8"

    TOP PLATE677' - 0"

    GRADEPLANE-LOWER

    606' - 11"

    ROOF685' - 10"

    TOP FOUND 1610' - 8"

    PER

    BU

    ILD

    ING

    CO

    DE

    75' -

    9" H

    EIG

    HT

    WO

    OD

    FR

    AM

    ED

    -3B

    STE

    EL/

    CO

    NC

    - 1A

    9' -

    4"9'

    - 4"

    9' -

    4"9'

    - 4"

    9' -

    4"10

    ' - 4

    "16

    ' - 0

    "

    3"

    1'-0"

    PR

    OJE

    CT

    NU

    MB

    ER

    :

    DA

    VID

    SIS

    SO

    N A

    RC

    HIT

    EC

    TUR

    E P

    C --

    - ALL

    RIG

    HTS

    RE

    SE

    RV

    ED

    d a

    v i d

    s i

    s s

    o n

    a r

    c h

    i t e

    c t

    u r e

    pc

    238

    Fifth

    Stre

    etP

    rovi

    denc

    e R

    I 029

    06w

    ww

    .ds-

    arch

    .com

    401

    -595

    -707

    0

    A B C D

    1

    2

    3

    4

    SCHE

    MATIC

    DESIG

    N ONL

    Y

    NOT F

    OR

    CONS

    TRUC

    TION

    A5.2

    ELEV

    ATIO

    NS

    1611

    2

    9H

    e ma n

    sW

    orce

    ster

    , MA

    0160

    5

    1/8" = 1'-0"1EAST ELEVATION

    DAT

    E:IS

    S UED

    FOR:

    2017

    -05-

    23S

    CH

    EMAT

    ICD

    ESIG

    N

    16112 9 Hemans - OPT 6 - Sheet - A4-0 - BASEMENT (L0) PLANSheetsA4.0 - BASEMENT (L0) PLANA4.1 - PLANS - L1A4.2 - PLANS - L2 TO L5A4.3 - PLANS - L6A5.0 - ELEVATIONSA5.1 - ELEVATIONSA5.2 - ELEVATIONS

    16112 9 Hemans - OPT 6 - Sheet - A4-1 - PLANS - L1SheetsA4.0 - BASEMENT (L0) PLANA4.1 - PLANS - L1A4.2 - PLANS - L2 TO L5A4.3 - PLANS - L6A5.0 - ELEVATIONSA5.1 - ELEVATIONSA5.2 - ELEVATIONS

    16112 9 Hemans - OPT 6 - Sheet - A4-2 - PLANS - L2 TO L5SheetsA4.0 - BASEMENT (L0) PLANA4.1 - PLANS - L1A4.2 - PLANS - L2 TO L5A4.3 - PLANS - L6A5.0 - ELEVATIONSA5.1 - ELEVATIONSA5.2 - ELEVATIONS

    16112 9 Hemans - OPT 6 - Sheet - A4-3 - PLANS - L6SheetsA4.0 - BASEMENT (L0) PLANA4.1 - PLANS - L1A4.2 - PLANS - L2 TO L5A4.3 - PLANS - L6A5.0 - ELEVATIONSA5.1 - ELEVATIONSA5.2 - ELEVATIONS

    16112 9 Hemans - OPT 6 - Sheet - A5-0 - ELEVATIONSSheetsA4.0 - BASEMENT (L0) PLANA4.1 - PLANS - L1A4.2 - PLANS - L2 TO L5A4.3 - PLANS - L6A5.0 - ELEVATIONSA5.1 - ELEVATIONSA5.2 - ELEVATIONS

    16112 9 Hemans - OPT 6 - Sheet - A5-1 - ELEVATIONSSheetsA4.0 - BASEMENT (L0) PLANA4.1 - PLANS - L1A4.2 - PLANS - L2 TO L5A4.3 - PLANS - L6A5.0 - ELEVATIONSA5.1 - ELEVATIONSA5.2 - ELEVATIONS

    16112 9 Hemans - OPT 6 - Sheet - A5-2 - ELEVATIONSSheetsA4.0 - BASEMENT (L0) PLANA4.1 - PLANS - L1A4.2 - PLANS - L2 TO L5A4.3 - PLANS - L6A5.0 - ELEVATIONSA5.1 - ELEVATIONSA5.2 - ELEVATIONS