spots 10.0 performance reports

269
E200301-01-214-V10.0I-01 SIEMENS S.A. SPOTS V10 Drop 4 Siemens Performance Reports July/2003

Upload: urshadow

Post on 17-Jun-2015

146 views

Category:

Education


1 download

DESCRIPTION

Spots 10.0 Performance Reports

TRANSCRIPT

Page 1: Spots 10.0 Performance Reports

E200301-01-214-V10.0I-01

SIEMENS S.A.

SPOTS V10 Drop 4

Siemens Performance Reports

July/2003

Page 2: Spots 10.0 Performance Reports

SIEMENS S.A.OG IC R&D WON NM CP2

R. Irmãos Siemens, nº 12720-093 AmadoraPortugal

All rights reserved. No part of this document may be reproduced or transmitted inany form or by any means, electronic or mechanical, including photocopying andrecording, for any purpose other than the purchaser’s personal use without thewritten permission of Siemens S.A.This document consists of a total of 269 pages.The information contained in this document is subject to change.

Page 3: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 3

Table of Contents

1 INTRODUCTION ........................................................................................................................................61.1 Purpose ........................................................................................................................................................ 61.2 Reference Documents.................................................................................................................................. 71.3 Abbreviations................................................................................................................................................ 81.4 Definitions..................................................................................................................................................... 9

2 PU LOAD ..............................................................................................................................................132.1 Core Network.............................................................................................................................................. 13

2.1.1 MP Load Report................................................................................................................................. 142.1.2 CP Load Report ................................................................................................................................. 16

2.2 Radio Access Network ............................................................................................................................... 182.2.1 BSC Load Report............................................................................................................................... 192.2.2 NodeB Load Report ........................................................................................................................... 212.2.3 RNC Processor Load Report ............................................................................................................. 23

SS7 SURVEILLANCE ................................................................................................................................253.1 CCNC Platforms ......................................................................................................................................... 25

3.1.1 CCNC SS7 Switch Surveillance Report ............................................................................................. 263.1.2 CCNC SS7 Route Set Surveillance Report........................................................................................ 283.1.3 CCNC SS7 Link Set Surveillance Report........................................................................................... 293.1.4 CCNC SS7 Link Surveillance Report ................................................................................................. 303.1.5 CCNC SS7 Link Load Report ............................................................................................................ 31

3.2 SSNC Platforms ......................................................................................................................................... 333.2.1 SSNC SS7 Node Surveillance Report ............................................................................................... 343.2.2 SSNC SS7 Sign Point Surveillance Report........................................................................................ 353.2.3 SSNC SS7 Route Set Surveillance Report ........................................................................................ 363.2.4 SSNC SS7 Link Set Surveillance Report ........................................................................................... 373.2.5 SSNC SS7 Link Surveillance Report ................................................................................................. 39

4 CORE NETWORK....................................................................................................................................414.1 CS .............................................................................................................................................................. 41

4.1.1 TGRP Load Report ............................................................................................................................ 424.1.2 TGRP Load Type Report ................................................................................................................... 474.1.3 Dest Report........................................................................................................................................ 494.1.4 Flow Report ....................................................................................................................................... 524.1.5 PBX Load Report ............................................................................................................................... 554.1.6 PBX Service Load Report .................................................................................................................. 574.1.7 MSC VLR Surveillance ...................................................................................................................... 59

4.1.7.1 MSC Grade of Service Report................................................................................................... 594.1.7.2 VLR Load Analysis Report ........................................................................................................ 634.1.7.3 Mobile Originating Calls Analysis Report .................................................................................. 65

4.1.7.3.1 UMTS Mobile Originating Calls Analysis Report............................................................... 684.1.7.4 Mobile Terminating Calls Analysis Report................................................................................. 71

4.1.7.4.1 UMTS Mobile Terminating Calls Analysis Report ............................................................. 744.1.7.5 Handover Analysis Report......................................................................................................... 76

4.1.7.5.1 UMTS Handover Analysis Report ..................................................................................... 784.1.7.6 Location Update Analysis Report .............................................................................................. 804.1.7.7 Short Message Service Analysis Report ................................................................................... 824.1.7.8 Data And Fax Analysis Report .................................................................................................. 844.1.7.9 MSC Call Flow Report............................................................................................................... 884.1.7.10 MSC Handover Flow Report ................................................................................................... 90

4.2 PS............................................................................................................................................................... 914.2.1 ATM SP on xGSN .............................................................................................................................. 92

4.2.1.1 GTP Throughput Report............................................................................................................ 924.2.2 GGSN ................................................................................................................................................ 94

4.2.2.1 Virtual Router Load Report........................................................................................................ 944.2.2.2 ISP Session Analysis Report..................................................................................................... 96

4.2.3 ATM MP on SGSN............................................................................................................................. 984.2.3.1 MP Overload ............................................................................................................................. 98

4.2.3.1.1 SGSN Uplink MP Overload Report ................................................................................... 984.2.3.1.2 SGSN Downlink MP Overload Report ............................................................................ 101

Page 4: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

4 E200301-01-214-V10.0I-01

4.2.3.2 SGSN Licence Violations Report ............................................................................................ 1034.2.3.3 Reports with 2nd and 3rd Generation variants .......................................................................... 105

4.2.3.3.1 SGSN Session Analysis Report...................................................................................... 1054.2.3.3.2 SGSN Performance Analysis Report .............................................................................. 1084.2.3.3.3 SGSN Nominal Load Report........................................................................................... 111

4.2.3.4 Cisco based GGSN Reports ................................................................................................... 1144.2.3.4.1 APN Performance Report ............................................................................................... 1144.2.3.4.2 GGSN Performance Report............................................................................................ 1144.2.3.4.3 GTP Throughput Report ................................................................................................. 115

4.3 VAS .......................................................................................................................................................... 1164.3.1 MSP ................................................................................................................................................. 117

5 RADIO ACCESS NETWORK....................................................................................................................1185.1 GERAN..................................................................................................................................................... 118

5.1.1 Base Station Overview Report ......................................................................................................... 1195.1.2 Base Station Ranking Report........................................................................................................... 1245.1.3 Base Station Grade Of Service Report ............................................................................................ 1275.1.4 Base Station Call Setup Analysis Report ......................................................................................... 1335.1.5 Base Station Traffic Flow Report ..................................................................................................... 1355.1.6 Base Station Traffic Report.............................................................................................................. 1375.1.7 Base Station Synthesis Report ........................................................................................................ 1405.1.8 Base Station Handover Overview Report ........................................................................................ 1445.1.9 Base Station Handover Analysis Report .......................................................................................... 1475.1.10 Base Station Outgoing Handover Report....................................................................................... 1505.1.11 Unbalanced Links Report............................................................................................................... 1535.1.12 Base Station GPRS Performance Report ...................................................................................... 1555.1.13 Base Station Interference Band Report ......................................................................................... 1575.1.14 TRX Level And Quality Report ....................................................................................................... 1585.1.15 Base Station Link Quality Report ................................................................................................... 1605.1.16 Correlated Data Histogram Reports............................................................................................... 163

5.2 UTRAN ..................................................................................................................................................... 1655.2.1 UTRAN Overview Report ................................................................................................................. 1665.2.2 Connection Drop per Cause Report................................................................................................. 1695.2.3 RRC Analysis Report ....................................................................................................................... 1715.2.4 RRC Establishment per Cause Report ............................................................................................ 1745.2.5 RAB Analysis Report ....................................................................................................................... 1765.2.6 RAB Failure per Cause Report ........................................................................................................ 1795.2.7 Soft HO Analysis Report .................................................................................................................. 1815.2.8 Branch Addition Failure per Cause Report ...................................................................................... 1845.2.9 Hard HO Analysis Report................................................................................................................. 186

6 REAL-TIME REPORTS...........................................................................................................................1896.1 Bar-Chart Reports Visualization ............................................................................................................... 1906.2 Monitoring Panel Reports Visualization .................................................................................................... 1916.3 CN Circuit Switched Real-Time Reports................................................................................................... 192

6.3.1 MSC Monitoring Panel Report ......................................................................................................... 1936.3.2 EXCH Bar Chart Report................................................................................................................... 1956.3.3 LOCAR Bar Chart Report ................................................................................................................ 2046.3.4 CELL Bar Chart Report.................................................................................................................... 2056.3.5 ANGRP Bar Chart Report ................................................................................................................ 206

6.4 CN Packet Switched Real-Time Reports.................................................................................................. 2076.4.1 BIAS Load Monitoring Panel Report ................................................................................................ 2086.4.2 APN Bar Chart Report ..................................................................................................................... 2106.4.3 CARD Bar Chart Report................................................................................................................... 2116.4.4 VRINDEX Bar Chart Report............................................................................................................. 2146.4.5 SLOTPORT Bar Chart Report ......................................................................................................... 2166.4.6 DLC Bar Chart Report...................................................................................................................... 2196.4.7 VPL Bar Chart Report ...................................................................................................................... 2206.4.8 VCL Bar Chart Report...................................................................................................................... 2216.4.9 MIB2IFINDEX Bar Chart Report ...................................................................................................... 2226.4.10 VR Bar Chart Report...................................................................................................................... 2246.4.11 RADIUSACC Bar Chart Report...................................................................................................... 2266.4.12 RADIUSAUTH Bar Chart Report.................................................................................................... 2286.4.13 BVC Bar Chart Report ................................................................................................................... 2316.4.14 NSE Bar Chart Report ................................................................................................................... 2326.4.15 NSVC Bar Chart Report................................................................................................................. 2336.4.16 CAPN Bar Chart Report................................................................................................................. 2346.4.17 CMIB2IFINDEX Bar Chart Report.................................................................................................. 235

Page 5: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 5

6.4.18 CGGSN Bar Chart Report.............................................................................................................. 2376.5 VAS Real-Time Reports ........................................................................................................................... 239

6.5.1 MSP Bar Chart Report ..................................................................................................................... 2406.6 GERAN Real-Time Reports...................................................................................................................... 242

6.6.1 BTS Monitoring Panel Report .......................................................................................................... 2436.6.2 BTS Bar Chart Report...................................................................................................................... 2456.6.3 TRX Bar Chart Report...................................................................................................................... 2536.6.4 BSC Bar Chart Report ..................................................................................................................... 2546.6.5 BTSM Bar Chart Report................................................................................................................... 255

6.7 UTRAN Real-Time Reports ...................................................................................................................... 2566.7.1 UCELL Monitoring Panel Report...................................................................................................... 2576.7.2 RNC Monitoring Panel Report ......................................................................................................... 2596.7.3 UCELL Bar Chart Report ................................................................................................................. 2616.7.4 RNC Bar Chart Report ..................................................................................................................... 2656.7.5 STM1LINE Bar Chart Report ........................................................................................................... 2676.7.6 E1LINE Bar Chart Report ................................................................................................................ 2686.7.7 STM1VP Bar Chart Report .............................................................................................................. 269

Page 6: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

6 E200301-01-214-V10.0I-01

1 Introduction

1.1 Purpose

The goal of this document is to provide the detailed description of all SPOTS V10.0 Performance Pre-Defined Reports.

The usage of a separate document to describe SIEMENS reports takes into account the fact thatthese reports may evolve faster than the SPOTS infrastructure itself; thus, this solution provides asuitable response to changing customer requirements.

A very large set of pre-defined performance measurement reports covering all technological domains,are provided under the "SIEMENS reports" folder. These are the SIEMENS suggested pre-definedreports, which were developed making use of a large experience supporting network operators all overthe world. They should be considered just as SIEMENS proposals that neither cover every specificaspect of each network nor are thought to be compliant with every operator usual workflow.

Case it is found necessary to extend the functionality of these reports (e.g. customisation for aparticular case), SIEMENS reports can be used as templates to build custom reports. This can bedone using the Reports Editor interface, described within [21], to edit the reports according to thesyntax of the SPOTS reporting language (SRL). The syntax of this language is very simple, butpowerful enough to describe any complex report — for details about SRL please refer to [18].Be aware that, if changes are performed over the original version of the report (i.e. keeping the samereport name), they will be lost upon upgrade to a new SPOTS installation. To avoid this, copy thereport to a different file name after editing it — through this process, any number of versions of a pre-defined report can be created.

Figure 1 – Reports Editor Interface.

Page 7: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 7

1.2 Reference Documents

[01] Training Documentation 1835 : SSS Traffic Measurement

[02] 3GPP TS 52.402 Telecommunication ManagementPerformance Management (PM) – Performance Measurements – GSM

[03] Information – Traffic Data Administration – Traffic Measurement(Siemens Doc A50016-D1108-G801-*-7618)

[04] Information – Traffic Data Administration – Traffic Measurement(Siemens Doc A50016-D1109-G801-*-7618)

[05] Service InformationTraffic Administration and Monitoring the Grade of Service (GOS)

[06] Information – Performance Management(Siemens Doc A50016-D3102-G803-*-7618)

[07] Information – Traffic and Performance Data Counter Description (CS)(Siemens Doc A50016-D1702-G802-*-7618)

[08] Information – System – Performance Management(Siemens Doc A50016-D3102-G803-*-7618)

[09] Information – Traffic and Performance Data Counter Description (PS)(Siemens Doc A50016-D1702-G803-*-7618)

[10] Performance Management (GR3.0/UCR2.0)(Siemens Doc P30308-A9001-A133-*-7659)

[11] Information – Traffic – Traffic Measurement(Siemens Doc A30828-X1133-G410-*-7618)

[12] Information – Traffic – Traffic Measurement(Siemens Doc A30828-X1150-G410-*-7618)

[13] Information – Performance Measurement Counter(Siemens Doc A30308-X3247-G040-*-7618)

[14] Information – PM:SBS Counter(Siemens Doc A30308-X3247-H40-*-7618)

[15] Information – PM:SBS Counter(Siemens Doc A30808-X3247-K40-*-7618)

[16] Performance Measurement SBS Message Flows(Siemens Doc A30808-X3247-G41-2-7618)

[17] UTRAN – Performance Measurement ProcedureUMTS Terrestrial Radio Access Network – TED:PMC(Siemens Doc A50016-G5000-C202-*-7618)

[18] Reports Processing Language – SPOTS V10(SSA Doc E200109-01-314-V10.0I-*)

[19] Information – PM:SBS Key Performance Indicators(Siemens Doc A30808-X3247-A912-*-7618)

[20] UTRAN Key Performance Indicators(MOBNET doc released IUS at 2002-08-02)

[21] User Manual – SPOTS V10(SSA Doc E200301-01-114-V10.0I-*)

[22] Data Model – SPOTS V10(SSA Doc E200301-01-414-V10.0I-*)

Page 8: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

8 E200301-01-214-V10.0I-01

1.3 Abbreviations

BSC Base Station Controller.BR BSS Release.BSS Base Station System.BTS Base Transceiver Station.CCNC Common Channel Network Control.CP Coordination Processor.CS Circuit Switching.EDGE Enhanced Data rates for GSM Evolution.GERAN GSM and EDGE Radio Access Network (formerly known as BSS).GGSN Gateway GPRS Support Node.GOS Grade Of Service.GPRS General Packet Radio Service.GSM Global System For Mobile Communications.GSS GPRS Sub-System.GR GSS Release.HO Handover.I-RAT Inter-Radio Access Technology.IP Internet Protocol.ISP Internet Service Provider.MP Main Processor; designation of NE platform ("36190") that uses this processor.MSC Mobile Switching Centre.NE Network Element (also referred to as "node" or "network node").PBH Peak Busy Hour.PDCH Packet Data Channel.PM Performance Management.PO Packet-Oriented.PS Packet Switching.QoS Quality of Service.RNC Radio Network Controller.SBS Siemens BSS.SGSN Serving GPRS Support Node.SPBH Sample at PBH.SP Service Processor; designation of NE platform ("XP140") that uses this processor.SPOTS Support for Planning, Operation & Maintenance and Traffic Analysis.SRL SPOTS Reporting Language.SS7 Signalling System No. 7SSNC Signalling System Network Control.TRX Transceiver.UMTS Universal Mobile Telecommunication System.UTRAN UMTS Terrestrial Radio Access Network.

Page 9: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 9

1.4 Definitions

In this chapter several terms frequently used within this document are defined. Please be aware thatsome definitions represent a restriction to the normal use of the term that only applies to the presentdocument.

Abbreviated NameThe performance indicator abbreviated name that will be displayed on the report output. For the KPIsdescribed within [17] and [19], a short KPI name is usually defined and often used as abbreviatedname.

AggregationThe Aggregation field will show how to evaluate for multiple elementary time periods (also calledsample periods or granularity periods). Below are the aggregation criteria:

SPBH TC Peak Sample at Time Coherent Peak Busy Hour for one or more days.The Time Coherent Peak Busy Hour is calculated by evaluating theDetailed data for a group of days, finding the day-profile (i.e. evolution of areference variable throughout the time for one day) corresponding to theaverage day, and finally, obtaining the PBH from that day profile.

SPBH Avg Peak Average of the Sample at Peak Busy Hour for one or more days.

SPBH Max Peak Sample at the Maximum of the Peak Busy Hours for one or more days.

Total Total value for one or more days.

Total DTL Total value for one or more days calculated based on the Detailed data forthose days. The Detailed data corresponds PM raw data.

Total SPBH Total value for one or more days referring only to the Peak Busy Hourresults. Obtained by adding the results of consecutive samples at PeakBusy Hour.

SPBH Daily Peaks Sample at Peak Busy Hour for each day.

DTOT Total value for each day.

TEVL Regular samples providing a time evolution. The granularity of thesamples is defined within the Reports code and is based on the databaseDetailed data.

Auxiliary HeaderSome Performance Indicators can be grouped in the report under certain common information toenable a user-friendly layout. The auxiliary header will give a hint about the performance indicatorsmeaning and can also provide information about the use-case to which is mainly addressed.

Counter NameThe performance measurement counter names according to Siemens counter specificationdocuments: [03], [04], [07], [09], [13], [14], [15] and [17].Different counters can share the same name if provided within different measurement jobs. Therefore,in reports providing performance indicators based on more than one measurement, there is the risk ofhaving multiple meanings for the same counter name. To guarantee unique counter references withinthe reports, counter names can be preceded by the SPOTS measurement name separated by colon,(i.e. <Spots Measurement>:<Counter Name>, for instance "C7LSET:NUM_UNA").The mapping between Siemens counter names and SPOTS counter names, and, the description ofSPOTS measurements, is provided within [22].

Page 10: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

10 E200301-01-214-V10.0I-01

Date & TimeThe fields on the reports described as "date" and as "Time" provide the date and time correspondingto the end of the granularity period, or, case aggregation of samples is performed, the end time of thelast granularity period included on the result. In order to keep the sample periods ending at 00:00attached to the data from the day before, the time-stamp for these samples is always changed to23:59 at the time of the loading into SPOTS database.

Default valueThe Default Values represent the value assigned to an Input Parameter case the user doesn't defineanother at the time of the report execution. The application will assume a default value because allvalues are mandatory when running the report.

DescriptionThe description will give you a short explanation about the content of the report and its main goals.

Detailed DataThe SPOTS data is organised in two logging tables:

− Detailed Data− Historical Data

The Detailed data is the raw PM data (typically with 15min granularity) stored in the database for alimited period of time, usually two weeks. Please refer also to the definition of Historical Data.

Input ParametersThese parameters define the selection of data that will be shown in the report. Examples of theseparameters are the period of time and the Network Elements (e.g. MSC, BSC, Cell, TRX) to which thedata corresponds, or, the kind of Aggregation that will be made over the time in order to show a singlevalue for each indicator analysed.Some Input Parameters are simply chosen while selecting the report. For instance, the aggregationcriterion is usually chosen by selecting one report variant from a folder named after that same reportand containing several variants each one using a different aggregation criterion.

Elementary ObjectIt means the lowest-level object (in the sense of the SPOTS object containment hierarchy, please referto [22]) for which the performance parameters of the report are evaluated (e.g. BSC, BTS, TRX,NODEB, RNC, UCELL or EXCHANGE).

Historical DataThe SPOTS data is organised in two logging tables:

− Detailed Data− Historical Data

The Detailed data is the raw PM data.The analysis of evolution trends of the PM counters requires observation over long periods of time.The existence of detailed records (usually every 15 minutes) is not appropriate for this type ofanalysis. This would mean keeping in the Database an information volume of an "unacceptable"dimension, both due to the required amount of storage capacity and to the performance degradation inthe access. As an alternative, the significant indicators should be evaluated from the Detailed data andonly those (Historical data) must be kept into the Database for long term.The base period for Historical data creation is the day. These are the significant retrieved from theDetailed data:

− Daily Totals− SPBH Daily Peaks

For more information about Detailed and Historical data, please refer to [21] chapter 1.6 "Internal DataOrganisation".

Page 11: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 11

KPIKey Performance Indicators. Please refer to [05], [17] and [19].

LayoutThe Layout field of the report descriptions can contain screenshots of the report output, and/or, atemplate table containing the column and the row titles that will be displayed on the report output (boldfont table cells). Additionally the table can also contain the formulas for the indicators (on the whitecells) and any other information that helps to provide a full description of the report concept (light greycells). This other information is usually the performance indicator full name or auxiliary headers forgroups of related performance indicators. Below is the template for the tables used in the descriptions:

Report NameExecution Parameters

Auxiliary HeaderPerformanceIndicator #1 Performance

Indicator #2PerformanceIndicator #3

AbbreviatedName #1

AbbreviatedName #2

AbbreviatedName #3

<Unit> <Unit> <Unit>

Date Time Object

<Threshold>

<Dat

e Fo

rmat

(e.g

. YYY

Y-M

M-D

D)>

<Tim

e Fo

rmat

(e.g

. HH

:mm

)>

<Obj

ect C

lass

ID>

KPI

des

crip

tion

and/

orFo

rmul

a

KPI

des

crip

tion

and/

orFo

rmul

a

KPI

des

crip

tion

and/

orFo

rmul

aNetwork ElementThe entity of the network (e.g. BSC, RNC, MSC or SGSN) to which the measurements are referred.

MeasurementsName of the Siemens scanners or measurement jobs required in order to have available all the dataused by the application to compute the report. For the mapping between the measurements asdefined above and SPOTS measurements, please refer to [22] chapter 2.2 - "Object classes andmeasurements". The list of counters for each SPOTS measurement and the object class to which itapplies, is also provided within [22].

Performance IndicatorCalculations based on performance measurement counters and aiming to provide meaningful resultsfor the performance analysis. A significant part of Performance Indicators used in the performancereports have direct correspondence to key performance indicators which are defined in documents[19] (for GERAN) and [17] (for UTRAN). The exact correspondence to the key performance indicatorsspecified in the Layout columns of each report description. There we can find the key performanceindicators always addressed by their short-name inside < > (e.g.: "<CSSuccRate>" equal to "value ofCSSuccRate"). The Performance Indicators that do not have a direct correspondence to a keyperformance indicator, have their calculation specified in the report layout columns using keyperformance indicators and/or performance measurement counters (which are not inside < > and, inmost cases, are identifiable be a suffix inside brackets, e.g. “NRDEFTCH[3]”).

Page 12: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

12 E200301-01-214-V10.0I-01

The naming convention for the performance measurement counters and calculations is the same usedand specified in [17] and [19]: For instance, for the used SBS performance measurement counters, theSBS short identification becomes the combination of measurement type and sub-counter. Ameasurement type can have several sub-counters. Therefore the used sub-counters are listed inbrackets with following meaning:

[1] sub-counter 1 has to be taken.[1,2,4] sub-counters 1, 2 and 4 have to be added.[1..4] sub-counters 1, 2, 3 and 4 have to be added.[1..4, 7..10] sub-counters 1, 2, 3, 4, 7, 8, 9 and 10 have to be added.[all] all sub-counters have to be added.

RemarksAdditional information about the report that didn't fit in any other information fields.

Report NameThis is the full name of the described performance report.

Report Short NameThis is a short name for the described performance report. It usually matches reports file names.

Target GroupsThis is the group of users for to which the report is mainly addressed. The following groups weredefined according to their task in the network:

− Network Operation− Network Optimisation− Network Planning− Marketing− Management

ThresholdThe Thresholds are suggested values to enable the comparison of correspondent indicator with areference value.The values assumed in this document are realistic thresholds based also on empirical knowledge andtherefore, in most cases, they can be adopted as the reference value for the respective indicator.Nevertheless they can depend on network configuration and other aspects that are implementationspecific. In those cases, they should be submitted to the appreciation of experts.

UnitThe unit is related to a performance indicator present in the report e.g. number (Nr), percent (%),Erlang (Erl), Erlang Second (Erl.s), second (sec) or minute (min).

Page 13: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 13

2 PU Load

2.1 Core Network

Page 14: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

14 E200301-01-214-V10.0I-01

2.1.1 MP Load Report

Report Name: MP Load Report

Report Short Name: mp

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: Reports the load of the node's main processors sorted by the date/time andthe node’s name.The PBH is evaluated based on "TotalAvgLoad".

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH Node Name

Measurements: VCPU

Remarks: None.

Page 15: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 15

Layout:

MP Load <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

TotalAvgLoad %Load PrhAvg

LoadOamAvg

LoadNrAvgLoad

BaseAvgLoad

CallpAvgLoad

mErl % mErl mErl mErl mErl mErlDate Time Object

YYYY

-MM

-DD

HH

:mm

<NE

Nam

e>

vcpu

00m

pTot

alAv

erag

eLoa

d - v

cpu1

6idl

eAve

rage

Load

(vcp

u00m

pTot

alAv

erag

eLoa

d - v

cpu1

6idl

eAve

rage

Load

) / 1

0

vcpu

02sl

tPrh

Aver

ageL

oad

vcpu

03oa

mAv

erag

eLoa

d

vcpu

06cc

s7N

mAv

erag

eLoa

d

vcpu

17sy

stem

Base

Load

Aver

ageL

oad

vcpu

04ca

llpAv

erag

eLoa

d

Page 16: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

16 E200301-01-214-V10.0I-01

2.1.2 CP Load Report

Report Name: CP Load Report

Report Short Name: cp

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: Reports the load of the NE’s main processors, sorted by date/time and NE’sname.The PBH is evaluated based on "CallPLoad".

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH NE Name

Measurements: CPMSC

Remarks: "Nproc" is the number of available processors with "TotalLoad" greater thanzero and different from NODATA.

Page 17: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 17

Layout:

CP Load <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

TotalLoad CallPLoad %CallPLoad CallPFactor SystemPanelLoad

mErl mErl % mErl mErlDate Time Object

<100 <670

YYYY

-MM-

DD

HH

:mm

<NE

Nam

e>

sum

(BAP

M.T

OTA

L IN

TEN

SITY

, ...

, CAP

9.TO

TAL

INTE

NSI

TY)

sum

(BAP

M. C

ARR

IED

TR

AFFI

C, .

.. , C

AP9.

CAR

RIE

D T

RAF

FIC

)

(<C

allP

Loa

d> /

(670

* <N

proc

>)) *

100

Mea

n C

P Lo

ad p

er P

roce

ssed

Cal

l

Mea

n Lo

ad o

f Pro

cess

ors

in th

e C

P

Page 18: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

18 E200301-01-214-V10.0I-01

2.2 Radio Access Network

Page 19: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 19

2.2.1 BSC Load Report

Report Name: BSC Load Report

Report Short Name: BscLoadReport

Target Groups: Network Operation, Network Optimisation Network Planning.

Description: The purpose of this report is to evaluate the BSC processors load evolutionthroughout the time.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) BSC BSC Symbolic Name

Input Parameters:

(e) AGGREGATION "TEVL""SPBH Daily Peaks"

Measurements: From SCANBSC functional group:BSCPRCLD

Remarks: This report is also available in SPOTS V10 for BR5.5 and BR5.0. Please notethat the list of PCUs is shorter in BR5.5 and doesn't existent in BR5.0.

Page 20: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

20 E200301-01-214-V10.0I-01

Layout:BS

C Lo

ad R

epor

t SPB

HSt

art D

ate: 0

2-02

-200

1En

d Date

: 25-

02-2

001

Page 21: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 21

2.2.2 NodeB Load Report

Report Name: NodeB Load Report

Report Short Name: NodeBLoadReport

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: The purpose of this report is to provide the evolution of the NodeB Load for aspecified period of time. The following indicators are presented in a chart for-mat: Call Processing Usage Ratio, Base Band Usage Ratio and Rest of CallCapacity.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) NODEB NodeB Symbolic Name

Input Parameters:

(e) AGGREGATION "TEVL""SPBH Daily Peaks"

Measurements: From NodeB:bbUsageRatiocpUsageRatiorestOfCallCapacity

Remarks: None.

Page 22: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

22 E200301-01-214-V10.0I-01

Layout:No

deB

Load

Rep

ort S

PBH

Daily

Pea

ksSt

art D

ate: 2

6-02

-200

1 00:0

0En

d Date

: 26-

02-2

001 2

3:00

Page 23: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 23

2.2.3 RNC Processor Load Report

Report Name: RNC Processor Load Report

Report Short Name: RNCProcLoadReport

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: The purpose of this report is to provide the evolution of the RNC total load andcall-processing load for a specified period of time.The report is presented in chart format.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) RNC RNC Symbolic Name

Input Parameters:

(e) AGGREGATION "TEVL""SPBH Daily Peaks"

Measurements: From RNC:rncUsageRatio

Remarks: None.

Page 24: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

24 E200301-01-214-V10.0I-01

Layout:RN

C Pr

oces

sor L

oad

Repo

rt TE

VLSt

art D

ate: 2

6-02

-200

1 00:0

0En

d Date

: 26-

02-2

001 2

3:00

Page 25: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 25

3 SS7 Surveillance

3.1 CCNC Platforms

Page 26: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

26 E200301-01-214-V10.0I-01

3.1.1 CCNC SS7 Switch Surveillance Report

Report Name: CCNC SS7 Switch Surveillance Report

Report Short Name: ccs7_switch_survey

Target Groups: Network Operation, Network Optimisation.

Description: This report is based on data relative to MSUs. It provides per NE the numberof MSUs handled, number of MSUs discarded and discard rate.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "DTOT"

"TEVL"

Input Parameters:

(e) EXCH NE Name

Measurements: C7DCDMSUC7MSU

Remarks: None.

Page 27: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 27

Layout:

CCNC SS7 Switch Surveillance <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

TotalMSUs DiscMSUs %DiscMSUs

Nr Nr %Date Time Object

YYYY

-MM

-DD

HH

:mm

<NE

Nam

e>

Tota

l num

ber o

f han

dled

MSU

s (In

com

ing

+ O

utgo

ing

+ Tr

ansi

t).

Num

ber o

f MSU

s di

scar

ded

due

to ro

utin

g da

ta e

rror

s

Perc

enta

ge o

f dis

card

ed M

SUs

Page 28: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

28 E200301-01-214-V10.0I-01

3.1.2 CCNC SS7 Route Set Surveillance Report

Report Name: CCNC SS7 Route Set Surveillance Report

Report Short Name: CC7RouteSetSurveillance

Target Groups: Network Operation, Network Optimisation.

Description: This report provides data relative to Route Set failures.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "DTOT"

"TEVL"(e) EXCH NE Name

Input Parameters:

(f) RA Route Set Id

Measurements: C7RSET

Remarks: None.

Layout:

CCNC SS7 Route Set Surveillance <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

UnEvents UnDuration %Una

Nr sec %Date Time Object

YYYY

-MM

-DD

HH

:mm

<Rou

te S

et Id

>

Num

ber o

f Rou

te S

et fa

ilure

s

Sum

of t

he d

urat

ion'

s of

Rou

te S

et fa

ilure

s

Perc

enta

ge o

f tim

e fo

r whi

ch R

oute

Set

s w

ere

infa

ilure

Page 29: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 29

3.1.3 CCNC SS7 Link Set Surveillance Report

Report Name: CCNC SS7 Link Set Surveillance Report

Report Short Name: ccs7_linkset_survey

Target Groups: Network Operation, Network Optimisation.

Description: This report is based on data referent to unavailability of link sets. A link set isconsidered to be unavailable when the last link in the set goes into state"inactive".

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "DTOT"

"TEVL"(e) EXCH NE Name

Input Parameters:

(f) C7LS Link Set Id

Measurements: C7LSET

Remarks: None.

Layout:

CCNC SS7 Link Set Surveillance <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

UnEvents UnDuration %Una

Nr sec %Date Time Object

YYYY

-MM

-DD

HH

:mm

<Lin

k Se

t Id>

Num

ber o

f Lin

k Se

ts o

ut o

f ser

vice

Dur

atio

n fo

r whi

ch L

ink

Sets

wer

e ou

t of s

ervi

ce

Perc

enta

ge o

f Out

of S

ervi

ce T

ime

Page 30: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

30 E200301-01-214-V10.0I-01

3.1.4 CCNC SS7 Link Surve illance Report

Report Name: CCNC SS7 Link Surveillance Report

Report Short Name: CC7SwitchSurveillance

Target Groups: Network Operation, Network Optimisation.

Description: This report presents some of the most important signalling link statistics. Itprovides a first overview of the link performance.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "DTOT"

"TEVL"(e) EXCH NE Name(f) C7LS Link Set Id

Input Parameters:

(g) C7LINK Link Id

Measurements: C7GOSC7LLOAD

Remarks: None.

Layout:

CCNC SS7 Link Surveillance <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

%InService %Una %Congestion ErrorMSUs

% % % NrDate Time Object

YYYY

-MM

-DD

HH

:mm

<Lin

k Se

t Id>

Perc

enta

ge o

f lin

k av

aila

ble.

Perc

enta

ge o

f lin

k un

avai

labl

e.

Perc

enta

ge o

f lin

k co

nges

tion.

Num

ber o

f MSU

s w

ith e

rror

.

Page 31: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 31

3.1.5 CCNC SS7 Link Load Report

Report Name: CCNC SS7 Link Load Report

Report Short Name: ccs7_link_load

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: Reports the load of the SS7 links assuming 64kbit/s links. This report provi-des the fundamental performance indicators for SS7 link dimensioning.The PBH is evaluated based on TotalLoad.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

(e) EXCH NE Name(f) C7LS Link Set id

Input Parameters:

(g) C7LINK Link id

Measurements: C7GOSC7LLOAD

Remarks: None.

Page 32: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

32 E200301-01-214-V10.0I-01

Layout:

Tota

lLo

ad Erl

max(<TotalTxTrf> , <TotalRxTrf>)

Tota

lRx

Trf

Erl Total Load in the Receiving direction

Tota

lTx

Trf

Erl Total Load in the Transmitting direction

Rx MSUs

Nr/se

c

Number of Received MSUs

Tx MSUs

Nr/se

c

Number of Transmitted MSUs

Rx SSOc

t

Nr Number of Received Information Octets

TxSS

Oct

Nr Number of Transmitted Information Octets

RetrO

ct

Nr Number of Retransmitted Octets

Tota

lEr

rorM

SUs

Nr Number of Erroed MSUs

Cong

estio

n

% Percentage of Congested Links

Unav

ailab

le

% Percentage of Unavailable Links

InSe

rvice

% Percentage of Links in Service

Objec

t

<Link Id>

Tim

e

HH:mm

CCNC

SS7

Lin

k Loa

d Re

port

<AGG

REGA

TION

>St

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 33: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 33

3.2 SSNC Platforms

Page 34: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

34 E200301-01-214-V10.0I-01

3.2.1 SSNC SS7 Node Surveillance Report

Report Name: SSNC SS7 Node Surveillance Report

Report Short Name: ss7_node

Target Groups: Network Operation, Network Optimisation.

Description: This report is based on data relative to MSUs. It provides, per NE, the num-ber of MSUs handled, number of MSUs discarded and discard rate.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""DTOT""TEVL"

Input Parameters:

(e) EXCH NE Name

Measurements: SEMSU

Remarks: None.

Layout:

SSNC SS7 Node Surveillance <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

IncMSUs OutMSUs TransitMSUs TotalMSU DiscMSUs %DiscMSUsNr Nr Nr Nr Nr %Date Time Object

YYYY

-MM

-DD

HH

:mm

<NE

Nam

e>

SEM

SU:n

umIn

MSU

SEM

SU:n

umO

utM

SU

SEM

SU:n

umTr

ansi

tMSU

<Inc

MU

Ss>

+ <O

utM

SUs>

+ <

Tran

sitM

SUs>

SEM

SU:n

umLo

stM

SUR

outE

rr

<Dis

cMSU

s> /

<Tot

alM

SUs>

* 10

0

Page 35: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 35

3.2.2 SSNC SS7 Sign Point Surveillance Report

Report Name: SSNC SS7 Sign Point Surveillance Report

Report Short Name: ss7_spoint

Target Groups: Network Operation, Network Optimisation.

Description: This report provides performance data related to SS7 signalling points concer-ning the inaccessibility of adjacent points and the number of discarded MSUs.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "DTOT"

"TEVL"(e) EXCH NE Name

Input Parameters:

(f) MTPSP MTP Signalling Point Id

Measurements: SPMSUSPUTL

Remarks: None.

Layout:

SSNC SS7 Sign Point Surveillance <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

AdjInacEvents AdjInacDuration %AdjInac DiscMSUs

Nr sec % NrDate Time Object

YYYY

-MM

-DD

HH

:mm

<MTP

Sig

nallin

g Po

int I

d>

SPU

TL:a

djac

entIn

acce

ssib

leEv

ents

SPU

TL:a

djac

entIn

acce

ssib

leD

urat

ion

<Adj

Inac

Dur

atio

n> /

T * 1

00

SPM

SU:d

isca

rded

MSU

s

Page 36: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

36 E200301-01-214-V10.0I-01

3.2.3 SSNC SS7 Route Set Surveillance Report

Report Name: SSNC SS7 Route Set Surveillance Report

Report Short Name: ss7_route

Target Groups: Network Operation, Network Optimisation.

Description: This report provides data relative to Route Set failures.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "DTOT"

"TEVL"(e) EXCH NE Name(f) MTPSP MTP Service Point Id

Input Parameters:

(g) SRSNP Route Set Id

Measurements: RSINF

Remarks: None.

Layout:

SSNC SS7 Route Set Surveillance <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

UnEvents UnDuration %Una

Nr sec %Date Time Object

YYYY

-MM

-DD

HH

:mm

<Rou

te S

et Id

>

RSI

NF:

rout

eSet

Una

vaila

ble

RSI

NF:

rout

eSet

Una

vaila

bleD

urat

ion

<UnD

urat

ion>

/ T

* 100

Page 37: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 37

3.2.4 SSNC SS7 Link Set Surveillance Report

Report Name: SSNC SS7 Link Set Surveillance Report

Report Short Name: ss7_linkset

Target Groups: Network Operation, Network Optimisation.

Description: This report concerns indicators referent to unavailability of link sets. Further-more, it provides also per link set, other indicators related with the links load.A link set is considered to be unavailable when the last link in the set goesinto state "inactive".The SUM operation should be done over all signalling links belonging to thesame link set.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "DTOT"

"TEVL"(e) EXCH NE Name(f) MTPSP MTP Service point Id

Input Parameters:

(g) SLS Link Set Id

Measurements: LSDURSLUTL

Remarks: None.

Page 38: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

38 E200301-01-214-V10.0I-01

Layout:

Disc

arde

dMS

Us Nr sum(SLUTL:discardedMSUs)

Retra

nsm

itted

Octe

ts

Nr sum(SLUTL:retransmittedOctets)Ou

tMSU

s

Nr/se

c

sum(SLUTL:transmittedMSUs)/T

IncM

SUs

Nr/se

c

sum(SLUTL:receivedMSUs)/T

OutS

IFSI

Os

Nr sum(SLUTL:transmittedOctectsSIFSIO)

IncS

IFSI

Os

Nr sum(SLUTL:receivedOctectsSIFSIO)

%Un

a

% <UnDuration> / T * 100

UnDu

ratio

n

Nr LSDUR:slsUnavailable

UnEv

ents

Nr LSDUR:numLinkSetNotAvail

Objec

t

<Link Set Id>

Tim

e

HH:mm

SSNC

SS7

Lin

k Set

Sur

veilla

nce R

epor

t <AG

GREG

ATIO

N>St

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 39: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 39

3.2.5 SSNC SS7 Link Surve illance Report

Report Name: SSNC SS7 Link Surveillance Report

Report Short Name: ss7_link

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: This report provides performance indicators concerning the SS7 links load.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "DTOT"

"TEVL"(e) EXCH NE Name(f) MTPSP MTP Service point Id(g) SLS Link Set Id

Input Parameters:

(h) SL Link Id

Measurements: SLCNGSLDURSLUTL

Remarks: None.

Page 40: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

40 E200301-01-214-V10.0I-01

Layout:

%Co

nges

tion

% <CongestionDuration> / T * 100

Cong

estio

nDu

ratio

n

sec SLCNG:slCongestionDuration

Cong

estio

nEv

ents

Nr SLCNG:slCongestedStarts

Disc

arde

dMS

Us Nr SLUTL:discardedMSUs

Retra

nsm

itted

Octe

ts

Nr SLUTL:retransmittedOctets

Out

MSUs

Nr/se

c

SLUTL:transmittedMSUs/T

Inc

MSUs

Nr/se

c

SLUTL:receivedMSUs/T

Out

SIFS

IOs

Nr SLUTL:transmittedOctectsSIFSIO

Inc

SIFS

IOs

Nr SLUTL:receivedOctectsSIFSIO

%Un

a

% SLDUR:slUnavailableDuration / T * 100

UnEv

ents

Nr SLDUR:slFailed

%In

Serv

ice

Nr SLDUR:slInServiceDuration / T * 100

Objec

t

<Link Id>

Tim

e

HH:mm

SSNC

SS7

Lin

k Sur

veilla

nce <

AGGR

EGAT

ION>

Star

t Date

: <ST

ART_

DATE

>En

d Date

: <EN

D_DA

TE>

Date YYYY-MM-DD

Page 41: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 41

4 Core Network

4.1 CS

Page 42: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

42 E200301-01-214-V10.0I-01

4.1.1 TGRP Load Report

Report Name: TGRP Load Report

Report Short Name: tgrp_load

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: Reports the load of the trunkGroups providing useful information both fordimensioning and for troubleshooting. Basic indicators like Mean HoldingTimes, Answer Seizure Ratios, Traffic Offered and Loss, are provided in thisreport.The PBH is evaluated based on "TGRPLoad = (TV:I + TV:O)".

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL""DTOT"

(e) EXCH NE Name

Input Parameters:

(f) TGRP TGRP Name

Measurements: TGRP

Remarks: – For incoming trunks, TV:IC=0;– For outgoing trunks, TV:O=0

Page 43: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 43

Layout 1:

MHT

sec

>40 Mean Holding Time of Carried Calls

ASR % >60 Answer Seizure Ratio of Carried Calls

Calls

Carr

Wth

Ans

Nr Calls Carried With Answer

Calls

Carr

Nr Calls CarriedCC:I + CC:O

Loss % <0.1 Erlang B Loss.

Traf

PerL

ine

Erl Traffic Carried per Line

Traf

Carr

Erl Traffic Carried

Traf

Off

Erl Traffic Offered

Req

Line

s

Nr Number of Required Lines

Serv

Line

s

Nr Number of Lines in Service

Conn

Line

s

Nr Connected Lines

Objec

t

<TGRP Name>

Tim

e

HH:mm

TGRP

Loa

d MA

X_SP

BH / S

PBH

Star

t Date

: <ST

ART_

DATE

>En

d Date

: <EN

D_DA

TE>

Date YYYY-MM-DD

Page 44: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

44 E200301-01-214-V10.0I-01

Layout 1 (cont):

CSCo

nges

tion

Nr

Calls released after trunk group seizure becausethe backward signal "congestion" was received from

downstream exchanges

CSSu

mTe

chIrr

Nr Calls released after trunk seizure due to technicalirregularities

CSSu

mSu

b

Nr Calls released after trunk seizure due to Subscriberirregularities

CSCC

S7Fa

il

Nr Calls failed after trunk group seizure because of releasesignal reception

CULo

stCa

lls

Nr Unsuccessful Calls offered to alternative routes

OutC

alls

CarrU

ns

Nr Unsuccessful Outgoing Calls; includes Calls rejected inthe first and in the alternative routes

OutC

alls

CarrW

thAn

s

Nr Outgoing Calls Carried With Answer

OutC

alls

Carr Nr Outgoing Calls Carried

IncC

alls

CarrW

thAn

s

Nr Incoming Calls Carried With Answer

IncC

alls

Carr Nr Incoming Calls Carried

Objec

t

<TGRP Name>

Tim

e

HH:mm

TGRP

Loa

d MA

X_SP

BH / S

PBH

Star

t Date

: <ST

ART_

DATE

>En

d Date

: <EN

D_DA

TE>

Date YYYY-MM-DD

Page 45: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 45

Layout 2:

Tran

sBlk

Line

s

Nr Transiently Blocked Lines

Sem

iBlk

Line

s

Nr Semi Blocked LinesOu

tAS

R % >60 Answer Seizure Ratio of Outgoing Calls

Inc

ASR % >60 Answer Seizure Ratio of Incoming Calls

Out

MHT

sec

>40 Mean Holding Time of Outgoing Calls

Inc

MHT

sec

>40 Mean Holding Time of Incoming Calls

ATBR % <0.1 Relative time for which all trunks were blocked

OutC

alls

CarrU

ns

Nr Outgoing Calls Caried Unsuccessful

OutC

alls

Carr Nr Outgoing Calls Carried

IncC

alls

CarrU

ns

Nr Incoming Calls Carried Unsuccessful

IncC

alls

Carr Nr Incoming Calls Carried

OutT

raf

Carr

Erl Outgoing Traffic Carried

IncT

raf

Carr

Erl Incoming Traffic Carried

Serv

Line

s

Nr Number of Lines in Service

Conn

Line

s

Nr Connected Lines

Objec

t

<TGRP Name>

Tim

e

HH:mm

TGRP

Loa

d DT

OTSt

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 46: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

46 E200301-01-214-V10.0I-01

Layout 3:

TGRP Load TEVLStart Date: <START_DATE>

End Date: <END_DATE>

CallsCarr CallsCarrWithAns ATBR ASR MHT

Nr Nr % % secDate Time Object

<0.1 >60 >40

YYYY

-MM

-DD

HH

:mm

<TG

RP

Nam

e>

Cal

ls C

arrie

d

Cal

ls C

arrie

d W

ith A

nsw

er

Rel

ativ

e tim

e fo

r whi

ch a

ll tr

unks

wer

e bl

ocke

d

Ans

wer

Sei

zure

Rat

io o

f Car

ried

Cal

ls

Mea

n H

oldi

ng T

ime

of C

arrie

d Ca

lls

Page 47: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 47

4.1.2 TGRP Load Type Report

Report Name: TGRP Load Type Report

Report Short Name: tgrp_load_type

Target Groups: Network Optimisation.

Description: Report the incoming and outgoing load of the trunkGroups at the peak hour.Basic indicators like Mean Holding Times, Answer Seizure Ratios, TrafficCarried and Blocking, are provided in this report per load type, namely,incoming and outgoing.The PBH is evaluated based on "TGRPLoad = (TV:I+TV:O).

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks"(e) EXCH NE Name

Input Parameters:

(f) TGRP TGRP Name

Measurements: TGRP

Remarks: None.

Page 48: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

48 E200301-01-214-V10.0I-01

Layout:

Tran

sBl

kLi

nes

Nr Transiently Blocked Lines

Sem

iBl

kLi

nes

Nr Semi Blocked Lines

ATBR % <0.1 Relative time for which all trunks were blocked

Bloc

kFa

ctor

% <0.1 Blocking Factor

Out

MHT

sec

>40 Mean Holding Time of Outgoing Calls

Out

ASR % >60 Answer Seizure Ratio of Outgoing Calls

Out

Calls

Carr

Uns

Nr Outgoing Calls Carried Unsuccessful

Out

Calls

Carr Nr Outgoing Calls Carried

Out

Call

Att Nr Outgoing Call Attempts

Inc

MHT

sec

>40 Mean Holding Time of Incoming Calls

Inc

ASR % >60 Answer Seizure Ratio of Incoming Calls

Inc

Calls

Carr

Uns

Nr Incoming Calls Carried Unsuccessful

Inc

Calls

Carr Nr Incoming Calls Carried

Inc

CallA

tt

Nr Incoming Call Attempts

Out

Traf

Carr

Erl Outgoing Traffic Carried

Inc

Traf

Carr

Erl Incoming Traffic Carried

Serv

Line

s

Nr Number of Lines in Service

Conn

Line

s

Nr Connected Lines

Objec

t

<TGRP Name>

Tim

e

HH:mm

TGRP

Loa

d Ty

pe R

epor

t <AG

GREG

ATIO

N>St

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 49: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 49

4.1.3 Dest Report

Report Name: Dest Report

Report Short Name: dest

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: Reports the load per Destination Directory Number. This report provides basicindicators like Mean Holding Times, Answer Seizure Ratios, Calls Carried andCalls Unsuccessful.The PBH is evaluated based on CallsCarr.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""DTOT""TEVL"

(e) EXCH NE Name

Input Parameters:

(f) ODEST Destination DirectoryNumber

Measurements: DEST

Remarks: None.

Page 50: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

50 E200301-01-214-V10.0I-01

Layout 1:

Rejec

tedC

alls

Nr

Rejected Calls, sum of unsuccessful calls due to:- congestion or subscriber busy in the own exchange

(CCU_CONGESTION);- network management action (CCU_NM_CODE_BLOCKING);

- lack of authorisation to access the outgoing trunk group(CCU_NM_TRUNK_BLOCKING);

- internal blocking in the SN (CCU_TECHN_IRREGULAR)Ca

llsTe

chIrr

eg

Nr Calls terminated after connection through the SN due to technicalfaults in the external exchange and in the own exchange

Calls

Subs

Busy

Nr Calls With Subscriber Busy

Calls

Wth

NoAn

s

Nr Calls With No Answer

Calls

Wth

IncD

ial

Nr Calls With Incomplete Dialling

MHT

Wth

Ans

sec

>60 Mean Holding Time of Calls With Answer

MHT

sec

>40 Mean Holding Time

ASR % >60 Answer Seizure Ratio

Traf

CW

thAn

s

Erl Traffic Carried for Calls With Answer

Traf

Carr

Erl Traffic Carried

Calls

CW

thAn

s

Nr Calls Carried With Answer

Calls

Carr Nr Calls Carried

Objec

t

<Destination Directory Number>

Tim

e

HH:mm

Dest

Rep

ort M

AX_S

PBH

/ SPB

HSt

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 51: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 51

Layout 2:

Dest Report DAILY / DETAILEDStart Date: <START_DATE>

End Date: <END_DATE

CallsCarr CallsCWthAns TrafCarr TrafC

WthAns ASR MHT MHTWthAns

Nr Nr Erl Erl % sec secDate Time Object

>60 >40 >60

YYYY

-MM

-DD

HH

:mm

<Des

tinat

ion

Dire

ctor

y N

umbe

r>

Cal

ls C

arrie

d

Cal

ls C

arrie

d W

ith A

nsw

er

Traf

fic C

arrie

d

Traf

fic C

arrie

d fo

r Cal

ls W

ith A

nsw

er

Ans

wer

Sei

zure

Rat

io

Mea

n H

oldi

ng T

ime

Mea

n H

oldi

ng T

ime

of C

alls

With

Ans

wer

Page 52: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

52 E200301-01-214-V10.0I-01

4.1.4 Flow Report

Report Name: Flow Report

Report Short Name: flow

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: Reports the load per pair Destination Directory Number - Originating Code.This report provides basic indicators like Mean Holding Times, Answer SeizureRatios, Calls Carried and Calls Unsuccessful.The PBH is evaluated based on CallsCarr.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""DTOT""TEVL"

(g) EXCH NE Name(h) ODEST Destination Directory

Number

Input Parameters:

(i) OFLOW Originating Code

Measurements: FLOW

Remarks: None.

Page 53: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 53

Layout 1:

Rejec

tedC

alls

Nr

Rejected Calls, sum of unsuccessful calls due to:- congestion or subscriber busy in the own exchange

(CCU_CONGESTION);- network management action (CCU_NM_CODE_BLOCKING);

- lack of authorisation to access the outgoing trunk group(CCU_NM_TRUNK_BLOCKING);

- internal blocking in the SN (CCU_TECHN_IRREGULAR)Ca

llsTe

chIrr

eg

Nr Calls terminated after connection through the SN due to technicalfaults in the external exchange and in the own exchange

Calls

Subs

Busy

Nr Calls With Subscriber Busy

Calls

Wth

NoAn

s

Nr Calls With No Answer

Calls

Wth

IncD

ial

Nr Calls With Incomplete Dialling

MHT

Wth

Ans

sec

>60 Mean Holding Time of Calls With Answer

MHT

sec

>40 Mean Holding Time

ASR % >60 Answer Seizure Ratio

Traf

CW

thAn

s

Erl Traffic Carried for Calls With Answer

Traf

Carr

Erl Traffic Carried

Calls

CW

thAn

s

Nr Calls Carried With Answer

Calls

Carr Nr Calls Carried

Objec

t

<Originating Code>

Tim

e

HH:mm

Flow

Rep

ort M

AX_S

PBH

/ SPB

HSt

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 54: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

54 E200301-01-214-V10.0I-01

Layout 2:

Flow Report DAILY / DETAILEDStart Date: <START_DATE>

End Date: <END_DATE

CallsCarr CallsCWthAns TrafCarr TrafC

WthAns ASR MHT MHTWthAns

Nr Nr Erl Erl % sec secDate Time Object

>60 >40 >60

YYYY

-MM

-DD

HH

:mm

<Orig

inat

ing

Cod

e>

Cal

ls C

arrie

d

Cal

ls C

arrie

d W

ith A

nsw

er

Traf

fic C

arrie

d

Traf

fic C

arrie

d fo

r Cal

ls W

ith A

nsw

er

Ans

wer

Sei

zure

Rat

io

Mea

n H

oldi

ng T

ime

Mea

n H

oldi

ng T

ime

of C

alls

With

Ans

wer

Page 55: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 55

4.1.5 PBX Load Report

Report Name: PBX Load Analysis Report

Report Short Name: pbx

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: Reports the load of the PBXs providing useful information for dimensioningand for troubleshooting. Basic indicators like Mean Holding Times, AnswerSeizure Ratios, Traffic Offered and Loss, are provided in this report.The PBH is evaluated based on "PBXLoad = (TV:I + TV:O)".

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks"(e) EXCH NE Name

Input Parameters:

(f) PBXDN PBX Directory Number

Measurements: PBXD

Remarks: None.

Page 56: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

56 E200301-01-214-V10.0I-01

Layout:

CURe

jCa

lls Nr 0 Number of unsuccessful attempts in the CP to seize the trunk group

Calls

AnsO

ut

Nr Outgoing Calls With AnswerCa

llsOu

t

Nr Outgoing Calls

Calls

AnsIn

c

Nr Incoming Calls With Answer

Calls Inc Nr Incoming Calls Carried

MHT

sec

>40 Mean Holding Time of Carried Calls

ASR % >60 Answer Seizure Ratio

Calls

Carr

Wth

Ans

Nr Calls Carried With Answer

Calls

Carr Nr Calls Carried

Loss % <0.1 Erlang B Loss

Traf

Per

Line Erl Traffic Carried per Channel

Traf

Carr

Erl Traffic Carried

Traf Off

Erl Traffic Offered

Req

Line

s

Nr Number of Required Lines

Serv

Line

s

Nr Channels in Service

Conn

Line

s

Nr Connected Lines

Objec

t

<PBX Directory Number>

Tim

e

HH:mm

PBX

Load

<AGG

REGA

TION

>St

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 57: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 57

4.1.6 PBX Service Load Report

Report Name: PBX Service Load Report

Report Short Name: pbxs

Target Groups: Network Optimisation.

Description: Reports the load per PBX service. This report provides basic indicators likeMean Holding Times, Answer Seizure Ratios, Calls Carried and TrafficCarried.The PBH is evaluated based on "PbxServiceLoad = (TV_IC+TV_OO)".

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks"(e) EXCH NE Name

Input Parameters:

(f) PBXS PBX Directory Nr,concatenated with theService Id

Measurements: PBXS

Remarks: None.

Page 58: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

58 E200301-01-214-V10.0I-01

Layout:

Out

MHT

Wth

Ans

sec

>60 Mean Holding Time of Carried Outgoing Calls With Answer

Out

MHT

sec

>40 Mean Holding Time of Carried Outgoing Calls

Out

ASR % >60 Answer Seizure Ratio of Carried Outgoing Calls

Out

Calls

Carr Nr Outgoing Calls Carried

Out

Traf

Carr

Erl Outgoing Traffic Carried

Inc

MHT

Wth

Ans

sec

>60 Mean Holding Time of Carried Incoming Calls With Answer

Inc

MHT

sec

>40 Mean Holding Time of Carried Incoming Calls

Inc

ASR % >60 Answer Seizure Ratio of Carried Incoming Calls

Inc

Calls

Carr Nr Incoming Calls Carried

Inc

Traf

Carr

Erl Incoming Traffic Carried

MHT

Wth

Ans

sec

>60 Mean Holding Time of Carried Calls With Answer

MHT

sec

>40 Mean Holding Time of Carried Calls

ASR % >60 Answer Seizure Ratio

Calls

CW

thAn

s

Nr Calls Carried With Answer

Calls

Carr Nr Calls Carried

Traf

CW

thAn

s

Erl Traffic Carried With Answer

Traf

Carr

Erl Traffic Carried

Objec

t

<PBX Directory Number>

Tim

e

HH:mm

PBX

Serv

ice L

oad

Repo

rt <A

GGRE

GATI

ON>

Star

t Date

: <ST

ART_

DATE

>En

d Date

: <EN

D_DA

TE>

Date YYYY-MM-DD

Page 59: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 59

4.1.7 MSC VLR Surveillance

4.1.7.1 MSC Grade of Service Report

Report Name: MSC Grade of Service Report

Report Short Name: MscGosReport

Target Groups: Network Operation, Network Optimisation, Marketing & Management.

Description: This report provides an overview of some of the most meaningful indicatorsrelated with the MSC performance and Grade Of Service.In detail it provides the success rates for the most important GSM proce-dures, namely Call Setup, Handover, Location Update, Paging and ShortMessage Service. It also provides Load/Overload indicators that are relatedwith the load of the MSC processors. Furthermore it also provides severalfailure rates referring to different reasons for Call Setup failure.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: CPMSCVLR

Remarks: None.

Page 60: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

60E200301-01-214-V10.0I-01

Layout:

SMS

smsSR

%

PAG

pagSR

%

>90

LUP

lupSR

%

>95

HO

hoSR

%

>85

MTC

mtcSR

%

>95

MOC (PLMN)

plmnMocSR

%

>95

Success Rates

MOC (PSTN)

pstnMocSR

%

>95

Object

<NE N

ame>

Time

HH

:mm

MSC Grade Of Service Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 61: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0161

Layout (cont):

TCHCongestion

(MTC)

mtcTchCon

%

<5

TCHCongestion

(MOC)

mocTchCon

%

<5

BSSAPCongestion

(MTC)

mtcBssapCon

%

0

BSSAPCongestion

(MOC)

mocBssapCon

%

0

BSSAPOverload

(MTC)

mtcBssapOvl

%

0

BSSAPOverload[MICTR]

micBssapOvl

%

0

BSSAPOverload(MORTR)

mocBssapOvl

%

0

cpLoad

%

<100

CP Load

cpLoadperProc

mErl

<700

Call SetupTime

cSetTime

sec

<6

Object

<NE N

ame>

Time

HH

:mm

MSC Grade Of Service Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 62: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

62E200301-01-214-V10.0I-01

Layout (cont):

ReleaseBeforeACM

relBefACM

%

<1

ProtocolError

(MTC)

mtcProtoErr

%

<1

ProtocolError

(MOC)

mocProtoErr

%

<1

ServiceCheck(MTC)

mtcSvcChk

%

<1

ServiceCheck(MOC)

mocSvcChk

%

<1

Base StatioReason(MTC)

mtcBSReas

%

<1

Base StationReason(MOC)

mocBSReas

%

<1

TechnicalFault

(MTC)

mtcTecFault

%

<1

TechnicalFault

(MOC)

mocTecFault

%

<1

RequestDestination

Error(MTC)

mtcReqDestErr

%

<1

Failure Rates

RequestDestination

Error(MOC)

mocReqDestErr

%

<1

Object

<NE N

ame>

Time

HH

:mm

MSC Grade Of Service Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 63: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 63

4.1.7.2 VLR Load Analysis Report

Report Name: VLR Load Analysis Report

Report Short Name: VlrLoadReport

Target Groups: Network Optimisation.

Description: This report provides information about average subscriber behaviour in termsof Traffic Volume produced and procedures performed (namely, Handovers,Location Updates, Busy Hour Call Attempts, etc). In summary, it enables thecreation of a precise traffic model based on values obtained from real data.It also informs about the authentication procedure success rate and the num-ber of subscribers currently on the Visitor Location Register.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: MSCVLR

Remarks: None.

Page 64: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

64E200301-01-214-V10.0I-01

Layout:

AuthenticationSuccess

Rate

authSR

%

MSRN perSubscriber

msrnSub

Nr

LocationUpdates perSubscriber

lUpSub

Nr

Inter MSCHO per

Subscriber

itcMscHoSub

Nr

Intra MSCHO per

Subscriber

itrMscHoSub

Nr

MSCControlled

HO perSubscriber

mscHoSub

Nr

Traffic perSubscriber

trafSub

Erl.s

BHCA INper

Subscriber

bhcaInSub

Nr

BHCA perSubscriber(WithoutTRANS)

bhcaNoTransSub

Nr

BHCA perSubscriber

bhcaSub

Nr

Number ofVLR

Subscribers

subs

Nr

Object

<NE N

ame>

Time

HH

:mm

VLR Load Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 65: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 65

4.1.7.3 Mobile Originating Calls Analysis Report

Report Name: Mobile Originating Calls Analysis Report

Report Short Name: MocAnalysisReport

Target Groups: Network Optimisation.

Description: This report provides basic information about the Mobile Originating Calls likethe average duration, the Answer Seizure Ratio and the percentage of termi-nations due to No-answer or Busy destination.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: MSC

Remarks: None.

Page 66: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

66E200301-01-214-V10.0I-01

Layout:

Success Rate

plmnSR

%

>95

Others

plmnOthers

%

Busy

plmnBusy

%

A-Release

plmnARel

%

No Answer

plmnNoAsw

%

Answer

plmnAsr

%

AverageCall Duration

plmnMht

sec

PLMN

TotalCall Attempts

plmnCA

Nr

Object

<NE N

ame>

Time

HH

:mm

Mobile Originating Calls Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 67: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0167

Layout (cont):

Success Rate

pstnSR

%

>95

Others

pstnOthers

%

Busy

pstnBusy

%

A-Release

pstnARel

%

No Answer

pstnNoAsw

%

Answer

pstnAsr

%

AverageCall Duration

pstnMht

sec

PSTN

TotalCall Attempts

pstnCA

Nr

Object

<NE N

ame>

Time

HH

:mm

Mobile Originating Calls Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 68: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

68 E200301-01-214-V10.0I-01

4.1.7.3.1 UMTS Mobile Originating Calls Analysis Report

Report Name: UMTSMobile Originating Calls Analysis Report

Report Short Name: UMocAnalysisReport

Target Groups: Network Optimisation.

Description: This report provides basic information about the UMTS Circuit SwitchedMobile Originating Calls on the UMSC. Examples of this information are theaverage duration, the Answer Seizure Ratio and the percentage of termina-tions due to No-answer or Busy destination.The information provided here is similar to the one provided by the "MobileOriginating Calls Analysis" report, the main difference is that the indicators onthis report are referred only to UMTS calls and the other report aims all typesof calls, both GSM and UMTS.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: MSC

Remarks: None.

Page 69: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0169

Layout:

Success Rate

plmnSR

%

>95

Others

plmnOthers

%

Busy

plmnBusy

%

A-Release

plmnARel

%

No Answer

plmnNoAsw

%

Answer

plmnAsr

%

AverageCall Duration

plmnMht

sec

PLMN

TotalCall Attempts

plmnCA

Nr

Object

<NE N

ame>

Time

HH

:mm

UMTS Mobile Originating Calls Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 70: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

70E200301-01-214-V10.0I-01

Layout (cont):

Success Rate

pstnSR

%

>95

Others

pstnOthers

%

Busy

pstnBusy

%

A-Release

pstnARel

%

No Answer

pstnNoAsw

%

Answer

pstnAsr

%

AverageCall Duration

pstnMht

sec

PSTN

TotalCall Attempts

pstnCA

Nr

Object

<NE N

ame>

Time

HH

:mm

UMTS Mobile Originating Calls Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 71: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 71

4.1.7.4 Mobile Terminating Calls Analysis Report

Report Name: Mobile Terminating Calls Analysis Report

Report Short Name: MtcAnalysisReport

Target Groups: Network Optimisation.

Description: This report provides basic information about the Mobile Terminating Calls likethe average duration, the Answer Seizure Ratio and the percentage of termi-nations due to No-answer or Busy destination.Additionally, it shows other statistics related with the completion of the pagingprocedure.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: MSC

Remarks: None.

Page 72: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

72E200301-01-214-V10.0I-01

Layout:

MS-Blocked

msBloc

%

A-Release

aRel

%

Busy

busy

%

No Answer

noAsw

%

Answer

asr

%

AverageCall Duration

mht

sec

Calls WithTCH Allocation

tchAlloc

%

MTCSuccess Rate

mtcSR

%

>95

Calls

TotalCall Attempts

mtcCA

Nr

Object

<NE N

ame>

Time

HH

:mm

Mobile Terminating Call Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 73: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 73

Layout (cont):

Mobile Terminating Call Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Calls Paging

CallForwarding Others Started Paging

ProceduresPaging

ResponsePaging

Time OutMTC

Setup Rate

forw others startPag pagRes pagTiOut mtcSepRate

% % Nr % % %

Date Time Object

>90

YYYY

-MM

-DD

HH

:mm

<NE

Nam

e>

Page 74: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

74 E200301-01-214-V10.0I-01

4.1.7.4.1 UMTS Mobile Terminating Calls Analysis Report

Report Name: UMTS Mobile Terminating Calls Analysis Report

Report Short Name: UMtcAnalysisReport

Target Groups: Network Optimisation.

Description: This report provides basic information about the UMTS Circuit SwitchedMobile Terminating Calls. Examples of this information are the average dura-tion, the Answer Seizure Ratio and the percentage of terminations due to No-answer or Busy destination.The information provided here is similar to the one provided by the "MobileTerminating Calls Analysis Report", the main difference is that the indica-tors on this report are referred only to UMTS calls and the other report aimsall types of calls, both GSM and UMTS.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: MSC

Remarks: None.

Page 75: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0175

Layout:

MTCSetupRate

mtcSepRate

%

>90

Paging

ReceivedPaging

Responses

pagRes

Nr

Others

others

%

CallForwarding

forw

%

A-Release

aRel

%

Busy

busy

%

NoAnswer

noAsw

%

Answer

asr

%

AverageCall

Duration

mht

sec

Calls WithTCH

Allocation

tchAlloc

%

MTCSuccess Rate

mtcSR

%

>95

Calls

Total CallAttempts

mtcCA

Nr

Object

<NE N

ame>

Time

HH

:mm

UMTS Mobile Terminating Calls Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 76: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

76 E200301-01-214-V10.0I-01

4.1.7.5 Handover Analysis Report

Report Name: Handover Analysis Report

Report Short Name: HoAnalysisReport

Target Groups: Network Optimisation.

Description: This report details the causes of handovers and the success rates for severaldifferent types of handover (the type of handover depends on the networknodes involved in the procedure).

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: MSC

Remarks: None.

Page 77: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0177

Layout:

BetterCell

betCellHoRate

%

Quality

quHoRate

%

Causes

Strength

strHoRate

%

HO Fail

hoFail

%

HO NotAllowed

hoNotAllow

%

InterMSC B

SuccessRate

iteMscBSR

%

InterMSC A

SuccessRate

iteMscASR

%

Intra MSCSuccess

Rate

itrMscSR

%

HOFailure Rate

hoFR

%

HOSuccess Rate

hoSR

%

>85

General

Total HOAttempts

attHo

Nr

Object

<NE N

ame>

Time

HH

:mm

Handover Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 78: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

78 E200301-01-214-V10.0I-01

4.1.7.5.1 UMTS Handover Anal ysis Report

Report Name: UMTS Handover Analysis Report

Report Short Name: UHoAnalysisReport

Target Groups: Network Optimisation.

Description: This report details the causes of handovers and the success rates for severaldifferent types of UMTS handover (the type of handover depends on thenetwork elements involved in the procedure).The information provided here is similar to the one provided by "HandoverAnalysis Report"; the main difference is that the indicators on this report arereferred only to Handovers performed on UMTS calls and the other reportaims handovers performed on all types of calls, both GSM and UMTS.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: MSC

Remarks: None.

Page 79: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0179

Layout:

Successful InterMSC HO fromUMTS to GSM

iteUmtsGsmHoSuc

Nr

Successful IntraMSC HO fromUMTS to GSM

itrUmtsGsmHoSuc

Nr

Inter MSC BSuccess Rate

iteMscBSR

%

Inter MSC ASuccess Rate

iteMscASR

%

Intra MSCSuccess Rate

itrMscSR

%

HOFailure Rate

hoFR

%

HOSuccess Rate

hoSR

%

>85

Total HOAttempts

attHo

Nr

Object

<NE N

ame>

Time

HH

:mm

UMTS Handover Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 80: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

80 E200301-01-214-V10.0I-01

4.1.7.6 Location Update Ana lysis Report

Report Name: Location Update Analysis Report

Report Short Name: LupAnalysisReport

Target Groups: Network Optimisation.

Description: This report provides the success rate of the Location Update procedure, itdetails this value for inter and intra VLR, and provides the proportions of bothtypes of LUP related to the total of LUP procedures performed.It also provides the frequency of IMSI attaches performed together with theLocation Updates.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: VLR

Remarks: None.

Page 81: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0181

Layout:

AverageCombinedLUP Time

avgCombLupTi

sec

CombinedLUP

SuccessRate

combLupSR

%

Combined LUP (only SR9.0 on)

Requestsfor

CombinedLUP

reqCombLup

Nr

AverageLUPTime

avgLupTi

sec

<6

PeriodicLUPRate

perLupRate

%

IMSIAttachRate

imsiAtchRate

%

InterVLRRate

iteVlrRate

%

IntraVLRRate

itrVlrRate

%

InterVLR

Success

iteVlrSuc

%

IntraVLR

Success

itrVlrSuc

%

LUPIMSI

Success

lupImsiSuc

%

LUPSuccess

lupSuc

%

>95

General

Requestsfor LUP

lupReq

Nr

Object

<NE N

ame>

Time

HH

:mm

Location Update Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 82: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

82 E200301-01-214-V10.0I-01

4.1.7.7 Short Message Service Analysis Report

Report Name: Short Message Service Analysis Report

Report Short Name: SmsAnalysisReport

Target Groups: Network Optimisation.

Description: This report informs the operator about failure reasons and success rate rela-ted to the Short Message Service.It also details the information for incoming and outgoing Short Messages.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: MSC

Remarks: None.

Page 83: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0183

Layout:

UnidentifiedSubscriber

outUnidSub

%

OutgoingDelivery

Fail

outDelFail

%

OutgoingSuccess

outSuc

%

Outgoing

SMSattempts

outAtt

Nr

AbsentSubscriber

incAbsSub

%

IncomingDelivery

Fail

incDelFail

%

IncomingSuccess

incSuc

%

Incoming

SMSAttempts

incAtt

Nr

OtherReasons

otherReas

%

SMSDelivery

Fail

smsDelFail

%

SMSFailure

smsFail

%

Total

SMSSuccess

smsSuc

%

Object

<NE N

ame>

Time

HH

:mm

Short Message Service Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 84: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

84 E200301-01-214-V10.0I-01

4.1.7.8 Data And Fax Analysis Report

Report Name: Data And Fax Analysis Report

Report Short Name: DataFaxAnalysisReport

Target Groups: Network Optimisation.

Description: This report informs the operator about the success rates related to all types ofFax and Data services available. It details the information for each dataservice, namely: Circuit Duplex Synchronous and Asynchronous, AlternateSpeech/Data or Speech Followed by Data Services, and also for eachFacsimile service. It also details the information for each type of traffic (e.g.MTC, MOC PLMN or MOC PSTN).

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: MSC

Remarks: None.

Layout:

Data And Fax Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

General

Fax CallAttempts Fax Ratio Fax Answer

RateData CallAttempts Data Ratio

faxAtt faxRate faxASR dataAtt dataRate

Nr % % Nr %

Date Time Object

YYYY

-MM

-DD

HH

:mm

<NE

Nam

e>

Page 85: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0185

Layout (cont):

plmnFax3SR

%

Fax Group 3

plmnFax3

Nr

plmnCdsDigSR

%

Alternate FaxSpeech

plmnCdsDig

Nr

plmnCdsAnlg

SR

%

CDS Digital

plmnCdsAnlg

Nr

plmnCdaDigSR

%

CDSAnalogue

plmnCdaDig

Nr

plmnCdaDigSR

%

CDA Digital

plmnCdaDig

Nr

plmnCdaAnlgSR

%

Success Rates (MOC PLMN)

CDAAnalogue

plmnCdaAnlg

Nr

General

Data Answer Rate

dataASR

%

Object

<NE N

ame>

Time

HH

:mm

Data And Fax Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 86: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

86E200301-01-214-V10.0I-01

Layout (cont):

pstnSpch

DataSR

%

AlternateSpeech Data

pstnSpchData

Nr

pstnFax3SR

%

Fax Group 3

pstnFax3

Nr

pstnFax

SpchSR

%

AlternateFax Speech

pstnFaxSpch

Nr

pstnCds

DigSR

%

CDS Digital

pstnCdsDig

Nr

pstnCds

AnlgSR

%

CDS Analogue

pstnCdsAnlg

Nr

pstnCda

DigSR

%

CDA Digital

pstnCdaDig

Nr

pstnCda

AnlgSR

%

Success Rates (MOC PSTN)

CDA Analogue

pstnCdaAnlg

Nr

plmnSpch

DataSR

%

Success Rates(MOC PLMN)

AlternateSpeech Data

plmnSpchData

Nr

Object

<NE N

ame>

Time

HH

:mm

Data And Fax Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 87: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0187

Layout (cont):

mtcSpch

DataSR

%

AlternateSpeech Data

mtcSpchData

Nr

mtcFax3SR

%

Fax Group 3

mtcFax3

Nr

mtcFax

SpchSR

%

AlternateFax Speech

mtcFaxSpch

Nr

mtcCds

DigSR

%

CDS Digital

mtcCdsDig

Nr

mtcCds

AnlgSR

%

CDS Analogue

mtcCdsAnlg

Nr

mtcCda

DigSR

%

CDA Digital

mtcCdaDig

Nr

mtcCda

AnlgSR

%

Success Rates (MTC)

CDA Analogue

mtcCdaAnlg

Nr

Object

<NE N

ame>

Time

HH

:mm

Data And Fax Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 88: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

88 E200301-01-214-V10.0I-01

4.1.7.9 MSC Call Flow Report

Report Name: MSC Call Flow Report

Report Short Name: MscCallFlowReport

Target Groups: Network Operation, Network Optimisation, Network Planning, Marketing &Management.

Description: This report aims to support the Operation/Planning of the SSS Network.It provides general information about the load situation at a Mobile SwitchingCentre. It gives an overview of the traffic flow in the MSC distinguishingbetween different types of traffic. The type of traffic depends on the origin anddestination of the related calls.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: MSCVLR

Remarks: None.

Page 89: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 89

Layout:

Page 90: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

90 E200301-01-214-V10.0I-01

4.1.7.10 MSC Handover Flow Report

Report Name: MSC Handover Flow Report

Report Short Name: MscHoFlowReport

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: This report provides information about the MSC controlled handovers. Infor-mation is provided on the number of handovers attempted by each origin cellper target cell.This report can be used to obtain an overview of the traffic flow betweenCells, and the success rates per target Cell.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "DTOT"

"SPBH Daily Peaks""TEVL"

Input Parameters:

(e) EXCH MSC/VLR Name

Measurements: HOTRF

Remarks: None.

Layout:

MSC Handover Flow Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Number Of HO Success Rateho hoSRNr %

Date Time Object

>85

YYYY

-MM

-DD

HH

:mm

<Orig

in L

AC_C

ell-I

d>:<

Targ

et L

AC_C

ell-I

d>

Page 91: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 91

4.2 PS

Throughout this chapter some specific notation was used in order to enable the share of descriptionsbetween reports which apply to different PO versions, namely PO1.0, PO2.0 and PO2.1, or differentnetwork releases, namely GPRS (2G) and UMTS (3G):

Thus, if a column has the indication "PO1" typed in bold, it means that the column only exists if thatreport was executed with data from NEs versions PO1.0 or GR2.0. An analogous interpretation shouldbe applied to columns displaying "PO2" typed in Bold. Furthermore, if a formula is preceded by theindication "PO1:" typed in bold, it means that that formula it's only valid for PO1.0 or GR2.0 equipmentversion, another formula (preceded by "PO2:") describes the same indicator for PO2.0, PO2.1 orGR3.1 equipment version.

The string "[2G + 3G]" inside the counter name field (e.g. attActPdpContext[2G+3G]) means the sum ofthe counters with the same name but measured via different scanners, one scanner for 2G protocolmeasurements and the other for 3G protocol measurements, (e.g. attActPdpContext[2G+3G] =attActPdpContext@sgsn2gSmCurrentData + attActPdpContext@sgsn3gSmCurrentData).

When the execution parameter <xG> appears in the report's title, it means that the report results referonly to one of the two protocols, GPRS (case <xG> = "2G") or UMTS (case <xG> = "3G").

Page 92: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

92 E200301-01-214-V10.0I-01

4.2.1 ATM SP on xGSN

4.2.1.1 GTP Throughput Report

Report Name: GTP Throughput Report

Report Short Name: GtpThputReport

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: This report provides information regarding the number of packets and thethroughput transmitted via GTP (GPRS Tunnelling Protocol) per SP:GTP onany type of GSN, to help determine the efficiency of the network.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""TEVL"

(e) EXCH xGSN Name(f) ATMSW 36140 Name

Input Parameters:

(g) CARD SP Card Name

Measurements: GPRS-gtp

Remarks: None.

Page 93: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0193

Layout:

Out

outThput

kbps

8 * gtpOutSigO

ctets / (1000 * T)

Signalling ThroughputPO2

In

inThput

kbps

8 * gtpInSigOctets / (1000 * T)

Out

outSigPkts

Pkt/s

gtpOutSigPkts / T

Number of SignallingPackets per Second

In

inSigPkts

Pkt/sgtpInSigPkts / T

Out

outThput

kbps

8 * gtpOutD

ataOctets / (1000 * T)

Data ThroughputPO2

In

inThput

kbps

8 * gtpInDataO

ctets / (1000 * T)

Out

outDataPkts

Pkt/s

gtpOutD

ataPkts / T

Number of Data Packetsper Second

In

inDataPkts

Pkt/s

gtpInDataPkts / T

RejectedIncomingPackets

PO2

inRejPkts

Nr

gtpInRejectedPkts

Object

<SP Card N

ame>

Time

HH

:mm

GTP Throughput Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 94: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

94 E200301-01-214-V10.0I-01

4.2.2 GGSN

4.2.2.1 Virtual Router Load Report

Report Name: Virtual Router Load Report

Report Short Name: VggsnLoadReport

Target Groups: Network Operation, Network Optimisation.

Description: Each virtual router is configured with a maximum number of simultaneoussessions, a maximum throughput and an IP address range. This report ena-bles the detection of problems related to the session establishment due toviolations of the maximum number of simultaneous sessions or due to lack ofIP addresses. It also detects situations of routing failures, which can be rela-ted to overload or destination error.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""DTOT""TEVL"

(e) EXCH GGSN Name(f) ATMSW 36140Name(g) CARD SP Card Name

Input Parameters:

(h) VRINDEX Virtual Router Index

Measurements: GPRS-gi

Remarks: None.

Page 95: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0195

Layout:

Number ofSessionsThresholdExceeded

sessThExcd

Nr

giNbrSessU

pperthresholdExceed

Number ofRefused

Sessions dueto lack of

IP Address

lackIpAdd

Nr

giNbrO

fRefusedSessionsLackIpAddress

Total Number of RefusedSessions

refSess

Nr

giNbrR

efusedSess

Number ofSessions

Established

sucSess

NrgiN

brSuccSess

Downlink

routSRDL

%

100 * giNbrPosD

ownlinkPackets /

/ (giNbrPosD

ownlinkPackets +

+ giNbrN

egDow

nlinkPackets)

Routing Success Rate

Uplink

routSRUl

%

100 * giNbrPosU

plinkPackets // (giN

brPosUplinkPackets +

+ giNbrN

egUplinkPackets)

Downlink

routFailDl

Pkt/s

giNbrN

egDow

nlinkPackets / T

Packet RoutingFailures per Second

Uplink

routFailUl

Pkt/s

giNbrN

egUplinkPackets / T

Downlink

sucRoutDl

Pkt/s

giNbrPosD

ownlinkPackets / T

Packets per SecondSuccessfully Routed

Uplink

sucRoutUl

Pkt/s

giNbrPosU

plinkPackets / T

Object

<Virtual Router Index>

Time

HH

:mm

Virtual Router Load Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 96: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

96 E200301-01-214-V10.0I-01

4.2.2.2 ISP Session Analysis Report

Report Name: ISP Session Analysis Report

Report Short Name: IspSessionReport

Target Groups: Network Operation, Network Optimisation, Marketing & Management.

Description: This report provides a detailed analysis of ISP sessions per virtual router,including the related statistics regarding activation, deactivation and modifica-tion of sessions.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""DTOT""TEVL"

(e) EXCH GGSN Name(f) ATMSW 36140Name(g) CARD SP Card Name

Input Parameters:

(h) APN Access Point Name

Measurements: GPRS-apn

Remarks: None.

Page 97: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 97

Layout:

Modif

icatio

nspe

r Ses

sion

mod

Sess

Nr tspscApnSuccModifySessions // tspscApnSuccActivateSessions

Modif

icatio

nSu

cces

sRa

te

mod

SR % 100 * tspscApnSuccModifySessions // tspscApnAttModifySessions

Numb

er of

Sess

ions

Modif

ied

sess

Mod

Nr tspscApnSuccModifySessionsGG

SN

deac

SRGg

sn

% 100 * tspscApnSuccDeactivateSessionsGgsn // tspscApnAttDeactivateSessionsGgsn

Deac

tivati

onSu

cces

s Rate

MS deac

SRMs % 100 * tspscApnSuccDeactivateSessionsMs /

/ tspscApnAttDeactivateSessionsMs

GGSN

sess

Deac

Ggsn

Nr tspscApnSuccDeactivateSessionsGgsn

Numb

er of

Ses

sions

Deac

tivate

d

MS sess

Deac

Ms

Nr tspscApnSuccDeactivateSessionsMs

Activ

ation

Succ

ess R

ateDy

nami

c PDP

sess

Act

DynS

R

% 100 * tspscApnSuccActivateSessionsDyn // tspscApnAttActivateSessionsDyn

Numb

er of

Sess

ions

Activ

ated

Dyna

mic P

DP

sess

ActD

yn

Nr tspscApnSuccActivateSessionsDyn

Activ

ation

Succ

ess

Rate

actS

R

% 100 * tspscApnSuccActivateSessions // tspscApnAttActivateSessions

Numb

er of

Sess

ions

Activ

ated

sess

Act

Nr tspscApnSuccActivateSessions

Objec

t

<Access Point Name>

Tim

e

HH:mm

ISP

Sess

ion

Analy

sis R

epor

t <AG

GREG

ATIO

N>St

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 98: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

98 E200301-01-214-V10.0I-01

4.2.3 ATM MP on SGSN

4.2.3.1 MP Overload

4.2.3.1.1 SGSN Uplink MP Overload Report

Report Name: SGSN Uplink MP Overload Report

Report Short Name: SgsnUpMpOvloadReport

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: For GPRS the report provides detailed information regarding the overloadhandling on the LLC layer. The results include the number of rejected PDPcontext activations due to overload control (only for PO2.0 on), the number ofdiscarded packets due to overload control, and, transmission rates for LLCand SNDCP packets.The SNDCP packets transmitted represent the chargeable service provided tothe subscribers. The SNDCP packets are transmitted uplink to the serviceaccess point defined by the PDP context received.LLC frames are transparent to the BSS and they transmit to the peer layer inthe MS the user data compressed received from the SNDCP layer SAP alongwith signalling data for GMM functions. LLC frames have variable numbers ofbytes and their transmission rates represent the efficiency in the use of theradio interface.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

"TEVL"

Input Parameters:

(e) EXCH SGSN Symbolic Name

Measurements: sgsnFAIcurrentDatasgsnLLCcurrentDatasgsnOverloadPdShCurrentDatasgsnSNDCPcurrentData

Remarks: None.

Page 99: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-0199

Layout:

RejectedPDP Context

ActivationHigh Priority

PO2

rejActHiPrio

Nr

rejActPdpCtxH

ighPriority

RejectedPDP Context

ActivationLow Priority

PO2

rejActLoPrio

Nr

rejActPdpCtxLow

Priority

Rejected IuEstablishment

RequestsPO2

rejIuEstReq

Nr

rejIuEstablishmentR

equestDiscarded

SMS

disSms

NrdisSm

sMO

DiscardedData Packets

(SMS andSNDCP)

disDataPkts

Nr

disDataPacketsU

L

DiscardedMM

Requests

disMmReq

Nr

disMM

Request

Discarded traffic

ErrorLLC

Frames

llcErrFrm

Nr

llcErrorFramesR

eceivedUL

LLCSuccess

Rate

llcSR

%

100 * llcFramesR

eceivedSucc // llcFram

esReceived

Handled LLCFrames with

Success

llcFrmSuc

Nr

llcFramesR

eceivedSucc

Incoming Traffic

Handled LLCFrames

llcFrm

Nr

llcFramesR

eceived

Object

<SGSN

Nam

e>

Time

HH

:mm

SGSN Uplink MP Overload Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 100: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

100 E200301-01-214-V10.0I-01

Layout (cont):

SNDC

PSu

cces

s Rate

sndc

pSR

%

100 * (uplinkNpduNackPktsSucc ++ uplinkNpduAckPktsSucc) /

/ (uplinkNpduNackPkts ++ uplinkNpduAckPkts)

User

Data

Thro

ughp

ut

sndc

pThp

ut

kbps 8 * (uplinkNpduNackOctets +

+ uplinkNpduAckOctets) / (1000 * T)Ha

ndled

SND

CPPa

ckets

with

Succ

ess

sndc

pPkt

sSuc

Nr uplinkNpduNackPktsSucc ++ uplinkNpduAckPktsSucc

Hand

led S

NDCP

Pack

ets

sndc

pPkt

s

Nr uplinkNpduNackPkts ++ uplinkNpduAckPkts

SMS

MOAt

tempts

smsM

oAtt

Nr attSmsMO[2G+3G]

PDP

Conte

xtMo

difica

tion A

ttemp

tsMS

-Initia

tedPO

2

mod

AttM

s

Nr attModPdpContextMs[2G+3G]

Outgo

ing tr

affic

PDP

Conte

xtAc

tivati

onAt

tempts

actA

tt

Nr PO1: attActPdpContextPO2: attActPdpContext[2G+3G]

Objec

t

<SGSN Name>

Tim

e

HH:mm

SGSN

Upl

ink M

P Ov

erlo

ad R

epor

t <AG

GREG

ATIO

N>St

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 101: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 101

4.2.3.1.2 SGSN Downlink MP Overload Report

Report Name: SGSN Downlink MP Overload Report

Report Short Name: SgsnDownMpOvloadReport

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: The purpose of this report is similar to the previous except it analysis the loadon the downlink direction per SGSN.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

"TEVL"

Input Parameters:

(e) EXCH SGSN Symbolic Name

Measurements: sgsnFAIcurrentDatasgsnLLCcurrentDatasgsnSNDCPcurrentData

Remarks: None.

Page 102: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

102E200301-01-214-V10.0I-01

Layout:

LLC SuccessRate

llcSR

%

100 * llcFramesSentSucc /

/ llcFramesSent

HandledLLC Frameswith Success

llcFrmSuc

Nr

llcFramesSentSucc

Outgoing Traffic

HandledLLC Frames

llcFrm

Nr

llcFramesSent

DiscardedData Packets

(SMS and SNDCP)PO2

disDataPkts

Nr

disDataPacketsD

L

Discarded Traffic

Error LLCFrames

llcErrFrm

Nr

llcErrorFramesR

eceivedDL

HandledSNDCPPackets

sndcpPkts

Nr

downlinkN

pduNackPkts +

+ downlinkN

pduAckPkts

SMS MOSuccesses

smsMoS

Nr

PO2: succSm

sMO

[2G+3G

]PO

1: succSmsM

O

Incoming Traffic

User DataThroughput

thput

kbps

8 * (downlinkN

pduNackO

ctets ++ dow

nlinkNpduAckO

ctets) / (1000*T)

Object

<SGSN

Nam

e>

Time

HH

:mm

SGSN Downlink MP Overload Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 103: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 103

4.2.3.2 SGSN Licence Violations Report

Report Name: SGSN Licence Violations Report

Report Short Name: SgsnLicViolReport

Target Groups: Network Operation, Network Optimisation, Marketing & Management.

Description: This report monitors violation of the parameters of the SGSN licenses, namelynumber of attached subscribers, number of attached camel subscribers,number of simultaneous sessions and throughput. Warnings related withthese license violations are also provided via QoS Alarms on the SGSN. ForGPRS, it provides information on user data throughput in each direction(uplink and downlink).

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""DTOT""TEVL"

Input Parameters:

(e) EXCH SGSN Simbolic Name

Measurements: sgsn2gGMMAFcurrentData and/or sgsn3gGMMAFcurrentDatasgsn2gSMcurrentData and/or sgsn3gSMcurrentDatasgsnFAIcurrentDatasgsnSNDCPcurrentData

Remarks: None.

Page 104: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

104E200301-01-214-V10.0I-01

Layout:

Number ofDiscarded

Packets dueto Buffer

Congestion

disPktsBufCong

Nr

nbrDisD

ataPackets

LimitThroughputViolations

thputVio

Nr

licViolCongestionC

ontrol

Downlink

thputDl

Mbps

8 * (downlinkN

pduNackO

ctets ++ dow

nlinkNpduAckO

ctets) / (1000000 * T)

User Data Throughput(Only 2G)

Uplink

thputUl

Mbps

8 * (uplinkNpduN

ackOctets +

+ uplinkNpduAckO

ctets) / (1000000 * T)

Limit ofSimultaneous

SessionsViolations

sessVio

Nr

licViolActPDPC

ontext

MeanNumber ofSessions

avgSess

Nr

PO1: m

eanActPDPC

ontext[2G + 3G

]PO

2: meanActPD

PContextH

ighPriority[2G + 3G

] ++ m

eanActPDPC

ontextLowPriority[2G

+ 3G]

PO2

Nr

licViolCam

el2G + licViolC

amel3G

Limit of AttachedCamel Subscribers

violations

(only 2G)PO1

atchCamVio

Nr

licViolCam

el

PO2

Nr

meanN

brCam

elSub[2G + 3G

]

Mean Numberof Attached

Camel Subscribers

(only 2G)PO1

avgAttchCamSubs

Nr

meanN

brCam

elSub

Limit ofAttached

Subscribersviolations

atchVio

Nr

licViolSubscribers

MeanNumber

of AttachedSubscribers

avgAtchSubs

Nr

meanN

brOfAttachedSub[2G

+ 3G]

Object

<SGSN

Nam

e>

Time

HH

:mm

SGSN Licence Violations Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 105: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 105

4.2.3.3 Reports with 2nd and 3rd Generation variants

4.2.3.3.1 SGSN Session Analys is Report

Report Name: SGSN Session Analysis Report

Report Short Name: SgsnSessionReport

Target Groups: Network Operation, Network Optimisation.

Description: The report provides detailed analysis of the session handling per SGSN. Itsupplies statistics regarding session activation, update, modification, averageduration, etc. Separated indicators depending on session priority are providedfor equipment versions greater than PO1.0.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""DTOT""TEVL"

(e) xG "2G""3G"

Depending on the para-meter, a report will beproduced either with thecounters fromsgsn2gSMcurrentData orwith the counters fromsgsn3gSMcurrentData.Furthermore, columnsdescribed in the headerfield with "Only 2G" arefiltered if option 3G isselected.

Input Parameters:

(f) EXCH SGSN SymbolicName

Measurements: sgsn2gSMcurrentData or sgsn3gSMcurrentData

Remarks: None.

Page 106: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

106 E200301-01-214-V10.0I-01

Layout:

SGSN

deac

SRSg

sn % 100 * succDeactPdpContextSgsn // attDeactPdpContextSgsn

Deac

tivati

on S

ucce

ss R

ate

MS

deac

SRMs % 100 * succDeactPdpContextMs / attDeactPdpContextMs

SGSN

sess

Deac

Sgsn Nr succDeactPdpContextSgsn

Numb

er of

Ses

sions

Deac

tivate

d

MS

sess

Deac

Ms Nr succDeactPdpContextMs

Activ

ation

Succ

ess R

ateDy

nami

c PDP

sess

Act

DynS

R

% 100 * succActPdpContextDyn / attActPdpContextDyn

Numb

er of

Sess

ions

Activ

ated

Dyna

mic P

DP

sess

ActD

yn

Nr succActPdpContextDyn

Activ

ation

Succ

ess

Rate

actS

R

%

PO1: 100 * succActPdpContext / attActPdpContextPO2: 100 * (succActPdpContextHighPriority +

+ succActPdpContextLowPriority) / attActPdpContext

PO1

sess

Act

Nr succActPdpContext

Low

PO2

sess

Act

LoPr

io

Nr succActPdpContextLowPriority

Numb

er of

Ses

sions

Acti

vated

High

PO2

sess

Act

HiPr

io

Nr succActPdpContextHighPriority

Objec

t

<SGSN Name>

Tim

e

HH:mm

SGSN

<xG>

Ses

sion

Analy

sis R

epor

t <AG

GREG

ATIO

N>St

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 107: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 107

Layout (cont):

Mean

Ses

sion

Dura

tion

avgS

essD

ur

sec PO1: T * meanActPdpContext / succActPdpContext

PO2: totalPdpContextDuration // (succActPdpContextHigh + succActPdpContextLow)

PO1

avgS

ess

Nr meanActPdpContext

Low

PO2

avgS

ess

LoPr

io

Nr meanActPdpContextLowPriority

Mean

Num

ber o

f Ses

sions

High

PO2

avgS

ess

HiPr

io

Nr meanActPdpContextHighPriority

Upda

tes pe

rSe

ssion

PO2

updS

ess

Nr

(succUpdPdpContextSgsn ++ succUpdPdpContextGgsn) /

/ (succActPdpContextHighPriority ++ succActPdpContextLowPriority)

Upda

teSu

cces

sRa

tePO

2

updS

r

%

100 * (succUpdPdpContextSgsn ++ succUpdPdpContextGgsn) // (attUpdPdpContextGgsn ++ attUpdPdpContextSgsn)

Numb

er of

Sess

ions

Upda

tedPO

2

sess

Upd

Nr succUpdPdpContextSgsn + succUpdPdpContextGgsn

Modif

icatio

nspe

r Ses

sion

mod

Sess

Nr

PO1: succModPdpContext / succActPdpContextPO2: 100 * (succModPdpContextSgsn +

+ succModPdpContextMs) // (succActPdpContextHighPriority ++ succActPdpContextLowPriority)

Modif

icatio

nSu

cces

sRa

te

mod

SR %

PO1: 100 * succModPdpContext / attModPdpContextPO2: 100 * (succModPdpContextSgsn +

+ succModPdpContextMs) / (attModPdpContextMs ++ attModPdpContextSgsn)

Numb

er of

Sess

ions

Modif

ied

sess

Mod

Nr

PO1: succModPdpContextPO2: succModPdpContextSgsn +

+ succModPdpContextMs

Objec

t

<SGSN Name>

Tim

e

HH:mm

SGSN

<xG>

Ses

sion

Analy

sis R

epor

t AGG

REGA

TION

Star

t Date

: <ST

ART_

DATE

>En

d Date

: <EN

D_DA

TE>

Date YYYY-MM-DD

Page 108: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

108 E200301-01-214-V10.0I-01

4.2.3.3.2 SGSN Performance Analysis Report

Report Name: SGSN Performance Analysis Report

Report Short Name: SgsnPerfReport

Target Groups: Network Operation, Network Optimisation Network Planning.

Description: Provided by this report is a general overview of the SGSN performance. Thisincludes information on: number of subscribers in SGSN area, average numberof sessions, short message service, routing area updates and attach anddetach success rates.For GPRS it also provides information regarding average throughput, numberof kbytes per session along with paging success rate.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""DTOT""TEVL"

(e) xG "2G""3G"

Depending on the parame-ter, a report will be producedeither with the counters fromsgsn2gGMMAFcurrentData,sgsn2gSMcurrentData andra2gGMMAFcurrentData orwith the counters fromsgsn3gGMMAFcurrentData,sgsn3gSMcurrentData andra3gGMMAFcurrentData.Furthermore, columnsdescribed in the header fieldwith "Only 2G" are filtered ifoption 3G is selected.

Input Parameters:

(f) EXCH SGSN SymbolicName

Measurements: ra2gGMMAFcurrentData or ra3gGMMAFcurrentDatara2gGMMTFcurrentDataraPagingCurrentData (only PO2.0)sgsn2gGMMAFcurrentData or sgsn3gGMMAFcurrentDatasgsn2gSMcurrentData or sgsn3gSMcurrentDatasgsn2gSMScurrentData (if <xG>=2G) or sgsn3gSMScurrentData (only PO2.0)sgsnGMMAFcurrentDatasgsnGMMTFcurrentData (if <xG>=2G)sgsnSNDCPcurrentData (if <xG>=2G)

Remarks: None.

Page 109: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 109

Layout:

PO2 If <xG> = 2G Then 100 * succPsPagingProc2G /

/ attPsPagingProc2G Else 100 * succPsPagingProc3G / attPsPagingProc3G

Pagin

g Suc

cess

Rate

PO1

(only

2G) pa

gSR

%

100 * succPsPaging / attPsPagingDo

wnlin

k

kbyS

essD

l

kbyt

e

PO1: (downlinkNpduAckOctets ++ downlinkNpduNackOctets) *

* meanActPDPContext / (1000 * succActPdpContext)PO2: (downlinkNpduAckOctets +

+ downlinkNpduNackOctets) ** (meanActPDPContextHighPriority ++ meanActPDPContextLowPriority) /

/ (1000 * (succActPdpContextHighPriority ++ succActPdpContextLowPriority)

Aver

age N

umbe

r of k

bytes

per S

essio

n(O

nly 2G

)

Uplin

k

kbyS

essU

l

kbyt

e

PO1: (uplinkNpduAckOctets+ uplinkNpduNackOctets) ** meanActPDPContext / (1000 * succActPdpContext)

PO2: (uplinkNpduAckOctets+ uplinkNpduNackOctets) ** (meanActPDPContextHighPriority ++ meanActPDPContextLowPriority) /

/ (1000 * (succActPdpContextHighPriority +succActPdpContextLowPriority)

Down

link

thpu

tSub

Read

yDl

bps 8 * (downlinkNpduAckOctets +

+ downlinkNpduNackOctets) / (T * nbrSubReady)

Aver

age T

hrou

ghpu

t per

Sub

scrib

erRe

ady (

Only

2G)

Uplin

k

thpu

tSub

Read

yUl

bps 8 * (uplinkNpduAckOctets + uplinkNpduNackOctets) /

/ (T*nbrSubReady)

Mean

Numb

erof

Sess

ions

avgS

ess

Nr

PO1: meanActPDPContextPO2: meanActPDPContextHighPriority +

meanActPDPContextLowPriority

Total

Num

ber

of Su

bscri

bers

Loca

ted in

SGSN

Are

a

subs Nr meanNbrHomeSub + meanNbrVistingNatSub +

+ meanNbrVisitingForeign

Objec

t

<SGSN Name>

Tim

e

HH:mm

SGSN

<xG>

Per

form

ance

Ana

lysis

Repo

rt AG

GREG

ATIO

NSt

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 110: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

110 E200301-01-214-V10.0I-01

Layout (cont):

Sess

ionAc

tivati

onSu

cces

s Rate

actS

R

%

PO1: 100 * succActPdpContext / attActPdpContextPO2: 100 * (succActPdpContextHigh +

+ succActPdpContextLow) / attActPdpContext

Resp

onse

from

HLR

Succ

ess R

ate

hlrR

esSR

%

PO1: 100 * succReqAuthSetsHlr / attReqAuthSetsHlrPO2: 100 * (succReqAuthSetsHlrV1 +

+ succReqAuthSetsHlrV3) / (attReqAuthSetsHlrV1 ++ attReqAuthSetsHlrV3)

Routi

ng A

rea

Upda

teSu

cces

s Rate

raUp

dSR

%100 * (succInterSgsnRaUpdate +

+ succIntraSgsnRaUpdate) / (attInterSgsnRaUpdate + + attIntraSgsnRaUpdate)

PO2

SMS

MT S

ucce

ss R

ate

PO1

(only

2G)

smsM

tSR

% 100 * succSmsMt / attSmsMt

PO2

SMS

MO S

ucce

ss R

ate

PO1

(only

2G)

smsM

oSR

% 100 * succSmsMo / attSmsMo

Detac

h Fro

mMS

Rate

msD

tchR

ate

% 100 * attGprsDetachMs / (attGprsDetachMs ++ attGprsDetachSgsn)

Attac

hSu

cces

s Rate

atch

SR % 100 * succGprsAttach / attGprsAttach

Objec

t

<SGSN Name>

Tim

e

HH:mm

SGSN

<xG>

Per

form

ance

Ana

lysis

Repo

rt AG

GREG

ATIO

NSt

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 111: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 111

4.2.3.3.3 SGSN Nominal Load Report

Report Name: SGSN Nominal Load Report

Report Short Name: SgsnNomLoadReport

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: This report will provide information concerning subscriber behaviour in order toobtain a realistic traffic model.This report will provide a set of statistic results to be compared with the nodespecifications. The information included is related to both number of subscri-bers and the processes run by the Node such as attach, detach, routing areaupdates, paging, activation and deactivation. Furthermore for GPRS the reportwill supply information regarding the amount of handled packages and userdata throughput in both directions.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""DTOT""TEVL"

(e) xG "2G""3G"

Depending on the parame-ter, a report will be produ-ced either with the countersfromsgsn2gGMMAFcurrentData,sgsn2gSMScurrentData,ra2gGMMTFcurrentData,sgsn2gSMcurrentData andra2gGMMAFcurrentData orwith the counters fromsgsn3gGMMAFcurrentData,sgsn3gSMcurrentData andra3gGMMAFcurrentData.Furthermore, columns des-cribed in the header fieldwith "Only 2G" are filtered ifoption 3G is selected.

Input Parameters:

(f) EXCH SGSN SymbolicName

Measurements: ra2gGMMAFcurrentData or ra3gGMMAFcurrentDatara2gGMMTFcurrentData (if <xG>=2G)raPagingCurrentData (only PO2.0)sgsn2gGMMAFcurrentData or sgsn3gGMMAFcurrentDatasgsn2gSMcurrentData or sgsn3gSMcurrentDatasgsn2gSMScurrentData (if <xG>=2G) or sgsn3gSMScurrentData (only PO2.0)sgsnSNDCPcurrentData (if <xG>=2G)

Remarks: None.

Page 112: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

112 E200301-01-214-V10.0I-01

Layout:

Mean

Num

ber

of Se

ssion

s

avgS

ess

Nr

PO1: meanActPDPContextPO2: meanActPDPContextHigh +

+ meanActPDPContextLow

PO2 If <xG> = 2G Then attPsPagingProc2G / T

Else attPsPagingProc3G / T

PS P

aging

Pro

cedu

res

per S

econ

d

PO1

(only

2G) ps

Page

Sec

Nr

attPsPaging / T

Routi

ng A

rea

Upda

tes pe

rSe

cond

raUp

dSec

Nr (attInterSgsnRaUpdate ++ attIntraSgsnRaUpdate) / T

Attac

h and

Deta

chpr

oced

ures

per S

econ

d

atch

Dtch

Sec

Nr (attGprsAttach + attGprsDetachMs ++ attGprsDetachSgsn) / T

Mean

Num

ber

of At

tache

dSu

bscri

bers

avgA

tchS

ubs

Nr meanNbrOfAttachedSub

Total

Num

ber

of Su

bscri

bers

Loca

ted in

SGSN

Are

a

subs Nr

meanNbrHomeSub ++ meanNbrVistingNatSub ++ meanNbrVisitingForeign

Objec

t

<SGSN Name>

Tim

e

HH:mm

SGSN

<xG>

Nom

inal

Load

Rep

ort A

GGRE

GATI

ONSt

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 113: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 113

Layout (cont):

Down

link

thpu

tDl

kbps 8 * (DownlinkNpduNackOctets +

+ DownlinkNpduAckOctets) / (1000*T)

User

Data

Thr

ough

put

(Only

2G)

Down

link

thpu

tUl

kbps 8 * (uplinkNpduNackOctets +

+ uplinkNpduAckOctets) / (1000*T)

Down

link

sndc

pPkt

sSec

Dl

Pkt/s (downlinkNpduNackPkts +

+ downlinkNpduAckPkts) / T

Hand

led S

NDCP

Pac

kets

per S

econ

d(O

nly 2G

)

Uplin

k

sndc

pPkt

sSec

Ul

Pkt/s (uplinkNpduNackPkts + uplinkNpduAckPkts) / T

PO2

SMS

per S

econ

d

PO1

(only

2G) sm

sSec

Nr (attSmsMt + attSmsMo) / T

GGSN

initia

tedDe

activ

ation

spe

r Sec

ond

ggsn

Deac

Sec

Nr attDeactPdpContextGgsn / T

Sess

ion A

ctiva

tion

Deac

tivati

ons

Proc

edur

es pe

rSe

cond

actD

eacS

ec

Nr (attActPdpContext + attDeactPdpContextMs ++ attDeactPdpContextGgsn) / T

Objec

t

<SGSN Name>

Tim

e

HH:mm

SGSN

<xG>

Nom

inal

Load

Rep

ort A

GGRE

GATI

ONSt

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 114: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

114 E200301-01-214-V10.0I-01

4.2.3.4 Cisco based GGSN Reports

4.2.3.4.1 APN Performance Report

Report Name: APN Performance Report

Report Short Name: Apn_perf_rep

Target Groups: Network Operation

Description: This report presents APN performance data.

Name Possible Values Remarks

(g) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(h) START_DATE Any date(i) END_DATE Any date(j) AGGREGATION "TEVL"

"DTOT"

Input Parameters:

(k) APN APN NameMeasurements: C_GPRSAPN

Remarks: None

Layout Content:

Report presents:

MSACTIVPDPS

SUCCACTIVPDPS ACTIVEPDPS UPSTRMTRAFFVO

L UPSTRMTRAFFVOL

Nr Nr Nr bps bps

4.2.3.4.2 GGSN Performance Report

Report Name: GGSN Performance Report

Report Short Name: ggsn_perf_rep

Target Groups: Network Operation

Description: This report presents GGSN performance data.

Name Possible Values Remarks

(l) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(m) START_DATE Any date

Input Parameters:

(n) END_DATE Any date

Page 115: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 115

(o) AGGREGATION "TEVL""DTOT"

(p) GGSN GGSN NameMeasurements: C_GPRSGGSN

Remarks: None

Layout Content:

Report presents:

TOTCREATPDPS

TOTDELETEPDPS

ACTIVEREJPDPS OUTRESPDPS TOTPPPPDCR

EATTOTPPPPDPDELE

T

Nr Nr Nr Nr Nr Nr

4.2.3.4.3 GTP Throughput Report

Report Name: GTP Throughput Report

Report Short Name: Gtp_throughput_rep

Target Groups: Network Operation

Description: This report presents GTP performance data.

Name Possible Values Remarks

(q) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(r) START_DATE Any date(s) END_DATE Any date(t) AGGREGATION "TEVL"

"DTOT"

Input Parameters:

(u) GGSN GGSN NameMeasurements: C_GPRSGTP

Remarks: None

Layout Content:

Report presents:

SENTGPDUS RECVGPDUS SENTSIGMSGS RECVDSIGMSGS

Pkt/s Pkt/s Nr Nr

Page 116: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

116 E200301-01-214-V10.0I-01

4.3 VAS

The MSP – Mobile Smart Proxy is currently the only platform supported.

Page 117: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 117

4.3.1 MSP

Report Name: MSP Service Layer Report

Report Short Name: msp_service_layer_rep

Target Groups: Network Operation

Description: This report presents all the MSP Service Layer performance data.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "TEVL"

"DTOT"

Input Parameters:

(e) MSP NE NameMeasurements: MSPSERVICE

Remarks: none

Layout:

MSC Service Layer ReportStart Date: <START_DATE>

End Date: <END_DATE>

CCGNotDefinedByUserAgent

RetrievalAGFromAuthServerFailed

AGNotInIPRanges

PerformanceClassNotDefined

UnknownAGFromAuthServerRetrieved

Nr Nr Nr Nr NrDate Time Object

YYYY

-MM

-DD

HH

:mm

NE

Nam

e

Num

ber o

f tim

es th

e C

CG

has

not

bee

nde

fined

Num

ber o

f tim

es th

e re

triev

al o

f an

AG fr

omth

e Au

then

ticat

ion

Serv

er h

as fa

iled

Num

ber o

f tim

es th

e AG

is n

ot w

ithin

IPra

nges

Num

ber o

f tim

es th

e th

e Pe

rform

ance

Cla

ssis

not

def

ined

for o

ne U

ser

Num

ber o

f tim

es a

n un

know

n AG

is re

triev

edfro

m th

e Au

then

ticat

ion

Serv

er

Page 118: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

118 E200301-01-214-V10.0I-01

5 Radio Access Netw ork

5.1 GERAN

Page 119: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 119

5.1.1 Base Station Overview Report

Report Name: Base Station Overview Report

Report Short Name: BssOverviewReport

Target Groups: Network Operation, Network Optimisation, Marketing & Management.

Description: This report aims to provide overview information about the load situation andsuccess rates of basic protocol procedures of the GSM Cells both for TCHand for SDCCH channels.Basic problems related to load can be immediately detected as well as indica-tions leading to other more complex problems that need further proceedings,examples of these problems are interference and bad coverage.Additional handover information can also be provided by adding to this reportthe handover information from the "Base Station Handover Analysis Report"in order to give more details about any problems affecting the performance ofthe network.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous days countingfrom today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"DTOT""TEVL"

(e) CH "ALL""TCH""SDCCH"

Case "TCH" only theTCH table will be provi-ded, case "SDCCH" onlythe SDCCH table will beprovided; otherwise, bothwill be provided

(f) BSC BSC Symbolic Name(g) BTS Cell Symbolic Name

Input Parameters:

(h) BSC_TOTALS """BSC Totals"

The results will be pre-sented per BSC, if "BSCTotals" report is chosen.

Page 120: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

120 E200301-01-214-V10.0I-01

Measurements: From SCANBTSOHON functional group:ATINBHDONRUNINHDSUINBHDO

All scanners from SCANBTS functional group, with the following exceptions:AMRCHDISMBTCHAMRMEITCHIBNAVTCHSDNDFTCHSDNNNOTNCHNTCHSDCMTASSATVSTASSUCVSTNMSCNCLTNSUDHSC

Remarks: This report is also available in SPOTS V10 for BR5.5 and BR5.0, but in thatcase, since NRDEFTCH counters are only available from BR6.0 on, the maxi-mum values for NAVTCH counters are used instead as approximation.Furthermore SDCCH HO related indicators aren't available for BR5.5.

Page 121: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-01121

Layout:

TCHMean Holding

Time

tch MHT

sec

>40

<TCH

MH

TDR

>

TCHTrafficCarried

tch Traf Carr

Erl

<TCH

TrafCarrD

R>

TCH Loss Rate(Loss Systems)

tch Loss Rate LS

%

<1

100 * <TCH

LossRateD

R>

Mean Waiting Time

avg Wait T

sec

<5

MD

UR

TCR

Q[1..4] / 4

Load

TCH Loss Rate(Waiting Systems)

tch Loss Rate WS

%

<1

100 * <TCH

LossRateW

SDR

>

TCHEfficiency

tch Eff

%

>98

100 * <TCH

EffDR

>

TCH

Number OfDefined TCH

def Tch

Nr

NR

DEFTC

H[2,5,8,11]

CT

Cell Type (0 - N

ormal; 1 - C

oncentric; 2 - Extended)

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Overview Report <BSC_TOTALS> <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 122: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

122 E200301-01-214-V10.0I-01

Layout (cont):

TCH

Drop

s Per

Erlan

g Hou

r

tch

D Er

lh

Nr <4 <TCHDropErlh>

Mean

Tim

eBe

twee

n TCH

Drop

avg

T Be

tw T

ch D

min >60 <MTBTCHDrop>Dr

op

TCH

Drop

Rate

tch

DR % <2 100 * <TCHDropRate>

Impe

rativ

e HO

Rate

Imp

HO R

ate

%

100 * (ATINHIAC[1,2] + ATINHIRC[1..4] ++ ATINBHDO[1..4,11..14,…,311..314]) /

/ (<IntraCellHOAtt> + <InterCellHOAtt> ++ <InterBSCHOAtt>)

HO D

rop

Rate

HO D

R

% <1.5 100 * (<IntraCellHODrop> + UNIHIRLC[1] +

+ <InterBSCHODrop>) / (<IntraCellHOAtt> ++ <InterCellHOAtt> + <InterBSCHOAtt>)Ha

ndov

er

HO S

ucce

ssRa

te

HO S

R

% >90 100 * (<IntraCellHOSucc> + <InterCellHOSucc> +

+ <InterBSCHOSucc>]) / (<IntraCellHOAtt> ++ <InterCellHOAtt> + <InterBSCHOAtt>)

Numb

er of

Succ

essfu

lDi

recte

d Retr

ies

Succ

Dir

Retry

Nr <NoSuccDirectedRetry>

Numb

er O

fSu

cces

sful C

allSe

tup A

ttemp

ts

CS S

ucc

N <CSSucc>

TCH

Call S

etup

Call S

etup

Succ

ess R

ate

CS S

R

% >95 100 * <CSSuccRateBSS>

Objec

t

<Cell Symbolic Name>

Tim

e

HH:mm

Base

Sta

tion

Over

view

Repo

rt <B

SC_T

OTAL

S> <A

GGRE

GATI

ON>

Star

t Date

: <ST

ART_

DATE

>En

d Date

: <EN

D_DA

TE>

Date YYYY-MM-DD

Page 123: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-01123

Layout (cont):

SDCCHDrops Per

Erlang Hour

sdcchD Erlh

Nr

<1

<SDC

CH

DropErlh>

Mean TimeBetweenSDCCH

Drop

avgTBetwSdcchD

Min

>500

<MTBSD

CC

HD

rop>Drop

SDCCHDrop Rate

sdcchDR

%

<0.1

100 * <SDC

CH

DropR

ate>

InternalSDCCH

HOSuccess

Rate

sdcchIntHO SR

%

>60

100 * (SISHIN

TR[1] +

+ SISHIN

TE[1]) / (AISHIN

TR[1] +

+ AISHIN

TE[1])

SDCCHActivation

FailureRate

sdcchAct FR

%100 * (<Im

mAssLoss> - ATSD

CM

BS[1])/ /(<Im

mAssAtt> - ATSD

CM

BS[1])

Number OfSuccessfulImmediate

Assignments

immAssSucc

Nr

<Imm

AssSucc>

Immediate Assignment

ImmediateAssignment

SuccessRate

immAssSR

%

>98

100 * <Imm

AssSuccRate>

SDCCHMean

HoldingTime

sdcchMHT

sec

<6

<SDC

CH

MH

T>

SDCCHTrafficCarried

sdcchTrafCarr

Erl

<SDC

CH

TrafCarr>

Load

SDCCHLoss Rate

sdcchLossRate

%

<0.1

100 * <SDC

CH

LossRate>

SDCCHEfficiency

sdcch Eff

%

>98

100 * <SDC

CH

Eff>

SDCCH

Number ofDefinedSDCCH

defSdcch

Nr

ND

ESDC

CH

[2]

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Overview Report <BSC_TOTALS> <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 124: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

124 E200301-01-214-V10.0I-01

5.1.2 Base Station Ranking Report

Report Name: Base Station Ranking Report

Report Short Name: BssRankingReport

Target Groups: Network Operation, Network Optimisation, Marketing & Management.

Description: The purpose of this report is to evaluate and compare cell performances usinga unique indicator, namely "Quality Index". This indicator aggregates the keyperformance indicators that give information about the resource usage andabout the subscriber perception related to the quality of a network. Thoseindicators are:• Call Setup Success Rate• TCH Drops per Erlanghour• Probability of Bad Speech Quality• TCH Traffic LoadEach indicator has a weight factor (see Input Parameters) which is a numberbetween 0 and 10 that enables the operator to set the relative relevance ofeach indicator in is concept of cell quality.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

"DTOT"(e) BSC BSC Symbolic Name(f) BTS Cell Symbolic Name(g) WCSF Weight of Call Setup

Failure. Any value ≥0and ≤10

Default = 2.5

(h) WTD Weight of TCH Drop.Any value ≥0 and ≤10

Default = 2.5

(i) WBSQ Weight of Bad SpeechQuality. Any value ≥0and ≤10

Default = 2.5

Input Parameters:

(j) WTRW Weight of TCHResource Waste. Anyvalue ≥0 and ≤10

Default = 2.5

Page 125: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 125

Measurements: From SCANBTS functional group:ATIMASCAATSDCMBSMEBUSTCHNACSUCPRNMSGDISQNRDEFTCHNRFLSDCCNRFLTCHNSUCCHPCSINTHINTSUIMASCATACCBPROTASSATTTASSFAILTASSSUCCUNIHIALCUNIHIRLC

From SCANBTSOHON functional group:ATINBHDONRUNINHDSUINBHDO

From SCANTRX functional groupCFERRXQU

Remarks: The indicator <QualityLink2FER> should always be aggregated to present thedaily values.

Page 126: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

126E200301-01-214-V10.0I-01

Layout:

Base Station Ranking Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Quality IndexFailedCalls

Call SetupSuccess

Rate BSS

TCH Dropsper

Erlanghour

Probabilityof BadSpeechQuality

TCHTrafficLoad

quality IndexFailed Calls

CSSR BSStch Drop Erlh

quality Link2FER

tch TrafLoad

Nr%

Nr%

%

DateTim

eObject

CT

<2>95

<4<5

YYYY-MM-DD

HH:mm

<CellSymbolic Name>

Cell Type (0 - Normal; 1 - Concentric; 2 - Extended)

WCSF * <CSSucc> * (1 - <CSSuccRateBSS>) ^ 2 ++ WTD * <TCHDrop> * <TCHDropErlh> * 90 / T +

+ WBSQ * SUCTCHSE[1,2] * 0.4 * <QualityLink2FER> ^ 2 ++ WTRW * (If <TCHTrafLoad> < 0.05 Then 0.95 Else (1 -

- <TCHTrafLoad>)) * <TCHTrafCarrDR> // (<TCHTrafLoad> * 50)

<CSSucc> * (1 - <CSSuccRateBSS>) + <TCHDrop>

100 * <CSSuccRateBSS>

<TCHDropErlh>

100 * <QualityLink2FER>

<TCHTrafLoad> = 100 * <TCHTrafCarrDR> / NRDEFTCH[2,5,8,11]

Page 127: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 127

5.1.3 Base Station Grade Of Service Report

Report Name: Base Station Grade Of Service Report

Report Short Name: BssGosReport

Target Groups: Network Operation, Network Optimisation, Network Planning.

Description: This report provides detailed information about the load situation of the GSMCells both for TCH and for SDCCH channels. In addition it provides alsoimportant results for channel resource optimisation like for instance thenumber of defined SDCCH channels, SDCCH traffic carried, the number ofdefined TCH channels and the TCH traffic carried. It also provides severalcalculations using traffic theory formulas both for Waiting systems (Erlang Cformula) and for Loss systems (Erlang B formula).The indicators "TCH ErlangB Blocking Rate", "Delta TCH", "Probability ofWaiting More than WT sec" and "Mean Queue Length for Delta=0", useErlang formulas which only produce accurate results case the statisticalbehaviour of the traffic measured is similar to the statistical behaviourassumed on the traffic theory behind those formulas.The Erlang B formula assumes that the density of traffic during the busy houris fairly constant and the number of calls which exist simultaneously onlyfluctuates statistical around its average value. The question "how far are theseassumptions from the real life traffic?" can be answered after comparing theindicators "TCH Loss Rate (in Loss Systems)" and "TCH Blocking Rate", ifthese indicators present similar values then the assumptions can beconsidered a good approximation to the real traffic.The Erlang C formula makes use of the same assumptions of Erlang Bformula plus three other assumptions: the holding times are exponentiallydistributed, the traffic offered is lower than the number of serving trunks andall call which have to wait always wait until they can be handled. Of coursethis is not real life behaviour of the traffic, but in this case it can also be testedhow far these assumptions are from the truth. So, if the "TCH Loss Rate(Waiting Systems)" is greater than zero the system being analysed is not aproper waiting system and maybe the buffer holding the calls hasn't enoughcapacity or the queue is to long so the capacity will have to be expanded. Bycomparing the "Mean Waiting Time" and "Mean Waiting Time Expected", itcan be stated, case these indicators present similar values, that the two otherassumptions are also realistic. "Delta TCH" provides to the user the difference between the number of TCHdefined in the BTS and the number of TCH required to handle the trafficoffered with upper limits for loss and/or for waiting probabilities defined by theuser. It is calculated both for Waiting systems (Erlang C formula) and for Losssystems (Erlang B formula), and furthermore, it results are provided for allbasic types of channel, namely TCH Full Rate, TCH Half Rate and SDCCH.

Page 128: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

128 E200301-01-214-V10.0I-01

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous days countingfrom today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH TC Peak""SPBH Daily Peaks"

(e) CH "ALL""TCH""SDCCH"

Case "TCH" only the TCHtable will be provided,case "SDCCH" only theSDCCH table will beprovided, otherwise, bothwill be provided

(f) HALF_RATE "YES""NO"

Case "YES", also theindicators variants relatedwith Half Rate channelswill be included in thereport, otherwise, just theFull Rate indicators andthe ones independentfrom the type of channelare displayed.

(g) WS_LS_OR_BOTH "BOTH""WS""LS"

Case "LS", load indica-tors specified only for losssystems will be provided.Case "WS", load indica-tors specified only forwaiting systems will beprovided. Otherwise bothwill be presented on thereports.

(h) BSC BSC Symbolic Name(i) BTS Cell Symbolic Name(j) ADMISSIBLE_LOSS Max TCH Loss Rate Default = 1 %(k) SDCCH_

ADMISSIBLE_LOSSMax SDCCH LossRate

Default = 0.1 %

(l) WT Admissible waitingtime in seconds forcalls in queue.

Default = 10 secThis value is a configura-tion parameter of BSCbut for the report anyother value can beassumed

Input Parameters:

(m) WP Max Probability ofWaiting More thanWT sec

Default = 4 %

Page 129: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 129

Measurements: From SCANBTS functional group:AALTCHTIASDCALTIATCHSMBSATSDCMBSATTCHSEIMBUSYSDCMDURTCRQMEBUSTCHMTCHBUTIMTCHQLENNASUSDPENATTSDPENAVSDCCHNAVTCHNDESDCCHNMSGDISQNRDEFTCHSUCTCHSETASSATTTASSFAILTASSSUCCTNTCHCL

Remarks: This report is also available in SPOTS V10 for BR5.5 and BR5.0, but in thatcase, since NRDEFTCH counters are only available from BR6.0 on, the maxi-mum values for NAVTCH counters are used instead as approximation.

Page 130: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

130E200301-01-214-V10.0I-01

Layout:

DeltaTCH Half

LS deltaTch H

Nr

>0

NR

DEFTC

H[5,11] -

- ErlangB(<TCH

TrafCarrH

R>, LO

SS)

DeltaTCH Full

LS deltaTch F

Nr

>0

NR

DEFTC

H[2,8] -

- ErlangB(<TCH

TrafCarrFR

>, LOSS)

TCH ErlangBBlocking Rate

Half

LS tch ErlBBlock Rate H

%

<1

100 * <TCH

ErlBlockRateH

R>

TCH ErlangBBlocking Rate

Full

LS tch ErlBBlock Rate F

%

<1

100 * <TCH

ErlBlockRateFR

>

TCH TrafficOffered

LS tch TrafOff DR

Erl

<TCH

TrafOffD

R>

TCH TrafficUtilisation

LS tchTraf Util

%

100 * <TCH

TrafUtilD

R>

Loss Systems

TCHLoss Rate

LS tchLoss Rate

%

<1

100 * <TCH

LossRateD

R>

TCHTrafficCarried

tchTraf Carr

Erl

<TCH

TrafCarrD

R>

TCHBlocking

Rate

tch BlockRate

%

<1

100 * <TCH

BlockRateD

R>

NumberOf

DefinedTCH Half

defTch H

Nr

NR

DEFTC

H[5,11]

TCH

NumberOf

DefinedTCH Full

defTch F

Nr

NR

DEFTC

H[2,8]

CT

Cell Type (0 - N

ormal; 1 - C

oncentric; 2 - Extended)

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Grade Of Service Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 131: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 131

Layout (cont):

Mean

Que

ueLe

ngth

forDe

lta=0

WS

mea

nQue

Len

ifDelt

a=0

Nr ErlangC(AH, NF, <TCHMHTFR>) ++ ErlangC(AF, NH, <TCHMHTHR>)

Delta

TCH

Half

WS

Delta

H

Nr >0

NRDEFTCH[5,11] - NHNH = ErlangC(WT, WP, AH, <TCHMHTHR>)

Delta

TCH

Full

WS

Delta

F

Nr >0

NRDEFTCH[2,8] - NFNF = ErlangC(WT, WP, AF, <TCHMHTFR>)

Prob

abilit

y of

Wait

ing M

ore

than W

Tse

c Half

Wait

Prob

forW

T H

% <10 100 *

* ErlangC(WT, NRDEFTCH[5,11], AH,<TCHMHTHR>)

Prob

abilit

y of

Wait

ing M

ore

than W

Tse

c Full

Wait

Prob

forW

T F

% <10 100 *

* ErlangC(WT, NRDEFTCH[2,8], AF,<TCHMHTFR>)

Mean

Wait

ingTim

eEx

pecte

d

mea

n W

aitT

Expc

sec

<5

(<TCHMHTHR> / (NRDEFTCH[5,11] - AH) ++ <TCHMHTFR> / (NRDEFTCH[2,8] - AF)) / 2

Mean

Wait

ingTim

e

mea

nW

aitT

sec

<5 MDURTCRQ[1..4] / 4

TCH

Traff

icOf

fered

WSt

chTr

afOf

f

Erl AH + AF

AH = <TCHTrafCarrHR> / (1-<TCHLossRateWSHR>)AF = <TCHTrafCarrFR> / (1-<TCHLossRateWSFR>)

TCH

Traff

icUt

ilisati

on

WSt

chTr

afUt

il

% 100 * <TCHTrafUtilDR (8; ErlangC)>

Mean

Que

ueLe

ngth

WSM

eaQu

eLen

Nr MTCHQLEN[1,2]

TCH

Wait

ing S

ystem

s

TCH

Loss

Rate

WSt

chLo

ssRa

te

% <1 100 * <TCHLossRateWSDR>

Objec

t

<Cell Symbolic Name>

Tim

e

HH:mm

Base

Sta

tion

Grad

e Of S

ervic

e Rep

ort <

AGGR

EGAT

ION>

Star

t Date

: <ST

ART_

DATE

>En

d Date

: <EN

D_DA

TE>

Date YYYY-MM-DD

Page 132: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

132E200301-01-214-V10.0I-01

Layout (cont):

SDCCHMean

Holding Time

sdcch MHT

Sec

<6

<SDC

CH

MH

T>

DeltaSDCCH

sdcch delta

Nr

>0

ND

ESDC

CH

[3] -- ErlangB(<SD

CC

HTrafC

arr>, SDLO

SS)SDCCHErlangB

Blocking Rate

sdcch ErlBlock Rate

%

<0.1

100 * <SDC

CH

ErlBlockRate>

SDCCHTrafficOffered

sdcchTraf Off

Erl

<SDC

CH

TrafOff>

SDCCHTraffic

Utilisation

sdcchTraf Util

%

100 * <SDC

CH

TrafUtil>

SDCCHTrafficCarried

sdcchTraf Carr

Erl

<SDC

CH

TrafCarr>

SDCCHLoss Rate

sdcchLoss Rate

%

<0.1

100 * <SDC

CH

LossRate>

SDCCHBlocking

Rate

sdcchBlock Rate

%

<0.1

100 * <SDC

CH

BlockRate>

SDCCHEfficiency

sdcch Eff

%

>98

100 * <SDC

CH

Eff>

SDCCH

Number OfDefinedSDCCH

def Sdcch

Nr

ND

ESDC

CH

[2]

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Grade Of Service Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 133: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 133

5.1.4 Base Station Call Setup Analysis Report

Report Name: Base Station Call Setup Analysis Report

Report Short Name: BssCallSetupReport

Target Groups: Network Operation, Network Optimisation.

Description: The purpose of this report is to detect GSM Cells with problems in the callsetup procedure and provide detailed information about reasons for call setupfailure.When analysing the indicators "Number of Call Setup Attempts", "Call SetupSuccess Rate", "Number Of Call Setup Failures" and "Percentage of CallSetup Failure Rate due to SSS Procedure Failure". Please note thatAuthentication, Identity, Ciphering and MSC failures are also counted inthese formulas although they are not related to the BSS. User Releasebefore assignment of a TCH is also included in "SSS Procedure Failure"formula. SMS Mobile Terminating (MTC – answer to paging) are also countedin "SSS Procedure Failure" formula due to the fact that the PAGINGRESPONSE is included in the Establishment INDICATION Message anddoes not allow any distinction between MTC and SMS Mobile Terminating.Thus, to conclude about the BSS performance in terms of Call SetupSuccess Rate, it is better to use the indicator "Call Setup Success Rate BSS"instead of "Call Setup Success Rate" because the first one don't takes intoaccount SSS procedure failures unless their were caused by SDCCH drops.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"SPBH Daily Peaks""DTOT""TEVL"

(e) BSC BSC Symbolic Name

Input Parameters:

(f) BTS Cell Symbolic Name

Measurements: From SCANBTS functional group:ATIMASCAATSDCMBSNACSUCPRNMSGDISQNRFLSDCCNSUCCHPCSINTHINTSUIMASCATACCBPROTASSATTTASSFAILTASSSUCC

From SCANBTSOHON functional group:SUINBHDO

Remarks: This report is also available in SPOTS V10 for BR5.5 and BR5.0.

Page 134: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

134E200301-01-214-V10.0I-01

Layout:

QueuingFailures

CS F DistQue Fail

%

<1

100 * <CSFailQ

ueFail> // <C

SFail>

Assign.Failures

with otherReasons

CS F DistAss Fail

Other

%

100 * <CSFailAssFailO

ther> // <C

SFail>

Assign.Failuresby Msg.

CS FDist

Ass FailBy Msg

%

100 * <CSFailAssFailbyM

ess> / / <C

SFail>TCHLoss

CS FDistTchLoss

%

<1

100 * <CSFailTC

HLoss> /

/ <CSFail>

SSSProcedure

Failure

CS FDistSSS

Proc Fail

%

100 * <CSFailSSSProcFail> // <C

SFail>

SDCCHDrops

CS FDist

SdcchDrop

%100 * <C

SFailSDC

CH

Drop> /

/ <CSFail>

ImmediateAssign.

without MSSeizure

CS FDistImm

Ass NoSeiz

%

100 * <CSFailIm

mAssN

oSeiz> / / <C

SFail>

AGCHLoss

CS FDist

AgchLoss

%

100 * <CSFailAG

CH

Loss> // <C

SFail>

Percentage of Call Setup Failure Rate due to

ImmediateAssign.Losses

CS F DistImm Ass

Loss

%

100 * <CSFailIm

mAssLoss> /

/ <CSFail>

Numberof CallSetup

Failures

CS Fail

Nr

<CSFail>

Numberof Succ.

CallSetups

CS Suc

Nr

<CSSucc>

Numberof CallSetup

Attempts

CS Att

Nr

<CSAtt>

CallSetupSucc.RateBSS

CS SRBss

%

>95

100 * <CSSuccR

ateBSS>

CallSetup

SuccessRate

CS SR

%

100 * <CSSuccR

ate>

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Call Setup Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 135: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 135

5.1.5 Base Station Traffic F low Report

Report Name: Base Station Traffic Flow Report

Report Short Name: BssTraFlowReport

Target Groups: Network Optimisation; Network Planning.

Description: This report provides the number of calls and the number of intracell hand-overs between different cell areas (if extended or concentric cells), the num-ber of internal intercell handovers and the number of external intercell hand-overs. The following schema represents the information provided:

Target Cells connected to a different BSC

Target Cells connected to the same BSC

B C

D

EOrigin Cell (Observed Cell)

F G

Inner Area /Near Area

Complete Area /Far Area

A

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

"TEVL""DTOT"

(e) BSC BSC Symbolic Name

Input Parameters:

(f) BTS Cell Symbolic Name

Measurements: From SCANBTS functional group:NSUCCHPCSINTHINTSINTHITASUCTCHSETASSSUCC

From SCANBTSOHON functional group:SUINBHDO

From SCANBTSIHO functional group:SININIRH

Remarks: This report is also available in SPOTS V10 for BR5.5 and BR5.0.

Page 136: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

136E200301-01-214-V10.0I-01

Layout:

G

Intracell HOComp. to Inner Areaor Near to Far Area

itrHoCIOrNFSuc

Nr

SINTH

ITA[4] + SINTH

ITA[6]

F

Intracell HOInner to Comp. Areaor Far to Near Area

itrHoICOrFNSuc

Nr

SINTH

ITA[3] + SINTH

ITA[5]

E

Intercell Inter BSCOutgoing HO

extOutHoSuc

Nr

<InterBSCH

OSucc>

C

Intercell Intra BSCOutgoing HO

iteOutHoSuc

Nr

<InterCellH

OSucc>

B

Intercell Intra BSCIncoming HO

iteIncHoSuc

Nr

SININ

IRH

[all]

A

Call Setups

CSSucc

Nr

<CSSucc>

CT

Cell Type (0 - N

ormal; 1 - C

oncentric; 2 - Extended)

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Traffic Flow Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 137: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 137

5.1.6 Base Station Traffic Report

Report Name: Base Station Traffic Report

Report Short Name: BssTrafficReport

Target Groups: Network Planning; Network Optimisation

Description: The report provides the values for Configured TCH, Available TCH and TCHTraffic Carried, separate indicators distinguish between different channel ty-pes (i.e. TCH Full Rate and TCH Half Rate) and between channels dedicatedto different cell areas (i.e. inner area and complete area if concentric cell, or,single timeslot and double timeslot if extended cell). It also provides other loadindicators like blocking rate and traffic offered.The results are produced according to the “SPBH TC Peak“ criterion.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) BSC BSC Symbolic Name

Input Parameters:

(e) BTS Cell Symbolic Name

Measurements: From SCANBTS functional group:AALTCHTIATCHSMBSATTCHSEIMEBUSTCHNAVTCHNRDEFTCH

Remarks: This report is also available in SPOTS V10 for BR5.5 and BR5.0, but in thatcase, since NRDEFTCH counters are only available from BR6.0 on, the maxi-mum values for NAVTCH counters are used instead as approximation.

Page 138: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

138E200301-01-214-V10.0I-01

Layout:

Traffic’sThroughput forHR Inner Area

(SingleTimeslot)tch Traf

Carr H IS

Erl

TC_SPBH

(MEBU

STCH

[2])

Traffic’sThroughput forHR channels

tch TrafCarr H

Erl

TC_SPBH

(MEBU

STCH

[2,4])Traffic’s

Throughput forFR Complete

(DoubleTimeslot)

tch TrafCarr F CD

Erl

TC_SPBH

(MEBU

STCH

[3])

Traffic’sThroughput forFR Inner Area

(SingleTimeslot)tch TrafCarr F IS

Erl

TC_SPBH

(MEBU

STCH

[1])

TCH Traffic Carried

Traffic’sThroughput forFR channels

tch TrafCarr F

Erl

TC_SPBH

(MEBU

STCH

[1,3])

CompleteArea

(DoubleTimeslot)

tchAvail CD

Nr

TC_SPBH

(NAVTC

H[9,12])

InnerArea

(SingleTimeslot)

tchAvail IS

Nr

TC_SPBH

(NAVTC

H[3,6])

TCH Available

NormalCells

(Total)

tchAvail

Nr

TC_SPBH

(NAVTC

H[3,6,9,12])

HR

tchConsH

Nr

TC_SPBH

(NR

DEFTC

H[6,12])

FR

tchConsF

Nr

TC_SPBH

(NR

DEFTC

H[3,9])

TCH Consistency

NormalCells

(Total)

tchCons

Nr

TC_SPBH

(NR

DEFTC

H[3,9] + 0.5 *

* NR

DEFTC

H[6,12])

CT

Cell Type (0 - N

ormal; 1 - C

oncentric; 2 - Extended)

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Traffic ReportStart Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 139: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-01139

Layout (cont):

Mean TimeCongestion

Rate(A_SPBH)

Mean TCongRate A_SPBH

%

A_SPBH(100 * <TC

HBlockR

ateDR

>)

TCHBlocking

Probability

tchBlock Prob

%

TC_SPBH

(100 * <TCH

BlockRateD

R>)

TCH Blockingprobability

usingErlangB

(A_SPBH)

tchErlB BlockProb A_SPBH

%

A_SPBH(100 * <TC

HErlBlockR

ateDR

>)

TCH Blockingprobability

usingErlangB

tchErlBBlock Prob

%

TC_SPBH

(100 * <TCH

ErlBlockRateD

R>)

TCHTrafficOffered

tchTrafOff

Erl

TC_SPBH

(<TCH

TrafOffD

R>)

Max Valueof traffics

peak(MAX_SPBH)

tchTrafCarr

Erl

MAX_SPBH

(MEBU

STCH

[1..4])

MeanPeak

(A_SPBH)

tchTrafCarr

Erl

A_SPBH(M

EBUSTC

H[1..4])

CompleteArea

(DoubleTimeslot)

tchTrafCarr CD

Erl

TC_SPBH

(MEBU

STCH

[3,4])

InnerArea

(SingleTimeslot)

tchTrafCarr IS

Erl

TC_SPBH

(MEBU

STCH

[1,2])

NormalCells

(Total)

tchTrafCarr

Erl

TC_SPBH

(MEBU

STCH

[1..4])

TCH Traffic Carried

Traffic’sThroughput forHR Complete

(DoubleTimeslot)

tchTrafCarr H CD

Erl

TC_SPBH

(MEBU

STCH

[4])

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Traffic ReportStart Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 140: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

140 E200301-01-214-V10.0I-01

5.1.7 Base Station Synthes is Report

Report Name: Base Station Synthesis Report

Report Short Name: BssSynthesisReport

Target Groups: Network Operation, Network Optimisation.

Description: This report aims to provide overview information about the load situation anddistribution for distinct cell areas, and basic protocol procedures of the GSMCells both for TCH and for SDCCH channels.The results are produced according to the “DTOT” criterion except for "TCHthroughput in the busy hour" related indicators for which “SPBH Max Peak”criterion is applied.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous days countingfrom today.

(b) START_DATE Any date(c) END_DATE Any date(d) BSC BSC Symbolic Name

Input Parameters:

(e) BTS Cell Symbolic Name

Measurements: From SCANBTSOHON functional group:ATINBHDONRUNINHDSUINBHDO

All scanners from SCANBTS functional group, with the following exceptions:AMRCHDISMBTCHAMRNAVTCHSDNDFTCHSDNNNOTNCHNTCHSDCMTASSATVSTASSUCVSTNMSCNCLTNSUDHSC

Remarks: This report is also available in SPOTS V10 for BR5.5 and BR5.0, but in thatcase, since NRDEFTCH counters are only available from BR6.0 on, the maxi-mum values for NAVTCH counters are used instead as approximation.

Page 141: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-01141

Layout:

ImmediateAssignmentwithout MSseizure rate

imm AssNo

Seiz Rate

%

>98

100 * <Imm

AssNoSeizR

ate>

AGCHLossRate

agchLossRate

%

100 * <AGC

HLossR

ate>SDCCHChannel

ActivationFailureRate

sdcch ChAct FR

%

100 * (<Imm

AssLoss> - ATSDC

MBS[1]) /

/ (<Imm

AssAtt> - ATSDC

MBS[1])

SDCCHLossRate

sdcchLossRate

%

<0.1

100 * <SDC

CH

LossRate>

SDCCHEfficiency

sdcch Eff

%

100 * <SDC

CH

Eff>

Inter cell +intra cell +inter BSC

outgoing HOsuccessful

rate

ho SR

%

100 * (<InterCellH

OSucc> + <InterBSC

HO

Succ>) // (<InterC

ellHO

Att> + <InterBSCH

OAtt>)

TCHdisconnection

rate onnormal

releasedcalls

call DR

%

100 * <CallD

ropRate>

SuccessfulAssignmentprobability

succ AssProb

%

100 * <SuccAssProb>

TCH noblocking

probabilityon

user side

tch NoBlock

%

100 * <TchNoBlock>

Successfulsignalling

proceduresrate

succ SigProc Rate

%

100 * <SuccSigProcRate>

SDCCH no

blockingprobability

sdcchNo Block

%

100 * <SDC

CH

NoBlock>

MobileNetworkAccess

probability

MNAP

%

>95

100 * <NetAccProb>

CT

Cell Type (0 - N

ormal; 1 - C

oncentric; 2 - Extended)

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Synthesis ReportStart Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 142: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

142E200301-01-214-V10.0I-01

Layout (cont):

CompleteArea orDouble

Timeslot

tchTrafCarrSpbhCD

Erl

SPBH(M

EBUSTC

H[3,4])

InnerArea orSingle

Timeslot

tchTrafCarrSpbhIS

Erl

SPBH(M

EBUSTC

H[1,2])

TCH throughput in the busy hour

NormalCells or

Total

tch TrafCarrSpbh

Erl

SPBH(M

EBUSTC

H[1..4])

CompleteArea orDouble

Timeslot

tch TrafCarr CD

Erl

MEBU

STCH

[3,4]

InnerArea orSingle

Timeslot

tch TrafCarr IS

Erl

MEBU

STCH

[1,2]

TCH Traffic Carried

NormalCells or

Total

tchTrafCarr

Erl

MEBU

STCH

[1..4]

TCHLossRate

tchLossRate

%

<1

100 * <TCH

LossRate>

CompleteArea orDouble

Timeslot

tchEff CD

%

100 * (NAVTC

H[9] + 0.5 * N

AVTCH

[12]) // (N

RD

EFTCH

[9] + 0.5 * NR

DEFTC

H[12])

InnerArea orSingle

Timeslot

tchEff IS

%

100 * (NAVTC

H[3] + 0.5 * N

AVTCH

[6]) // (N

RD

EFTCH

[3] + 0.5 * NR

DEFTC

H[6])

TCH efficiency

NormalCells or

Total

tchEff DR

%

100 * <TCH

EffDR

>

SDCCHDropRate

related toCall

Setups

sdcchDrop Rate

%

<0.1

100 * <SDC

CH

DropR

ate>

SDCCHTrafficCarried

sdcchTrafCarr

Erl

<SDC

CH

TrafCarr>

Immediateassignment

FailureProbability

imm AssFail Prob

%

100 * (<Imm

AssAtt> - <Imm

AssLoss> -- <Im

mAssSucc>) / (<Im

mAssAtt> - <Im

mAssLoss>)

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Synthesis ReportStart Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 143: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-01143

Layout (cont):

Idlechannels

percent. ininterference

band 5

if BandRate 5

%

100 * <IfBandRate[5]>

Idlechannels

percent. ininterference

band 4

if BandRate 4

%

100 * <IfBandRate[4]>

Idlechannels

percent. ininterference

band 3

if BandRate 3

%

100 * <IfBandRate[3]>

Idlechannels

percent. ininterference

band 2

if BandRate 2

%

100 * <IfBandRate[2]>

Idlechannels

percent. ininterference

band 1

if BandRate 1

%

100 * <IfBandRate[1]>

ImperativeHo

percentage

impHO Perc

%

100 * <ImpO

utgHO

Rate>

Inter cell +intra + inter BSC

outgoing HOfailures with

loss ofconnection rate

ho DR

%

100 * (UN

IHIR

LC[1] + <InterBSC

HO

Drop>) /

/ (<InterCellH

OAtt> + <InterBSC

HO

Att>)

Inter cell +intra + inter BSC

outgoing HOfailures without

loss ofconnection rate

ho FR

%

100 * (<InterCellH

OFail> + <InterBSC

HO

Fail>) // (<InterC

ellHO

Att> + <InterBSCH

OAtt>)

TCH lossesdue to radiolink failureper hour of

conversation

tchDrop Erlh

Nr

<4

<TCH

DropErlh>

TCH radio linkfailures rate to

the totalnumber of

TCHconnection

tchDrop Rate

%

<2

100 * <TCH

DropR

ate>

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Synthesis ReportStart Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 144: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

144 E200301-01-214-V10.0I-01

5.1.8 Base Station Handover Overview Report

Report Name: Base Station Handover Overview Report

Report Short Name: BssHoOverviewReport

Target Groups: Network Operation, Network Optimisation.

Description: The purpose of this report is to detect GSM Cells with problems in the Hand-over procedure. Separated Performance Indicators for each handover typeare presented (i.e. Intra Cell HO, Outgoing Internal HO, Outgoing ExternalHO, Outgoing SDCCH HO, Incoming Internal HO, Incoming External HO).It also allows to detect missing neighbourhood relationships by analysing theindicator "Inter Cell Handover indication Success Rate"

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

"DTOT""TEVL"

(e) BSC BSC Symbolic Name

Input Parameters:

(f) BTS Cell Symbolic Name

Measurements: From SCANBTS functional group:AISHINTRAISHINTEAOINTESHATINHIACATINHIRCSINTHINTSINTHITASISHINTESISHINTRSOINTESH

From SCANBTSOHON functional group:ATINBHDOSUINBHDO

From SCANBTSIHO functional group:AININIRHSININIRH

Remarks: This report is also available in SPOTS V10 for BR5.5 and BR5.0, but in thatcase, SDCCH HO related indicators and the HO Indication Rejection Ratearen't available.

Page 145: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 145

Layout:

itr H

o SR

% >90 <IntraCellHOSuccRate>

Hand

over

itr H

o At

t

Nr <IntraCellHOAtt>

itr S

dcch

Ho

SR

% >70 <IntraCellSDHOSuccRate>

Numb

er of

Atte

mpts

and S

ucce

ss R

ate fo

r Intr

a Cell

SDCC

H Ha

ndov

er

itr S

dcch

Ho

Att

Nr AISHINTR[1]

Hand

over

Indic

ation

Rejec

tion R

ate

ho In

d Re

j Rat

e

% <5 100 * <HOIndRejRate>

Hand

over

Suc

cess

Rate

Rank

ing

ho S

R Ra

nk

% >90

(<IntraCellHOAtt> ** <IntraCellHOSuccRate> + <InterCellHOAtt> ** <InterCellHOSuccRate> + <InterBSCHOAtt> *

* <InterBSCHOSuccRate>) / ( <IntraCellHOAtt> ++ <InterBSCHOAtt> + <InterCellHOAtt>)

CT Cell Type (0 - Normal; 1 - Concentric; 2 - Extended)

Objec

t

<Cell Symbolic Name>

Tim

e

HH:mm

Base

Sta

tion

Hand

over

Ove

rview

Rep

ort <

AGGR

EGAT

ION>

Star

t Date

: <ST

ART_

DATE

>En

d Date

: <EN

D_DA

TE>

Date YYYY-MM-DD

Page 146: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

146E200301-01-214-V10.0I-01

Layout (cont):

extHo SR

%

>90

<InterBSCH

OSuccR

ate>

Outgoing Handover

extHo Att

Nr

<InterBSCH

OAtt>

ext SdcchHo SR

%

>50

<InterBSCSD

HO

SuccRate>

Number of Attempts and Success Rate for Inter Cell Inter BSC

SDCCH Handover

ext SdcchHo Att

Nr

AOIN

TESH[1]

iteHo SR

%

>90

<InterCellH

OSuccR

ate>

Outgoing Handover

iteHo Att

Nr

<InterCellH

OAtt>

ite IncHo SR

%

>90

<InterCellIncH

OSuccR

ate>

Incoming Handover

ite IncHo Att

Nr

AININ

IRH

[1..11]

ite SdcchHo SR

%

>70

<InterCellSD

HO

SuccRate>

Number of Attempts and Success Rate for Inter Cell Intra BSC

SDCCH Handover

ite SdcchHo Att

Nr

AISHIN

TE[1]

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station Handover Overview Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 147: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 147

5.1.9 Base Station Handover Analysis Report

Report Name: Base Station Handover Analysis Report

Report Short Name: BssHoReport

Target Groups: Network Optimisation.

Description: This report provides the number of HOs per cause and some important perfor-mance indicators to correlate with the HO information. This simple informationtable should be enough for an optimiser with reasonable background know-ledge to detect many problems affecting the network performance. For instan-ce, he will be able to identify cells which have: an unusual high number ofhandover attempts, cells with high number of quality handover attempts due tointerference problems, cells with a high number of dropped calls due to HOdrops, unbalanced links, etc.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous days countingfrom today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "DTOT"(e) BSC BSC Symbolic Name

Input Parameters:

(f) BTS Cell Symbolic Name

Measurements: From SCANBTS functional group:ATINHIACATINHIRCNRFLTCHSUCTCHSETASSFAILUNIHIRLCUNIHIALC

From SCANBTSOHON functional group:ATINBHDONRUNINHDSUINBHDO

Remarks: This report is also available in SPOTS V10 for BR5.5 and BR5.0. Please notethat the list of HO causes is shorter in BR5.5.

Page 148: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

148 E200301-01-214-V10.0I-01

Layout:

Sum

ite Sum Nr <InterCellHOAtt> + <InterBSCHOAtt>

FP ite FP Nr ATINHIRC[11]

FU ite FU Nr ATINHIRC[10] + ATINBHDO[10,21,32,..,351]

TRAF ite Traf Nr ATINHIRC[9] + ATINBHDO[9,20,31,..,350]

MF ite MF Nr ATINHIRC[8] + ATINBHDO[8,19,30,..,349]

DR ite DR Nr ATINHIRC[7] + ATINBHDO[7,18,29,..,348]

BC ite BC Nr ATINHIRC[6] + ATINBHDO[6,17,28,..,347]

DIST ite Dis

t

Nr ATINHIRC[5] + ATINBHDO[5,16,27,..,346]

DLS

ite DS Nr ATINHIRC[4] + ATINBHDO[4,15,26,..,345]

ULS

ite US Nr ATINHIRC[3]> + ATINBHDO[3,14,25,..,344]

DLQ

ite DQ Nr ATINHIRC[2] + ATINBHDO[2,13,24,..,343

Attem

pted I

nter C

ell H

ando

ver (

Intra

BSC

+ In

ter B

SC) p

er C

ause

ULQ

ite UQ Nr ATINHIRC[1] + ATINBHDO[1,12,23,..,342]

Sum itr Sum Nr <IntraCellHOAtt>

MF itr MF Nr ATINHIAC[7]

CTIA

orFT

FN itrC

I OrF

N

Nr ATINHIAC[4] + ATINHIAC[6]

ITCA

orNT

FA itrIC

OrN

F

Nr ATINHIAC[3] + ATINHIAC[5]

DLQ

itr DQ Nr ATINHIAC[2]

Attem

pted I

ntra C

ell H

ando

vers

per C

ause

ULQ

itr UQ Nr ATINHIAC[1]

Objec

t

<Cell Symbolic Name>

Tim

e

HH:mm

Base

Sta

tion

Hand

over

Ana

lysis

Repo

rtSt

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 149: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 149

Layout (cont):

TCH

Drop

Rate

tch

DR

% 100 * <TCHDrop> / SUCTCHSE[1,2]

HO D

rop R

ate

ho D

R

% 100 *<TCHDropHO>) / (ATINHIRC[1..11] ++ <IntraCellHOAtt> + <InterBSCHOAtt>)

Inter

Cell

HO D

rop R

ate

ite H

o D

R

% 100 * (UNIHIRLC[1] + <InterBSCHODrop>) // (<InterCellHOAtt> + <InterBSCHOAtt>)

Intra

Cell

HO D

rop R

ate

itr H

o D

R

% 100 * <IntraCellHODropRate>

Inter

Cell

HO

Drop

s

ite H

o D

rop

Nr UNIHIRLC[1] + <InterBSCHODrop>

Intra

Cell

HO

Drop

s

itr H

o D

rop

Nr <IntraCellHODrop>

TCH

Drop

s

tch

Dro

p

Nr <TCHDrop>

TCH

Conn

ectio

ns

tch

Con

n

Nr SUCTCHSE[1,2]

Objec

t

<Cell Symbolic Name>

Tim

e

HH:mm

Base

Sta

tion

Hand

over

Ana

lysis

Repo

rtSt

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 150: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

150 E200301-01-214-V10.0I-01

5.1.10 Base Station Outgoing Handover Report

Report Name: Base Station Outgoing Handover Report

Report Short Name: BssOutgoingHoReport

Target Groups: Network Operation, Network Optimisation.

Description: The purpose of this report is to monitor the handover success rate betweenOrigin- and Target Cell.Furthermore, this report will help to identify Origin/Target cell pairs withunusual behaviour such as:− No handover attempts between neighbour cells;− High number of handover attempts indicating overlapping of cell coverage

areas with subsequent ping-pong handovers;− High number of handover attempts between two neighbours, but zero

successful handover;− High number of handover attempts between two neighbours, but low

handover success rate;− Target cells, for which it is in general difficult to make an handover into.The distribution between handover causes will also be analysed for each pair.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

"DTOT""TEVL"

(e) BSC BSC Symbolic Name

Input Parameters:

(f) BTS Cell Symbolic Name

Measurements: From SCANBTSOHON functional group:ATINBHDONRUNINHDSUINBHDO

From SCANBTSOHOI functional group:AOUINIRHSOUINIRHUNINHOIE

Remarks: None.

Page 151: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 151

Layout:

HO D

rop R

ate

ho D

R

% <3 100 * (<InterCellHODropRate> + <InterBSCHODropRate>)

HO S

ucce

ss R

ate

ho S

R

% >90 100 * (<InterCellHOSuccRate> + <InterBSCHOSuccRate>)

Delta

delta Nr (<InterCellHOAtt> + <InterBSCHOAtt>) -

- (<InterCellHOSucc> + <InterBSCHOSucc>)

Numb

er of

HO

Succ

ess

ho S

uc

Nr <InterCellHOSucc> + <InterBSCHOSucc>

Numb

er of

HO

Attem

pts

ho A

tt

Nr <5 <InterCellHOAtt> + <InterBSCHOAtt>

Case

Exte

rnal

Cell -

"0"

else i

f Inter

nal C

ell -

"1"

Inte

rnal

Nr If <InterCellHOAtt> > 0 Then "1"Else If <InterBSCHOAtt>> 0 Then "0"

Objec

t

<Origin Cell Symbolic Name>:<Target Cell Symbolic Name>

Tim

e

HH:mm

Base

Sta

tion

Outg

oing

Han

dove

r Rep

ort <

AGGR

EGAT

ION>

Star

t Date

: <ST

ART_

DATE

>En

d Date

: <EN

D_DA

TE>

Date YYYY-MM-DD

Page 152: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

152 E200301-01-214-V10.0I-01

Layout (cont):

Force

d due

toPr

eemp

tion

hoDi

stFP % 100 * (<InterCellHODist[11]> + <InterBSCHODist[10]>)

Fast

Uplin

k

hoDi

stFU % 100*(<InterCellHODist[10]> + <InterBSCHODist[9]>)

Traff

ic

hoDi

stTr

af

% 100 * (<InterCellHODist[9]>)

O&M

Force

d

hoDi

stMF % 100 * (<InterCellHODist[8]> + <InterBSCHODist[8]>)

Dire

cted

Retry ho

Dist

DR % 100 * (<InterCellHODist[7]> + <InterBSCHODist[7]>)

Bette

rCe

ll

hoDi

stBC % 100 * (<InterCellHODist[6]> + <InterBSCHODist[6]>)

Dista

nce

hoDi

stDi

st

% 100 * (<InterCellHODist[5]> + <InterBSCHODist[5]>)

DLSt

reng

th

hoDi

stDS % 100 * (<InterCellHODist[4]> + <InterBSCHODist[4]>)

ULSt

reng

th

hoDi

stUS % 100 * (<InterCellHODist[3]> + <InterBSCHODist[3]>)

DLQu

ality

hoDi

stDQ % 100 * (<InterCellHODist[2]> + <InterBSCHODist[2]>)

Hand

over

Dist

ributi

on

ULQu

ality

hoDi

stUQ % 100 * (<InterCellHODist[1]> + <InterBSCHODist[1]>)

Objec

t

<Origin Cell Symbolic Name>:<Target Cell Symbolic Name>

Tim

e

HH:mm

Base

Sta

tion

Outg

oing

Han

dove

r Rep

ort <

AGGR

EGAT

ION>

Star

t Date

: <ST

ART_

DATE

>En

d Date

: <EN

D_DA

TE>

Date YYYY-MM-DD

Page 153: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 153

5.1.11 Unbalanced Links Report

Report Name: Unbalanced Links Report

Report Short Name: UnbLinksReport

Target Groups: Network Optimisation, Network Planning

Description: The purpose of this report is to detect GSM Cells with unbalanced linksbetween uplink and downlink direction and identify the level differencebetween them.Unbalanced links might result in degraded network performance.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "TEVL"

"DTOT"(e) BSC BSC Symbolic Name

Input Parameters:

(f) BTS Cell Symbolic Name

Measurements: From SCANBTS functional groupATINHIR

From SCANBTSOHON functional group:ATINBHDO

From SCANCHAN functional group:PWRUPDW

Remarks: Power Control must be deactivated in order to get correct values for RxLevmeasurements.

Page 154: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

154 E200301-01-214-V10.0I-01

Layout:

Unbalanced Links Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

HandoverBalance Rate

Mean RxLevel Uplink

Mean RxLevel Downlink

Rx LevelBalance Rate

HOBalance Rate

meanRxLv UL

meanRxLv DL

RxLvBalance Rate

Nr Nr Nr Nr

Date Time Object

0.8 < 1.2 0.8 < 1.2

YYYY

-MM

-DD

HH

:mm

<Cel

l Sym

bolic

Nam

e>

100

* (AT

INH

IRC

[1,3

] + A

TIN

BHD

O[(1

+ 9

* i),

(3 +

9 *

i)]) /

/ (AO

UIN

IRH

[(2 +

10

* i),

(4 +

10

* i)]

+ AT

INH

IRC

[2,4

])

<Mea

nRxL

vUL>

<Mea

nRxL

vDL>

<Mea

nRxL

vUL>

/ <M

eanR

xLvD

L>

Page 155: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 155

5.1.12 Base Station GPRS Performance Report

Report Name: Base Station GPRS Performance Report

Report Short Name: BssGprsPerfReport

Target Groups: Network Optimisation, Network Planning, Marketing & Management.

Description: With this report, the performance of GPRS connections on GSM Cells isevaluated. It provides indicators that enable the identification of problemsrelated to channel capacity.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

"SPBH Max Peak""SPBH TC Peak""TEVL"

(e) BSC BSC Symbolic Name

Input Parameters:

(f) BTS Cell Symbolic Name

Measurements: All scanners from SCANBTSGPRS functional group.

Remarks: It would be important to add to the report the number of statically allocatedPDCH.This report is also available in SPOTS V10 for BR5.5.

Page 156: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

156E200301-01-214-V10.0I-01

Layout:

DownLinkRetransmission

Rate

DLRetrRate

%

100 * <DLR

etransRate>

UpLinkRetransmission

Rate

ULRetrRate

%

100 * <ULR

etransRate>

Mean ThroughputDownLink per

Configured PDCH

meanThputDLPdch

kbps<M

eanThputDLPD

CH

>

Mean ThroughputUpLink per

Configured PDCH

meanThputULPdch

kbps

<MeanThputU

LPDC

H>

Mean DataDownLink

Throughputon Air Interface

meanDataDLUm

kbps

<MeanD

ataDLU

m>

Mean DataUpLink

Throughputon Air Interface

meanDataULUm

kbps

<MeanD

ataULU

m>

Packet AccessRejections dueto Congestion

pAccRejCon

Nr

<PAccRejC

on>

Mean Numberof PDCH

DynamicallyConfigured

meanPdchConf

Nr

<MeanPD

CH

Conf>

CT

Cell Type (0 - N

ormal; 1 - C

oncentric; 2 - Extended)

Object

<Cell Sym

bolic Nam

e>

Time

HH

:mm

Base Station GPRS Performance Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 157: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 157

5.1.13 Base Station Interference Band Report

Report Name: Base Station Interference Band Report

Report Short Name: BssInterfBandReport

Target Groups: Network Optimisation

Description: This report provides the percentage of idle TCH in each interference band cal-culated from the total number of idle TCHs (it uses the Interference Band Rateon Idle TCH key performance indicator). The results are produced per cell.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

"DTOT""TEVL"

(e) BSC BSC Symbolic Name

Input Parameters:

(f) BTS Cell Symbolic Name

Measurements: From SCANBTS functional group:MEITCHIB

Remarks: This report is also available in SPOTS V10 for BR5.5 and BR5.0.

Layout:

Base Station Interference Band Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Interference Band Rate on Idle TCH

Band 1 Band 2 Band 3 Band 4 Band 5

ifBandRate1 ifBandRate2 ifBandRate3 ifBandRate4 ifBandRate5

% % % % %

Date Time Object

YYYY

-MM

-DD

HH

:mm

<Cel

l Sym

bolic

Nam

e>

100

* <IfB

andR

ate[

1]>

100

* <IfB

andR

ate[

2]>

100

* <IfB

andR

ate[

3]>

100

* <IfB

andR

ate[

4]>

100

* <IfB

andR

ate[

5]>

Page 158: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

158 E200301-01-214-V10.0I-01

5.1.14 TRX Level And Qualit y Report

Report Name: TRX Level and Quality Report

Report Short Name: TrxLevQualReport

Target Groups: Network Planning; Network Optimisation

Description: The report provides the mean RXLEV and RXQUAL on busy TCH. Both foruplink and downlink.It also provides the Level Band for which N% (with Ndefined by ) of themeasurements on busy channels registered a RXLEV in a lower Level Band.This information is directly related with the coverage probability because it canbe stated that 90% coverage probability was achieved (usual goal of networkplanning) if the result Level Band was found greater or equal to the Level Bandwhich includes the defined minimum acceptable RXLEV.Furthermore, the report also provides the Quality Band for which 90% of themeasurements on busy channels registered a RXQUAL in a lower Quality Band.Two indicators distinguish between uplink and downlink.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

"DTOT""TEVL"

(e) BSC BSC Symbolic Name(f) BTS Cell Symbolic Name(g) N_PERCENTILE_LV_DL Default = 10 %(h) N_PERCENTILE_LV_UL Default = 10 %(i) N_PERCENTILE_QU_DL Default = 90 %

Input Parameters:

(j) N_PERCENTILE_QU_UL Default = 90 %

Measurements: From SCANCHAN functional group:PWRUPDW

Remarks: None.

Page 159: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-01159

Layout:

Downlink

RxLevN Perc DL

Nr

>8

<RxLvN

PercentileDL>

RXLEV for N% Percentileon Busy TCH

Uplink

RxLevN Perc UL

Nr

>8

<RxLvN

PercentileUL>

Downlink

meanRxLv DL

Nr

<MeanR

xLvDL>

Mean RXLEV on Busy TCH

Uplink

meanRxLv UL

Nr

<MeanR

xLvUL>

Downlink

RxQual NPerc DL

Nr

<RxQ

uNPercentileD

L>

RXQUAL for N% Percentileon Busy TCH

Uplink

RxQual NPerc UL

Nr

<RxQ

uNPercentileU

L>

Downlink

mean RxQu DL

Nr

<MeanR

xQuD

L>

Mean RXQUAL on Busy TCH

Uplink

mean RxQu UL

Nr

<MeanR

xQuU

L>

Object

<Cell Sym

bolic>:<TRX Id>

Time

HH

:mm

TRX Level And Quality Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 160: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

160 E200301-01-214-V10.0I-01

5.1.15 Base Station Link Quality Report

Report Name: Base Station Link Quality Report

Report Short Name: BssLinkQualReport

Target Groups: Network Optimisation

Description: This report provides performance indicators that enable the detection ofinterference and subsequent bad call quality. Those indicators are:• "TCH Traffic Carried"

Hot spots (i.e. areas recording high traffic values) are naturally moreaffected by interference.

• "Intra Cell Quality Handover Attempts per Erlanghour"The amount of handovers due to quality for the same traffic volume isproportional to the amount of interference affecting that cell's channels.Thus, it is a good indicator to compare cells in terms of interference if theyare configured with equal thresholds for intra cell quality handover.

• "Intra Cell Handover Drops per Erlanghour"High values indicate that either the handover C/I threshold is set to low,or, the interference is seriously affecting that cell causing an abnormalincrease of intracell handover attempts. Moreover, no available betterchannel exist within that cell due to traffic overload or spreadoutinterference, and, in resume, the intracell handover feature is not solvingall interference problems.

• "Mean FER"High values for the Frame Erasure Rate result in bad speech quality, so, itis possible to compare the average speech quality between different cellsusing this indicator. Furthermore, knowing that it's mainly affected by cell'sperformance in terms of interference and coverage, the average FER isalso useful to detect interference and coverage related problems.

• "Quality Link for 2% FER"It's the amount of measurements that registered Frame Erasure Rateslower than 2% expressed in a percentage. This value should assumevalues greater than 90% and it gives an approximate number for theactual percentage of subscribers receiving a good speech quality.

• "High RXLEV Low RXQUAL Rate"This indicator provides the percentage of mobile reports that registered areceived bad quality and, simultaneously, a received high signal level.This combination happens as result of interference, thus, it is a reliableindicator to measure interference.

The evaluation of all these indicators in one single tabular report can give aclear picture for the localisation of interference related problems.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

"DTOT""TEVL"

(e) BSC BSC Symbolic Name

Input Parameters:

(f) BTS Cell Symbolic Name

Page 161: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 161

Measurements: From SCANBTS functional group:ATINHIACMEBUSTCHUNIHIALC

From SCANTRX functional group:CFERRXQUCRXLVQUU

Remarks: SCANTRX measurements can't both be collected simultaneously; so, therespective columns should present daily values.

Page 162: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

162E200301-01-214-V10.0I-01

Layout:

Downlink

high Lv LowQu Rate DL

%

100 * <HighLvLow

QuR

ateDL>

High RXLEV Low RXQUAL Rate

Uplink

high Lv LowQu Rate UL

%

100 * <HighLvLow

QuR

ateUL>

Quality Link for2% FER

quality Link2Fer

%

100 * <QualityLink2FER

>

Mean FERUplink

mean Fer UL

Nr

<MeanFER

UL>

Intra CellHandover Dropsper Erlanghour

itr HoDrop Erlh

Nr

UN

IHIALC

[1] // (T / 3600 * <TC

HTrafC

arrDR

>)

Downlink

itr Ho DQAtt Erlh

Nr

ATINH

IAC[2] /

/ (T / 3600 * <TCH

TrafCarrD

R>)

Intra Cell Quality HandoverAttempts per Erlanghour

Uplink

itr Ho UQAtt Erlh

Nr

ATINH

IAC[1] /

/ (T / 3600 * <TCH

TrafCarrD

R>)

TCH TrafficCarried

tch Traf Carr

Erl

<TCH

TrafCarrD

R>

Object

<Cell Sym

bolic>:<TRX Id>

Time

HH

:mm

Base Station Link Quality Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 163: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 163

5.1.16 Correlated Data Histogram Reports

Report Name: (a) Correlated Rx Level to Rx Quality on Uplink(b) Correlated Rx Level to Rx Quality on Downlink(c) Correlated Rx Level to Timing Advance on Uplink(d) Correlated Rx Level to Timing Advance on Downlink(e) Correlated FER to Rx Qualilty on Uplink

Report Short Name: (a) CorrRxLevRxQualUL(b) CorrRxLevRxQualDL(c) CorrRxLevTAUL(d) CorrRxLevTADL(e) CorrFERRxQualUL

Target Groups: Network Optimisation.

Description: Certain BR6.0 measurements (namely CRXLVQUU, CRXLVQUD,CRXLVTAU, CRXLVTAD and CFERRXQU) require a specific type of reportlayout to enable a graphical, user-friendly, use-case oriented, presentation ofthe provided histograms.All these reports have exactly the same structure which corresponds to an8x8 matrix with the following results:(a) CorrRxLevRxQualUL report provides all 64 counters from CRXLVQUU(b) CorrRxLevRxQualDL report provides all 64 counters from CRXLVQUD(c) CorrRxLevTAUL report provides all 64 counters from CRXLVTAU(d) CorrRxLevTADL report provides all 64 counters from CRXLVTAD(e) CorrFERRxQualUL report provides all 64 counters from CFERRXQUThe final goal for these reports is to present the previous information as 3Dgraphics where, in the current implementation, the "zz" axis corresponds to agrey scale for the total number of times a certain (x, y) combination pairoccurred during the evaluation period.

There are three possible combinations of labels for the "xx" and "yy" axis:• Case one of "Rx Level to Rx Quality" reports is being visualised, rows

correspond to 8 RxLev ranges ("xx" axis) and columns correspond to 8RxQual ranges ("yy xx" axis).

• Case one of "Rx Level to Timing Advance" reports is being visualised,rows correspond to 8 RxLev ranges ("xx" axis) and columns correspond to8 TA ranges ("yy" axis).

• Case "FER to Rx Quality" report is the one being visualised, rowscorrespond to 8 FER ranges ("xx" axis) and columns correspond to 8RxQual ranges ("yy" axis).

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "Total"

"Total DTL""Total SPBH"

(e) BSC BSC Symbolic Name(f) BTS Cell Symbolic Name

Input Parameters:

(g) TRX TRX Id

Page 164: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

164 E200301-01-214-V10.0I-01

Measurements: From SCANTRX functional group:CFERRXQUCRXLVQUDCRXLVQUUCRXLVTAUCRXLVTAD

Remarks: SCANTRX measurements can't be collected simultaneously.

Layout:

Example for the "Correlated Rx Level to Rx Quality on Uplink" report selecting AGGREGATION crite-ria equal to "Total DTL":

Page 165: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 165

5.2 UTRAN

Page 166: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

166 E200301-01-214-V10.0I-01

5.2.1 UTRAN Overview Report

Report Name: UTRAN Overview Report

Report Short Name: Utran_Overview

Target Groups: Network Operation, Network Optimisation, Network Management.

Description: This report provides information like Call Setup Success Rates, Number ofCall Attempts and Mean Call Duration per QoS class. Or like general qualityindicators for Hard and Soft Handovers and, moreover the connection droprate.The report results can be provided on a per cell or per RNC basis.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"DTOT""TEVL"

(e) RNC RNC Symbolic Name(f) UCELL Utran Cell ID

Input Parameters:

(g) RNC_TOTALS """RNC Totals"

The results will be pre-sented per RNC case"RNC Totals" report ischosen.

Measurements: From RNC:hhoAllOutAtthhoAllOutFailhhoAllOutSucciuRelCmdiuRelReqrabEstabAttrabEstabFailrabEstabSuccrabPerQosClassrabRelrrcEstabAttrrcEstabSuccshoAddIntraNodeBAttshoAddIntraNodeBSuccshoAddInterRncAttshoAddInterRncSuccshoAddIntraRncAttshoAddIntraRncSuccuesPerActiveLinkSetSizeprlcUsage (only if user chooses the RNC Totals report variant)

Remarks: None.

Page 167: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 167

Layout:

MHT

Back

g

sec T * rabsPerQosClass[BG][All] /

/ rabEstabSucc[BG][All]

CS S

RBa

ckg

% >95 100 * (rrcEstabSucc[3,8]/ rrcEstabAtt[3,8]) *

* (rabEstabSucc[BG][All] / rabEstabAtt[BG][All])

Back

grou

nd

CS A

ttBa

ckg

Nr rrcEstabAtt[3,8]

MHT

Inte

r

sec T * rabsPerQosClass[IN][All] /

/ rabEstabSucc[IN][All]CS

SR

Inte

r

% >50 100 * (rrcEstabSucc[2,7]/ rrcEstabAtt[2,7]) *

* (rabEstabSucc[IN][All] / rabEstabAtt[IN][All])

Inter

activ

e

CS A

ttIn

ter

Nr rrcEstabAtt[2,7]

MHT

Stre

am

sec T * rabsPerQosClass[ST][All] /

/ rabEstabSucc[ST][All]

CS S

RSt

ream % >50 100 * (rrcEstabSucc[1,6]/ rrcEstabAtt[1,6]) *

* (rabEstabSucc[ST][All] / rabEstabAtt[ST][All])

Stre

aming

CS A

ttSt

ream Nr rrcEstabAtt[1,6]

MHT

Conv

sec T * rabsPerQosClass[CV][All] /

/ rabEstabSucc[CV][All]

CS S

RCo

nv % >95 100 * (rrcEstabSucc[0,5]/ rrcEstabAtt[0,5]) *

* (rabEstabSucc[CV][All] / rabEstabAtt[CV][All])

RRC

Attem

pts, A

cces

s Pro

babil

ity an

d Mea

n Hold

ing T

ime p

er Q

oS

Conv

ersa

tiona

l

CS A

ttCo

nv Nr rrcEstabAtt[0,5]

CSSR

Acce

ssPr

obab

ility

CS S

R

% >80 <CSSRAccProb>

Call

Setup

s

CS Nr rabEstabASucc[All]

Objec

t

<Utran Cell Id>

Tim

e

HH:mm

UTRA

N Ov

ervie

w Re

port

<AGG

REGA

TION

>St

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 168: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

168E200301-01-214-V10.0I-01

Layout (cont):

Inter-RATHO QualityIndicator

I-RAT HO QI

%

<ISHO

QI>

Hard HOQuality

Indicator

HHO QI

%

<HH

OQ

I>

Soft HO RateRLN=1

SHO Rate 1

%

<SHO

Rate_1>

Branch AdditionQuality Indicator

branch Add QI

%

<BranchAddQI>

USSR Multi-RAB

USSR Multi RAB

%

<USSR

MultiR

AB>

USSR AccessProbability

USSR Acc Prob

%

<USSR

AccProb>

AbnormalConnection

Release Rate

un Normal Con RR

%

<UnN

ormalC

RR

>

con DR

%

<ConD

R>

Connection DropRate and Number

con D

Nr

<ConD

>

Object

<Utran C

ell Id>

Time

HH

:mm

UTRAN Overview Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 169: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 169

5.2.2 Connection Drop per Cause Report

Report Name: Connection Drop per Cause Report

Report Short Name: ConnectionDropPerCause

Target Groups: Network Operation, Network Optimisation.

Description: The purpose of this report is to provide the list of reasons for connectiondrops. The report should be presented as pie chart - one per cell or per RNC– to enable the analysis of the relative weight of each cause. Please note thatthe actual percentage value for each cause is displayed in SPOTS interface.Additionally, to simplify the chart analysis by removing unnecessary informa-tion, all causes with zero occurrences are filtered on the report.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"Total""TEVL"

(e) RNC RNC Symbolic Name

Input Parameters:

(f) UCELL Utran Cell ID

Measurements: From RNC:iuRelReq

Remarks: None.

Page 170: Spots 10.0 Performance Reports

170E200301-01-214-V10.0I-01

Layout:UTRAN Connection Drop per Cause Report <AGGREGATION>

Start Date: <START_DATE>End Date: <END_DATE>

S

iemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Page 171: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 171

5.2.3 RRC Analysis Report

Report Name: RRC Analysis Report

Report Short Name: RRCAnalysisReport

Target Groups: Network Operation, Network Optimisation.

Description: The purpose of this report is to provide RRC related information in a per cellbasis.The information concerns the number of RRC connection establishmentattempts, respective success rate and failure rates per cause. Besides it alsodetails the number and the reasons for RRC drop.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"DTOT""TEVL"

(e) RNC RNC Symbolic Name

Input Parameters:

(f) UCELL Utran Cell ID

Measurements: From RNC:rrcEstabAttrrcEstabFailrrcEstabSuccrrcRelCcchrrcRelDcch

Remarks: None.

Page 172: Spots 10.0 Performance Reports

172E200301-01-214-V10.0I-01

Layout:

RRC EstablishmentFailures

est Fails

Nr

rrcEstabFail[all]

RRC EstablishmentSuccess Rate MO

est SR MO

%

<RrcEstabSR

Mo>

RRC EstablishmentAttempts MO

est Att MO

Nr

rrcEstabAtt[0..4,9]

RRC EstablishmentSuccess Rate MT

est SR MT

%

<RrcEstabSR

Mt>

RRCEstablishmentAttempts MT

est Att MT

Nr

rrcEstabAtt[5..8]

RRCEstablishmentSuccess Rate

est SR

%

>90

<RrcEstabSR>

RRCEstablishment

Attempts

est Att

Nr

rrcEstabAtt[all]

Object

<Utran C

ell Id>

Time

HH

:mm

RRC Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

S

iemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Page 173: Spots 10.0 Performance Reports

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

E200301-01-214-V10.0I-01173

Layout (cont):

Other

DR Other

%

<RR

CD

R_O

ther>

Re-establishmentReject

DR Re-est Rej

%

<RR

CD

R_3_0_4>

Congestion

DR Cong

%

<RR

CD

R_3_0_3>

Pre-emptiveRelease

DR Pre-emp Rel

%<R

RC

DR

_3_0_2>

RRC Drop Rate per Drop Cause

Unspecified

DR Unspec

%

<RR

CD

R_3_0_1>

RRCDrops

Drops

Nr

rrcRelD

ccH[1..4, O

ther] ++ rrcR

elCcch[1..4, O

ther]

Other

est FR Other

%

<RrcEstabFR

_Other>

No Reply fromthe UE

est FR No Reply

%

<RrcEstabFR

_NoR

eply>

Unspecified

est FR Unspec

%

<RrcEstabFR

_3_0_1>

RRC Establishment Failure per Failure Cause

Congestion

est FR Cong

%

<RrcEstabFR

_3_0_0>

Object

<Utran C

ell Id>

Time

HH

:mm

RRC Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 174: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

174 E200301-01-214-V10.0I-01

5.2.4 RRC Establishment per Cause Report

Report Name: RRC Establishment per Cause Report

Report Short Name: RRCEstablishmentPerCause

Target Groups: Network Operation, Network Optimisation.

Description: The purpose of this report is to provide the list of reasons for the Call Esta-blishment Procedure. The report should be presented as pie chart (one percell or per RNC) to enable the analysis of the relative weight of each cause.Please note that the actual percentage value for each cause is displayed inSPOTS interface. Additionally, to simplify the chart analysis by removingunnecessary information, all causes with zero occurrences are filtered on thereport.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"Total""TEVL"

(e) RNC RNC Symbolic Name

Input Parameters:

(f) UCELL Utran Cell Id

Measurements: From RNC:rrcEstabAtt

Remarks: None.

Page 175: Spots 10.0 Performance Reports

E200301-01-214-V10.0I-01175

Layout:RRC Establishment per Cause Report <AGGREGATION>

Start Date: <START_DATE>End Date: <END_DATE>

S

iemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

Page 176: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

176 E200301-01-214-V10.0I-01

5.2.5 RAB Analysis Report

Report Name: RAB Analysis Report

Report Short Name: RABAnalysisReport

Target Groups: Network Operation, Network Optimisation.

Description: The purpose of this report is to provide for each cell the number of RAB esta-blishment attempts, success rate, failure rate, drop rate, RAB release causes,etc. Separation is done between QoS classes, Packet Switched and CircuitSwitched traffic to obtain different RAB establishment success rates.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"DTOT""TEVL"

(e) RNC RNC Symbolic Name

Input Parameters:

(f) UCELL Utran Cell Id

Measurements: From RNC:iuRelCmdiuRelReqrabEstabAttrabEstabFailrabEstabSuccrabRel

Remarks: None.

Page 177: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 177

Layout:

est S

RBa

ckg

% 100 * rabEstabSucc[BG][all] / rabEstabAtt[BG][all]

Back

grou

nd

est A

ttBa

ckg

Nr rabEstabAtt[BG][all]

est S

RIn

ter

% 100 * rabEstabSucc[IN][all] / rabEstabAtt[IN][all]Int

erac

tive

est A

ttIn

ter

Nr rabEstabAtt[IN][all]es

t SR

Stre

am % 100 * rabEstabSucc[ST][all] / rabEstabAtt[ST][all]

Stre

aming

est A

ttSt

ream Nr rabEstabAtt[ST][all]

est S

RCo

nv % 100 * rabEstabSucc[CV][all] / rabEstabAtt[CV][all]

Conv

ersa

tiona

l

est A

ttCo

nv Nr rabEstabAtt[CV][all]

est

SR P

S

% <RabEstabSRPs>

PS

est

Att P

S

Nr rabEstabAtt[PS][all]

est

SR C

S

% <RabEstabSRCs>

CS

est

Att C

S

Nr rabEstabAtt[CS][all]

est S

R

% >90 <RabEstabSR>

RAB

Estab

lishm

ent A

ttemp

ts an

d Suc

cess

Rate

s

Total

est A

tt

Nr rabEstabAtt[all]

Objec

t

<Utran Cell Id>

Tim

e

HH:mm

RAB

Analy

sis R

epor

t <AG

GREG

ATIO

N>St

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 178: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

178E200301-01-214-V10.0I-01

Layout (cont):

ConnectionDrop Rate

conn DR

%

<ConD

R>

Other

abnRR Other

Nr

100 * rabRel[all][O

ther] / rabEstabSucc[all]

UnspecifiedFailure

abn RRUnspec Fail

Nr

100 * rabRel[all][115] / rabEstabSucc[all]

O&MIntervention

abn RRO&M Interv

Nr100 * rabR

el[all][113] / rabEstabSucc[all]

RepeatedIntegrity

Checking Fail

abn RRInteg Ck Fail

Nr

100 * rabRel[all][37] / rabEstabSucc[all]

Iu UPFailure

abn RRIu UP Fail

Nr

100 * rabRel[all][28] / rabEstabSucc[all]

Abnormal RAB Release Rate Per Cause

UTRANReason

abn RRUtran Reas

Nr

100 * rabRel[all][15] / rabEstabSucc[all]

RABReleaseRequests

RAB Rel Req

Nr

rabRel[all]

Failure Rate

est FR

%

<RabEstabFR

>

RAB Establishment Failure

Failures

est Fail

Nr

rabEstabFail[all]

Object

<Utran C

ell Id>

Time

HH

:mm

RAB Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 179: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 179

5.2.6 RAB Failure per Cause Report

Report Name: RAB Failure per Cause Report

Report Short Name: RABFailurePerCause

Target Groups: Network Operation, Network Optimisation.

Description: The purpose of this report is to provide the list of reasons for RAB failure.The report should be presented as pie chart (one per cell or per RNC) toenable the analysis of the relative weight of each cause.Please note that the actual percentage value for each cause is displayed inSPOTS interface. Additionally, to simplify the chart analysis by removingunnecessary information, all causes with zero occurrences are filtered on thereport.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"Total""TEVL"

(e) RNC RNC Symbolic Name

Input Parameters:

(f) UCELL Utran Cell Id

Measurements: From RNC:rabEstabFail

Remarks: None.

Page 180: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

180 E200301-01-214-V10.0I-01

Layout:RA

B Fa

ilure

per

Cau

se R

epor

t <AG

GREG

ATIO

N>St

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Page 181: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 181

5.2.7 Soft HO Analysis Report

Report Name: Soft HO Analysis Report

Report Short Name: SoftHOAnalysis

Target Groups: Network Operation, Network Optimisation.

Description: The purpose of this report is to provide the number and success rates eitherfor intra NodeB intra RNC and inter RNC branch additions. It also providesthe distribution between handover causes and the percentage of connectionsthat use 1, 2 or 3 radio links.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"DTOT""TEVL"

(e) RNC RNC Symbolic Name

Input Parameters:

(f) UCELL Utran Cell Id

Measurements: From RNC:rabEstabSuccshoAddInterRncAttshoAddInterRncSuccshoAddIntraNodeBAttshoAddIntraNodeBSuccshoAddIntraRncAttshoAddIntraRncSuccuesPerActiveLinkSetSize

Remarks: None.

Page 182: Spots 10.0 Performance Reports

182E200301-01-214-V10.0I-01

Layout:

Branch AdditionSuccess Rate

Inter RNC SR

%

<BranchAddSRInterR

NC

>

Inter RNC Soft Handovers

Branch AdditionAttempts

Inter Rnc Att

Nr

shoAddIntraRncAtt[all]

Branch AdditionSuccess Rate

Intra Rnc SR

%<BranchAddSR

IntraRN

C>

Intra RNC Soft Handovers

Branch AdditionSuccess Rate

Intra Rnc Att

Nr

shoAddIntraRncAtt[all]

Branch AdditionSuccess Rate

Intra NB SR

%

<BranchAddSRIntraN

odeB>

Intra NodeB Soft Handovers

Branch AdditionAttempts

Intra NB Att

Nr

shoAddIntraNodeBAtt[all]

Branch AdditionSuccess Rate

Branch Add SR

%

<BranchAddSR>

Object

<Utran C

ell Id>

Time

HH

:mm

Soft HO Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

S

iemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

Page 183: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 183

Layout (cont):

RLN

=3

SHO

Rate

3

% <SHORate_3>

RLN

=2

SHO

Rate

2

% <SHORate_2>

Soft H

O Ra

te pe

r RLN

RLN

=1

SHO

Rate

1

% <SHORate_1>

Othe

r Per

c

%

100 * (shoAddIntraNodeBAtt[Other] + shoAddIntraRncAtt[Other] ++ shoAddIntraRncAtt[Other]) / (shoAddIntraNodeBAtt[all] +

+ shoAddIntraRncAtt[all] + shoAddIntraRncAtt[all])

Othe

r Cau

ses

Othe

r

Nr shoAddIntraNodeBAtt[Other] + shoAddIntraRncAtt[Other] ++ shoAddIntraRncAtt[Other]

CPIC

H - 1

CPe

rc %

100 * (shoAddIntraNodeBAtt[4] + shoAddIntraRncAtt[4] ++ shoAddIntraRncAtt[4]) / (shoAddIntraNodeBAtt[all] +

+ shoAddIntraRncAtt[all] + shoAddIntraRncAtt[all])

CPIC

H Co

mpar

ison

(1C)

CPIC

H - 1

C

Nr shoAddIntraNodeBAtt[4] + shoAddIntraRncAtt[4] ++ shoAddIntraRncAtt[4]

CPIC

H - 1

A'Pe

rc %

100 * (shoAddIntraNodeBAtt[2] + shoAddIntraRncAtt[2] ++ shoAddIntraRncAtt[2]) / (shoAddIntraNodeBAtt[all] +

+ shoAddIntraRncAtt[all] + shoAddIntraRncAtt[all])

CPIC

H Co

mpar

ison

(1A'

)

CPIC

H - 1

A'

Nr shoAddIntraNodeBAtt[2] + shoAddIntraRncAtt[2] ++ shoAddIntraRncAtt[2]

CPIC

H - 1

APe

rc %

100 * (shoAddIntraNodeBAtt[1] + shoAddIntraRncAtt[1] ++ shoAddIntraRncAtt[1]) / (shoAddIntraNodeBAtt[all] +

+ shoAddIntraRncAtt[all] + shoAddIntraRncAtt[all])

SHO

Per C

ause

- Nu

mber

and D

istrib

ution

CPIC

H Co

mpar

ison

(1A)

CPIC

H - 1

A

Nr shoAddIntraNodeBAtt[1] + shoAddIntraRncAtt[1] ++ shoAddIntraRncAtt[1]

Objec

t

<Utran Cell Id>

Tim

e

HH:mm

Soft

HO A

nalys

is Re

port

<AGG

REGA

TION

>St

art D

ate: <

STAR

T_DA

TE>

End D

ate: <

END_

DATE

>

Date YYYY-MM-DD

Page 184: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

184 E200301-01-214-V10.0I-01

5.2.8 Branch Addition Failure per Cause Report

Report Name: Branch Addition Failure per Cause Report

Report Short Name: BranchAdditionFailPerCause

Target Groups: Network Operation, Network Optimisation.

Description: The purpose of this report is to provide the list of reasons for the BranchAddition Procedure. The report should be presented as pie chart (one per cellor per RNC) to enable the analysis of the relative weight of each causePlease note that the actual percentage value for each cause is displayed inSPOTS interface. Additionally, to simplify the chart analysis by removingunnecessary information, all causes with zero occurrences are filtered on thereport.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Max Peak"

"Total""TEVL"

(e) RNC RNC Symbolic Name

Input Parameters:

(f) UCELL Utran Cell Id

Measurements: From RNC:shoAddInterRncFailshoAddIntraNodeBFailshoAddIntraRncFail

Remarks: None.

Page 185: Spots 10.0 Performance Reports

E200301-01-214-V10.0I-01185

Layout:Branch Addition Failure per Cause Report <AGGREGATION>

Start Date: <START_DATE>End Date: <END_DATE>

S

iemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

Page 186: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

186 E200301-01-214-V10.0I-01

5.2.9 Hard HO Analysis Report

Report Name: Hard HO Analysis Report

Report Short Name: HardHOAnalysis

Target Groups: Network Operation, Network Optimisation.

Description: The purpose of the report is to provide numbers and success rates foroutgoing Hard Handovers, additionally that same information is also providedon a per cause basis. Other key performance indicators like the number ofoutgoing hard handover per call and the number of inter radio accesstechnology (I-RAT) handovers per call, are also provided within this report.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” means the 7previous complete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) AGGREGATION "SPBH Daily Peaks"

"DTOT""TEVL"

(e) RNC RNC Symbolic Name

Input Parameters:

(f) UCELL Utran Cell Id

Measurements: From RNC:hhoAllOutAtthhoAllOutFailhhoAllOutSuccrabEstabSucc

Remarks: None.

Page 187: Spots 10.0 Performance Reports

E200301-01-214-V10.0I-01187

Layout:

HHO OtherPerc

%

100 * hhoAllOutAtt[1][O

ther] / hhoAllOutAtt[1][all]

Other Cause

HHO AttOther

Nr

hhoAllOutAtt[1][O

ther]

HHO RadioReason Perc

%100 * hhoAllO

utAtt[1][43] / hhoAllOutAtt[1][all]

Relocation Desirable for Radio Reasons

HHO AttRadio Reason

Nr

hhoAllOutAtt[1][43]

HHO LoadCtrl Perc

%

100 * hhoAllOutAtt[1][0] / hhoAllO

utAtt[1][all]

Outgoing HHO Per Cause - Number and Distribution

Load Control

HHO AttLoad Ctrl

Nr

hhoAllOutAtt[1][0]

Drop Rate

HHO DR

%

<HH

OD

RIntraN

B>

Failure Rate

HHO FR

%

<HH

OFR

IntraNB>

Success Rate

HHO SR

%

<HH

OSR

IntraNB>

Outgoing Hard Handovers

Attempts

HHO Att

Nr

hhoAllOutAtt[1][all]

Object

<Utran C

ell Id>

Time

HH

:mm

Hard HO Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

S

iemens Perform

ance Reports (SPO

TS V10 Drop 4)

Siemens SA

Page 188: Spots 10.0 Performance Reports

Siemens SA

Siemens Perform

ance Reports (SPO

TS V10 Drop 4)

188E200301-01-214-V10.0I-01

Layout (cont):

OutgoingHHO

per Call

HHOper Call

Nr

<HH

OperC

allRateN

odeB>

Outgoing CSInter-RATper Call

CS I-RATHO per Call

Nr

<ISHO

perCallR

ate>

CS I-RAT HOOther Perc

%100 * hhoAllO

utAtt[5][Other] / hhoAllO

utAtt[5][all]

Other Causes

CS I-RATHO Att Other

Nr

hhoAllOutAtt[5][O

ther]

CS I-RAT HORadioReasonPerc

%

100 * hhoAllOutAtt[5][43] / hhoAllO

utAtt[5][all]

Outgoing CS Inter-RAT HO Per Cause - Number and Distribution

Relocation Desirable For Radio Reasons

CS I-RAT HOAttRadioReason

Nr

hhoAllHoO

utAtt[43]

Drop Rate

CS I-RATHO DR

%

<ISHO

OutC

SDR

pCell>

Failure Rate

CS I-RATHO FR

%

<ISHO

OutC

SFRpC

ell>

Success Rate

CS I-RATHO SR

%

<ISHO

OutC

SSRpC

ell>

Outgoing CS Inter-RAT Handovers

Attempts

CS I-RATHO Att

Nr

hhoAllOutAtt[5][all]

Object

<Utran C

ell Id>

Time

HH

:mm

Hard HO Analysis Report <AGGREGATION>Start Date: <START_DATE>

End Date: <END_DATE>

Date

YYYY-MM

-DD

Page 189: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 189

6 Real-Time Reports

SPOTS enables the visualisation of the performance indicators that are being collected and evaluatedagainst thresholds in real-time, with two special report layouts:

• Bar-Chart report

• Monitoring Panel report

These layouts are Real-Time module specific features and are not available in a Long-Term SPOTSinstallation.

Page 190: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

190 E200301-01-214-V10.0I-01

6.1 Bar-Chart Reports Visualization

This type of reports aims to give a correlation between values of the "MonitoredCounter" and otherindicators that might help troubleshooting causes for abnormal values.

The abnormal values can be detected by an alarm or by operator inspection of a performance report.The user can than call the report associated to that "MonitoredCounter" and check the values of therelated indicators in a top down approach. The related indicators are usually lower level information.Associated to those lower-level indicators, other bar-chart reports might exist enabling the user toproceed with the drill down until reaching a set of performance indicators closer to the origin of theproblem.

From the Alarm Browser it will be possible to select a specific alarm row and start a Bar-Chart RTreport.

The monitored counter (the observed performance indicator) that is affected by the alarm is alwayspresented together with additional pre-defined performance indicators.

These reports can also be called from the SPOTS-LT Report Task Tree where the reference counteris passed to the report as an extra parameter. But in this case the user will be able to select theevaluation period and will only have access to the standard outputs like any other long-term report.

Figure 2 – Reports Editor Interface.

Further, in each report description, it will be detailed the list of performance indicators that aregathered in each bar-chart report. Bar-chart report selection is done while specifying the"MonitoredCounter" from a list of possible performance indicators.

For more detailed description about functionality please consult [21].

Page 191: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 191

6.2 Monitoring Panel Reports Visualization

The “Monitoring Panel” is a report dedicated to graphically monitor specific network objects (e.g. BTS,MSC, RNC, ATM Switch) that have critical conditions.

These reports have 3 rows:• “Nr. Affected Nodes”: the first row displays the number of objects that match the defined critical

condition;• “Aggr. Value (Affected)”: the second row displays the aggregated value (total or average) of the

observed variable for all objects that match the defined critical condition and for the observationperiod.

• “Aggr. Value (Total)”: the third row displays the aggregated value of the observed variable, butfor all Nodes on the network.

For each indicator presented in the Panel Report two columns are presented:

• The Current value column (“C”): the time interval when PM data was last collected from thenetwork;

• The Maximum value column (“M”): the time interval when the reference performance indicatorreaches its maximum/minimum value.

The Panel Reports are auto-refreshed.

Figure 3 – Reports Editor Interface.

The user can click on the mouse right-button to access the Report launching facility that calls a pre-defined report with the same performance indicators and assuming the parameters:• Requested objects: <all exchanges that match the defined critical condition>;• Time period: <total observation period which comprises the last 4 hours>.

The pre-defined reports associated with the Monitoring Panel are not accessible from the SPOTS LT -Reports Task tree.

For more detailed description about functionality please consult [21].

Page 192: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

192 E200301-01-214-V10.0I-01

6.3 CN Circuit Switched Real-Time Reports

Page 193: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 193

6.3.1 MSC Monitoring Panel Report

Report Name: MSC Monitoring Panel Report

Report Short Name: MSC_report

Target Groups: Network Operation, Network Optimisation

Description: The MSC Monitoring panel provides an overview about the overload in thenetwork.The pre-defined report launched from the monitoring panel selects its outputdata restricting the evaluation period to the maximum value of TOTALLOAD,and including only objects for which at least one performance indicatorviolated its threshold according to the respective critical condition.

Name Possible Values Remarks

(a) condition_tchAssignSuccRate

Any value ≥0 and≤100

tchAssignSuccRateThreshold.Critical condition: "<"Default = 95%

(b) condition_callSuccRate

Any value ≥0 and≤100

callSuccRate Threshold.Critical condition: "<"Default = 90%

(c) condition_TOTALLOAD

Any value ≥0 and≤100

TOTALLOAD Threshold.Critical condition: ">"Default = 700mErl

Input Parameters:

(d) condition_HOSUCC Any value ≥0 and≤100

HOSUCC Threshold.Critical condition: "<"Default = 80%

Measurements: CPMSC

Remarks: none

Page 194: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

194 E200301-01-214-V10.0I-01

Layout:

MSC Monitoring Panel ReportStart Date: <START_DATE>

End Date: <END_DATE>

tchAssignSuccRate callSuccRate TOTALLOAD HOSUCC

% % mErl %Date Time Object

>95 >90 <700 >80

YYYY

-MM

-DD

HH

:mm

<Utra

n C

ell I

d>

< tch

Assi

gnSu

ccR

ate>

< cal

lSuc

cRat

e>

For C

lass

ic N

odes

(SR

*):

SYS

LOAD

CP:

TOTA

LLO

AD

For I

nnov

atio

n N

odes

(CS*

):SY

SLO

ADM

P:TO

TALL

OAD

<HO

SUC

C>

Page 195: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 195

6.3.2 EXCH Bar Chart Report

Report Name: EXCH Bar Chart Report

Report Short Name: EXCHOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Input Parameters: Name Possible Values Remarks

(a) MonitoredCounter "HOTRFS""MOCSETUP""MOCANSW""MTCSETUP""MTCANSW""EMERSUCC""EMERANSW""CIPHCTRL""HLRINTER""MOSMSUCC""MTSMSUCC""HONOTALO""TMSIREAL""INTRAMSC""HOFAIL""INTMSCB""INTMSCA""SUBMSCA""SUBMSCC""HOSUCC""REQAUTH""INSSUBDA""LUPSUCC""REQSMROU""SMDELIV""SENDAL""REQMSRN""IDREQVLR""AUTHPROC""INTRAVLR""INTERVLR""UNIMEI""MOSMS""MTSMS""EMPRESPA""SSRELOP""MSMEMAV""callSetupTime""lupTime""MOCSetupSucc""MTCSetupSucc"

The layout ofthe report willcontain differentindicatorsaccording to theMonitoredcounterselected.

Page 196: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

196 E200301-01-214-V10.0I-01

"mhtOrig""mhtTer""hoAtt""lupReq""emerCallAtt""ciphReq""unknEquip""imeiCkMsg""traffCarrOrig""traffCarrTer""mscTraffCarr""interrUnsSubsBeh""interrUnsSyst""interrToHlr""idReqCorrFail""idReqInterwPvlrFail""idReqAuthFail""smsOutgAtt""smsIncAtt""smsSerReqAtt""hoNotAllow""hoConference""intraMscAtt""intraMscRate""incInterMscAtt""incInterMscRate""outgInterMscAtt""outgInterMscRate""subsInterMscAAtt""subsInterMscCAtt""authDataReq""unsAuth""hlrSubs""unsInsSubDtMsgSubAdmin""unsInsSubDtMsg""unsRespInsSubDt""routingInfoReqSms""sentAlertSmsServCenter""provideMsrnReq""authReq""authWithIlegSubs""reqLupIntraVlr""reqLupInterVlr""unsRespSubsBeh""unsRespSyst""unsRespUnstrucDt""sucMsMemAvail""msMemAvailToHlr""traffCarrOutgPlmn""traffCarrOutgNotPlmn""subscribers""ownSubs""foreignSubs""CALLPLOAD""TOTALLOAD""TOTCPU""mscCallAtt""callSuccRate""tchAssignSuccRate"

(b) PERIOD_KEYWORD "Today" “Lastweek”

Page 197: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 197

"Yesterday""Lastweek"

means the 7previouscomplete dayscounting fromtoday.

(c) START_DATE Any date

(d) END_DATE Any date

(e) EXCH NE Symbolic Name

Measurements: MSCVLRCPHLR

Remarks: none

Layout Content:

If MonitoredCounter in:• HOTRFS• hoAtt• HOSUCC

Report presents:HOTRFS HOFAIL HOSUCC hoAtt

% % % Nr

If MonitoredCounter in:• callSetupTime• traffCarrOrig• MOCSetupSucc• MOCSETUP

Report presents:MOCSETUP MOCSetupSucc callSetupTime traffCarrOrig

% Nr sec Erl

If MonitoredCounter in:• EMERSUCC• emerCallAtt• EMERANSW

Report presents:EMERSUCC emerCallAtt EMERANSW

% Nr %

Page 198: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

198 E200301-01-214-V10.0I-01

If MonitoredCounter in:• ciphReq• CIPHCTRL

Report presents:CIPHCTRL ciphReq LUPSUCC lupReq

% Nr % Nr

If MonitoredCounter in:• HLRINTER• interrUnsSyst• interrToHlr• interrUnsSubsBeh

Report presents:HLRINTER interrUnsSubsBeh interrUnsSyst interrToHlr

% Nr Nr Nr

If MonitoredCounter in:• MOSMSUCC• smsOutgAtt

Report presents:MOSMSUCC smsOutgAtt smsIncAtt SMDELIV

% Nr Nr %

If MonitoredCounter in:• MTSMSUCC• smsIncAtt• SMDELIV

Report presents:MTSMSUCC smsIncAtt smsOutgAtt SMDELIV

% Nr Nr %

If MonitoredCounter in:• HONOTALO• hoConference• hoNotAllow• HOFAIL

Report presents:HONOTALO hoNotAllow HOFAIL hoConference

% Nr % Nr

If MonitoredCounter in:• TMSIREAL

Report presents:TMSIREAL tmsiReallocAtt LUPSUCC lupReq

% Nr % Nr

Page 199: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 199

If MonitoredCounter in:• intraMscAtt• intraMscRate• INTRAMSC

Report presents:INTRAMSC intraMscAtt intraMscRate hoAtt

% Nr % Nr

If MonitoredCounter in:• incInterMscAtt• incInterMscRate• INTMSCB

Report presents:INTMSCB incInterMscAtt incInterMscRate hoAtt

% Nr % Nr

If MonitoredCounter in:• outgInterMscAtt• outgInterMscRate• INTMSCA

Report presents:INTMSCA outgInterMscAtt outgInterMscRate hoAtt

% Nr % Nr

If MonitoredCounter in:• subsInterMscCAtt• subsInterMscAAtt• SUBMSCA• SUBMSCC

Report presents:SUBMSCA subsInterMscAAtt SUBMSCC subsInterMscCAtt

% Nr % Nr

If MonitoredCounter in:• authDataReq• unsAuth• hlrSubs• REQAUTH

Report presents:REQAUTH authDataReq unsAuth hlrSubs

% Nr Nr Nr

Page 200: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

200 E200301-01-214-V10.0I-01

If MonitoredCounter in:• unsInsSubDtMsgSubAdmin• unsInsSubDtMsg• unsRespInsSubDt• INSSUBDA

Report presents:INSSUBDA unsInsSubDtMsgSubAdmin unsInsSubDtMsg unsRespInsSubDt

% Nr Nr Nr

If MonitoredCounter in:• lupReq• lupTime• LUPSUCC

Report presents:LUPSUCC lupReq lupTime

% Nr sec

If MonitoredCounter in:• REQSMROU• routingInfoReqSms

Report presents:REQSMROU routingInfoReqSms SENDAL REQMSRN

% Nr % %

If MonitoredCounter in:• SENDAL• sentAlertSmsServCenter

Report presents:SENDAL sentAlertSmsServCenter REQSMROU REQMSRN

% Nr % %

If MonitoredCounter in:• REQMSRN• provideMsrnReq

Report presents:REQMSRN provideMsrnReq REQSMROU SENDAL

% Nr % %

If MonitoredCounter in:• idReqCorrFail• idReqInterwPvlrFail• idReqAuthFail• IDREQVLR

Report presents:IDREQVLR idReqCorrFail idReqInterwPvlrFail idReqAuthFail

% Nr Nr Nr

Page 201: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 201

If MonitoredCounter in:• authReq• authWithIlegSubs• AUTHPROC

Report presents:AUTHPROC authReq authWithIlegSubs

% Nr Nr

If MonitoredCounter in:• reqLupIntraVlr• reqLupInterVlr• INTERVLR• INTRAVLR

Report presents:INTRAVLR INTERVLR reqLupIntraVlr reqLupInterVlr

% % Nr Nr

If MonitoredCounter in:• imeiCkMsg• unknEquip• UNIMEI

Report presents:UNIMEI unknEquip imeiCkMsg

% Nr Nr

If MonitoredCounter in:• MOSMS• smsSerReqAtt

Report presents:MOSMS smsSerReqAtt MTSMS SMDELIV

% Nr % %

If MonitoredCounter in:• MTSMS

Report presents:MTSMS smsIncAtt MOSMS SMDELIV

% Nr % %

If MonitoredCounter in:• EMPRESPA

Report presents:EMPRESPA authDataReq hlrSubs

% Nr Nr

Page 202: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

202 E200301-01-214-V10.0I-01

If MonitoredCounter in:• SSRELOP• unsRespUnstrucDt• unsRespSyst• unsRespSubsBeh

Report presents:SSRELOP unsRespSubsBeh unsRespSyst unsRespUnstrucDt

% Nr Nr Nr

If MonitoredCounter in:• MSMEMAV• msMemAvailToHlr• sucMsMemAvail

Report presents:MSMEMAV sucMsMemAvail msMemAvailToHlr

% Nr Nr

If MonitoredCounter in:• mscTraffCarr• traffCarrOutgNotPlmn• traffCarrOutgPlmn

Report presents:mscTraffCarr traffCarrOutgNotPlmn traffCarrOutgPlmn traffCarrTer

Erl Erl Erl Erl

If MonitoredCounter in:• subscribers• ownSubs• foreignSubs

Report presents:subscribers ownSubs foreignSubs

Nr Nr Nr

If MonitoredCounter in:• CALLPLOAD• TOTALLOAD• TOTCPU• mscCallAtt

Report presents:CALLPLOAD TOTALLOAD TOTCPU mscCallAtt

mErl mErl Nr Nr

Page 203: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 203

If MonitoredCounter in:• callSuccRate• tchAssignSuccRate

Report presents:callSuccRate mscCallAtt tchAssignSuccRate TOTALLOAD

% Nr % mErl

If MonitoredCounter in:• mhtOrig• MOCANSW

Report presents:MOCANSW MOCSetupSucc mhtOrig traffCarrOrig

% Nr sec ErlIf MonitoredCounter in:• MTCSETUP• traffCarrTer• MTCSetupSucc

Report presents:MTCSETUP MTCSetupSucc callSetupTime traffCarrTer

% Nr sec Erl

If MonitoredCounter in:• mhtTer• MTCANSW

Report presents:MTCANSW MTCSetupSucc mhtTer traffCarrTer

Nr Nr sec Erl

Page 204: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

204 E200301-01-214-V10.0I-01

6.3.3 LOCAR Bar Chart Report

Report Name: LOCAR Bar Chart Report

Report Short Name: LOCAROC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) LOCAR Local Area Code

Input Parameters:

(e) MonitoredCounter "PAGEREQ""succPag""pagProc""retryPag"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: LOCAREA

Remarks: none

Layout Content:

If MonitoredCounter in:• succPag• pagProc• retryPag• PAGEREQ

Report presents:PAGEREQ succPag pagProc retryPag

% Nr Nr Nr

Page 205: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 205

6.3.4 CELL Bar Chart Repor t

Report Name: CELL Bar Chart Report

Report Short Name: CELLOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) CELL Cell Id

Input Parameters:

(e) MonitoredCounter "ACDCSUCC""CSDCSUCC""callAtt""callsWithAswr"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: INTCREL

Remarks: none

Layout Content:

If MonitoredCounter in:• callAtt• callsWithAswr• ACDCSUCC• CSDCSUCC

Report presents:ACDCSUCC CSDCSUCC CallsWithAswr CallAtt

% % Nr Nr

Page 206: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

206 E200301-01-214-V10.0I-01

6.3.5 ANGRP Bar Chart Report

Report Name: ANGRP Bar Chart Report

Report Short Name: ANGRPOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) ANGRP Announcement Group

Input Parameters:

(e) MonitoredCounter "totalCalls""succCalls""TC_N""TC"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: ANGRP

Remarks: none

Layout Content:

If MonitoredCounter in:• totalCalls• succCalls• TC_N• TC

Report presents:totalCalls succCalls TC_N TC

Nr Nr dErl dErl

Page 207: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 207

6.4 CN Packet Switched Real-Time Reports

Page 208: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

208 E200301-01-214-V10.0I-01

6.4.1 BIAS Load Monitoring Panel Report

Report Name: BIAS Load Monitoring Panel Report

Report Short Name: BIASLoad_report

Target Groups: Network Operation, Network Optimisation

Description: The BIAS Load Monitoring panel provides an overview about the load on theBIAS processors.The pre-defined report launched from the monitoring panel selects its outputdata restricting the evaluation period to the maximum value ofbiasLoadMonProcessorUsage, and including only objects for which at leastone performance indicator violated its threshold according to the respectivecritical condition.

Name Possible Values Remarks

(a) condition_TotalIngressOvlDiscards

Any value ≥0 and≤100

TotalIngressOvlDiscardsThreshold.Critical condition: ">"Default = 0

(b) condition_TotalEgressOvlDiscards

Any value ≥0 and≤100

TotalEgressOvlDiscardsThreshold.Critical condition: ">"Default = 0

(c) condition_HeavyOvlEvtCount

Any value ≥0 and≤100

HeavyOvlEvtCountThreshold.Critical condition: ">"Default = 0

(d) condition_ProcessorUsage

Any value ≥0 and≤100

ProcessorUsageThreshold.Critical condition: ">"Default = 70%

Input Parameters:

(e) condition_InputBufferUsage

Any value ≥0 and≤100

InputBufferUsageThreshold.Critical condition: ">"Default = 10%

Measurements: biasLoad

Remarks: none

Page 209: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 209

Layout:

Bias Load Monitoring Panel ReportStart Date: <START_DATE>

End Date: <END_DATE>

TotalIngressOvlDiscards

TotalEgressOvlDiscards

HeavyOvlEvtCount ProcessorUsage InputBufferUsage

Nr Nr Nr % %Date Time Object

=0 =0 =0 <70 <10

YYYY

-MM

-DD

HH

:mm

<Utra

n C

ell I

d>

<bia

sLoa

dMon

Tota

lIngr

essO

vlD

isca

rds>

<bia

sLoa

dMon

Tota

lEgr

essO

vlD

isca

rds>

< bia

sLoa

dMon

Hea

vyO

vlEv

tCou

nt>

<bia

sLoa

dMon

Proc

esso

rUsa

ge>

< bia

sLoa

dMon

Inpu

tBuf

ferU

sage

>

Page 210: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

210 E200301-01-214-V10.0I-01

6.4.2 APN Bar Chart Report

Report Name: APN Bar Chart Report

Report Short Name: APNOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) MonitoredCounter " tspscApnAttActivateSessions""tspscApnSuccActivateSessions""tspscApnCurrentSessions""tspscApnActivationSuccRate"

The layout of thereport will containdifferentindicatorsaccording to theMonitored counterselected.

(b) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek”means the 7previous completedays countingfrom today.

(c) START_DATE Any date(d) END_DATE Any date

Input Parameters:

(e) APN Application Point Number

Measurements: GPRS-apn

Remarks: none

Layout Content:

If MonitoredCounter in:• tspscApnActivationSuccRate• tspscApnAttActivateSessions• tspscApnSuccActivateSessions• tspscApnCurrentSessions

Report presents:

tspscApnActivatioSuccRate tspscApnSuccActivateSessions

tspscApnCurrentSessions

tspscApnAttActivateSessions

% Nr Nr Nr

Page 211: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 211

6.4.3 CARD Bar Chart Report

Report Name: CARD Bar Chart Report

Report Short Name: CARDOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek”means the 7previouscomplete dayscounting fromtoday.

(b) START_DATE Any date(c) END_DATE Any date(d) CARD Processor Card

Input Parameters:

(e) MonitoredCounter "gtpInPkts""gtpInOctets""gtpInRejectedPkts""gtpOutDataOctets""gtpOutSigOctets""gtpInRejectionRate""tspcSuccessfulSessions""tspcRefusedSessions""tspcCurrentSessions""tspcSessionSuccRate""qosInteracDataPktsCounter""qosBackgrDataPktsCounter""qosDataPkts""ovNbrDiscDataHighPrio""ovNbrDiscDataLowPrio""ovNbrDiscSignHighPrio""ovNbrDiscSignLowPrio"

The layout ofthe report willcontain differentindicatorsaccording to theMonitoredcounterselected.

Measurements: GPRS-gtpGPRS-qosGPRS-ovlGPRS-tspc

Remarks: none

Page 212: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

212 E200301-01-214-V10.0I-01

Layout Content:

If MonitoredCounter in:• gtpOutDataOctets• gtpOutSigOctets

Report presents:gtpOutDataOctets gtpOutSigOctets gtpInRejectionRate gtpInOctets

bps bps % bps

If MonitoredCounter in:• gtpInRejectionRate• gtpInPkts• gtpInOctets• gtpInRejectedPkts

Report presents:gtpInRejectionRate gtpInOctets gtpInPkts gtpInRejectedPkts

% bps Pkts/s Pkts

If MonitoredCounter in:• tspcSessionSuccRate• tspcCurrentSessions• tspcRefusedSessions• tspcSuccessfulSessions

Report presents:tspcSessionSuccRate tspcSuccessfulSessions tspcRefusedSessions tspcCurrentSessions

% Nr Nr Nr

If MonitoredCounter in:• qosDataPkts• qosInteracDataPktsCounter• qosBackgrDataPktsCounter

Report presents:qosDataPkts qosBackgrDataPktsCounter qosInteracDataPktsCounter

Pkts/s Pkts/s Pkts/s

If MonitoredCounter in:• ovNbrDiscDataHighPrio• ovNbrDiscDataLowPrio• ovNbrDiscSignHighPrio• ovNbrDiscSignLowPrio

Report presents:ovNbrDiscDataHighPrio ovNbrDiscDataLowPrio ovNbrDiscSignHighPrio ovNbrDiscSignLowPrio

Nr Nr Nr Nr

Page 213: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 213

If MonitoredCounter in:• biasLoadMonTotalEgressOvlDiscards

Report presents:biasLoadMon

TotalEgressOvlDiscardsbiasLoadMon

HeavyOvlEvtCountbiasLoadMon

ProcessorUsagebiasLoadMon

InputBufferUsageNr Nr % %

If MonitoredCounter in:• biasLoadMonTotalIngressOvlDiscards• biasLoadMonHeavyOvlEvtCount• biasLoadMonProcessorUsage• biasLoadMonInputBufferUsage

Report presents:biasLoadMon

TotalIngressOvlDiscardsbiasLoadMon

HeavyOvlEvtCountbiasLoadMon

ProcessorUsagebiasLoadMon

InputBufferUsageNr Nr % %

Page 214: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

214 E200301-01-214-V10.0I-01

6.4.4 VRINDEX Bar Chart Report

Report Name: VRINDEX Bar Chart Report

Report Short Name: VRINDEXOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) VRINDEX Virtual Router Index

Input Parameters:

(e) MonitoredCounter "giNbrActiveSess""giNbrSuccSess""giNbrRefusedSess""giNbrOfRefusedSessLackIpAddress""giNbrSessUpperThresholdExceed""giSessActivationSuccRate"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: GPRS-gi

Remarks: none

Page 215: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 215

Layout Content:

If MonitoredCounter in:• giNbrActiveSess• giNbrSuccSess

Report presents:giNbrActiveSess giSessActivationSuccRate giNbrRefusedSess giNbrSuccSess

Nr % Nr Nr

If MonitoredCounter in:• giSessActivationSuccRate• giNbrRefusedSess• giNbrOfRefusedSessLackIpAddress• giNbrSessUpperThresholdExceed

Report presents:

giSessActivationSuccRate giNbrRefusedSess giNbrOfRefusedSessLackIpAddress

giNbrSessUpperThresholdExceed

% Nr Nr Nr

Page 216: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

216 E200301-01-214-V10.0I-01

6.4.5 SLOTPORT Bar Chart Report

Report Name: SLOTPORT Bar Chart Report

Report Short Name: SLOTPORTOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek”means the 7previouscomplete dayscounting fromtoday.

(b) START_DATE Any date(c) END_DATE Any date(d) SLOTPORT Slot Number concatenated

with Port Number

Input Parameters:

(e) MonitoredCounter "rnetAtmTxCells""rnetAtmDiscardsTxQueueOvfCells""rnetAtmCellHeaderErrorRatio""rnetAtmMisroutedCellRate""rnetAtmRxCells""rnetProtocolDSX3IntervalESs""rnetProtocolDSX3IntervalSESs""rnetProtocolDSX3IntervalERSs""rnetProtocolDSX3IntervalSERSs""sonetFarEndLineIntervalESs""sonetFarEndLineIntervalSESs""sonetFarEndLineIntervalCVs""sonetFarEndLineIntervalUASs""sonetFarEndPathIntervalESs""sonetFarEndPathIntervalSESs""sonetFarEndPathIntervalCVs""sonetFarEndPathIntervalUASs""sonetLineIntervalESs""sonetLineIntervalSES""sonetLineIntervalCVs""sonetLineIntervalUASs""sonetPathIntervalESs""sonetPathIntervalSESs""sonetPathIntervalCVs""sonetPathIntervalUASs""sonetSectionIntervalESs""sonetSectionIntervalSESs""sonetSectionIntervalSEFSs""sonetSectionIntervalCVs""ifOutDiscards""ifOutErrors""ifOutQLen"

The layout ofthe report willcontain differentindicatorsaccording to theMonitoredcounterselected.

Measurements: mib2interface36140-ATMInterfaceStatistics36140-STM1-FarEndLine36140-STM1-FarEndPath

Page 217: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 217

36140-STM1-Line36140-STM1-Path36140-STM1-section

Remarks: none

Layout Content:

If MonitoredCounter in:• rnetAtmDiscardsTxQueueOvfCells• rnetAtmTxCells

Report presents:rnetAtmTxCells rnetAtmDiscardsTxQueueOvfCells rnetAtmRxCells

bps Nr bps

If MonitoredCounter in:• rnetAtmRxCells• rnetAtmMisroutedCellRate• rnetAtmCellHeaderErrorRatio

Report presents:

rnetAtmRxCells rnetAtmTxCells rnetAtmCellHeaderErrorRatio rnetAtmMisroutedCellRate

bps bps % %

If MonitoredCounter in:• rnetProtocolDSX3IntervalESs• rnetProtocolDSX3IntervalSESs• rnetProtocolDSX3IntervalERSs• rnetProtocolDSX3IntervalSERSs

Report presents:

rnetProtocolDSX3IntervalESs rnetProtocolDSX3IntervalSESs

rnetProtocolDSX3IntervalERSs

rnetProtocolDSX3IntervalSERSs

sec sec sec sec

If MonitoredCounter in:• sonetFarEndLineIntervalESs• sonetFarEndLineIntervalSESs• sonetFarEndLineIntervalCVs• sonetFarEndLineIntervalUASs

Report presents:

sonetFarEndLineIntervalESs sonetFarEndLineIntervalSESs sonetFarEndLineIntervalCVs

sonetFarEndLineIntervalUASs

sec sec sec sec

Page 218: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

218 E200301-01-214-V10.0I-01

If MonitoredCounter in:• sonetFarEndPathIntervalESs• sonetFarEndPathIntervalSESs• sonetFarEndPathIntervalCVs• sonetFarEndPathIntervalUASs

Report presents:

sonetFarEndPathIntervalESs sonetFarEndPathIntervalSESs sonetFarEndPathIntervalCVs

sonetFarEndPathIntervalUASs

sec sec sec sec

If MonitoredCounter in:• sonetLineIntervalESs• sonetLineIntervalSES• sonetLineIntervalCVs• sonetLineIntervalUASs

Report presents:

sonetLineIntervalESs sonetLineIntervalSES sonetLineIntervalCVs sonetLineIntervalUASs

sec sec sec sec

If MonitoredCounter in:• sonetPathIntervalESs• sonetPathIntervalSESs• sonetPathIntervalCVs• sonetPathIntervalUASs

Report presents:

sonetPathIntervalESs sonetPathIntervalSESs sonetPathIntervalCVs sonetPathIntervalUASs

sec sec sec sec

If MonitoredCounter in:• sonetSectionIntervalESs• sonetSectionIntervalSESs• sonetSectionIntervalSEFSs• sonetSectionIntervalCVs

Report presents:

sonetSectionIntervalESs sonetSectionIntervalSESs sonetSectionIntervalSEFSs

sonetSectionIntervalCVs

sec sec sec sec

If MonitoredCounter in:• ifOutDiscards• ifOutOctets• ifOutErrors• ifOutQLen

Report presents:

ifOutDiscards ifOutErrors ifOutQLen ifOutOctets

Nr Nr Nr bps

Page 219: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 219

6.4.6 DLC Bar Chart Report

Report Name: DLC Bar Chart Report

Report Short Name: DLCOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) DLC Data Link Connection

Input Parameters:

(e) MonitoredCounter "frPVCEndptInDiscards""frPVCEndptInOctets""frPVCEndptOutOctets""frPVCEndptInDiscardRate"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: 36140-frPVCEndpointStatistics

Remarks: none

Layout Content:

If MonitoredCounter in:• frPVCEndptInDiscards• frPVCEndptInOctets• frPVCEndptOutOctets• frPVCEndptInDiscardRate

Report presents:frPVCEndptInDiscardRate frPVCEndptOutOctets frPVCEndptInOctets frPVCEndptInDiscards

% bps bps Nr

Page 220: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

220 E200301-01-214-V10.0I-01

6.4.7 VPL Bar Chart Report

Report Name: VPL Bar Chart Report

Report Short Name: VPLOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) VPL Virtual Path Link

Input Parameters:

(e) MonitoredCounter "atmVplStatTotalCellIns""atmVplStatTotalDiscards""atmVplStatTotalCellOuts""atmVplStatDiscardRate"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: 36140-atmEndPoint-vpl

Remarks: none

Layout Content:

If MonitoredCounter in:• atmVplStatTotalCellIns• atmVplStatTotalDiscards• atmVplStatTotalCellOuts• atmVplStatDiscardRate

Report presents:atmVplStatTotalCellIns atmVplStatTotalDiscards atmVplStatTotalCellOuts atmVplStatDiscardRate

bps Nr bps %

Page 221: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 221

6.4.8 VCL Bar Chart Report

Report Name: VCL Bar Chart Report

Report Short Name: VCLOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) VCL Virtual Circuit Link

Input Parameters:

(e) MonitoredCounter "atmVclStatTotalCellIns""atmVclStatTotalDiscards""atmVclStatTotalCellOuts""atmVclStatDiscardRate"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: 36140-atmEndPoint-vcl

Remarks: none

Layout Content:

If MonitoredCounter in:• atmVclStatTotalCellIns• atmVclStatTotalDiscards• atmVclStatTotalCellOuts• atmVclStatDiscardRate

Report presents:atmVclStatTotalCellIns atmVclStatTotalDiscards atmVclStatTotalCellOuts atmVclStatDiscardRate

bps Nr bps %

Page 222: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

222 E200301-01-214-V10.0I-01

6.4.9 MIB2IFINDEX Bar Chart Report

Report Name: MIB2IFINDEX Bar Chart Report

Report Short Name: MIB2IFINDEXOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) MIB2IFINDEX MIB2 Interface Index

Input Parameters:

(e) MonitoredCounter "ifSpeed""ifOperStatus""ifInOctets""ifInDiscards""ifInErrors""ifInUnknownProtos""ifOutOctets"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: mib2interface

Remarks: none

Layout Content:

If MonitoredCounter in:• ifInOctets• ifOutOctets• ifOperStatus• ifSpeed

Report presents:ifInOctets ifOutOctets ifOperStatus ifSpeed

bps bps Nr bps

Page 223: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 223

If MonitoredCounter in:• ifInDiscards• ifInErrors• ifInUnknownProtos

Report presents:ifInDiscards ifInErrors ifInUnknownProtos ifInOctets

Nr Nr Nr bps

Page 224: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

224 E200301-01-214-V10.0I-01

6.4.10 VR Bar Chart Report

Report Name: VR Bar Chart Report

Report Short Name: VROC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) VR Virtual Router ID

Input Parameters:

(e) MonitoredCounter "ipInReceives""ipInHdrErrors""ipInAddrErrors""ipForwDatagrams""ipInUnknownProtos""ipInDiscards""ipInDelivers""ipOutRequests""ipOutDiscards""ipOutNoRoutes""ipReasmReqds""ipReasmOKs""ipReasmFails""ipFragOKs""ipFragFails""ipFragCreates""ipRoutingDiscards""ipFragFailRate""ipReasmFailRate"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: mib2ip

Remarks: none

Page 225: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 225

Layout Content:

If MonitoredCounter in:• ipInReceives• ipInDelivers• ipForwDatagrams

Report presents:ipInReceives ipInDelivers ipInDiscards ipForwDatagrams

Pkts/s Pkts/s Nr Nr

If MonitoredCounter in:• ipInDiscards• ipInHdrErrors• ipInUnknownProtos• ipInAddrErrors

Report presents:ipInDiscards ipInHdrErrors ipInAddrErrors ipInUnknownProtos

Nr Nr Nr Nr

If MonitoredCounter in:• ipOutRequests• ipOutDiscards• ipOutNoRoutes• ipRoutingDiscards

Report presents:ipOutRequests ipOutDiscards ipOutNoRoutes ipRoutingDiscards

Pkts/s Nr Nr Nr

If MonitoredCounter in:• ipReasmReqds• ipReasmOKs• ipReasmFails• ipReasmFailRate

Report presents:ipReasmReqds ipReasmOKs ipReasmFails ipReasmFailRate

Nr Nr Nr %

If MonitoredCounter in:• ipFragOKs• ipFragCreates• ipFragFailRate• ipFragFails

Report presents:ipFragOKs ipFragFails ipFragCreates ipFragFailRate

bps bps Nr %

Page 226: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

226 E200301-01-214-V10.0I-01

6.4.11 RADIUSACC Bar Char t Report

Report Name: RADIUSACC Bar Chart Report

Report Short Name: RADIUSACCOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek”means the 7previouscomplete dayscounting fromtoday.

(b) START_DATE Any date(c) END_DATE Any date(d) RADIUSACC RADIUS Accounting Server

Input Parameters:

(e) MonitoredCounter "radiusAccClientRoundTripTime""radiusAccClientRequests""radiusAccClientRetransmissions""radiusAccClientResponses""radiusAccClientMalformedResponses""radiusAccClientBadAuthenticators""radiusAccClientPendingRequests""radiusAccClientTimeouts""radiusAccClientUnknownTypes""radiusAccClientPacketsDropped""radiusAccProcSuccRate""radiusAccClientRespFailureRate""radiusAccClientRetransRate"“radiusAccSuccessfullyReceived”

The layout ofthe report willcontain differentindicatorsaccording to theMonitoredcounterselected.

Measurements: mib2radiusAcc

Remarks: none

Page 227: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 227

Layout Content:

If MonitoredCounter in:• radiusAccClientMalformedResponses• radiusAccClientBadAuthenticators• radiusAccClientUnknownTypes• radiusAccClientPacketsDropped• radiusAccClientResponses• radiusAccClientRespFailureRate

Report presents:radiusAccClient

ResponsesradiusAccClientRespFailureRate A B

Nr % Nr Nr

A = The last samples of the following indicators (radiusAccClientMalformedResponses;radiusAccClientBadAuthenticators; radiusAccClientUnknownTypes; radiusAccClientPacketsDropped)are compared and the Indicator with the highest value is shown in this column. Or, case the highestbelongs to the MonitoredCounter, the Indicator selected is the one with the second highest value.

B = MonitoredCounter if MonitoredCounter in (radiusAccClientMalformedResponses;radiusAccClientBadAuthenticators; radiusAccClientUnknownTypes; radiusAccClientPacketsDropped)or else, the second highest value from the list: (radiusAccClientMalformedResponses;radiusAccClientBadAuthenticators; radiusAccClientUnknownTypes; radiusAccClientPacketsDropped)

If MonitoredCounter in:• radiusAccClientTimeouts• radiusAccClientRequests• radiusAccClientRoundTripTime• radiusAccClientPendingRequests

Report presents:radiusAccClient

TimeoutsradiusAccClientRoundTripTime

radiusAccClientRequests

radiusAccClientPendingRequests

Nr sec Nr Nr

If MonitoredCounter in:• radiusAccProcSuccRate• radiusAccSuccessfullyReceived

Report presents:radiusAccProc

SuccRateradiusAcc

SuccessfullyReceivedradiusAccClient

RequestsradiusAccClientRespFailureRate

% Nr Nr %

If MonitoredCounter in:• radiusAccClientRetransRate• radiusAccClientRetransmissions

Report presents:radiusAccClient

RetransRateradiusAccClientRetransmissions

radiusAccSuccessfullyReceived

radiusAccClientRequests

% Nr Nr Nr

Page 228: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

228 E200301-01-214-V10.0I-01

6.4.12 RADIUSAUTH Bar Chart Report

Report Name: RADIUSAUTH Bar Chart Report

Report Short Name: RADIUSAUTHOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek”means the 7previouscomplete dayscounting fromtoday.

(b) START_DATE Any date(c) END_DATE Any date(d) RADIUSAUTH RADIUS Authentication Server

Input Parameters:

(e) MonitoredCounter "radiusAuthClientRoundTripTime""radiusAuthClientAccessRequests""radiusAuthClientAccessRetransmissions""radiusAuthClientAccessAccepts""radiusAuthClientAccessRejects""radiusAuthClientAccessChallenges""radiusAuthClientMalformedAccessResponses""radiusAuthClientBadAuthenticators""radiusAuthClientPendingRequests""radiusAuthClientTimeouts""radiusAuthClientUnknownTypes""radiusAuthClientPacketsDropped""radiusAuthProcSuccRate""radiusAuthClientRespFailureRate""radiusAuthClientRetransRate"“radiusAuthSuccessfullyReceived”“TotalIncomingPackets”

The layout ofthe report willcontaindifferentindicatorsaccording tothe Monitoredcounterselected

Measurements: mib2radiusAuth

Remarks: none

Page 229: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 229

Layout Content:

If MonitoredCounter in:• radiusAuthClientMalformedAccessResponses• radiusAuthClientRespFailureRate• radiusAuthClientUnknownTypes• radiusAuthClientBadAuthenticators• radiusAuthClientPacketsDropped

Report presents:

TotalIncomingPackets radiusAuthClientRespFailureRate A B

Nr % Nr Nr

A = The last samples of the following indicators (radiusAuthClientMalformedAccessResponses;radiusAuthClientBadAuthenticators; radiusAuthClientUnknownTypes;radiusAuthClientPacketsDropped) are compared and the Indicator with the highest value is shown inthis column. Or, case the highest belongs to the MonitoredCounter, the Indicator selected is the onewith the second highest value.

B = MonitoredCounter if MonitoredCounter in (radiusAuthClientMalformedAccessResponses;radiusAuthClientBadAuthenticators; radiusAuthClientUnknownTypes;radiusAuthClientPacketsDropped) or else, the second highest value from the list:(radiusAuthClientMalformedResponses; radiusAuthClientBadAuthenticators;radiusAuthClientUnknownTypes; radiusAuthClientPacketsDropped)

If MonitoredCounter in:• radiusAuthClientTimeouts• radiusAuthClientPendingRequests• radiusAuthClientRoundTripTime• radiusAuthSuccessfullyReceived

Report presents:radiusAuthClient

TimeoutsradiusAuthClientRoundTripTime

radiusAuthClientPendingRequests

radiusAuthSuccessfullyReceived

Nr sec Nr Nr

If MonitoredCounter in:• radiusAuthClientAccessRequests• radiusAuthProcSuccRate

Report presents:

radiusAuthProcSuccRate TotalIncomingPackets

radiusAuthClientAccessRequests

radiusAuthClientRespFailureRate

% Nr Nr %

If MonitoredCounter in:• radiusAuthClientAccessRejects• radiusAuthClientAccessAccepts• radiusAuthClientAccessChallenges• TotalIncomingPackets

Report presents:TotalIncomingPac

ketsradiusAuthClientAccessAccepts

radiusAuthClientAccessRejects

radiusAuthClientAccessChallenges

Nr Nr Nr Nr

Page 230: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

230 E200301-01-214-V10.0I-01

If MonitoredCounter in:• radiusAuthClientRetransRate• radiusAuthClientAccessRetransmissions

Report presents:radiusAuthClient

RetransRateradiusAuthClient

AccessRetransmissions TotalIncomingPackets radiusAuthClientAccessRequests

% Nr Nr Nr

Page 231: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 231

6.4.13 BVC Bar Chart Report

Report Name: BVC Bar Chart Report

Report Short Name: BVCOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek”means the 7previous completedays countingfrom today.

(b) START_DATE Any date(c) END_DATE Any date(d) BVC BSSAP Virtual Connection

Input Parameters:

(e) MonitoredCounter "gbBVCNbrOfLLCFramesUplink""gbBVCNbrOfLLCFramesDownlink""gbBVCNbrOfLLCOctetsUplink""gbBVCNbrOfLLCOctetsDownlink"

The layout of thereport will containdifferentindicatorsaccording to theMonitored counterselected.

Measurements: BVC

Remarks: none

Layout Content:

If MonitoredCounter in:• gbBVCNbrOfLLCFramesUplink• gbBVCNbrOfLLCFramesDownlink• gbBVCNbrOfLLCOctetsUplink• gbBVCNbrOfLLCOctetsDownlink

Report presents:gbBVCNbrOfLLC

FramesUplinkgbBVCNbrOfLLCFramesDownlink

gbBVCNbrOfLLCOctetsUplink

gbBVCNbrOfLLCOctetsDownlink

Pkts/s Pkts/s bps bps

Page 232: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

232 E200301-01-214-V10.0I-01

6.4.14 NSE Bar Chart Report

Report Name: NSE Bar Chart Report

Report Short Name: NSEOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting fromtoday.

(b) START_DATE Any date(c) END_DATE Any date(d) NSE Network Service Entity

Input Parameters:

(e) MonitoredCounter "gbNbrOfResetPerNSE""gbNbrOfSuspendsPerNSE""gbNbrOfResumesPerNSE""gbCumulativeDownTimeperNSE"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: NSE

Remarks: none

Layout Content:

If MonitoredCounter in:• gbNbrOfResetPerNSE• gbNbrOfSuspendsPerNSE• gbNbrOfResumesPerNSE• gbCumulativeDownTimeperNSE

Report presents:gbNbrOfReset

PerNSEgbNbrOfSuspends

PerNSEgbNbrOfResumes

PerNSEgbCumulative

DownTimeperNSENr Nr Nr sec

Page 233: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 233

6.4.15 NSVC Bar Chart Report

Report Name: NSVC Bar Chart Report

Report Short Name: NSVCOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek”means the 7previous completedays countingfrom today.

(b) START_DATE Any date(c) END_DATE Any date(d) NSVC Network Service Virtual

Connection

Input Parameters:

(e) MonitoredCounter "gbNbrOfDiscPduPerNSVC""gbNbrOfResetPerNSVC""gbNbrOfOctetsPerNSVCUplink""gbNbrOfOctetsPerNSVCDownlink"

The layout of thereport will containdifferentindicatorsaccording to theMonitored counterselected.

Measurements: NSVC

Remarks: none

Layout Content:

If MonitoredCounter in:• gbNbrOfDiscPduPerNSVC• gbNbrOfResetPerNSVC• gbNbrOfOctetsPerNSVCUplink• gbNbrOfOctetsPerNSVCDownlink

Report presents:gbNbrOfDiscPdu

PerNSVCgbNbrOfReset

PerNSVCgbNbrOfOctetsPerNSVCUplink

gbNbrOfOctetsPerNSVCDownlink

Nr Nr bps bps

Page 234: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

234 E200301-01-214-V10.0I-01

6.4.16 CAPN Bar Chart Report

Report Name: CAPN Bar Chart Report

Report Short Name: CAPNOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(f) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek”means the 7previous completedays countingfrom today.

(g) START_DATE Any date(h) END_DATE Any date(i) APN Access Point Name

Input Parameters:

(j) MonitoredCounter MSACTIVPDPSSUCCACTVPDPSACTIVEPDPSMSDEACTVPDPS

The layout of thereport will containdifferentindicatorsaccording to theMonitored counterselected.

Measurements: C_GPRSAPN

Remarks: none

Layout Content:

If MonitoredCounter in:• MSACTIVPDPS• SUCCACTVPDPS• ACTIVEPDPS• MSDEACTVPDPSReport presents:

MSACTIVPDPS SUCCACTVPDPS ACTIVEPDPS MSDEACTVPDPS

Nr Nr Nr Nr

Page 235: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 235

6.4.17 CMIB2IFINDEX Bar Chart Report

Report Name: CMIB2IFINDEX Bar Chart Report

Report Short Name: CMIB2IFINDEXOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(k) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek”means the 7previous completedays countingfrom today.

(l) START_DATE Any date(m) END_DATE Any date(n) INTERF Interface Index

Input Parameters:

(o) MonitoredCounter ifInOctetsifOutOctetsifOperStatusifSpeedifInDiscardsifInErrorsifInUnknownProtosifOutDiscardsifOutErrorsifOutQLen

The layout of thereport will containdifferentindicatorsaccording to theMonitored counterselected.

Measurements: C_MIB2INT

Remarks: None

Layout Content:

If MonitoredCounter in:• ifInOctets• ifOutOctets• ifOperStatus• ifSpeedReport presents:

ifInOctets ifOutOctets ifOperStatus ifSpeed

bps bps Nr bps

If MonitoredCounter in:• ifInDiscards• ifInErrors• ifInUnknownProtos

Page 236: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

236 E200301-01-214-V10.0I-01

Report presents:

ifInOctets ifInDiscards ifInErrors ifInUnknownProtos

bps Nr Nr Nr

If MonitoredCounter in:• ifOutOctets• ifOutDiscards• ifOutErrors• ifOutQLenReport presents:

ifOutDiscards ifOutOctets ifOutErrors ifOutQlen

Nr bps Nr Nr

Page 237: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 237

6.4.18 CGGSN Bar Chart Report

Report Name: CGGSN Bar Chart Report

Report Short Name: CGGSNOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(p) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek”means the 7previous completedays countingfrom today.

(q) START_DATE Any date(r) END_DATE Any date(s) INTERF Interface Index

Input Parameters:

(t) MonitoredCounter SentGPDUsRecvGPDUsSentSigMsgsRecvdSigMsgsTotCreatPDPsTotDeletePDPsActiveRejPDPsOutResPDPsUsedBandWDPremMeanThPutNormMeanThPutBeffMeanThPut

The layout of thereport will containdifferentindicatorsaccording to theMonitored counterselected.

Measurements: C_GPRSGTPC_GPRSGGSNC_GPRSQOS

Remarks: None

Layout Content:

If MonitoredCounter in:• SentGPDUs• RecvGPDUs• SentSigMsgs• RecvdSigMsgsReport presents:

SentGPDUs RecvGPDUs SentSigMsgs RecvdSigMsgs

Pkt/s Pkt/s Nr Nr

Page 238: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

238 E200301-01-214-V10.0I-01

If MonitoredCounter in:• TotCreatPDPs• TotDeletePDPs• ActiveRejPDPs• OutResPDPsReport presents:

TotCreatPDPs TotDeletePDPs ActiveRejPDPs OutResPDPs

Nr Nr Nr Nr

If MonitoredCounter in:• UsedBandWD• PremMeanThPut• NormMeanThPut• BeffMeanThPutReport presents:

UsedBandWD PremMeanThPut NormMeanThPut BeffMeanThPut

bps bps bps bps

Page 239: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 239

6.5 VAS Real-Time Repor ts

Page 240: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

240 E200301-01-214-V10.0I-01

6.5.1 MSP Bar Chart Report

Report Name: MSP Bar Chart Report

Report Short Name: MSPOC_BC

Target Groups: Network Operation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek”means the 7previous completedays countingfrom today.

(b) START_DATE Any date(c) END_DATE Any date(d) MSP NE Name

Input Parameters:

(e) MonitoredCounter CCGNOTDEFUSRAGNOAGFROMAUTHSRVNOAGINIPRANGESPERFCLASSNOTDEFUNAGFROMAUTHSRV

The layout of thereport will containdifferentindicatorsaccording to theMonitored counterselected.

Measurements: MSPSERVICE

Remarks: none

Layout Content:

If MonitoredCounter is:

• CCGNOTDEFUSRAG

Report presents:

CCGNOTDEFUSRAG NOAGFROMAUTHSRV NOAGINIPRANGES PERFCLASSNOTDEF

Nr Nr Nr Nr

Page 241: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 241

If MonitoredCounter is:

• NOAGFROMAUTHSRV

Report presents:

NOAGFROMAUTHSRV NOAGINIPRANGES PERFCLASSNOTDEF UNAGFROMAUTHSRV

Nr Nr Nr Nr

If MonitoredCounter is:

• NOAGINIPRANGES

Report presents:

NOAGINIPRANGES PERFCLASSNOTDEF UNAGFROMAUTHSRV CCGNOTDEFUSRAG

Nr Nr Nr Nr

If MonitoredCounter is:

• PERFCLASSNOTDEF

Report presents:

PERFCLASSNOTDEF UNAGFROMAUTHSRV CCGNOTDEFUSRAG NOAGFROMAUTHSRV

Nr Nr Nr Nr

If MonitoredCounter is:

• UNAGFROMAUTHSRV

Report presents:

UNAGFROMAUTHSRV CCGNOTDEFUSRAG NOAGFROMAUTHSRV NOAGINIPRANGES

Nr Nr Nr Nr

Page 242: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

242 E200301-01-214-V10.0I-01

6.6 GERAN Real-Time Reports

Page 243: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 243

6.6.1 BTS Monitoring Panel Report

Report Name: BTS Monitoring Panel Report

Report Short Name: GCell_report

Target Groups: Network Operation, Network Optimisation

Description: The Geran Cell monitoring panel provides a network overview about criticalvalues on the most representative performance indicators of the BTS. Thoseindicators are the TCH drops per Erlang-hour (TCHDropErlh), the call setupsuccess rate (CSSuccRate), the TCH loss rate due to lack of radio resources(TCHLossRate), the handover drop rate (HODropRate) and the total trafficcarried expressed in Erlangs (TCHTraffCarrDR).The pre-defined report launched from the monitoring panel selects its outputdata restricting the evaluation period to the maximum value ofTCHTraffCarrDR, and including only objects for which at least oneperformance indicator violated its threshold according to the respectivecritical condition.

Name Possible Values Remarks

(a) condition_CSSuccRate

Any value ≥0 and≤100

CSSuccRate Threshold.Critical condition: "<"Default = 95%

(b) condition_TCHDropErlh

Any value ≥0 TCHDropErlh Threshold.Critical condition: ">"Default = 0.5

(c) condition_TCHLossRate

Any value ≥0 and≤100

TCHLossRate Threshold.Critical condition: ">"Default = 1%

(d) condition_HODropRate

Any value ≥0 and≤100

HODropRate Threshold.Critical condition: ">"Default = 2%

Input Parameters:

(e) condition_TCHTraffCarrDR

Any value ≥0 TCHTraffCarrDRThreshold.Critical condition: "="Default = 0Erl

Measurements: From SCANBTS functional group:ATIMASCAATSDCMBSMEBUSTCHNACSUCPRNMSGDISQNRFLSDCCNRFLTCHNSUCCHPCSINTHINTSUIMASCATACCBPROTASSATTTASSFAILTASSSUCCUNIHIALCUNIHIRLC

From SCANBTSOHON functional group:ATINBHDO

Page 244: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

244 E200301-01-214-V10.0I-01

NRUNINHDSUINBHDO

Remarks: none

Layout:

BTS Monitoring Panel ReportStart Date: <START_DATE>

End Date: <END_DATE>

CSSuccRate TCHDropErlh TCHLossRate HODropRate TCHTraffCarrDR

% Nr % % ErlDate Time Object

>95 <0.5 <1 <2 >0

YYYY

-MM

-DD

HH

:mm

<Utra

n C

ell I

d>

<CSS

uccR

ate>

<TC

HD

ropE

rlh>

<TC

HLo

ssR

ate>

<HO

Dro

pRat

e>

<TC

HTr

affC

arrD

R>

Page 245: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 245

6.6.2 BTS Bar Chart Report

Report Name: BTS Bar Chart Report

Report Short Name: BTSOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Input Parameters: Name Possible Values Remarks

(a) MonitoredCounter "defTch""TCHEffDR""TCHLossRateWSDR""avgWaitingTime""TCHLossRateDR""TCHTrafCarrDR""TCHMHTDR""CSSuccRateBSS""CSSucc""SuccDirRetry""HOSuccRate""HODropRate""ImpHORate""TCHDropRate""TCHDrop""MTBTCHDrop""TCHDropErlh""defSdcch""SDCCHEff""SDCCHLossRate""SDCCHTrafCarr""SDCCHMHT""ImmAssSuccRate""ImmAssSucc""ImmAssAtt""sdcchActFailRate""sdcchActAtt""sdcchHOSuccRate""sdcchHOAtt""SDCCHDropRate""SDCCHDrop""MTBSDCCHDrop""SDCCHDropErlh""IntraCellHOSuccRate""InterBSCHOSuccRate""InterCellHOSuccRate""IntraCellHOSucc""InterBSCHOSucc""InterCellHOSucc""IntraCellHOAtt""InterBSCHOAtt"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Page 246: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

246 E200301-01-214-V10.0I-01

"InterCellHOAtt""IntraCellHODrop""InterBSCHODrop""InterCellHODrop""HODrop""HOAtt""AssSuccRate""QueFailRate""QueFail""AssAtt""PDAccSuccRate""PAccRejConUL""PAccRejConDL""MeanPDCHConf""MeanUserDataULGb""MeanSigDataULGb""MeanDataULGb""MeanUserDataDLGb""MeanSigDataDLGb""MeanDataDLGb""MeanUserDataULUm""MeanSigDataULUm""MeanDataULUm""MeanUserDataDLUm""MeanSigDataDLUm""MeanDataDLUm""TCHLoss""TCHLossRate""HOIndRejRate""HOIndRejections""MeanDataThrGb"

(b) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(c) START_DATE Any date

(d) END_DATE Any date

(e) BTS Cell Symbolic Name

Measurements: From SCANBTSOHON functional group:ATINBHDONRUNINHDSUINBHDO

All scanners from SCANBTS functional group, with the following exceptions:AMRCHDISMBTCHAMRMEITCHIBNAVTCHSDNDFTCHSDNNNOTNCHNTCHSDCMTASSATVSTASSUCVSTNMSCNCLTNSUDHSC

All scanners from SCANBTSGPRS functional group.

Remarks: none

Page 247: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 247

Layout Content:

If MonitoredCounter in:• TCHEffDR

Report presents:TCHEffDR defTch TCHTrafCarrDR CSSuccRateBSS

% Nr Erl %

If MonitoredCounter in:• TCHLossRateWSDR• avgWaitingTime

Report presents:TCHLossRateWSDR defTch TCHTrafCarrDR avgWaitingTime

% Nr Erl sec

If MonitoredCounter in:• TCHLossRateDR• defTch• TCHMHTDR• TCHTrafCarrDR

Report presents:TCHLossRateDR defTch TCHTrafCarrDR TCHMHTDR

% Nr Erl sec

If MonitoredCounter in:• CSSuccRateBSS

Report presents:CSSuccRateBSS ImmAssSuccRate AssSuccRate SDCCHDropRate

% % % %

If MonitoredCounter in:• CSSucc• SuccDirRetry

Report presents:SuccDirRetry CSSucc TCHTrafCarrDR TCHLossRateDR

Nr Nr Erl %

If MonitoredCounter in:• HOSuccRate

Report presents:HOSuccRate IntraCellHOSuccRate InterBSCHOSuccRate InterCellHOSuccRate

% % % %

Page 248: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

248 E200301-01-214-V10.0I-01

If MonitoredCounter in:• HODropRate• TCHDropRate• HODrop• TCHDrop

Report presents:HODropRate HODrop TCHDropRate TCHDrop

% Nr % Nr

If MonitoredCounter in:• ImpHORate

Report presents:ImpHORate HODropRate TCHDropErlh SDCCHDropErlh

% % Nr Nr

If MonitoredCounter in:• MTBTCHDrop

Report presents:MTBTCHDrop CSSucc TCHDrop TCHTrafCarrDR

sec Nr Nr Erl

If MonitoredCounter in:• TCHDropErlh

Report presents:TCHDropErlh CSSucc TCHDrop HODrop

Nr Nr Nr Nr

If MonitoredCounter in:• SDCCHEff

Report presents:SDCCHEff defSdcch SDCCHTrafCarr ImmAssSuccRate

% Nr Erl %

If MonitoredCounter in:• defSdcch• SDCCHLossRate• SDCCHTrafCarr• SDCCHMHT

Report presents:SDCCHLossRate defSdcch SDCCHTrafCarr SDCCHMHT

% Nr Erl sec

Page 249: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 249

If MonitoredCounter in:• ImmAssSuccRate• ImmAssAtt

Report presents:ImmAssSuccRate ImmAssAtt sdcchActFailRate SDCCHLossRate

% Nr % %

If MonitoredCounter in:• sdcchActFailRate• sdcchActAtt• sdcchHOSuccRate• sdcchHOAtt

Report presents:sdcchActFailRate sdcchHOSuccRate sdcchHOAtt sdcchActAtt

% % Nr Nr

If MonitoredCounter in:• SDCCHDropRate• SDCCHDrop• SDCCHDropErlh

Report presents:SDCCHDropRate SDCCHDrop SDCCHDropErlh ImmAssSucc

% Nr Nr Nr

If MonitoredCounter in:• ImmAssSucc• MTBSDCCHDrop

Report presents:MTBSDCCHDrop ImmAssSucc SDCCHDrop SDCCHTrafCarr

sec Nr Nr Erl

If MonitoredCounter in:• IntraCellHOAtt• IntraCellHODrop• IntraCellHOSuccRate

Report presents:IntraCellHOSuccRate HOAtt IntraCellHOAtt IntraCellHODrop

% Nr Nr Nr

If MonitoredCounter in:• InterBSCHOAtt• InterBSCHODrop• InterBSCHOSuccRate

Report presents:InterBSCHOSuccRate HOAtt InterBSCHOAtt InterBSCHODrop

% Nr Nr Nr

Page 250: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

250 E200301-01-214-V10.0I-01

If MonitoredCounter in:• InterCellHOAtt• InterCellHODrop• InterCellHOSuccRate

Report presents:InterCellHOSuccRate HOAtt InterCellHOAtt InterCellHODrop

% Nr Nr Nr

If MonitoredCounter in:• IntraCellHOSucc

Report presents:IntraCellHOSucc IntraCellHOSuccRate HOIndRejRate IntraCellHOAtt

Nr % % Nr

If MonitoredCounter in:• InterBSCHOSucc

Report presents:InterBSCHOSucc InterBSCHOSuccRate HOIndRejRate InterBSCHOAtt

Nr % % Nr

If MonitoredCounter in:• InterCellHOSucc

Report presents:InterCellHOSucc InterCellHOSuccRate HOIndRejRate InterCellHOAtt

Nr % % Nr

If MonitoredCounter in:• AssAtt• AssSuccRate

Report presents:AssSuccRate AssAtt TCHLossRate QueFailRate

% Nr % %

If MonitoredCounter in:• QueFail• QueFailRate

Report presents:QueFailRate QueFail defTch TCHTrafCarrDR

% Nr Nr Erl

Page 251: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 251

If MonitoredCounter in:• PDAccSuccRate• PAccRejConUL• PAccRejConDL• MeanPDCHConf

Report presents:PDAccSuccRate PAccRejConUL PAccRejConDL MeanPDCHConf

% Nr Nr Nr

If MonitoredCounter in:• MeanSigDataULGb• MeanDataULGb• MeanUserDataULGb

Report presents:MeanUserDataULGb MeanSigDataULGb MeanDataULGb PDAccSuccRate

kbps kbps kbps %

If MonitoredCounter in:• MeanSigDataDLGb• MeanDataDLGb• MeanUserDataDLGb

Report presents:MeanUserDataDLGb MeanSigDataDLGb MeanDataDLGb PDAccSuccRate

kbps kbps kbps %

If MonitoredCounter in:• MeanUserDataULUm

Report presents:MeanUserDataULUm MeanUserDataULGb PAccRejConUL MeanPDCHConf

kbps kbps Nr Nr

If MonitoredCounter in:• MeanSigDataULUm

Report presents:MeanSigDataULUm MeanSigDataULGb PAccRejConUL MeanPDCHConf

kbps kbps Nr Nr

If MonitoredCounter in:• MeanDataULUm

Report presents:MeanDataULUm MeanDataULGb PAccRejConUL MeanPDCHConf

kbps kbps Nr Nr

Page 252: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

252 E200301-01-214-V10.0I-01

If MonitoredCounter in:• MeanUserDataDLUm

Report presents:MeanUserDataDLUm MeanUserDataDLGb PAccRejConDL MeanPDCHConf

kbps kbps Nr Nr

If MonitoredCounter in:• MeanSigDataDLUm

Report presents:MeanSigDataDLUm MeanSigDataDLGb PAccRejConDL MeanPDCHConf

kbps kbps Nr Nr

If MonitoredCounter in:• MeanDataDLUm

Report presents:MeanDataDLUm MeanDataDLGb PAccRejConDL MeanPDCHConf

kbps kbps Nr Nr

If MonitoredCounter in:• TCHLossRate• TCHLoss

Report presents:TCHLossRate TCHTrafCarrDR defTch TCHLoss

% Erl Nr Nr

If MonitoredCounter in:• HOAtt• HOIndRejections• HOIndRejRate

Report presents:HOIndRejRate HOAtt HOIndRejections TCHDropErlh

% Nr Nr Nr

If MonitoredCounter in:• MeanDataThrGb• SDCCHLossRate• SDCCHTrafCarr• SDCCHMHT

Report presents:MeanDataThrGb MeanDataDLGb MeanDataULGb MeanPDCHConf

kbps kbps kbps Nr

Page 253: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 253

6.6.3 TRX Bar Chart Report

Report Name: TRX Bar Chart Report

Report Short Name: TRXOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) TRX TRX Id

Input Parameters:

(e) MonitoredCounter "TRXAvail" The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: From SCANTRX functional group:TRANAVTI

Remarks: none

Layout Content:

If MonitoredCounter in:• TRXAvail

Report presents:TRXAvail

%

Page 254: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

254 E200301-01-214-V10.0I-01

6.6.4 BSC Bar Chart Report

Report Name: BSC Bar Chart Report

Report Short Name: BSCOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) BSC BSC Symbolic Name

Input Parameters:

(e) MonitoredCounter "MPPCLoad""TDPCLoad"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: From SCANBSC functional group:BSCPRCLD

Remarks: none

Layout Content:

If MonitoredCounter in:• TDPCLoad• MPPCLoad

Report presents:TDPCLoad MPPCLoad

% %

Page 255: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 255

6.6.5 BTSM Bar Chart Report

Report Name: BTSM Bar Chart Report

Report Short Name: BTSMOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) BTSM BTSM Symbolic Name

Input Parameters:

(e) MonitoredCounter "BTSEPRLD" The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: From SCANBTSM functional group:BTSEPRLD

Remarks: none

Layout Content:

If MonitoredCounter in:• BTSEPRLD

Report presents:BTSEPRLD

%

Page 256: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

256 E200301-01-214-V10.0I-01

6.7 UTRAN Real-Time Reports

Page 257: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 257

6.7.1 UCELL Monitoring Panel Report

Report Name: UCELL Monitoring Panel Report

Report Short Name: ucell_report

Target Groups: Network Operation, Network Optimisation

Description: The Utran Cell monitoring panel provides a network overview about criticalvalues on the most representative performance indicators of the Utran cell,which are the Cell Load per Spreading Factor (CELLLOADPSF), the CallSetup Success Rate (CSSR), the Connection drop Rate (ConDR) and theBranch Addition Success Rate (BranchAddSR).The pre-defined report launched from the monitoring panel selects its outputdata restricting the evaluation period to the maximum value ofCELLLOADPSF, and including only objects for which at least oneperformance indicator violated its threshold according to the respectivecritical condition.

Name Possible Values Remarks

(a) condition_CELLLOADPSF

Any value ≥0 and≤100

CELLLOADPSF Threshold.Critical condition: ">"Default = 80%

(b) condition_CSSRAccProb

Any value ≥0 and≤100

CSSRAccProb Threshold.Critical condition: "<"Default = 90%

(c) condition_ConDR Any value ≥0 and≤100

ConDR Threshold.Critical condition: ">"Default = 5%

Input Parameters:

(d) condition_BranchAddSR

Any value ≥0 and≤100

BranchAddSR Threshold.Critical condition: "<"Default = 80%

Measurements: From RNC:uuCodesUsedrabEstabAttrabEstabSuccrrcEstabAttrrcEstabSuccshoAddIntraNodeBAttshoAddIntraNodeBSuccshoAddIntraRncAttshoAddIntraRncSuccshoAddInterRncAttshoAddInterRncSucciuRelCmdiuRelReq

Remarks: none

Page 258: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

258 E200301-01-214-V10.0I-01

Layout:

UCELL Monitoring Panel ReportStart Date: <START_DATE>

End Date: <END_DATE>

CELLLOADPSF CSSRAccProb ConDR BranchAddSR

% % % %Date Time Object

<80 >90 <5 >80

YYYY

-MM

-DD

HH

:mm

<Utra

n C

ell I

d>

<CEL

LLO

ADPS

F>

<CSS

RAc

cPro

b>

<Con

DR

>

<Bra

nchA

ddSR

>

Page 259: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 259

6.7.2 RNC Monitoring Pane l Report

Report Name: RNC Monitoring Panel Report

Report Short Name: RNCProc_report

Target Groups: Network Operation, Network Optimisation

Description: The RNC Processor Load Monitoring panel provides an overview about theload on the RNC processors.The pre-defined report launched from the monitoring panel selects its outputdata restricting the evaluation period to the maximum value ofPRLCUSAGE_MEA, and including only objects for which at least oneperformance indicator violated its threshold according to the respectivecritical condition.

Name Possible Values Remarks

(a) condition_PRLCUSAGE_MEA

Any value ≥0 and≤100

PRLCUSAGE_MEAThreshold.Critical condition: ">"Default = 70%

(b) condition_PRLCAllocSR

Any value ≥0 and≤100

PRLCAllocSR Threshold.Critical condition: "<"Default = 95%

(c) condition_DHTUSAGE_MEA

Any value ≥0 and≤100

DHTUSAGE_MEAThreshold.Critical condition: ">"Default = 70%

Input Parameters:

(d) condition_DHTAllocSR

Any value ≥0 and≤100

DHTAllocSR Threshold.Critical condition: "<"Default = 95%

Measurements: From RNC:dhtUsagedhtAllocAttdhtAllocSuccprlcUsageprlcAllocAttprlcAllocSucc

Remarks: none

Page 260: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

260 E200301-01-214-V10.0I-01

Layout:

RNC Monitoring Panel ReportStart Date: <START_DATE>

End Date: <END_DATE>

PRLCUSAGE_MEA PRLCAllocSR DHTUSAGE_MEA DHTAllocSR

% % % %Date Time Object

<70 >95 <70 >95

YYYY

-MM

-DD

HH

:mm

<Utra

n C

ell I

d>

<PR

LCU

SAG

E_M

EA>

<PR

LCAl

locS

R>

<DH

TUSA

GE_

MEA

>

<DH

TAllo

cSR

>

Page 261: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 261

6.7.3 UCELL Bar Chart Report

Report Name: UCELL Bar Chart Report

Report Short Name: UCELLOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) MonitoredCounter "CSSRAccProb""CSSRConv""MHTConv""CSSRStream""MHTStream""CSSRInter""MHTInter""CSSRBackg""MHTBackg""ConDR""ConD""UnNormalConRR""UnNormalCR""SHORate_1""BranchAddSR""HHOSRIntraNB""CELLLOADPSF""PCHDISCRATE""FACHDISCRATE""RRCEstabAtt""RRCEstabAttConv""RRCEstabAttStrem""RRCEstabAttInter""RRCEstabAttBackg""SHOSucc""HHOSucc""SHOAtt""HHOAtt""RABEstabSucc""FACHUSAGE""PCHUSAGE""CodesUsed""CodeAllocSR""IuReleases"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

(b) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(c) START_DATE Any date

Input Parameters:

(d) END_DATE Any date

Page 262: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

262 E200301-01-214-V10.0I-01

(e) UCELL UTRAN Cell SymbolicName

Measurements: From RNC:hhoAllOutAtthhoAllOutFailhhoAllOutSucciuRelCmdiuRelReqrabEstabAttrabEstabFailrabEstabSuccrabPerQosClassrabRelrrcEstabAttrrcEstabSuccshoAddIntraNodeBAttshoAddIntraNodeBSuccshoAddInterRncAttshoAddInterRncSuccshoAddIntraRncAttshoAddIntraRncSuccuesPerActiveLinkSetSizeuuCodesUseduuCodeReqAttuuCodeReqSuccpchUsageRatepchDiscardRatefachUsageRatefachDiscardRate

Remarks: none

Layout Content:

If MonitoredCounter in:• CSSRAccProb• RRCEstabAtt• RABEstabSucc

Report presents:CSSRAccProb RRCEstabAtt RABEstabSucc CELLLOADPSF

% Nr Nr %

If MonitoredCounter in:• CSSRConv• MHTConv• RRCEstabAttConv

Report presents:CSSRConv RRCEstabAttConv MHTConv CELLLOADPSF

% Nr sec %

Page 263: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 263

If MonitoredCounter in:• CSSRStream• MHTStream• RRCEstabAttStrem

Report presents:CSSRStream RRCEstabAttStream MHTStream CELLLOADPSF

% Nr sec %

If MonitoredCounter in:• CSSRInter• MHTInter• RRCEstabAttInter

Report presents:CSSRInter RRCEstabAttInter MHTInter CELLLOADPSF

% Nr sec %

If MonitoredCounter in:• CSSRBackg• MHTBackg• RRCEstabAttBackg

Report presents:CSSRBackg RRCEstabAttBackg MHTBackg CELLLOADPSF

% Nr sec %

If MonitoredCounter in:• ConDR• ConD

Report presents:ConDR IuReleases ConD CELLLOADPSF

% Nr Nr %

If MonitoredCounter in:• UnNormalConRR• UnNormalCR• IuReleases

Report presents:UnNormalConRR IuReleases UnNormalCR CELLLOADPSF

% Nr Nr %

If MonitoredCounter in:• SHORate_1

Report presents:SHORate_1 BranchAddSR RABEstabSucc CELLLOADPSF

% % Nr %

Page 264: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

264 E200301-01-214-V10.0I-01

If MonitoredCounter in:• BranchAddSR• SHOSucc• SHOAtt

Report presents:BranchAddSR SHOAtt SHOSucc CELLLOADPSF

% Nr Nr %

If MonitoredCounter in:• HHOSRIntraNB• HHOSucc• HHOAtt

Report presents:HHOSRIntraNB HHOAtt HHOSucc CELLLOADPSF

% Nr Nr %

If MonitoredCounter in:• CELLLOADPSF• CodesUsed• CodeAllocSR

Report presents:CELLLOADPSF CodesUsed CodeAllocSR CSSRAccProb

% Nr % %

If MonitoredCounter in:• PCHDISCRATE• FACHDISCRATE• FACHUSAGE• PCHUSAGE

Report presents:PCHDISCRATE FACHUSAGE PCHUSAGE FACHDISCRATE

% % % %

Page 265: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 265

6.7.4 RNC Bar Chart Report

Report Name: RNC Bar Chart Report

Report Short Name: RNCOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) RNC RNC ID

Input Parameters:

(e) MonitoredCounter "PRLCUSAGE_MEA""DHTUSAGE_MEA""DHTAllocSR""PRLCAllocSR""PRLCBUSYTIME""DHTBUSYTIME""PRLCBUSYRATE""DHTBUSYRATE"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: From RNC:dhtUsagedhtBusyTimedhtAllocAttdhtAllocSuccprlcUsageprlcBusyTimeprlcAllocAttprlcAllocSucc

Remarks: none

Page 266: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

266 E200301-01-214-V10.0I-01

Layout Content:

If MonitoredCounter in:• PRLCUSAGE_MEA• PRLCAllocSR• PRLCBUSYTIME• PRLCBUSYRATE

Report presents:PRLCUSAGE_MEA PRLCBUSYTIME PRLCBUSYRATE PRLCAllocSR

% sec % %

If MonitoredCounter in:• DHTUSAGE_MEA• DHTAllocSR• DHTBUSYTIME• DHTBUSYRATE

Report presents:

DHTUSAGE_MEA DHTBUSYTIME DHTBUSYRATE DHTAllocSR

% sec % %

Page 267: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 267

6.7.5 STM1LINE Bar Chart Report

Report Name: STM1LINE Bar Chart Report

Report Short Name: STM1LINEOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) STM1LINE STM1 Physical Line

Input Parameters:

(e) MonitoredCounter "STMLDiscCellsCong""STMLDiscCongRate""STM1TxUsageRate""STM1RxUsageRate"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: From RNC:discardedCellsCongestionlineIncomingCellslineOutgoingCells

Remarks: none

Layout Content:

If MonitoredCounter in:• STMLDiscCellsCong• STMLDiscCongRate• STM1TxUsageRate• STM1RxUsageRate

Report presents:STMLDiscCellsCong STM1TxUsageRate STM1RxUsageRate STMLDiscCongRate

Nr % % %

Page 268: Spots 10.0 Performance Reports

Siemens SA Siemens Performance Reports (SPOTS V10 Drop 4)

268 E200301-01-214-V10.0I-01

6.7.6 E1LINE Bar Chart Report

Report Name: E1LINE Bar Chart Report

Report Short Name: E1LINEOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) E1LINE E1 Physical Line

Input Parameters:

(e) MonitoredCounter "ELTxRate""ELOutCells""ELIncCells"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: From RNC:lineIncomingCellslineOutgoingCellsdiscardedCellsHecViolation

Remarks: none

Layout Content:

If MonitoredCounter in:• ELTxRate• ELOutCells• ELIncCells

Report presents:ELTxRate ELIncCells ELOutCells

kbps Nr Nr

Page 269: Spots 10.0 Performance Reports

Siemens Performance Reports (SPOTS V10 Drop 4) Siemens SA

E200301-01-214-V10.0I-01 269

6.7.7 STM1VP Bar Chart Report

Report Name: STM1VP Bar Chart Report

Report Short Name: STM1VPOC_BC

Target Groups: Network Operation, Network Optimisation

Description: This report receives as input parameter the name of a performance indicator(the "MonitoredMetric"). The name must be selected from the list of PossibleValues for the input parameter "MonitoredMetric".The report then returns a time evolution for the "MonitoredMetric" and otherrelated indicators. The related indicators are a pre-defined set assigned toeach "MonitoredMetric". The Layout Content field of this description providesthe correspondence between "MonitoredMetric" name and related set ofperformance indicators.

Name Possible Values Remarks

(a) PERIOD_KEYWORD "Today""Yesterday""Lastweek"

“Lastweek” meansthe 7 previouscomplete dayscounting from today.

(b) START_DATE Any date(c) END_DATE Any date(d) STM1VP STM1 Virtual Path Code

Input Parameters:

(e) MonitoredCounter "STMVPCong""STMVPCellLossRatio""STMVPOutCells""STMVPIncCells"

The layout of thereport will containdifferent indicatorsaccording to theMonitored counterselected.

Measurements: From RNC:vpvcIncomingCellsvpvcOutgoingCellscellLossRatiocongestionOfVP

Remarks: none

Layout Content:

If MonitoredCounter in:• STMVPCong• STMVPCellLossRatio• STMVPOutCells• STMVPIncCells

Report presents:STMVPCong STMVPOutCells STMVPIncCells STMVPCellLLossRatio

% Nr Nr %