spo2 for neonates tl-535u, tl-273t3 - nihon kohden · pdf filereused for length of...

2
Proven Accuracy 1 Nihon Kohden commissioned two studies to evaluate pulse oximetry probes at the esteemed Hypoxia Research Laboratory at The University of California, San Francisco in 2008 and 2010. 1 All tested probes meet the accuracy specifications and exceed the ISO 80601-2-61: 2011 specification for SpO 2 probe accuracy. 1 ACCURACY CRITERIA FOR SpO 2 MEASUREMENT SpO 2 for Neonates TL-535U, TL-273T3 Care for Your Tiniest Patients us.nihonkohden.com Different Thinking for Better Healthcare. ® Probe TL-535U Result for TL-535U Bias (SpO 2 -SaO 2 ) Analysis Hemoximeter SaO 2 Range 70 – 80% 80 – 100% Count 162 356 Mean 0.72% 0.03% Standard Deviation 1.88% 1.37% Root Mean Square (RMS) 2.01% 1.37% ISO 80601-2-61: 2011 3% or less 2% or less

Upload: buinhan

Post on 19-Feb-2018

216 views

Category:

Documents


2 download

TRANSCRIPT

Proven Accuracy 1Nihon Kohden commissioned two studies to evaluate pulse oximetry probes at the esteemed Hypoxia Research Laboratory at The University of California, San Francisco in 2008 and 2010.1 All tested probes meet the accuracy specifications and exceed the ISO 80601-2-61: 2011 specification for SpO2 probe accuracy.1

ACCURACY CRITERIA FOR SpO2 MEASUREMENT

SpO2 for Neonates TL-535U, TL-273T3

Care for Your TiniestPatients

us.nihonkohden.com Different Thinking for Better Healthcare.®

Probe TL-535U

Result for TL-535U Bias (SpO2-SaO2) Analysis

Hemoximeter SaO2 Range 70 – 80% 80 – 100%

Count 162 356

Mean 0.72% 0.03%

Standard Deviation 1.88% 1.37%

Root Mean Square (RMS) 2.01% 1.37%

ISO 80601-2-61: 2011 3% or less 2% or less

SpO2 for NeonatesTL-535U, TL-273T3

References 1 INTERNAL: SpO2 Monitoring Pulse Oximeter Accuracy Study, 2008 study by John R. Feiner, M.D., Phillip E. Bickler, Ph.D.M.D., and John W. Severinghaus, M.D. For the 2010 study, authors are Phillip E. Bickler, Ph.D.M.D. and John R. Feiner, M.D. at the Hypoxia Research Laboratory at the University of California, San Francisco.

THIS DATA SHEET MAY BE REVISED OR REPLACED BY NIHON KOHDEN AT ANY TIME WITHOUT NOTICE.

us.nihonkohden.com

MMLB 149[A]-CO-1253

NIHON KOHDEN AMERICA, INC. | 15353 BARRANCA PARKWAY, IRVINE, CA 92618

800.325.0283 | 949.580.1555 | FAX: 949.580.1550 | EMAIL: [email protected]

Comfortable Patients Simplifies Clinical WorkflowTL-535U:

• Attachment wrap uses soft foam where it touches baby’s skin

• No Adhesive – Attachment wrap uses supremely soft Velcro®-style closure

• Sensor feels like soft felt, designed so sensor cord doesn’t leave indentation on baby’s delicate skin

• TL-535U Semi-Disposable Sensor can be reused for length of baby’s stay in NICU, simply change the wrap to freshen

• TL-273T3 uses traditional soft adhesive

• Neonate SpO2 options depending on patient needs, choose traditional adhesive or non-adhesive sensors for more sensitive patients

• Neonatal Dual-SpO2 for detecting duct dependent congenital heart diseases in the newborn – dual SpO2 is simplified with the Nihon Kohden Smart Cable™ – just plug and measure

Velcro is a registered trademark of Velcro BVBA.

Smart Cable is a trademark of Nihon Kohden Coorporation.

Different Thinking for Better Healthcare is a registered trademark of Nihon Kohden.

5 SpO2 sensors, each has 3 size S attachment wraps

24

24

1

1

1

24

1

1

Neonate Soft Sensor

Attachment Wrap Size S

Attachment Wrap Size L

Connection Cable 0.3m for TL-535U Sensor

Connection Cable 1m for TL-535U Sensor

SpO2 Cable 3m for TL-535U

Neonate Adhesive SpO2

SpO2 for TL-273T3 or Connection Cord for

TL-535U

Dual SpO2 for TL-273T3 or Connection Cord

for TL-535U

TL-535U

YS-102P0

YS-102P1

JL-030U1

JL-030U2

JL-930P

TL-273T3

JL-900P

JL-500P1

ITEM PART NUMBER QUANTITY

① YS-102P0: Small Attachment Wrap② YS-102P1: Large Attachment Wrap③ TL-535U Sensor: Neonate Semi-Disposable Non-Adhesive④ TL-273T3: Neonate Adhesive-Style SpO2 Probe ⑤ JL-930P: SpO2 Cable for TL-535U, 3m⑥ JL-030U1: Connection Cable for TL-535U, 0.3m⑦ JL-900P: SpO2 Cable for TL-273T3 or Connection Cable for TL-535U⑧ JL-500P1: Dual SpO2 Cable for TL-273T3 or Connection Cable for TL-535U

④ ⑤

SpO2 for Neonates Product Line