split system heat pump product & performance data system heat pump product & performance...

14
Split System Heat Pump Product & Performance Data XL16i 4TWX6024,036,048 & 060B 2,3,4 & 5 Tons PUB. NO. 22-1754-05A SS-PRC007-EN

Upload: doankhanh

Post on 06-Apr-2018

221 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

Split SystemHeat Pump Product& Performance Data

XL16i4TWX6024,036,048 & 060B

2,3,4 & 5 Tons

PUB. NO. 22-1754-05A

SS-PRC007-EN

Page 2: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

© 2009 Trane 2 22-1754-05A

GeneralFeatures

Split System Heat Pump Units . . .The Evolution ContinuesXL to XLi

technology, and customer research todevelop the next generation of leadershipproducts.

Couple the Trane reputation for reliabilityand durability with the above mentionedmission and accomplishments and youcontinue to have systems that prove“It’s Hard to Stop a Trane®. ”

4TWX6 split systems represent a productthat is not only an engineer’s dream, it'salso a customer’s dream. The designteam’s mission and accomplishment isenhanced performance and efficiency,improved reliability and durability, andimproved installability and serviceability.

Trane’s experienced design team applied“six sigma principles”, the latest computer

Page 3: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

22-1754-05A 3

Contents

General Features 2

Features and Benefits 4Optional Equipment 5Low Outdoor Ambient Cooling 5A.R.I. Standard Capacity Rating Conditions 5

Selection Procedure 6Model Number Nomenclature 6

General Data 74TWX6024A1000A 74TWX6036A1000A 84TWX6048A1000A 94TWX6060A1000A 10

Electrical Data 11

Dimensions 13

Mechanical Specification Options 14

Page 4: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

4 22-1754-05A

Features andBenefits

• Climatuff® staged scroll compressor

• Efficiency up to 17.0 SEER and9.85 HSPF

• All aluminum Spine Fin™ coil

• WeatherGuard™ II top shields unit

• DuraTuff™ base, fast complete drain,weather proof

• WeatherGuard™ fasteners

• XL Seacoast shield

• Industry leading appearance

• Tarpaulin gray cabinet withanthracite gray top

• Low sound ratings

• Compresssor sound insulator

• Multi-stage fan for quiet operation

• Quick-Sess™ cabinet, service accessand refrigerant connections with full coilprotection

• Demand Defrost Control withDiagnostics

• Glossy corrosion resistant finish

• Internal high/low pressure &temperature protection

• High pressure switch

• All models have designed startability

• 060 ship with start kit

• Liquid line filter-drier

• Comfort “R”™ mode approved

• Easy single side service

• Multi-use liquid and suction lineservice valves

• Easy top & fan removal

• Full length control and service valvecover

• R-410A refrigerant

• Compresssor sump heat

• Extended warranties available

• S.E.E.T. design testing

• 100% line run test

• Low ambient cooling to 40° F. withAY28X084, 30° F. with TXV

Page 5: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

22-1754-05A 5

Features andBenefits

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. airentering outdoor coil. (B) High Temperature Heating 47°F. D.B., 43°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoorcoil. (C) Low Temperature Heating 17°F. D.B., 15°F. W.B. air entering outdoor coil, 70°F. D.B. air entering indoor coil. (D) Ratedindoor airflow for heating is the same as for cooling.

A.R.I. STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling operation.)Standard Noise Rating number is at 95°F. outdoor air.

Low Outdoor Ambient Cooling

Low Ambient As EvaporatorCooling Manufactured Defrost ControlThermal Expansion Valve (TXV) 55°F 30°F

Optional Equipment

OPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark [✓✓✓✓✓] indicates accessories included).Indoor Thermostats — Elec. Setback Thermostat .................................................................................................. TAYSTAT500C [ ]

Electronic, 3 Htg./2 Clg. (Non Prog.) ..................................................................................... TAYSTAT575 [ ]3/2 HP Stat Electro Mech. ........................................................................................................................................BAY28X153A [ ]Outdoor Thermostats 46°F. to – 10°F. (Adjustable) ................................................................................................. TAYSTAT250B [ ]Evaporator Defrost Control Kit ..................................................................................................................................... AY28X084 [ ]5 Minute Delay Relay 1 ........................................................................................................................................TAYASCT501A [ ]Outdoor Temperature Sensor (TAYSTAT500C) ...................................................................................................... TAYSENS100A [ ]Snow Legs – Base and Cap 4" High ....................................................................................................................... BAYLEGS002 [ ]Snow Legs – addition 4" extension (used with BAYLEGS002) ................................................................................ BAYLEGS003 [ ]Start Kit (2.5-4 ton models) ..................................................................................................................................... BAYKSKT260 [ ]Extreme Conditions Mounting Kit ........................................................................................................................... BAYECMT001 [ ]1 Do not use with programmable thermostats

BRAZED TUBING REFRIGERANT LINE SETS (All Suction Lines are Insulated.)1/2" ODM (90° bend, one end), 1/2" and 1/4" tubing ............................................................................................ TAYREFLN5__* [ ]5/8" ODM (90° bend, one end), 5/8" and 5/16" tubing .......................................................................................... TAYREFLN6__* [ ]3/4" ODM (90° bend, one end), 3/4" and 3/8" tubing ............................................................................................ TAYREFLN7__* [ ]3/4" ODM (90° bend, one end), 3/4" and 5/16" tubing .......................................................................................... TAYREFLN2__* [ ]7/8" ODM (90° bend, one end), 7/8" and 3/8" tubing ............................................................................................ TAYREFLN3__* [ ]* Line lengths: 15, 20, 25, 30, 40 & 50 ft. Insert desired line length in catalog number at right for the complete number.

Example: TAYREFLN220

Page 6: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

6 22-1754-05A

Refrigerant Type2 = R-224 = R-410A

TRANE

Product TypeW = Split Heat PumpT = Split Cooling

Product FamilyZ = LEADERSHIP - 2 STAGEX = LEADERSHIPR = REPLACEMENT / RETAILB = BASICA = LIGHT COMMERCIAL

Family SEER0 =̃ 10 2 =̃ 12 4 =̃ 141 =̃ 11 3 =̃ 13 6 =̃ 16 8 =̃ 18

Unit PartsIdentifier

Minor DesignModifications

SecondaryFunction

Power Supply1 = 200 - 230 / 1 / 60 or 208 - 230 / 1 / 603 = 200 - 230 / 3 / 604 = 460 / 3 / 60

Major Design Modifications

Nominal Capacity in 000’s of BTU’s

Split System Connections 1 - 6 Tons0 = Brazed

1 2 3 4 5 6 7 8 9 1 0 11 1 2 1 3 1 4 1 5

4 T W X 6 0 3 6 B 1 0 0 0 A A

SelectionProcedure

Model Number Nomenclature

Page 7: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

22-1754-05A 7

OUTDOOR UNIT 12 4TWX6024B1000ASOUND RATING (DECIBELS) 2 77POWER CONNS. — V/PH/HZ 3 230/1/60MIN. BRCH. CIR. AMPACITY 13BR. CIR. MAX. (AMPS) 20PROT. RTG. } MIN. (AMPS) 20COMPRESSOR CLIMATUFF® - SCROLLNO. USED - NO. SPEEDS 1 - 2VOLTS/PH/HZ 230/1/60R.L. AMPS 7 - L.R. AMPS 10.3 - 52FACTORY INSTALLED

START COMPONENTS 8 NOINSULATION/SOUND BLANKET YESCOMPRESSOR HEAT YES

OUTDOOR FAN — TYPE PROPELLERDIA. (IN.) - NO. USED 23 - 1TYPE DRIVE - NO. SPEEDS DIRECT - 2CFM @ 0.0 IN. W.G. 4 2700NO. MOTORS - HP. 1 - 1/15MOTOR SPEED R.P.M. 825VOLTS/PH/HZ 200/230/1/60F.L. AMPS 0.60OUTDOOR COIL — TYPE SPINE FIN™ROWS - F.P.I. 1 - 24FACE AREA (SQ. FT.) 21.20TUBE SIZE (IN.) 5/16REFRIGERANT CONTROL EXPANSION VALVEREFRIGERANT R-410A(O.D. UNIT) NP CHRG. 5 5/12-LB/OZFACTORY SUPPLIED YESLINE SIZE - IN. O.D. GAS 6 5/8LINE SIZE - IN. O.D. LIQ. 6 5/16FCCVRESTRICTOR ORIFICE SIZE N/ADIMENSIONS H X W X DOUTDOOR UNIT CRATED (IN.) 47.6 X 30.1 X 33UNCRATED SEE OUTLINE DWG.WEIGHTSHIPPING (LBS.) 266NET (LBS.) 229

GeneralData 4TWX6024B1000A

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARYHEAT PUMP EQUIPMENT CERTIFICATION PROGRAM, WHICH ISBASED ON A.R.I. STANDARD 210/240.

2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6.3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.

ONLY USE HACR CIRCUIT BREAKERS OR FUSES.4 STANDARD AIR - DRY COIL - OUTDOOR5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT

NAMEPLATE AND SERVICE INSTRUCTION.6 MAX. LINEAR LENGTH: 80 FT. MAX. LIFT - SUCTION 25 FT; MAX LIFT -

LIQUID 25 FT. FOR GREATER LENGTH REFER TO REFRIGERANTPIPING SOFTWARE PUB. NO. 32-3312-01.

7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNITNAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TOCOMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUMFUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUITSELECTION CURRENT.

8 NO MEANS NO START COMPONENTSYES MEANS QUICK START KIT COMPONENTSPTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

SPLIT SYSTEM

Page 8: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

8 22-1754-05A

OUTDOOR UNIT 12 4TWX6036B1000ASOUND RATING (DECIBELS) 2 77POWER CONNS. — V/PH/HZ 3 230/1/60MIN. BRCH. CIR. AMPACITY 24BR. CIR. MAX. (AMPS) 40PROT. RTG. } MIN. (AMPS) 40COMPRESSOR CLIMATUFF® - SCROLLNO. USED - NO. SPEEDS 1 - 2VOLTS/PH/HZ 230/1/60R.L. AMPS 7 - L.R. AMPS 16.7 - 82FACTORY INSTALLED

START COMPONENTS 8 NOINSULATION/SOUND BLANKET YESCOMPRESSOR HEAT YES

OUTDOOR FAN — TYPE PROPELLERDIA. (IN.) - NO. USED 27.6 - 1TYPE DRIVE - NO. SPEEDS DIRECT - 2CFM @ 0.0 IN. W.G. 4 3975NO. MOTORS - HP. 1 - 1/3MOTOR SPEED R.P.M. 660VOLTS/PH/HZ 200/230/1/60F.L. AMPS 2.80OUTDOOR COIL — TYPE SPINE FIN™ROWS - F.P.I. 1 - 24FACE AREA (SQ. FT.) 24.88TUBE SIZE (IN.) 5/16REFRIGERANT CONTROL EXPANSION VALVEREFRIGERANT R-410A(O.D. UNIT) NP CHRG. 5 8/04-LB/OZFACTORY SUPPLIED YESLINE SIZE - IN. O.D. GAS 6 3/4LINE SIZE - IN. O.D. LIQ. 6 3/8FCCVRESTRICTOR ORIFICE SIZE N/ADIMENSIONS H X W X DOUTDOOR UNIT CRATED (IN.) 46.4 X 35.1 X 38.7UNCRATED SEE OUTLINE DWG.WEIGHTSHIPPING (LBS.) 300NET (LBS.) 253

4TWX6036B1000AGeneralData

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARYHEAT PUMP EQUIPMENT CERTIFICATION PROGRAM, WHICH ISBASED ON A.R.I. STANDARD 210/240.

2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6.3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.

ONLY USE HACR CIRCUIT BREAKERS OR FUSES.4 STANDARD AIR - DRY COIL - OUTDOOR5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT

NAMEPLATE AND SERVICE INSTRUCTION.6 MAX. LINEAR LENGTH: 80 FT. MAX. LIFT - SUCTION 25 FT; MAX LIFT -

LIQUID 25 FT. FOR GREATER LENGTH REFER TO REFRIGERANTPIPING SOFTWARE PUB. NO. 32-3312-01.

7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNITNAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TOCOMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUMFUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUITSELECTION CURRENT.

8 NO MEANS NO START COMPONENTSYES MEANS QUICK START KIT COMPONENTSPTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

SPLIT SYSTEM

Page 9: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

22-1754-05A 9

GeneralData 4TWX6048B1000A

OUTDOOR UNIT 12 4TWX6048B1000ASOUND RATING (DECIBELS) 2 78POWER CONNS. — V/PH/HZ 3 230/1/60MIN. BRCH. CIR. AMPACITY 29BR. CIR. MAX. (AMPS) 50PROT. RTG. } MIN. (AMPS) 50COMPRESSOR CLIMATUFF® - SCROLLNO. USED - NO. SPEEDS 1 - 2VOLTS/PH/HZ 230/1/60R.L. AMPS 7 - L.R. AMPS 21.2 - 96FACTORY INSTALLED

START COMPONENTS 8 NOINSULATION/SOUND BLANKET YESCOMPRESSOR HEAT YES

OUTDOOR FAN — TYPE PROPELLERDIA. (IN.) - NO. USED 27.6 - 1TYPE DRIVE - NO. SPEEDS DIRECT - 2CFM @ 0.0 IN. W.G. 4 4200NO. MOTORS - HP. 1 - 1/3MOTOR SPEED R.P.M. 660VOLTS/PH/HZ 200/230/1/60F.L. AMPS 2.80OUTDOOR COIL — TYPE SPINE FIN™ROWS - F.P.I. 1 - 24FACE AREA (SQ. FT.) 27.81TUBE SIZE (IN.) 5/16REFRIGERANT CONTROL EXPANSION VALVEREFRIGERANT R-410A(O.D. UNIT) NP CHRG. 5 9/01-LB/OZFACTORY SUPPLIED YESLINE SIZE - IN. O.D. GAS 6 7/8LINE SIZE - IN. O.D. LIQ. 6 3/8FCCVRESTRICTOR ORIFICE SIZE N/ADIMENSIONS H X W X DOUTDOOR UNIT CRATED (IN.) 53.4 X 35.1 X 38.7UNCRATED SEE OUTLINE DWG.WEIGHTSHIPPING (LBS.) 322NET (LBS.) 274

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARYHEAT PUMP EQUIPMENT CERTIFICATION PROGRAM, WHICH ISBASED ON A.R.I. STANDARD 210/240.

2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6.3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.

ONLY USE HACR CIRCUIT BREAKERS OR FUSES.4 STANDARD AIR - DRY COIL - OUTDOOR5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT

NAMEPLATE AND SERVICE INSTRUCTION.6 MAX. LINEAR LENGTH: 80 FT. MAX. LIFT - SUCTION 25 FT; MAX LIFT -

LIQUID 25 FT. FOR GREATER LENGTH REFER TO REFRIGERANTPIPING SOFTWARE PUB. NO. 32-3312-01.

7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNITNAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TOCOMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUMFUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUITSELECTION CURRENT.

8 NO MEANS NO START COMPONENTSYES MEANS QUICK START KIT COMPONENTSPTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

SPLIT SYSTEM

Page 10: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

10 22-1754-05A

GeneralData 4TWX6060B1000A

OUTDOOR UNIT 12 4TWX6060B1000ASOUND RATING (DECIBELS) 2 79POWER CONNS. — V/PH/HZ 3 230/1/60MIN. BRCH. CIR. AMPACITY 35BR. CIR. MAX. (AMPS) 60PROT. RTG. } MIN. (AMPS) 60COMPRESSOR CLIMATUFF® - SCROLLNO. USED - NO. SPEEDS 1 - 2VOLTS/PH/HZ 230/1/60R.L. AMPS 7 - L.R. AMPS 25.6 - 118FACTORY INSTALLED

START COMPONENTS 8 YESINSULATION/SOUND BLANKET YESCOMPRESSOR HEAT YES

OUTDOOR FAN — TYPE PROPELLERDIA. (IN.) - NO. USED 27.6 - 1TYPE DRIVE - NO. SPEEDS DIRECT - 2CFM @ 0.0 IN. W.G. 4 4400NO. MOTORS - HP. 1 - 1/3MOTOR SPEED R.P.M. 660VOLTS/PH/HZ 200/230/1/60F.L. AMPS 2.80OUTDOOR COIL — TYPE SPINE FIN™ROWS - F.P.I. 2 - 24FACE AREA (SQ. FT.) 26.32TUBE SIZE (IN.) 5/16REFRIGERANT CONTROL EXPANSION VALVEREFRIGERANT R-410A(O.D. UNIT) NP CHRG. 5 11/03-LB/OZFACTORY SUPPLIED YESLINE SIZE - IN. O.D. GAS 6 7/8LINE SIZE - IN. O.D. LIQ. 6 3/8FCCVRESTRICTOR ORIFICE SIZE N/ADIMENSIONS H X W X DOUTDOOR UNIT CRATED (IN.) 53.4 X 35.1 X 38.7UNCRATED SEE OUTLINE DWG.WEIGHTSHIPPING (LBS.) 360NET (LBS.) 312

1 CERTIFIED IN ACCORDANCE WITH THE AIR-SOURCE UNITARYHEAT PUMP EQUIPMENT CERTIFICATION PROGRAM, WHICH ISBASED ON A.R.I. STANDARD 210/240.

2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6.3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE.

ONLY USE HACR CIRCUIT BREAKERS OR FUSES.4 STANDARD AIR - DRY COIL - OUTDOOR5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT

NAMEPLATE AND SERVICE INSTRUCTION.6 MAX. LINEAR LENGTH: 80 FT. MAX. LIFT - SUCTION 25 FT; MAX LIFT -

LIQUID 25 FT. FOR GREATER LENGTH REFER TO REFRIGERANTPIPING SOFTWARE PUB. NO. 32-3312-01.

7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNITNAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TOCOMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUMFUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUITSELECTION CURRENT.

8 NO MEANS NO START COMPONENTSYES MEANS QUICK START KIT COMPONENTSPTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

SPLIT SYSTEM

Page 11: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

22-1754-05A 11

4TWX6024A 4TWX6036A

ElectricalData

Schematic Diagrams(SEE LEGEND)

Page 12: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

12 22-1754-05A

ElectricalData

4TWX6048A

Schematic Diagrams

4TWX6060A

Page 13: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

22-1754-05A 13

Dimensions

4TWX6 Outline DrawingNOTE: ALL DIMENSIONS ARE IN MM (INCHES)

From Dwg. 21D152635 Rev. 10

MODELS BASE A B C D E F G H J K

4TWX6024A 3 1118 (44) 829 (32-5/8) 756 (29-3/4) 5/8 5/16 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 692 (27-1/4)

4TWX6036A 4 1165 (45-7/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4)

4TWX6048A 4 1267 (49-7/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4)

4TWX6060A 4 1267 (49-7/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4)

LEGEND

SYMBOLS

Page 14: Split System Heat Pump Product & Performance Data System Heat Pump Product & Performance Data XL16i ... Selection Procedure 6 ... HEAT PUMP EQUIPMENT CERTIFICATION PROGRAM,

Literature Order Number

File Number

Supersedes

Stocking Location 04/09

Trane has a policy of continuous product and product data improvement and it reserves the right to changedesign and specifications without notice.

Tranewww.trane.com

MechanicalSpecification Options

GeneralThe 4TWX60 is fully charged from thefactory for up to 15 feet of piping. Thisunit is designed to operate at outdoorambient temperatures as high as 115°F.Cooling capacities are matched with awide selection of air handlers andfurnace coils that are A.R.I. certified. Theunit is certified to UL 1995. Exterior isdesigned for outdoor application.

CasingUnit casing is constructed of heavygauge, G90 galvanized steel and paintedwith a weather-resistant powder painton all louvered panels, prepaint on allother panels. Corrosion and weather-proof CMBP-G30 Duratuff™ base.

Refrigerant ControlsRefrigeration system controls includecondenser fan, compressor contactorand high pressure switch. High and lowpressure controls are inherent to thecompressor. A factory installed liquid linedrier is standard.

CompressorThe Climatuff® compressor featuresinternal over temperature and pressureprotection and total dipped hermeticmotor. Other features include: roto locksuction and discharge refrigerantconnections, centrifugal oil pump andlow vibration and noise.

Condenser CoilThe outdoor coil provides low airflowresistance and efficient heat transfer.The coil is protected on all four sides bylouvered panels.

Low Ambient CoolingAs manufactured, this unit has a coolingcapability to 55°F. The addition of anevaporator defrost control permitsoperation to 40° F. The addition of anevaporator defrost control with TXVpermits low ambient cooling to 30° F.

AccessoriesThermostats — Cooling only andheat/cooling (manual and automaticchangeover). Sub-base to match thermo-stat and locking thermostat cover.

Evaporator Defrost Control — See LowAmbient Cooling.