spessoril2010

20
Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215 E-mail [email protected] 1 SETTING SHIMS BOXES IDENTIFICATION NUMBERS CHARACTERISTICS FITTING POSITION SUMMARY REFERENCE Pg. 02 CR BOSCH INJECTORS: - CRIP 1.0 – 1.2 Pg. 04 - CRIP 2.2 Pg. 05 - CRIP 2.1 Pg. 06 - CRIN 1.0 Pg. 07 - CRIN 2.0 Pg. 08 - PIEZO Pg. 09 - VOLKSWAGEN 16V I° SERIE Pg. 10 - VOLKSWAGEN 16V II° SERIE Pg. 11 CR DELPHI INJECTORS Pg. 12 CR DENSO INJECTORS Pg. 14 CR SIEMENS – PIEZO INJECTORS Pg. 16 DX75470 KIT TO GRIND SETTING SHIMS Pg. 18 DX75391 DIGITAL MICROMETER GAUGE Pg. 20 (20.10.10)

Upload: oscaes-car

Post on 29-Aug-2014

178 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 1

SETTING SHIMS BOXES IDENTIFICATION NUMBERS

CHARACTERISTICS FITTING POSITION

SUMMARY ►REFERENCE Pg. 02 ►CR BOSCH INJECTORS: - CRIP 1.0 – 1.2 Pg. 04 - CRIP 2.2 Pg. 05 - CRIP 2.1 Pg. 06 - CRIN 1.0 Pg. 07 - CRIN 2.0 Pg. 08 - PIEZO Pg. 09 - VOLKSWAGEN 16V I° SERIE Pg. 10 - VOLKSWAGEN 16V II° SERIE Pg. 11 ►CR DELPHI INJECTORS Pg. 12 ►CR DENSO INJECTORS Pg. 14 ►CR SIEMENS – PIEZO INJECTORS Pg. 16 ►DX75470 KIT TO GRIND SETTING SHIMS Pg. 18 ►DX75391 DIGITAL MICROMETER GAUGE Pg. 20 (20.10.10)

Page 2: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 2

ATTENTION !

- This brochure should be considered a useful guide for the operator. We decline all responsibility for any mistake or modification occurred after the compilation of this brochure.

- At exhaustion of individual measures, replacement is available on request (10 pcs. Bag).

- Shims with different thickness, not included in the boxes can be available on request (10 pcs. Bag ).

Page 3: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 3

ATTENZIONE ! - Questo prontuario vuole rappresentare una guida utile per l’ utente. Decliniamo qualsiasi responsabilità per eventuali errori o modifiche successivamente intervenute alla compilazione del prontuario stesso.

- Singole misure di spessori in esaurimento sono disponibili su ordinazione (Bustine da 10 pz.).

- Singole misure di spessori non comprese nelle cassette possono essere disponibili su richiesta (Bustine da 10 pz.).

Page 4: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 4

CR BOSCH INJECTORS

N° 1 DX08050 24 Position Box

N° 2 DX08051 24 Position Box

N° 3 DX08056 12 Position Box

N° 4 DX08052 12 Position Box

N° 5 DX08051 24 Position Box

N° 6 DX08054 12 Position Box

BOSCH Common Rail Injector CRIP 1.0 - 1.2

Page 5: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 5

CR BOSCH INJECTORS

N° 1 DX08086 24 Position Box

N° 2 DX08056 12 Position Box

N° 3 DX08080 12 Position Box

N° 4 DX08052 12 Position Box

N° 5 DX08051 24 Position Box

N° 6 DX08054 12 Position Box

BOSCH Common Rail Injector CRIP 2.2

Page 6: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 6

CR BOSCH INJECTORS

N° 1 DX08053 12 Position Box

N° 2 DX08081 12 Position Box

N° 3 DX08056 12 Position Box

N° 4 DX08051 24 Position Box

N° 5 DX08054 12 Position Box

N° 6 DX08068 12 Position Box

BOSCH Common Rail Injector CRIP 2.1

Page 7: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 7

CR BOSCH INJECTORS

N° 1 DX08057 24 Position Box

N° 2 DX08084 12 Position Box

N° 3 DX08083 24 Position Box

N° 4 DX08051 24 Position Box

N° 5 DX08071 21 Position Box

CR BOSCH INJECTORS

BOSCH Common Rail Injector CRIN 1.0

Page 8: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 8

N° 1 DX08087 24 Position Box

N° 2 DX08067 24 Position Box

N° 3 DX08051 24 Position Box

N° 4 DX08054 12 Position Box

N° 5 DX08068 12 Position Box

CR BOSCH INJECTORS

BOSCH Common Rail Injector CRIN 2.0

Page 9: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 9

N° 1 DX08091 12 Position Box

N° 2 DX08090 12 Position Box

BOSCH PIEZO

Page 10: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 10

CR BOSCH INJECTORS

N° 1 DX08076 24 Position Box

BOSCH VOLKSWAGEN 16V I° SERIE

Page 11: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 11

CR BOSCH INJECTORS

N° 1 DX08077 24 Position Box

BOSCH VOLKSWAGEN 16V II° SERIE

Page 12: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 12

DELPHI INJECTORS

N° 1 DX08061 12 Position Box

Delphi common rail

Page 13: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 13

DELPHI INJECTORS

N° 1 DX08073

12 Position Box

N° 2 DX08074 12 Position Box

Volvo Injector FH HV Delphi Type

Page 14: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 14

CR DENSO INJECTORS

N° 1 DX08065 12 Position Box

N° 3 DX08069 12 Position Box

DENSO Common Rail X2 Type

Page 15: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 15

CR DENSO INJECTORS

N°1 DX08400 24 Position Box

N° 3 DX08069 12 Position Box

DENSO Common Rail G2 Type

Page 16: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 16

CR SIEMENS – PIEZO INJECTORS

N° 1 DX08064 12 Position Box

N° 1 DX08401

12 Position Box

N° 3 DX08062 12 Position Box

SIEMENS – PIEZO Common Rail Injector Type 5 WS 4000 0

Page 17: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 17

CR SIEMENS – PIEZO INJECTORS

N° 1 DX08088 24 Position Box

N° 2 DX08062 12 Position Box

SIEMENS – PIEZO Common Rail Injector Type 5 WS 4014 8 - 40149

Page 18: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 18

DX75470 KIT TO GRIND SETTING SHIMS ON CR

INJECTORS

EASY TO USE

Shim fitting on its Holder

Fitting of grinding disc support on DX75480

grinding machine.

Page 19: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 19

Top holder fitting

GRINDING DISCS

Kit includes: - Article DX75723 Thin grinding discs (Kit 10 pz.) - Article DX75724 Medium grinding discs (Kit 10 pz.) - Article DX75729 Thick grinding discs (Kit 10 pz.)

ATTENTION - To use of the DX75470 Kit is necessarily linked to the availability of the Ball seat reconditioning DX75480. - For the correct use of the DX75470 Kit is recommended synthetic liquid DX75374. - For the measurement of the thickness is recommended Digital micrometer gauge DX75391.

Page 20: SpessoriL2010

Nova Ditex S.r.l. – Loc. Mandella P.O. BOX 81 - 37019 Peschiera del Garda (VR) - Italy Phone n. +390456401191 Fax n. +390457552215

E-mail [email protected] 20

DX75391 DIGITAL MICROMETER GAUGE

CHARACTERISTIC

LCD Display Travel mm 0-25

Resolution mm 0.001 Isolation IP54

Precision DIN 863 DX75392

MICROMETER GAUGE HOLDER

COMPLET KIT (Recommended)