spectrometers - sensor+test · optical design and a 70mm optical bench to achieve a higher...

2
Innovative Measurement Technologies Common Specifications Wavelength Range (nm) 350-2500 Dimensions (mm) 196 x 86 x 53 Interface USB 2.0 Weight (g) 545 Power Requirements 10-30 VDC, 300-600mA @12VDC Model Specific Specifications: Front side illuminated CCD and TE Cooled InGaAs Linear Array SPM-001: M N NIR1700S NIR2500W Spectral Range (nm) 740-860 680-920 900-1700 1250-2500 Resolution (center/outer) (nm) 0.12 / 0.18 0.24 / 0.30 3.5 / 5 5 / 8 Standard Slit (um) 10 10 25 25 Fiber Input FC FC SMA SMA Detector Type CCD CCD InGaAs, single stage cooling InGaAs, double stage cooling Pixels 3648 3648 512 512 A/D Converter (bits) 12 12 16 16 Exposure Time Range 10usec to 65 sec 10usec to 65 sec 10usec to 10 sec 10usec to 10 sec Dimensions (mm) 196 x 86 x 53 196 x 86 x 53 244 x 90 x 53 244 x 90 x 53 Temperature Range ( C ) -10 to 55 -10 to 55 10 to 40 10 to 40 1.Slit sizes of 10, 25, 50 and 100um are available 2.SMA or FC fiber input available on all models SPM-001 High Resolution Spectrometer e SPM-001 is Photon Control’s high resolution benchtop spectrometer. It uses a proprietary optical design and a 150mm optical bench, to achieve up to 0.12nm resolution (SPM-001-M). It is available with either a front side illuminated Toshiba TCD1304 CCD for visible wavelength ranges, or, a TE cooled Hamamatsu InGaAs linear array for NIR sensitivity up to 2500nm. SPECTROMETERS Selection Guide Common Specifications Wavelength Range (nm) 190-1700 Dimensions (mm) 196 x 86 x 53 Interface USB 2.0 Weight (g) 545 Fiber Input SMA Power Requirements 10-30 VDC, 300mA @12VDC and/or USB Powered 1.Slit sizes of 10, 25, 50 and 100um are available 2.SMA or FC fiber input available on all models Model Specific Specifications: Front side illuminated CCD SPM-002: A B C D E AH BH CH DH EH Spectral Range (nm) 400-700 190-400 350-1000 200-850 200-1090 400-700 190-400 350-1000 200-850 200-1090 Resolution (center/outer) (nm)* 0.5/0.6 0.6/0.7 0.5/0.7 0.6/1.6 0.8/2 0.5/0.6 0.6/0.7 0.5/0.7 0.6/1.6 0.8/2 Standard Slit (um) 25 25 25 25 25 25 25 25 25 25 Detector Type CCD CCD CCD CCD CCD CCD CCD CCD CCD CCD Pixels 3648 3648 3648 3648 3648 3648 3648 3648 3648 3648 A/D Converter (bits) 12 12 12 12 12 16 16 16 16 16 Exposure Time Range 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec 10usec to 65 sec Temperature Range ( C ) -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55 SPM-002 Compact Spectrometer e SPM-002 is the most versatile spectrometer in the Photon Control product line. It uses a proprietary optical design and a 70mm optical bench to achieve a higher resolution than other spectrometers of the same size on the market. e SPM-002 is available with 4 different linear arrays, depending on the appli- cation. ese include a front side illuminated Toshiba CCD TCD1304DG for general purpose measure- ment applications, a Hamamatsu S9840 and S11071-1106 back-thinned CCD’s for high UV sensitivity and a Hamamatsu G9204-512D InGaAs linear array for NIR sensitivity.

Upload: trinhkhue

Post on 19-Jul-2018

231 views

Category:

Documents


2 download

TRANSCRIPT

Innovative Measurement Technologies

Common SpecificationsWavelength Range (nm) 350-2500 Dimensions (mm) 196 x 86 x 53Interface USB 2.0 Weight (g) 545Power Requirements 10-30 VDC, 300-600mA @12VDC

Model Specific Specifications: Front side illuminated CCD and TE Cooled InGaAs Linear Array

SPM-001: M N NIR1700S NIR2500WSpectral Range (nm) 740-860 680-920 900-1700 1250-2500Resolution (center/outer) (nm) 0.12 / 0.18 0.24 / 0.30 3.5 / 5 5 / 8Standard Slit (um) 10 10 25 25Fiber Input FC FC SMA SMADetector Type CCD CCD InGaAs, single stage cooling InGaAs, double stage coolingPixels 3648 3648 512 512A/D Converter (bits) 12 12 16 16Exposure Time Range 10usec to 65 sec 10usec to 65 sec 10usec to 10 sec 10usec to 10 secDimensions (mm) 196 x 86 x 53 196 x 86 x 53 244 x 90 x 53 244 x 90 x 53Temperature Range ( C ) -10 to 55 -10 to 55 10 to 40 10 to 401.Slit sizes of 10, 25, 50 and 100um are available 2.SMA or FC fiber input available on all models

SPM-001 High Resolution SpectrometerThe SPM-001 is Photon Control’s high resolution benchtop spectrometer. It uses a proprietary optical design and a 150mm optical bench, to achieve up to 0.12nm resolution (SPM-001-M). It is available with either a front side illuminated Toshiba TCD1304 CCD for visible wavelength ranges, or, a TE cooled Hamamatsu InGaAs linear array for NIR sensitivity up to 2500nm.

SPECTROMETERSSelection Guide

Common SpecificationsWavelength Range (nm) 190-1700 Dimensions (mm) 196 x 86 x 53Interface USB 2.0 Weight (g) 545Fiber Input SMA Power Requirements 10-30 VDC, 300mA @12VDC and/or USB Powered1.Slit sizes of 10, 25, 50 and 100um are available 2.SMA or FC fiber input available on all models

Model Specific Specifications: Front side illuminated CCDSPM-002: A B C D E AH BH CH DH EHSpectral Range (nm) 400-700 190-400 350-1000 200-850 200-1090 400-700 190-400 350-1000 200-850 200-1090Resolution (center/outer) (nm)* 0.5/0.6 0.6/0.7 0.5/0.7 0.6/1.6 0.8/2 0.5/0.6 0.6/0.7 0.5/0.7 0.6/1.6 0.8/2Standard Slit (um) 25 25 25 25 25 25 25 25 25 25Detector Type CCD CCD CCD CCD CCD CCD CCD CCD CCD CCDPixels 3648 3648 3648 3648 3648 3648 3648 3648 3648 3648A/D Converter (bits) 12 12 12 12 12 16 16 16 16 16

Exposure Time Range10usec to

65 sec10usec to

65 sec10usec to

65 sec10usec to

65 sec10usec to

65 sec10usec to

65 sec10usec to

65 sec10usec to

65 sec10usec to

65 sec10usec to

65 sec

Temperature Range ( C ) -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55 -10 to 55

SPM-002 Compact SpectrometerThe SPM-002 is the most versatile spectrometer in the Photon Control product line. It uses a proprietary optical design and a 70mm optical bench to achieve a higher resolution than other spectrometers of the same size on the market. The SPM-002 is available with 4 different linear arrays, depending on the appli-cation. These include a front side illuminated Toshiba CCD TCD1304DG for general purpose measure-ment applications, a Hamamatsu S9840 and S11071-1106 back-thinned CCD’s for high UV sensitivity and a Hamamatsu G9204-512D InGaAs linear array for NIR sensitivity.

SPL-2H: Tungsten Halogen Light Source

SPL-1DH: Deuterium Halogen Light Source

SPL-HGAR:Mercury Argon Light Source

WARRANTY: All Photon Control Spectrometer Products come with a 1-year warranty. Some limitations apply, please contact us for more details. © January 17, 2011 Photon Control Inc. Photon Control, Photon branding, Photon Control corporate logos, and FluoTemp are trademarks of Photon Control Inc.

Specifications subject to change without notice.

200-8363 Lougheed Highway, Burnaby, BC, Canada V5A 1X3

Tel: 604.422.8861 Fax: 604.422.8418

Email: [email protected] Web: www.photon-control.com

Model Specific Specifications: Back-thinned CCD and InGaAs Linear Array SPM-002: BT DT ET BT64 DT64 ET64 NIR1700Spectral Range (nm) 190-400 200-850 200-1090 190-400 200-850 200-1090 900-1700Resolution (center/outer) (nm)* 0.6/0.7 0.6/1.6 0.8/2 0.6/0.7 0.6/1.6 0.8/2 3.5/5Standard Slit (um) 25 25 25 25 25 25 25

Detector TypeBack-thinned

CCDBack-thinned

CCDBack-thinned

CCDBack-thinned

CCDBack-thinned

CCDBack-thinned

CCD InGaAs

Pixels 2048x14 2048x14 2048x14 2048x64 2048x64 2048x64 512A/D Converter (bits) 16 16 16 16 16 16 16Exposure Time Range 2.2msec to 10 sec 2.2msec to 10 sec 2.2msec to 10 sec 3msec to 10 sec 3msec to 10 sec 3msec to 10 sec 10usec to 10 secTemperature Range ( C ) -10 to 40 -10 to 40 -10 to 40 -10 to 40 -10 to 40 -10 to 40 -10 to 40* measured with 10 um slit for SPM-002-X/XH/XT/XT64

Light Sources

SPL-2H TYPICAL SPECTRAL CURVE:

SPL-1DH TYPICAL SPECTRAL CURVE:

SPL-HGAR TYPICAL SPECTRAL CURVE:

ModelSpectral Range

(nm)Lifetime (MTBF, hrs)

Fiber Connector

Operating Temperature Range ( C )

Power SupplyDimensions

(mm)Weight (g)

SPL-2H Tungsten-Halogen 350-2000 10000 SMA -10 to 60 12 VDC, 650mA 116x40x43 165SPL-1DH Deuterium-Halogen 200-1100 D2 – 1000; Halogen - 2000 SMA 5 to 35 12 VDC, 650mA 118x81x47 385SPL-HGAR Mercury-Argon 250-1000 3000 SMA 25 12 VDC, 650mA 145x62x23 135

Photos Reflectance Probes, Cuvette Holder, Breakout Board, etcItem Description Item DescriptionSPA-COU Cuvette Holder, 4 way SPA-COL-UVI-FC Light Collector, UV/Vis/IR, FCSPA-RP-SMA-200-U Reflectance probe, 6 around 1, 200um core UV/Vis fibers, SMA

connectorsSPA-WREF-1 White Reference StandardSPA-PL-COUV-1 Plastic Cuvettes, 1cm path, 10 pack

SPA-RP-SMA-200-V Reflectance probe, 6 around 1, 200um core Vis/NIR fibers, SMA connectors

SPA-RP-HOLD-1 Reflectance probe holderSPA-BREAKOUT-1 Breakout circuit board for spectrometer interface connector

SPA-COL-UVI-SMA Light Collector, UV/Vis/IR, SMACWA-SMA-62-V-2 Fiber Optic Patch Cord - SMA 905 connector - 62.5 micrometer

core - VIS/NIR - 2mCWA-FC-62-V-2 Fiber Optic Patch Cord - FC connector - 62.5 micrometer

core - VIS/NIR - 2mCWA-SMA-100-V-2 Fiber Optic Patch Cord - SMA 905 connector - 100 micrometer

core - VIS/NIR - 2mCWA-FC-100-V-2 Fiber Optic Patch Cord - FC connector - 100 micrometer

core - VIS/NIR - 2mCWA-SMA-200-V-2 Fiber Optic Patch Cord - SMA 905 connector - 200 micrometer

core - VIS/NIR - 2mCWA-FC-200-V-2 Fiber Optic Patch Cord - FC connector - 200 micrometer

core - VIS/NIR - 2mCWA-SMA-400-V-2 Fiber Optic Patch Cord - SMA 905 connector - 400 micrometer

core - VIS/NIR - 2mCWA-FC-400-V-2 Fiber Optic Patch Cord - FC connector - 400 micrometer

core - VIS/NIR - 2mCWA-SMA-600-V-2 Fiber Optic Patch Cord - SMA 905 connector - 600 micrometer

core - VIS/NIR - 2mCWA-FC-600-V-2 Fiber Optic Patch Cord - FC connector - 600 micrometer

core - VIS/NIR - 2mCWA-SMA-100-U-2 Fiber Optic Patch Cord - SMA 905 connector - 100 micrometer

core - UV/VIS - 2mCWA-FC-100-U-2 Fiber Optic Patch Cord - FC connector - 100 micrometer

core - UV/VIS - 2mCWA-SMA-200-U-2 Fiber Optic Patch Cord - SMA 905 connector - 200 micrometer

core - UV/VIS - 2mCWA-FC-200-U-2 Fiber Optic Patch Cord - FC connector - 200 micrometer

core - UV/VIS - 2mCWA-SMA-400-U-2 Fiber Optic Patch Cord - SMA 905 connector - 400 micrometer

core - UV/VIS - 2mCWA-FC-400-U-2 Fiber Optic Patch Cord - FC connector - 400 micrometer

core - UV/VIS - 2mCWA-SMA-600-U-2 Fiber Optic Patch Cord - SMA 905 connector - 600 micrometer

core - UV/VIS - 2mCWA-FC-600-U-2 Fiber Optic Patch Cord - FC connector - 600 micrometer

core - UV/VIS - 2mCWA-FC-SMF-V-2 Fiber Optic Patch Cord - FC connector - SMF 28 fiber -

VIS/NIR - 2m

Spectroscopy Patch cords and Sampling AccessoriesPhoton Control offers a wide range of spectroscopy accessories. These include cuvette holders, reflectance probes, light collectors, breakout boards and patchcords. We can also offer custom sampling assemblies for OEM applications.