specification guide for chrysler powertrain applications - … · 2011-11-23 · 4 chrysler...
TRANSCRIPT
Specification Guide for Chrysler Powertrain Applications
Cordsets, Connectors, Fieldbus, and Ethernet/IP Products
Revison 8.5
Release Date: January 2012
2Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Table of Contents
Revision Log 3
Worldwide Contacts 4
Connectivity Solutions 5-63
Mini 7/8” | 1” | 1 1/8” 5-38Multiport Distribution BoxesHome Run CablesCordsets (Single and Double-Ended)ReceptaclesField Attachable Connectors
Micro M12 39-54Multiport Distribution BoxesHome Run CablesCordsets (Single and Double Ended)ReceptaclesField Attachable ConnectorsSplitters
Pico M8 55-63Multiport Distribution BoxesCordsets (Single and Double-EndedReceptaclesField Attachable ConnectorsSplitters
Fieldbus Solutions 64-149
Profibus-DP 64-77Input/Output ModulesBus CordsetsField Attachable ConnectorsTerminating Resistors
AS-Interface 78-115Input/Output ModulesFlat CablePassive Distribution BoxesCable JunctionsAccessories
LioN-Link I/O Modules 116-149LioN-Link BusHead Profibus SlavesLioN-Link Digital I/O ModulesLioN-Link BusHead ProfiNet-I/O Device-Slave (ProfiNet LAN)LioN-Link Power Distributor W/ M12 Sockets
Industrial Ethernet 150-165
Switches - UnmannagedPanel Adaptors (M12 - RJ45)Cordsets (CAT5e Shielded and Unshielded)Field Attachable Connectors Accessories
Part Number Index 166-168
3www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Revision Log
Revision # Date Type Change Description
Revision 8.5 11/22/2011 Updates Updated: Worldwide Contact page, Table of Contents, and Part Number Index to reflect added products.
Revision 8.5 11/22/2011 Product Additions Added: RK 100M-752/...M, RSRK 1001M-752/...M, RSRK 100M-752/...M, RK 120M-776/...M, RSRK 1201M-776/...M, RSRK120M-776/...M, RK 190M-769/...M, RSRK 1901M-769/...M, and RSRK 190M-769/...M.
Revision 8.5 10/14/2011 Product Additions Added: TC-ER Rated Single- and Doubled-Ended Cordsets RK 40-839/...M, RK 50-877/...M, RKW 40-839/...M, RKW 50-877/...M,RSRK 40-839/...M, RSRK 50-877/...M, RSRK 401-839/...M. RSRK 501-877/...M, RSRKW 40-839/...M, RSRKW 50-877/...M, RSRKW 401-839/...M, RSRKW 501-877/..M, RK 90M-751/...M, and RSRK 901M-751/...M.
Revision 8 07/01/2011 Product Deletions Deleted PowerCINCH. Pages 148-156.
Revision 8 07/01/2011 Product Additions Added LioN-M EtherNet/IP-Device: 0980 ESL 711 EtherNet/IP Device with 16 digital I/O channels, channels can be used universally as inputs or outputs, M12 socket, rotary address switches for addressing, M12 LAN-Ports, D-coded, 7/8“ power supply.
Revision 8 07/01/2011 Product Additions Added LioN-M EtherNet/IP-Device: 0980 ESL 710 EtherNet/IP Device with 16 digital inputs, M12 socket, rotary address switches for addressing, M12 LAN-Ports, D-coded, 7/8“ power supply.
4Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Worldwide Contacts
North America
Mr. Cliff Reid3465 Hilton Estates Dr.Brighton, MI 48114USATel. 810 355 8904E-mail [email protected]
Mr. John T. JonesH.H. Barnum Company7915 Lochlin DriveBrighton, MI 48116USATel. 734.260.2349E-Mail: [email protected]: www.hhbarnum.com
EMEA (Europe Middle East and Africa)
Mr. Mehmet AkcitBelden Deutschland GmbH Im Gewerbepark 258579 Schalksmühle, GERMANY Tel.: +49 2355 5044 109E-mail: [email protected]: www.beldensolutions.com
APAC (Asia Pacific)
Mr. AikHong TanBelden Automation (Asia Pacific) Pte Ltd27 International Business Park#05-01 iQuest@IBPSingapore, SINGAPORE 609924Tel. +65 6854 9864Fax: +65 6567 9845E-mail: [email protected]
Italy
Mr. Luciano Rosa MarinVia Parco Abbaziale 14Giaveno, Torino, ITALY 10094Tel.: +39 011 9363 752E-Mail: [email protected]
5www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Mini Distribution Box
ZLU 4-50
Face View 7/8” Face View 1 1/8” Wiring Diagram
Description
MINI, Distribution Box, 4-Port, Solenoid
Wired, 5-Pole, Home Run Connector 10-Pole,
600V, Box Color Yellow/Black, IP 68 / NEMA
6P Rated.
Pin Assignments and Wiring Diagram
Technical Data
Material
Body Polyester (glass-filled), yellow
TPE, black
I/O Port Shell Zinc alloy, black e-coated
Control Port Shell Aluminum, black anodized
Contacts Brass, gold over nickel plated
Insert Polyurethane, yellow
Electrical
Current Rating 8A per port
12A max. per box
Voltage Rating 600 V
Mechanical
Temperature -25°C to + 90°C
Protection IP 68, NEMA 6P
Home Run Cable RK 100M-699/...F
Cable Lengths 12F and 20F
1 = white2 = red3 = green4 = orange5 = black
1 = orange2 = blue3 = white/black4 = red/black5 = green/black6 = orange/black7 = red8 = green9 = balck10 = white
Part Number
ZLU 4-50
6Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Mini Single-Ended Cordsets
RK 40-839 | RK 50-877
Face View 7/8”
Description
MINI, Single-Ended Cordset, Straight, Female
(internal threads), 4- and 5-Pole, 16 AWG, Yel-
low TPE (TC-ER) Cable, U.S. Color Code, IP 68
and NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, e-coated or
anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket Yellow, TPE
Gauge 16 AWG stranded copper
UL Approval TC-ER
Outside diameter 839: .342”
877: .371”
1 = white2 = red3 = green4 = orange5 = black
1 = black2 = white3 = red4 = green
Part Number
RK 40-839/1M RK 50-877/1M
RK 40-839/2M RK 50-877/2M
RK 40-839/3M RK 50-877/3M
RK 40-839/5M RK 50-877/5M
RK 40-839/10M RK 50-877/10M
RK 40-839/20M RK 50-877/20M
7www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Mini Single-Ended Cordsets
RKW 40-839 | RKW 50-877
Face View 7/8”
Description
MINI, Single-Ended Cordset, Right Angle,
Female (internal threads), 4- and 5-Pole, 16
AWG, Yellow TPE (TC-ER) Cable, U.S. Color
Code, IP 68 and NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, e-coated or
anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket Yellow, TPE
Gauge 16 AWG stranded copper
UL Approval TC-ER
Outside diameter 839: .342”
877: .371”
Part Number
RKW 40-839/1M RKW 50-877/1M
RKW 40-839/2M RKW 50-877/2M
RKW 40-839/3M RKW 50-877/3M
RKW 40-839/5M RKW 50-877/5M
RKW 40-839/10M RKW 50-877/10M
RKW 40-839/20M RKW 50-877/20M
1 = white2 = red3 = green4 = orange5 = black
1 = black2 = white3 = red4 = green
8Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Mini Single-Ended Cordsets
RK 50-777
Face View 7/8”
Description
MINI, Single-Ended Cordset, Straight, Female,
5 Pole, 16 AWG, SEOOW, Yellow TPE Cable, U.S.
Color Code, IP 68 and NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, e-coated or
anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -50°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket Yellow, TPE
Gauge 16 AWG
UL SEOOW
Outside diameter .495” (12.6 mm)
1 = white2 = red3 = green4 = orange5 = black
Part Number
RK 50-777/6F
RK 50-777/12F
RK 50-777/15F
RK 50-777/20F
RK 50-777/25F
RK 50-777/30F
9www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Mini Single-Ended Cordsets
RKW 50-777
Face View 7/8”
Description
MINI, Single-Ended Cordset, Right Angle,
Female, 5 Pole, 16 AWG, SEOOW, Yellow TPE
Cable, U.S. Color Code, IP 68 and NEMA 6P
Pin Assignments
Rated.
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, e-coated or
anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -50°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket Yellow, TPE
Gauge 16 AWG
UL SEOOW
Outside diameter .495” (12.6 mm)
1 = white2 = red3 = green4 = orange5 = black
Part Number
RKW 50-777/6F
RKW 50-777/12F
RKW 50-777/15F
RKW 50-777/20F
RKW 50-777/25F
RKW 50-777/30F
10Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Mini Single-Ended Cordsets
RK 80M-650
Face View 7/8”
Description
MINI, Single-Ended Cordset, Straight, Female,
8 Pole, 18 AWG, AWM 20233, Yellow, PUR
Cable, U.S. Color Code, IP 68 and NEMA 6P
Pin Assignments
1”-1
6 U
NF-
2B
Rated.
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, e-coated or
anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 5 A
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket Yellow, PUR
Gauge 18 AWG
UL AWM 20233
Outside diameter .315”
1 = orange2 = blue3 = white/black4 = black5 = white6 = red7 = green8 = red/black
Part Number
RK 80M-650/6F
RK 80M-650/12F
RK 80M-650/15F
RK 80M-650/20F
RK 80M-650/30F
11www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Mini Single-Ended Cordsets
RK 90M-751
Face View 1 1/8”
Description
MINI, Single-Ended Cordset, Straight, Female
(internal threads), 9-Pole, 18 AWG, Yellow TPE
(PLTC) Cable, U.S. Color Code, IP 67 and NEMA
6P Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, black anodized
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 7 A
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 67, NEMA 6P
Cable
Jacket Yellow, TPE
Gauge 18 AWG stranded copper
UL Approval PLTC
Outside diameter .381”
1 = orange2 = blue3 = red / black tr.4 = green / black tr.5 = white6 = red7 = green8 = white / black tr.9 = black
Part Number
RK 90M-751/1M
RK 90M-751/2M
RK 90M-751/3M
RK 90M-751/5M
RK 90M-751/10M
RK 90M-751/20M
12Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Mini Single-Ended Cordsets
RK 100M-652
Face View 7/8”
Description
MINI, Single-Ended Cordset, Straight,
Female,10 Pole, 18 AWG, AWM 20233, Yellow,
PUR Cable, U.S. Color Code, IP 68 and NEMA
6P Rated.
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 7 A
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P rated
Cable
Jacket Yellow, PUR
Gauge 18 AWG
UL AWM 20233
Outside diameter .331”
Pin Assignments
1 = orange2 = blue3 = white/black4 = red/black5 = green/black6 = orange/black7 = red8 = green9 = black10 = white
Part Number
RK 100M-652/6F
RK 100M-652/12F
RK 100M-652/15F
RK 100M-652/20F
RK 100M-652/30F
13www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Mini Single-Ended Cordsets
RK 100M-752
Face View 7/8”
Description
MINI, Single-Ended Cordset, Straight,
Female,10 Pole, 18 AWG, PLTC, Yellow. TPE
Cable, U.S. Color Code, IP 67 and NEMA 6P
Rated.
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 7 A
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 67, NEMA 6P rated
Cable
Jacket PUR, Yellow
Gauge 18 AWG
UL PLTC
Outside diameter .380”
Pin Assignments
1 = orange2 = blue3 = white / black tracer4 = red / black tracer5 = green / black tracer6 = orange /black tracer7 = red8 = green9 = black10 = white
Part Number
RK 100M-752/1M
RK 100M-752/2M
RK 100M-752/3M
RK 100M-752/5M
RK 100M-752/10M
RK 100M-752/20M
14Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Mini Single-Ended Cordsets
RK 120M-676 | RK 190M-669
Face View 1 1/8”
Description
MINI, Single-Ended Cordset, 12- and 19-Pole,
18 AWG, PUR Yellow Cable, NUMERIC Color
Code, Oil and Abrasion Resistant. IP 68 / NEMA
6P rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 676: 5 A
699: 12 A (pos. 5-7), 3 A
(pos. 1-4, 6, 13-19),
ground (pos. 12)
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket Yellow, PUR
Gauge 18 AWG
UL AWM 20233
Stranding 18 AWG
Outside diameter 676: .390”
699: .489”
1 = black w/ NUMBER “1”2 = black w/ NUMBER “2”3 = black w/ NUMBER “3”4 = black w/ NUMBER “4”5 = black w/ NUMBER “5”6 = black w/ NUMBER “6”7 = black w/ NUMBER “7”8 = black w/ NUMBER “8”9 = green w/ yellow tracer10 = black w/ NUMBER “10”11 = black w/ NUMBER “11”12 = black w/ NUMBER “12”
1 = black w/ NUMBER “1”2 = black w/ NUMBER “2”3 = black w/ NUMBER “3”4 = black w/ NUMBER “4”5 = black w/ NUMBER “5”6 = black w/ NUMBER “6”7 = black w/ NUMBER “7”8 = black w/ NUMBER “8”9 = black w/ NUMBER “9”10 = black w/ NUMBER “10”
Part Number
RK 120M-676/6F RK 190M-699/5M
RK 120M-676/12F RK 190M-699/10M
RK 120M-676/15F RK 190M-699/15M
RK 120M-676/20F
RK 120M-676/25F
RK 120M-676/30F
11 = black w/ NUMBER “11”12 = green w/ yellow tracer13 = black w/ NUMBER “13”14 = black w/ NUMBER “14”15 = black w/ NUMBER “15”16 = black w/ NUMBER “16” 17 = black w/ NUMBER “17”18 = black w/ NUMBER “18”19 = black w/ NUMBER “19”
15www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Mini Single-Ended Cordsets
RK 120M-776 | RK 190M-769
Face View 1 1/8”
Description
MINI, Single-Ended Cordset, 12- and 19-Pole,
18 AWG, PLTC, TPE Yellow Cable, NUMERIC
Color Code. IP 67 / NEMA 6P rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 776: 5 A
769: 3 A (pos. 1-4, 6, 8-11, 13-19)
12 A (pos. 5, 7),
ground (pos. 12)
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 67, NEMA 6P
Cable
Jacket TPE, Yellow
Gauge 18 AWG, stranded
UL PLTC
Outside diameter 776: .438”
769: .530”
1 = black w/ NUMBER “1”2 = black w/ NUMBER “2”3 = black w/ NUMBER “3”4 = black w/ NUMBER “4”5 = black w/ NUMBER “5”6 = black w/ NUMBER “6”7 = black w/ NUMBER “7”8 = black w/ NUMBER “8”9 = green w/ yellow tracer10 = black w/ NUMBER “10”11 = black w/ NUMBER “11”12 = black w/ NUMBER “12”
1 = black w/ NUMBER “1”2 = black w/ NUMBER “2”3 = black w/ NUMBER “3”4 = black w/ NUMBER “4”5 = black w/ NUMBER “5”6 = black w/ NUMBER “6”7 = black w/ NUMBER “7”8 = black w/ NUMBER “8”9 = black w/ NUMBER “9”10 = black w/ NUMBER “10”
Part Number
RK 120M-776/1M RK 190M-769/1M
RK 120M-776/2M RK 190M-769/2M
RK 120M-776/3M RK 190M-769/3M
RK 120M-776/5M RK 190M-769/5M
RK 120M-776/10M RK 190M-769/10M
RK 120M-776/20M RK 190M-769/20M
11 = black w/ NUMBER “11”12 = green w/ yellow tracer13 = black w/ NUMBER “13”14 = black w/ NUMBER “14”15 = black w/ NUMBER “15”16 = black w/ NUMBER “16” 17 = black w/ NUMBER “17”18 = black w/ NUMBER “18”19 = black w/ NUMBER “19”
16Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
RSRK 40-839 | RSRK 50-877
Face View 7/8”
Description
MINI, Double-Ended Cordset, Straight, Male
(external threads) to Female (internal threads),
4- and 5-Pole, 16 AWG, Yellow TPE (TC-ER)
Cable, U.S. Color Code, IP 68 and NEMA 6P
Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, e-coated or
anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket Yellow, TPE
Gauge 16 AWG stranded copper
UL Approval TC-ER
Outside diameter 839: .342”
877: .371”
1 = white2 = red3 = green4 = orange5 = black
Part Number
RSRK 40-839/1M RSRK 50-877/1M
RSRK 40-839/2M RSRK 50-877/2M
RSRK 40-839/3M RSRK 50-877/3M
RSRK 40-839/5M RSRK 50-877/5M
RSRK 40-839/10M RSRK 50-877/10M
RSRK 40-839/20M RSRK 50-877/20M
1 = black2 = white3 = red4 = green
Mini Double-Ended Cordsets
17www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
RSRK 401-839 | RSRK 501-877
Face View 7/8”
Description
MINI, Double-Ended Cordset, Straight, Male
(internal threads) to Female (internal threads),
4- and 5-Pole, 16 AWG, Yellow TPE (TC-ER)
Cable, U.S. Color Code, IP 68 and NEMA 6P
Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, e-coated or
anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket Yellow, TPE
Gauge 16 AWG stranded copper
UL Approval TC-ER
Outside diameter 839: .342”
877: .371”
1 = white2 = red3 = green4 = orange5 = black
Part Number
RSRK 401-839/1M RSRK 501-877/1M
RSRK 401-839/2M RSRK 501-877/2M
RSRK 401-839/3M RSRK 501-877/3M
RSRK 401-839/5M RSRK 501-877/5M
RSRK 401-839/10M RSRK 501-877/10M
RSRK 401-839/20M RSRK 501-877/20M
1 = black2 = white3 = red4 = green
Mini Double-Ended Cordsets
18Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
1 = white2 = red3 = green4 = orange5 = black
1 = black2 = white3 = red4 = green
RSRKW 40-839 | RSRKW 50-877
Face View 7/8”
Description
MINI, Double-Ended Cordset, Straight Male
(external threads) to Right Angle Female
(internal threads), 4- and 5-Pole, 16 AWG,
Yellow TPE (TC-ER) Cable, U.S. Color Code, IP
68 and NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, e-coated or
anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket Yellow, TPE
Gauge 16 AWG stranded copper
UL Approval TC-ER
Outside diameter 839: .342”
877: .371”
Part Number
RSRKW 40-839/1M RSRKW 50-877/1M
RSRKW 40-839/2M RSRKW 50-877/2M
RSRKW 40-839/3M RSRKW 50-877/3M
RSRKW 40-839/5M RSRKW 50-877/5M
RSRKW 40-839/10M RSRKW 50-877/10M
RSRKW 40-839/20M RSRKW 50-877/20M
Mini Double-Ended Cordsets
19www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
1 = white2 = red3 = green4 = orange5 = black
1 = black2 = white3 = red4 = green
RSRKW 401-839 | RSRKW 501-877
Face View 7/8”
Description
MINI, Double-Ended Cordset, Straight Male
(internal threads) to Right Angle Female
(internal threads), 4- and 5-Pole, 16 AWG,
Yellow TPE (TC-ER) Cable, U.S. Color Code, IP
68 and NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, e-coated or
anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket Yellow, TPE
Gauge 16 AWG stranded copper
UL Approval TC-ER
Outside diameter 839: .342”
877: .371”
Part Number
RSRKW 401-839/1M RSRKW 501-877/1M
RSRKW 401-839/2M RSRKW 501-877/2M
RSRKW 401-839/3M RSRKW 501-877/3M
RSRKW 401-839/5M RSRKW 501-877/5M
RSRKW 401-839/10M RSRKW 501-877/10M
RSRKW 401-839/20M RSRKW 501-877/20M
RSRKW 501-877/20M
Mini Double-Ended Cordsets
20Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
1 = black2 = blue3 = brown4 = white
Mini Double-Ended Cordsets
RSRK 401-637
Face View 7/8”
Description
MINI, Double-Ended Cordset, 4 Pole, Straight
Male (external threads) to Straight Female
(internal threads), 18 AWG, TPE Yellow Cable,
IEC Color Code, Oil and Weather Resistant,
C-Track and Weld Slag Rated. IP 67 / NEMA 6P.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum (e-coated, black)
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 5.6 A
Voltage rating 300 V
Mechanical
Temperature -50°C to + 90°C
Protection IP 67, NEMA 6P
Cable
Jacket Yellow, PUR
Gauge 18 AWG
UL PLTC
Outside diameter .280”
Part Number
RSRK 401-637/6F
RSRK 401-637/12F
RSRK 401-637/15F
RSRK 401-637/20F
RSRK 401-637/30F
21www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
1 = white2 = red3 = green4 = orange5 = black
Mini Double-Ended Cordsets
RSRK 501-777
Face View 1 1/8”
Description
Mini, Double Ended Cordset, Male (internal
threads) to Female (internal threads) Straight,
5-Pole, U.S. Color Code, 16 AWG, TPE cable,
SEOOW, Yellow Jacket, IP67 / NEMA 6P rated .
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -50°C to + 90°C
Protection IP 67, NEMA 6P
Cable
Jacket Yellow, PVC
Gauge 16 AWG
UL SEOOW
Outside diameter .495”
Part Number
RSRK 501M-777/6F
RSRK 501M-777/12F
RSRK 501M-777/15F
RSRK 501M-777/20F
RSRK 501M-777/30F
22Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
1 = orange2 = blue3 = white/black4 = black5 = white6 = red7 = green8 = red/black
Mini Double-Ended Cordsets
RSRK 801M-650
Face View 1”
Description
MINI, Double-Ended Cordset, 8 Pole, Straight
Male to Straight Female, 18 AWG, PUR Yellow
Cable, NEC Color Code, Oil and Abrasion
Resistant, IP 67 / NEMA 6P.
Pin Assignments
1" -
16
UN
F-2
B1"
- 1
6 U
NF
-2B
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 5 A
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 67, NEMA 6P
Cable
Jacket Yellow, PVC
Gauge 18 AWG
UL AWM 20233
Stranding 18 AWG
Outside diameter .315”
Part Number
RSRK 801M-650/6F
RSRK 801M-650/12F
RSRK 801M-650/15F
RSRK 801M-650/20F
RSRK 801M-650/25F
RSRK 801M-650/30F
23www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
RSRK 90M-751
Face View 1 1/8”
Description
MINI, Double-Ended Cordset, Straight, Male
(external threads) to Female (internal threads),
9-Pole, 18 AWG, Yellow TPE (PLTC) Cable, U.S.
Color Code, IP 67 and NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, black anodized
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 7 A
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 67, NEMA 6P
Cable
Jacket Yellow, TPE
Gauge 18 AWG stranded copper
UL Approval PLTC
Outside diameter .381”
1 = orange2 = blue3 = red / black tr.4 = green / black tr.5 = white6 = red7 = green8 = white / black tr.9 = black
Part Number
RSRK 90M-751/1M
RSRK 90M-751/2M
RSRK 90M-751/3M
RSRK 90M-751/5M
RSRK 90M-751/10M
RSRK 90M-751/20M
Mini Double-Ended Cordsets
24Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
RSRK 901M-751
Face View 1 1/8”
Description
MINI, Double-Ended Cordset, Straight, Male
(internal threads) to Female (internal threads),
9-Pole, 18 AWG, Yellow TPE (PLTC) Cable, U.S.
Color Code, IP 67 and NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, black anodized
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 7 A
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 67, NEMA 6P
Cable
Jacket Yellow, TPE
Gauge 18 AWG stranded copper
UL Approval PLTC
Outside diameter .381”
1 = orange2 = blue3 = red / black tr.4 = green / black tr.5 = white6 = red7 = green8 = white / black tr.9 = black
Part Number
RSRK 901M-751/1M
RSRK 901M-751/2M
RSRK 901M-751/3M
RSRK 901M-751/5M
RSRK 901M-751/10M
RSRK 901M-751/20M
Mini Double-Ended Cordsets
25www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
RSRK 1001M-752
Face View 1 1/8”
Description
MINI, Double-Ended Cordset, Straight, Male
(internal threads) to Female (internal threads),
10-Pole, 18 AWG, Yellow TPE (PLTC) Cable, U.S.
Color Code, IP 67 and NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, black anodized
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 7 A
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 67, NEMA 6P
Cable
Jacket TPE, Yellow
Gauge 18 AWG, stranded
UL Approval PLTC
Outside diameter .380”
1 = orange2 = blue3 = white / black tracer4 = red / black tracer5 = green / black tracer6 = orange / black tracer7 = red8 = green9 = black10 = white
Part Number
RSRK 1001M-752/1M
RSRK 1001M-752/2M
RSRK 1001M-752/3M
RSRK 1001M-752/5M
RSRK 1001M-752/10M
RSRK 1001M-752/20M
Mini Double-Ended Cordsets
26Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
RSRK 100M-752
Face View 1 1/8”
Description
MINI, Double-Ended Cordset, Straight, Male
(external threads) to Female (internal threads),
10-Pole, 18 AWG, Yellow TPE (PLTC) Cable, U.S.
Color Code, IP 67 and NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 7 A
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 67, NEMA 6P rated
Cable
Jacket PUR, Yellow
Gauge 18 AWG
UL PLTC
Outside diameter .380”
1 = orange2 = blue3 = white / black tracer4 = red / black tracer5 = green / black tracer6 = orange /black tracer7 = red8 = green9 = black10 = white
Part Number
RSRK 100M-752/1M
RSRK 100M-752/2M
RSRK 100M-752/3M
RSRK 100M-752/5M
RSRK 100M-752/10M
RSRK 100M-752/20M
Mini Double-Ended Cordsets
27www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
1 = orange2 = blue3 = white/black4 = red/black5 = green/black6 = orange/black7 = red8 = green9 = black10= white
RSRK 1001M-699
Face View 1 1/8”
Description
Mini, Double Ended Home Run Cable, Male
(internal threads) to Female (internal threads)
Straight, 10-Pole, 16 AWG, PVC cable, for ZLU
Distribution Boxes.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 7 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket Yellow, PVC
Gauge 16 AWG
UL STOOW
Outside diameter .660”
Part Number
RSRK 1001M-699/6F
RSRK 1001M-699/15F
Mini Double-Ended Cordsets
28Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Mini Double-Ended Cordsets
RSRK 1201M-676 | RSRK 1901M-669
Face View 1 1/8”
Description
MINI, Double-Ended Cordset, 12- and 19-Pole,
Straight Male (internal threads) to Straight
Female (internal threads), 18 AWG, PUR Yellow
Cable, NUMERIC Color Code. IP 67 / NEMA 6P
rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 676: 5 A
699: 12 A (pos. 5-7), 3 A
(pos. 1-4, 6, 13-19),
ground (pos. 12)
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 67, NEMA 6P
Cable
Jacket Yellow, PUR
Gauge 18 AWG
UL AWM 20233
Stranding 18 AWG
Outside diameter 676: .390”
699: .489”
Part Number
RSRK 1201M-676/6F RSRK 1901M-669/2M
RSRK 1201M-676/12F RSRK 1901M-669/5M
RSRK 1201M-676/15F RSRK 1901M-669/10M
RSRK 1201M-676/20F
RSRK 1201M-676/25F
RSRK 1201M-676/30F
1 = black w/ NUMBER “1”2 = black w/ NUMBER “2”3 = black w/ NUMBER “3”4 = black w/ NUMBER “4”5 = black w/ NUMBER “5”6 = black w/ NUMBER “6”7 = black w/ NUMBER “7”8 = black w/ NUMBER “8”9 = green w/ yellow tracer10 = black w/ NUMBER “10”11 = black w/ NUMBER “11”12 = black w/ NUMBER “12”
1 = black w/ NUMBER “1”2 = black w/ NUMBER “2”3 = black w/ NUMBER “3”4 = black w/ NUMBER “4”5 = black w/ NUMBER “5”6 = black w/ NUMBER “6”7 = black w/ NUMBER “7”8 = black w/ NUMBER “8”9 = black w/ NUMBER “9”10 = black w/ NUMBER “10”
11 = black w/ NUMBER “11”12 = green w/ yellow tracer13 = black w/ NUMBER “13”14 = black w/ NUMBER “14”15 = black w/ NUMBER “15”16 = black w/ NUMBER “16” 17 = black w/ NUMBER “17”18 = black w/ NUMBER “18”19 = black w/ NUMBER “19”
RSRK 1201M-676
RSRK 1901M-669
29www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Part Number
RSRK 1201M-776/1M RSRK 1901M-769/1M
RSRK 1201M-776/2M RSRK 1901M-769/2M
RSRK 1201M-776/3M RSRK 1901M-769/3M
RSRK 1201M-776/5M RSRK 1901M-769/5M
RSRK 1201M-776/10M RSRK 1901M-769/10M
RSRK 1201M-776/20M RSRK 1901M-769/20M
Mini Double-Ended Cordsets
RSRK 1201M-776 | RSRK 1901M-769
Face View 1 1/8”
Description
MINI, Double-Ended Cordset, 12- and 19-Pole,
Straight Male (internal threads) to Straight
Female (internal threads), 18 AWG, TPE (PLTC)
Yellow Cable, NUMERIC Color Code. IP 67 /
NEMA 6P rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 776: 5 A
769: 3 A (pos. 1-4, 6, 8-11, 13-19)
12 A (pos. 5, 7),
ground (pos. 12)
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 67, NEMA 6P
Cable
Jacket TPE, Yellow
Gauge 18 AWG, stranded
UL PLTC
Stranding 18 AWG
Outside diameter 776: .438”
769: .530”
1 = black w/ NUMBER “1”2 = black w/ NUMBER “2”3 = black w/ NUMBER “3”4 = black w/ NUMBER “4”5 = black w/ NUMBER “5”6 = black w/ NUMBER “6”7 = black w/ NUMBER “7”8 = black w/ NUMBER “8”9 = green w/ yellow tracer10 = black w/ NUMBER “10”11 = black w/ NUMBER “11”12 = black w/ NUMBER “12”
1 = black w/ NUMBER “1”2 = black w/ NUMBER “2”3 = black w/ NUMBER “3”4 = black w/ NUMBER “4”5 = black w/ NUMBER “5”6 = black w/ NUMBER “6”7 = black w/ NUMBER “7”8 = black w/ NUMBER “8”9 = black w/ NUMBER “9”10 = black w/ NUMBER “10”
11 = black w/ NUMBER “11”12 = green w/ yellow tracer13 = black w/ NUMBER “13”14 = black w/ NUMBER “14”15 = black w/ NUMBER “15”16 = black w/ NUMBER “16” 17 = black w/ NUMBER “17”18 = black w/ NUMBER “18”19 = black w/ NUMBER “19”
RSRK 1201M-776
RSRK 1901M-769
30Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Mini Double-Ended Cordsets
RSRK 120M-776 | RSRK 190M-769
Face View 1 1/8”
Description
MINI, Double-Ended Cordset, 12- and 19-Pole,
Straight Male (external threads) to Straight
Female (internal threads), 18 AWG, TPE Yellow
Cable, NUMERIC Color Code. IP 67 / NEMA 6P.
rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Aluminum, anodized black
Contacts Brass, gold plated
Insert PUR, yellow
Electrical
Current rating 776: 5 A
769: 3 A (pos. 1-4, 6, 8-11, 13-19)
12 A (pos. 5, 7),
ground (pos. 12)
Voltage rating 300 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 67, NEMA 6P
Cable
Jacket TPE, Yellow
Gauge 18 AWG, stranded
UL PLTC
Stranding 18 AWG
Outside diameter 776: .438”
769: .530”
RSRK 120M-776
RSRK 190M-769
1 = black w/ NUMBER “1”2 = black w/ NUMBER “2”3 = black w/ NUMBER “3”4 = black w/ NUMBER “4”5 = black w/ NUMBER “5”6 = black w/ NUMBER “6”7 = black w/ NUMBER “7”8 = black w/ NUMBER “8”9 = green w/ yellow tracer10 = black w/ NUMBER “10”11 = black w/ NUMBER “11”12 = black w/ NUMBER “12”
1 = black w/ NUMBER “1”2 = black w/ NUMBER “2”3 = black w/ NUMBER “3”4 = black w/ NUMBER “4”5 = black w/ NUMBER “5”6 = black w/ NUMBER “6”7 = black w/ NUMBER “7”8 = black w/ NUMBER “8”9 = black w/ NUMBER “9”10 = black w/ NUMBER “10”
11 = black w/ NUMBER “11”12 = green w/ yellow tracer13 = black w/ NUMBER “13”14 = black w/ NUMBER “14”15 = black w/ NUMBER “15”16 = black w/ NUMBER “16” 17 = black w/ NUMBER “17”18 = black w/ NUMBER “18”19 = black w/ NUMBER “19”
Part Number
RSRK 120M-776/1M RSRK 190M-769/1M
RSRK 120M-776/2M RSRK 190M-769/2M
RSRK 120M-776/3M RSRK 190M-769/3M
RSRK 120M-776/5M RSRK 190M-769/5M
RSRK 120M-776/10M RSRK 190M-769/10M
RSRK 120M-776/20M RSRK 190M-769/20M
31www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
1 = black2 = white3 = red4 = green
Mini Receptacles
RKF 401-639
Face View 7/8”
Description
MINI, Receptacle, 4 Pole, Female Straight 1/2-
Inch NPT, 16 AWG, PVC insulated leads, epoxy
potted, NEC Color Code, IP 68 / NEMA 6P.
Pin Assignments
Technical Data
Material
Insert PUR, yellow
Contacts Brass, gold over silver plated
O-ring Viton™
Receptacle shell Zinc die cast (e-coated, black)
Locknut Steel, zinc plated
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Part Number
RKF 401-639/1F
32Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
1 = black2 = white3 = red4 = green
Mini Receptacles
RSF 40-639
Face View 7/8”
Description
MINI, Receptacle, 4 Pole, Male Straight 1/2-
Inch NPT, 16 AWG, PVC insulated leads, epoxy
potted, NEC Color Code, IP 68 / NEMA 6P.
Pin Assignments
Technical Data
Material
Insert PUR, yellow
Contacts Brass, gold over silver plated
O-ring Viton™
Receptacle shell Zinc die cast (e-coated, black)
Locknut Steel, zinc plated
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Part Number
RSF 40-639/1F
33www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
1 = white2 = red3 = green4 = orange5 = black
Mini Receptacles
RSF 50-677
Face View 7/8”
Description
MINI, Receptacle, 5 Pole, Front Mount, Male
Straight 1/2-Inch NPT, U.S. Color Code, IP 68 /
NEMA 6P rated.
Pin Assignments
Technical Data
Material
Insert PUR, yellow
Contacts Brass, gold plated
O-ring Viton™
Receptacle shell Zinc die cast (e-coated, black)
Locknut Steel, zinc plated
Electrical
Current rating 8 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Part Number
RSF 50-677/1F
34Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
1 = orange2 = blue3 = white/black4 = black5 = white6 = red7 = green8 = red/black
Mini Receptacles
RKF 801-698
Face View 1”
Description
MINI, Receptacle, 8 Pole, Female Straight 1/2-
Inch NPT, 16 AWG, PVC insulated leads, epoxy
potted, NEC Color Code, IP 68 / NEMA 6P.
Pin Assignments
Technical Data
Material
Insert PUR, yellow
Contacts Brass, gold over nickel plated
O-ring Viton™
Receptacle shell Aluminum with clear anodize
Locknut Steel, zinc plated
Electrical
Current rating 7 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Part Number
RKF 801-698/1F
35www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
1 = orange2 = blue3 = white/black4 = black5 = white6 = red7 = green8 = red/black
Mini Receptacles
RSF 80M-698
Face View 1”
Description
MINI, Receptacle, 8 Pole, Male Straight 1/2-
Inch NPT, 16 AWG, PVC insulated leads, epoxy
potted, NEC Color Code, IP 68 / NEMA 6P.
Pin Assignments
Technical Data
Material
Insert PUR, yellow
Contacts Brass, gold over nickel plated
O-ring Viton™
Receptacle shell Aluminum with clear anodize
Locknut Steel, zinc plated
Electrical
Current rating 7 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Part Number
RSF 80M-698/1F
36Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
1 = orange2 = blue3 = white/black4 = red/black5 = green/black6 = orange/black7 = red8 = green9 = black10 = white
Mini Receptacles
RKF 1001M-699
Face View 1 1/8”
Description
Mini, Receptacle, Female, 10-Pole, 16 AWG,
1/2”-14 NPT mounting, NEC Color Code.
Pin Assignments
Technical Data
Material
Insert PUR, yellow
Contacts Brass, gold plated
O-ring Viton™
Receptacle shell Aluminum with clear anodize
Locknut Steel, zinc plated
Electrical
Current rating 7 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Part Number
RKF 1001M-699/1F
37www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
1 = orange2 = blue3 = white/black4 = red/black5 = green/black6 = orange/black
Mini Receptacles
RSF 120M-676
Face View 1 1/8”
Description
Mini, Receptacle, Male, 10-Pole, 1/2” NPT
mounting, U.S. Color Code.
Pin Assignments
Technical Data
Material
Insert PUR, yellow
Contacts Brass, gold plated
Receptacle shell Aluminum with clear anodize
Locknut Steel, zinc plated
O-ring Viton™
Electrical
Current rating 7 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Part Number
RSF 120M-676
7 = blue/black8 = blue/white9 = green10 = red11 = white12 = black
38Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
7 = blue/black8 = black/white9 = green10 = red11 = white12 = black
1 = orange2 = blue3 = white/black4 = red/black5 = green/black6 = orange/black
Mini Receptacles
RKF 1201M-624
Face View 1 1/8”
Description
MINI, Receptacle, 12 Pole, Female Straight 1/2-
Inch NPT, 16 AWG, PVC insulated leads, epoxy
potted, NEC Color Code, IP 68 / NEMA 6P.
Pin Assignments
Technical Data
Material
Insert PUR, yellow
Contacts Brass, gold over nickel plated
O-ring Viton™
Receptacle shell Aluminum with clear anodize
Locknut Steel, zinc plated
Electrical
Current rating 5 A
Voltage rating 600 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Part Number
RKF 1201M-624/1F
39www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Micro M12 Distribution Boxes
ASBSV 4/LED 5 | ASBSV 8/LED 5
Face View M12 / M23 Wiring Diagrams
Description
Micro (M12) Distribution Box, 4- and 8- Port,
5-Pole, two signals per port, with built-in LED
(PNP), M23 connection for the control cable,
IP 67 and NEMA 6P rated.
Pin Assignments
Technical Data
Mechanical
Housing TPU, self extinguishing
Contacts Brass, pre-nickeled and 0.8
microns gold-plated
Receptacle shell Brass, nickel plated
Insert PA GF, self-extinguishing
O-ring FKM
Electrical
Contact resistance ≤5mΩ
Voltage rating 10-30 V DC
Current rating 4 A per port
10 A max. total
Environmental
Temperature -15°C to + 80°C
Protection IP 67, NEMA 6P rated
Mating Home Control Cables
RKU 19-242/...M ro RKWU 19-242/...M
Part Number
ASBSV 4/LED 5
ASBSV 8/LED 5
1 = 19 (C1)2 = 1 (7) 2 (4) 3 (8) 4 (14)3 = 6 (C3)
1 = 19 (C1)2 = 1 (7) 2 (4) 3 (8) 4 (14) 5 (9) 6 (13) 7 (10) 8 (18)
4 = 1 (15) 2 (5) 3 (16) 4 (3)5 = 12 (PE)
3 = 6 (C3)4 = 1 (15) 2 (5) 3 (16) 4 (3) 5 (17) 6 (2) 7 (11) 8 (1)
5 = 12 (PE)
greenyellow green
yellow
40Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
M23 Single-Ended Control Cables
RKU 19-242 | RKWU 19-242
Face View M23
Description
M23 Control Cable, Straight or Right Angle,
Female, 19-Pole with PUR halogen-free,
black cable.
Technical Data
Material
Molded body TPU, self-extinguishing
Coupling nut Brass, nickel plated
Contacts Brass, pre-nickeled and
0.8 microns gold-plated
Insert PBT
Electrical
Current rating 8 A pin Ø 1 mm,
10 A pin Ø 1.5 mm
Voltage rating 120 V
Mechanical
Temperature -25°C to + 100°C
Protection IP 67, NEMA 6P rated
Cable
Jacket: PUR halogen-free, black
Gauge: 3 x 1.00 mm2
16 x 0.50 mm2
Outside diameter .457” (11.6 mm)
Pin Assignments
Part Number
RKU 19-242/5M
RKU 19-242/10M
RKU 19-242/15M
RKU 19-242/20M
RKWU 19-242/5M
RKWU 19-242/10M
RKWU 19-242/15M
RKWU 19-242/20M
1 = violet2 = red3 = grey4 = red/blue5 = green6 = blue7 = grey/pink8 = white/green9 = white/yellow10= white/grey
11= black12= yellow/green13= yellow/brown14= brown/green15= white16= yellow17= pink18= grey/brown19= brown
RKU
RKWU
41www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Micro M12 Distribution Boxes
ASB 4/LED 5/4-328/RS120M
Face View M12 Face View Mini 1 1/8” Wiring Diagram
Description
Micro M12 4 Port Actuator/Sensor Distribution
Box with LED, PUR (TPU) Halogen Free Hi-Flex
Black Cable with MINI 12-Pole -
Quick Disconnect Connector, IP 68 and NEMA
6P Rated.
Pin Assignments
Technical Data
Mechanical
Housing PUR, yellow
Contacts Brass, gold over nickel plated
Receptacle shell Brass, nickel plated
Insert Nylon
Electrical
Contact resistance ≤5mΩ
Current rating 4 A per port
12 A max. Per box
Environmental
Temperature -15°C to + 90°C
Protection IP 68, NEMA 6P
Cable Specifications
Voltage 300 V
Cable jacket PUR (TPU) halogen-free, black
Flex Hi-flex bare
Stranding 4 x 34mm2 and 3 x 75mm2
copper stranding
Outside diameter 6.8mm / .268”
Homerun cable RK 120M-676/...F
Part Number
ASB 4/LED 5/4-328/RS120M
1 = 12 (+)3 = 10 (-)4 = 1 (7) 2 (6) 3 (5) 4 (4)5 = 9 (gnd)
42Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
1 = 12 (+)3 = 10 (-)4 = 1 (7) 2 (6) 3 (5) 4 (4) 5 (3) 6 (2) 7 (1) 8 (8)5 = 9 (gnd)
Micro M12 Distribution Boxes
ASB 8/LED 5/4-331/RS120
Face View M12 Face View Mini 1 1/8” Wiring Diagram
Description
Micro M12 8 Port Actuator/Sensor Distribution
Box with LED, PUR (TPU) Halogen Free Hi-
Flex Black Cable with MINI 12-Pole Quick
Disconnect Connector, IP 68 and NEMA 6P
Rated.
Pin Assignments
Technical Data
Mechanical
Housing PUR, yellow
Contacts Brass, gold over nickel plated
Receptacle shell Brass, nickel plated
Insert Nylon
Electrical
Contact resistance ≤5mΩ
Current rating 4 A per port
12 A max. Per box
Environmental
Temperature -15°C to + 90°C
Protection IP 68, NEMA 6P
Cable Specifications
Voltage 300 V
Cable jacket PUR (TPU) halogen-free, black
Flex Hi-flex bare
Stranding 8 x 34mm2 and 3 x 75mm2
copper stranding
Outside diameter 8.0mm
Homerun cable RK 120M-676/...F
Part Number
ASB 8/LED 5/4-331/RS120
43www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Micro M12 Single-Ended Cordsets
RKT 4-602 | RKT 4-637 | RKT 4-643
Face View M12
Description
Micro M12 Single-Ended Cordset, 4-Pole,
Straight Female, 18AWG and 22AWG, 250V,
EURO DC Color Code, Yellow PUR or TPE
Jacket, IP 68 and NEMA 6P Rated.
Technical Data
Material
Molded body PUR, yellow
Coupling nut Brass, nickel plated
Contacts Brass, gold over nickel plated
Insert PUR, black
Electrical
Current rating 4 A
Voltage rating 250 V
Mechanical
Temperature 602: -40°C to + 90°C
637: -25°C to + 105°C
Protection IP 68, NEMA 6P
Cable 18AWG
Jacket: 602: PUR, yellow
637: TPE, yellow
22AWG
643: TPE, yellow
Outside diameter 602: .230” (5.8 mm)
637: .280” (7.1 mm)
643: .246” (6.2 mm)
Pin Assignments
Part Number
RKT 4-602/2M
RKT 4-602/5M
RKT 4-602/10M
RKT 4-637/2M
RKT 4-637/5M
RKT 4-637/10M
RKT 4-643/2M
RKT 4-643/5M
RKT 4-643/10M
1 = brown2 = white3 = blue4 = black RKT 4-637 & 643 (only)
44Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Micro M12 Single-Ended Cordsets
RST 4-602
Face View M12
Description
Micro M12 Single-Ended Cordset, 4-Pole,
Straight Male, 18 AWG, 250V, EURO DC Color
Code, Yellow PUR Jacket, IP 68 and NEMA 6P
Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Brass, nickel plated
Contacts Brass, gold over nickel plated
Insert PUR, black
Electrical
Current rating 4 A
Voltage rating 250 V
Mechanical
Temperature -40°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket: PUR, yellow
Gauge: 18 AWG
Outside diameter .230” (5.8 mm)
Part Number
RST 4-602/1M
1 = brown2 = white3 = blue4 = black
45www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Micro M12 Single-Ended Cordsets
RKWT 4-602 | RKWT 4-637 | RKWT 4-643
Face View M12
Description
Micro M12 Single-Ended Cordset, 4-Pole,
Right Angle Female, 18AWG and 22AWG,
250V, EURO DC Color Code, Yellow PUR or TPE
Jacket, IP 68 and NEMA 6P Rated.
Technical Data
Material
Molded body PUR, yellow
Coupling nut Brass, nickel plated
Contacts Brass, gold over nickel plated
Insert PUR, black
Electrical
Current rating 4 A
Voltage rating 250 V
Mechanical
Temperature 602: -40°C to + 90°C
637: -25°C to + 105°C
Protection IP 68, NEMA 6P
Cable 18AWG
Jacket: 602: PUR, yellow
637: TPE, yellow
22AWG
643: TPE, yellow
Outside diameter 602: .230” (5.8 mm)
637: .280” (7.1 mm)
643: .246” (6.2 mm)
Pin Assignments
Part Number
RKWT 4-602/2M
RKWT 4-602/5M
RKWT 4-602/10M
RKWT 4-637/2M
RKWT 4-637/5M
RKWT 4-637/10M
RKWT 4-643/2M
RKWT 4-643/5M
RKWT 4-643/10M
1 = brown2 = white3 = blue4 = black RST 4-RKT 4-637 & 643 (only)
46Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Micro M12 Double-Ended Cordsets
RST 4-RKT 4-602 | RST 4-RKT 4-637 | RST 4-RKT 4-643
Face View M12
Description
Micro M12 Double-Ended Cordset, 4-Pole,
Straight Male to Straight Female, 18 AWG and
22 AWG, 250V, EURO DC Color Code, Yellow
PUR or TPE
Jacket, IP 68 and NEMA 6P Rated.
Technical Data
Material
Molded body PUR, yellow
Coupling nut Brass, nickel plated
Contacts Brass, gold over nickel plated
Insert PUR, black
Electrical
Current rating 4 A
Voltage rating 250 V
Mechanical
Temperature 602: -40°C to + 90°C
637: -25°C to + 105°C
Protection IP 68, NEMA 6P
Cable 18AWG
Jacket: 602: PUR, yellow
637: TPE, yellow
22AWG
643: TPE, yellow
Outside diameter 602: .230” (5.8 mm)
637: .280” (7.1 mm)
643: .246” (6.2 mm)
Pin Assignments
Part Number
RST 4-RKT 4-602/0.3M
RST 4-RKT 4-602/0.6M
RST 4-RKT 4-602/1M
RST 4-RKT 4-602/2M
RST 4-RKT 4-602/3M
RST 4-RKT 4-602/5M
RST 4-RKT 4-637/0.3M
RST 4-RKT 4-637/0.6M
RST 4-RKT 4-637/1M
RST 4-RKT 4-637/2M
RST 4-RKT 4-637/3M
RST 4-RKT 4-637/5M
RST 4-RKT 4-643/0.3M
RST 4-RKT 4-643/0.6M
RST 4-RKT 4-643/1M
RST 4-RKT 4-643/2M
RST 4-RKT 4-643/3M
RST 4-RKT 4-643/5M
1 = brown2 = white3 = blue4 = black RST 4-RKT 4-637 & 643 (only)
47www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Micro M12 Double-Ended Cordsets
RST 4-RKWT 4-602 | RST 4-RKWT 4-637 | RST 4-RKWT 4-643
Face View M12
Description
Micro M12 Single-Ended Cordset, 4-Pole,
Straight Female to Right Angle Male,
18AWG and 22 AWG, 250V, EURO DC Color
Code, Yellow PUR orTPE Jacket, IP 68 and
NEMA 6P Rated.
Technical Data
Material
Molded body PUR, yellow
Coupling nut Brass, nickel plated
Contacts Brass, gold over nickel plated
Insert PUR, black
Electrical
Current rating 4 A
Voltage rating 250 V
Mechanical
Temperature 602: -40°C to + 90°C
637: -25°C to + 105°C
Protection IP 68, NEMA 6P
Cable 18AWG
Jacket: 602: PUR, yellow
637: TPE, yellow
22AWG
643: TPE, yellow
Outside diameter 602: .230” (5.8 mm)
637: .280” (7.1 mm)
643: .246” (6.2 mm)
Pin Assignments
Part Number
RST 4-RKWT 4-602/0.3M
RST 4-RKWT 4-602/0.6M
RST 4-RKWT 4-602/1M
RST 4-RKWT 4-602/2M
RST 4-RKWT 4-602/3M
RST 4-RKWT 4-602/5M
RST 4-RKWT 4-637/0.3M
RST 4-RKWT 4-637/0.6M
RST 4-RKWT 4-637/1M
RST 4-RKWT 4-637/2M
RST 4-RKWT 4-637/3M
RST 4-RKWT 4-637/5M
RST 4-RKWT 4-643/0.3M
RST 4-RKWT 4-643/0.6M
RST 4-RKWT 4-643/1M
RST 4-RKWT 4-643/2M
RST 4-RKWT 4-643/3M
RST 4-RKWT 4-643/5M
1 = brown2 = white3 = blue4 = black RST 4-RKWT 4-637 & 643 (only)
48Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Micro M12 Splitter
ASB2-RKT 4/3-645
Face View M12 Wiring Diagram
Description
Micro M12 Splitter, 18 AWG, Yellow, PUR, 2
Way with Two Female Plugs.
Pin Assignments
Technical Data
Material
Molded body PUR, yellow
Coupling nut Brass, nickel plated
Contacts Brass, gold over nickel plated
Insert PUR, yellow (male), black (female)
Electrical
Current rating 4 A
Voltage rating 250 V
Mechanical
Temperature -15°C to + 90°C
Protection IP 68, NEMA 6P
Cable
Jacket: PUR, yellow
Gauge: 18 AWG
Outside diameter .220” (5.6 mm)
Part Number
ASB2-RKT 4-3-645/0.3M
ASB2-RKT 4-3-645/0.6M
ASB2-RKT 4-3-645/1M
ASB2-RKT 4-3-645/1.5M
ASB2-RKT 4-3-645/2M
ASB2-RKT 4-3-645/5M
49www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Micro M12 Splitter
ASBS2 M12 S2326
Face View M12 Wiring Diagram
Description
Micro M12 Splitter, Black Housing with Two
Female Plugs, Brass, Nickel Plated Coupling
Nuts. IP 67 / NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body PUR, black
Coupling nut Brass, nickel plated
Contacts Brass, gold over nickel plated
Insert PUR, black (female), yellow
(male)
Electrical
Current rating 4 A
Voltage rating 250 V
Mechanical
Temperature -15°C to + 90°C
Protection IP 67, NEMA 6P
Part Number
ASBS2 M12 S2326
A B
50Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Micro M12 Receptacles
RKF 4-1/2-14 | RSF 4-1/2-14
Face View M12
Description
Micro M12 Receptacles
Pin Assignments
Technical Data
Material
Housing Aluminum, blue anodized
Mounting 1/2” 14-NPT
Contacts Brass, gold over nickel plated
Insert PUR, black (female), Nylon,
black (male)
Electrical
Current rating 4 A
Voltage rating 250 V
Conductor 22 AWG
Mechanical
Temperature -25°C to + 90°C
Protection IP 68, NEMA 6P
Part Number
RKF 4-1/2-14/0.5M
RSF 4-1/2-14/0.5M
1 = brown2 = white3 = blue4 = black
51www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Micro M12 Field Attachable Connectors
RKC 4/7 | RKCW 4/7
Face View M12
Description
Micro M12 Field Attachable, 4-Pole, Female
Straight and Right Angle, 250V, Screw
Termination for Wire Size up to 18 AWG, IP 67
and NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body Nylon, black
Coupling nut Brass, nickel plated
Contacts Brass, tin plated
Insert Nylon, black
Electrical
Current rating 4 A
Voltage rating 250 V
Mechanical
Temperature -25°C to + 90°C
Protection IP 67, NEMA 6P
Part Number
RKC 4/7
RKCW 4/7
52Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Micro M12 Field Attachable Connectors
RSC 4/7 | RSCW 4/7
Face View M12
Description
Micro M12 Field Attachable, 4-Pole, Male
Straight and Right Angle, 250V, Screw
Termination for Wire Size up to 18 AWG, IP 67
and NEMA 6P Rated.
Pin Assignments
Technical Data
Material
Molded body Nylon, black
Coupling nut Brass, nickel plated
Contacts Brass, tin plated
Insert Nylon, black
Electrical
Current rating 4 A
Voltage rating 250 V
Mechanical
Temperature -25°C to + 90°C
Protection IP 67, NEMA 6P
Part Number
RSC 4/7
RSCW 4/7
53www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Micro M12 Terminal Block Receptacles
RKF 5 TB
Face View M12 Color Code Panel Nut / Cut-Out
Description
Micro M12 Receptacle, 5 pole, 250V, Female to
Terminal Block.
Pin Assignments / Panel Nut
Technical Data
Material
Micro M12 Connector
Shell Brass, nickel plated
Panel nut Brass, nickel plated
Contacts Brass, gold over nickel plated
Insert Nylon, black
Sealing ring Viton™
Terminal Block
Header body Polyamide 66, green
Pins Brass, tin plated
Overmold Polymide, black
Electrical
Current rating 4 A
Voltage rating 250 V
Mechanical
Temperature -25°C to + 90°C
Protection IP 67, NEMA 6P
Recommended Mating Terminal Block
MC 100-508-06 180° wire exit
MC 200-508-06 90° wire exit (included)
Part Number
RKF 5 TB
Side View
Front View
Rear View
M12 Terminal Block1 12 23 34 45 5gnd 6
54Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Micro M12 Terminal Block Receptacles
RSF 5 TB
Face View M12 Color Code Panel Nut / Cut-Out
Description
Micro M12 Receptacle, 5 pole, 250V, Male to
Terminal Block.
Pin Assignments / Panel Nut
Technical Data
Material
Micro M12 Connector
Shell Brass, nickel plated
Panel nut Brass, nickel plated
Contacts Brass, gold over nickel plated
Insert Nylon, black
Sealing ring Viton™
Terminal Block
Header body Polyamide 66, green
Pins Brass, tin plated
Overmold Polymide, black
Electrical
Current rating 4 A
Voltage rating 250 V
Mechanical
Temperature -25°C to + 90°C
Protection IP 67, NEMA 6P
Recommended Mating Terminal Block
MC 100-508-06 180° wire exit
MC 200-508-06 90° wire exit (included)
Part Number
RSF 5 TB
Side View
Front View
Rear View
M12 Terminal Block1 12 23 34 45 5gnd 6
55www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Pico M8 Distribution Boxes
ASBM 4/LED 3-343
Face View M8 Color Code Wiring Diagram
Description
Pico M8 Distribution Box, 4-Port, 3-Pole, LED
(PNP) Indicators, Home Run Cable, Halogen-
Free PUR, Black, 0.25mm2, 10-30 VDC, Box
Color - Black, Euro DC Color Code, IP 67 and
NEMA 6P Rated.
Pin Assignments / Panel Nut
Technical Data
Material
Housing PBT, black
Insert PA, self-extinguishing, black
Contacts Brass, gold over nickel plated
Receptacle housing Brass, nickel plated
O-ring FKM
Electrical
Contact resistance ≤5mΩ
Current rating 1.5A per port,
1.5A max per box
Voltage rating 10-30 V DC
Mechanical
Temperature -25°C to + 70°C
Protection IP 67, NEMA 6P
Cable Specifications
Cable jacket PUR, halogen-free, black
Overal diameter 5.1mm
Conductor 6 x 0.25mm2
Part Number
ASBM 4/LED 3-343/5M
ASBM 4/LED 3-343/10M
1 = brown (+)2 = blue (-)3 = white (1) green (2) yellow (3) grey (4)
56Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Pico M8 Distribution Boxes
ASBM 8/LED 3-345
Face View M8 Color Code Wiring Diagram
Description
Pico M8 Distribution Box, 8-Port, 3-Pole, LED
(PNP) Indicators, Home Run Cable, Halogen-
Free PUR, Black, 0.25mm2, 10-30 VDC, Box
Color - Black, Euro DC Color Code, IP 67 and
NEMA 6P Rated.
Pin Assignments / Wiring Diagram
Technical Data
Material
Housing PBT, black
Insert PA, self-extinguishing, black
Contacts Brass, gold over nickel plated
Receptacle housing Brass, nickel plated
O-ring FKM
Electrical
Contact resistance ≤5mΩ
Current rating 1.5A per port,
1.5A max per box
Voltage rating 10-30 V DC
Mechanical
Temperature -25°C to + 70°C
Protection IP 67, NEMA 6P
Cable Specifications
Cable jacket PUR, halogen-free, black
Overal diameter 5.1mm
Conductor 6 x 0.25mm2
1 = brown (+)2 = blue (-)3 = white (1) green (2) yellow (3) grey (4) pink (5) red (6) black (7) violet (8)
Part Number
ASBM 8/LED 3-345/5M
ASBM 8/LED 3-345/10M
57www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Pico M8 Single-Ended Cordsets
RKMV 3-224
Face View M8 Color Code
Description
Pico M8 actuator/sensor single-ended, straight
female cordset with selflocking threaded joint
and molded cable, IP 67 / NEMA 6P rated.
Pin Assignments
Technical Data
Material
Molded body TPU
Insert PA / TPU
Contacts CuZn, pre-nickeled and
0.8 microns gold-plated
Receptacle shell CuZn, nickel plated
O-ring FKM
Electrical
Contact resistance ≤5mΩ
Current rating 4 A
Voltage rating 63 V
Test voltage 1.5 kV eff. / 60 s
Insulation resistance > 109 Ω
Mechanical
Temperature -25°C to + 80°C
Protection IP 67, NEMA 6P
Cable Specifications
Cable jacket PUR, halogen-free, black
Gauge 22 AWG
Outside diameter .185” (4.3 mm)
1 = brown3 = blue4 = black
Part Number
RKMV 3-224/2M
RKMV 3-224/5M
RKMV 3-224/10M
58Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Pico M8 Single-Ended Cordsets
RKMWV 3-224
Face View M8 Color Code
Description
Pico M8 actuator/sensor single-ended, right-
angle female cordset with selflocking threaded
joint and molded cable, IP 67 / NEMA 6P rated.
Pin Assignments
Technical Data
Material
Molded body TPU
Insert PA / TPU
Contacts CuZn, pre-nickeled and
0.8 microns gold-plated
Receptacle shell CuZn, nickel plated
O-ring FKM
Electrical
Contact resistance ≤5mΩ
Current rating 4 A
Voltage rating 63 V
Test voltage 1.5 kV eff. / 60 s
Insulation resistance > 109 Ω
Mechanical
Temperature -25°C to + 80°C
Protection IP 67, NEMA 6P
Cable Specifications
Cable jacket PUR, halogen-free, black
Gauge 22 AWG
Outside diameter .185” (4.3 mm)
1 = brown3 = blue4 = black
Part Number
RKMWV 3-224/2M
RKMWV 3-224/5M
RKMWV 3-224/10M
59www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Pico M8 Double-Ended Cordsets
RSMV 3-RKMV 3-224
Face View M8 Color Code
Description
Pico M8 actuator/sensor double-ended,
straight male to straight female cordset with
selflocking threaded joint and molded cable,
IP 67 / NEMA 6P rated.
Pin Assignments
Technical Data
Material
Molded body TPU
Insert PA / TPU
Contacts CuZn, pre-nickeled and
0.8 microns gold-plated
Receptacle shell CuZn, nickel plated
O-ring FKM
Electrical
Contact resistance ≤5mΩ
Current rating 4 A
Voltage rating 63 V
Test voltage 1.5 kV eff. / 60 s
Insulation resistance > 109 Ω
Mechanical
Temperature -25°C to + 80°C
Protection IP 67, NEMA 6P
Cable Specifications
Cable jacket PUR, halogen-free, black
Gauge 22 AWG
Outside diameter .185” (4.3 mm)
1 = brown3 = blue4 = black
Part Number
RSMV 3-RKMV 3-224/0.6M
RSMV 3-RKMV 3-224/1M
RSMV 3-RKMV 3-224/2M
60Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Pico M8 Double-Ended Cordsets
RSMV 3-RKMWV 3-224
Face View M8 Color Code
Description
Pico M8 actuator/sensor double-ended,
straight male to right-angle female cordset
with selflocking threaded joint and molded
cable, IP 67 / NEMA 6P rated.
Pin Assignments
Technical Data
Material
Molded body TPU
Insert PA / TPU
Contacts CuZn, pre-nickeled and
0.8 microns gold-plated
Receptacle shell CuZn, nickel plated
O-ring FKM
Electrical
Contact resistance ≤5mΩ
Current rating 4 A
Voltage rating 63 V
Test voltage 1.5 kV eff. / 60 s
Insulation resistance > 109 Ω
Mechanical
Temperature -25°C to + 80°C
Protection IP 67, NEMA 6P
Cable Specifications
Cable jacket PUR, halogen-free, black
Gauge 22 AWG
Outside diameter .185” (4.3 mm)
1 = brown3 = blue4 = black
Part Number
RSMV 3-RKMWV 3-224/0.6M
RSMV 3-RKMWV 3-224/1M
RSMV 3-RKMWV 3-224/2M
61www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Pico M8 Splitters
ASBS 2 M8
Face View M12 M8 Wiring Diagram
Description
Splitter with one Micro M12 male connector,
4-pole and two Pico M8 miniature female
connectors, 3 poles, with self locking threaded
joint.
Pin Assignments / Wiring Diagram
Technical Data
Material
Molded body TPU, self-extinguishing
Insert TPU, self-extinguishing
Contacts CuZn, pre-nickeled and
0.8 microns gold-plated
Receptacle shell CuZn, nickel plated
O-ring FKM
Electrical
Contact resistance ≤5mΩ
Current rating 4 A
Voltage rating 63 V
Test voltage M8:0.8 kV eff. / 60 s
M12: 1.5 kV eff. / 60 s
Insulation resistance > 109 Ω
Mechanical
Temperature -25°C to + 90°C
Protection IP 67, NEMA 6P
Part Number
ASBS 2 M8
Mutter schwarz Mutter vernickeltcoupling nut black coupling nut nickel-plated
A B
62Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Pico M8 Receptacles
RSMF 3
Face View M8 Color Code
Description
Pico M8 receptacle, male connector for front
mounting, assembled stranded wire, solder
contacts potted with epoxy, chassis side
thread M8 x 0.5 (panel nut RSKF 8).
Pin Assignments
Technical Data
Material
Molded body CuZn, nickel plated
Insert PA
Contacts CuZn, pre-nickeled and
0.8 microns gold-plated
O-ring FKM
Electrical
Contact resistance ≤5mΩ
Current rating 4 A
Voltage rating 60 V
Test voltage 1.5 kV eff. / 60 s
Insulation resistance > 109 Ω
Mechanical
Temperature -25°C to + 80°C
Protection IP 67, NEMA 6P
1 = brown3 = blue4 = black
Part Number
RSMF 3/0.5M
63www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Pico M8 Field Attachable Connectors
RKMCK 3 | RSMCK 3
Face View M8
Description
Pico M8 field attachable, female and male
with threaded joint, assembling with screw
terminals.
Pin Assignments
Technical Data
Material
Molded body PA
Insert TPU, self-extinguishing
Contacts CuZn, pre-nickeled and
0.8 microns gold-plated
Receptacle shell CuZn, nickel plated
O-ring FKM
Mode of connection Screw terminals
Cable gland 0.14-0.50 mm2
Electrical
Contact resistance ≤5mΩ
Current rating 4 A
Voltage rating 63 V
Test voltage 1.5 kV eff. / 60 s
Insulation resistance > 109 Ω
Mechanical
Temperature -40°C to + 85°C
Protection IP 67, NEMA 6P
Part Number
RKMCK 3
RSMCK 3
64Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Profibus® I/O Modules
0970 PSL 700 (16 In/ 16 Out Universal)
Description
Profibus-DP module with 16 digital I/O
channels, channels can be used universally as
inputs or outputs, M12 socket, rotary
switches for addressing, M12 bus connection,
7/8“ power supply.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments
Part Number
0970 PSL 700
Bit 7 6 5 4 3 2 1 0
M12 Input
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
Byte 1 8B 8A 7B 7A 6B 6A 5B 5A
M12 Output
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
Byte 1 8B 8A 7B 7A 6B 6A 5B 5A
Bus Connection M12 Power Supply 7/8” Input/Output M12
Pin Assignments
1 = +5 V 1
2 = Line A - GN3 = GND (0 V) 1
4 = Line B - RD5 = Earthhousing earth
1 = GND (O V) 2
2 = GND (0 V) 3
3 = earth4 = +24 V 3
5 = +24 V 2
1 = +24 V2 = IN/OUT B3 = GND (0 V)4 = IN/OUT A5 = earth 1 = internal signals: galvanically seperated to sensor/actuators
2 = actuators3 = system/sensors
Diagnostic Indication
LED Indication Condition
1...8 A/B yellow channel status
1...8 A/B DIA red periphery fault
US green sensor/system power supply
UL green actuator power supply
BF red bus error
DIA red common inidcation for periphery faults
65www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 380 g
Housing PBT
Bus System Profibus
ID number 09CA hex
GSD file Lum_09CA.gsd
Transmission rate max. 12 MBaud
Rotary address switches 1-125 dec
Default address 99 dec
System/Sensors Power Supply
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption 120 mA
Reverse polarity protection yes
Input Power Supply US
Voltage range min. (USystem - 1.5 V)
Sensor current 200 mA (at Tamb
30°C)
per socket
Short circuit-proof yes
Indication LED, green
Inputs Type 3 Acc. to
IEC 61131-2
Rated input voltage 24 V DC
Channel type N.O. P-switching
Number of digital channels max. 16
Channel status indicator LED, yellow per channel
Diagnosis indicator LED, red per socket
Output Power Supply UL
Rated voltage 24 V DC
Voltage range 19-30 V DC
Reverse polarity protection yes / antiparallel diode
Indication LED, green
Optional disengageable actuator low-voltage
detection over integrated DIP-switch.
Outputs
Rated output current 1.6 A per channel
Short circuit-proof yes
Max. output current 9 A per module
Overload-proof Yes
Number of digital channels max. 16
Channel type N.O. p-Switching
Channel status indicator LED, yellow per channel
Diagnostic indication LED, red per socket
Diagnostic
Module diagnostic and single channel diagnostic
according to Profibus specification (please see
operating instructions at www.beldensolutions.com/
service).
Included in delivery / accessories
Dust covers M12 4 pieces
Attachable labels 10 pieces
Profibus® I/O Modules - 0970 PSL 700 (16 In / 16 Out Universal)
66Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Profibus® I/O Modules
0970 PSL 701 (16 In)
Description
Profibus-DP module with 16 digital inputs to
connect standard sensors, M12 socket, rotary
switches for addressing, M12 bus connection,
7/8“ power supply.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0970 PSL 701
Bit 7 6 5 4 3 2 1 0
M12 Input
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
Byte 1 8B 8A 7B 7A 6B 6A 5B 5A
LED Indication Condition
1...8 A/B yellow channel status
1...8 A/B DIA red periphery fault
US green sensor/system power supply
BF red bus error
DIA red common inidcation for periphery faults
Bus Connection M12 Power Supply 7/8” Input/Output M12
Pin Assignments
1 = +5 V 1
2 = Line A - GN3 = GND (0 V) 1
4 = Line B - RD5 = Earthhousing earth
1 = GND (O V) 2 = GND (0 V) 3 = earth4 = 24 V 5 = -
1 = +24 V2 = IN B3 = GND (0 V)4 = IN A5 = earth 1 = internal signals: galvanically seperated to sensor/actuators
67www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 380 g
Housing PBT
Bus System Profibus
ID number 09CA hex
GSD file Lum_09CA.gsd
Transmission rate max. 12 MBaud
Rotary address switches 1-125 dec
Default address 99 dec
System/Sensors Power Supply
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption 120 mA
Reverse polarity protection yes
Input Power Supply US
Voltage range min. (USystem - 1.5 V)
Sensor current 200 mA (at Tamb
30°C)
per socket
Short circuit-proof yes
Indication LED, green
Inputs Type 3 Acc. to
IEC 61131-2
Rated input voltage 24 V DC
Channel type N.O. p-switching
Number of digital channels max. 16
Channel status indicator LED, yellow per channel
Diagnosis Indicator LED, red per socket
Diagnostic
Module diagnostic and single channel diagnostic
according to Profibus specification (please see
operating instructions at www.beldensolutions.com/
service).
Included in delivery / accessories
Dust covers M12 4 pieces
Attachable labels 10 pieces
Profibus® I/O Modules - 0970 PSL 701 (16 In)
68Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Profibus® I/O Modules
0970 PSL 650 (8 In / 8 Out Universal)
Description
Profibus-DP module with 8 digital I/O
channels, channels can be used universally as
inputs or outputs, M8 socket, 3 poles, rotary
switches for addressing, M12 bus connection,
M12 power supply.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0970 PSL 650
Bit 7 6 5 4 3 2 1 0
M8 Input
Byte 0 8 7 6 5 4 3 2 1
M8 Output
Byte 0 8 7 6 5 4 3 2 1
LED Indication Condition
1...8 yellow channel status
1...8 red periphery fault
US green sensor/system power supply
UL green actuator power supply
BF red bus error
DIA red common inidcation for periphery faults
Bus Connection M12 Power Supply M12 Input/Output M8
Pin Assignments
1 = +5 V 1
2 = Line A 3 = GND (0 V) 1
4 = Line B 5 = Earthhousing earth
1 = +24 V 3
3 = GND (0 V)4 = IN/OUT
1 = +24 V 2
2 = +24 V 3
3 = GND (0 V) 2
4 = GND (0 V) 3
5 = earth 1 = internal signals: galvanically seperated to sensor/actuators2 = actuators3 = system/sensors
69www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 200 g
Housing PBT
Bus System Profibus
ID number 09C9 hex
GSD file Lum_09C9.gsd
Transmission rate max. 12 MBaud
Address range 1-125 dec
Rotary address switches 1-99 dec
Default address 99 dec
System/Sensors Power Supply
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption 90 mA
Reverse polarity protection yes
Input Power Supply US
Voltage range min. (USystem - 1.5 V)
Sensor current 200 mA (at Tamb
30°C)
per socket
Short circuit-proof yes
Indication LED, green
Inputs Type 3 Acc. to
IEC 61131-2
Rated input voltage 24 V DC
Channel type N.O. p-switching
Number of digital channels max. 8
Channel status ndicator LED, yellow per channel
Diagnosis indicator LED, red per socket
Output Power Supply UL
Rated voltage 24 V DC
Voltage range 19-30 V DC
Reverse polarity protection yes / antiparallel diode
Indication LED, green
Outputs
Rated output current 0.5 A per channel
Short circuit-proof yes
Max. output current 4 A per module
Overload-proof Yes
Number of digital channels max. 8
Channel type N.O. p-switching
Channel status indicator LED, yellow per channel
Diagnostic indication LED, red per socket
Diagnostic
Module diagnostic and single channel diagnostic
according to Profibus specification (please see
operating instructions at www.beldensolutions.com/
service).
Included in delivery / accessories
Dust covers M8 2 pieces
Attachable labels 10 pieces
Profibus® I/O Modules - 0970 PSL 650 (8 In / 8 Out Universal)
70Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Profibus® I/O Modules
0970 PSL 651 (8 In)
Description
Profibus-DP module with 8 digital
inputs to connect standard sensors, M8 socket,
3 poles, rotary switches for addressing,M12 bus
connection, M12 power supply.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0970 PSL 651
Bit 7 6 5 4 3 2 1 0
M8 Input
Byte 0 8 7 6 5 4 3 2 1
LED Indication Condition
1...8 yellow channel status
1...8 red periphery fault
US green sensor/system power supply
BF red bus error
DIA red common inidcation for periphery faults
Bus Connection M12 Power Supply M12 Input M8
Pin Assignments
1 = +5 V 1
2 = Line A 3 = GND (0 V) 1
4 = Line B 5 = Earthhousing earth
1 = +24 V 2
3 = GND (0 V)4 = IN
1 = n.c.2 = +24 V 2
3 = n.c.4 = GND (0 V) 2
5 = earth 1 = internal signals: galvanically seperated to sensor/actuators2 = system/sensors
71www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 200 g
Housing PBT
Bus System Profibus
ID number 09C9 hex
GSD file Lum_09C9.gsd
Transmission rate max. 12 MBaud
Address range 1-125 dec
Rotary address switches 1-99 dec
Default address 99 dec
System/Sensors Power Supply
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption 90 mA
Reverse polarity protection yes
Input Power Supply US
Voltage range min. (USystem - 1.5 V)
Sensor current 100 mA (at Tamb 30°C)
per socket
Short circuit-proof yes
Indication LED, green
Inputs Type 3 Acc. to
IEC 61131-2
Rated input voltage 24 V DC
Channel type N.O. p-switching
Number of digital channels max. 8
Channel status indicator LED, yellow per channel
Diagnosis indicator LED, red per socket
Diagnostic
Module diagnostic and single channel diagnostic
according to Profibus specification (please see
operating instructions at www.beldensolutions.com/
service).
Included in delivery / accessories
Dust covers M8 2 pieces
Attachable labels 10 pieces
Profibus® I/O Modules - 0970 PSL 651 (8 In)
72Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Profibus® Single-Ended Signal Bus Cordsets
0975 254 103 | 0975 254 102
Description
Profibus signal bus cordsets, single-ended
with female or male M12 connector, 5 pole, B
coding.
Part Number
0975 254 103/2M
0975 254 103/3M
0975 254 103/4M
0975 254 103/5M
0975 254 102/2M
0975 254 102/3M
0975 254 102/4M
0975 254 102/5M
Technical Data
Conductor 0.34 mm2 (AWG 22)
bare, fine stranded
wires acc. to VDE 0295 KL5
Insulation of conductor SKIN-PE
Shielding Al-Pt-Foil
Filler cord 0.34 mm2 tin-coated, fine
wires acc. to VDE 0295 KL5
Overall shielding C-screen tinned, coverage
ca. 85 %
Outer jacket PUR dull, Ø 8,0 mm
color: purple RAL 4008
Electrical Data
Nominal voltage ≤250 V
Test voltage 2 kV eff.
Resistance of conductor ≤ 60 Ω/km
Insulation resistance ≥ 2,5 • 109 Ω/km
Operating capacity ≤ 25 pF/m 800 Hz (A/A)
Wave impedance 160 Ω ± 10%
Mechanical data
Bending radius suitable for C-tracks min
100 mm
Temperature static - 40° C to + 80° C
Temperature moving - 5° C to +80° C
Further details
Meets Profibus-DP specification
Inflammability acc. to DIN VDE 0472-804 test type B
Free of halogen, silicone, PVC
Good resistance to oil, chemicals, hydrolysis and
microbes
Face View M12 - B Coding M12 Male/Female Connector, 5-Pole Function Color
Pin 1 n.c. -Pin 2 Line A greenPin 3 n.c.Pin 4 Line B redPin 5 n.c.
Pin Assignments / Wiring
73www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Profibus® Double-Ended Signal Bus Cordsets
0975 254 101
Description
Profibus signal bus cordsets, double-ended
with female and male M12 connector, 5 pole,
B coding.
Part Number
0975 254 101/2M
0975 254 101/3M
0975 254 101/4M
0975 254 101/5M
Technical Data
Conductor 0.34 mm2 (AWG 22)
bare, fine stranded
wires acc. to VDE 0295 KL5
Insulation of conductor SKIN-PE
Shielding Al-Pt-Foil
Filler cord 0.34 mm2 tin-coated, fine
wires acc. to VDE 0295 KL5
Overall shielding C-screen tinned, coverage
ca. 85 %
Outer jacket PUR dull, Ø 8,0 mm
color: purple RAL 4008
Electrical Data
Nominal voltage ≤250 V
Test voltage 2 kV eff.
Resistance of conductor ≤ 60 Ω/km
Insulation resistance ≥ 2,5 • 109 Ω/km
Operating capacity ≤ 25 pF/m 800 Hz (A/A)
Wave impedance 160 Ω ± 10%
Mechanical data
Bending radius suitable for C-tracks min
100 mm
Temperature static - 40° C to + 80° C
Temperature moving - 5° C to +80° C
Further details
Meets Profibus-DP specification
Inflammability acc. to DIN VDE 0472-804 test type B
Free of halogen, silicone, PVC
Good resistance to oil, chemicals, hydrolysis and
microbes
Face View M12 - B Coding M12 Male/Female Connector, 5-Pole Function Color
Pin 1 n.c. -Pin 2 Line A greenPin 3 n.c.Pin 4 Line B redPin 5 n.c.
Pin Assignments / Wiring
74Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Profibus® Single-Ended Signal Bus Cordsets
0975 254 104 | 0975 254 105
Description
Profibus signal bus cordsets, double-ended
with female or male M12 connector, 5-Pole, B
coding to male SUB-D, 9 pole with switchable
terminating resistor.
Part Number
0975 254 104/2M
0975 254 104/3M
0975 254 104/4M
0975 254 104/5M
0975 254 105/2M
0975 254 105/3M
0975 254 105/4M
0975 254 105/5M
Technical Data
Conductor 0.34 mm2 (AWG 22)
bare, fine stranded
wires acc. to VDE 0295 KL5
Insulation of conductor SKIN-PE
Shielding Al-Pt-Foil
Filler cord 0.34 mm2 tin-coated, fine
wires acc. to VDE 0295 KL5
Overall shielding C-screen tinned, coverage
ca. 85 %
Outer jacket PUR dull, Ø 8,0 mm
color: purple RAL 4008
Electrical Data
Nominal voltage ≤250 V
Test voltage 2 kV eff.
Resistance of conductor ≤ 60 Ω/km
Insulation resistance ≥ 2,5 • 109 Ω/km
Operating capacity ≤ 25 pF/m 800 Hz (A/A)
Wave impedance 160 Ω ± 10%
Mechanical data
Bending radius suitable for C-tracks min
100 mm
Temperature static - 40° C to + 80° C
Temperature moving - 5° C to +80° C
Further details
Meets Profibus-DP specification
Inflammability acc. to DIN VDE 0472-804 test type B
Free of halogen, silicone, PVC
Good resistance to oil, chemicals, hydrolysis and
microbes
Face View M12 - B Coding M12 Male/Female Connector, 5-Pole Function Color
Pin 1 n.c. -Pin 2 Line A greenPin 3 n.c.Pin 4 Line B redPin 5 n.c.
Pin Assignments / Wiring
75www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Profibus® Single- and Double-Ended Power Supply Cordsets
0905 204 301 | 0905 204 302
Description
0905 204 301
Single-Ended Power supply cordset for
Profibus Modules 0970 PSL 70.... with female
Mini 7/8” Connector
0905 204 302
Double-Ended Power supply cordset for
Profibus Modules 0970 PSL 70.... with male and
female Mini 7/8” Connector
Part Number
0905 204 301/5M
0905 204 301/10M
0905 204 301/15M
0905 204 302/0.6M
0905 204 302/10M
Face View Mini 7/8” Mini Male/Female Connector, 5-Pole Leads
Pin 1 1Pin 2 2Pin 3 green/yellowPin 4 3Pin 5 4
Pin Assignments / Wiring
76Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Profibus® Field Attachable Connectors
0976 PFC 101 | 0976 PMC 101
Description
Profibus female and male field attachable
connectors, 5- pole, B coding for signal cable
0975 254 000/...M.
Part Number
0976 PFC 101
0976 PMC 101
Technical Data
Temperature Range - 25° C to + 90° C
Materials
Housing / Molded body GD-ZnAl, pre-coppered
and nickel-plated
Insert PBT
Contact CuZn, pre-coppered
Receptacle shell CuZn, nickel-plated
Shield sleeve CuBe, tin-plated
O-ring FKM
Mechanical Data
Degree of protection IP 67
Mode of connection Screw terminals
Connectable conductor max. 0.75 mm2
Screw joint for cable Ø 4,0–9,0 mm
Electrical Data
Contact resistance ≤ 5 mΩ
Nominal current @ 40° C 4 A
Nominal voltage 60 V
Rated voltage 63 V
Test voltage 1.0 kV eff. / 60 s
Insulation resistance > 109 Ω
Face View M12 - B Coding
Pin Assignments
77www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Profibus® Terminating Resistors
0979 PTX 101
Description
Profibus terminating resistor (plug), M12
4-pole, B coding.
Part Number
0976 PTX 101
78Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 501
Description
AS-Interface module with 4 digital inputs
(PNP) to connect M8 standard sensors, M8
bus connection.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0910 ASL 501
Diagnostic Indication
LED Indication Condition
1...4 yellow channel status
green slave is involved in data transfer
AS-i-DIAred communications error, no data transfer (e.g. slave address 0)
red flashing periphery error (e.g. sensor supply overload or short circuit)
Bus Connection M8 Input M8
Pin Assignments
Bit Assignments
Bit — — — — 3 2 1 0
M12 Input
Byte 0 — — — — I-4 I-3 I-2 I-1
1 = AS-Interface +3 = AS-Interface -4 = n.c.
1 = +24 V3 = GND (0 V)4 = IN
79www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Operating temperature range -25°C / +80°C
Weight 200 g
Housing material PUR
Bus System AS-Interface V 2.1
AS-Interface profile S 0.A.E
I/O configuration 0 hex
ID code A hex
ID2 code (extended ID-code) E hex
Support A/B addressing yes
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 250 mA
Reverse polarity protection yes
Indication LED green
Input Power Supply
Voltage range (AS-Interface net) 17–30 V
Total current of all sensors max. 200 mA
Short circuit-proof yes
Inputs Type 2 acc. to
IEC 61131-2
Rated input voltage 2 24 V DC
Signal state “1” Us>11 V / Is > 6 mA
Signal state “0” Is < 2 mA
Input current at 24 V 15 mA
Input circuit p-switching
Number of digital channels 4
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
AS-Interface I/O Modules - 0910 ASL 501
80Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 409 (version 2.1 - 4 in)
Description
AS-Interface flat cable module with 4 digital
inputs (PNP) to connect standard sensors,
combined M12 socket, infrared interface for
the addressing.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0910 ASL 409
Diagnostic Indication
LED Indication Condition
1...4 yellow channel status
U-AS-i green AS-Interface power supply active
FIDred communications error, no data transfer (e.g. slave address 0)
red flashing periphery error (sensor/actuator short circuit)
Input-1 M12 Input-2 M12 Input-3 M12 Input-4 M12
Pin Assignments
Bit Assignments
Bit — — — — 3 2 1 0
M12 Input
Byte 0 — — — — I-4 I-3/4 I-2 I-1/2
1 = +24 V2 = IN 23 = GND (0 V)4 = IN 15 = earth
1 = +24 V2 = n.c.3 = GND (0 V)4 = IN 25 = earth
1 = +24 V2 = IN 43 = GND (0 V)4 = IN 35 = earth
1 = +24 V2 = n.c.3 = GND (0 V)4 = IN 35 = earth
NOTE: The connection to earth for the inputs is implemented via the earthing contacts at the fastening holes.
81www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -15°C / +60°C
Weight 100 g
Housing PUR
Bus System AS-Interface V 2.1
AS-Interface profile S 0.A.E
I/O configuration 0 hex
ID code A hex
ID2 code (extended ID-code) E hex
Support A/B addressing yes
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 120 mA
Reverse polarity protection yes
Indication LED green
Input Power Supply
Voltage range (AS-Interface net) 17–30 V
Total current of all sensors max. 100 mA
Short circuit-proof yes
Inputs Type 2 acc. to
IEC 61131-2
Rated input voltage 2 24 V DC
Signal state “1” Us>11 V / Is > 6 mA
Signal state “0” Is < 2 mA
Input current at 24 V 15 mA
Input circuit p-switching
Number of digital channels 4
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
Note
The input channels are connected together. That
allows a greater connection flexibility (see pin
assignment). In case of connection of a two-channel
sensor to input socket 1 or 3 a further sensor must
not be plugged to input socket 2 or 4 respectively
due to the Y wiring of the inputs.
AS-Interface I/O Modules - 0910 ASL 409 (version 2.1 - 4 In)
82Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 132 (4 In)
Description
AS-Interface module with 4 digital inputs
(PNP) to connect standard sensors, M12 socket,
M12 bus connection.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number Replaces
0910 ASL 132 0910 ASL 112
Diagnostic Indication
LED Indication Condition
I-1...4 yellow channel status
U-AS-i green AS-Interface power supply active
Bus Connection M12 Input M12
Pin Assignments
Bit Assignments
Bit — — — — 3 2 1 0
M12 Input
Byte 0 — — — — I-4 I-3 I-2 I-1
1 = AS-Interface +2 = n.c.3 = AS-Interface -4 = n.c.
1 = +24 V2 = IN3 = GND (0 V)4 = IN5 = n.c.
83www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -25°C / +60°C
Weight 200 g
Housing PUR
Bus System AS-Interface
AS-Interface profile S 0.0.F
I/O configuration 0 hex
ID code 0 hex
ID2 code (extended ID-code) F hex
Support A/B addressing no
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 250 mA
Reverse polarity protection yes
Indication LED green
Input Power Supply
Voltage range (AS-Interface net) 17–30 V
Total current of all sensors max. 200 mA
Short circuit-proof yes
Inputs Type 2 acc. to
IEC 61131-2
Rated input voltage 2 24 V DC
Signal state “1” Us>11 V / Is > 6 mA
Signal state “0” Is < 2 mA
Input current at 24 V 15 mA
Input circuit p-switching
Number of digital channels 4
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Connection via cordset, double-ended
M12 / M12 0915 034 101/... M
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
AS-Interface I/O Modules - 0910 ASL 132 (4 In)
84Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 412 (version 2.1 - 8 In)
Description
AS-Interface flat cable module with 8 digital
inputs (PNP) to connect standard sensors, M12
socket, infrared interface for the addressing.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0910 ASL 412
Pin Assignments
Bit Assignments
Bit — — — — 3 2 1 0
M12 Input
Byte 0 / Slave 1 — — — — I-4 I-3 I-2 I-1
Byte 1 / Slave 2 — — — — I-4 I-3 I-2 I-1
Diagnostic Indication
LED Indication Condition
1...4 yellow channel status
U-AS-i green AS-Interface power supply active
FIDred communications error
red flashing periphery error (sensor/actuator short circuit)
Input-1 M12 Input-2 M12 Input-3 M12 Input-4 M12
1 = +24 V2 = IN 23 = GND (0 V)4 = IN 15 = earth
1 = +24 V2 = n.c.3 = GND (0 V)4 = IN 25 = earth
1 = +24 V2 = IN 43 = GND (0 V)4 = IN 35 = earth
1 = +24 V2 = n.c.3 = GND (0 V)4 = IN 45 = earth
85www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -25°C / +80°C
Weight 300 g
Housing PUR
Bus System AS-Interface V 2.1
AS-Interface profile S 0.1.E
I/O configuration 0 hex
ID code 1 hex
ID2 code (extended ID-code) E hex
Support A/B addressing no
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 500 mA
Reverse polarity protection yes
Indication LED green
Input Power Supply
Voltage range (AS-Interface net) 17–30 V
Total current of all sensors max. 200 mA
Short circuit-proof yes
Inputs Type 2 acc. to
IEC 61131-2
Rated input voltage 2 24 V DC
Signal state “1” Us>11 V / Is > 6 mA
Signal state “0” Is < 2 mA
Input current at 24 V 15 mA
Input circuit p-switching
Number of digital channels 8
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
Note
The input channels are connected together. That
allows a greater connection flexibility (see pin
assignment). In case of connection of a two-channel
sensor to input socket 1 or 3 a further sensor must
not be plugged to input socket 2 or 4 respectively
due to the Y wiring of the inputs.
AS-Interface I/O Modules - 0910 ASL 412 (version 2.1 - 8 In)
86Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 403 (4 Out)
Description
AS-Interface flat cable module with 4 digital
outputs (2 A) to connect standard actuators,
M12 socket.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0910 ASL 403
Pin Assignments
Bit Assignments
Bit — — — — 3 2 1 0
M12 Output
Byte 0 — — — — O-4 O-3 O-2 O-1
Diagnostic Indication
LED Indication Condition
O-1...4 yellow channel status
U-AS-i green AS-Interface power supply active
AUX green actuator supply active
Output M12
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT5 = earth
87www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -25°C / +80°C
Weight 200 g
Housing PUR
Bus System AS-Interface
AS-Interface profile 8.0
I/O configuration 8 hex
ID code 0 hex
Support A/B addressing no
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 75 mA
Reverse polarity protection yes
Indication LED green
Output Power Supply AUX
Rated voltage 24 V DC
Voltage range 10–30 V
Potential separation present
Reverse polarity protection yes/electronic
Indication LED green
Outputs Type 2 acc. to
IEC 61131-2
Rated output current 2 A per channel
Short circuit-proof yes
Max. output current 4 A per module
Overload-proof yes
Number of digital channels 4
Channel type N.O. p-switching
Channel status indicator LED yellow per
channel
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
AS-Interface I/O Modules - 0910 ASL 403 (4 Out)
88Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 133 (4 Out)
Description
AS-Interface module with 4 digital outputs to
connect standard actuators, M12 socket, M12
bus connection.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number Replaces
0910 ASL 133 0910 ASL 111
Pin Assignments
Bit Assignments
Bit — — — — 3 2 1 0
M12 Output
Byte 0 — — — — O-4 O-3 O-2 O-1
Diagnostic Indication
LED Indication Condition
O-1...4 yellow channel status
U-AS-i green AS-Interface power supply active
AUX green actuator supply active
Output M12 Output M12
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT5 = earth
1 = AS-Interface +2 = 0 V AUX3 = AS-Interface -4 = +24 V AUX
89www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -25°C / +80°C
Weight 200 g
Housing PUR
Bus System AS-Interface
AS-Interface profile S 8.0.F
I/O configuration 8 hex
ID code 0 hex
Support A/B addressing no
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 75 mA
Reverse polarity protection yes
Indication LED green
Output Power Supply AUX
Rated voltage 24 V DC
Voltage range 10–30 V
Potential separation present
Reverse polarity protection yes/electronic
Indication LED green
Outputs Type 2 acc. to
IEC 61131-2
Rated output current 2 A per module
Short circuit-proof yes
Max. output current 4 A per module
Overload-proof yes
Number of digital channels 4
Channel type N.O. p-switching
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Connection via cordset, double-ended
M12 / M12 0915 034 101/...M
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
AS-Interface I/O Modules - 0910 ASL 133 (4 Out)
90Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 419 (version 2.1 - 8 Out)
Description
AS-Interface flat cable module with 8 digital
outputs (0.5 A, Y connected) to connect
standard actuators, M12 socket, infrared
interface for the addressing.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0910 ASL 419
Pin Assignments
Bit Assignments
Bit — — — — 3 2 1 0
M12 Output
Byte 0 / Slave 1 — — — — O-4 O-3 O-2 O-1
Byte 0 / Slave 2 — — — — O-4 O-3 O-2 O-1
Diagnostic Indication
LED Indication Condition
O-1...4 yellow channel status
AS-i green AS-Interface power supply active
AUX green actuator supply active
red communication error
FID red flashing periphery error (actuator short circuit)
Output-1 M12 Output-2 M12 Output-3 M12 Output-4 M12
1 = n.c.2 = OUT 23 = GND (0 V)4 = OUT 15 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 25 = earth
1 = n.c.2 = OUT 43 = GND (0 V)4 = OUT 35 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 45 = earth
NOTE: The connection to earth for the inputs and outputs is implemented via the earthing contacts at the fastening holes.
91www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface I/O Modules - 0910 ASL 419 (version 2.1 - 8 Out)
Technical Data
Degree of protection IP 67
Temperature range -25°C / +80°C
Weight 300 g
Housing PUR
Bus System AS-Interface V 2.1
AS-Interface profile S 8.1.F
I/O configuration 8 hex
ID code 1 hex
ID2 code (extended ID-code) E hex
Support A/B addressing no
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 75 mA
Reverse polarity protection yes
Indication LED green
Output Power Supply AUX
Rated voltage 24 V DC
Voltage range 10–30 V
Potential separation present
Reverse polarity protection yes/electronic
Indication LED green
Outputs Type 2 A acc. to
IEC 61131-2
Rated output current 0.5 A per channel
Short circuit-proof yes
Max. output current 4 A per module
Overload-proof yes
Number of digital channels 8
Channel type N.O. p-switching
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
Note
The output channels are connected together. That
allows a greater connection flexibility (see pin
assignment). When actuators are connected, this Y
wiring of the terminal sockets has to be taken
into consideration with respect to current load.
92Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 410 (version 2.1 - 2 In / 2 Out)
Description
AS-Interface flat cable module with 2 digital
inputs to connect standard sensors and
2 digital outputs to connect standard
actuators, M12 socket, infrared
interface for the addressing.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0910 ASL 410
Pin Assignments
Bit Assignments
Bit — — — — 3 2 1 0
M12 Input
Byte 0 — — — — — — I-2 I-1/2
M12 Output
Byte 0 — — — — O-4 O-3 — —
Diagnostic Indication
LED Indication Condition
I-1...2 / O-3...4 yellow channel status
U-AS-i green AS-Interface power supply active
AUX green actuator supply active
red communication error
FID red flashing periphery error (actuator short circuit)
Input-1 M12 Input-2 M12 Output-3 M12 Output-4 M12
1 = + 24 V2 = IN 23 = GND (0 V)4 = IN 15 = earth
1 = + 24 V2 = n.c.3 = GND (0 V)4 = IN 25 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 35 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 45 = earth
NOTE: The connection to earth for the inputs and outputs is implemented via the earthing contacts at the fastening holes.
93www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface I/O Modules - 0910 ASL 410 (version 2.1 - 2 In / 2 Out)
Technical Data
Degree of protection IP 67
Temperature range -25°C / +80°C
Weight 200 g
Housing PUR
Bus System AS-Interface V 2.1
AS-Interface profile S 3.F.E
I/O configuration 3 hex
ID code F hex
ID2 code (extended ID-code) E hex
Support A/B addressing no
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 250 mA
Reverse polarity protection yes
Indication LED green
Input Power Supply
Voltage range (AS-Interface net) 17–30 V
Total current of all sensors max. 200 mA
Short circuit-proof yes
Inputs Type 2 acc. to
IEC 61131-2
Rated input voltage 2 24 V DC
Signal state “1” Us>11 V / Is > 6 mA
Signal state “0” Is < 2 mA
Input current at 24 V 15 mA
Input circuit p-switching
Number of digital channels 2
Channel status indicator LED yellow per
channel
Output Power Supply AUX
Rated voltage 24 V DC
Voltage range 10–30 V
Potential separation present
Reverse polarity protection yes/electronic
Indication LED green
Outputs Type 2 A acc. to
IEC 61131-2
Rated output current 2 A per module
Short circuit-proof yes
Max. output current 4 A per module
Overload-proof yes
Number of digital channels 2
Channel type N.O. p-switching
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
Note
The input channels are connected together. That
allows a greater connection flexibility (see pin
assignment). In case of connection of a two-channel
sensor to input socket 1 a further sensor must not be
plugged to input socket 2 respectively due to the Y
wiring of the inputs.
94Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 134 (2 In / 2 Out)
Description
AS-Interface module with 2 digital inputs to
connect standard sensors and 2 digital
outputs to connect standard actuators, M12
socket, M12 bus connection.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number Replaces
0910 ASL 134 0910 ASL 110
Pin Assignments
Bit Assignments
Bit — — — — 3 2 1 0
M12 Input
Byte 0 — — — — — — I-2 I-1
M12 Output
Byte 0 — — — — O-4 O-3 — —
Diagnostic Indication
LED Indication Condition
I-1...2 / O-3...4 yellow channel status
U-AS-i green AS-Interface power supply active
AUX green actuator supply active
Bus Connection M12 Input M12 Output M12
1 = AS-Interface +2 = 0 V AUX3 = AS-Interface -4 = +24 V AUX
1 = +24 V2 = IN3 = GND (0 V)4 = IN5 = n.c.
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT5 = earth
95www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface I/O Modules - 0910 ASL 134 (2 In / 2 Out)
Technical Data
Degree of protection IP 67
Temperature range -25°C / +80°C
Weight 200 g
Housing PUR
Bus System AS-Interface
AS-Interface profile S 3.0.F
I/O configuration 3 hex
ID code 0 hex
ID2 code (extended ID-code) F hex
Support A/B addressing no
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 250 mA
Reverse polarity protection yes
Indication LED green
Input Power Supply
Voltage range (AS-Interface net) 17-30 V
Total current of all sensors max. 200 mA
Short circuit-proof yes
Inputs Type 2 acc. to
IEC 61131-2
Rated input voltage 2 24 V DC
Signal state “1” Us>11 V / Is > 6 mA
Signal state “0” Is < 2 mA
Input current at 24 V 15 mA
Input circuit p-switching
Number of digital channels 2
Channel status indicator LED yellow per
channel
Output Power Supply AUX
Rated voltage 24 V DC
Voltage range 10–30 V
Potential separation present
Reverse polarity protection yes/electronic
Indication LED green
Outputs Type 2 A acc. to
IEC 61131-2
Rated output current 2 A per module
Short circuit-proof yes
Max. output current 4 A per module
Overload-proof yes
Number of digital channels 2
Channel type N.O. p-switching
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
Connection via cordset, double-ended
M12 / M12 0915 034 101/...M
96Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 414 (version 2.1 - 4 In / 3 Out)
Description
AS-Interface flat cable module with 4 digital
inputs (Y connected) to connect standard
sensors and 3 digital outputs (2 A) to connect
standard actuators, M12 socket, infrared
interface for the addressing and support of the
extended addressing mode.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0910 ASL 414
Bit Assignments
Bit — — — — 3 2 1 0
M12 Input
Byte 0 — — — — I-4 I-3/4 I-2 I-1/2
M12 Output
Byte 0 — — — — — O-3 O-2 O-1
Diagnostic Indication
LED Indication Condition
I-1...4 / O-1...3 yellow channel status
U-AS-i green AS-Interface power supply active
AUX green actuator supply active
red communication error
FID red flashing periphery error (actuator short circuit / sensor supply error)
Pin Assignments
Input-1 M12 Input-2 M12 Input-3 M12 Input-4 M12
Output-1 M12 Output-2 M12 Output-3 M12
1 = + 24 V2 = IN 23 = GND (0 V)4 = IN 15 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 15 = earth
1 = + 24 V2 = n.c.3 = GND (0 V)4 = IN 25 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 25 = earth
1 = + 24 V2 = IN 43 = GND (0 V)4 = IN 35 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 35 = earth
1 = + 24 V2 = n.c.3 = GND (0 V)4 = IN 45 = earth
NOTE: The connection to earth for the outputs is implemented via the earthing contacts at the fastening holes.
97www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface I/O Modules - 0910 ASL 414 (version 2.1 - 4 In / 3 Out)
Technical Data
Degree of protection IP 67
Temperature range -25°C / +80°C
Weight 300 g
Housing PUR
Bus System AS-Interface V 2.1
AS-Interface profile S 7.A.E
I/O configuration 7 hex
ID code A hex
ID2 code (extended ID-code) E hex
Support A/B addressing yes
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 100 mA
Reverse polarity protection yes
Indication LED green
Input Power Supply
Voltage range (AS-Interface net) 17-30 V
Total current of all sensors max. 100 mA
Short circuit-proof yes
Inputs Type 2 acc. to
IEC 61131-2
Rated input voltage 2 24 V DC
Signal state “1” Us>11 V / Is > 6 mA
Signal state “0” Is < 1.5 mA
Input current at 24 V 15 mA
Input circuit p-switching
Number of digital channels 4
Channel status indicator LED yellow per
channel
Output Power Supply AUX
Rated voltage 24 V DC
Voltage range 10–30 V
Potential separation present
Reverse polarity protection yes/electronic
Indication LED green
Outputs Type 2 A acc. to
IEC 61131-2
Rated output current 2 A per channel
Short circuit-proof yes
Max. output current 4 A per module
Overload-proof yes
Number of digital channels 3
Channel type N.O. p-switching
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
Note
The input channels are connected together. That
allows a greater connection flexibility (see pin
assignment). In case of connection of a two-channel
sensor to input socket 1 or 3 a further sensor must
not be plugged to input socket 2 or 4 respectively
due to the Y wiring of the inputs.
98Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 408 (version 2.1 - 4 In / 4 Out)
Description
AS-Interface flat cable module with 4 digital
inputs to connect standard sensors and 4
digital outputs to connect standard actuators,
M12 socket, infrared interface for the
addressing.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0910 ASL 408
Bit Assignments
Bit — — — — 3 2 1 0
M12 Input
Byte 0 — — — — I-4 I-3/4 I-2 I-1/2
M12 Output
Byte 0 — — — — O-4 O-3 O-2 O-1
Diagnostic Indication
LED Indication Condition
I-1...4 / O-1...4 yellow channel status
U-AS-i green AS-Interface power supply active
AUX green actuator supply active
red communication error
FID red flashing periphery error (sensor/actuator short circuit)
Pin Assignments
Input-1 M12 Input-2 M12 Input-3 M12 Input-4 M12
Output-1 M12 Output-2 M12 Output-3 M12 Output-3 M12
1 = + 24 V2 = IN 23 = GND (0 V)4 = IN 15 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 15 = earth
1 = + 24 V2 = n.c.3 = GND (0 V)4 = IN 25 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 25 = earth
1 = + 24 V2 = IN 43 = GND (0 V)4 = IN 35 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 35 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 45 = earth
1 = + 24 V2 = n.c.3 = GND (0 V)4 = IN 45 = earth
NOTE: The connection to earth for the inputs and outputs is implemented via the earthing contacts at the fastening holes.
99www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface I/O Modules - 0910 ASL 408 (version 2.1 - 4 In / 4 Out)
Technical Data
Degree of protection IP 67
Temperature range -25°C / +80°C
Weight 300 g
Housing PUR
Bus System AS-Interface V 2.1
AS-Interface profile S 7.A.E
I/O configuration 7 hex
ID code F hex
ID2 code (extended ID-code) E hex
Support A/B addressing yes
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 250 mA
Reverse polarity protection yes
Indication LED green
Input Power Supply
Voltage range (AS-Interface net) 17-30 V
Total current of all sensors max. 200 mA
Short circuit-proof yes
Inputs Type 2 acc. to
IEC 61131-2
Rated input voltage 2 24 V DC
Signal state “1” Us>11 V / Is > 6 mA
Signal state “0” Is < 2 mA
Input current at 24 V 15 mA
Input circuit p-switching
Number of digital channels 4
Channel status indicator LED yellow per
channel
Output Power Supply AUX
Rated voltage 24 V DC
Voltage range 10–30 V
Potential separation present
Reverse polarity protection yes/electronic
Indication LED green
Outputs Type 2 A acc. to
IEC 61131-2
Rated output current 2 A per channel
Short circuit-proof yes
Max. output current 4 A per module
Overload-proof yes
Number of digital channels 4
Channel type N.O. p-switching
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
Note
The input channels are connected together. That
allows a greater connection flexibility (see pin
assignment). In case of connection of a two-channel
sensor to input socket 1 or 3 a further sensor must
not be plugged to input socket 2 or 4 respectively
due to the Y wiring of the inputs.
100Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 135 (4 In / 4 Out)
Description
AS-Interface module with 4 digital inputs to
connect standard sensors and 4 digital outputs
to connect standard actuators, M12 socket,
M12 bus connection.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number Replaces
0910 ASL 135 0910 ASL 109
Bit Assignments
Bit — — — — 3 2 1 0
M12 Input
Byte 0 — — — — I-4 I-3 I-2 I-1
M12 Output
Byte 0 — — — — O-4 O-3 O-2 O-1
Diagnostic Indication
LED Indication Condition
I-1...4 / O-1...4 yellow channel status
U-AS-i green AS-Interface power supply active
AUX green actuator supply active
Pin Assignments
Bus Connection M12 Input M12 Output M12
1 = +24 V2 = IN3 = GND (0 V)4 = IN5 = n.c.
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT5 = earth
1 = AS-Interface +2 = 0 V AUX3 = AS-Interface -4 = +24 V AUX
101www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface I/O Modules - 0910 ASL 135 (4 In / 4 Out)
Technical Data
Degree of protection IP 67
Temperature range -25°C / +80°C
Weight 200 g
Housing PUR
Bus System AS-Interface
AS-Interface profile S 7.0.E
I/O configuration 7 hex
ID code 0 hex
ID2 code (extended ID-code) F hex
Support A/B addressing no
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 250 mA
Reverse polarity protection yes
Indication LED green
Input Power Supply
Voltage range (AS-Interface net) 17-30 V
Total current of all sensors max. 250 mA
Short circuit-proof yes
Inputs Type 2 acc. to
IEC 61131-2
Rated input voltage 2 24 V DC
Signal state “1” Us>11 V / Is > 6 mA
Signal state “0” Is < 2 mA
Input current at 24 V 15 mA
Input circuit p-switching
Number of digital channels 4
Channel status indicator LED yellow per
channel
Output Power Supply AUX
Rated voltage 24 V DC
Voltage range 10–30 V
Potential separation present
Reverse polarity protection yes/electronic
Indication LED green
Outputs Type 2 A acc. to
IEC 61131-2
Rated output current 2 A per channel
Short circuit-proof yes
Max. output current 4 A per module
Overload-proof yes
Number of digital channels 4
Channel type N.O. p-switching
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Connection via cordset, double-ended
M12 / M12 0915 034 101/...M
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
102Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 146 (Version 3.0 - 4 In / 4 Out)
Description
AS-Interface flat cable module with 4 digital
inputs for 2-wire- or 3-wire sensors and 4
digital outputs to connect standard actuators,
combined FIXCON/M12 socket.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0910 ASL 146
Bit Assignments
Bit — — — — 3 2 1 0
M12 Input
Byte 0 — — — — I-4 I-3 I-2 I-1
M12 Output
Byte 0 — — — — O-4 O-3 O-2 O-1
Diagnostic Indication
LED Indication Condition
O-1...4 yellow channel status
U-AS-i green AS-Interface power supply active
AUX green actuator supply active
DIA red communication error
red flashing periphery error (sensor/actuator short circuit)
Pin Assignments
Input 1 M12 Input 2 M12 Input 3 M12 Input 4 M12
Output 1 M12 Output 2 M12 Output 3 M12 Output 4 M12
AS-i/Aux. PWR In (Plug M12) AS-i/Aux. PWR Out (Socket M12)
1 = +24 V2 = IN 23 = GND (0 V)4 = IN 15 = earth
1 = n.c.2 = OUT 23 = GND (0 V)4 = OUT 15 = earth
1 = AS-i (+)2 = Auxiliary power (-)3 = AS-i (-)4 = Auxiliary power (+)5 = n.c.
1 = +24 V2 = n.c.3 = GND (0 V)4 = IN 25 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 25 = earth
1 = AS-i (+)2 = Auxiliary power (-)3 = AS-i (-)4 = Auxiliary power (+)5 = n.c.
1 = +24 V2 = IN 43 = GND (0 V)4 = IN 35 = earth
1 = n.c.2 = OUT 43 = GND (0 V)4 = OUT 35 = earth
1 = +24 V2 = n.c.3 = GND (0 V)4 = IN 45 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 45 = earth
The connection to earth for the inputs and outputs is implemented via the earthing contacts at the fastening holes.
103www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface I/O Modules - 0910 ASL 146 (Version 3.0 - 4 In / 4 Out)
Technical Data
Degree of protection IP 67
Temperature range -25°C / +80°C
Weight 300 g
Housing PUR
Bus System AS-Interface V3.0
AS-Interface profile S 7.A.7
I/O configuration 7 hex
ID code A hex
ID2 code (extended ID-code) 7 hex
Support A/B addressing yes
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 250 mA
Reverse polarity protection yes
Indication LED green
Input Power Supply
Voltage range (AS-Interface net) 17-30 V
Total current of all sensors max. 250 mA
Short circuit-proof yes
Inputs Type 2 acc. to
IEC 61131-2
Rated input voltage 2 24 V DC
Signal state “1” Us>11 V / Is > 6 mA
Signal state “0” Is < 2 mA
Input current at 24 V 15 mA
Input circuit p-switching
Number of digital channels 4
Channel status indicator LED yellow per
channel
Output Power Supply AUX
Rated voltage 24 V DC
Voltage range 10–30 V
Potential separation present
Reverse polarity protection yes/electronic
Indication LED green
Outputs Type 2 A acc. to
IEC 61131-2
Rated output current 2 A per channel
Short circuit-proof yes
Max. output current 4 A per module
Overload-proof yes
Number of digital channels 4
Channel type N.O. p-switching
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
Note
The input- and output channels are connected
together. That allows a greater connection flexibility
(see pin assignment). In case of connection of a two-
channel sensor/actuator to input/output socket 1 or
3 a further sensor/actuator must not be plugged to
input/output socket 2 or 4 respectively due to the Y
wiring of the inputs/outputs.
104Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface I/O Modules
0910 ASL 438 (Version 3.0 - 4 In / 4 Out)
Description
AS-Interface flat cable module with 4 digital
inputs for 2-wire or 3-wire sensors and 4
digital outputs to connect standard actuators,
combined FIXCON/M12 socket, infrared
interface for the addressing.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0910 ASL 438
Bit Assignments
Bit — — — — 3 2 1 0
M12 Input
Byte 0 — — — — I-4 I-3/4 I-2 I-1/2
M12 Output
Byte 0 — — — — O-4 O-3/4 O-2 O-1/2
Diagnostic Indication
LED Indication Condition
I-1..4/O-1..4 yellow channel status
U-AS-i green AS-Interface power supply active
AUX green actuator supply active
FID red communication error
red flashing periphery error (sensor/actuator short circuit)
Pin Assignments
Input 1 M12 Input 2 M12 Input 3 M12 Input 4 M12
Output 1 M12 Output 2 M12 Output 3 M12 Output 4 M12
1 = +24 V2 = IN 23 = GND (0 V)4 = IN 15 = earth
1 = n.c.2 = OUT 23 = GND (0 V)4 = OUT 15 = earth
1 = +24 V2 = n.c.3 = GND (0 V)4 = IN 25 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 25 = earth
1 = +24 V2 = IN 43 = GND (0 V)4 = IN 35 = earth
1 = n.c.2 = OUT 43 = GND (0 V)4 = OUT 35 = earth
1 = +24 V2 = n.c.3 = GND (0 V)4 = IN 45 = earth
1 = n.c.2 = n.c.3 = GND (0 V)4 = OUT 45 = earth
The connection to earth for the inputs and outputs is implemented via the earthing contacts at the fastening holes.
105www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface I/O Modules - 0910 ASL 438 (Version 3.0 - 4 In / 4 Out)
Technical Data
Degree of protection IP 67
Temperature range -25°C / +80°C
Weight 300 g
Housing PUR
Bus System AS-Interface V3.0
AS-Interface profile S 7.A.7
I/O configuration 7 hex
ID code A hex
ID2 code (extended ID-code) 7 hex
Support A/B addressing yes
Electronics Power Supply AS-Interface
Rated voltage AS-Interface net
Voltage range 26.5–31.6 V DC
Power consumption max. 250 mA
Reverse polarity protection yes
Indication LED green
Input Power Supply
Voltage range (AS-Interface net) 17-30 V
Total current of all sensors max. 250 mA
Short circuit-proof yes
Inputs Type 2 acc. to
IEC 61131-2
Rated input voltage 2 24 V DC
Signal state “1” Us>11 V / Is > 6 mA
Signal state “0” Is < 2 mA
Input current at 24 V 15 mA
Input circuit p-switching
Number of digital channels 4
Channel status indicator LED yellow per
channel
Output Power Supply AUX
Rated voltage 24 V DC
Voltage range 10–30 V
Potential separation present
Reverse polarity protection yes/electronic
Indication LED green
Outputs Type 2 A acc. to
IEC 61131-2
Rated output current 2 A per channel
Short circuit-proof yes
Max. output current 4 A per module
Overload-proof yes
Number of digital channels 4
Channel type N.O. p-switching
Channel status indicator LED yellow per
channel
Diagnostic
Indication LED red
Included in delivery / accessories
Dust covers M12 2 pieces
Attachable labels 10 pieces
Note
The in- and output channels are connected together.
That allows a greater connection flexibility (see pin
assignment). In case of connection of a two-channel
sensor to input socket 1 or 3 a further sensor must
not be plugged to input socket 2 or 4 respectively
due to the Y wiring of the inputs.
106Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface Bulk Flat Cable
0915 097 000 | 0915 098 000
Description
0915 097 000
AS-Interface rubber flat cable; yellow outer
jacket for bus, 50 meter spool.
0915 098 000
AS-Interface rubber flat cable; black outer
jacket for auxiliary power, 50 meter spool.
Part Number
0915 097 000/50M
0915 098 000/50M
Technical Data
Operating Temperature -40°C / +80°C
Materials
Conductor 1.50 mm2, tin-coated, very
finely stranded wires acc.
to VDE 0295 KL6
Insulation of lead Rubber mixture
Color of leads brown/blue
Outer jacket Rubber mixture, color:
yellow or black
Electrical Data
Nominal voltage ≤ 300 V
Test voltage 2.0 kV eff. / 60 s
Insulation resistance ≤ 14 Ω/km
Mechanical Data
Tensile strength 50N/mm2 (during
installation)
Bending radius > 12 mm, static and freely
movable
> 16 mm, in case of
C-track operation
Further Details
Intended for indoor use. The use in open aire requires
conductors provided with black outer jacket.
107www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface Bulk Flat Cable
0915 146 000 | 0915 145 000
Description
0915 146 000
AS-Interface TPE flat cable; yellow outer jacket
for bus, 50 meter spool.
0915 145 000
AS-Interface TPE flat cable; black outer jacket
for auxiliary power, 50 meter spool.
Part Number
0915 146 000/50M
0915 145 000/50M
Technical Data
Operating Temperature -40°C / +90°C
Materials
Conductor 1.50 mm2, tin-coated, very
finely stranded wires acc.
to VDE 0295 KL6
Insulation of lead TPE
Color of leads brown/blue
Outer jacket TPE, color: yellow or black
Electrical Data
Nominal voltage ≤ 300 V
Test voltage 2.0 kV eff. / 60 s
Insulation resistance ≤ 14 Ω/km
Mechanical Data
Tensile strength 50N/mm2 (during
installation)
Bending radius > 12 mm, static and freely
movable
> 16 mm, in case of
C-track operation
Further Details
Resistance to oil acc. to DIN/VDE 0472-803.
Inflammability acc. to FH 2-25, in compliance with
IEC 707.
108Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface Passive Distribution Box
0911 ANC 002
Description
AS-Interface passive module to connect 4
AS-Interface sensors, AS-Interface actuators
or ASInterface round cable modules, 4 ports,
M12 socket, with connection for AS-Interface
standard round cables.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0911 ANC 002/5M
0911 ANC 002/10M
Technical Data
Operating Temperature -25°C / +80°C
Materials
Housing / Molded body PUR
Cable outer jacket PUR/PVC
Mechanical Data
Degree of protection IP 67
Cable Specification 0911 ANC 002: PUR/PVC -
cable-no. 41 Further
information please see
chapter “Cable
specifications”
Power Supply M23 Input M12
Pin Assignments
1 = AS-Interface +2 = GND (0 V)3 = AS-Interface -4 = + 24 V5 = earth
1 = earth2 = +24 V 3 = GND (0 V) 4 = n.c.5 = n.c.6 = n.c.
109www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface Passive Distribution Box
0911 ANC 403
Description
AS-Interface passive module to connect 4
AS-Interface sensors, AS-Interface actuators
or AS-Interface round cable modules, 4 ports,
M12 socket, with connection for AS-Interface
standard flat cables.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0911 ANC 403
Technical Data
Operating Temperature -25°C / +80°C
Materials
Housing / Molded body PUR
Mechanical Data
Degree of protection IP 67
Cable Specification 0911 ANC 002: PUR/PVC -
cable-no. 41 Further
information please see
chapter “Cable
specifications”
Input M12
Pin Assignments
1 = AS-Interface +2 = GND (0 V)3 = AS-Interface -4 = + 24 V5 = earth
110Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface Flat Cable Junctions
0911 ANC 101 | 0911 ANC 401
Description
0911 ANC 101
AS-Interface branch to connect AS-Interface
slaves via a M12 connector with a flat cable
system.
0911 ANC 401
AS-Interface branch to connect two flat
cables (opening of an AS-Interface branch or
additional voltage supply).
Part Number
0911 ANC 101
0911 ANC 401
Technical Data
Materials
Housing PUR
Mechanical Data
Degree of protection IP 65
Electrical
0911 ANC 001 4 A
0911 ANC 101 4 A
0911 ANC 401 8 A
Input M12 Cable
Pin Assignments
1 = AS-Interface +2 = GND (0 V)3 = AS-Interface -4 = + 24 V5 = earth
1 = AS-Interface + brown2 = GND (0 V) white 3 = AS-Interface - blue4 = + 24 V black 5 = earth green/yellow
111www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface Flat Cable Junctions
0911 ANC 407 | 0911 ANC 410
Description
0911 ANC 407
AS-Interface connector for direct connection
to a wired male connector: reusable access
technology to IEC 60352-6. AS-Interface
connector 0911 ANC 406 is included with the
delivered product.
0911 ANC 410
AS-Interface connector for direct connection
to two wired male connectors: reusable access
technology to IEC 60352-6. AS-Interface
connector 0911 ANC 406 is included with the
delivered product.
Part Number
0911 ANC 407/2M
0911 ANC 407/5M
0911 ANC 407/10M
0911 ANC 410/0.3M
0911 ANC 410/0.6M
0911 ANC 410/1M
0911 ANC 410/2M
0911 ANC 410/5M
0911 ANC 410/10M
0911 ANC 410/15M
Technical Data
Materials
Housing PA
Insert PUR
Mechanical Data
Degree of protection IP 67
Electrical 2 A per contact
2 Poles
Pin Assignments
1 = brown2 = blue
112Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface Flat Cable Junctions
0911 ANC 408 | 0911 ANC 406 | 0911 ANC 413 | 0911 ANC 415
Description
0911 ANC 408
AS-Interface cable connector, used for
distribution of connections or as connector:
reusable access technology to IEC 60352-
6. AS-Interface connector 0911 ANC 406 is
included with the delivered product.
0911 ANC 406
AS-Interface connector for AS-Interface
cables.
0911 ANC 413
AS-Interface cable connector, used for
distribution of connections or as connector:
reusable access technology to IEC 68 and
DIN 41611, hexagon screw in stainless steel, 4
poles. AS-Interface connector 0911 ANC 415 is
included with the delivered product.
0911 ANC 413
AS-Interface connector for AS-Interface cables
– especially designed for food and beverage
equipment.
Part Number
0911 ANC 408
0911 ANC 406
0911 ANC 413
0911 ANC 415
Technical Data
Materials
Housing
0911 ANC 408 PA
0911 ANC 406 PA
0911 ANC 413 PBT
0911 ANC 415 PBT
Insert
0911 ANC 408 PA
0911 ANC 406 PA
0911 ANC 413 PBT
0911 ANC 415 PBT
Mechanical Data
Degree of protection
0911 ANC 408 IP 67
0911 ANC 413 IP 67 / IP 69K
Electrical 4 A
113www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface Accessories
0913 ATL 003 | 0913 ATL 002 | 0913 ATL 004
Description
0913 ATL 003
This AS-Interface Handheld controller serves to
address the AS-Interface sensors, actuators
and round cable modules. The mechanical
connection is made by a mating M12
connector. AS-Interface flat cable modules
are connected using the addressing adaptor
type 0913 ATL 002/0.35 M. With this
addressing equipment, all types of AS-
Interface modules (including equipment with
ASInterface Version 2.1) can be addressed.
0913 ATL 002
The addressing adaptor is able to address the
AS-Interface flat cable modules with existing
handheld addressing units, length 0.35 m
– suitable to addressing unit 0913 ATL 003.
Part Number
0913 ATL 003
0913 ATL 002/0.35M
114Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
AS-Interface Accessories
0911 ANC 409
Description
0911 ANC 409
Terminal sleeves for flat cable, packing unit:
10 pieces.
Part Number
0911 ANC 409
115www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
AS-Interface Accessories
ZBS | ZVK
Description
ZBS
Attachable labels, 10 pieces ( 7 x 14mm).
ZVK
Dust cover for unused M12 sockets.
Part Number
ZBS
ZVK
116Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link BusHead Profibus-Slave
0940 PSL 601
Description
LioN-Link BusHead IP 67 bus coupler module
for the connection between the higher level
fieldbus and the fieldbus independent I/O
modules, with M12 bus connection, rotary
switches for addressing, M12 LioN-Link
connection, M12 power supply connection.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Diagnostic Indication
Part Number
0940 PSL 601
LED Indication Condition
I/O Line 1, I/O Line 2 redgreenoff
wrong configuration / module exchangedonline, communication with PLCbranch not in use (module not connected)
US1 green sensor / system power supply Line 1
US2 green sensor / system power supply Line 2
BF red bus error
DIA red common inidcation for periphery faults
Bus Connection M12, B coded LioN-Link connection M12 Power supply M12
Pin Assignments
1 = Drain2 = 24 V System3 = 0 V System4 = Data +5 = Data -
1 = +24 V2 = +24 V3 = 0 V4 = 0 V5 = Earth
1 = +5 V 1
2 = Line A3 = GND (O V) 1
4 = Line B5 = Earth
1 = internal signals
117www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 200 g
Housing PBT
Bus System Profibus DP
ID number 0A36 hex
GSD file Lum_0A36.GSD
Transmission rate max. 12 MBaud
Address range 1—125 dec
Rotary address switches 1—99 dec
Default address 99 dec
System/Sensors
Power Supply US1, US2*
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption typ. 100 mA
Reverse polarity protection yes
Indication LED green
Output current per branch max. 3 A
Included in delivery / accessories
Dust covers M12, attachable labels
* Both supply points on the BusHead must always be connected.
Diagnostic
Diagnosis according to Profibus specification, diagnosis for communication status,
module breakdown and periphery faults in the Link system
Purpose
BusHead for LioN-Link standard modules
LioN-Link BusHead Profibus-Slave - 0940 PSL 601
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
118Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link BusHead Profibus-Slave
0940 PSL 602
Description
LioN-Link BusHead IP 67 bus coupler module
for the connection between the higher level
fieldbus and the fieldbus independent I/O
modules, with M12 bus connection, rotary
switches for addressing, M12 LioN-Link
connection, M12 power supply connection.
– Supports Profibus DP-V1
(acyclic communication)
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Diagnostic Indication
Part Number
0940 PSL 602
LED Indication Condition
I/O Line 1, I/O Line 2 redgreenoff
wrong configuration / module exchangedonline, communication with PLCbranch not in use (module not connected)
US1 green sensor / system power supply Line 1
US2 green sensor / system power supply Line 2
BF red bus error
DIA red common inidcation for periphery faults
Bus Connection M12, B coded LioN-Link connection M12 Power supply M12
Pin Assignments
1 = Drain2 = 24 V System3 = 0 V System4 = Data +5 = Data -
1 = +24 V2 = +24 V3 = 0 V4 = 0 V5 = Earth
1 = +5 V 1
2 = Line A3 = GND (O V) 1
4 = Line B5 = Earth
1 = internal signals
119www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 200 g
Housing PBT
Bus System Profibus DP
ID number 0B99 hex
GSD file Lum_0B99.GSD
Transmission rate max. 12 MBaud
Address range 1—125 dec
Rotary address switches 1—99 dec
Default address 99 dec
System/Sensors
Power Supply US1, US2*
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption typ. 100 mA
Reverse polarity protection yes
Indication LED green
Output current per branch max. 3 A
Included in delivery / accessories
Dust covers M12, attachable labels
* Both supply points on the BusHead must always be connected.
Diagnostic
Diagnosis according to Profibus specification, diagnosis for communication status,
module breakdown and periphery faults in the Link system
Purpose
BusHead for LioN-Link standard modules, Motion module “0942 UEM 783”
and I/O-Link module “0942 UEM 620”
LioN-Link BusHead Profibus-Slave - 0940 PSL 602
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
120Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link BusHead Profibus-Slave
0940 PSL 603
Description
LioN-Link BusHead IP 67 bus coupler module
for the connection between the higher level
fieldbus and the fieldbus independent I/O
modules, with M12 bus connection, rotary
switches for addressing, M12 LioN-Link
connection, M12 power supply connection.
– Profibus-Slave, for applications such as tool
change or options handling with LioN-Link
I/O module 0942 UEM 670
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Diagnostic Indication
Part Number
0940 PSL 603
LED Indication Condition
I/O Line 1, I/O Line 2 redgreenoff
wrong configuration / module exchangedonline, communication with PLCbranch not in use (module not connected)
US1 green sensor / system power supply Line 1
US2 green sensor / system power supply Line 2
BF red bus error
DIA red common inidcation for periphery faults
Bus Connection M12, B coded LioN-Link connection M12 Power supply M12
Pin Assignments
1 = Drain2 = 24 V System3 = 0 V System4 = Data +5 = Data -
1 = +24 V2 = +24 V3 = 0 V4 = 0 V5 = Earth
1 = +5 V 1
2 = Line A3 = GND (O V) 1
4 = Line B5 = Earth
1 = internal signals
121www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 200 g
Housing PBT
Bus System Profibus DP
ID number 0B98 hex
GSD file Lum_0B98.GSD
Transmission rate max. 12 MBaud
Address range 1—125 dec
Rotary address switches 1—99 dec
Default address 99 dec
System/Sensors
Power Supply US1, US2*
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption typ. 100 mA
Reverse polarity protection yes
Indication LED green
Output current per branch max. 3 A
Included in delivery / accessories
Dust covers M12, attachable labels
* Both supply points on the BusHead must always be connected.
Diagnostic
Diagnosis according to Profibus specification, diagnosis for communication status,
module breakdown and periphery faults in the Link system
Purpose
BusHead for LioN-Link standard modules, “shadow module 0942 UEM 670”
and “tool change mode”
LioN-Link BusHead Profibus-Slave - 0940 PSL 603
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
122Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link BusHead ProfiNet-I/O Device-Slave (ProfiNet LAN)
0940 ESL 601
Description
LioN-Link BusHead IP 67 bus coupler module
for the connection between the higher level
fieldbus and the fieldbus independent I/O
modules, with M12 LioN-Link connection,
M12 power supply connection.
– M12 LAN connection, D coded, integrated
3-port switch, web server, IRT (Isochrone
Real Time communication)
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Diagnostic Indication
Part Number
0940 ESL 601
LED Indication Condition
I/OS1 red wrong configuration / module exchanged
I/OS2 red wrong configuration / module exchanged
green online, communication with PLC
off branch not in use
US1 green sensor / system power supply Line 1
US2 green sensor / system power supply Line 2
LNK/ACT green connection to an Ethernet device
orange (flashing) I/O device exchanging data
green online, communication with BusHead
BF red no I/O controller or wrong LioN-Link configuration
DIA red common inidcation for periphery faults
LAN connection M12, D coded LioN-Link connection M12 Power supply M12
Pin Assignments
1 = Drain2 = 24 V Sensor / System3 = 0 V Sensor / System4 = Data +5 = Data -
1 = +24 V2 = +24 V3 = 0 V4 = 0 V5 = earth
1 = TD+2 = RD+3 = TD-4 = RD-Housing = Shield
123www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 800 g
Housing PBT
Bus System PROFINET IO
VendorID 0016A hex
DeviceID 0302 hex
GSDML file gsdml-v2.2-Lumberg Automation-LioN Link-20090623.xml
Transmission rate 100 Mbit/S full duplex
Transmission method 100Base-TX
Default IP address 0
System/Sensors
Power Supply US1, US2*
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption typ. 100 mA
Reverse polarity protection yes
Indication LED green
Output current per branch max. 3 A
Connection M12 plug insert (5 poles), see pin assignment
Included in delivery / accessories
Dust covers M12, attachable labels
* Both supply points on the BusHead must always be connected.
Purpose
BusHead for LioN-Link standard modules, Motion module “0942 UEM 783”
and I/O-Link module “0942 UEM 620”
LioN-Link BusHead ProfiNet-I/O Device-Slave (ProfiNet LAN) - 0940 ESL 601
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
124Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Modules with 8 Digital Inputs and Outputs
0942 UEM 600 (8 In / 8 Out)
Description
LioN-Link I/O module with 8 digital I/O
channels, channels can be used universally
as inputs or outputs, M12 sockets (4 x), 5
poles, M12 actuator supply.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0942 UEM 600
Bit 7 6 5 4 3 2 1 0
M12 Input
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
M12 Output
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
LED Indication Condition
1...4 A/B yellow channel status
1...8 A/B red periphery fault
I/O green sensor/system power supply
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
UL green actuator power supply
DIA red common inidcation for periphery faults
LioN-Link connection M12 Actuator / sensor connection M12 Actuator supply M12
Pin Assignments
1 = Drain2 = 24 V Sensor / System3 = 0 V Sensor / System4 = Data +5 = Data -
1 = +24 V2 = In / Out B3 = 0 V4 = In / Out A5 = earth
1 = +24 V2 = n.c.3 = GND (0 V)4 = n.c.5 = earth
125www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 200 g
Housing PBT
System/Sensors
Power Supply US
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption typ. 70 mA
Operating indication LED green
Input Power Supply US
Voltage range min. (USystem - 1.5 V)
Sensor current 700 mA / module
Short circuit-proof yes
Indication LED, green
Input Wiring Type 3 Acc. to
IEC 61131-2
Rated input voltage 24 V DC
Channel type N.O. p-switching
Number of digital channels max. 8
Channel status indicator LED, yellow per channel
Diagnosis Indicator LED, red per channel
Output Power Supply UL
Rated voltage 24 V DC
Voltage range 19-30 V DC
Reverse polarity protection yes / antiparallel diode
Indication LED, green
Output Wiring
Rated output current 1.6 A per channel
Short circuit proof yes
Max. Output current 4 A per module
Overload proof yes
Number of digital channels max. 8
Channel type N.O. p-switching
Channel status indicator LED, yellow per channel
Diagnostic indication LED red per channel
Included in delivery / accessories
Dust covers M12, attachable labels
Diagnostic
Periphery fault diagnosis for sensor short circuit,
actuator short circuit /channel, sensor low
voltage detection.
LioN-Link I/O Modules - 0942 UEM 600 (8 In / 8 Out Universal)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
126Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Modules with 8 Digital Inputs
0942 UEM 601 (8 In)
Description
LioN-Link I/O module with 8 digital inputs
to connect standard sensors, M12 sockets (4 x),
5 poles.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0942 UEM 601
Bit 7 6 5 4 3 2 1 0
M12 Input
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
LED Indication Condition
1...4 A/B yellow channel status
1...4 A red periphery fault
I/O green sensor/system power supply
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
DIA red common inidcation for periphery faults
LioN-Link connection M12 Actuator / sensor connection M12
Pin Assignments
1 = Drain2 = 24 V Sensor / System3 = 0 V Sensor / System4 = Data +5 = Data -
1 = +24 V2 = In B3 = GND (0 V)4 = In A5 = earth
127www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 175 g
Housing PBT
System/Sensors
Power Supply US
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption typ. 70 mA
Operating indication LED green
Input Power Supply US
Voltage range min. (USystem - 1.5 V)
Sensor current 700 mA / module
Short circuit-proof yes
Indication LED, green
Input Wiring Type 3 Acc. to
IEC 61131-2
Rated input voltage 24 V DC
Channel type N.O. p-switching
Number of digital channels max. 8
Channel status indicator LED, yellow per channel
Diagnosis Indicator LED, red per channel
Diagnostic
Periphery fault diagnosis for sensor short circuit, actuator short circuit /channel, sensor low voltage detection.
Included in delivery / accessories
Dust covers M12, attachable labels
LioN-Link I/O Modules - 0942 UEM 601 (8 In)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
128Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Modules with 4 Digital Outputs
0942 UEM 602 (4 Out)
Description
LioN-Link I/O module with 4 digital outputs,
M12 sockets (4 x), 5 poles, 2 A per channel,
one channel per socket.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0942 UEM 602
Bit 7 6 5 4 3 2 1 0
M12 Output
Byte 0 - - - - 4A 3A 2A 1A
LED Indication Condition
1...4 A yellow channel status
1...4 DIA red periphery fault /output active with noactuator supply voltage
I/O red wrong configuration /module exchanged
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
UL green actuator power supply
DIA red common inidcation for periphery faultsPin Assignments
LioN-Link connection M12 Actuator connection M12 Actuator supply M12
1 = Drain2 = 24 V Sensor / System3 = 0 V Sensor / System4 = Data +5 = Data -
1 = n.c.2 = n.c.3 = 0 V4 = Out A5 = earth
1 = +24 V DC2 = +24 V DC3 = GND (0 V)4 = GND (0 V)5 = functional earth
129www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 200 g
Housing PBT
System/Sensors
Power Supply US
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption typ. 70 mA
Output Power Supply US
Rated voltage 24 V DC
Voltage range 19–30 V DC
Reverse polarity protection yes/antiparallel diode
Indication LED green
Connection M12 connector (3 or 5 poles)
Output Wiring
Rated output current 2.0 A per channel
Short circuit proof yes
Max. output current 4 A (3 pole supply line); 6 A (5 pole supply line)
Number of digital channels max. 4
Channel type N.O. p-switching
Channel status indicator LED yellow per channel
Diagnostic indication LED red per channel
Included in delivery / accessories
Dust covers M12, attachable labels
Diagnostic
Periphery fault diagnosis for actuator short circuit /overload per channel.
Note
Particularly suitable for the control of hydraulic valves.
LioN-Link I/O Modules - 0942 UEM 602 (4 Out)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
130Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Modules with 4 Digital Outputs
0942 UEM 612 (4 Out)
Description
LioN-Link I/O module with 4 digital outputs,
M12 sockets (4 x), 5 poles, M12 actuator
supply, 2 A per channel, one channel per
socket
– Suitable for safety critical applications
within Performance Levels A through D.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0942 UEM 612
Bit 7 6 5 4 3 2 1 0
M12 Output
Byte 0 - - - - 4B 3A 2A 1A
LED Indication Condition
1...4 A yellow channel status
1...4 DIA red periphery fault /output active with no actuator supply voltage
I/O red wrong configuration /module exchanged
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
UL green actuator power supply
DIA red common inidcation for periphery faults
Pin Assignments
LioN-Link connection M12 Actuator connection M12 Actuator supply M12
1 = Drain2 = 24 V Sensor / System3 = 0 V Sensor / System4 = Data +5 = Data -
1 = n.c.2 = n.c.3 = 0 V4 = Out A5 = earth
1 = +24 V DC2 = +24 V DC3 = GND (0 V)4 = GND (0 V)5 = functional earth
131www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 200 g
Housing PBT
System/Sensors
Power Supply US
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption typ. 70 mA
Operating indication LED green
Output Power Supply UL
Rated voltage 24 V DC
Voltage range 19–28.8 V DC (SELV/PELV acc. to EN60950-1)
Reverse polarity protection yes/antiparallel diode, external fuse with 4/6 A medium time lag mandatory
Indication LED green
Connection M12 connector (3 or 5 poles)
Output wiring
Rated output current 2.0 A per channel
Short circuit proof yes
Max. output current 4 A (3 pole supply line); 6 A (5 pole supply line)
Overload proof yes
Number of digital channels max. 4
Channel type N.O. p-switching
Channel status indicator LED yellow per channel
Diagnostic indication LED red per channel
Included in delivery / accessories
Dust covers M12, attachable labels
Diagnostic
Periphery fault diagnosis for actuator short circuit/overload per channel.
Note
Due to the need to guarantee reliable, all pole disconnection of the output voltage supply on the customer
side, utilization in emergency power off circuits is possible for applications up to Performance Level D. The
absence of reaction between the logic and output supply circuits in the event of a hardware fault in the
module is guaranteed. The instructions in the LioN-Link manual must be observed in this case.
LioN-Link I/O Modules - 0942 UEM 612 (4 Out)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
132Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Module with 8 Digital Inputs and 4 I/O-Link Inputs(I/O-Link-Master)
0942 UEM 620 (8 In / 4 I/O -Link IN universal)
Description
LioN-Link I/O module with 4 I/O-Link
channels, each channel can be configured
universally in standard digital I/O mode
(SIO mode) or in communications mode,
M12 sockets, 4 poles
– Only with BusHead 0940 PSL 602
or ProfiNet BusHead 0940 ESL 601
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Diagnostic Indication
Part Number
0942 UEM 620
LED Indication Condition
1...4 A | IOL: green I/O-Link communications mode
yellow standard I/O mode (SIO)
1...4 B | DIA: red flashing I/O-Link diagnostic: IOL fault
red SIO mode: periphery fault
I/O yellow channel status in SIO mode
red wrong configuration / module exchanged
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
UL green I/O-Link supplyDIA red common inidcation for periphery faults
Pin Assignments
LioN-Link connection M12 I/O-Link connection M12 I/O-Link supply M12
1 = Drain2 = 24 V Sensor / System3 = 0 V Sensor / System4 = Data +5 = Data -
1 = +24 V2 = In B3 = (0 V)4 = I/O-Data / In A5 = earth
1 = +24 V2 = n.c.3 = GND (0 V)4 = n.c.5 = functional earth
133www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 175 g
Housing PBT
System/Sensors
Power Supply US
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption typ. 70 mA
Operating indication LED green
Input Power Supply US
Voltage range 24 V DC
Sensor current 700 mA/module
Short circuit proof yes
Indication LED green
Input Wiring Type 3 Acc. to IEC 61131-2
Rated input voltage 24 V DC
Channel type N.O. p-switching
Number of digital channels max. 8
Channel status indicator LED A green/yellow
Diagnosis Indicator LED, red
I/O-Link power supply UL
Rated voltage 24 V DC
Voltage range 19–30 V DC
Reverse polarity protection yes/antiparallel diode
Indication LED green
I/O-Link Specification 1.0
Included in delivery / accessories
Dust covers M12, attachable labels
Note
The information in the operating instructions must be observed
LioN-Link I/O Modules - 0942 UEM 620 (4 In / 4 I/O -Link IN universal)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
Channel: 1 byte, 1 word or not configured
Byte Byte 0 Byte 1
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Port 1 1
Channel: 2 byte, 1 word or not configured
Byte Byte 2 Byte 3
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Port 2 2
Assignment I/O-Link-Device process data/High Byte I/O-Link-Device process data/Low Byte
Channel: 3 byte, 1 word or not configured
Byte Byte 4 Byte 5
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Port 3 3
Assignment I/O-Link-Device process data/High Byte I/O-Link-Device process data/Low Byte
Channel: 4 byte, 1 word or not configured
Byte Byte 6 Byte 7
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Port 4 4
Assignment I/O-Link-Device process data/High Byte I/O-Link-Device process data/Low Byte
2 Bytes (module status)
Byte Byte 8 Byte 9
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Port 4 3 2 1 4 3 2 1 4 3 2 1
Assignment Pin 4 = DI Pin 4 = DI Pin 4 = DI Pin 4 = DI1=IO-Link
O-SIO1=IO-Link
O-SIO1=IO-Link
O-SIO1=IO-Link
O-SIOPin 2 = DI Pin 2 = DI Pin 2 = DI Pin 2 = DI
Bit Assignments
134Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Modules with 4 Analog Inputs
0942 UEM 630
Description
LioN-Link I/O module with 4 analog inputs
0(4)–20 mA to connect standard sensors,
M12 sockets (4x), 5 poles.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0942 UEM 630
Bit 7 6 5 4 3 2 1 0
M12 Input
Byte 0Channel 1
Byte 1
Byte 2Channel 2
Byte 3
Byte 4Channel 3
Byte 5
Byte 6Channel 4
Byte 7
LED Indication Condition
1...4 yellow channel status
1...4 DIA red periphery fault
I/O green sensor/system power supply
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
DIA red common inidcation for periphery faults
LioN-Link connection M12 Sensor connection M12
Pin Assignments
1 = Drain2 = +24 V3 = GND (0 V)4 = Data +5 = Data -
1 = +24 V2 = Signal +3 = GND (0 V)4 = GND (0 V)5 = earth
135www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 175 g
Housing PBT
Input power supply US
Voltage range 24 V DC
Sensor current 700 mA/module
Short circuit proof yes
Power consumption system: typ. 50 mA
Input wiring Current inputs
Measurement signal (0)4–20 mA
Resolution 12 bit + sign
Measuring fault (full measuring range) ±1.2%
Temperature fault (full measuring range) ±0.01%/K
Output formats Siemens S7
Input impedance ≤400 Ω
Conversion time typ. 25 ms per channel
Potential separation
channel/channel no
Potential separation
power/channel no
Number of analog channels max. 4
Channel status indicator LED yellow: channel active
Module diagnostic Module status Sensor short circuit
Indication LED red/green (I/O)
Channel diagnostic
0–20 mA Overload at current measurement
4–20 mA Overload at current measurement/Underflow/Broken wire
Indication LED red (DIA)
GSD configuration
Module way Resolution 12 bit, 10 bit (Conversion time ≤3 ms/module)
Channel way Measuring range 0–20 mA or 4–20 mA
Broken wire (only 4–20 mA), Channel on/off, Diagnostic on /off
Included in
delivery/accessories Dust covers M12, attachable labels
LioN-Link I/O Modules - 0942 UEM 630 (4 In - Analog)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
136Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Modules with 4 Analog Inputs
0942 UEM 631
Description
LioN-Link I/O module with 4 analog
inputs 0–10 V to connect standard sensors,
M12 sockets (4x), 5 poles.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0942 UEM 631
Bit 7 6 5 4 3 2 1 0
M12 Input
Byte 0Channel 1
Byte 1
Byte 2Channel 2
Byte 3
Byte 4Channel 3
Byte 5
Byte 6Channel 4
Byte 7
LED Indication Condition
1...4 yellow channel status
1...4 DIA red periphery fault
I/O green sensor/system power supply
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
DIA red common inidcation for periphery faults
LioN-Link connection M12 Sensor connection M12
Pin Assignments
1 = Drain2 = +24 V3 = GND (0 V)4 = Data +5 = Data -
1 = +24 V2 = Signal +3 = GND (0 V)4 = GND (0 V)5 = earth
137www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 175 g
Housing PBT
Input power supply US
Voltage range 24 V DC
Sensor current 700 mA/module
Short circuit proof yes
Power consumption system: typ. 50 mA
Input wiring Voltage inputs
Measurement signal 0-10 V
Resolution 12 bit + sign
Measuring fault (full measuring range) ±1.2%
Temperature fault (full measuring range) ±0.01%/K
Output formats Siemens S7
Input impedance 20 kΩ
Conversion time typ. 25 ms per channel
Potential separation
channel/channel no
Potential separation
power/channel no
Number of analog channels max. 4
Channel status indicator LED yellow: channel active
Module diagnostic Module status Sensor short circuit
Indication LED red/green (I/O)
Channel diagnostic Overflow
Indication LED red (DIA)
GSD configuration
Module way Resolution 12 bit, 10 bit (Conversion time ≤3 ms/module)
Channel way Channel on/off, Diagnostic on /off
Included in
delivery/accessories Dust covers M12, attachable labels
LioN-Link I/O Modules - 0942 UEM 631 (4 In - Analog)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
138Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Modules with 8 Digital Inputs and Outputs (Shadow Mode)
0942 UEM 670 (8 In/8 Out universal)
Description
LioN-Link I/ O module with 8 digital I/O
channels, channels can be used universally
as inputs or outputs, M8 sockets, 3 poles
Input or output functionality can be switched
off while retaining the respective address
range*.
* = Only with 0940 PSL 603. DC
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0942 UEM 670
Bit 7 6 5 4 3 2 1 0
M8 Input
Byte 0 8 7 6 5 4 3 2 1
M8 Output
Byte 0 8 7 6 5 4 3 2 1
LED Indication Condition
1...8 yellow channel status
1...8 red periphery faults (actuator short circuit/overload)
I/O red wrong configuration /module exchanged
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
UL green actuator power supply
DIA red common inidcation for periphery faults
Pin Assignments
LioN-Link connection M12 Actuator/sensor connection M8 Actuator supply M12
1 = Drain2 = 24 V Sensor / System3 = 0 V Sensor / System4 = Data +5 = Data -
1 = +24 V2 = 0 V3 = In/Out
1 = +24 V2 = n.c.3 = GND (0 V)4 = n.c.5 = functional earth
139www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
LioN-Link I/O Modules - 0942 UEM 670 (8 In/8 Out universal)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 175 g
Housing PBT
System/Sensors
Power Supply US
Rated voltage 24 V DC
Voltage range 19-30 V DC
Power consumption typ. 70 mA
Operating indication LED green
Input Power Supply US
Voltage range 24 V DC
Sensor current 700 mA / module
Short circuit-proof yes
Indication LED, green
Input Wiring Type 3 Acc. to
IEC 61131-2
Rated input voltage 24 V DC
Channel type N.O. p-switching
Number of digital channels max. 8
Channel status indicator LED, yellow per channel
Diagnosis Indicator LED, red per channel
Output Power Supply UL
Rated voltage 24 V DC
Voltage range 19-30 V DC
Reverse polarity protection yes / antiparallel diode
Indication LED, green
Output Wiring
Rated output current 0.5 A per channel
Short circuit proof yes
Max. Output current 4 A per module
Overload proof yes
Number of digital channels max. 8
Channel type N.O. p-switching
Channel status indicator LED, yellow per channel
Diagnostic indication LED red per channel
Included in delivery / accessories
Dust covers M12, attachable labels
Diagnostic
Periphery fault diagnosis for sensor short circuit,
actuator short circuit, sensor low voltage detection.
Note
This I/O module can only be used with the BusHead
0940 PSL 603
In addition to being used as a dedicated input or
output module, this module can also be operated in
Shadow Input and Shadow Output mode.
The process data in both modes is 1 input and 1
output byte. In Shadow Input mode the input byte is
set to 0. The outputs can be activated via the output
byte. In Shadow Output mode, however, the outputs
cannot be activated and the inputs can be used
normally.
140Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Module with 16 Digital Inputs and Outputs
0942 UEM 700 (16 IN / 16 OUT universal)
Description
LioN-Link I/O module with 16 digital I/O
channels, channels can be used universally
as inputs or outputs, M12 sockets (8 x),
5 poles, 7/8” actuator supply.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0942 UEM 700
Bit 7 6 5 4 3 2 1 0
M12 Input
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
Byte 1 8B 8A 7B 7A 6B 6A 5B 5A
M12 Output
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
Byte 1 8B 8A 7B 7A 6B 6A 5B 5A
LED Indication Condition
1...8 A/B yellow channel status
1...8 red periphery faults (actuator short circuit/overload)
I/O red wrong configuration /module exchanged
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
UL green actuator power supply
DIA red common inidcation for periphery faults
Pin Assignments
LioN-Link connection M12 Actuator/sensor connection M12 Actuator supply 7/8”
1 = Drain2 = 24 V Sensor / System3 = 0 V Sensor / System4 = Data +5 = Data -
1 = +24 V2 = In/Out B3 = 0 V4 = In/Out A5 = earth
1 = GND (0 V)2 = GND (O V)3 = earth4 = 24 V (UL 1-4)
5 = 24 V (UL 5-8)
141www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 375 g
Housing PBT
System/sensors
power supply US
Rated voltage 24 V DC
Voltage range 19–30 V DC
Power consumption typ. 100 mA
Input power supply US
Voltage range min. (USystem – 1.5 V)
Sensor current 700 mA
Short circuit proof yes
Indication LED green
Input wiring Type 3 acc. to IEC 61131-2
Rated input voltage 24 V DC
Channel type N.O. p-switching
Number of digital channels max. 16
Channel status indicator LED yellow per channel
Output power supply UL
Rated voltage 24 V DC
Voltage range 19–30 V DC
Reverse polarity protection yes/antiparallel diode
Indication LED green
Output wiring
Rated output current 1.6 A per channel
Short circuit proof yes
Max. output current 9 A (12 A*) per module
* Test proven and approved under the following conditions:
· Looped through sensor / system power supply max. 2.5 A
· Power supply cable STL 204 (5 x1.00 mm2)
· Operating temperature range max. 40°C
Overload proof yes
Number of digital channels max. 16
Channel type N.O. p-switching
Channel status indicator LED yellow per channel
Diagnostic indication LED red per channel
Diagnostic
Periphery fault diagnosis for sensor short circuit, actuator short circuit, sensor low voltage detection
LioN-Link I/O Modules - 0942 UEM 700 (16 In / 16 Out universal)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
142Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Module with 16 Digital Inputs
0942 UEM 701 (16 IN)
Description
LioN-Link I/O module with 16 digital
inputs to connect standard sensors,
M12 sockets (8 x), 5 poles.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0942 UEM 701
Bit 7 6 5 4 3 2 1 0
M12 Input
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
Byte 1 8B 8A 7B 7A 6B 6A 5B 5A
LED Indication Condition
1...8 A/B yellow channel status
1...8 A red periphery faults (actuator short circuit/overload)
I/O red wrong configuration /module exchanged
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
DIA red common inidcation for periphery faults
Pin Assignments
LioN-Link connection M12 Actuator/sensor connection M12
1 = Drain2 = 24 V Sensor / System3 = 0 V Sensor / System4 = Data +5 = Data -
1 = +24 V2 = In/Out B3 = 0 V4 = In/Out A5 = earth
143www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 275 g
Housing PBT
System/sensors
power supply US
Rated voltage 24 V DC
Voltage range 19–30 V DC
Power consumption typ. 100 mA
Input power supply US
Voltage range min. (USystem – 1.5 V)
Sensor current 700 mA
Short circuit proof yes
Indication LED green
Input wiring Type 3 acc. to IEC 61131-2
Rated input voltage 24 V DC
Channel type N.O. p-switching
Number of digital channels max. 16
Channel status indicator LED yellow per channel
Diagnostic
Periphery fault diagnosis for sensor short circuit, actuator short circuit, sensor low voltage detection.
LioN-Link I/O Modules - 0942 UEM 701 (16 In)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
144Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Module with 16 Digital Outputs
0942 UEM 782 (16 Out)
Description
LioN-Link I/O module with 16 digital outputs,
multipole cable interface to connect valve
terminals, manual tool changing devices,
IP20 terminal boxes.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0942 UEM 782
LED Indication Condition
I/O red wrong configuration /module exchanged
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
UL green actuator power supply
DIA red common inidcation for periphery faults
Pin Assignments
Bit 7 6 5 4 3 2 1 0
M12 Output
Byte 0 RD BU PK GY YE GN BN WH
Byte 1 YE/BN WH/YE BN/GN WH/GN RD/BU GY/PK VT BK
LioN-Link connection M12 Actuator / sensor connection M12
1 = Drain2 = 24 V Sensor / System3 = 0 V Sensor / System4 = Data +5 = Data -
1 = +24 V (UL 1-8)2 = +24 V (UL 9-16)3 = GND (0 V)4 = GND (0 V)5 = earth
145www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
LioN-Link I/O Modules - 0942 UEM 782 (16 Out)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 320 g (with 1m cable)
Housing PBT
System/sensors
power supply US
Rated voltage 24 V DC
Voltage range 19–30 V DC
Power consumption 40 mA
Output power supply UL
Rated voltage 24 V DC
Voltage range 19–30 V DC
Reverse polarity protection yes/antiparallel diode
Indication LED green
Output wiring
Rated output current 0.5 A per channel
Short circuit proof yes
Max. output current 6 A (3 A per group)
Group 1 Channel 1–8
Group 2 Channel 9-16
Overload proof yes
Number of digital channels max. 16
Channel type N.O. p-switching
Diagnostic
Periphery fault diagnosis for actuator short circuit.
146Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LioN-Link I/O Module with 8 Digital Inputs and 4 Digital or Analog Outputs (Motion Drive Control)
0942 UEM 783 (8 In / 4 Out - Digital or Analog)
Description
LioN-Link Motion module with 8 digital
inputs and 4 universal outputs that can be
configured for the connection of brushless
motors, DC motors or for valves. System
specific specifications such as speed and
acceleration/deceleration can be transmitted
via the DP-V1* protocol. Power supply is via
a connecting cable with 7/8” connector.
* = Only with 0940 PSL 602
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Bit Assignments Diagnostic Indication
Part Number
0942 UEM 783
LED Indication Condition
1...4 A/B yellow channel status
1...4 A/B red periphery faults (actuator short circuit/overload)
I/O red wrong configuration /module exchanged
red flashing not recognized by the BusHead
green online, communication with BusHead
US green sensor / system power supply
UL green actuator power supply
DIA red common inidcation for periphery faults
Pin Assignments
Bit 7 6 5 4 3 2 1 0
M12 Input
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
M12 Output
Socket 8 Socket 7 Socket 6 Socket 5
Byte 0 Dir Start Dir Start Dir Start Dir Start
LioN-Link connection M12 Actuator / sensor connection M12 Power supply for motors
1 = Drain2 = 24 V Sensor / System3 = 0 V Sensor / System4 = Data +5 = Data -
In1 = +24 V DC2 = In B3 = 0 V4 = In A5 = earth
Out1 = +24 V DC2 = Dir3 = 0 V4 = Dia5 = Speed (0-10 V)
Function1 = Diag. Out2 = + 24 V3 = 0 V
Wire ColorBlackBrownBlue
147www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Degree of protection IP 67
Temperature range -10°C / +60°C
Weight 175 g
Housing PBT
System/sensors
power supply US
Rated voltage 24 V DC
Voltage range 1 9–30 V DC
Power consumption typ. 100 mA
Reverse polarity protection no
Operating indication LED green
Input power supply US
Voltage range 24 V DC
Sensor current 700 mA/module
Short circuit proof yes
Indication LED green
Connection M12 connector (5 poles),
see pin assignment
Module diagnostic Module status Sensor short circuit
Indication LED red/green (I/O)
Input wiring Type 3 acc. to IEC 61131-2
Rated input voltage 24 V DC
Input current at 24 V DC typ. 5 mA
Short circuit proof
sensor supply yes
Channel type N.O. p-switching
Number of digital channels max. 8
Channel status indicator LED yellow per channel
Diagnostic indication LED red per channel
Connection M12 coupling (5 poles),
see pin assignment
Output power supply UL
Rated voltage 24 V DC
Voltage range 19–27 V DC
Reverse polarity protection yes/antiparallel diode
Indication LED green
Connection 7/8” connector (3 poles), see pin
assignment
Output wiring I Type 3 acc. to IEC 61131-2
Output module Pin 2
Rated output current 1.5 A per channel
Signal status “1” max. 4 A (max. 50 ms)
Signal status “0” max. 1 mA (standard specification)
Short circuit proof y es
Max. output current 7.2 A per module
Overload proof yes
Number of digital channels max. 4
Channel type N.O. p-switching
Channel status indicator LED yellow per channel
Diagnostic indication LED red per channel
Connection M12 coupling (5 poles),
see pin assignment
Output wiring II Output module Pin 5
Voltage range 0–10 V DC (motor dependent)
Number of channels max. 4 analog
Channel type PWM output
Connection M12 coupling (5 poles),
see pin assignment
Included in
delivery/accessories Dust covers M12, attachable labels
Diagnostic
Periphery fault diagnosis for sensor short circuit, actuator short
circuit /channel, sensor low voltage detection
Note
Only to be used in combination with BusHead 0940 PSL 602.
Module used to control brushless (EC) motors as well as brush
loaded (DC) motors and all types of digital actuators
(e.g. valves or direct current motors)
LioN-Link I/O Modules - 0942 UEM 783 (Motion Drive Control)
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
148Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Power Distributor with 4 M12 Sockets
0941 UNC 601
Description
LioN-Link power distributor,
4x M12 ports, 2 potential circuits,
10 m lead with 5x1 mm2
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Part Number
0941 UNC 601
Power supply 1A- &2A-M12 1B- & 2B-M12 Cable assignment
Pin Assignments
1 = 24 V ULA
2 = n.c.3 = GND 0 V ULA
4 = n.c.5 = earth
1 = 24 V ULB
2 = n.c.3 = GND 0 V ULB
4 = n.c.5 = earth
Function
+24 V ULA
+24 V ULB
GND 0 V ULA
GND 0 V ULB
earth
Wire Color
black 1black 2black 3black 4green/yellow
149www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Technical Data
Material
Housing PBT
Contact holder PA
Contact M12 CuSn, pre-nickeled and 0.3 μm gold plated
Threaded bush CuSn, nickel plated
O-ring FKM
Operating Temperature
Range -25°C / +70°C
Mechanical Data
Degree of protection IP 67
Only in the locked or bolted state with the
corresponding counterparts or dust covers
Electrical Data Type 3 acc. to IEC 61131-2
Rated current at 40°C 4 A/port, 12 A.module
Rated voltage 10-30 V
Operating indication LED green
Insulation resistance >109 Ω
Degree of contamination 3
Included in delivery / accessories
Dust covers M12, attachable labels
Power Distributor with 4 M12 Sockets - 0941 UNC 601
The application of these products in harsh environments should always be checked before use.
Specifications subject to alteration.
150Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Industrial Ethernet Switches for ProfiNet and Ethernet/IP
0982 EEC 100
Description
Ethernet-Switch, IP 67, 5-port switch for 10
and 100 Mbaud transmission rates, M12 socket
4 poles D coding, M12 power supply 5 poles
standard coding.
Part Number
0982 EEC 100
M12 Socket Power Supply M12
Pin
Assignments
1 = TD+2 = RD+3 = TD-4 = RD-5 = shield
1 = 24 V2 = n.c3 = GND (0 V)4 = n.c.5 = earth
Technical Data
Degree of protection IP 67Operating temperature 0°C / +60°CWeight 210 gHousing material PUR
Switch FunctionalityMode of operation Store and forwardNumber of storable addresses 1000Aging time 300 sTagging EtherNet telegrams with VLAN tag field are transmitted unchanged
Ethernet Ports 10BASE-T / 100BASE-TXData transmission rate 10 Mbit/s and 100 Mbit/sCable type Twisted Pair (TP/TX) or star quad, CAT 5, shieldedNumber of ports 5Length of a TP segment 100 mLink control yesAutopolarity yesAutonegotiation yesAutocrossing yesChannel status indicator LED green per port
Electronics Power Supply PWRRated voltage 24 V DCVoltage range 18–30 V DCPower consumption 2.4 WReverse polarity protection yesIndication LED green
Included in Delivery / Accessories Dust covers M12 2 piecesAttachable labels 10 pieces
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
151www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Industrial Ethernet Panel-Mount Adaptors for ProfiNet and Ethernet/IP
0981 ENC 100
Description
RJ45/M12 adaptor, female receptacle
connector M12, D coding, chassis side thread
PG 9, RJ45 female connector, 90 degree.
Part Number
0981 ENC 100
M12 RJ45 Socket
1 = TD+2 = RD+3 = TD-4 = RD-
1 = TD+2 = TD-3 = RD+4 = n.c.
Technical Data
Operating Temperature Range 0°C / +70°C
MaterialsHousing PAM12 contacts CuZn, pre-nickeled and gold-platedM12 housing CuZn, nickel-platedM12 insert PUR, self- extinguishingM12 O-ring FKMRJ-45 contacts CuSn, pre-nickeled and gold-platedRJ-45 housing CuZn, tin-platedRJ-45 insert PA GF
Electrical DataNominal current 1.5 ANominal voltage max. 60 V
5 = n.c.6 = RD-7 = n.c.8 = n.c.
Pin Assignments
152Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Industrial Ethernet Double-Ended Cordsets for ProfiNet
0985 342 100
Description
Industrial Ethernet data cable according to
Profinet type C molded on both sides with
M12 male connector, D coding.
Part Number
0985 342 100/1M
0985 342 100/2M
0985 342 100/3M
0985 342 100/5M
M12 Socket
Pin
Assignments
1 = TD+2 = RD+3 = TD-4 = RD-
153www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Industrial Ethernet Double-Ended Cordsets for Ethernet/IP
0985 656 500 (Hi-Flex, Shielded, PVC)
Description
EtherNet/IP, Hi-flex, double-ended cordset,
male to male straight, 8-pin, 24 AWG PVC
cable, type 4 shielded, 4 twisted pair with teal
jacket.
Part Number
0985 656 500/0.5M
0985 656 500/1M
0985 656 500/2M
0985 656 500/5M
0985 656 500/10M
RJ45 Wiring Diagram
Technical Data
MaterialsHousing Pre-Tinned Copper alloyInsert Clear polycarbonateContacts 50 μ” gold in contact, area over nickel platingCover Elastomer polyolefin
Cable SpecificationsCable jacket PVC, (sun and oil resistant)Color TealOverall diameter 7.8mm, nominalConductor 24AWG, 7 strands of 32 AWG tinned copperInsulation PolyethyleneInner jacket PVCFoil shield Aluminum/Polypropylene/ Aluminmum Tape, 100% coverage Braided shield Tinned copper, 65% coverageEMI protection 50 dB @ 0.772 MHz - 1000 MHzAgency approval ETL rated CMR
MechanicalTemperature -20°C to 75°C
Pin Assignments
154Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Industrial Ethernet Double-Ended Cordsets for Ethernet/IP
0985 706 103 (Hi-Flex, Unshielded, TPE)
Description
EtherNet/IP, Hi-flex double-ended cordset,
M12 male straight, 4-pin D-coding to RJ45
male straight, 24 AWG TPE cable, stranded,
unshielded, 2 twisted pair with teal jacket.
Part Number
0985 706 103/0.5M
0985 706 103/1M
0985 706 103/2M
0985 706 103/5M
0985 706 103/10M
Technical Data
MaterialsMolded body M12 PUR, blackCoupling nut Brass, nickel platedContacts Brass, gold over nickel platedInsert PUR, blackRJ-45 Plug PolycarbonateRJ-45 Contacts Phosphor bronze, gold platedRJ-45 Boot Elastomer polyolefin
ElectricalCurrent rating 1.5 AVoltage rating 30 V AC / 42 V DCPerformance CAT5e
MechanicalTemperature -25°C to 60°CProtection IP 68, NEMA 6P (M12 end only)
Cable SpecificationsCable jacket FRTPEOverall diameter 5.3mm (.210”)Conductor 24 AWG stranded tinned copperTemperature MaxDry 105°CWet 75°COil 60°CTemperature Min -50°C
M12 (D-Coding) RJ45 Wiring Diagram
Pin Assignments
155www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Industrial Ethernet Double-Ended Cordsets for Ethernet/IP
0985 706 104 (Hi-Flex, Unshielded, TPE)
Description
EtherNet/IP, Hi-flex double-ended cordset,
M12 female straight receptacle, 4-pin
D-coding to RJ45 male straight, 24 AWG TPE
cable, stranded, unshielded, 2 twisted pair with
teal jacket.
Part Number
0985 706 104/0.5M
0985 706 104/1M
0985 706 104/2M
0985 706 104/5M
0985 706 104/10M
Technical Data
MaterialsM12 Housing Brass, nickel platedM12 Insert PUR, blackM12 Contacts Brass, gold platedRJ45 Plug PolycarbonateRJ45 Contacts Phosphor bronze, gold platedRJ45 Boot Elastomer polyolefin
ElectricalCurrent rating 1.5 AVoltage rating 30 V AC / 42 V DCPerformance CAT5e
Molded body M12 PUR, blackCoupling nut Brass, nickel platedContacts Brass, gold over nickel platedInsert PUR, self extinguishingMolded body RJ45 PUR, blackRJ-45 Insert Clear polycarbonateRJ-45 Contacts 50 μ” gold in contact, area over nickel plating
MechanicalTemperature -25°C to 60°CProtection IP 68, NEMA 6P (M12 end only)
Cable SpecificationsCable jacket FRTPEOverall diameter 5.3mm (.210”)Conductor 24 AWG stranded tinned copperTemperature MaxDry 105°CWet 75°COil 60°CTemperature Min -50°C
M12 (D-Coding) RJ45 Wiring Diagram Recommended Panel Cut Out
Pin Assignments
156Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Industrial Ethernet Double-Ended Cordsets for Ethernet/IP
0985 706 100 (Hi-Flex, Unshielded, TPE)
Description
EtherNet/IP, Hi-flex double-ended cordset,
M12 male to male straight, 4-pin, D-coding, 24
AWG TPE cable, stranded, unshielded, 2 twisted
pair with teal jacket.
Part Number
0985 706 100/0.5M
0985 706 100/1M
0985 706 100/2M
0985 706 100/5M
0985 706 100/10M
M12 (D-Coding)
Pin Assignments
Technical Data
MaterialsMolded body PUR, blackCoupling nut Brass, nickel platedContacts Brass, gold platedInsert PUR, black
ElectricalCurrent rating 4 AVoltage rating 250 VPerformance CAT5e
MechanicalTemperature -40°C to 90°CProtection IP 68, NEMA 6P
Cable SpecificationsCable jacket FRTPEOverall diameter 5.3mm (.210”)Conductor 24 AWG stranded tinned copperTemperature MaxDry 105°CWet 75°COil 60°CTemperature Min -50°C
1 = white/orange2 = white/green3 = orange4 = green
157www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Industrial Ethernet Double-Ended Cordsets for Ethernet/IP
0985 706 101 (Hi-Flex, Unshielded, TPE - Crossover)
Description
EtherNet/IP, Hi-flex double-ended crossover
cordset, M12 male to male straight, 4-pin,
D-coding, 24 AWG TPE cable, stranded,
unshielded, 2 twisted pair with teal jacket.
Part Number
0985 706 101/0.5M
0985 706 101/1M
0985 706 101/2M
0985 706 101/5M
0985 706 101/10M
M12 (D-Coding) Wiring Diagram
Pin Assignments
Technical Data
MaterialsMolded body PUR, blackCoupling nut Brass, nickel platedContacts Brass, gold platedInsert PUR, black
ElectricalCurrent rating 4 AVoltage rating 250 VPerformance CAT5e
MechanicalTemperature -40°C to 90°CProtection IP 68, NEMA 6P
Cable SpecificationsCable jacket FRTPEOverall diameter 5.3mm (.210”)Conductor 24 AWG stranded tinned copperTemperature MaxDry 105°CWet 75°COil 60°CTemperature Min -50°C
158Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Industrial Ethernet Double-Ended Cordsets for Ethernet/IP
0985 S4549 500 (Shielded, PUR Halogen Free Cable)
Description
Industrial Ethernet Double-Ended Cordset,
RJ45 to RJ45, 4 Conductors, 26 AWG, Stranded,
Shielded, 2 Twisted Pair, PUR, Halogen Free,
Water Blue Jacket.
Part Number
0985 S4549 500/1M
0985 S4549 500/10M
0985 S4549 500/20M
0985 S4549 500/30M
Face View Wiring Diagram
Pin Assignments
Technical Data
MaterialsPlug PolycarbonateContacts Phosphor Bronze, gold platedBoot Elastomer PolyolefinShell Copper Alloy, nickel plated
MechanicalTemperature -20°C to 75°CProtection IP 20
Cable SpecificationsCable Type CAT5e Industrial EthernetNo. Pairs 2 (4 conductors)Gauge 26 AWG, stranded
Outer Jacket Material PUR, halogen freeOutside Diameter 5.8 mmColor Water Blue
ShieldingFoil Aluminum laminated plastic Braid Tinned Copper, 85% coverage
1 = white/orange2 = orange3 = white/green6 = greenMetal Case = shield
159www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Industrial Ethernet Field Attachable Connectors for Ethernet/IP
0986 EMC 102
Description
Field attachable connector, M12 male
connector with threaded joint, shieldable,
assembling with spring-type terminals
4 poles, D coding.
Part Number
0986 EMC 102
M12 (D-Coding)
Technical Data
MaterialsHousing / Molded body GD-ZnAl, pre-coppered and nickel-platedInsert PAContact Stainless steel, silver-plated, gold-platedReceptacle shell CuZn, nickel-platedShield sleeve CuBe, tin-platedO-ring FKM
MechanicalOperating temperature 25°C / +90°CDegree of protection IP 67Mode of connection Spring-type terminalsScrew Joint for cable Ø 4,0–9,0 mm
ElectricalContact resistance ≤ 5 mΩNominal current at 40°C 4 ANominal voltage 120 VRated voltage 125 VTest voltage 1.5 kV eff. / 60 sInsulation resistance > 10° WPollution degree 3
Pin Assignments
160Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Industrial Ethernet Accessories
0986 EMC 500 | 503
Description
0986 EMC 500
RJ45 connector, category 5, high performance
RJ45 8-pin modular plugs for solid, shielded 24
AWG cables (909656).
0986 EMC 503
RJ45 connector, category 5, high performance
RJ45 8-pin modular plugs for stranded,
unshielded 24 AWG cables (909706).
Part Number
0986 EMC 500
0986 EMC 503
RJ45
Technical Data
MaterialsPlug PolycarbonateContacts Phosphor bronze, gold platedShell Copper alloy, nickel platedBoot Elastomer polyolefin
MechanicalTemperature -20°C to 70°C
Packaging SpecificationsItems come packaged 25 plugs and 25 boots per bag.
Pin Assignments
161www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Industrial Ethernet Accessories
0989 EAC 500
Description
Professional RJ45 premium grade hand
tool, designed to terminate modular plug
connectors on to stranded or solid,
shielded round cable.
Part Number
0989 EAC 500
162Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LAN connection M12, D-Coded Power supply 7/8” Input/Output M12
1 = +24 V2 = IN/OUT B3 = GND (0 V)4 = IN/OUT A5 = earthHousing = FE
1 = +24 V Actuators2 = +24 V Logic / Sensors3 = GND (0 V) Logic / Sensors4 = GND (0 V) ActuatorsHousing = FE
LioN-M EtherNet/IP-Device
0980 ESL 710 8 Port EtherNet/IP-Device
EtherNet/IP Device with 16 digital I/O channels, channels can be used universally as inputs or outputs, M12 socket, rotary address switches for addressing, M12 LAN-Ports, D-coded, 7/8“ power supply.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Pin Assignment
1 = TD+2 = RD+3 = TD-4 = RDHousing = shielding
Bit Assignment
Bit 7 6 5 4 3 2 1 0
M12 Input
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
Byte 1 8B 8A 7B 7A 6B 6A 5B 5A
M12 Output
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
Byte 1 8B 8A 7B 7A 6B 6A 5B 5A
Diagnostic Indication
LED Indication Condition
1...8 A yellow channel status 1
1...8 DIA A red periphery fault
1... 8 B yellow channel status 2
1... 8 DIA B red periphery fault
US greenoff
sensor power supply appliedsensor power supply missing
UL greenoff
actuator power supply appliedactuator power supply missing
P1 Lnk/Act greenyellow flashing
connected to an Ethernet deviceI/O device exchanging data
P2 Lnk/Act greenyellow flashing
connected to an Ethernet deviceI/O device exchanging data
MS(Module status)
greengreen flashingred/green flashingred flashingoff
device is ready for operatingwrong configurationself test is runningfirmware updatedevice is off
NS(Network status)
greengreen flashingredred flashingoff
connection to master existsIP address exists, but no connection to the masterIP address is used by a different deviceconnection has timed outdevice is off
163www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
LioN-M EtherNet/IP-Device0980 ESL 710
Technical Data
Environmental
Degree of protection IP 67Operating temperature range -10°C (+14°F) to +60°C (+140°F)
Mechanical
Weight 380 gHousing material PBT
Bus system Ethernet/IP
Transmission rate 10/100 MbsAddress range 0-255Rotary address switches 0-255Default address 1
System/Sensors power supply System power supply
Rated voltage 24 V DCVoltage range 11–30 V DCPower consumption typ. 90 mAReverse polarity protection yes
Input power supply US
Voltage range 19–30 V DCSensor current 200 mA (at Tamb 30°C)Short-circuit proof yesIndication LED green
Inputs Type 3 acc. to IEC 61131-3
Rated input voltage 24 V DCChannel type N.O. p-switchingNumber of digital channels max. 16Channel status indicator LED yellow per channelDiagnostic indication LED red per socket
Part Number
0980 ESL 710
The application of these products in harsh environments should always be checked before use. Specifications subject to alteration.
Output power supply UL
Rated voltage 24 V DCVoltage range 19–30 V DCReverse polarity protection yes/antiparallel diodeIndication LED green
Outputs
Rated output current 1.6 A per channelShort-circuit proof yesMax. output current 9 A (12 A*) per module*Test proven and approved under the following conditions:· looped through System/ Sensorpower supply max. 2,5 A· Power supply cable STL 204 (5x1.00 mm2)· Operating temperature range max. 40°C
Overload-proof yes
Number of digital channels max. 16Channel type N.O. p-switchingChannel status indicator LED yellow per channelDiagnostic indication LED red per socket
Included in delivery/accessories
Dust covers M12 2 piecesAttachable labels 10 pieces
164Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
LAN connection M12, D-Coded Power supply 7/8” Input M12
1 = +24 V2 = IN B3 = GND (0 V)4 = IN A5 = earthHousing = FE
1 = +24 V Actuators 1
2 = +24 V Logic / Sensors3 = GND (0 V) Logic / Sensors4 = GND (0 V) ActuatorsHousing = FE
1 In 16DI devices only for pass through
LioN-M EtherNet/IP-Device
0980 ESL 711 8 Port EtherNet/IP-Device
EtherNet/IP Device with 16 digital inputs, M12 socket, rotary address switches for addressing, M12 LAN-Ports, D-coded, 7/8“ power supply.
NOTE: This device can only be used when
obtaining written approval from AME Controls
Engineering.
Pin Assignment
1 = TD+2 = RD+3 = TD-4 = RDHousing = shielding
Bit Assignment
Bit 7 6 5 4 3 2 1 0
M12 Input
Byte 0 4B 4A 3B 3A 2B 2A 1B 1A
Byte 1 8B 8A 7B 7A 6B 6A 5B 5A
Diagnostic Indication
LED Indication Condition
1...8 A yellow channel status 1
1...8 DIA A red periphery fault
1... 8 B yellow channel status 2
1... 8 DIA B red periphery fault
US greenoff
sensor power supply appliedsensor power supply missing
P1 Lnk/Act greenyellow flashing
connected to an Ethernet deviceI/O device exchanging data
P2 Lnk/Act greenyellow flashing
connected to an Ethernet deviceI/O device exchanging data
MS(Module status)
greengreen flashingred/green flashingred flashingoff
device is ready for operatingwrong configurationself test is runningfirmware updatedevice is off
NS(Network status)
greengreen flashingredred flashingoff
connection to master existsIP address exists, but no connection to the masterIP address is used by a different deviceconnection has timed outdevice is off
165www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
LioN-M EtherNet/IP-Device0980 ESL 711
Technical Data
Environmental
Degree of protection IP 67Operating temperature range -10°C (+14°F) to +60°C (+140°F)
Mechanical
Weight 380 gHousing material PBT
Bus system Ethernet/IP
Transmission rate 10/100 MbsAddress range 0-255Rotary address switches 0-255Default address 1
System/Sensors power supply System power supply
Rated voltage 24 V DCVoltage range 11–30 V DCPower consumption typ. 90 mAReverse polarity protection yes
Input power supply US
Voltage range 19–30 V DCSensor current 200 mA (at Tamb 30°C)Short-circuit proof yesIndication LED green
Inputs Type 3 acc. to IEC 61131-3
Rated input voltage 24 V DCChannel type N.O. p-switchingNumber of digital channels max. 16Channel status indicator LED yellow per channelDiagnostic indication LED red per socket
Part Number
0980 ESL 711
The application of these products in harsh environments should always be checked before use. Specifications subject to alteration.
Included in delivery/accessories
Dust covers M12 2 piecesAttachable labels 10 pieces
166Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
Part Number Index
0905 204 301/5M 750905 204 301/10M 750905 204 301/15M 750905 204 302/0.6M 750905 204 302/10M 750910 ASL 132 820910 ASL 133 880910 ASL 134 940910 ASL 135 1000910 ASL 146 1020910 ASL 403 860910 ASL 408 980910 ASL 409 800910 ASL 410 920910 ASL 412 840910 ASL 414 960910 ASL 419 900910 ASL 438 1040910 ASL 501 780911 ANC 002/5M 1080911 ANC 002/10M 1080911 ANC 101 1100911 ANC 401 1100911 ANC 403 1090911 ANC 406 1120911 ANC 407/2M 1110911 ANC 407/5M 1110911 ANC 407/10M 1110911 ANC 408 1120911 ANC 409 1140911 ANC 410/0.3M 1110911 ANC 410/0.6M 1110911 ANC 410/1M 1110911 ANC 410/2M 1110911 ANC 410/5M 1110911 ANC 410/10M 1110911 ANC 410/15M 1110911 ANC 413 1120911 ANC 415 1120913 ATL 002/0.35M 1130913 ATL 003 1130915 097 000/50M 1060915 098 000/50M 1060915 145 000/50M 1070915 146 000/50M 1070940 ESL 601 1220940 PSL 601 1160940 PSL 602 1180940 PSL 603 1200941 UNC 601 1480942 UEM 600 1240942 UEM 601 1260942 UEM 602 1280942 UEM 612 1300942 UEM 620 1320942 UEM 630 1340942 UEM 631 1360942 UEM 670 138
Part Number Page No. Part Number Page No. Part Number Page No.
0942 UEM 700 1400942 UEM 701 1420942 UEM 782 1440942 UEM 783 1460970 PSL 650 680970 PSL 651 700970 PSL 700 640970 PSL 701 660975 254 101/2M 730975 254 101/3M 730975 254 101/4M 730975 254 101/5M 730975 254 102/2M 720975 254 102/3M 720975 254 102/4M 720975 254 102/5M 720975 254 103/2M 720975 254 103/3M 720975 254 103/4M 720975 254 103/5M 720975 254 104/2M 740975 254 104/3M 740975 254 104/4M 740975 254 104/5M 740975 254 105/2M 740975 254 105/3M 740975 254 105/4M 740975 254 105/5M 740976 PFC 101 760976 PMC 101 760976 PTX 101 770980 ESL 710 1620980 ESL 711 1640981 ENC 100 1510982 EEC 100 1500985 342 100/1M 1520985 342 100/2M 1520985 342 100/3M 1520985 342 100/5M 1520985 656 500/0.5M 1530985 656 500/1M 1530985 656 500/2M 1530985 656 500/5M 1530985 656 500/10M 1530985 706 100/0.5M 1560985 706 100/1M 1560985 706 100/2M 1560985 706 100/5M 1560985 706 100/10M 1560985 706 101/0.5M 1570985 706 101/1M 1570985 706 101/2M 1570985 706 101/5M 1570985 706 101/10M 1570985 706 103/0.5M 1540985 706 103/1M 1540985 706 103/2M 1540985 706 103/5M 154
0985 706 103/10M 1540985 706 104/0.5M 1550985 706 104/1M 1550985 706 104/2M 1550985 706 104/5M 1550985 706 104/10M 1550985 S4549 500/1M 1580985 S4549 500/10M 1580985 S4549 500/20M 1580985 S4549 500/30M 1580986 EMC 102 1590986 EMC 500 1600986 EMC 503 1600989 EAC 500 161ASB 4/LED 5/4-328/RS120M 40ASB 8/LED 5/4-331/RS120 41ASB2-RKT 4-3-645/0.3M 47ASB2-RKT 4-3-645/0.6M 47ASB2-RKT 4-3-645/1.5M 47ASB2-RKT 4-3-645/1M 47ASB2-RKT 4-3-645/2M 47ASB2-RKT 4-3-645/5M 47ASBM 4/LED 3-343/5M 54ASBM 4/LED 3-343/10M 54ASBM 8/LED 3-345/5M 55ASBM 8/LED 3-345/10M 55ASBS 2 M8 60ASBS2 M12 S2326 48ASBSV 4/LED 5 38ASBSV 8/LED 5 38RK 40-839/1M 6RK 40-839/2M 6RK 40-839/3M 6RK 40-839/5M 6RK 40-839/10M 6RK 40-839/20M 6RK 50-777/6F 8RK 50-777/12F 8RK 50-777/15F 8RK 50-777/20F 8RK 50-777/25F 8RK 50-777/30F 8RK 50-877/1M 6RK 50-877/2M 6RK 50-877/3M 6RK 50-877/5M 6RK 50-877/10M 6RK 50-877/20M 6RK 80M-650/6F 10RK 80M-650/12F 10RK 80M-650/15F 10RK 80M-650/20F 10RK 80M-650/30F 10RK 90M-751/1M 11RK 90M-751/2M 11RK 90M-751/3M 11RK 90M-751/5M 11RK 90M-751/10M 11
167www.lumberg-automationusa.com Phone: 1-717-217-2299
©2011, Belden, Inc.
Chrysler Project BookRevison 8.5, January 2012
Part Number Index
Part Number Page No. Part Number Page No. Part Number Page No.
RK 90M-751/20M 11RK 100M-652/6F 12RK 100M-652/12F 12RK 100M-652/15F 12RK 100M-652/20F 12RK 100M-652/30F 12RK 100M-752/1M 13RK 100M-752/2M 13RK 100M-752/3M 13RK 100M-752/5M 13RK 100M-752/10M 13RK 100M-752/20M 13RK 120M-676/6F 14RK 120M-676/12F 14RK 120M-676/15F 14RK 120M-676/20F 14RK 120M-676/25F 14RK 120M-676/30F 14RK 120M-776/1M 15RK 120M-776/2M 15RK 120M-776/3M 15RK 120M-776/5M 15RK 120M-776/10M 15RK 120M-776/20M 15RK 190M-699/5M 14RK 190M-699/10M 14RK 190M-699/15M 14RK 190M-769/1M 15RK 190M-769/2M 15RK 190M-769/3M 15RK 190M-769/5M 15RK 190M-769/10M 15RK 190M-769/20M 15RKC 4/7 50RKCW 4/7 50RKF 1001M-699/1F 35RKF 1201M-624/1F 37RKF 401-639/1F 30RKF 4-1/2-14/0.5M 49RKF 5 TB 52RKF 801-698/1F 33RKMCK 3 62RKMV 3-224/2M 56RKMV 3-224/5M 56RKMV 3-224/10M 56RKMWV 3-224/2M 57RKMWV 3-224/5M 57RKMWV 3-224/10M 57RKT 4-602/2M 42RKT 4-602/5M 42RKT 4-602/10M 42RKT 4-637/2M 42RKT 4-637/5M 42RKT 4-637/10M 42RKT 4-643/2M 42RKT 4-643/5M 42RKT 4-643/10M 42RKU 19-242/5M 39
RKU 19-242/10M 39RKU 19-242/15M 39RKU 19-242/20M 39RKW 40-839/1M 7RKW 40-839/2M 7RKW 40-839/3M 7RKW 40-839/5M 7RKW 40-839/10M 7RKW 40-839/20M 7RKW 50-777/6F 9RKW 50-777/12F 9RKW 50-777/15F 9RKW 50-777/20F 9RKW 50-777/25F 9RKW 50-777/30F 9RKW 50-877/1M 7RKW 50-877/2M 7RKW 50-877/3M 7RKW 50-877/5M 7RKW 50-877/10M 7RKW 50-877/20M 7RKWT 4-602/2M 44RKWT 4-602/5M 44RKWT 4-602/10M 44RKWT 4-637/2M 44RKWT 4-637/5M 44RKWT 4-637/10M 44RKWT 4-643/2M 44RKWT 4-643/5M 44RKWT 4-643/10M 44RKWU 19-242/5M 39RKWU 19-242/10M 39RKWU 19-242/15M 39RKWU 19-242/20M 39RSC 4/7 51RSCW 4/7 51RSF 120M-676/1F 36RSF 40-639/1F 31RSF 4-1/2-14/0.5M 49RSF 5 TB 53RSF 50-677/1F 32RSF 80M-698/1F 34RSMCK 3 62RSMF 3/0.5M 61RSMV 3-RKMV 3-224/0.6M 58RSMV 3-RKMV 3-224/1M 58RSMV 3-RKMV 3-224/2M 58RSMV 3-RKMWV 3-224/0.6M 59RSMV 3-RKMWV 3-224/1M 59RSMV 3-RKMWV 3-224/2M 59RSRK 40-839/1M 16RSRK 40-839/2M 16RSRK 40-839/3M 16RSRK 40-839/5M 16RSRK 40-839/10M 16RSRK 40-839/20M 16RSRK 401-637/6F 20RSRK 401-637/12F 20
RSRK 401-637/15F 20RSRK 401-637/20F 20RSRK 401-637/30F 20RSRK 401-839/1M 17RSRK 401-839/2M 17RSRK 401-839/3M 17RSRK 401-839/5M 17RSRK 401-839/10M 17RSRK 401-839/20M 17RSRK 50-877/1M 16RSRK 50-877/2M 16RSRK 50-877/3M 16RSRK 50-877/5M 16RSRK 50-877/10M 16RSRK 50-877/20M 16RSRK 501-877/1M 17RSRK 501-877/2M 17RSRK 501-877/3M 17RSRK 501-877/5M 17RSRK 501-877/10M 17RSRK 501-877/20M 17RSRK 501M-777/6F 21RSRK 501M-777/12F 21RSRK 501M-777/15F 21RSRK 501M-777/20F 21RSRK 501M-777/30F 21RSRK 801M-650/6F 22RSRK 801M-650/12F 22RSRK 801M-650/15F 22RSRK 801M-650/20F 22RSRK 801M-650/25F 22RSRK 801M-650/30F 22RSRK 90M-751/1M 23RSRK 90M-751/2M 23RSRK 90M-751/3M 23RSRK 90M-751/5M 23RSRK 90M-751/10M 23RSRK 90M-751/20M 23RSRK 901M-751/1M 24RSRK 901M-751/2M 24RSRK 901M-751/3M 24RSRK 901M-751/5M 24RSRK 901M-751/10M 24RSRK 901M-751/20M 24RSRK 100M-752/1M 26RSRK 100M-752/2M 26RSRK 100M-752/3M 26RSRK 100M-752/5M 26RSRK 100M-752/10M 26RSRK 100M-752/20M 26RSRK 1001M-699/6F 27RSRK 1001M-699/15F 27RSRK 1001M-752/1M 25RSRK 1001M-752/2M 25RSRK 1001M-752/3M 25RSRK 1001M-752/5M 25RSRK 1001M-752/10M 25RSRK 1001M-752/20M 25
168Chrysler Project BookRevison 8.5, January 1, 2012
Phone: 1-717-217-2299©2011, Belden, Inc.
www.lumberg-automationusa.com
RSRK 120M-776/1M 30RSRK 120M-776/2M 30RSRK 120M-776/3M 30RSRK 120M-776/5M 30RSRK 120M-776/10M 30RSRK 120M-776/20M 30RSRK 1201M-676/6F 28RSRK 1201M-676/12F 28RSRK 1201M-676/15F 28RSRK 1201M-676/20F 28RSRK 1201M-676/25F 28RSRK 1201M-676/30F 28RSRK 1201M-776/1M 29RSRK 1201M-776/2M 29RSRK 1201M-776/3M 29RSRK 1201M-776/5M 29RSRK 1201M-776/10M 29RSRK 1201M-776/20M 29RSRK 190M-769/1M 30RSRK 190M-769/2M 30RSRK 190M-769/3M 30RSRK 190M-769/5M 30RSRK 190M-769/10M 30RSRK 190M-769/20M 30RSRK 1901M-669/2M 28RSRK 1901M-669/5M 28RSRK 1901M-669/10M 28RSRK 1901M-769/1M 29RSRK 1901M-769/2M 29RSRK 1901M-769/3M 29RSRK 1901M-769/5M 29RSRK 1901M-769/10M 29RSRK 1901M-769/20M 29RSRKW 401-839/1M 20RSRKW 401-839/2M 20RSRKW 401-839/3M 20RSRKW 401-839/5M 20RSRKW 401-839/10M 20RSRKW 401-839/20M 20RSRKW 40-839/1M 19RSRKW 40-839/2M 19RSRKW 40-839/3M 19RSRKW 40-839/5M 19RSRKW 40-839/10M 19RSRKW 40-839/20M 19RSRKW 501-877/1M 20RSRKW 501-877/2M 20RSRKW 501-877/3M 20RSRKW 501-877/5M 20RSRKW 501-877/10M 20RSRKW 501-877/20M 20RSRKW 50-877/1M 19RSRKW 50-877/2M 19RSRKW 50-877/3M 19RSRKW 50-877/5M 19RSRKW 50-877/10M 19RSRKW 50-877/20M 19RST 4-602/1M 44RST 4-RKT 4-602/0.3M 46RST 4-RKT 4-602/0.6M 46
Part Number Index
RST 4-RKT 4-602/1M 46RST 4-RKT 4-602/2M 46RST 4-RKT 4-602/3M 46RST 4-RKT 4-602/5M 46RST 4-RKT 4-637/0.3M 46RST 4-RKT 4-637/0.6M 46RST 4-RKT 4-637/1M 46RST 4-RKT 4-637/2M 46RST 4-RKT 4-637/3M 46RST 4-RKT 4-637/5M 46RST 4-RKT 4-643/0.3M 46RST 4-RKT 4-643/0.6M 46RST 4-RKT 4-643/1M 46RST 4-RKT 4-643/2M 46RST 4-RKT 4-643/3M 46RST 4-RKT 4-643/5M 46RST 4-RKWT 4-602/0.3M 47RST 4-RKWT 4-602/0.6M 47RST 4-RKWT 4-602/1M 47RST 4-RKWT 4-602/2M 47RST 4-RKWT 4-602/3M 47RST 4-RKWT 4-602/5M 47RST 4-RKWT 4-637/0.3M 47RST 4-RKWT 4-637/0.6M 47RST 4-RKWT 4-637/1M 47RST 4-RKWT 4-637/2M 47RST 4-RKWT 4-637/3M 47RST 4-RKWT 4-637/5M 47RST 4-RKWT 4-643/0.3M 47RST 4-RKWT 4-643/0.6M 47RST 4-RKWT 4-643/1M 47RST 4-RKWT 4-643/2M 47RST 4-RKWT 4-643/3M 47RST 4-RKWT 4-643/5M 47ZBS 116ZLU 4-50 5ZVK 117
Part Number Page No. Part Number Page No.