www.aemc.com Technical Assistance (800) 343-1391
POWER QUALITY ANALYZERS, METERS & LOGGERS Three-Phase Power Quality Analyzer
SD card memory capacity for trend data storage: Up to 50 captured snapshots, 210 captured transients, 1 inrush and 10,000 alarm events
PowerPad® III Model 8435
KIT OPTION INCLUDES
Extra large tool bag, accessory pouch, 5 ft USB cable, five 10 ft black voltage leads with alligator clips, 110V US power cord, four water-tight AmpFlex® 196A-24-BK (included with Cat. #2136.42 only), NiMH battery, SD card, twelve color-coded input ID markers, quick start guide, and a USB stick containing DataView® software and user manual.
8435 Kit
SPECIFICATIONSMODEL 8435ELECTRICALSampling Frequency 256 samples/cycleData Storage SD card for trend recording;
Additional separate 12.5MB partitioned memory for snapshots, transient/inrush & alarms
Voltage (TRMS) Phase-to-Phase: 2000V Phase-to-Neutral: 1000V
Voltage Ratio: up to 500kVCurrent (TRMS) MN Clamp: 0 to 6A/120A or 0 to 240A
SR Clamp: 0 to 1200AMR Clamp: 0 to 1000Aac, 0 to 1400Adc
MiniFlex®: 10 to 3000A AmpFlex®: 10 to 10kA(1)
SL261 Clamp: 50mA to 100Aac/dc J93: 50 to 3500Aac/dc
Current Ratio: 10mA to 50kA
Frequency (Hz) 40 to 69HzOther Measurements kW, kvar, kVA, PF, DPF, kWh, kvarh, kVAh, K-Factor, FlickerHarmonics 1st to 50th, Direction, SequencePower Source 9.6V NiMH rechargeable battery pack (included)
External AC supply: 110/230Vac ±10% (50/60Hz)Battery Life ≥8 hours with display on; ≤35 hours with display off
(record mode)MECHANICALCommunication Port Optically isolated USBDisplay ¼ VGA (320 x 240) color LCD display with adjustable
brightness & contrastDimensions 10.6 x 9.8 x 7.1" (270 x 250 x 180mm)Weight 8.2 lbs (3.7kg) with batteriesSafety Rating EN 61010, 600V CAT IV(2), 1000V CAT III, Pollution Degree 2
(1)Crest factor at 6500 = 1 (2)When used with SR193 or AmpFlex® probes. 600V CAT III with MN193 or MR193 probes.
Four current and four voltage input terminals
FEATURES• Measurement of TRMS voltages up to 1000Vrms AC/
DC for two-, three-, four- or five-wire systems• Measurement of TRMS currents up to 6500Arms
(sensor dependent)• Direct measurement of neutral current & voltage• Frequency measurement (40 to 69Hz systems)• Record and display trend data as fast as once
per second for one month for up to 25 variables• Transient detection on all V and I inputs (up to 210)• Selectable PT and CT ratios• Inrush current measurement• Calculation of Crest Factors for V and A• Calculation of the K-Factor for transformers• Calculation of short-term flicker and three-phase
voltage unbalance• Measures harmonics (referenced to the fundamental
or RMS value) for voltage, current or power, up to 50th
harmonic• Displays of harmonic sequencing and
direction and calculation of overall harmonics• Real-time display of phasor diagrams
including values and phase angles• Measurement of active, reactive and apparent power
per phase and their respective sum total• Calculation of power factor, displacement power factor
and tangent factor• Recording, time stamping and characterization of
disturbance (swells, sags and interruptions,exceedence of power and harmonic thresholds)
• 2GB internal Trend Recording memory; Alarm,Snapshot and Transient/Inrush memories are separate
• Measurement of energy VAh, varh & Wh• The Max and Min RMS measurements are
calculated every half-period• Includes DataView® software for configuring, real-time
display, analysis and report generation• 65μs/sample transient recording
Special product features
▼
2GB
MEMORY
CAPT
RE TRANSIEN
TS
TRE
ND
RECORDIN
G
''''
R AT I N G
SAFETYIP
Rated67
cover closed
33WARRANT
Y
YEAR*
* Registration must take place within 30 days of purchase
Original
cover closed
Technical Assistance (800) 343-1391 www.aemc.com
CATALOG NO. DESCRIPTION
2136.41 PowerPad® III Model 8435 (No Sensors - Waterproof IP67)2136.42 PowerPad® III Model 8435 w/4 A196-24-BK (AmpFlex® - Waterproof IP67)Accessories (Optional)2133.73 Extra Large Classic Tool Bag2140.72 Replacement accessory pouch (accessories not included)2140.19 Replacement – Battery 9.6V NiMH2140.28 AC Current Probe Model MR193-BK2140.32 AC Current Probe Model MN93-BK2140.33 AC Current Probe Model SR193-BK2140.35 AmpFlex® Sensor 36" Model 193-36-BK2140.36 AC Current Probe Model MN193-BK 2140.45 Replacement – Set of 12, Color-coded Input ID Markers2140.46 Replacement – 5 ft USB Cable2140.48 MiniFlex® Sensor 10" Model MA193-10-BK2140.49 AC/DC Current Probe Model J93-BK
2140.73 Lead – One 10 ft (3M) Black Lead (Waterproof cap) [Rated 1000V CAT IV] & one Black Alligator Clip [Rated 1000V CAT IV, 15A,UL]
2140.75 AmpFlex® Sensor 24" (waterproof - IP67) Model A196-24-BK
Configuration
Inrush Peak
Trend Analyze
Phasor Diagram
Harmonics Mode
Transient Mode
PowerPad® III Model 8435
Large Color Functional DisplaysInstallation of the Leads and Current SensorsColor-coded ID markers are supplied with the PowerPad® III to identify the leads and input terminals.
Cat. #5000.63
Cat. #2140.73
Cat. #2140.75 (For Cat. #2136.42 only)
The voltage and current inputs, as well as the
power cord connection are constructed with screw on, watertight connectors rated to
IP67.
www.aemc.com Technical Assistance (800) 343-1391
POWER QUALITY ANALYZERS, METERS & LOGGERS Optional Accessories
SENSOR TYPE CURRENT RANGE ACCURACY (TYPICAL)
TYPICAL ERROR
ON Φ AT 50/60HZ
MAX CONDUCTOR
SIZE
USED WITH MODEL
LIMITED RANGE IF
USED WITH MODEL
CATALOG NUMBER
MiniFlex® MA193-BK *
100mA to 3000Aac ±1% 0° 2.75" (70mm)
PEL 102 PEL 103 PEL 105
8333 8336
8220 8230 8435
2140.48 (10" sensor)
2140.50 (14" sensor)
MR193-BK
1 to 1000Aac
1 to 1300Adc±2.5% -0.80° 1.6"
(41mm)
8220 8230
PEL 102 PEL 103 PEL 105
8333 8336 8435
N/A 2140.28
SR193-BK
1 to 1200Aac ±0.3% 0.2° 2.05" (52mm)
8220 8230
PEL 102 PEL 103 PEL 105
8333 8336 8435
N/A 2140.33
AmpFlex® 193-BK *
100mA to 12,000Aac ±1% 0°
7.64" (190mm)
or11.46"
(290mm)
PEL 102 PEL 103 PEL 105
8333 8336
8220 8230 8435
2140.34 (24" sensor)
2140.35 (36" sensor)
AmpFlex® A196
10 to 10,000Aac ±2% 0° 5.73" (145mm)
PEL 105 8435 N/A 2140.75
(24" sensor)
* Maximum current reduced by a factor of 2 for 400Hz fundamental frequency.
Battery operated
10" or 14" sensor
24" or 36" sensor
24" sensor IP67
Technical Assistance (800) 343-1391 www.aemc.com
POWER QUALITY ANALYZERS, METERS & LOGGERS Optional Accessories
SENSOR TYPE CURRENT RANGE ACCURACY (TYPICAL)
TYPICAL ERROR
ON Φ AT 50/60HZ
MAX CONDUCTOR
SIZE
USED WITH MODEL
LIMITED RANGE IF
USED WITH MODEL
CATALOG NUMBER
MN93-BK
0.5 to 240Aac ±1% 0.8° 0.78" (20mm)
PEL 102 PEL 103 PEL 105
8333 8336 8435
8220 8230 2140.32
MN193-BK
100A 200mA to 120Aac ±1% 0.75°
0.78" (20mm)
8220 8230
PEL 102 PEL 103 PEL 105
8333 8336 8435
N/A 2140.36
5A 5mA to 6Aac ±1% 1.7°
SL261 **
100A 5 to 100Aac/dc ±4% ±0.5°
0.46" (11.8mm)
8220 8230
PEL 102 PEL 103 PEL 105
8333 8336 8435
N/A 1201.51
10A 50mA to 10Aac/dc ±3% ±1°
J93
50 to 3500Aac
50 to 5000Adc±1% ±1°
2.83" (72mm)
Busbar: 5 x 1.69"
(127 x 43mm)
PEL 102 PEL 103 PEL 105
8333 8336 8435
N/A 2140.49
Note: Refer to the Power Meter’s product user manual for complete specifications.
All current sensors can be used with the Models 8435 and PEL 105. However, only the A196 flexible sensors are waterproof.
** AC/DC Current Probe BNC Adapter for Model SL261 only Catalog #2140.40
Battery operated
Battery operated
CATALOG NO. DESCRIPTION
1201.51 AC/DC Current Probe Model SL261 (BNC)
2140.37 Adapter – US 110V Power Adapter (eliminates need for batteries) 8220 & 8230 only
2140.28 AC/DC Current Probe Model MR193-BK
2140.32 AC Current Probe Model MN93-BK
2140.33 AC Current Probe Model SR193-BK
2140.34 AmpFlex® Sensor 24" Model 193-24-BK
2140.35 AmpFlex® Sensor 36" Model 193-36-BK
2140.36 AC Current Probe Model MN193-BK
2140.48 MiniFlex® Sensor 10" Model MA193-10-BK
2140.49 AC/DC Current Probe Model J93-BK
2140.50 MiniFlex® Sensor 14" Model MA193-14-BK
2140.75 AmpFlex® Sensor 24" (waterproof - IP67) Model A196-24-BK
www.aemc.com Technical Assistance (800) 343-1391
Data Analysis and Reporting Software
DATAVIEW® Software for Power & Energy Loggers
Configure all functions of the Power & Energy Loggers
• Display and analyze real-time data on your PC
• Configure functions and parameters from your PC
• Customize views, templates and reports to your exact needs
• Create and store a complete library of configurations thatcan be uploaded as needed
• Zoom in and out and pan through sections of the graph to analyze the data
• Download, display and analyze recorded data
• Display waveforms, trend graphs, harmonic spectrums,text summaries, transients, event logs and stored alarms
• Print reports using standard or custom templates you design• Free updates are available on our website www.aemc.com
Typical DataView® Functional, Digital & Graphical Displays
Clear and easy setup of all functions from one tabbed dialog box.
Display power and energy parameters – both instantaneous and total.
Display harmonics in a text table from harmonic 0 (DC) through the 50th.Display real-time Phasor diagrams.
Includes unbalance for both voltage and current.
Display real-time waveforms by phase, parameter or total.
Display all harmonics from 1st to 50th in bar graph form for voltage, current and power.