specifications , building regulations, construction

1
I V E T S E Y R O A D B E L L H U R S T L A N E T1 T2 T3 T4 T5 H4 T9 T10 H4 H4 H1 H1 H1 H1 W W W W W W B03 B04 B05 B06 B07 B08 Aff-3b 7 Aff-3b 8 Aff-3b 9 Aff-3b 10 Drayton 11 Stretton 12 Stretton 13 Drayton 14 Aff-2b 18 Attenuation Pond P P P P P P P P P P P P P P P P P P P P P P P P P P P Wheaton 17 P P P P P P P P P Grasmere 15 Earlsdale 16 P P P P 2.4x43m visplay 2.4x43m visplay Existing 30mph signs, roundel and 'sharks teeth' markings to be removed 8 sets of 'Dragons Teeth' with 'Slow' legend White continuous marking - 'Virtual' road hump 30mph/NSL signs with yellow backing board 30mph/NSL signs with yellow backing board Proposed Access Existing hedge to be removed Start of 30mph speed limit to be moved to new gateway and the appropriate traffic order amended 30mph roundel marking Surface change - type tbc 6m 5m LEGEND - VISIBILITY SPLAYS - HEDGE TO BE - REMOVED SITE BOUNDARY - 2.4x43m visplay ACCESS ENTRY TREATMENT PLAN JS RH JAN 2021 1:200 @ A1 RACE/SH/WA ENG_160 IVETSEY ROAD, WHEATON ASTON SHROPSHIRE HOMES The Contractor is to check and verify all building and site dimensions, levels and sewer invert levels at connection points before work starts. The Contractor is to comply in all respects with current Building Legislation, British Standard Specifications , Building Regulations, Construction (Design & Management) Regulations, Party Wall Act, etc. whether or not specifically stated on this drawing. This drawing must be read with and checked against any structural, geotechnical or other specialist documentation provided. This drawing is not intended to show details of foundations, ground conditions or ground contaminants. Each area of ground relied upon to support any structure depicted (including drainage) must be investigated by the Contractor. A suitable method of foundation should be provided allowing for existing ground conditions. Any suspect or fluid ground, contaminates on or within the ground, should be further investigated by a suitable expert. Any earthwork constructions shown indicate typical slopes for guidance only & should be further investigated by a suitable expert. Where existing trees / structures are to be retained they should be subject to a full specialist inspection for safety. All trees are to be planted so as to ensure they are a minimum of 5 metres from buildings. A suitable method of foundation is to be provided to accommodate the proposed tree planting. Residential & Commercial Engineering Limited do not accept any responsibility for any losses (financial or otherwise) to any Client or third party arising out of the Clients (be it Developer or Contractor but not limited thereto) non- compliance with afore mentioned provisos. © This drawing is the property of Residential & Commercial Engineering Limited and may not be copied or used for any purpose other than that for which it is supplied without the express written authority of Residential & Commercial Engineering Limited. Revisions: Project: Title: Client: Drawn by: Checked by: Date: Scale: Job Number. Drawing No. Revision. # Contact us : Drawing Status: Residential & Commercial Engineering Ltd, Hednesford Town Football Club, Keys Park Road, Hednesford, Cannock, WS12 2DZ. Tel : 01922 411552 Rev Description Date Drawn Check PRELIMINARY - Subject to the following approvals: DoC - Subject to Technical Approval from SSC. S7 / S278 - Subject to Technical Approval from SCC. S104 - Subject to Technical Approval from STW. S106 - Developer to complete application/approval with STW.

Upload: others

Post on 22-Oct-2021

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Specifications , Building Regulations, Construction

I V E T S E Y R

O A D

B E

L L

H U

R S

T L

A N

E

T1

T2

T3

T4

T5

H4

T9

T10

H4

H4

H1

H1

H1

H1

W

W

W

W

W

W

B03

B04

B05

B06

B07

B08

Aff-3b7

Aff-3b8

Aff-3b9

Aff-3b10

Drayton11

Stretton12

Stretton 13

Drayton14

Aff-2b18

Attenuation

Pond

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

PP

P

P

P

P

P

P

P

Wheaton17

P

P

P

P

P

P

P

P P

Grasmere15

Earlsdale16

P

P

P

P

2

.

4

x

4

3

m

v

i

s

p

l

a

y

2

.

4

x

4

3

m

v

i

s

p

l

a

y

Existing 30mph signs, roundel

and 'sharks teeth' markings to

be removed

8 sets of 'Dragons Teeth' with

'Slow' legend

White continuous marking -

'Virtual' road hump

30mph/NSL signs with yellow

backing board

30mph/NSL signs with yellow

backing board

Proposed Access

Existing hedge to be removed

Start of 30mph speed limit to

be moved to new gateway

and the appropriate traffic

order amended

30mph roundel marking

Surface change - type tbc

6

m

5

m

LEGEND -

VISIBILITY SPLAYS -

HEDGE TO BE -

REMOVED

SITE BOUNDARY -

2.4x43m visplay

ACCESS ENTRY TREATMENT PLAN

JS

RH

JAN 2021

1:200 @ A1

RACE/SH/WA

ENG_160

IVETSEY ROAD,

WHEATON ASTON

SHROPSHIRE HOMES

The Contractor is to check and verify all building and site

dimensions, levels and sewer invert levels at connection

points before work starts. The Contractor is to comply in all

respects with current Building Legislation, British Standard

Specifications , Building Regulations, Construction (Design &

Management) Regulations, Party Wall Act, etc. whether or

not specifically stated on this drawing. This drawing must

be read with and checked against any structural,

geotechnical or other specialist documentation provided.

This drawing is not intended to show details of foundations,

ground conditions or ground contaminants. Each area of

ground relied upon to support any structure depicted

(including drainage) must be investigated by the Contractor.

A suitable method of foundation should be provided allowing

for existing ground conditions. Any suspect or fluid ground,

contaminates on or within the ground, should be further

investigated by a suitable expert. Any earthwork

constructions shown indicate typical slopes for guidance

only & should be further investigated by a suitable expert.

Where existing trees / structures are to be retained they

should be subject to a full specialist inspection for safety. All

trees are to be planted so as to ensure they are a minimum

of 5 metres from buildings. A suitable method of foundation

is to be provided to accommodate the proposed tree

planting.

Residential & Commercial Engineering Limited do not accept

any responsibility for any losses (financial or otherwise) to

any Client or third party arising out of the Clients (be it

Developer or Contractor but not limited thereto) non-

compliance with afore mentioned provisos.

© This drawing is the property of Residential & Commercial

Engineering Limited and may not be copied or used for any

purpose other than that for which it is supplied without the

express written authority of Residential & Commercial

Engineering Limited.

Revisions:

Project:

Title:

Client:

Drawn by:

Checked by:

Date:

Scale:

Job Number.

Drawing No.

Revision.#

Contact us :

Drawing Status:

Residential & Commercial Engineering Ltd,

Hednesford Town Football Club, Keys Park

Road, Hednesford, Cannock,

WS12 2DZ.

Tel : 01922 411552

Rev Description Date Drawn Check

PRELIMINARY - Subject to the following approvals:

DoC - Subject to Technical Approval from SSC.

S7 / S278 - Subject to Technical Approval from SCC.

S104 - Subject to Technical Approval from STW.

S106 - Developer to complete application/approval with STW.