specification - torfaen county borough · pdf filetree lta 3 liriodendron tulipfera ... spec...
TRANSCRIPT
+109
.0
+109
.0
+109.0
106.700
106.600
106.
700
105.900
105.900
525m
m @
1 in
70
105.
290
EXFWCL 108.500IL 106.000*
450m
m
+107
.5
+107
.5
+107.5
+107.5
+108.5
+109.0
+109
.0+107
.5
+109.0
+109.0
+109
.0
+107.5
+107
.5
+107.5
+109
.0
+109
.0
+108
.5EXSWCL 108.230IL 105.500*
52
SHED
Footpath Link
7
8
910 11
20
22
23
24
25
26
27
28
29
Greenmeadow Way
SHED
SHED
SHED
SHED
SHED
SHED
SHED
SHED
SHED SHED
SHED
Footp
ath L
ink
6
5
4
3
2
1
SHED
140141
142143
144145
146
147
148149
150
151
152
153
154
156
157
158159160161163164166167168169170
171172
173
174
175
176
177
178
179
180181
183
184
185
186-191
192-197
198
199
200
201
208
209210
211212
213
214 216
217
218
219
220
221
222
223
224
SHED
SHED
SHED
SHED
SUB
155
53
54
SHED
SHEDSHED
Footpath Link
Footpath Link
215
3-Cxp
4-Cxp
7-Cxp 7-Cxp
Mix in groups of 3-5no:6-HN6-HL
6-HLM
62-CsK
130-CsK
91-Cs-BR
33-Cs-BR
18-Iaq
13-Iaq
13-Iaq
37-Iaq
22-Cs-BR
44-Cs-BR
40-Cs-BR
42-Cal 23-Cal
51-Cal
31-Cal
21-CsK
21-CsK
Mix in groups of 2-3no.:5-CSP5-Cxp5-LG
Mix in groups of 2-3no.:6-CSP6-Cxp6-LG
12-CAP12-CAP
Mix in groups of 2-3no.:10-CSP10-Cxp10-LG
3-PS
7-PS
Mix in groups of 2-3no.:10-Cxp10-HL
10-PBS
4-RGW
5-RGW
6-RSS8-ScG
16-HL
9-HW
3-HAG
21-HAG
3-HAG
3-HAG
3-HAG
21-HAG
14-PG
10-CAP
8-CAP
5-PfR
7-PG
7-PfR7-Ctr
6-Ctr
10-HMB
3-PSQ
7-PG
12-PG2-LsC
2-LsC9-RMM 9-RMM
WFG8
WFG8
MG8 within basin
10-CAP
10-CAP11-CAP
Mix in groups of 2-3no.:3-CSP3-Cxp5-LG1-Vb
Mix in groups of 2-3no.:13-CSP13-Cxp20-LG5-Vb
11-SR
10-PfR
5-Hq
9-CAP
9-CAP11-SR
8-BSil
4-Aa
22-HAG
15-HAG
1-LsC
1-RG-7.5L
4-HM
8-HM
9-HM
9-HM
8-HM
12-CaSV
16-CaSV
8-SR
16-PBS
26-LLE
52-LLE
15-LLE
59-LLE
55-PdA60-PdA
47-PdA
60-PdA
Mix in groups of 3-5no:12-Hor12-HL
12-HLM
Mix in groups of 2-3no.:10-CSP10-Cxp10-LG
7-EGB
2-EGB
10-Cb11-HM
10-Ctr
5-CPC
5-PG
7-PG
6-PG
5-CaSV
13-Cb
3-CAP
9-CAP
44-HM11-HM
10-PtYW-3
10-PtYW-3
10-PtYW-3
10-PtYW-3
27-PtYW-3
21-PtYW-3
9-PtYW-3
9-PtYW-3
10-HW
11-HW
10-PSQ
10-PSQ
22-PdA
22-PdA
22-PdA
22-PdA
22-PdA
22-PdA
253-Cb
256-Cb
28-CsK
28-CsK
28-CsK
28-CsK
28-CsK
28-CsK
28-CsK
71-Cb
1-MR
58-Cb
1-MR
6-RGW
7-HAG3-PG
27-LLE
36-LLE
32-LLE
47-Cb
9-HM
12-CAP
8-EQ
24-HW11-CPC
13-EQ
15-Hor
1-CMW
15-HL
12-SaS
13-Hq
Mix in groups of 2-3no.:9-HPP9-Cxp9-LG
Mix in groups of 2-3no.:10-HPP10-Cxp10-LG
3-Hq
15-EQ
28-HL
10-HL
8-IfV
3-Hq
3-Hq
Mix in groups of 3-5no:5-HN5-HL
5-HLM
3-IfV
3-IfV
19-Cb
17-Cb
5-RGW
4-HMB
5-LaA
1-CMW
9-EQ
27-Cb
7-EQ
7-EQ
7-EQ
36-LLE
38-LLE
32-HM
11-EQ
6-CPC
6-CPC
6-EQ
14-HW
4-CbFF
1-CbFF
1-Pt1-Pt
1-Pt
1-Pt1-Pt
1-CIS1-CIS
1-CIS
1-CIS1-CIS
1-CIS1-CIS
22-Cb23-Cb
18-Cb
65-Cb
47-Cb
13-Cb
15-Cb
32-Cb
73-Cb
48-Cb
30-Cb
48-Cb
22-Cb
51-Cb
28-Cb
22-Cb
24-Cb
29-Cb
56-Cb
17-Cb
36-Cb
19-Cb
13-Cb
21-Cb 8-Cb 14-Cb
9-HM
16-HM
14-HM9-HM
10-HM
9-HM
21-HM
14-HM
2-SaM
1-SaM
1-SaM
1-SaM
1-SaM
1-SaM
1-MR
1-MR
1-Asp
1-Asp
1-Asp
1-CbFF
1-CaG
1-CaG
1-Asp
1-ARH
1-ARH
1-SaM
1-SaM
3-Asp
2-Asp
3-Asp
1-Asp
1-SaM
1-SaM
1-PtYW-15
1-SaM
4-CbFF
1-CbFF
2-CbFF
2-CbFF1-CbFF
3-Asp
3-CbFF
1-CbFF
1-CbFF
16-PBS
1-SaM
1-SaM 1-SaM
n
proposed trees
proposed shrub beds
legend
proposed turf
proposed hedge
existing trees and hedge to be retainedshowing RPA
protective tree fencing
wildflower seeding; for mixes refer to notes aboveMG8
proposed back gardens (cultivated soil)
Spacing ID No. Latin Name Scheduled Size4/m2 Aa 42 Arundinaria auricoma 30-40cm, 3L Minimum of 3 stems
TREE ARH 3 Amelanchier 'Robin Hill' 12-14cm 45L Std 2m clear stemTREE Asp 24 Alnus spaethii 14-16cm Rootballed4/m2 BSil 30 Bergenia 'Silberlicht' 30-40, 5L Full pot
CONIFER CaG 2 Cedrus atlantic 'Glauca' 3.5m 110L2/m2 Cal 147 Cornus alba 60-90cm, BR 1+24/m2 CAP 176 Choisya 'Aztec Pearl' 30-40cm, 3L 5 breaks in lower third4/m2 CaSV 113 Cornus alba 'Sibirica Variegata' 30-40cm, 3L 3 breaks in lower third
5/linm Cb 2266 Carpinus betulus 60-80cm, BRTREE CbFF 43 Carpinus betulus 'Frans Fontaine' 20-25cm RB 2.5m clear stem
CLIMBER CIS 7 Ceanothus 'Italian Skies' 1.2-1.5m, 15L Trained on timber frameTREE CMW 7 Cornus 'Celestial Shadow' 15L 1.2-1.4m4/m2 CPC 88 Cotinus coggyria 'Purple Cloak' 30-40cm, 3L 3 breaks in lower third2/m2 Cs-BR 230 Cornus sanguinea 60-90cm, BR 1+24/m2 CsK 861 Cornus stolonifera 'Kelseyi' 30-40cm, 3L Bushy4/m2 CSP 89 Cistus 'Silver Pink' 20-30cm, 3L 3 breaks in lower third4/m2 Ctr 171 Ceanothus thyrsiflorus 'Repens' 30-40cm, 3L Bushy 4/m2 Cxp 137 Cistus x purpureus 20-30cm, 3L 3 breaks in lower third
EA 113 Escallonia 'Apple Blossom' 30-40cm, 3L 3 breaks in lower third4/m2 EGB 36 Escallonia exoniensis 'Gold Brian' 30-40cm, 3L 3 breaks in lower third4/m2 EQ 139 Elaeagnus 'Quicksilver' 30-40cm, 3L 3/4 breaks in lower third, bushy
SPEC Fj 5 Fatsia japonica 60-80cm, 10L 5 breaks in lower third4/m2 HAG 166 Hebe 'Autumn Glory' 20-30cm, 3L Bushy, 3 breaks in lower third4/m2 HBC 5 Heuchera 'Beauty Colour' 20-30cm, 3L Full pot5/m2 HL 168 Heuchera 'Licorice' 20-30cm, 3L Full pot5/m2 HLM 55 Heuchera 'Lime Marmalade' 20-30cm, 3L Full pot
3/linm HM 332 Hebe 'Marjorie' 30-40cm, 3L 3 breaks in lower third4/m2 HMB 106 Hebe 'Midsummer Beauty' 30-40cm, 3L 3 breaks in lower third5/m2 HMR 3 Heuchera 'Midnight Rose' 20-30cm, 3L Full pot5/m2 HN 11 Helleborus niger 20-30cm, 3L Full pot5/m2 Hor 42 Helleborus orientalis 20-30cm, 3L Full pot
SPEC HpA 7 Hydrangea paniculata 'Ammarin' 80-100cm, 5L 5 breaks in lower third5/m2 HPP 19 Heuchera 'Palace Purple' 30-40, 2L Full pot4/m2 Hq 40 Hydrangea quercifolia 30-40cm, 3L 3 breaks in lower third4/m2 HW 565 Hebe 'Wirimist' 30-40cm, 3L 3 breaks in lower third2/m2 Iaq 81 Ilex aquifolium 80-100cm, RB or 5L single stem, well fthrdSKU ID 0 Latin Name Scheduled Size Notes5/m2 IfV 14 Iris foetidissima 'Variegata' 30-40, 5L Full pot4/m2 LaA 14 Lavandula angustifolia 'Alba' 40-50cm, 7.5L 5 breaks in lower third, bushy4/m2 LG 205 Lavandula 'Grappenhall' 30-40cm, 3L 5 breaks in lower third, bushy4/m2 LLE 321 Lonicera pileata 'Loughgall Evergreen' 20-30cm, 3L bushy
SPEC LsC 5 Leptospermum scoparium 14L 1m clear stem 30-40cm ball top, 1/2 std TREE LtA 3 Liriodendron tulipfera 'Aureomarginata' 20–25cm girth rootballed4/m2 MaA 13 Mahonia aquifolium 'Apollo' 30-40, 3L Main leader well branched
TREE MR 6 Malus 'Rudolf' 10-12cm4/m2 PBS 97 Phormium 'Bronze Surfer' 40-60cm, 3L Minimum of 5 spears4/m2 PdA 422 Potentilla davurica 'Abbotswood' 20-30cm, 3L bushy, 3 breaks in lower third4/m2 PdE 23 Potentilla davurica 'Elizabeth' 20-30cm, 3L bushy, 3 breaks in lower third4/m2 PfR 61 Photinia x fraseri 'Red Robin' 40-60, 3L 5 strong breaks in lower third4/m2 PG 98 Potentilla 'Goldfinger' 20-30cm, 3L Bushy, 3 breaks in lower third4/m2 PS 10 Phormium 'Surfer' 40-60cm, 3L Minimum of 5 spears4/m2 PSQ 40 Pittosporum tenuifolium 'Silver Queen' 40-50cm, 3L 3 breaks in first third
CLIMBER Pt 6 Parthenocissus tricuspidata 'Veitchii' 90–120cm caned, min 2 breaks4/m2 PtSun 4 Phormium tenax 'Sundowner' 3L, 40-60cm min of 5 spears2/m2 PtYW-15 1 Phormium tenax 'Yellow Wave' 60-80cm, 15L Minimum of 7 spears, triple crown4/m2 PtYW-3 106 Phormium tenax 'Yellow Wave' 40-60cm, 3L Minimum of 5 spears
SPEC PxfR-25 2 Photinia x fraseri 'Red Robin' Half standard 25L 40–50cm ball3/m2 RFDR 31 Rosa 'Fru Dagmar Hastrop' (Red flwr) 30-40, 3L 5 breaks in lower third
SPEC RG-7.5L 5 Rosa 'Golden Wings' 1.0-1.2m, 7.5L on trellis4/m2 RGW 38 Rosa 'Golden Wings' 30-40cm, 3L 3 breaks in lower third4/m2 RMM 84 Rosa White 'Meidiland' var. 'Meicoublan' 30-40cm, 3L 3 breaks in lower third4/m2 RSS 53 Rosmarinus officinalis 'Severn Sea' 30-40cm, 3L 3 breaks in lower third
TREE SaM 15 Sorbus aria 'Majestica' 12-14cm5/m2 SaS 33 Stipa arundinacea 'Sirrocco' 30-40cm, 5L bushy, full pot4/m2 ScG 25 Spiraea x cinerea 'Grefsheim' 30-40cm, 3L 5 breaks in lower third, bushy4/m2 SjAW 32 Spiraea japonica 'Anthony Waterer' 30-40, 3L Bushy, 5 breaks in lower third4/m2 SR 57 Skimmia 'Reevesiana' 30-40cm, 3L 3 breaks in lower third4/m2 Vb 18 Verbena bonariensis 30-40cm, 3L 5 breaks in lower third4/m2 Vg 32 Viburnum globosum 'Jermyn's Globe' 30-40cm, 3L 3 breaks in lower third
plan
ting
spec
ifica
tion
3/linm
• The landscape contractor to make him/herself aware of any underground services prior to planting.
• Tree locations are subject to confirmation of engineering and foundation details. Foundations shall comply with guidelines set by structural engineering consultants, and shall accord with the current NHBC Standards 'Building near Trees' and shall accommodate immediate and future impact of tree or shrubs on buildings and their foundations.
• Any proposed substitutions, whether species, cultivar, pot size or other specification, must be approved by landscape architect prior to planting;
• Any significant layout changes necessitating revised details (such as new retaining walls casting shade on planting beds) should be reported to the landscape architect;
• All Nursery Stock to comply with BS3936 Part 1:1992 and all subsequent amendments;
• The supply and planting of trees will be in accordance with BS 8545:2014;
• Test soil in Cornus beds to ensure within range 6.1-7.0pH (acid soil). If pH is higher than 7.0 incorporate some ericaceous peat-free compost into the backfill soil of each tree pit, and use as a mulch;
• All Landscape operations to comply with BS4428:1989 and all subsequent amendments;
• Bark mulch to be dark brown mixed conifer bark of particle size 8-35mm and pH range 5.0-7.0 to BS PAS 100:2005; mulch to be laid to 75mm (settled) depth;
• Watering to continue as required throughout first growing season following planting;
• Wildflower grass seed to be Germinal Seeds (formerly British Seed Houses) MG8 Floodplain/Water Meadow sown at 5g/m2 or WFG8 Butterfly and Honey Bee sown at 5g/m2 as shown
• All planting beds and pits to receive compost during cultivations at a rate of 1m3 to 20m2 and slow release fertiliser (e.g. Ficote 140) at rate of 25g/plant (no fertiliser to tree pits); beds to be thoroughly watered following planting and before receiving 75mm (settled) depth bark mulch; watering to continue as required throughout first growing season following planting.
Protection of existing trees and hedges to be retained• Prior to construction on site, protective fencing shall be erected around each tree or group at a minimum radius from the trunk of the tree of the canopy extent plus 10% (whichever is the greater). No soil, spoil or other material shall be deposited within the fenced areas;
• Underground services to be routed to avoid fenced areas;
• No burning to take place within 10m of the furthest extent of the canopy of trees to be retained on site or on land adjoining;
• The fence shall be kept in constant repair throughout the development work;
• The protective fencing shall be retained in position until completion of the development, when it shall be removed only with the written consent of the planning authority;
• In areas where fencing is specified in construction areas, fence to be retained in place until construction works take place underneath trees. Fencing to be moved on daily basis and replaced at end of each working day. Methdology to be supplied for hand digging underneath roots and installation of load bearing membrane;
• The fence shall be at least 2.4 metres high, comprising of a scaffolding framework, as in 8.2.2 of BS 5837 (2012), supporting a minimum of 200mm exterior grade ply or other approved robust man-made boards as shown in BS 5837 (2012), Figure 5
• All rootballed trees to be anchored underground with Greenleaf Rootball Fixing System and planted with Greenleaf ‘Root Rain Urban’ watering pipes, fitted according to manufacturer’s instructions;
• Tree pits to be excavated to minimum 1m x 1m x depth of rootball. In sloping ground, maintain horizontal bases and vertical sides with no less than minimum depth throughout. Break up bottoms of pits to a depth of 150mm and scarify sides. Pits to be backfilled with a previously prepared mixture of 90% topsoil, together with 10% peat free planting compost. No fertilisers should be applied unless specific deficiencies have been identified by soil testing and the fertiliser addresses the deficiency.
• Bareroot/containerised trees to be staked with short double stakes a maximum of one quarter the height of the tree above ground, and fixed with Greenleaf biodegradable hessian ties;
• Trees in grass to be planted in 1.8m diameter mulched bed with neat and vertical edges cut with half moon edging tool; bed to be retained weed free for the first three years following planting;
• All avenue trees to be selected to be of similar size, form and habit;
• Grass areas in front gardens and other areas to be turfed; grass areas under trees to be seeded; back gardens to be stone picked and left as bare soil; and
• Garden hedges to be planted in single rows along centreline of 0.8m width bed.
Preparatory work• The protection and provision of topsoil and subsoil for planting areas should accord with the Construction Code for the Sustainable Use of Soils on Construction Sites (DEFRA, 2009), BS 38832:2007 and BS 8545:2014;
• For all tree pits and planting areas, percolation tests must be carried out to ensure subsoil is free draining. Where impeded drainage is identified, suitable provision is to be made (to CA approval) by for example removal or ripping of compacted soil, in order to remedy poor drainage prior to planting or digging of tree pits;
• Great care must be taken to preserve existing soil quality and integrity. Topsoil and subsoil are to be protected from vehicle tracking and other compaction by temporary removal and storage or by using ground protection in line with the Construction Code and BS above.
• Any soil found to be compacted following construction is to be ameliorated by ripping. In addition, topsoil and subsoil must not be mixed and works involving soil removal or cultivation must only take place during suitable weather conditions.
• All planting and grass areas to be cultivated and spread with a good quality topsoil to BS 3822 to a depth of not less than 150mm (grass areas), 400mm (planting beds); topsoil allowed to settle prior to planting or turfing; turf laid to all frontages and maintained appropriate to season;
• Rear gardens to be cultivated/stone picked and left for planting by occupier, except where shown;
• All landscape works to be completed prior to occupation of each dwelling;
spec
ifica
tion
note
s
Ordnance Survey (c) Crown Copyright 2014. All rights reserved. Licence number 100022432
catherine etchell associateslandscape architecture • recreation planning
t: 01874 636903 • f: 0871 9004460 • e: [email protected] y Bedw • Libanus • Brecon • LD3 8NN
scale • 1:250 at A0
date • March 2015
drawn • CE
drawing number • 306.01/01
revision • D
job title drawing title
client
Greenmeadow Way, Cwmbran
Taylor Wimpey
Planting PlanSheet 1 of 2
Revision D September 2015: Revised layoutRevision C July 2015: Revised layoutRevision B May 2015: Revised layout
306.
01 C
wm
bran
MG8 within basin
underground storage tanks
underground storage tanks
1-ARH
Foot
path
Lin
k
39
10 1112
13
14
15
16
17
1819
20
30 31
3233
3435
36
37
38
40
41
42
4344 45 46
4748
495051
66
67
68
69
70
71
72
73
74
7576
77
78
79
80
82
83
84
8586
87
88
8990
9192
93
95
969798
99100101
102103
104105106107
108109110
111112
114
115
116
117
118119
120
121
122
123
124125126
127128
129130
131
132
139
148
202-207
SHED
SHED
SHED
SHED
SHED
SHED
6261
6059
58
5756
55
6564
63
133
134135136137138
81
Footpath Link
Footpath Link
Footpath Link
SHED
1-LtA
Mix in groups of 2-3no.:10-CSP10-Cxp16-LG4-Vb
1-Fj
9-HM
16-HAG
5-CaSV
5-CPC
9-HMB
5-HMB
2-RGW
7-SjAW
5-Vg
14-HLM
10-HLM
11-Vg
5-CaSV
9-Vg
10-Hor
7-SjAW
1-HpA
1-HpA
1-HpA 1-HpA
1-HpA
Mix in groups of 2-3no.:12-Ctr7-RMM7-RSS3-Vb
3-PSQ
Mix in groups of 2-3no.:7-Ctr4-RMM4-RSS1-Vb
5-PSQ
Mix in groups of 2-3no.:8-Ctr5-RMM5-RSS2-Vb
1-RG-7.5L
1-RG-7.5L
1-RG-7.5L
1-RG-7.5L
11-HMB
16-HMB
5-HL
2-PxfR-25
17-HMB
10-Ctr
18-Ctr
19-Ctr
1-HpA
3-Aa
12-HL
11-HL
5-HL
5-HL7-RGW
3-RGW
8-PdE
3-PdE
3-HMB
5-RFDR
5-RFDR
9-CAP
10-HMB
9-LG
9-LG
6-Cxp6-Cxp
6-SjAW
3-RSS
5-RFDR
6-PfR
13-HW
15-HW
6-RGW
5-Hor
5-PdE10-CaSV
5-CaSV
8-HMB
8-Ctr
7-HL
8-Ctr
7-Ctr
6-HMB
1-CMW
7-PSQ
3-PfR
12-Ctr
6-ScG
10-HW8-LG
6-LG
9-LG
12-SjAW
1-Fj
1-Fj Mix in groups of 3-4no:7-Aa7-EGB
Mix in groups of 3-4no:9-Aa9-EGB
10-HW
5-CAP
Mix in groups of 3-4no:5-LG5-RMM
Mix in groups of 3-4no:6-LG6-RMM
7-RSS
Mix in groups of 3-4no:7-LG7-RMM
Mix in groups of 3-4no:7-LG
7-RMM
5-RSS
2-PSQ
3-PfR
3-RFDR
4-RFDR
3-RFDR
4-CAP
4-EGB
4-CaSV26-HW
6-PfR
5-CaSV
6-Hq
7-PdE
14-HW
4-Aa
6-SR
8-SR
3-PfR
9-HM
8-HM7-PfR
11-ScG
7-HMB
13-SR8-HLM8-PG
1-Fj
1-Fj
12-PBS
12-PBS
16-PBS
7-Vg
6-PBS
Mix in groups of 3-4no:10-HAG10-SaS
5-HAG
5-HAG
23-HAG
18-PG
11-PG
47-PdA
23-PdA
45-PdA
7-HW
31-HW
24-HW
14-HW
104-HW
41-HW
58-HW
123-HW
35-CsK
28-CsK
34-CsK
60-CsK
4-CsK
34-CsK
60-CsK
48-CsK
19-CsK
11-CsK
57-CsK
41-CsK
6-Cb
15-CaSV
4-EA
20-HM8-Cb
1-MR
23-Cb
3-Ctr
9-Ctr
11-BSil
11-BSil
9-CAP
9-HAG
1-MR
8-CaSV
13-MaA
14-CAP
10-HL
3-HMR
3-Hq
6-HM6-HM
5-CaSV
9-LaA
Mix in groups of 2-3no.:9-Cxp7-LG1-Vb
Mix in groups of 2-3no.:9-Cxp7-LG1-Vb
7-CAP
4-CPC
14-HM10-HM
12-CPC
18-CaSV
15-EQ47-Cb47-Cb
32-HM
Mix in groups of 3-4no:9-LG9-RMM
1-LtA
19-CPC
14-EQ
22-Ctr
8-Aa
1-CMW
Mix in groups of 3-4no:9-LG9-RMM
5-CSP
5-CSP
13-RSS
22-CSP
14-EQ
15-CPC
13-CAP
11-PfR
Mix in groups of 3-4no:7-Aa7-EGB
5-Ctr
Mix in groups of 3-4no:7-LG7-RMM
21-EA
4-Hq
9-PBS
5-HBC
13-EQ
5-CPC
14-Cb
1-LtA
1-CbFF
1-CbFF
1-CbFF
1-CbFF
2-CbFF
1-CbFF
1-CbFF 1-CbFF
1-CbFF
1-CbFF
2-CbFF1-CbFF
1-CbFF
2-CbFF
1-CbFF
1-CbFF
1-CbFF
1-Pt1-Pt
1-Pt
1-Pt
1-CIS
1-CIS1-CIS
36-Cb
26-Cb
26-Cb
28-Cb45-Cb
40-Cb 22-Cb
34-Cb
44-Cb
27-Cb
32-Cb45-Cb
32-Cb
13-Cb22-Cb
9-Cb
14-Cb
29-Cb
21-HM
14-HM
14-HM6-HM
14-EA 15-EA17-EA
11-EA11-EA
22-Cb
14-Cb
20-Cb
5-EA
26-EA
23-Cb
1-MR
1-Asp
1-Asp
1-Asp
1-Asp
1-CMW1-Asp
1-MR
1-CMW
1-CbFF
1-CMW
1-CbFF
1-CbFF7-HW
11-SaS
1-Asp
1-Asp
306.
01 C
wm
bran
catherine etchell associateslandscape architecture • recreation planning
t: 01874 636903 • f: 0871 9004460 • e: [email protected] y Bedw • Libanus • Brecon • LD3 8NN
scale • 1:250 at A0
date • March 2015
drawn • CE
drawing number • 306.01/02
revision • D
job title drawing title
client
Greenmeadow Way, Cwmbran
Taylor Wimpey
Planting PlanSheet 2 of 2
Revision D September 2015: Revised layoutRevision C July 2015: Revised layoutRevision B May 2015: Revised layout
1-Asp
Future Access to Remaining Phases
Future Access to Remaining Phases
Footpath Link
92
93
9495
96
1-HpA
Mix in groups of 2-3no.:8-Ctr5-RMM5-RSS2-Vb
1-RG-7.5L
5-RFDR9-CAP
9-LG
6-Cxp
6-SjAW
4-PtSun
11-HL
6-RFDR
9-LG
3-RSS
3-RSS
11-SaS