specification - huawei power solutions modules.pdf · rtn(+) pdc2500s12-ce front view pac2000s12-ce...
TRANSCRIPT
SERVER POWER SERIES
Blade Server Power Supply Series
Introduction
Blade server power supply series contains AC-DC and DC-DC three products, including 2000W, 2500W and 3000W power, support N+1 redundant, hot swap, PMBus communication and relevant protection. Surge protection meet IEC61000-4-5 and ITU-TK.21 standard. Be suitable for servers, storage, advanced workstations, routers, network switches, telecommunications equipment and so on.
Model Parameter Notes & Conditions
Output characteristics
Output voltage range ALL 12.0 - 12.8 V -
Output power
PAC2000S12-CE 2000 WVin=90 - 200 VAC; Pomax=800WVin=200 - 220 VAC; Pomax=1800WVin=220 - 264 VAC; Pomax=2000W
PAC3000S12-CE 3000 WVin=90 - 175 VAC; Pomax=1200WVin=175 - 200 VAC; Pomax=2500WVin=200 - 264 VAC; Pomax=3000W
PDC2500S12-CE 2500 WVin=38 - 40 VDC; Pomax=2200WVin=40 - 72 VDC; Pomax=2500W
Output line regulation ALL 1%Vo Vin=90 - 264 VAC; Po=Max
Output load regulation ALL 1.2%Vo Vin=220 VAC; Po=0 - Max
Output ripple and noise (PK-PK) ALL 150mV Oscilloscope bandwidth: 20 MHz
Input characteristics
Operating input voltagePAC2000S12-CEPAC3000S12-CE
90 - 264 VAC@50/60Hz -
PDC2500S12-CE 38.4 - 72V
Maximum input current
PAC2000S12-CE 10A Vin=220 VAC; Po=2000W
PAC3000S12-CE 16A Vin=220 VAC; Po=3000W
PDC2500S12-CE 80A Vin=38 - 72V; Po=2500W
Power factorPAC2000S12-CEPAC3000S12-CE
0.98 Vin=220 VAC; Po=Max
Protection characteristics
Input OVP
PAC2000S12-CEPAC3000S12-CE
Turn on: 275V ACTurn off: 280V AC
Hysteresis: 5.0V
PDC2500S12-CETurn on: 77VTurn off: 82V
Hysteresis: 2.0V
Input UVP
PAC2000S12-CEPAC3000S12-CE
Turn on: 89V ACTurn off: 84V AC
Hysteresis: 5.0V
PDC2500S12-CETurn on: 36VTurn off: 34V
Hysteresis: 2.0V
Output OVP ALL 15V Latch-off
Over current Protection
PAC2000S12-CE 170A - 200A
Latch-offPAC3000S12-CE 256A - 300A
PDC2500S12-CE 213A - 250A
Over temperature Protection PAC3000S12-CE - Self-recovery
Absolute maximum ratings
Operating ambient temperature
PAC2000S12-CE -5 - 60ºC
-PAC3000S12-CE -5 - 50ºC
PDC2500S12-CE 0 - 50ºC
Storage temperature PAC3000S12-CE -40 - 85ºC -
Other characteristics
PMBus communication ALLInput voltage/current/power
Output voltage/current/powerOutput OVP/UVP alarm
-
Surge
PAC2000S12-CELine to earth: ±2.5kVLine to line: ±2.5kV
IEC61000-4-5
PAC3000S12-CELine to earth: ±6kVLine to line: ±6kV
IEC61000-4-5/ITU-TK.21
PDC2500S12-CELine to earth: ±4kVLine to line: ±2.5kV
IEC61000-4-5
Mean time between failures (MTBF)
ALL 0.5 million hoursTelcordia SR332, Vin=220VAC,100% load, TA=25ºC
Specification
Features
• Over current protection • Short circuit protection • Output overvoltage protection • Over temperature protection • PMBus 1.2 communication
protocol • Suitable for the TT, TN, IT power
supply system * • N+N, N+M redundant backup • Multi modules parallel
*PDC2500S12-CE without this function
42
SERVER POWER SERIES
Model Input Voltage Output Voltage Output Current Output Power Efficiency
PAC2000S12-CE 90 - 264 Vac 12V 162.6A 2000W 94.5%
PAC3000S12-CE 90 - 264 Vac 12V 244A 3000W 94.5%
PDC2500S12-CE 38.4 - 72V 12V 203.3A 2500W 94.0%
Model Selector
Pin Definition Description Pin Definition Description
P1~P6 12V Output: 12V DC D2 PRESENT Power supply present (lagging pin)
P7~P12 GND Power GND A3 DCOK Indicator whether the DC output voltage is OK
A1 A0 Address0 B3 ACOK Indicator whether the AC output voltage is OK
B1 A1 Address1 C3 PS_INTERRUPT Power supply interruption signal
C1 A2 Address2 D3 PSON Power supply on/off control signal
D1 PS_KILL Power supply kill A4 NA -
A2 SCL PMBus clock signal B4 I_Monitor 12V DC load sharing
B2 SDA PMBus data signal C4 Sense+ 12V DC remote sense+
C2 GND Signal GND D4 Sense- 12V DC remote sense-
Tolerances±0.5[0.02in.] (≤63[2.48])±1.0[0.04in.] (>63[2.48])
Pin definition of output socket:
Mechanical Diagram
Unit: mm [in.]
Input connector:3000W --- IEC 60320 C202000W --- IEC 60320 C142500W --- M6 double OT terminal
Output socket: Tyco (1-6450831-8)Mating connector: Tyco (1-6450861-3)
DCBA
1 2 3 4
P1 P5 P9P2 P6 P10P3 P7 P11P4 P8 P12
Output Socket
303.5 [11.95]
3.8
[0.1
5]
14.6
[0.5
7]
10.0 [0.39]
40.5
[1.9
5]
Side View
126.
0 [4
.96]
97.5
[3.8
4]11
.5 [0
.45]
276.8 [10.90]
17.0
[0.6
7]
Top View
Back View
NEG(-)
RTN(+)
PDC2500S12-CE
Front View
PAC2000S12-CE & PAC3000S12-CE
PAC2000S12-CEinput connector
43
SERVER POWER SERIES
Rack Server Power Supply Series
Introduction
Rack server power supply series contains 750W and 460W two power levels, support N+1 redundant, hot swap, high voltage DC input, PMBus communication and relevant protection. Surge protection meet IEC61000-4-5 and ITU-TK.21 standard. Be suitable for servers, storage, advanced workstations, routers, network switches, telecommunications equipment and so on.
Model Parameter Notes & Conditions
Output characteristics
Output voltage range ALL11.85 - 12.45 V
11.4 - 12.6 V@12V StandbyVin=90 - 264 VAC; Po=Max Vin=192 - 288 VDC; Po=Max
Output power
PAC750D1212-CE 750WVin=90 - 264 VAC; Pomax=750WVin=192 - 288 VDC; Pomax=750W
PAC460D1212-CE 460WVin=90 - 264 VAC; Pomax=460WVin=192 - 288 VDC; Pomax=460W
Output ripple and noise (PK-PK) ALL 120mV Oscilloscope bandwidth: 20 MHz
Input characteristics
Operating input voltage ALL 90 - 264 VAC@50/60Hz;
-192- 288 VDC
Maximum input currentPAC750D1212-CE 10A Vin=230 VAC; Po=750W
PAC460D1212-CE 6A Vin=230 VAC; Po=460W
Power factor ALL 0.97 Vin=230 VAC; Po=Max
Protection characteristics
Input UVP ALL Turn on: 89V ACTurn off: 84V AC
Hysteresis: 5.0V
Input OVP ALL Turn on: 275V ACTurn off: 280V AC
Hysteresis: 5.0V
Output OVP ALL 15V Latch-off
Over current Protection
PAC750D1212-CE73A - 93A
2.5 - 3 A@12V Standby Latch-off
PAC460D1212-CE43A - 53A
2.5 - 3 A @12V Standby
Over temperature Protection ALL - Self-recovery
Absolute maximum ratings
Operating ambient temperature ALL -5 - 55ºC -
Storage temperature ALL -40 - 85ºC -
Other characteristics
PMBus communication ALLInput voltage/current/power
Output voltage/current/powerOutput OVP/UVP alarm
-
Surge ALLLine to earth: ±2.5 kVLine to line: ±2.5kV
IEC61000-4-5
Mean time between failures (MTBF)
ALL 0.5 million hoursTelcordia SR332, Vin=220VAC,100% load, TA=25ºC
Specification
Features
• Over current protection • Short circuit protection • Output overvoltage protection • Over temperature protection • PMBus 1.2 communication
protocol • Suitable for the TT, TN, IT power
supply system • N+1 redundant backup (N≤5) • Multi modules parallel
44
SERVER POWER SERIES
Model Input Voltage Output Voltage Output Current Output Power Efficiency
PAC750D1212-CE90 - 264 Vac
192V-288V dc 12V/12V 62.5A/2A 750W 94%
PAC460D1212-CE90 - 264 Vac
192V-288V dc 12V/12V 38.3A/2A 460W 94%
Model Selector
Pin Definition Description Pin Definition Description
01~13, 52~64 12V Main output: 12 V DC 32 SCL I2C clock signal
14~26, 39~51 GND 12V&12VSB Power GND 33 PSON Power supply on/off control signal
27 A2 Address2 34 I-MON 12 V DC load sharing
28 A1 Address1 35 PSOK Indicator whether the main output voltage is OK
29 A0 Address0 36 PRESENT Power supply module present (short pin)
30 GND I2C GND 37 12VSB Standby output: 12 V DC
31 SDA I2C data signal 38 PS_INTERRUPT I2C interruption signal
Tolerances±0.5[0.02in.] (≤63[2.48])±1.0[0.04in.] (>63[2.48])
Pin definition of output gold finger:
Mechanical Diagram
Unit: mm [in.]
Input connector: IEC 60320 C14Gold finger mating connector: FCI (10075664-003LF)
Top View
194.2 [7.64]
227.0 [8.94]
83.5
[3.2
9]1.
4 [0
.06]11.1 [0.44]
Barcode
Product nameplate
Side View
31.0 [1.22] 190.5 [7.50]
196.5 [7.74]
8.3
[0.3
3]
1.6
[0.0
6]
14.0
[0.5
5]12
.5 [0
.49]86.4 [3.40]
38.4
[1.5
1]
40.5
[1.5
9]
Front View
Back View
Output Gold Finger
TOP
BOTTOM
33
32
38
27
39
26
51
14
52
13
64
1
45
COMMUNICATION CUSTOM POWER SERIES
Features
• Over current protection • Short circuit protection • Output overvoltage protection • Over temperature protection • Suitable for the TT, TN, IT power
supply system
Model Parameter Notes & Conditions
Output characteristics
Output voltage range PAC440D5412-ON-51.41 ~ -54.59V11.64 ~ 12.36V
-
Output power PAC440D5412-ON-53.5V@380W
12V@60W-
Output line regulation PAC440D5412-ON 1%Vo Vin=90 - 264 VAC; Po=440W
Output load regulation PAC440D5412-ON 3%Vo Vin=220 VAC; Po=0 - 440W
Output ripple and noise (PK-PK) PAC440D5412-ON-53.5V@500mV
12V@600mVOscilloscope bandwidth: 20 MHz
Input characteristics
Operating input voltage PAC440D5412-ON90 - 290
VAC@50/60Hz-
Maximum input current PAC440D5412-ON 5.3A Vin=220 VAC; Po=440W
Power factor PAC440D5412-ON 0.98 Vin=220 VAC; Po=440W
Protection characteristics
Input UVP PAC440D5412-ONTurn on: 90V ACTurn off: 85V AC
Hysteresis: 5.0V
Output OVP PAC440D5412-ON-57 ~ -60V13.5 ~ 16V
Hiccup
Over current Protection PAC440D5412-ON-53.5V@8 - 10A12V@6 - 7.5A
Hiccup
Over temperature Protection PAC440D5412-ON 75ºC Self-recovery
Absolute maximum ratings
Operating ambient temperature PAC440D5412-ON -25 - 55ºC -
Storage temperature PAC440D5412-ON -40 - 70ºC -
Other characteristics
Surge PAC440D5412-ONLine to earth: ±6 kVLine to line: ±6 kV
IEC61000-4-5/ITU-TK.21
Mean time between failures (MTBF) PAC440D5412-ON 0.25 million hoursTelcordia SR332, Vin=220VAC, 100% load, TA=25ºC
Specification
PAC440D5412-ON Power Module
Introduction
PAC440D5412O-ON Open frame AC-DC POE power module has 90 to 290Vac wide input voltage, -53V and 12V dual isolated outputs, total rating output power 440W (12V/60W; -53Vdc /380W). The module is environmental air cooling. Surge protection meet IEC61000-4-5 and ITU-TK.21 standard. Be suitable for switches, routers, access equipments and so on, that need dual power supply of 12V and 48V.
46
COMMUNICATION CUSTOM POWER SERIES
Model Input Voltage Output Voltage Output Current Output Power Efficiency
PAC440D5412-ON 90 - 290 Vac -53.5V/12V 7.2A/5A 440W 91.5%
Model Selector
Tolerance190.0±0.5[7.48±0.02in]90.0±0.5[3.54±0.02in]36.0±1.0[1.42±0.04in]
Pin definition of output connector:
Pin Definition Colour Description
1 -53V Blue Output: -53 V DC
2 -53V Blue Output: -53 V DC
3 NC - Keeping float
4 alarm Green AC input power off alarm (H:OK; L:abnormal)
5 +12V Red Output: 12 V DC
6 +12V Red Output: 12 V DC
7 +12V Red Output: 12 V DC
8 RTN(-53V) Yellow RTN(-53V)
9 RTN(-53V) Yellow RTN(-53V)
10 NC - Keeping float
11 POWER_GOOD Gray Indicator whether the 12V/-53V output voltage is OK (H:OK; L:abnormal)
12 12V_GND Black 12V GND
13 12V_GND Black 12V GND
14 12V_GND Black 12V GND
Mechanical Diagram
Unit: mm [in.]
90.0
[3.5
4]
Top View
190.0 [7.48]
36.0
[1.4
2]
Side View
Side View
1 2 3 4 5 6 7
8 9 10 11 12 13 14
Output connector: Molex (39-01-2145)
Input connector: Senda Zhejiang(SD W50801-3A-HW)
2.40
N
L
4.5
47
COMMUNICATION CUSTOM POWER SERIES
Model Parameter Notes & Conditions
Output characteristics
Output voltage range PAC500D5412-CE-51.89 ~ -55.11V
11.4 ~ 12.6V-
Output power PAC500D5412-CE-53.5V@380W
12V@120W-
Output line regulation PAC500D5412-CE 1%Vo Vin=90 - 264 VAC; Po=500W
Output load regulation PAC500D5412-CE 3%Vo Vin=220 VAC; Po=0 - 500W
Output ripple and noise (PK-PK) PAC500D5412-CE-53.5V@500mV
12V@200mVOscilloscope bandwidth: 20 MHz
Input characteristics
Operating input voltage PAC500D5412-CE90 - 290
VAC@50/60Hz-
Maximum input current PAC500D5412-CE 6.3A Vin=220 VAC; Po=500W
Power factor PAC500D5412-CE 0.98 Vin=220 VAC; Po=500W
Protection characteristics
Output OVP PAC500D5412-CE-57 ~ -60 V13.4 ~ 15V
Latch off
Over current Protection PAC500D5412-CE-53.5V@8 - 10A12V@12 - 16A
Hiccup
Over temperature Protection PAC500D5412-CE 70ºC Self-recovery
Absolute maximum ratings
Operating ambient temperature PAC500D5412-CE -25 - 55ºC -
Storage temperature PAC500D5412-CE -40 - 85ºC -
Other characteristics
I2C communication PAC500D5412-CEInput voltage/current/power
Output voltage/current/powerOutput OVP/UVP alarm
-
Surge PAC500D5412-CELine to earth: ±6 kVLine to line: ±6 kV
IEC61000-4-5/ITU-TK.21
Mean time between failures (MTBF) PAC500D5412-CE 0.25 million hoursTelcordia SR332, Vin=220VAC, 100% load, TA=25ºC
Specification
PAC500D5412-CE Power Module
Introduction
PAC500D5412-CE cassette AC-DC POE power module has 90 to 290Vac wide input voltage, -53V and 12V dual isolated outputs, total rating output power 500W (12V/120W; -53Vdc /380W). The module is configured with fan for cooling through a back-to-front airflow. Surge protection meet IEC61000-4-5 and ITU-TK.21 standard. Be suitable for switches, routers, access equipments and so on, that need dual power supply of 12V and 48V.
Features
• Over current protection • Short circuit protection • Output overvoltage protection • Over temperature protection • I2C communication protocol • Hot swap • Suitable for the TT, TN, IT power
supply system • 1+1 redundant backup
48
COMMUNICATION CUSTOM POWER SERIES
Pin definition of output socket:
Pin Definition Description
P3 12V+12V output
P4 12VGND
D5 I2C-SDA I2C data signal
D6 I2C-SCL I2C clock signal
D4 3.3V3.3V power supply from the main board, giving I2C chip
power supply of the module
C4 A0 I2C E2PROOM address0
C5 A1 I2C E2PROOM address1
C6 PRESENTTo indicate to the system that the module is inserted in the power bay. This pin has been shorted to the 12VGND in the
module
D3 PG-12VIndicator whether the 12V output voltage is OK, using
12VGND (H:OK, L:abnormal)
B4 WPWrite Protect: this pin should connected to 3.3V power
supply from the main board, using 12VGND
B6 A2 I2C E2PROOM address2
A3 SHARE-48V48V output current sharing signal, when two modules
working in current sharing mode, this pin of each module should connect together
A4 PG-48VIndicator whether the 48V output voltage is OK, using
12VGND (H:OK, L:abnormal)
A5 PSKILLHot swap signal, short pin, when this pin connect to the
12VGND by the back board, the module be enable
P2 48V-48V output
P1 48V+(RTN)
Tolerances±0.5[0.02in.] (≤63[2.48])±1.0[0.04in.] (>63[2.48])
Input connector: IEC 60320 C14Output socket: JONHON (DP2TJW0424-007)Mating connector: JONHON (DP2ZJB0424-001)
Mechanical Diagram
Unit: mm [in.]
FC-3-3B
Top View Front View
43
.2[1
.70]
19
.9[0
.78]
INPUT
OUTPUT
100-240Vac 50/60Hz 7-3.5A
18.0 [0.71]
15-M3X6
9.3 [0.37]
39
.8[1
.57]
195.4 [7.69]
Side View Back View
90.0 [3.54]57.2 [2.25]43.3 [1.70]
9.0 [0.35]
Output Socket
HAHAPAPAPAPA
DCBA
ROW SPOW ER
E1 P1 P2 P3 P4 E2
POW ERSIGNAL1 2 3 4 5 6
UTSR
UTSR
UTSR
UTSR
UTSR
UTSR
Model Input Voltage Output Voltage Output Current Output Power Efficiency
PAC500D5412-CE 90 - 264 Vac -53.5V/12V 7.1A/10A 500W 89.0%
Model Selector
49
COMMUNICATION CUSTOM POWER SERIES
Features
• Over current protection • Short circuit protection • Output overvoltage protection • Over temperature protection • I2C communication protocol • Hot swap • Suitable for the TT, TN, IT power
supply system • 1+1 redundant backup
PAC1000D5403-CN Power Module
Introduction
PAC1000D5403-CN cassette AC-DC power module has 90 to 290Vac wide input voltage, -53.5V and 3.3V dual isolated outputs, total rating output power 1000W (53.5V/900W; 3.3Vdc /82.5W). The module is environmental air cooling. The module is suitable for the application of transport network.
Model Parameter Notes & Conditions
Output characteristics
Output voltage range PAC1000D5403-CN50.8 ~ 56.2V3.23 - 3.57 V
-
Output power [email protected]@82.5W
-
Output line regulation PAC1000D5403-CN53.5V@2%[email protected]%
Vin=90 - 264 VAC; Po=1000W
Output load regulation PAC1000D5403-CN53.5V@2%[email protected]%
Vin=220 VAC; Po=0 - 1000W
Output ripple and noise (PK-PK) [email protected]@100mV
Oscilloscope bandwidth: 20 MHz
Input characteristics
Operating input voltage PAC1000D5403-CN90 - 290
VAC@50/60Hz-
Maximum input current PAC1000D5403-CN 9A Vin=220 VAC; Po=1000W
Power factor PAC1000D5403-CN 0.98 Vin=220 VAC; Po=1000W
Protection characteristics
Input OVP PAC1000D5403-CNTurn on: 290V ACTurn off: 300V AC
Hysteresis: 5.0V
Input UVP PAC1000D5403-CNTurn on: 90V ACTurn off: 85V AC
Hysteresis: 5.0V
Output OVP PAC1000D5403-CN58.5 ~ 61.5V
3.8 ~ [email protected]@Hiccup
Over current Protection [email protected] - 21.8A
3.3V@33 - 42AHiccup
Over temperature Protection PAC1000D5403-CN - Self-recovery
Absolute maximum ratings
Operating ambient temperature PAC1000D5403-CN -5 - 55ºC -
Storage temperature PAC1000D5403-CN -40 - 85ºC -
Other characteristics
I2C communication PAC1000D5403-CN
Output voltage; Output OVP alarm;
OTP alarm; Electronic label
-
Impulse current PAC1000D5403-CN DM: 3kA, CM: 5kA -
Surge PAC1000D5403-CNLine to earth: ±6 kVLine to line: ±6 kV
IEC61000-4-5/ITU-TK.21
Specification
50
COMMUNICATION CUSTOM POWER SERIES
Model Input Voltage Output Voltage Output Current Output Power Efficiency
PAC1000D5403-CN 90 - 290 Vac 53.5V/3.3V 16.8A/24.3A 1000W 93.0%
Model Selector
Mechanical Diagram
Unit: mm [in.]
183.
80 [7
.24]
49.9
5 [1
.97]
18.9
5 [0
.75]
2-5.
20 [0
.20] 186.15 [7.33]
196.55 [7.74]
21.75 [0.86]
208.90 [8.22]
Top View
Front View
PWR
OFF
~100-120V;50/60Hz;8A~200-240V;50/60Hz;5A
ON
API
U
20
.32
[0.8
0]
32
.87
[1.2
9] 70.0 [2.76]
193.80 [7.63]
40.0 [1.57]
41
.83
[1.6
5]
183.8 [7.24]
5.0 [0.20]
Back View
173.40 [6.83]
193.80 [7.63]
Input connector: IEC 60320 C14Output socket: J1—STARCONN (091A01-8A00A) J2, J3, J4----FCI (10073379-001LF)
39.7
4 [1
.56]
15.9
[0.6
3]
0.6
[0.0
2]
Side View
VO3 GND RTN VO1
J1
J2 J3 J4
EDCBA
6 5 4 3 2 1
Output Socket
Tolerances±0.5[0.02in.] (≤63[2.48])±1.0[0.04in.] (>63[2.48])
Pin definition of J1:
Pin Definition Description
A1 PRESENT To indicate to the system that the module is inserted in the power bay. This pin has been shorted to the GND in the module
A2 - A6 NA -
B1 - B6 NA -
C1 - C6 GND 3.3V output GND
D1 - D6 NA -
E1 ALARM AC input power off alarm signal (H:abnormal, L:OK)
E2 I2C-SCL I2C clock signal
E3 I2C-SDA I2C data signal
E4 SLOT ADDRESS 1 Slot address and I2C communication address; A3: A2: A1000: The module in slot A010: The module in slot B
E5 SLOT ADDRESS 2
E6 SLOT ADDRESS 3
51
COMMUNICATION CUSTOM POWER SERIES
PAC2700S54-CB Power Module
Introduction
PAC2700S54-CB cassette AC-DC power module has 90 to 290Vac wide input voltage and single output of -53.5V. The module is configured with fan for cooling through a front-to-back airflow, support CAN communication and multi modules current sharing. Surge protection meet IEC61000-4-5 and ITU-TK.21 standard. Be suitable for switches, blade server, routers, transport network equipments and so on.
Model Parameter Notes & Conditions
Output characteristics
Output voltage range PAC2700S54-CB -53.5V -
Output power PAC2700S54-CB2700W
≤1200WVin=176 - 290V ACVin=90 - 175V AC
Output line regulation PAC2700S54-CB 1%Vo Vin=90 - 290 VAC; Po=2700W
Output load regulation PAC2700S54-CB 1%Vo Vin=220 VAC; Po=0 - 2700W
Output ripple and noise (PK-PK) PAC2700S54-CB 300mV Oscilloscope bandwidth: 20 MHz
Input characteristics
Operating input voltage PAC2700S54-CB 90 - 290 VAC@50/60Hz -
Maximum input current PAC2700S54-CB 18.5A Vin=220 VAC; Po=2700W
Power factor PAC2700S54-CB 0.98 Vin=220 VAC; Po=2700W
Protection characteristics
Input OVP PAC2700S54-CBTurn on: 290V ACTurn off: 300V AC
Hysteresis: 10.0V
Input UVP PAC2700S54-CBTurn on: 90V ACTurn off: 80V AC
Hysteresis: 10.0V
Output OVP PAC2700S54-CB 58.5 - 60.5V Latch-off
Over current Protection PAC2700S54-CB
Iomax=61A@Vo=40 - 53.5V;Iomax=55A@Vout=30 - 40V;Iomax=35A@Vout=17 - 30V;Iomax=25A@Vout=0 - 17V;
Hiccup: power on-off repeatedly
Over temperature Protection PAC2700S54-CB - Self-recovery
Absolute maximum ratings
Operating ambient temperature PAC2700S54-CB -25 - 55ºC -
Storage temperature PAC2700S54-CB -40 - 70ºC -
Other characteristics
CAN communication PAC2700S54-CBInput voltage/current/power
Output voltage/current/powerOutput OVP/UVP alarm
-
Surge PAC2700S54-CBLine to earth: ±6kVLine to line: ±6kV
IEC61000-4-5/ITU-TK.21
Mean time between failures (MTBF) PAC2700S54-CB 0.45 million hoursTelcordia SR332, Vin=220VAC, 100% load, TA=25ºC
Specification
Features
• Over current protection • Short circuit protection • Output overvoltage protection • Over temperature protection • CAN communication protocol • Suitable for the TT, TN, IT power
supply system • N+N, N+M redundant backup
52
COMMUNICATION CUSTOM POWER SERIES
Model Input Voltage Output Voltage Output Current Output Power Efficiency
PAC2700S54-CB 90 - 290 Vac -53.5V 50.5A 2700W 95.5%
Model Selector
Mechanical Diagram
Unit: mm [in.]
Front View
Input
PAC-2700WA
Output Alarm
Back View
8.9 [0.35]11.9 [0.47]
12.8 [0.50]
5.7
[0.2
2]
25.9
[1.0
2]
10.5
[0.4
1]
9.9 [0.39]
19.4 [0.76]
30.3 [1.19]
20-M2_5X8 7-M3X6 13.0 [0.51]
104.
8 [4
.13]
5.9 [0.23]
14.7 [0.58]470.9 [18.54]
425.3 [16.74]
TOP
Top View5.
7 [0
.22]
4.7
[0.1
8]12
.5 [0
.49]
30.6
[1.2
0]40
.8 [1
.61]
Side View
ROW E
ROW D
ROW C
ROW B
ROW A
1 6
Communication interface
Pin definition of communication interface:
Pin Definition Description
A4 ISHARE+ ISHARE+
A5 ISHARE- ISHARE-
A6 ADDR3 Address3
B1 PRESENTTo indicate to the system that the module is inserted in the power bay. This pin has been shorted to the
VCC_GND in the module
B2 VCC_GND Return loop of VCC which come from the system
B4, B5 ON/OFF ON/OFF control signal (H:OFF; L:ON)
B6 ADDR2 Address2
C5 ADD5 Address5
C6 ADD1 Address1
D1 CAN_L_1 CAN L of channel 1
D3 CAN_L_0 CAN L of channel 0
D5 ADDR4 Address4
D6 ADDR0 Address0
E1 CAN_H_1 CAN H of channel 1
E3 CAN_H_0 CAN H of channel 0
E5 ENABLEOutput enable control (H:disable.L:enable), when “ON/OFF” and “ENABLE” both be enabled, the
module can output
E6 ADDR_GND Address signal GND
A1 - A3, C1 - C4, D2, D4, E2, E4
NA -
DC Output: -48V RTN Communication Interface
AC input: PE L N
Tolerances±0.5[0.02in.] (≤63[2.48])±1.0[0.04in.] (>63[2.48])
Input connector: JONHON (CZ36E-3T)Output socket:DC output---MOLEX (75556-1500)Communication interface: Tyco (5223008-1)
53
COMMUNICATION CUSTOM POWER SERIES
PAC1600T5453-CB Power Module
Introduction
PAC1600T5453-CB cassette AC-DC power module has 90 to 290Vac wide input voltage, 53V/52.5/3.3V triple isolated outputs, total rating output power 1600W. The module is configured with fan for cooling through a left-to-right airflow, support Hot-swap. Surge protection meet IEC61000-4-5 and ITU-TK.21 standard. Be suitable for the application of switches, routers and so on.
Model Parameter Notes & Conditions
Output characteristics
Output voltage range [email protected] ~ [email protected] ~ [email protected] - 3.57 V
-
Output power PAC1600T5453-CBVo1@[email protected]@7.6A
22A@Vin=176 - 290V, <22A@Vin=90-175V7.6A@Vin=176 - 290V, <7.6A@Vin=90-175V7.6A@Vin=90 - 290V
Output line regulation PAC1600T5453-CB 2%Vo Vin=90 - 290 VAC; Po=1600W
Output load regulation PAC1600T5453-CB 5%Vo Vin=220 VAC; Po=0 - 1600W
Output ripple and noise (PK-PK) PAC1600T5453-CBVo1@300mVVo2@300mVVo3@100mV
Oscilloscope bandwidth: 20 MHz
Input characteristics
Operating input voltage PAC1600T5453-CB 90 - 290 VAC@50/60Hz -
Maximum input current PAC1600T5453-CB 10A Vin=220 VAC; Po=1600W
Power factor PAC1600T5453-CB ≥0.95Vin=110 VAC; Po=986WVin=220 VAC; Po=1600W
Protection characteristics
Input OVP PAC1600T5453-CBTurn on: 290V ACTurn off: 295V AC
Hysteresis: ≥5.0V
Input UVP PAC1600T5453-CBTurn on: 90V ACTurn off: 85V AC
Hysteresis: ≥5.0V
Output OVP PAC1600T5453-CBVo1/[email protected] - 61.5V
[email protected] - 4.9VLatch-offHiccup
Over current Protection PAC1600T5453-CBVo1+Vo2@30 - 33 [email protected] - 22.5A
Hiccup
Over temperature Protection PAC1600T5453-CB - Self-recovery
Absolute maximum ratings
Operating ambient temperature PAC1600T5453-CB -5 - 55ºC -
Storage temperature PAC1600T5453-CB -40 - 70ºC -
Other characteristics
I2C communication PAC1600T5453-CB
Input power;Output voltage;
Air inlet temperature;Remote reset (10s);
Fault alarm:Fan failure alarm;
OTP alarm;
-
Impulse current PAC1600T5453-CB DM: 3kA, CM: 5kA -
Surge PAC1600T5453-CBLine to earth: ±6 kVLine to line: ±6 kV
IEC61000-4-5/ITU-TK.21
Mean time between failures (MTBF) PAC1600T5453-CB 0.25 million hoursTelcordia SR332, Vin=220VAC, 100% load, TA=25ºC
Specification
Features
• Over current protection • Short circuit protection • Output overvoltage protection • Over temperature protection • I2C communication protocol • Hot swap • Suitable for the TT, TN, IT power
supply system • 1+1 redundant backup
54
COMMUNICATION CUSTOM POWER SERIES
Model Input Voltage Output Voltage Output Current Output Power Efficiency
PAC1600T5453-CB 100 - 240 VacVo1: 53.5VVo2: 52.5VVo3: 3.4V
22A/7.6A/7.6A
1600W 91.0%
Model Selector
Pin definition of J3:
Pin Definition Type Description
a1 CARDIN_PWR Output
Detect whether the power module securely connects to the system
backplane. If yes, pin a1 and pin c1 are short-circuited; if not, pin a1 and pin c1
are disconnected.
a2, a5, a9 NC N/A NC
a3 ISHARE+ Output Current share bus +
a4 ISHARE- Output Current share bus -
a6 - a8 Vout3 Output Output: 3.3 V
a10 I2C_SCK_PWR Output/Input I2C clock signal
a11 I2C_SDA_PWR Output/Input I2C data signal
b1 - b11 NC N/A -
c1 - c11 GND N/A GND
d1 - d11 NC N/A -
e1 - e8 Vout3 Output Output: 3.3 V
e9 - e10 NC N/A -
e11 CARDIN_PWR Output Same function as pin a1
Mechanical Diagram
Unit: mm [in.]
[0.856±0.007]
21.8±0.2
[0.3
15±
0.00
5]8.
0±0.
2
[1.8
11±
0.00
7]
46.0
±0.
2
[0.9
84±
0.00
3]25
.0±
0.1
[4.4
69±
0.00
3]11
3.5±
0.1 [0
.461
±0.
003]
11.7
±0.
1
[1.9
09±
0.00
3]
48.5
±0.
1
[1.2
80±
0.00
3]32
.5±
0.1
[0.4
67±
0.00
3]11
.9±
0.1
[0.6
30±
0.00
3]16
.0±
0.1
[0.4
67±
0.00
3]11
.9±
0.1
[7.2
36
]
+0.
007
-0.0
23
183.
8+
0.2
-0.6
[7.915 ]+0.000-0.015
[8.238 ]+0.011-0.015
209.3-0.4+0.3
201.1 0-0.4
155
05
05
Top View
Side View
15.9
±0.
1
[0.6
26±
0.00
3]
0.6±
0.1
[0.0
24±
0.00
3]
[1.6
34
]
+0.
000
-0.0
11
41.5
0 -0.3
Front View
[0.6
14±
0.00
7]
15.6
±0.
2
[7.614 ]+0.000-0.011
93.4 0-0.3
IN ON
OFF
29911619 PSU1600-AC
OUT
FAULT
Back View
J3 J2 J1
RTNRTN Vo2 RTN
Output Socket
edcba
11 1
Vo1
Tolerances±0.5[0.02in.] (≤63[2.48])±1.0[0.04in.] (>63[2.48])
Input connector: IEC 60320 C14Output socket: J1----FCI (10073379-001LF) J2----STARCONN (095U03-00410A-M9) J3----FCI (HM2R30PA5100N9LF)
55
Copyright © Huawei Technologies Co., Ltd. 2014. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
General Disclaimer
The information in this document may contain predictive statements including,
without limitation, statements regarding the future financial and operating results,
future product portfolio, new technology, etc. There are a number of factors
that could cause actual results and developments to differ materially from those
expressed or implied in the predictive statements. Therefore, such information
is provided for reference purpose only and constitutes neither an offer nor an
acceptance. Huawei may change the information at any time without notice.
Trademark Notice
, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.
Other trademarks, product, service and company names mentioned are the property of their respective owners.
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Industrial Base
Bantian Longgang
Shenzhen 518129, P.R. China
Tel: +86-755-28780808
Version No.: M3-031424-20140425-C-2.0
www.huawei.com
COMMUNICATION CUSTOM POWER SERIES
Features
• Over current protection • Short circuit protection • Output overvoltage protection • Over temperature protection • I2C communication protocol
PAC320D2805-CN Power Module
Introduction
PAC320D2805-CN cassette AC-DC power module has 90 to 290Vac wide input voltage, 28V and 5V dual outputs. The output voltage of 28V can be adjusted from 17V to 30.5V through the IIC bus. A radiator should be pasted to the shell for cooling. The module built-in 20KA lightning protection component, and surge protection to meet IEC61000-4-5 standard. Be suitable for the power supply of wireless base station.
Model Parameter Notes & Conditions
Output characteristics
Output voltage range PAC320D2805-CN17 - 30.5V
5.48 - 5.71V-
Output power PAC320D2805-CNVo1: 320WVo2: 75W
The whole range of Vin, Iout and TA, Po1+Po2<320W
Output line regulation PAC320D2805-CN 1%Vo Vin=90 - 290 VAC; Po=320W
Output load regulation PAC320D2805-CN 2%Vo Vin=220 VAC; Po=0 - 320W
Output ripple and noise (PK-PK) PAC320D2805-CNVo1@200mVVo2@50mV
Oscilloscope bandwidth: 20 MHz
Input characteristics
Operating input voltage PAC320D2805-CN 90 - 290 VAC@50/60Hz -
Maximum input current PAC320D2805-CN 7A Vin=220 VAC; Po=320W
Power factor PAC320D2805-CN 0.95 Vin=220 VAC; Po=320W
Protection characteristics
Input OVP PAC320D2805-CNTurn on: 290V ACTurn off: 295V AC
Hysteresis: 5.0V
Input UVP PAC320D2805-CNTurn on: 90V ACTurn off: 85V AC
Hysteresis: 5.0V
Output OVP PAC320D2805-CNVo1@36V
Vo2 hiccup while Vo1 OVPHiccup
Over current Protection PAC320D2805-CNVo12@18 AVo2@15 A
Hiccup
Over temperature Protection PAC320D2805-CN - Self-recovery
Absolute maximum ratings
Operating ambient temperature PAC320D2805-CN -40 - 45ºC -
Storage temperature PAC320D2805-CN -40 - 70ºC -
Other characteristics
I2C communication PAC320D2805-CN
Input power; Adjust output voltage;
Fault alarm; Remote power off;
-
Impulse current PAC320D2805-CN DM: 20kA, CM: 20kA -
Surge PAC320D2805-CNLine to earth: ±4 kVLine to line: ±2kV
IEC61000-4-5/ITU-TK.21
Mean time between failures (MTBF) PAC320D2805-CN 0.25 million hoursTelcordia SR332, Vin=220VAC, 100% load, TA=25ºC
Specification
56
COMMUNICATION CUSTOM POWER SERIES
Model Input Voltage Output Voltage Output Current Output Power Efficiency
PAC320D2805-CN 90 - 290 VacVo1: 28VVo2: 5.5V
11.43A13.67A
320W 91.0%
Model Selector
Mechanical Diagram
Unit: mm [in.]
Side ViewSide View
241.3 [9.50]
10-M3X6
38.2
[1.5
0]
95.5 [3.76]
11.1 [0.44]
37.6
[1.4
8]
Top View Side View
8.2
[0.3
2]
AC input: N L
14190148
14100077
23.9 [0.94]
5-4.0 [0.16]
6-1.1x1.1
95.5 [3.76]
106.6 [4.19]
37.6
[1.4
8]
14190148
14100077
1 1
DC Output Connector
Power GNDCommunication
Connector
Tolerances±0.5[0.02in.] (≤63[2.48])±1.0[0.04in.] (>63[2.48])
Input connector: N---SuZhou Huazhan (H18S) L---SuZhou Huazhan (H18P)
Output connector:DC output---Senda Zhejiang (VH-6A-B1-HW)Communication interface---Senda Zhejiang (SDW12502-8A-C-HW)Power GND---SuZhou Huazhan (H18P)
Pin definition of communication connector
Pin Definition Description
1 AC_DOWN AC input power off alarm
2 PWR_ID_1 Module identification ID_1
3 PWR_ID_0 Module identification ID_0
4 PWR_DWN_M Remote power off
5 GND Signal GND
6 PWR_I2CRS I2C reset control (remain high>700ms)
7 PWR_I2C_SDA I2C data signal
8 PWR_I2C_SCL I2C clock signal
Pin definition of DC output connector
Pin Definition Description
1 PWR_5V5 Output: 5.5V
2 PWR_5V5 Output: 5.5V
3 PWR_5V5 Output: 5.5V
4 V28 Output: 28V
5 V28 Output: 28V
6 V28 Output: 28V
Pin definition of J3:
57
COMMUNICATION CUSTOM POWER SERIES
Features
• Over current protection • Short circuit protection • Output overvoltage protection • Over temperature protection • I2C communication protocol • Hot swap • Suitable for the TT, TN, IT power
supply system • 1+1 redundant backup
PAC600S12-CE/CB Power Module
Introduction
PAC600S12 series cassette AC-DC power module have 90 to 290Vac wide input voltage, 12V and 3.3V dual outputs, total rating output power 600W. The module is configured with fan for cooling through a back-to-front airflow or the reverse direction. This series has two version, and the only difference is the airflow direction. Surge protection meet IEC61000-4-5 and ITU-TK.21 standard. Be suitable for switches, routers, access equipments, server, storage and so on, that need power supply of 12V.
Model Parameter Notes & Conditions
Output characteristics
Output voltage range ALL11.64 ~ 12.36V
3 - 3.8 V-
Output power ALL 12V@600W -
Output line regulation ALL 2%Vo Vin=90 - 264 VAC; Po=600W
Output load regulation ALL 3%Vo Vin=220 VAC; Po=0 - 600W
Output ripple and noise (PK-PK) ALL 12V@200mV Oscilloscope bandwidth: 20 MHz
Input characteristics
Operating input voltage ALL 90 - 290 VAC@50/60Hz -
Maximum input current ALL 7.8A Vin=220 VAC; Po=600W
Power factor ALL ≥0.95 Vin=220 VAC; Po=600W
Protection characteristics
Input UVP ALLTurn on: 90V ACTurn off: 85V AC
Hysteresis: 5.0V
Output OVP ALL 13.5 ~ 16V Hiccup
Over current Protection ALL 52 - 60A Hiccup
Over temperature Protection ALLE: 70ºCB: 60ºC
Self-recovery
Absolute maximum ratings
Operating ambient temperature ALL -25 - 55ºC -
Storage temperature ALL -40 - 85ºC -
Other characteristics
I2C communication ALL
Output voltage/current/power Electronic label
(Rating output power, Device type, Device name)
-
Surge ALLLine to earth: ±6 kVLine to line: ±6 kV
IEC61000-4-5/ITU-TK.21
Mean time between failures (MTBF) ALL 0.25 million hoursTelcordia SR332, Vin=220VAC, 100% load, TA=25ºC
Specification
58
COMMUNICATION CUSTOM POWER SERIES
Pin definition of output connector:
Pin Definition Description
P3 12V+12V output
P4 12VGND
D2 SHARE-12V12V output current sharing signal, when two modules working
in current sharing mode, this pin of each module should connect together
D3 PG-12VIndicator whether the 12V output voltage is OK
(H:OK, L:abnormal)
D4 3.3V3.3V power supply from the main board, giving I2C chip power
supply of module
D5 I2C-SDA I2C data signal
D6 I2C-SCL I2C clock signal
C4 A0 I2C E2PROOM address0
C5 A1 I2C E2PROOM address1
C6 PRESENTTo indicate to the system that the module is inserted in the power
bay. This pin has been shorted to the 12VGND in the module
B2 Alarm AC input power off or UVP alarm signal (H:OK, L:abnormal)
B3 3V3 Output: 3.3V/100mA
B4 WPWrite Protect: this pin should connected to 3.3V power supply
from the main board, using 12VGND
B6 A2 I2C E2PROOM address2
A3 SHARE-48V48V output current sharing signal, when two modules working
in current sharing mode, this pin of each module should connect together
A4 PG-48VIndicator whether the 48V output voltage is OK
(H:OK, L:abnormal)
A5 PSKILLHot swap signal, short pin, when this pin connect to the 12VGND
by the back board, the module be enable
P2 48V-48V output
P1 48V+(RTN)
Model Input Voltage Output Voltage Output Current Output Power Efficiency Notes
PAC600S12-CE 90 - 290 Vac 12V/3.3V 50A/0.1A 600W 90.5% E: back-to-front airflow
PAC600S12-CB 90 - 290 Vac 12V/3.3V 50A/0.1A 600W 90.5% B: front-to-back airflow
Model Selector
Mechanical Diagram
Unit: mm [in.]
90
.0 [
3.5
4] 195.5 [7.70]
204.7 [8.06]
22.3 [0.88]
57
.2 [
2.2
5]
16
.4 [
0.6
5]
5.0
[0
.20
]
4.0
[0
.16
]
8.0
Top View
100.7 [3.96]
99.0 [3.90]
43
.0 [
1.6
9]
35.1 [1.38]
4.0 [0.16]
38.0 [1.50]5.0 [0.20]
Front View
39
.6 [
1.5
6]
14
.6 [
0.5
7]
3.6
[0
.14
]
Side View Back View
90.0 [3.54]
93.4 [3.68]
Output Connector
HD
TM TM TM TM
HD
PART NUMBER ROWS POWER POWER
1 8 9 2 2 0 0 - 5
SIGNAL
DCBA
P 1 P 2 P 3 P 4 1
JKNS
JKNS
JKNS
JKNS
JKNS
JKNS
2 3 4 5 6
Tolerances±0.5[0.02in.] (≤63[2.48])±1.0[0.04in.] (>63[2.48])
Input connector: IEC 60320 C14Output connector: Tyco (1892200-5)
59