Specifications Specification Bulletin 911-31 December 19, 2011 © S&C Electric Company S&C Cypoxy ® Insulators Indoor and Outdoor Distribution (4.8 kV through 46 kV) Conditions of Sale STANDARD: Seller’s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: INCLUSIONS: S&C Cypoxy Insulators are manufactured utilizing S&C’s proprietary Cypoxy cycloaliphatic epoxy resin system. The Cypoxy material is nontracking, self- scouring, and nonweathering. The standard color for S&C Cypoxy Insulators is gray. No other colors are available. S&C Cypoxy Insulators are furnished with embedded aluminum inserts, threaded to accommodate standard galvanized bolts. As noted in the appropriate tables on pages 2 through 6, the sets of inserts at the two ends of S&C Apparatus Insulators are furnished in one of two standard configurations: either in-line or with a 90° offset relative to each other. EXCLUSIONS: S&C Cypoxy Insulators do not include mounting hardware. How to Order 1. Obtain the catalog number of the desired Cypoxy Insulator from the tables on pages 2 through 6. 2. Obtain the suffix letter of spacer-adapters, if desired, from the table on page 7.

Upload: trinhthu

Post on 06-Jul-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Specifications

Specification Bulletin 911-31December 19, 2011 ©S&C Electric Company

S&C Cypoxy® InsulatorsIndoor and Outdoor Distribution (4.8 kV through 46 kV)

Conditions of Sale

STANDARD: Seller’s standard conditions of sale set forth in Price Sheet 150 apply.

SPECIAL TO THIS PRODUCT:

INCLUSIONS: S&C Cypoxy Insulators are manufactured utilizing S&C’s proprietary Cypoxy cycloaliphatic epoxy resin system. The Cypoxy material is nontracking, self-scouring, and nonweathering. The standard color for S&C Cypoxy Insulators is gray. No other colors are available.

S&C Cypoxy Insulators are furnished with embedded aluminum inserts, threaded to accommodate standard galvanized bolts. As noted in the appropriate tables on

pages 2 through 6, the sets of inserts at the two ends of S&C Apparatus Insulators are furnished in one of two standard configurations: either in-line or with a 90° offset relative to each other.

EXCLUSIONS: S&C Cypoxy Insulators do not include mounting hardware.

How to Order

1. Obtain the catalog number of the desired Cypoxy Insulator from the tables on pages 2 through 6.

2. Obtain the suffix letter of spacer-adapters, if desired, from the table on page 7.

S&C Cypoxy® Insulators

2 S&C Specification Bulletin 911-31

OUTDOOR STATION POST INSULATORS1

TypeInsert

Configuration

Rating, kV Height, Inches (mm)

Leakage Distance,

Inches (mm)

Creepage Distance, mm/kV2

Cantilever Strength,

Pounds34

Catalog Number

Page Reference for Dimensional InformationNominal BIL

Apparatus

In-Line

4 inserts each end, 30 (76 mm) bolt spacing;

Z\x0–13 3 C\v0 tapped holes

14.4 11010

(254)16M\, (429)

29.8 2000 PA-7252R1 8

25/34.5h 15014

(356)26Z\v (667)

26.7 2000 PA-7253R1 8

34.5 20018

(457)37C\, (949)

27.5 2000 PA-7254R1 8

46 25022

(559)57C\,

(1457)31.7 2000 PA-7255 8

1 S&C Cypoxy station post insulators meet or exceed the electrical and mechanical-strength requirements established in ANSI Standard C29.9 (1983) for porcelain standard-strength station post insulators.

2 Calculated at nominal voltage.

3 To attain their rated cantilever strengths, Cypoxy Insulators must be mounted on a flat surface that is at least as wide as the diameter of the base of the insulator. Furthermore, the mounting surface must be free of protrusions, such as lumps from galvanizing, to prevent cracking of the insulator when mounting bolts are tightened.

4 These insulators have tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked “Base”) must be oriented toward the mounting surface.

h Applicable at 34.5 kV where the leakage distance to ground meets user’s requirements.

S&C Cypoxy® Insulators

S&C Specification Bulletin 911-31 3

1 Calculated at nominal voltage.2 To attain their rated cantilever strengths, Cypoxy Insulators must be mounted on a flat surface that is at least as wide as the diameter of the base of the insulator. Furthermore, the mounting surface must be free of protrusions, such as lumps from galvanizing, to prevent cracking of the insulator when mounting bolts are tightened.l This insulator serves as a blade spacer in S&C Regulator Bypass Switches—Type XL. When used alone its nominal rating is 600 volts.

d This insulator has tapered root diameters. To attain the rated cantile-ver strength, the end with the larger root diameter (marked “Base”) must be oriented toward the mounting surface.f For indoor use only, when applied at 34.5 kV.

a Supersedes Catalog Number PA-7193. When replacing Insulator Catalog Number PA-7193, specify one Spacer-Adapter Catalog Number S-86542.

INDOOR-OUTDOOR INSULATORS

TypeInsert

Configuration

Rating, kV Height, Inches (mm)

Leakage Distance,

Inches (mm)

Creepage Distance, mm/kV1

Cantilever Strength, Pounds2

Catalog Number

Page Reference for Dimensional InformationNominal BIL

Apparatus

90° Offset

2 inserts each end, 2Z\v0 (57 mm) bolt

spacing; Z\,0–16 3 B\,0 tapped holes

14.4 1106 C\v

(171)14Z\, (359)

24.9 1200 PA-7191d 9

25 15010

(254)24Z\, (613)

24.5 1000 PA-7192d 9

In-Line

4 inserts each end, 30 (76 mm) bolt spacing;

Z\x0–13 3 C\v0 tapped holes

34.5 20014

(356)26Z\v (667)

19.3 2000 PA-7253R1dfa 9

Specialty

In-Line

1 insert each end, centered;

Z\x0–13 3 C\,0 tapped hole

l 452 C\v (70)

2C\v (70)

116.7 600 PA-7188 9

S&C Cypoxy® Insulators

4 S&C Specification Bulletin 911-31

1 Calculated at nominal voltage.2 To attain their rated cantilever strengths, Cypoxy Insulators must be mounted on a flat surface that is at least as wide as the diameter of the base of the insulator. Furthermore, the mounting surface must be free of protrusions, such as lumps from galvanizing, to prevent cracking of the insulator when mounting bolts are tightened.

• PA-7205 has 4 inserts at each end with a 2-inch bolt spacing.d This insulator has tapered root diameters. To attain the rated canti-lever strength, the end with the larger root diameter must be oriented toward the mounting surface.

INDOOR INSULATORS

TypeInsert

Configuration

Rating, kV Height, Inches (mm)

Leakage Distance,

Inches (mm)

Creepage Distance, mm/kV1

Cantilever Strength, Pounds2

Catalog Number

Page Reference for Dimensional InformationNominal BIL

Bus

In-Line

1 insert each end, centered;

Z\x0–13 3 C\,0 tapped hole

4.8 603Z\x (89)

4M\, (124)

25.8 1000 PA-7164d 10

13.8 956

(152)12Z\,

(308)22.3 1250 PA-7163d 10

Apparatus

90° Offset

2 inserts each end, 30 (76 mm) bolt spacing;

Z\x0–13 3 C\v0 tapped holes

4.8 605

(127)7 C\v

(197)41.0 1250 PA-7166 10

13.8 957Z\x

(191)13

(330)23.9 1250 PA-7162d 10

In-Line

2 inserts each end, 20 (51 mm) bolt spacing and

2 inserts each end, 1C\,0 (35 mm) bolt spacing•;

C\,–16 3 B\,0 tapped holes

13.8 956Z\v

(159)12Z\v (311)

22.5 1250 PA-7181 10

25 1257Z\x

(191)18Z\x (470)

18.8 1000 PA-7183 10

25 15010

(254)26Z\, (664)

26.6 1000 PA-7205• 10

TABLE CONTINUED v

S&C Cypoxy® Insulators

S&C Specification Bulletin 911-31 5

1 Calculated at nominal voltage.

2 To attain their rated cantilever strengths, Cypoxy Insulators must be mounted on a flat surface that is at least as wide as the diameter of the base of the insulator. Furthermore, the mounting surface must be free of protrusions, such as lumps from galvanizing, to prevent cracking of the insulator when mounting bolts are tightened.

3 These insulators have tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked “Base”) must be oriented toward the mounting surface.

INDOOR INSULATORS—Continued

TypeInsert

Configuration

Rating, kV Height, Inches (mm)

Leakage Distance,

Inches (mm)

Creepage Distance, mm/kV1

Cantilever Strength,

Pounds23

Catalog Number

Page Reference for Dimensional InformationNominal BIL

Apparatus

In-Line

2 inserts, 20 (51 mm) bolt spacing,

C\,0–16 3 B\,0 tapped holes 1 insert, center;

B\,0–11 3 M\,0 tapped hole

4 inserts, 20 (51 mm) bolt spacing;

C\,0–16 3 B\,0 tapped holes

5 603Z\x (89)

6 (152)

30.5 2000 PA-7310 11

15 956

(152)12Z\v (311)

20.7 1250 PA-7280 11

25 125

7Z\x (191)

18Z\x (470)

18.8 1000 PA-7290 11

8Z\x (216)

22Z\x (572)

22.9 1000 PA-7340 11

In-Line

2 inserts, 20 (51 mm) bolt spacing;

C\,0–16 3 B\,0 tapped holes 1 insert, center;

B\,0–11 3 M\,0 tapped hole

2 inserts, 20 (51 mm) bolt spacing;

C\,0–16 3 B\,0 tapped holes

5 603Z\x (89)

6 (152)

30.5 2000 PA-7311 11

15 956

(152)12Z\v (311)

20.7 1250 PA-7281 11

25 125

7Z\x (191)

18Z\x (470)

18.8 1000 PA-7291 11

8Z\x (216)

22Z\x (572)

22.9 1000 PA-7341 11

TABLE CONTINUED v

S&C Cypoxy® Insulators

6 S&C Specification Bulletin 911-31

1 Calculated at nominal voltage.

2 To attain their rated cantilever strengths, Cypoxy Insulators must be mounted on a flat surface that is at least as wide as the diameter of the base of the insulator. Furthermore, the mounting surface must be free of protrusions, such as lumps from galvanizing, to prevent cracking of the insulator when mounting bolts are tightened.

3 These insulators have tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked “Base”) must be oriented toward the mounting surface.

INDOOR INSULATORS—Continued

TypeInsert

Configuration

Rating, kV Height, Inches (mm)

Leakage Distance,

Inches (mm)

Creepage Distance, mm/kV1

Cantilever Strength,

Pounds23

Catalog Number

Page Reference for Dimensional InformationNominal BIL

Apparatus

In-Line

2 inserts, 20 (51 mm) bolt spacing;

C\,0–16 3 B\,0 tapped holes

4 inserts, 20 (51 mm) bolt spacing;

C\,0–16 3 B\,0 tapped holes

5 603Z\x (89)

6 (152)

30.5 2000 PA-7312 11

15 956

(152)12Z\v (311)

20.7 1250 PA-7282 11

25 125

7Z\x (191)

18Z\x (470)

18.8 1000 PA-7292 11

8Z\x (216)

22Z\x (572)

22.9 1000 PA-7342 11

In-Line

4 inserts, 20 (51 mm) bolt spacing;

C\,0–16 3 B\,0 tapped holes

4 inserts, 20 (51 mm) bolt spacing;

C\,–16 3 B\,0 tapped holes

5 603Z\x (89)

6 (152)

30.5 2000 PA-7313 11

15 956

(152)12Z\v (311)

20.7 1250 PA-7283 11

25 125

7Z\x (191)

18Z\x (470)

18.8 1000 PA-7293 11

8Z\x (216)

22Z\x (572)

22.9 1000 PA-7343 11

S&C Cypoxy® Insulators

S&C Specification Bulletin 911-31 7

SPACER-ADAPTERS

Illustration DescriptionHeight, Inches (mm)

For use with Insulator

Catalog NumberCatalog Number

Galvanized stamped steel—for use in adapting 30 (76 mm) insulator-bolt spacing (for Z\x0–13 bolts) to 2Z\v0 (57 mm) bolt spacing (holes at 2Z\v0 [57 mm] bolt spacing are tapped for C\,0–16 bolts)

ZB\zn (24)

PA-7166

PA-7162

PA-7193

S-82274-1

Galvanized stamped steel—for use in adapting 2Z\v0 (57 mm) insulator-bolt spacing (for C\,0–16 bolts) to 30 (76 mm) bolt spacing (for Z\x0–13 bolts)

ZB\zn (24)

PA-7191

PA-7192S-82274-2

Galvanized stamped steel—for use in adapting 20 (51 mm) insulator-bolt spacing (for C\,0–16 bolts) to 30 (76 mm) bolt spacing (for Z\x0–13 bolts)

ZB\zn (24)

PA-7181

PA-7183S-82274-3

Galvanized stamped steel—for use in adapting 1C\,0 (35 mm) insulator-bolt spacing (for C\,0–16 bolts) to 30 (76 mm) bolt spacing (for Z\x0–13 bolts)

ZB\zn (24)

PA-7181

PA-7183S-82274-4

Cast aluminum alloy—for use in adapting 1C\,0 (35 mm) insulator-bolt spacing and 20 (51 mm) insulator-bolt spacing (for C\,0–16 bolts) to 30 (76 mm) bolt spacing (holes at 30 [76 mm] bolt spacing are tapped for Z\x0–13 bolts)

C\v (19)

PA-7181

PA-7183S-86016

Outdoor Station Post Insulators

S&C Cypoxy® Insulators

8 S&C Specification Bulletin 911-31

1 To attain their rated cantilever strengths, Cypoxy Insulators must be mounted on a flat surface that is at least as wide as the diameter of the base of the insulator.

2 These insulators have tapered root diameters. To attain the rated cantilever strength, the end with the larger root diameter (marked “Base”) must be oriented toward the mounting surface.

Type

Ratings

Leakage Distance,

Inches (mm)

Dry Arcing

Distance, Inches (mm)

Mechanical Strength Rating, Pounds

Catalog Number

T.R. Number

(for corre- sponding porcelain

station post

insulator)

Dimensions in Inches (mm)

Net Weight,

Lbs. (Kg.)Nom. BIL

Low Fre-

quency With- stand, 1 Min.

Dry

Low Fre-

quency With- stand, 10 Sec.

Wet

Canti- lever12 Tensile

Com- pression

H D1

Apparatus

14.4

25

34.5

46

110

150

200

250

70

95

95

120

60

80

80

100

16M\, (429)

26Z\v (667)

37C\, (949)

57C\, (1457)

10 (254)

14 (356)

18 (457)

22 (559)

2000

2000

2000

2000

10 000

10 000

12 000

14 000

20 000

20 000

20 000

20 000

PA-7252R1

PA-7253R1

PA-7254R1

PA-7255

205

208

210

214

10 (254)

14 (356)

18 (457)

22 (559)

5 (127)

5Z\v (133)

6 (152)

6Z\x (165)

10 (4.5)

15 (6.8)

21 (9.5)

32 (14.4)

3 (76)

4C\,(111)

C\v (19)

3(76)

3(76)

3 (76)

CATALOG NUMBERSPA-7252R1, PA-7253R1, AND PA-7254R1

Dimensions in inches (mm)

Indoor-Outdoor Insulators

S&C Cypoxy® Insulators

S&C Specification Bulletin 911-31 9

1 To attain their rated cantilever strengths, Cypoxy Insulators must be mounted on a flat surface that is at least as wide as the diameter of the base of the insulator.

l This insulator serves as a blade spacer in S&C Regulator Bypass Switches—Type XL. When used alone its nominal rating is 600 volts.

d This insulator has tapered root diameters. To attain the rated cantile-ver strength, the end with the larger root diameter (marked “Base”) must be oriented toward the mounting surface.

f For indoor use only, when applied at 34.5 kV.h Tapped oversize for galvanized steel hardware.

Type

Ratings

Leakage Distance,

Inches (mm)

Dry Arcing

Distance, Inches (mm)

Mechanical Strength Rating, Pounds

Catalog Number

Dimensions in Inches (mm)

Insert Thread

Size

Net Weight,

Lbs. (Kg.)Nom. BIL

Low Fre-

quency With- stand, 1 Min.

Dry

Low Fre-

quency With- stand, 10 Sec.

Wet

Canti- lever1 Tensile

Com- pression

H R S

Apparatus

14.4

25

34.5

110

150

200

50

70

95

45

60

80

14Z\, (359)

24Z\, (613)

26Z\v (667)

6C\v (171)

10 (254)

14 (356)

1200

1000

2000

5 000

5 000

10 000

20 000

20 000

20 000

PA-7191d

PA-7192d

PA-7253R1df

6C\v (171)

10 (254)

14 (356)

Z\v (6)

Z\v (6)

B\,

(16)

B\,

(16)

C\v (19)

C\,0–16 h

C\,0–16 h

Z\x0–13 h

4Z\x (2.0)

7 (3.2)

15 (6.8)

Specialty l 45 15 —2C\v (70)

2Z\v (57)

600 3 000 20 000 PA-71882C\v (70)

—C\v

(19)Z\x0–13

1 (0.5)

3 (76)

1B\,(41)

4(102)

4C\, (111)

2Z\v (57)

2Z\v(57)

3(76)

3(76)

5Z\v (133)

3 (76)

Dimensions in inches (mm)

Indoor Insulators

S&C Cypoxy® Insulators

10 S&C Specification Bulletin 911-31

1 To attain their rated cantilever strengths, Cypoxy Insulators must be mounted on a flat surface that is at least as wide as the diameter of the base of the insulator.d This insulator has tapered root diameters. To attain the rated cantile-

ver strength, the end with the larger root diameter (marked “Base”) must be oriented toward the mounting surface.f Tapped oversize for galvanized steel hardware.

Type

Ratings

Leakage Distance,

Inches (mm)

Dry Arcing

Distance, Inches (mm)

Mechanical Strength Rating, Pounds

Catalog Number

Dimensions in Inches (mm)

Insert Thread

Size

Net Wt, Lbs. (Kg.)Nom. BIL

Low Fre-

quency With- stand, 1 Min.

Dry

Low Fre-

quency With- stand, 10 Sec.

Wet

Canti- lever1 Tensile

Com- pression

H D1 D2 R S

Bus 4.8

13.8

60

95

19

36

15

26

4M\, (124)12Z\, (308)

3Z\x (89)

6 (152)

1000

1250

2000

3000

20 000

20 000

PA-7164d

PA-7163d

3Z\x (89)

6 (152)

3 (76)3Z\v (83)

2Z\x (64)2C\v (70)

Z\v (6)C\,

(10)

C\v (19)C\v

(19)

Z\x0–13 f

Z\x0–13 f

1Z\x (0.7)2Z\x

(1.1)

Apparatus

4.8

13.8

13.8

25

25

60

95

95

125

150

19

36

36

60

60

15

26

26

40

40

7C\v (197)

13 (330)12Z\v (311)18Z\x (470)26Z\, (664)

5 (127)7Z\x

(191)6Z\v

(159)7Z\x

(191)10

(254)

1250

1250

1250

1000

1000

3000

3000

3000

3000

5000

20 000

20 000

20 000

20 000

20 000

PA-7166

PA-7162d

PA-7181

PA-7183

PA-7205

5 (127)7Z\x

(191)6Z\v

(159)7Z\x

(191)10

(254)

4C\, (111)4C\,

(111)3C\v

(95)4

(102)4

(102)

Z\, (3)Z\, (3)Z\v (6)Z\v (6)Z\v (6)

C\v (19)C\v

(19)B\,

(16)B\,

(16)B\,

(16)

Z\x0–13 f

Z\x0–13 f

C\,0–16 f

C\,0–16 f

C\,0–16

4Z\v (1.9)5C\v

(2.6)4

(1.8)4M\,

(2.2)6Z\x

(2.9)

3(76)

2(51)

2(51)

2 (51)

3 (76)

2 (51)

1C\,(35)

2(51)

2(51)

1C\,(35)

Dimensions in inches (mm)

Indoor Insulators—Continued

S&C Cypoxy® Insulators

S&C Specification Bulletin 911-31 11

1 To attain their rated cantilever strengths, Cypoxy Insulators must be mounted on a flat surface that is at least as wide as the diameter of the base of the insulator.

2 This insulator has tapered root diameters. To attain the rated cantile-ver strength, the end with the larger root diameter (marked “Base”) must be oriented toward the mounting surface.

Type

Ratings

Leakage Distance,

Inches (mm)

Dry Arcing

Distance, Inches (mm)

Mechanical Strength Rating, Pounds

Catalog Number

Dimensions in Inches (mm)

Insert Thread

Size

Net Wt, Lbs. (Kg.)Nom. BIL

Low Fre-

quency With- stand, 1 Min.

Dry

Low Fre-

quency With- stand, 10 Sec.

Wet

Canti- lever 12

Tensile Com- pression D1 D2 H R S

Appar- atus

5 60 19 15 6 (152)

3Z\x (89) 2000 2000 20 000

PA-7310PA-7311

3B\, (92)

3C\, (86)

3Z\x (89)

Center insert: Z\v (6)

20 bolt spacing inserts; Z\v (6)

Center insert: M\, (22)

20 bolt spacing inserts; B\, (16 )

Center insert:

B\,0– (11 )

20 bolt spacing inserts; C\,0 (16 )

2Z\, (1.0)

15 95 36 26 12Z\v (311)

6 (152) 1250 3000 20 000

PA-7280PA-7281

3M\, (98)

3C\v

(95)6

(152)3Z\x

(1.6)

25 125 60 40

18Z\x (470)

7Z\x (191) 1000 3000 20 000

PA-7290PA-7291

4 (102)

4 (102)

7Z\x (191)

4M\, (2.2)

22Z\x (572)

8Z\x (216) 1000 3000 20 000

PA-7340PA-7341

4 (102)

4 (102)

8Z\x (216)

5Z\, (2.3)

2 (51)

2 (51)

D1

D2

2 (51)

H

D1

D2

2 (51)

H

CATALOG NUMBERS PA-7280, PA-7290,

PA-7310, AND PA-7340

CATALOG NUMBERS PA-7281, PA-7291, PA-7311, AND 7341

2 (51)

CATALOG NUMBERSPA-7280, PA-7290,

PA-7310, AND PA-7340

CATALOG NUMBERSPA-7281, PA-7291,

PA-7311, AND PA-7341

Dimensions in inches (mm)

Indoor Insulators—Continued

S&C Cypoxy® Insulators

12 S&C Specification Bulletin 911-31

1 To attain their rated cantilever strengths, Cypoxy Insulators must be mounted on a flat surface that is at least as wide as the diameter of the base of the insulator.

2 This insulator has tapered root diameters. To attain the rated cantile-ver strength, the end with the larger root diameter (marked “Base”) must be oriented toward the mounting surface.

Type

Ratings

Leakage Distance,

Inches (mm)

Dry Arcing

Distance, Inches (mm)

Mechanical Strength Rating, Pounds

Catalog Number

Dimensions in Inches (mm)

Insert Thread

Size

Net Wt, Lbs. (Kg.)Nom. BIL

Low Fre-

quency With- stand,

1 Min. Dry

Low Fre-

quency With- stand, 10 Sec.

Wet

Canti- lever 12

TensileCom-

pressionD1 D2 H

Apparatus

5 60 19 15 6 (152)

3Z\x (89) 2000 2000 20 000

PA-7312PA-7313

3B\, (92)

3C\, (86)

3Z\x (89)

C\,0– (16 )

2Z\, (1.0)

15 95 36 26 12Z\v (311)

6 (152) 1250 3000 20 000

PA-7282PA-7283

3M\, (98)

3C\v

(95)6

(152)3Z\x

(1.6)

25 125 60 40

18Z\x (470)

7Z\x (191) 1000 3000 20 000

PA-7292PA-7293

4 (102)

4 (102)

7Z\x (191)

4M\, (2.2)

22Z\x (572)

8Z\x (216) 1000 3000 20 000

PA-7342PA-7343

4 (102)

4 (102)

8Z\x (216)

5Z\, (2.3)

CATALOG NUMBERSPA-7282, PA-7292,

PA-7312, AND PA-7342

CATALOG NUMBERSPA-7283, PA-7293,

PA-7313, AND PA-7343

Dimensions in inches (mm)

Prin

ted

in U

.S.A

.