spec. no. 17-07 - fountain maintenance request for
TRANSCRIPT
pentairpool.com
BRING FOUNTAINS TO LIFE WITH BRILLIANT WHITE OR DAZZLING COLOR
Pentair Fountain Fixtures are the only fixtures that offer true color lighting capabilities. When combined with IntelliBrite® 5g LED Pool and Spa Lights, these systems will bathe fountains in a constantly changing spectrum of color. Both large and small fixtures are designed for easy installation; just assemble the cradle assembly, drop in the light and install the rock guard.
FOUNTAIN FIXTURES
NICHE MOUNT KITS
Large lights—Part No. 560002 Small lights—Part No. 560003 Light and niche sold separately.
• Sturdy cast-bronze construction with attractive natural bronze finish.
• Base and yoke-mount rotate 360° and pivot 180°.
• Large fixture for use with IntelliBrite 5g Pool Lights listed for fountain use.
• Small fixture for use with IntelliBrite 5g Spa Lights and SpaBrite® Lights listed for fountain use.
FOUNTAIN FIXTURES FOR DECORATIVE FOUNTAINS
DRAFT
1620 HAWKINS AVE, SANFORD, NC 27330 800.831.7133 WWW.PENTAIRPOOL.COM All Pentair trademarks and logos are owned by Pentair or one of its global affiliates. IntelliBrite® and SpaBrite® are registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/or other countries. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.
pumps • filters • heaters • heat pumps • automation • lighting • cleaners • sanitizers • water features • maintenance products7/15 Part # P1-536 ©2015 Pentair Water Pool and Spa, Inc. All rights reserved.
AVAILABLE FROM:
BATHE FOUNTAINS WITH BRILLIANT WHITE OR A SPECTRUM OF COLOR
IntelliBrite® 5g LED Pool and Spa Lights allow you to highlight your fountain in a custom color or slowly roll through the entire color spectrum.
Additional features include:
• Integrated bonding lug for electrical safety.
• Strain-relief prevents damage to wiring connections.
• Niche installation option available.
• UL Listed with Pentair lights only.
12" Diameter
12"
14.25" Diameter 10" Diameter
7.25" Diameter
8"
Fountain Fixture for large lights
Part No. 560000 (Light sold separately)
Fountain Fixture for small lights Part No. 560001
(Light sold separately)
Simple design for quick and easy assembly
Rock guard
Light support ring
Yoke
Base
Cradle assembly
FOUNTAIN FIXTURESFOR DECORATIVE FOUNTAINS
DRAFT
(4) 5/8" DIA.HILTI KWIK BOLT TZ-SS4" MIN. EMBEDMENT
(ESR 1917), TYP.
MCC PANEL
EXISTINGPANEL
8"1'
-0"
A.F.
F.3'
-6"
F.F.
2'-6"
2"
8"1'
-0"
A.F.
F.3'
-6"
MOUNTING HARDWARE,(TYP. OF 4 PLACES)
F.F.
HOUSEKEEPING PAD
1-5/8 X 1-5/8 SQUARE TUBING,PER UNISTRUT MODEL #P9000ON THE BACK OF MCC PANEL.PROVIDE 3/8" DIA. ASTM A449 THRUBOLT ATTACHMENT TO THE MCC PANELPER HORIZONTAL STRUT
EQ.
EQ.
SIDE VIEW FRONT VIEW
3" C
LR.
TYP.
#4 BARS @ 12" O.C. E.W.(4) 5/8" DIA.HILTI KWIK BOLT TZ-SS4" MIN. EMBEDMENT
(ESR 1917), TYP.
1MCC PANEL & TRANSFORMER ANCHORAGE EXHIBIT - 11/29/2017SCALE: 1" = 1'-0"
UNISTRUT BASE,(TYP. OF 2 PLACES)
ELECTRICAL CONDUITSAS REQUIRED
3" CLR.TYP.
ELECTRICAL CONDUITSAS REQUIRED
1-5/8 X 1-5/8 SQUARE TUBINGWITH 9/16" HOLES PERUNISTRUT MODEL #P9000, TYP.
MCC PANEL
3" CLR.TYP.
DRAFT
TIME SETTINGTO SET THE CURRENT TIME (AND DAY OF WEEK ON 7 DAY UNITS), TURN THE MINUTE HAND CLOCKWISE. DO NOT SET THE TIME BY ROTATING “OUTER” DIAL.
Turn the minute hand clockwise until the day of the week (7-day timer) and the time of day on the outer dial is aligned with the triangle marker on the inner dial (two o’clock position).
Example for 7-day program dial Monday 10:30 AM. Turn the minute hand clockwise until Monday 10:30 AM is aligned with the triangle on the inner dial. The hour and minute hand will show exactly 10:30.
Example for 24-hour program dial 10:30 AM. Turn the minute hand clockwise until 10:30 AM is aligned with the triangle on the inner dial. The hour and the minute dial will show exactly 10:30.
PROGRAMMING7-Day (SW, QRW Models)
The weekly program dial reflects the seven days of the week and AM/PM imprints for each day.
The time switch is programmed by pushing the captive trip-pers to the outer ring position for the entire period that the load is to be turned “ON”, i.e., two hours for each tripper on the 7-Day dial. When the tripper is pushed to the inside, the switch is in the “OFF” position.
24-Hour (ST, QRT Models)
The 24-Hour dial has quarter-hour divisions and AM/PM indications.
The time switch is programmed by pushing the captive trip-pers to the outer ring position for the entire period that the load is to be turned “ON”, i.e., fifteen minutes for each trip-per on the 24-Hour dial. When the tripper is pushed to the inside, the switch is in the “OFF” position.
PROGRAMMING WITH MANUAL OvERRIDE SWITCHAUTOMATIC MODE
In order to operate the time switch module in the automatic mode, the manual switch must be in the center position (auto-matic) - see diagram.
MANUAL MODE
With the manual switch selector lever the selected programs can be overridden. In the lower position, marked “O”, termi-nals 3 and 5 are permanently closed. In the upper position, marked “I”, terminals 3 and 4 are permanently closed (see diagram).
158-
-005
24
Override Mode
3-way manual override switch
I = permanent ON = automatic0 = permanent OFF
Dimensions
FM/1 synchronous/quartz
INTERMATIC INCORPORATEDSpring Grove, IL 60081-9698www.intermatic.com
DRAFT
Type 4 Mild Steel Wallmount Enclosure Eclipse SeriesHinge Door with Quarter Turn/Handle
ApplicationDesigned to enclose electrical and/or electronic equipment and protectagainst harsh, industrial environments for wallmount applications.Impressive styling features like hidden hinges, attractive latching systemsmake the Eclipse a suitable addition to any high-tech equipmentinstallation.A wide range of sizes and practical accessories make this product line acomplete package.
StandardsUL 508 Type 3R, 4, and 12CSA Type 3R, 4, and 12Complies with
NEMA Type 3R, 4, and 12IEC 60529, IP66
ConstructionFormed 14 or 16 gauge steel.Smooth, continuously welded seams ground smooth.Door stiffeners are provided where required for increased strength andrigidity - designed to also permit additional mounting options.Formed lip on enclosure to exclude flowing liquids and contaminants.Door latches feature the added safety of quarter turn slot requiring use oftool for opening.Doors may be easily removed for modifications and are interchangeable.Seamless poured-in place gasket.Collar studs provided for mounting inner panel.Includes hardware kit with panel mounting nuts and sealing washers forwall mounting holes.Bonding stud provided on door and grounding stud installed in enclosure.Hinges are constructed from 304 stainless steel.Hinge pins are stainless steel.Quarter turn latch and multi-point handle (key lockable) are zinc diecastwith black epoxy finish.Door alignment guide provided on 36" wide enclosures.
FinishCover and enclosure are phosphatized and finished with a recoatablepowder inside and out with choice of ANSI 61 smooth Gray (GY) or RAL7035textured light gray (LG).
Accessories
Quality Products. Service Excellence.
DRAFT
Cooling Products Blowers and FansVentilation DIN RailsDIN Rail Mounting Kit Drip Shield KitDoor Stop Kit Filtered FansGland Plates HeatersInner Panels HandlesQuarter Turn Inserts and Keys Literature PocketMounting Foot Kit Swing PanelSwing Frame Eclipse Rack PanelRear Hole Plugs Replacement Hinge PinsQuarter Turn Assemblies Temperature ControlsTouch-Up Spray Paint Type 4 Hardware KitsPadlock Adaptor
DRAFT
Part No. Part No.Overall
Dimensions Door/Body LatchesOpt.
Panel Panel SizeShipWt.
(ANSI 61 Gray)(RAL 7035 LightGray) A B C Gauge Qty Type Part No. D E
#Hinges F (lbs)
EN4SD12126GY EN4SD12126LG 12.00 12.00 6.00 16 1 Qtr Turn EP1212 10.20 10.20 2 6.00 12EN4SD12246GY EN4SD12246LG 12.00 24.00 6.00 16 1 Qtr Turn EP1224 10.20 22.20 2 18.00 24EN4SD16126GY EN4SD16126LG 16.00 12.00 6.00 16 1 Qtr Turn EP1612 14.20 10.20 2 10.00 16EN4SD16166GY EN4SD16166LG 16.00 16.00 6.00 16 1 Qtr Turn EP1616 14.20 14.20 2 10.00 19EN4SD16206GY EN4SD16206LG 16.00 20.00 6.00 16 1 Qtr Turn EP1620 14.20 18.20 2 10.00 22EN4SD20126GY EN4SD20126LG 20.00 12.00 6.00 16 1 Qtr Turn EP2012 18.20 10.20 2 14.00 20
DRAFT
EN4SD202410GY EN4SD202410LG 20.00 24.00 10.00 16 1 Qtr.Turn
EP2024 18.20 22.20 2 14.00 36
EN4SD241210GY EN4SD241210LG 24.00 12.00 10.00 16 1 Qtr Turn EP2412 22.20 10.20 2 18.00 26
EN4SD241610GY EN4SD241610LG 24.00 16.00 10.00 16 1 Qtr.Turn
EP2416 22.20 14.20 2 18.00 30
EN4SD242010GY EN4SD242010LG 24.00 20.00 10.00 16 1 Qtr.Turn
EP2420 22.20 18.20 2 18.00 36
EN4SD242410GY EN4SD242410LG 24.00 24.00 10.00 14 2 Qtr.Turn
EP2424 22.20 22.20 2 18.00 45
EN4SD243010GY EN4SD243010LG 24.00 30.00 10.00 14 2 Qtr.Turn
EP2430 22.20 28.20 2 18.00 53
EN4SD302010GY EN4SD302010LG 30.00 20.00 10.00 14 2 Qtr.Turn
EP3020 28.20 18.20 3 12.00 47
EN4SD302410GY EN4SD302410LG 30.00 24.00 10.00 14 2 Qtr.Turn
EP3024 28.20 22.20 3 12.00 53
EN4SD303010GY EN4SD303010LG 30.00 30.00 10.00 14 2 Qtr.Turn
EP3030 28.20 28.20 3 12.00 75
EN4SD362410GY EN4SD362410LG 36.00 24.00 10.00 14 2 Qtr.Turn
EP3624 34.20 22.20 3 15.00 70
EN4SD363010GY EN4SD363010LG 36.00 30.00 10.00 14 2 Qtr.Turn
EP3630 34.20 28.20 3 15.00 84
EN4SD363610GY EN4SD363610LG 36.00 36.00 10.00 14 2 Qtr.Turn
EP3636 34.20 34.20 3 15.00 100
EN4SD423010GY EN4SD423010LG 42.00 30.00 10.00 14 1 3-point EP4230 40.20 28.20 4 12.00 107EN4SD423610GY EN4SD423610LG 42.00 36.00 10.00 14 1 3-point EP4236 40.20 34.20 4 12.00 117EN4SD482410GY EN4SD482410LG 48.00 24.00 10.00 14 1 3-point EP4824 46.20 22.20 4 14.00 95EN4SD483010GY EN4SD483010LG 48.00 30.00 10.00 14 1 3-point EP4830 46.20 28.20 4 14.00 120EN4SD483610GY EN4SD483610LG 48.00 36.00 10.00 14 1 3-point EP4836 46.20 34.20 4 14.00 125EN4SD603610GY EN4SD603610LG 60.00 36.00 10.00 14 1 3-point EP6036 58.20 34.20 4 18.00 150EN4SD201612GY EN4SD201612LG 20.00 16.00 12.00 16 1 Qtr Turn EP2016 18.20 14.20 2 14.00 32EN4SD202012GY EN4SD202012LG 20.00 20.00 12.00 16 1 Qtr Turn EP2020 18.20 18.20 2 14.00 34EN4SD242012GY EN4SD242012LG 24.00 20.00 12.00 16 1 Qtr Turn EP2420 22.20 18.20 2 18.00 38EN4SD242412GY EN4SD242412LG 24.00 24.00 12.00 14 2 Qtr Turn EP2424 22.20 22.20 2 18.00 47EN4SD302412GY EN4SD302412LG 30.00 24.00 12.00 14 2 Qtr Turn EP3024 28.20 22.20 3 12.00 57EN4SD303012GY EN4SD303012LG 30.00 30.00 12.00 14 2 Qtr Turn EP3030 28.20 28.20 3 12.00 80EN4SD362412GY EN4SD362412LG 36.00 24.00 12.00 14 2 Qtr Turn EP3624 34.20 22.20 3 15.00 62EN4SD363012GY EN4SD363012LG 36.00 30.00 12.00 14 2 Qtr Turn EP3630 34.20 28.20 3 15.00 91EN4SD363612GY EN4SD363612LG 36.00 36.00 12.00 14 2 Qtr Turn EP3636 34.20 34.20 3 15.00 104EN4SD423012GY EN4SD423012LG 42.00 30.00 12.00 14 1 3-point EP4230 40.20 28.20 4 12.00 111EN4SD423612GY EN4SD423612LG 42.00 36.00 12.00 14 1 3-point EP4236 40.20 34.20 4 12.00 121EN4SD482412GY EN4SD482412LG 48.00 24.00 12.00 14 1 3-point EP4824 46.20 22.20 4 14.00 98EN4SD483612GY EN4SD483612LG 48.00 36.00 12.00 14 1 3-point EP4836 46.20 34.20 4 14.00 148EN4SD603612GY EN4SD603612LG 60.00 36.00 12.00 14 1 3-point EP6036 58.20 34.20 4 18.00 165
EN4SD723012GY EN4SD723012LG 72.00 30.00 12.00 14 2Qtr
Turn,5-point
EP7230 70.20 28.20 5 16.50 190
EN4SD723612GY EN4SD723612LG 72.00 36.00 12.00 14 2Qtr
Turn,5-point
EP7236 70.20 34.20 5 16.50 195
EN4SD242016GY EN4SD242016LG 24.00 20.00 16.00 16 1 Qtr Turn EP2420 22.20 18.20 2 18.00 52EN4SD242416GY EN4SD242416LG 24.00 24.00 16.00 14 2 Qtr Turn EP2424 22.20 22.20 2 18.00 66EN4SD302416GY EN4SD302416LG 30.00 24.00 16.00 14 2 Qtr Turn EP3024 28.20 22.20 3 12.00 85EN4SD363016GY EN4SD363016LG 36.00 30.00 16.00 14 2 Qtr Turn EP3630 34.20 28.20 3 15.00 102EN4SD423616GY EN4SD423616LG 42.00 36.00 16.00 14 1 3-point EP4236 40.20 34.20 4 12.00 140
Part No. Part No.Overall
Dimensions Door/Body LatchesOpt.
Panel Panel SizeShipWt.
(ANSI 61 Gray)(RAL 7035 LightGray) A B C Gauge Qty Type Part No. D E
#Hinges F (lbs)
DRAFT
Exhaust Filters Replacement Filters
297-560 CFM Slimline Filterfans PF SL GEN4 SeriesType 12
Low installation depthMaintains a UL Tested NEMA Type 12 seal against enclosureUL Recognized to UL 508a, category NITW2/8,UL File #E175229CSA #246217Patented “Click & Fit” design provides a hardwarefree installation!Plastic made from strong, heat resistant(ABS-FR), UL 94 VO fire approved materialOptions: Black Grills, Reverse Flow Exhaust
Accessories
Part No. Voltage Power Mating Exhaust Filter Ship Wt. lbsPF33000T12LGSL 115V 20W PFA30000LG 4PF33000T12LGSL2 230V 19W PFA30000LG 4PF330DCT12LGSL2 24V DC 5W PFA30000LG 4PF65000T12LGSL 115V 80W PFA60000LG 8PF65000T12LGSL2 230V 80W PFA60000LG 8PF67000T12LGSL 115V 120W PFA60000LG 10PF67000T12LGSL2 230V 127W PFA60000LG 10PF67000T12LGSL4 400V/460V 110W PFA60000LG 10
Airflow data PF 33000 SL PF 65000 SL PF 67000 SLFilter material Type 12 Filtermat Type 12 Filtermat Type 12 FiltermatUnimpeded airflow 297 CFM 462 CFM 560 CFMCooling Dissipation (W)/°T 168 W/K 262 W/K 317 W/KAirfl ow in combination 230 CFM 295 CFM 368 CFM
(Filterfan + Exhaust Filter) (PF 33000 + PFA30000)
(PF 65000 + PFA60000)
(PF 67000 + PFA60000)
Capacity in combination 127 W/K 167 W/K 208 W/K
(Filterfan + Exhaust Filter) (PF 33000 + PFA30000)
(PF 65000 + PFA60000)
(PF 67000 + PFA60000)
Max. static pressure (Airfl ow= 0)
74 Pa 134 Pa 187 Pa
Filtration effi ciency 0.91 0.91 0.91Filter material grade G 4 (DIN EN 779) G 4 (DIN EN 779) G 4 (DIN EN 779)Duty cycle 1 1 1
Technical data PF 33000SL PF 65000SL PF 67000SLOutside dimensions in mm(height x width x installationdepth)
202 x 202 x 87 320 x 320 x 124 320 x 320 x 127
Quality Products. Service Excellence.
DRAFT
www.schneider-electric.us
19P
US
H B
UT
TO
NS
AN
D
OP
ER
AT
OR
INT
ER
FA
CE
© 2009 Schneider ElectricAll Rights Reserved
19-25
22 mm Push Buttons XB4 Complete DevicesRefer to Catalog 9001CT0001
a For 240 V LED, replace the last “B” or “G” in the catalog number with an “M”. For example, XB4BVB1 (24 V) becomes XB4BVM1 (240 V—AC only).
Legends. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 19-37 to 19-39
Table 19.59: Pilot Lights with Protected LED® (screw clamp terminal connections) a
Shape of Head Supply Voltage Color Catalog Number (Components) $ Price
24 Vac/Vdc
White XB4BVB1 (ZB4BVB1 + ZB4BV013)
72.00Green XB4BVB3 (ZB4BVB3 + ZB4BV033)Red XB4BVB4 (ZB4BVB4 + ZB4BV043)
Yellow XB4BVB5 (ZB4BVB5 + ZB4BV053)Blue XB4BVB6 (ZB4BVB6 + ZB4BV063)
110–120 Vac
White XB4BVG1 (ZB4BVG1 + ZB4BV013)
72.00Green XB4BVG3 (ZB4BVG3 + ZB4BV033)Red XB4BVG4 (ZB4BVG4 + ZB4BV043)
Yellow XB4BVG5 (ZB4BVG5 + ZB4BV053)Blue XB4BVG6 (ZB4BVG6 + ZB4BV063)
Table 19.60: Pilot Lights for BA9s Bulb (screw clamp terminal connections)Shape of Head Supply Voltage Color Catalog Number (Components) $ Price
Direct supply, for BA9s (incandescent, LED, neon) V < 250 V, 2.4 W bulb (bulb not included)
< 250 Vac/Vdc
White XB4BV61 (ZB4BV6 + ZB4BV01)
51.00Green XB4BV63 (ZB4BV6 + ZB4BV03)Red XB4BV64 (ZB4BV6 + ZB4BV04)
Yellow XB4BV65 (ZB4BV6 + ZB4BV05)
Transformer type with 1.2 VA, 6 V secondary. BA9s incandescent bulb included
110–120 Vac50/60 Hz
White XB4BV31 (ZB4BV3 + ZB4BV01)
117.00Green XB4BV33 (ZB4BV3 + ZB4BV03)Red XB4BV34 (ZB4BV3 + ZB4BV04)
Yellow XB4BV35 (ZB4BV3 + ZB4BV05)
Table 19.61: Illuminated Push Buttons, Momentary (screw clamp terminal connections) a
Shape of Head DescriptionType of Contact
Supply Voltage Color of Push Catalog Number (Components) $ PriceN.O. N.C.
Flush
1 1
24 Vac/Vdc
White XB4BW31B5 (ZB4BW0B15 + ZB4BW313)
119.00Green XB4BW33B5 (ZB4BW0B35 + ZB4BW333)Red XB4BW34B5 (ZB4BW0B45 + ZB4BW343)
Yellow XB4BW35B5 (ZB4BW0B55 + ZB4BW353)Blue XB4BW36B5 (ZB4BW0B65 + ZB4BW363)
110–120 Vac
White XB4BW31G5 (ZB4BW0G15 + ZB4BW313)
119.00Green XB4BW33G5 (ZB4BW0G35 + ZB4BW333)Red XB4BW34G5 (ZB4BW0G45 + ZB4BW343)
Yellow XB4BW35G5 (ZB4BW0G55 + ZB4BW353)Blue XB4BW36G5 (ZB4BW0G65 + ZB4BW363)
Direct supply for BA9s 2.4 W max. bulb not included
1 1 < 250 Vac/Vdc
White XB4BW3165 (ZB4BW065 + ZB4BW31)
99.00Green XB4BW3365 (ZB4BW065 + ZB4BW33)Red XB4BW3465 (ZB4BW065 + ZB4BW34)
Yellow XB4BW3565 (ZB4BW065 + ZB4BW35)
Transformer type1.2 VA, 6 V secondary.BA9s incandescent bulb included
1 1
110–120 Vac50/60 Hz
White XB4BW3135 (ZB4BW035 + ZB4BW31)
163.00Green XB4BW3335 (ZB4BW035 + ZB4BW33)Red XB4BW3435 (ZB4BW035 + ZB4BW34)
Yellow XB4BW3535 (ZB4BW035 + ZB4BW35)
230–240 Vac50/60 Hz
White XB4BW3145 (ZB4BW045 + ZB4BW31)
163.00Green XB4BW3345 (ZB4BW045 + ZB4BW33)Red XB4BW3445 (ZB4BW045 + ZB4BW34)
Yellow XB4BW3545 (ZB4BW045 + ZB4BW35)
Extended
1 1
24 Vac/Vdc
White XB4BW11B5 (ZB4BW0B15 + ZB4BW113)
113.00Green XB4BW13B5 (ZB4BW0B35 + ZB4BW133)Red XB4BW14B5 (ZB4BW0B45 + ZB4BW143)
Yellow XB4BW15B5 (ZB4BW0B55 + ZB4BW153)Blue XB4BW16B5 (ZB4BW0B65 + ZB4BW163)
110–120 Vac
White XB4BW11G5 (ZB4BW0G15 + ZB4BW113)
113.00Green XB4BW13G5 (ZB4BW0G35 + ZB4BW133)Red XB4BW14G5 (ZB4BW0G45 + ZB4BW143)
Yellow XB4BW15G5 (ZB4BW0G55 + ZB4BW153)Blue XB4BW16G5 (ZB4BW0G65 + ZB4BW163)
XB4BVB5
XB4BV64
XB4BV33
XB4BW33B5
XB4BW3465
XB4BW3545
I Discount Schedule
DRAFT
Altivar™ 212 DriveSelection Guide
Make the most of your energySM
Variable speed drives for asynchronous motors used in centrifugal pump and fan applications
DRAFT
2
Altivar 212 Drive Selection
Altivar 212 Drive Selection
• TheAltivar212driveisintendedforusewiththree-phaseasynchronousmotorsforvariabletorquepumpandfanapplications.• SelecttheAltivar212driveusingthenameplatevoltageandfullloadampereratingofthemotornameplateandthetablebelow.• TheAltivar212driveincludes3logicinputs,2analoginputs,1analogoutputand2relayoutputs(with1NOand1NO/NCcontacts).• Itincludesintegrated4digit,7segmentLEDdispaywith7buttonkeypad,aswellasRJ45Modbus™port,plusa4screwremovableterminal
blockforsoftwareselectableBACnet,Modbus,METASYSN2orAPOGEEP1communicationprotocols.LonWorksisavailableinanoptioncard.
• Thesehorsepower,kWandcontinuousampereratingsapplytodefaultswitchingfrequencyandmaximum40°Cambient.
• Refertotheinstallationmanualforderatingcurvesasafunctionofswitchingfrequency,ambienttemperatureandmountingconditions.
• IP20Altivar212drivescanbeinstalledasULType1withtheoptionalconduitboxwhenfollowinginstructionintheInstallationManual.
• ToselectanAltivar212W...driveswithClassBEMCfilter,addtheletter“C”totheendofthestandardcatalognumber.
• CLate3Q2011availability.
AC Input line voltage
Enclosure rating
Three-phase motor power
Continuous Output current
IP 20Open style product
Type 1 conduit kit (purchase ATV212 and conduit Kit for Type 1 installation)
Type 12/IP54
HP kW A Catalog number QTY Frame size
Catalog number QTY Catalog number C QTY Frame size
208/240Vacthree-phase
1 0.75 4.6 ATV212H075M3X 1 VW3A31814 —
2 1.5 7.5 ATV212HU15M3X 1 VW3A31814 —
3 2.2 10.6 ATV212HU22M3X 1 VW3A31814 —
4 3 13.7 ATV212HU30M3X 2 VW3A31815 —
5 4 18.7 ATV212HU40M3X 2 VW3A31815 —
7.5 5.5 24.2 ATV212HU55M3X 3 VW3A31816 —
10 7.5 32 ATV212HU75M3X 3 VW3A31816 —
15 11 46.2 ATV212HD11M3X 4 VW3A31817 —
20 15 61 ATV212HD15M3X 4 VW3A31817 —
25 18.5 74.8 ATV212HD18M3X 4 VW3A31817 —
30 22 88 ATV212HD22M3X 5 VW3A9206 —
40 30 117 ATV212HD30M3X 7 VW3A9208 —
380/480 Vacthree-phase
1 0.75 2.2 ATV212H075N4 1 VW3A31814 ATV212W075N4 1
2 1.5 3.7 ATV212HU15N4 1 VW3A31814 ATV212WU15N4 1
3 2.2 5.1 ATV212HU22N4 1 VW3A31814 ATV212WU22N4 1
4 3 7.2 ATV212HU30N4 2 VW3A31815 ATV212WU30N4 2
5 4 9.1 ATV212HU40N4 2 VW3A31815 ATV212WU40N4 2
7.5 5.5 12 ATV212HU55N4 2 VW3A31815 ATV212WU55N4 2
10 7.5 16 ATV212HU75N4 3 VW3A31816 ATV212WU75N4 2
15 11 22.5 ATV212HD11N4 3 VW3A31816 ATV212WD11N4 3
20 15 30.5 ATV212HD15N4 4 VW3A31817 ATV212WD15N4 3
25 18.5 37 ATV212HD18N4 4 VW3A31817 ATV212WD18N4 4
30 22 43.5 ATV212HD22N4SC 4 VW3A31817 —
30 22 43.5 ATV212HD22N4 5 VW3A9206 ATV212WD22N4 5
40 30 58.5 ATV212HD30N4 5 VW3A9206 ATV212WD30N4 5
50 37 79 ATV212HD37N4 6 VW3A9207 ATV212WD37N4 6
60 45 94 ATV212HD45N4 6 VW3A9207 ATV212WD45N4 6
75 55 116 ATV212HD55N4 7 VW3A9208 ATV212WD55N4 7
100 75 160 ATV212HD75N4 7 VW3A9208 ATV212WD75N4 7
ATV212HU15N4 ATV212W075N4 ATV212HU55M3X
ATV212HD37N4 ATV212HD37N4ATV212HU30M3X
DRAFT
UL98 IEC Style Disconnect Switches
(1} (2} (3}
8·8
3()...100 A Compact
100-400 A
GS2AH130 GS2AH150 GS2AH170
GS2GU3N
Optional on shafts fOf LK40U3CN. LK4GU3CN and LK4JU3CN. FOf use on s1.itches end·ng v.ilh CN only. 600-1200 A standard v.ilh top shroud.
LK4 Nonfusible and GS2 Fusible Disconnect Switches
Refer to Catalog 9421CT0301
l-+·llfJ;Iijol by Schneider Ele-ccrlc
schnelder-etectric.u s
LK4 Nonfusible Disconnect Switches Table 8.28: LK Nonfusible IEC Style Disconnect Switches
Table 8.29: Handles and Shafts for LK Switches I
Handle
Table 8.30: Auxiliary Contacts for LK Switches
Short Circuit Current Rating 600Vac
LK4AEAH t 2CN
GS2AE21
GS2AE61
AL
B
0
Switch Amperes Cata1ogNo. Description ·:-. • • • • MOSAN1t Aux Contact 1 N.D. and 1 N.C. MDSAN20 Aux Contact 2 N.D. and 2 N.C.
100-400 LK4ADtON Aux Cor tact 1 N.D . and 1 N.C. 100-400 LK4AD20N Aux Cortact 2 N.D. and 2 N.C.
600-1200 LK4AD30N Aux Cor tact Holder 600-1200 GS2AM 11 0 Aux Contact 1 N.D. 600-1200 GS2AM101 Aux Contact 1 N.C.
Table 8.31: Terminal Shrouds for LK Switches fiSwitch Amperes Description
3(}-6() LK4AP3CN Shroud Top and Bollom. 3-Po!e
100-200 LK4AP33TN Shroud Top LK4, 3-Pole, 1001200 A
100-200 LK4AP33BN Shroud Bottom LK4, 3-Pole. 1001200 A 400 LK4AP53TN Shroud Top LK4, 3-Pole, 400 A
400 LK4AP53BN Shroud Botlom LK4, 3·Pole, 400 A 600(3} LK4APS3N Shroud Bollom LK4. 3·Pole, 600 A
600-1200 (3} LK4AP83N Shroud Bollom LK4, 3·Pole, 800-1200 A
GS2 Fusible Disconnect Switches Table 8.32: GS Fusible IEC Style Disconnect Switches
Short Circuli Current Rallng
600Vac
© 2015 S<:hneider Electric Nl Rights Reserved
DRAFT
UL98 IEC Style Disconnect Switches Accessories, LK4 Nonfusible and GS2 Fusible
Refer to Catalog 9421CT0301
f+·l'fJ;I§Iol
[B)
8·10
Terminal Lugs
Handle Part No. LK4AHI10CN LK4AH120CN LK4AH410CN LK4AH420CN
Cannot be used on GS2JU3N.
by Schneider Eleodc
schnelder-electric.us
Accessories Table 8.39: Terminal Lugs
Table 8.40: Power Distribution Lugs GS1 or GS2 Only
LK4DU3CN and LK4GU3CN, 30- 100 A Compact Nonfusible Disconnect Switches
Handle for 30-100 A Compact Nonfusible Disconnect Switches Right-side or
front operation
yl o LL_+__J.~~ _
I I I I I l l
4J
Door dri lling with 4 fixing screws
01.22 - lef31
Door drilling with fixing nut
© 201 5 Schneider Electric All Rights Reserved
DRAFT
(}·IIPJ;jjDI LK4 Nonfusible and GS2 Fusible Disconnect Switches
UL98 IEC Style Disconnect Switches
by Schneider El u t rlc
schnelder-electric.us Refer to Catalog 9421 CT0301
GS2AH tt0 GS2AH130
•, ,
Auxiliary Contacts GS1AD10 + GS2AM110
GS2AH150
Table 8.33: Handles and Shafts for GS Switches f4J •• GS2AE8
GS2AE2
GS2AE5
GS2AE8t
GS2AE21
GS2AE5 t
LKN4AEA· H12C
NOTE: Hole adapter kit for GS1 to GS2 Handles: GS2AH1 00T0 200.
Table 8.34: Auxiliary Contacts for GS Switches f5J Description
GS1At.l110 Aux Contact 1 N.O. GS1AM101 Aux Contact 1 N.C.
30 GS1AD10 Aux Contact Holder
Table 8.35: Shorting Links For use on: Shorting Links per Kit Catalog No.
GS2, 60A 3 GS1AU203 GS2. tOO A 3 GS1AU303 GS2, 200A 3 GS1AU403 GS2, 400A 3 GS1AU503 GS2, 6()(H!()() A 3 GS1AU803
Table 8.36: NFPA79 Kit
AG
B
c
GS203N NFPA 791ntemal Handle Kit400 A S\\Hch Shaft GS2AD040N
Shorting Links
GS2GU3N, GS2GLU3N, GS2JU3N, GS2JLU3N GS1DDU3, GS1DU3
NFPA 791ntemal Handle Kit60-200 A S•1.itch Shaft GS2AD030N
NFPA 79 1ntemal Handle I<Jt for 5 mm Shafts GS1AD010
Table 8.37: Terminal Shrouds for GS Switches, Line or Load f6J SY.itch Amperes Catalog No. Description
30-100 Standard on product
200 GS2AP43 GS2, 3-Pole, 200 A
400 GS2AP53 GS2, 3-Pole, 400 A
GS2AP73 GS2, 3-Pole, 6()(H!()() A
New} Cable Operator Kits for GS2 Switches Table 8.38: Cable Operator Kits for GS2 Switches 171
;_. ' .. 1 ' I .
. i·, .j:!: .. ~ Flange Handle
Cable Operator Kit
{4) GS2AH100T02oo-GS11o GS2 Handle Adapter if us'ng GS1 holes.
Catalog No. Description
GSAH36F 38 in. Cable Operator Kits for GS2 S'.\Hches
GSAH60F 60 in. Cable Operator Kits for GS2 S'.'..itches
GSAH120F 120 in. Cable Operator Kits for GS2 S\•.itches
GSAH144F 144 in. Cable Operator Kits for GS2 S\•.itches
GSAH180F 180 in, Cable Operator Kits for GS2 s,•,itches
(5) GS1DU3 and GS1DDU3 S\•.itches allow up lo 4 auxiliary contacts\\ithout adding contact holder GS1AD10. For more than 4 contacts, GS1AD10 is requ'red. {6) Order one terminal shroud per s!de. For example, order one terminal shroud for
either the fine side or load side; order two terminal shrouds for bolh the l ine sX:le and load s'de.
{7) Compatible ,•,i th GS $\\itches up to 200 A. Does not indude handle. For Handle, see Table 1.43.
©2015 Schneider Electric All Rights Reserved
8·9
DRAFT
19-24 © 2009 Schneider ElectricAll Rights Reserved
www.schneider-electric.us
19P
US
H B
UT
TO
NS
AN
D
OP
ER
AT
OR
INT
ER
FA
CE
22 mm Push Buttons XB4 Complete DevicesRefer to Catalog 9001CT0001
a Trigger action mushroom heads are tamper proof in that a change of contact state is not possible by teasing or floating the operator. For emergency stop applications, always use a trigger action push button (per EN/IEC 13850).
Note: The symbol indicates key withdrawal position(s).
b See page 19-29 for contact configurations.
Legends . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 19-37 to 19-39
Table 19.57: Non-Illuminated Emergency Stop and Emergency Off Mushroom Head Push Buttons, Ø 40 mm, Red (screw clamp terminal connections)
Shape of Head Type of Push
Type of ContactCatalog Number (Components) $ Price
N.O. N.C.
Trigger actionpush-pulla 1 1 XB4BT845 (ZB4BZ105 + ZB4BT84) 101.00
Trigger action turn-to-releasea
1 1 XB4BS8445 (ZB4BZ105 + ZB4BS844)165.00
1 2 XB4BS84441 (ZB4BZ141 + ZB4BS844)
Trigger action Key release a(No. 455)
1 1 XB4BS9445 (ZB4BZ105 + ZB4BS944) 165.00
Push-pull — 1 XB4BT42 (ZB4BZ102 + ZB4BT4) 68.00
Turn-to-release — 1 XB4BS542 (ZB4BZ102 + ZB4BS54) 110.00
Key release (No. 455) — 1 XB4BS142 (ZB4BZ102 + ZB4BS14) 147.00
Table 19.58: Non-Illuminated Selector Switches and Key Switches (screw clamp terminal connections)b
Shape of Head Type of Operator
Type of Contact Number and Type of Positions Catalog Number (Components) $ Price
N.O. N.C.
Standard lever, black
1 — 2-maintained XB4BD21 (ZB4BZ101 + ZB4BD2) 51.00
1 1 2-maintained XB4BD25 (ZB4BZ105 + ZB4BD2) 68.00
2 —
3-maintained XB4BD33 (ZB4BZ103 + ZB4BD3) 68.00
3-momentary to center XB4BD53 (ZB4BZ103 + ZB4BD5) 75.00
Extended lever, black
1 — 2-maintained XB4BJ21 (ZB4BZ101 + ZB4BJ2) 51.00
2 —
3-maintained XB4BJ33 (ZB4BZ103 + ZB4BJ3) 68.00
3-momentary to center XB4BJ53 (ZB4BZ103 + ZB4BJ5) 75.00
Key (No. 455)
1 —
2-maintained
XB4BG21 (ZB4BZ101 + ZB4BG2) 123.00
XB4BG41 (ZB4BZ101 + ZB4BG4) 123.00
2-momentary to left XB4BG61 (ZB4BZ101 + ZB4BG6) 123.00
2 — 3-maintained
XB4BG03 (ZB4BZ103 + ZB4BG0) 141.00
XB4BG33 (ZB4BZ103 + ZB4BG3) 141.00
XB4BT845
XB4BS9445
XB4BS542
XB4BG33
XB4BD33
XB4BJ33
I Discount Schedule
DRAFT
6-11
QO® Circuit BreakersClass 685, 690, 730, 912, 950
6C
IRC
UIT
BR
EA
KE
RS
© 2003 Schneider ElectricAll Rights Reserved9/8/03
www.SquareD.comFor the most up-to-date information
Plug-On Circuit Breakers—UL Listed Amperes Interrupting Rating (AIR) In Amperes RMS Symmetrical
1-pole QO-AFI 1-pole
QO-GFI2-pole
QO-GFITwo-wire QO-SWN
Three-wire QO-SWN QO
1-poleWith Shunt Trip
QO-K Key Operated
QO-HM High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications.
AmpereRatinga
1-pole
Catalog No Price
120 Vac—10,000 AIR
15 QO115HMcd $20.4020 QO120HMcd 20.40
QO-AFI QO Circuit Breakers with arc fault protection in accordance with UL1699.
Ampere Rating
a
1-pole 120 Vac 1-pole 120 Vac
10,000 AIR 22,000 AIR
1 Space Required 1 Space Required
Catalog No. Price Catalog No. Price
15 QO115AFId $160. QO115VHAFId $331.
20 QO120AFId 160. QO120VHAFId 331.
QO-GFI Qwik-Gard® circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping.
AmpereRatinga
Qwik-Gard Circuit BreakersWith Ground Fault Circuit Interrupter
1-pole120 Vac
2-pole Common Trip120/240 Vac
10,000 AIR 22,000 AIR 10,000 AIR
1 Space Required 1 Space Required 2 Spaces Required
Catalog No. Price Catalog No. Price Catalog No. Price
15 QO115GFI $155. QO115VHGFI $321. QO215GFI $275.20 QO120GFI 155. QO120VHGFI 321. QO220GFI 275.25 QO125GFI 155. QO125VHGFI 321. QO225GFI 275.30 QO130GFI 155. QO130VHGFI 321. QO230GFI 275.40 . . . . . . . . . . . . . . QO240GFI 275.50 . . . . . . . . . . . . . . QO250GFI 275.60 . . . . . . . . . . . . . . QO260GFIb 275.
QO-EPD QO-EPD circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 milliampere level. They are not designed to protect people from electrical shock.
AmpereRatinga
1-pole120 Vac
2-pole Common Trip120/240 Vac
10,000 AIR 10,000 AIR
1 Space Required 2 Spaces Required
Catalog No. Price Catalog No. Price
15 QO115EPD $273. QO215EPD $440.20 QO120EPD 273. QO220EPD 440.25 QO125EPD 273. QO225EPD 440.30 QO130EPD 273. QO230EPD 440.40 . . . . . . . QO240EPD 440.50 . . . . . . . QO250EPD 440.60 . . . . . . . QO260EPDb 440.
QO-SWN Switch Neutral Common Trip 2002 NEC® 514.11
AmpereRatinga
2 Wire 120 Vac 3 Wire 120/240 Vac
10,000 AIR 10,000 AIR
2 Spaces Required 3 Spaces Required
Catalog No. Price Catalog No. Price
10 QO210SWN $63. QO310SWN $95.15 QO215SWN 63. QO315SWN 95.20 QO220SWN 63. QO320SWN 95.25 QO225SWN 63. QO325SWN 95.30 QO230SWN 63. QO330SWN 95.40 QO240SWN 63. QO340SWN 95.50 QO250SWN 63. QO350SWN 95.
a 10–30 ampere breakers are suitable for use with 60°C or 75°C conductors. 35–60 ampere circuit breakers are suitable for use with 75°C conductors.
b Suitable only for feeding 240 Vac and 208 Vac 2 wire loads. Does not contain load neutral connection.
c UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
d UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers.
Non-automatic (Standard) Miniature Switches
Miniature non-automatic switches have the same physical packaging as miniature circuit breakers, but open only when the handle is switched to the OFF position.
Non-automatic switches provide no overcurrent protection or short circuit protection. They must not be used on systems that have an available fault current greater than the values listed in the table.
Non-automatic switches are UL Listed per UL 1087 and are CSA certified.
Non-automatic Miniature Switches, 240 Vac 10 kA
QO-HID QO-HID Circuit BreakersHID circuit breakers are for use on circuits feeding fluorescent and high intensity discharge (HID) lighting systems such as mercury vapor, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QO circuit breakers.
AmpereRatinga
1-pole120/240 Vac
2-pole Common Trip120/240 Vac
3-pole Common Trip240 Vac
10,000 AIR 10,000 AIR 10,000 AIR
1 Space Required 2 Spaces Required 3 Spaces Required
Catalog No. Price Catalog No. Price Catalog No. Price
15 QO115HIDc $25.40 QO215HID $58.00 QO315HID $200.0020 QO120HIDc 25.40 QO220HID 58.00 QO320HID 200.0025 QO125HID 25.40 QO225HID 58.00 QO325HID 200.0030 QO130HID 25.40 QO230HID 58.00 QO330HID 200.0040 QO140HID 25.40 QO240HID 58.00 . . . . . . .50 QO150HID 25.40 QO250HID 58.00 . . . . . . .
QO-K Key operated QO circuit breakers are available in single-pole construction and can be mounted in any single-pole space which will accept a standard QO. These circuit breakers can be turned ON or OFF or to RESET with a special key (Catalog No. QOK10) included with the circuit breaker. These circuit breakers are UL Listed and available as shown in the table.
120 Vac—10,000 AIR (1 Space Required)
Ampere Ratinga
Catalog No. Price
10 QO110K $109.15 QO115K 109.20 QO120K 109.25 QO125K 109.30 QO130K 109.
AmpereRating
2-pole 3-pole
Catalog No. Price Catalog No. Price
60 QO200 $ 46.90 QO300 $165.00100 QO2000 133.00 QO3000 244.0060 QOU200 58.00 QOU300 190.00
100 QOU2000 164.00 QOU3000 277.00125 QOU20001 302.00 QOU30001 477.00
9/8/03
DE2A DiscountSchedule
DRAFT
7-14 © 2009 Schneider ElectricAll Rights Reserved
www.schneider-electric.us
7M
INIA
TU
RE
AN
D M
OL
DE
D C
AS
E
CIR
CU
IT B
RE
AK
ER
S
QO® and QOU Miniature Circuit Breakers
QOU Miniature Circuit Breakers and QYU Supplementary ProtectorsClass 720 / Refer to Catalog 0730CT9801
Low Ampere QOU Miniature Circuit BreakersQOU unit mount miniature circuit breakers (cable-in/cable-out) are ideal for OEM applications. They have Square D’s unique Visi-Trip® feature and can be DIN rail-mounted or surface- or flush-mounted using mounting feet.
a QOU-H interrupting rating is 10 kA at 240 Vac.
High Ampere QOU Circuit Breakers
Interrupting Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-3Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-12, 7-15Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7-54
General Specifications Common to All Low Ampere QOU Circuit Breakers
• For convenient flush mount, surface mount or DIN mount (symmetrical rail 35 x 7.5 DIN/EN 50 022)
• Single handle with internal common trip• Terminal lug wire size (1) 14–2 AWG Cu or Al• Reversible line and load lugs• Field-installable quick connectors
• UL Listed 48 Vdc (5 k AIR)• UL Listed as HACR Type—10–70 A• High magnetic trip circuit breakers (QOU-HM) are recommended
for applications where high initial inrush may occur and forindividual dimmer applications.
• For DIN mounting rails, see IEC Starters and Relays, Section 18
Table 7.20: QOU Low Ampere Miniature Circuit Breakers
Ampere Rating
1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac
Cat. No. $ Price Cat. No. $ Price Cat. No.a $ Price Cat. No. $ Price
10 k AIR
10 A QOU110
40.20
QOU210
87.00
—
168.00
QOU310
285.00
15 A QOU115 QOU215 QOU215H QOU31520 A QOU120 QOU220 QOU220H QOU32025 A QOU125 QOU225 QOU225H QOU32530 A QOU130 QOU230 QOU230H QOU33035 A QOU135 QOU235 — — QOU33540 A QOU140 QOU240 — — QOU34045 A QOU145 QOU245 — — QOU34550 A QOU150 QOU250 — — QOU35060 A QOU160 QOU260 — — QOU36070 A QOU170 78.00 QOU270 171.00 — — QOU370 363.00
22 k AIR
15 A QOU115VH
101.00
QOU215VH
189.00
— — QOU315VH
426.0020 A QOU120VH QOU220VH — — QOU320VH25 A QOU125VH QOU225VH — — QOU325VH30 A QOU130VH QOU230VH — — QOU330VH35 A QOU135VH QOU235VH — — — —40 A QOU140VH QOU240VH — — — —45 A QOU145VH QOU245VH — — — —50 A QOU150VH QOU250VH — — — —60 A QOU160VH QOU260VH — — — —
Table 7.21: QOU-HM Miniature Circuit Breakers (10 k AIR)
Ampere Rating
1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
15 A QOU115HM40.20
— — — — — —20 A QOU120HM — — — — — —
Table 7.22: QYU UL1077 Recognized Supplementary Protectors (5 k AIR)
Ampere Rating
1P 277 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
10 A QYU110
122.00
— — — — — —15 A QYU115 — — — — — —20 A QYU120 — — — — — —25 A QYU125 — — — — — —30 A QYU130 — — — — — —
General Specifications Common to All High Ampere QOU Circuit Breakers
• Flush mount, surface mount, and DIN rail mount.• Internal common trip.• Non-reversible line and load lugs.• Terminal lug wire size (1) 12– 2/0 AWG Cu or Al.• UL Listed 60 Vdc per pole (5 k AIR). (Note: except switches)
• UL Listed as HACR type, 80–125 A.• Non-automatic switches have the same physical packaging
as miniature circuit breakers, but provide no overcurrent orshort circuit protection. They are UL Listed per UL1087 andare CSA certified.
Table 7.23: QOU High Ampere Miniature Circuit Breakers (10 k AIR)
Ampere Rating
1P 120/240 Vac 2P 120/240 Vac 2P 240 Vac 3P 240 Vac
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price
80 A QOU180176.00
QOU280246.00
— — QOU380416.0090 A QOU190 QOU290 — — QOU390
100 A QOU1100 QOU2100 — — QOU3100125 A — — QOU2125 452.00 — — — —
Table 7.24: QOU Non-Automatic Switches
Ampere Rating
1P 120 Vac$ Price
2P 120/240 Vac$ Price
2P 240 Vac $ Price
3P 240 Vac$ Price
Cat. No. Cat. No. Cat. No. Cat. No.
60 A — — — — QOU200 87.00 QOU300 285.00100 A — — — — QOU2000 246.00 QOU3000 416.00125 A — — — — QOU20001 452.00 QOU30001 716.00
Low Ampere QOU
High Ampere QOU
DE2 Discount Schedule
DRAFT
Product Data Sheet RPM12F7PLUG-IN RELAY 250V 15A RPM +OPTIONS
List Price $5.30 USD
Availability Stock Item: This item is normally stocked in our distribution facility.
Contact Arrangement SPDT
Contact Rating (NEMA) B300
Relay Type Power
Description (Individual) Ice Cube Relays / SPDT, 15 Amp Rating
Electrical Connection Flat/Spade (Faston Type)
Mounting Style Plug-In Socket (DIN rail or Flange with adapter)
Contact Configuration 1 NO/1 NC
Contact Materials Silver Alloy (AgNi)
Coil Voltage 120 VAC
Coil Resistance 4430 Ohms
Average Consumption 0.9 VA
Drop-out Voltage Threshold 0.15 Uc
Rated Operational Current (IEC) 15A (NO) - 7.5A (NC)
Rated Operational Current (UL) 15A
Switching Capacity (Minimum) 10mA@17V
Switching Capacity (Maximum) 3750 VA
Horsepower Rating 0.5HP@120VAC
Conventional Thermal Current 15A
Maximum Switching Voltage 250V
Rated Insulation Voltage 300V (UL & CSA) - 250V (IEC)
Nominal Load (Resistive) 15A@250VAC - 15A@28VDC
Mechanical Durability 10 million operating cycles
Certifications UL Listed - CSA Certified - CE Marked - RoHS Compliant
Electrical Durability (Resistive Load) 0.1 million operating cycles
Operating Time (Response Time) (NO) AC: 20ms DC: 20ms (NC) AC: 20ms DC: 20ms
Type RPM
Lockable Test Button Yes
LED Indicator Yes
Dielectric Strength - Between Coil and Contact 1550 VAC
Ambient Air Temperature (Operation) -40 to 131°F (-40 to 55°C)
Specifications Sold in lots of 10
Dielectric Strength - Between Poles 1550 VAC
Shock Resistance 15g (opening) 15g (closing)
Technical Characteristics
Generated: 07/02/2012 17:08:00
© 2012 Schneider Electric. All rights reserved.
1
DRAFT
Maximum Operating Rate (Under Load) 1200 operating cycles/hour
Dielectric Strength - Between Contacts 1500 VAC
Degree of Protection IP 40 conforming to IEC/EN 60529
Maximum Operating Rate (No Load) 18000 operating cycles/hour
Ambient Air Temperature (Storage) -40 to 185°F (-40 to 85°C)
Weight 0.05 lbs (0.024kg)
Rated Impulse Withstand Voltage 3.6 kV
Category 21127 -
Discount Schedule CP2
GTIN 00785901447795
Package Quantity 10
Weight 0.05 lbs.
Availability Code Stock Item: This item is normally stocked in our distribution facility.
Returnability Y
Country of Origin CN
Shipping and Ordering
As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document.
Generated: 07/02/2012 17:08:00
© 2012 Schneider Electric. All rights reserved.
2