spec ep10kva - 60kva

1
Technical Specification Model SIN10KEP SIN20KEP SIN30KEP SIN40KEP SIN60KEP Capacity ( VA ) 10 kVA 20 kVA 30 kVA 40 kVA 60 Kva Power Rating ( W ) 9 kW 18 kW 27 kW 39 kW 54 kW Input Voltage range ( 380Vac / 400Vac / 415Vac ) ±25% three-phase Frequency range 50 / 60 Hz ±5Hz auto-sensing Power factor > 0.8 ( without filter ) Rated current 15A 30A 45A 60A 90A Output Voltage range 380Vac ( or 400Vac / 415Vac ) ±1% Frequency Auto-sensing the input frequency Frequency regulation ( battery mode ) 50 Hz / 60Hz ±0.05% Output waveform Sine wave Power factor 0.9 ( lagging ) Distortion Linear load <3%, Non-linear <5% Overload capacity When 110% / 125% / 150% overload, maintain 60min / 10min / 1min Crest factor 3 : 1 ( max ) Efficiency 88% 89% 90% 90% 91% Transfer time Line mode → Battery mode 0 ms Bypass Rated voltage 380 / 400 / 415 Vac Bypass voltage range Upper limit: +10%, +15%, +20% can be set Lower limit: -10%, -20%, -30%, -40% can be set Rated frequency 50 / 60 Hz ( auto-sensing ) Bypass frequency range ±2% (±10%, ±20% can be set ) Transfer time to bypass 0 ms / 1 ms Overload capacity 15 times the rated current ( 10ms ), 5 times the rated current ( 5s ) Battery Battery voltage ( VDC ) 384 Panel display LED Indicate the status of input, inverter, bypass, battery, output LCD Display input/ output voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage, UPS status, history record, set parameters Environment Communication interface Dry contact RS232, RS485, SNMP card Operating temperature 0 ~ 40 0 C Humidity 0 ~ 95% Non-condensing Storage temperature -25 0 C ~ 55 0 C Noise ( 1m away from the unit ) <65 dB <68 dB Physical characteristics Net ( Kg ) 217 273 316 330 485 Gross ( Kg ) 272 328 371 385 553 Dimension ( W x D x H ) mm 570*800*1220 800*740*1600 Options Harmonic filter, SNMP adapter, LBS cable, battery temperature sensor, battery ground fault detection, bypass current sharing inductor. Satisfy the international EMC safety requirements EMI IEC62040-2: output requirements of EMC on UPS ( >16A ) EMS IEC61000-4-2(ESD): Anti-electrostatic discharge IEC61000-4-3(RS): Anti-interference of radiation IEC61000-4-4(EFT): Anti-interference of power pulse IEC61000-4-5(Surge): Anti-lightning/ surging Industry standard CE, EN/IEC 62040-2, EN/IEC 62040-1-1 Specifications are subject to change without prior notice CONTACT PERSON :

Upload: dian-andriana

Post on 18-Dec-2015

29 views

Category:

Documents


11 download

DESCRIPTION

it

TRANSCRIPT

  • Technical Specification

    Model SIN10KEP SIN20KEP SIN30KEP SIN40KEP SIN60KEP Capacity ( VA ) 10 kVA 20 kVA 30 kVA 40 kVA 60 Kva Power Rating ( W ) 9 kW 18 kW 27 kW 39 kW 54 kW Input Voltage range ( 380Vac / 400Vac / 415Vac ) 25% three-phase Frequency range 50 / 60 Hz 5Hz auto-sensing Power factor > 0.8 ( without filter ) Rated current 15A 30A 45A 60A 90A Output Voltage range 380Vac ( or 400Vac / 415Vac ) 1% Frequency Auto-sensing the input frequency Frequency regulation ( battery mode ) 50 Hz / 60Hz 0.05% Output waveform Sine wave Power factor 0.9 ( lagging ) Distortion Linear load