d PowerFluHK.66.B1.02
Spreader Valves Fluid Power
HK.66.B1.02 Danfoss Fluid Power 10/93
Fluid Power
2
Introduction
Spreader Valves
GeneralFluid Controls is the worlds largest manufacturer of spreadercontrol valves, and has provided the market with a wide variety ofoptions. The primary use is ice and snow control for many city,county and township sand/salt spreader vehicles. Valves havealso been applied on many agricultural fertilizer spreadersystems, as well as construction paving equipment.
Fluid Controls Spreader valves can provide:• Single compact body permitting easy installation.• Manual or remote electrical control.• Load sensing capability.• Single or dual control.• Pressure compensation.• Gasket mounted configurations
Types and Operation
Type Description Symbol Models Page
Flow regulator, adjustable and pressurecompensated, with manual on/unload controland relief.
Single ManualControl Spreader 2FL12 3
Flow regulator, adjustable and pressurecompensated, with solenoid on/unload controlwith relief.
Single ControlSpreader withSolenoid Unload
2FLW86 4
Dual flow regulator, adjustable and pressurecompensated.
Dual ControlSpreader
2FF12 5
2FFC12 6Dual flow regulator, adjustable and pressurecompensated, with load sensing.
Dual Control LoadSensing Spreader
2FFLC12 7
Dual flow regulator, adjustable and pressurecompensated, with manual on/unload control andwith load sensing.
Dual ControlManual LoadSensing Spreader
Dual flow regulator, adjustable and pressurecompensated, with manual on/unload controland relief.
2FFL12 8Dual ControlManual Spreader
Dual flow regulator, adjustable and pressurecompensated, with solenoid on/unload controland relief.
Dual ControlSpreader withSolenoid Unlod
2FFLW86 9
Dual flow regulator, adjustable and pressurecompensated, with solenoid on/unload control, reliefand load sensing.
Dual ControlRemote LoadSensing Spreader
2FFCW12 10
Fluid Power
HK.66.B1.02 Danfoss Fluid Power 10/93 3
Single Flow Regulator, Adjustable and Pressure Compensated,with Manual On/Unload Control and Relief
Max inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar
Specifications• To 150 bar.• Inlet flow to 150 l/min.• Regulated flow to 115 l/min.• Weight: 2,90 kg.
Features• Honed and matched hardened steel
working parts for long life.• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob
with min. & max. stops. 11 positive,easy to adjust positions.
• Fully pressure compensated.• On/unload lever control with detented
stops.• 100% performance tested.
Use and OperationFor use with fixed displacement pumpsin circuits that require a single pres-surecompensated flow control, manualon/ unload and pump relief. Ideal forspeed control of an actuator whichmust have a specific flow setting.Typical machinery applications include
agricultural equipment, salt and cinderspreaders and paving machinery.The valve maintains constant regulatedflow even with changes in loadpressure or input flow. The pressurecompensated regulating sectionbypasses excess pump flow to tank.The tank or bypass port must bereferenced directly to tank and not to aworking line. The direct acting reliefvalve senses system pressure andprotects the pump from shock oroverload pressure surges. The built-inlever operated two-way valve unloadssystem flow to tank. This allows on-unload control of regulated flow withoutchanging the flow setting. In the unloadcondition a 4,5 bar check valve may berequired in the »A« port, »T« port orboth to reduce the potential of motormovement.
Materials• Body – High-strength aluminium
alloy.• Internal parts – Hardened steel.• Seals – Viton A standard.
Performance curve
How to order
Adjust. MeansD = Detented
Hand Knob
Regulated Flow Range10 = 38 l/min15 = 57 l/min20 = 76 l/min30 = 115 l/min
Base Part No. Port Size6 = 3/4" NPTF
6W = G 3/4
2FL12 - D 6 - 20 SV
SealsSV = Viton A
P
T
A
Cartridge and Parts in Body 2FL12
Typical spreader circuit
●P
●
●T
A
≈ 206
108,0 1L10Cartride
≈ 106
63,5
Unload
On
121,2 ∅ 7,1
80,3
5,8
5,8
63,5
88,9
15,8
42,9
95,8
101,6
≈ 132
T
P
A
Regulated flow versushand knob detent positions
HK.66.B1.02 Danfoss Fluid Power 10/93
Fluid Power
4
Performance curve
How to order
Regulated flow versushand knob detent positions
Single Flow Regulator, Adjustable and Pressure Compensated,with Solenoid On/Unload Control and Relief
Max inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar
Cartridges and Parts in Body 2FLW86
Specifications• To 140 bar.• Inlet flow to 150 l/min.• Regulated flow to 115 l/min.• Weight: 2,90 kg.
Features• Honed and matched hardened steel
working parts for long life.• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob
with min. & max. stops. 11 positive,easy to adjust positions.
• Fully pressure compensated.• 100% performance tested.
Use and OperationFor use with fixed displacement pumpsin circuits that require a single pressurecompensated flow control, solenoidvalve for on-unload and pump relief.Ideal for speed control of an actuatorwhich must have a specific flow setting.Typical machinery applications includeagricultural equipment, salt and cinderspreaders and paving machinery.
The valve maintains constant regulatedflow even with changes in loadpressure or input flow. The pressurecompensated regulating sectionbypasses excess pump flow to tank.The pump operates at load pressureplus control section pressure drop. Thetank or bypass port must be referenceddirectly to tank and not to a workingline. The direct acting relief valvesenses system pressure and protectsthe pump from shock or overloadpressure surges. The built-in solenoidoperated two-way valve unloadssystem flow to tank. In the unloadcondition a 4,6 bar check valve may berequired in either the »A« port, the »T«port or both ports to reduce thepotential of motor movement. Thisallows on/unload control of regulatedflow without changing the flow setting.
Materials• Body – High-strength aluminium
alloy.• Internal parts – Hardened steel.• Seals – Viton A standard.
Base Part No. Regulated Flow Range10 = 38 l/min15 = 57 l/min20 = 76 l/min30 = 115 l/min
Adjust. MeansD= Detented
Hand Knob
2FLW86 - D 6 - 20 SV
Port Size6 = 3/4" NPTF6W= G 3/4
SealsSV = Viton A
Typical spreader circuit
●
●T
REG
●P ●A
≈ 240
63,51L10Cartridge
7W20Solenoid
≈ 105
115,15,8
≈ 138
15,8
42,9
108,0
80,3
5,8
∅ 7,1
89,7
63,5
127,0
T
P
REG.
88,9
REG
P
T
A
Fluid Power
HK.66.B1.02 Danfoss Fluid Power 10/93 5
Performance curve
P T
A
S
Parts in Body 2FF12
Dual Flow Regulator, Adjustable and Pressure Compensated
Max inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar
Typical spreader circuit
●P
●A
●S
●T
≈ 106
63,5
11,2127,0
≈ 149
121,2∅ 7,1
108,0
101,6
95,842,9
15,8
88,9
63,5
38,1
80,3
5,8
T
P
AS
Specifications• To 140 bar.• Inlet flow to 150 l/min.• Regulated flow to 115 l/min.• Weight: 2,90 kg.
Features• Honed and matched hardened steel
working parts for long life.• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob
with min. & max. stops. 11 positive,easy to adjust positions.
• Fully pressure compensated.• 100% performance tested.
Use and OperationFor use with fixed displacement pumpsin meter in circuits that require two
pressure compensated flow controls.Ideal for use with a directional controlvalve that has a built-in system reliefand for speed control of two actuatorswhich must have individual flowsettings.The valve maintains constant regulatedflow to two actuators even with changesin load pressure or input flow. Thepressure compensated regulatingsection bypasses excess pump flow totank. The tank or bypass port must bereferenced directly to tank and not to aworking line.
Materials• Body – High-strength aluminium
alloy.• Internal parts – Hardened steel.• Seals – Viton A standard.
Regulated flow versushand knob detent positions
How to order
2FF12 - D 6 - 5/15 SV
Adjust. MeansD= Detented
Hand Knob
Base Part No. SealsSV =Viton A
Regulated FlowRanges S (Spinner)5 = 0-19 l/min
10 = 0-38 l/min
Regulated FlowRanges A (Auger)15 = 0- 57 l/min30 = 0-115 l/min
Port Size6 = 3/4" NPTF6W = G 3/4
HK.66.B1.02 Danfoss Fluid Power 10/93
Fluid Power
6
≈ 106
63,5
12,7
12,7
5,8
≈ 145
127,0
115,1
88,9
63,5
30,0
∅ 7,1
≈ 117
108,0
69,3
38,1
89,7
L A
S
P
A
L
S
P
Dual Flow Regulator, Adjustable and Pressure Compensated, with Load Sensing
To 150 I/min and 210 bar
Typical spreader circuit
Specifications• To 210 bar.• Inlet flow to 150 l/min.• Regulated flow to 57 l/min.• Weight: 2,86 kg.
Features• Internal load sensing checks to
communicate pressure signals to loadsensing pump.
• Honed and matched hardened steelworking parts for long life.
• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob
with min. & max. stops. 11 positive,easy to adjust positions.
• Fully pressure compensated.• 100% performance tested.
Use and OperationFor use with variable displacement,pressure compensated pumps in loadsensing circuits that require twopressure compensated flow controls.Ideal for use with solenoid controlleddirectional valves and for speed controlof two actuators which must haveindividual flow settings.This valve maintains constant regulatedflow to two actuators even with changesin load pressure. The »L« port sensesthe load pressure on both actuators andsignals the pump to increase ordecrease the supply flow.
MATERIALS• Body – High-strength aluminium
alloy.• Internal parts – Hardened steel.• Check component – Hardened
steel balls.• Seals – Viton A standard.
2FFC12 - D 6 - 7/15 SV
Regulated FlowRanges (Auger)15 = 0-57 l/min
Regulated FlowRanges (Spinner)5 = 0-19 l/min7 = 0-26,5 l/min
10 = 0-38 l/min
Port Size6 = 3/4" NPTF (P & A)
1/2" NPTF (S)1/4" NPTF (T)
Adjust MeansD= Detented
Hand Knob
Base Part No. SealsSV =Viton A
●P
Performance curve
Parts in Body 2FFC12
How to order
Regulated flow versushand knob detent positions
●A
●L
●S
Fluid Power
HK.66.B1.02 Danfoss Fluid Power 10/93 7
Performance curve
Parts in Body 2FFLC12
Dual Flow Regulator, Adjustable and Pressure Compensated,with Manual On/Unload Control and Load Sensing
To 150 I/min and 210 bar
A
L
S
P
T
A
L
SP
T
Typical spreader circuit
6,4 76,2 12,7
25,4
88,9
∅ 7,1
6,481,0
111,0
49,322,1
52,319,1
A L
P
T
S
6,4
≈ 151
76,2
152,4
≈ 178
Specifications• To 210 bar.• Inlet flow to 150 l/min.• Regulated flow to 115 l/min.• Weight: 3,08 kg.
Features• Internal load sensing checks to
communicate pressure signals to loadsensing pump.
• Honed and matched hardened steelworking parts for long life.
• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob
with min. & max. stops. 11 positive,easy to adjust positions.
• Fully pressure compensated.• On/Unload lever control with detented
stops.• 100% performance tested.
Use and OperationFor use with variable displacement,pressure compensated pumps in loadsensing circuits that require two
pressure compensated flow controls.Integral lever allows on/unload pumpcontrol. This valve is designed forspeed control of two actuators whichmust have individual flow settings.The valve maintains constant regulatedflow to two actuators even with changesin load pressure. The »L« port sensesthe load pressure on both actuators tosignal the pump to increase ordecrease the supply flow. With the leverin the unload position, no load issensed and the pump destrokes. In theunload condition a 4,6 bar check valvemay be required in either the »A« port,the »S« port or both ports to reduce thepotential of motor movement.
Materials• Body – High-strength aluminium
alloy.• Internal parts – Hardened steel.• Seals – Viton A standard.
Regulated flow versushand knob detent positions
2FFLC12 - D 6 - 10/30 SV
Base Part No. SealsSV =Viton A
Regulated FlowRanges S (Spinner)
5 = 0-19 l/min7 = 0-26,5 l/min
10 = 0-38 l/min
Regulated FlowRanges A (Auger)15 = 0- 57 l/min30 = 0-115 l/min
Port Size6 = 3/4" NPTF = Inlet and Auger (P & A)
1/2" NPTF = Spinner (A)1/4" NPTF = Tank Load Sense (T & L)
Adjust. MeansD= Detented
Hand Knob
How to order
HK.66.B1.02 Danfoss Fluid Power 10/93
Fluid Power
8
Performance curve
Cartridge and Parts in Body 2FFL12
Dual Flow Regulator, Adjustable and Pressure Compensated,with Manual On/Unload Control and Relief
Max inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar
P
A
T
S
A
T
S
P
Typical circuit
121,2 ∅ 7,11L10 Reliefcartridge
101,6
≈ 132
42,9
16,0
63,5
88,9
95,880,3
≈ 106
63,5
Specifications• To 140 bar.• Inlet flow to 150 l/min.• Regulated flow to 115 l/min.• Weight: 3,08 kg.
Features• Honed and matched hardened steel
working parts for long life.• Relief protection on main line.• Rugged, dirt tolerant and reliable.• Adjustable and detented hand knob
with min. & max. stops. 11 positive,easy to adjust positions.
• Fully pressure compensated.• Gasket mounted models available.• On-unload lever control with detented
stops.• 100% performance tested.
Use and OperationFor use with fixed displacement pumpsin circuits that require two pressurecompensated flow controls, manualon-unload and pump relief. Ideal forspeed control of two actuators whichmust have individual flow settings.
Typical machinery applications includeagricultural equipment, salt and cinderspreaders and paving machinery.The valve maintains constant regulatedflow to two actuators even with changesin load pressure or input flow. Thepressure compensated regulatingsection bypasses excess pump flow totank. The pump operates at the highestload pressure plus control sectionpressure drop. The tank or bypass portmust be referenced directly to tank andnot to a working line. The direct actingrelief valve senses system pressureand protects the pump from shock oroverload pressure surges. The built-inlever operated two-way valve unloadssystem flow to tank. In the unloadcondition a 4,6 bar check valve may berequired in either the »A« port, the »S«port or both ports to reduce thepotential of motor movement. Thisallowson-unload control of both regulatedflows without changing either flowsetting.
How to order
Materials• Body – High-strength aluminium alloy.• Internal parts – Hardened steel.• Cartridge – Hardened steel.• Seals – Viton A standard.
Regulated flow versushand knob detent positions
Adjust. MeansD = Detented
Hand Knob
Port Size6 =3/4" NPTF
For Gasket Mtg.Consult Factory
Base Part No.
2FFL12 - D 6 - 10/30 SV
Regulated FlowRanges S (Spinner)
5 = 0-19 l/min7 = 0-26,5 l/min
10 = 0-38 l/min
Regulated FlowRanges A (Auger)15 = 0- 57 l/min30 = 0-115 l/min
SealsSV =Viton A
5,832,3
5,8
Fluid Power
HK.66.B1.02 Danfoss Fluid Power 10/93 9
Performance curve
TP
A
S
Cartridge and Parts in Body 2FFLW86
Dual Flow Regulator, Adjustable and Pressure Compensated,with Solenoid On/Unload Control and Relief
Max inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar
Typical spreader circuit
A
T
S
P
127,0
88,9
63,5
15,8
42,9
38,1
∅ 7,1
80,3
108,0
≈ 138
11,9
5,8 115,1
90,0
T
P
S A
≈ 240 63,5
≈ 105
1L10 Cartridge
Specifications• To 140 bar.• Inlet flows to 150 l/min.• Regulated flow to 115 l/min.• Weight: 3,08 kg.
Features• Honed and matched hardened steel
working parts for long life.• Relief protection on main line.• Adjustable and detented hand knob
with min. & max. stops. 11 positive,easy to adjust positions.
• Solenoid operated on/unload.• Fully pressure compensated.• 100% performance tested.
Use and OperationFor use with fixed displacement pumpsin circuits that require two pressurecompensated flow controls, solenoidvalve for on-unload and pump relief.Ideal for speed control of two actuatorswhich must have individual flowsettings. Typical machinery applications
include agricultural equipment, saltand cinder spreaders and pavingmachinery.The valve maintains constant regulatedflow to two actuators even with changesin load pressure or input flow. Thepressure compensated regulatingsection bypasses excess pump flow totank. The pump operates at the highestload pressure plus control sectionpressure drop. The tank or bypass portmust be referenced directly to tank andnot to a working line. The direct actingrelief valve senses system pressureand protects the pump from shock oroverload pressure surges. The built-insolenoid operated two-way valveunloads system flow to tank. In theunload condition a 4,6 bar check valvemay be required in either the »A« port,the »S« port or both ports to reduce thepotential of motor movement.Thisallows on-unload control of bothregulated flows without changing eitherflow setting.
Materials• Body – High-strength aluminium alloy.• Internal parts – Hardened steel.• Seals – Viton A standard.
How to order
Adjust. MeansD = Detented
Hand Knob
Base Part No. Port Size6 = 3/4" NPTF
Inlet, Tank andAuger (P, T & A);1/2" NPTFSpinner (S)
2FFLW86 - D 6 - 10/30 SV
Regulated FlowRanges S (Spinner)5 = 0-19 l/min7 = 0-26,5 l/min10 = 0-38 l/min
Regulated FlowRanges A (Auger)15 = 0- 57 l/min30 = 0-115 l/min
SealsSV =Viton A
Regulated flow versushand knob detent positions
HK.66.B1.02 Danfoss Fluid Power 10/93
Fluid Power
10
Performance curve
Cartridge and Parts in Body 2FFCW2
Dual Flow Regulator Pressure Compensated and Adjustable with Relief,Solenoid On/Unload and Load Sense
Max Inlet flow 150 I/min. Max reg. flow 115 I/min and 140 bar
1
2 3
9
60
11
4
5
10 8
7
1
2 3
9
60
11
4
5
10 8
7
Spinner
Auger
119,17,9
82,6
38,6
139,7108,0
38,1
9,4
12,7
25,463,5
84,1
103,1
63,5
127,0
111,0
23,6
≈ 197
≈ 102Detent adjust∅ 7,1
Thru 2-places
7W30-2-B12SVsolenoid cartridge
normally closed
Detentadjust
Specifications• Inlet to 150 l/min.• Regulated to 115 l/min.• Maximum inlet pressure: 140 bar.• Weight: 3,08 kg.
Features• Honed and hardened steel working
parts for long life.• Rugged, dirt tolerant and reliable.• Adjustable and detented with min.
& max. stops.• Pressure compensated.• IL10 differential area relief.• On-unload solenoid valve selector
(7W20).• 100% performance tested.
Use and OperationFor use with variable displacement,pressure compensated pumps in loadsensing circuits that require two
pressure compensated flow (speed)controls. Electric solenoid allows on-unload pump control. This circuit isdesigned for speed control of twoactuators which must have individualflow settings.This valve maintains constant regulatedflow to two actuators even with changesin load pressure. The L port senses theload pressure on both actuators tosignal the pump to increase or reducethe supply flow. With the solenoid in theunload position, no load is sensed andthe pump destrokes. In the unloadcondition a 4,6 bar check valve may berequired in either the »A« port, the »S«port or both ports to reduce thepotential of motor movement.
Materials• Body – High-strength aluminium
alloy.• Internal parts – Hardened steel.
How to order
2FFCW12 - D 6 - 10/30 SV
Regulated FlowRanges S (Spinner)
5 = 0-19 l/min7 = 0-26,5 l/min
10 = 0-38 l/min
Regulated FlowRanges A (Auger)15 = 0- 57 l/min30 = 0-115 l/min
Base Part No. Adjust. MeansD = Detented
Hand Knob
Port Size6 = 3/4" NPTF = Inlet and Auger (P & A)
1/2" NPTF = Spinner (A) 1/4" NPTF = Tank Load Sense (T & L)
SealsSV =Viton A
P
T
A
L
S
≈ 162
• Cartridge – Hardened steel.• Seals – Viton A standard.
Typical flow characteristics v.s. hand knobdetent positions for 5/15 randes
Fluid Power
HK.66.B1.02 Danfoss Fluid Power 10/93 11
CatalogueProducts
Ordering No.
Spreader Valves HK.66.B -.02
600 Series Valves HK.66.C -.02
400 Series Valves HK.66.D -.02
Relief Valves HK.66.F -.02
Sequence Valves HK.66.G-.02
Pressure Reducing Valves HK.66.H -.02
Motion Control Valves HK.66.I -.02
Unloading Valves and Pressure Intensifying Valves HK.66.J -.02
Needles and Restrictor Valves HK.66.K -.02
Flow Regulator Valves and Flow Divider Valves HK.66.L -.02
Pilot operated Check Valves HK.66.M-.02
Directional Control/Logic Valves HK.66.N -.02
Solenoid Directional Control Valves HK.66.O-.02
Fluid Controls Products
Product and catalogue survey
Fluid Power
HK.66.B1.02 © Danfoss Fluid Power 10/93
World Class Leadership in TechnologyDanfoss Fluid Power, a division of Danfoss, Inc., offers one of the world’slargest selections of quality fluid power components. An exceptional overalloffering of Danfoss, Dukes, Fluid Controls and Webster components allowsyou to choose the right products to meet your application. All of our units aremanufactured and tested to exacting engineering and quality control stan-dards to provide reliable long lasting performance.
Danfoss ProductsDanfoss products are known throughout the world for their quality, reliabilityand flexibility. From hydraulic motors, pumps, actuators and hydrostatic steer-ing components, to proportional hydraulics and electronics, Danfoss compo-nents redefine the leading edge.
Dukes ProductsThe Dukes name is recognized as the premier U.S. manufacturer of mobiledirectional control valves for applications to 115 l/min. Your specific needscan be addressed with mono-block or stack valves, or if required, a customdesigned valve.
Fluid Controls ProductsBeginning with the development of a compact, pilot-operated hydraulic reliefvalve over 40 years ago, Fluid Controls has remained a pioneer in hydraulicproduct miniaturization. Along with the wide variety of cartridge valves cur-rently available, Fluid Controls also features parts-in-body valves, andhydraulic integrated circuits to meet all of your requirements.
Webster ProductsSince 1945, Webster has been at the forefront in the development ofhydraulic gear pumps and cost effective multi-circuit components. Offering awide range of gear pumps and motors, Webster products can be found in amultitude of applications. The AC and DC power unit lines offer dependable,self-contained sources of hydraulic power. Flow dividers and rotary shearvalves further enhance the Webster line and expand the choices availablefrom Danfoss Fluid Power.
Danfoss A/S (SW-C) DTP 10.93 AO