Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09 Page 1 of 56 2-Dec-09 SUMMARY Sr. No. Description 1 Civil Works #REF! 2 Plumbing Works 7 67 44 481 3 Electrical Works 16 49 02 951 4 IBMS Works 6 32 16 724 5 Fire Fighting Works 67 15 674 Total Amount for Section A #REF! Labour Welfare Cess @ 1% #REF! Total Amount for Section A inc Labour C #REF! Section B: Provisional Items 6 Doors and Windows 7 56 80 940 7 HVAC Works 6 41 77 500 8 False Ceiling Works 68 53 125 9 Fixed Furniture & Carpentry Works 5 00 00 000 10 Elevators 1 08 00 000 11 Signage 48 00 000 12 Solid Waste Management System 25 00 000 13 Electrical works for Sports Fields Developm 1 44 26 760 14 Swimming pool filtration system 96 25 000 Total Amount for Section B 23 88 63 325 Total Amount for Section A + B #REF! Service Tax @ 4.12 % #REF! Grand Total for the Works: #REF! Signature of Authorised Signatory Stamp of the Bidder Civil, Plumbing, Electrical, Fire Fighting, Auxiliary and Site Development, Infrastructure & allied works for Aga Khan Academy, Hyderabad. Total Amount (Indian Rupees) Section A Amount in Words: Indian Rupees One Billion Six Hundred Fifty Million Fifty Seven Thousand One Hundred and Sixty Five Only

Upload: ptn999

Post on 26-Nov-2014

214 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: SPCL Offer 9(New)_03.12.09

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09 Page 1 of 53

2-Dec-09

SUMMARY

Sr. No. Description Total Amount (Indian Rupees)

Section A

1 Civil Works #REF!

2 Plumbing Works 7 67 44 481

3 Electrical Works 16 49 02 951

4 IBMS Works 6 32 16 724

5 Fire Fighting Works 67 15 674

Total Amount for Section A #REF!

Labour Welfare Cess @ 1% #REF!

Total Amount for Section A inc Labour Cess #REF!

Section B: Provisional Items

6 Doors and Windows 7 56 80 940

7 HVAC Works 6 41 77 500

8 False Ceiling Works 68 53 125 9 Fixed Furniture & Carpentry Works 5 00 00 000

10 Elevators 1 08 00 000

11 Signage 48 00 000

12 Solid Waste Management System 25 00 000

13 Electrical works for Sports Fields Development 1 44 26 760

14 Swimming pool filtration system 96 25 000

Total Amount for Section B 23 88 63 325

Total Amount for Section A + B #REF!

Service Tax @ 4.12 % #REF!

Grand Total for the Works: #REF!

Signature of Authorised Signatory Stamp of the Bidder

Civil, Plumbing, Electrical, Fire Fighting, Auxiliary and Site Development, Infrastructure & allied works for Aga Khan Academy, Hyderabad.

Amount in Words: Indian Rupees One Billion Six Hundred Fifty Million Fifty Seven Thousand One Hundred and Sixty Five Only

Page 2: SPCL Offer 9(New)_03.12.09

Tender DocumentsAga Khan Academy, Hyderabad

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 2 of 53

SUMMARY FOR CIVIL WORKS

Sr. No. Description Total Amount (Indian Rupees)

1 Section 01 - Earth Work 83,323,264

2 Section 02 - Concrete Work 431,299,519

3 Section 03 - Form Work 71,035,613

4 Section 04 - Masonry Work 50,690,214

5 Section 07 - Plastering Work 24,713,357

6 Section 08 - Waterproofing Work 50,002,016

7 Section 09 - Flooring Work 237,142,265

8 Section 10 - Structural Steel Work 19,424,554

9 Section 11 - Painting Work 33,373,350

10 Section 15 - General Development Work #REF!

Total Amount: #REF!

Amount in Words:

Signature of Authorised Signatory Stamp of the Bidder

Page 3: SPCL Offer 9(New)_03.12.09

Page 3 of 53

Sr. N0. Item description Unit Quantity Rate Amount

SECTION 1 - EARTH WORK

1.01

a) Depth upto 1.5m Cum 63,258 156 9,868,248

Rates in Words:

b) Depth 1.5m to 3m Cum 7,313 163 1,192,019

Rates in Words:

c) Depth 3m to 5m Cum 614 180 110,520

Rates in Words:

d) Depth 5m to 7m Cum 60 194 11,640

Rates in Words:

1.02

1.02.2 Hard Rock (Requiring Blasting)

a) Depth upto 1.5m Cum 2,558 568 1,452,944

Rates in Words:

b) Depth 1.5m to 3m Cum 25 625 15,625

Rates in Words:

c) Depth 3m to 5m Cum 25 688 17,200

Rates in Words:

d) Depth 5m to 7m Cum 25 756 18,900

Rates in Words:

1.03.b

1.03.b.1 All Kinds of Soil

a) Depth upto 1.5m Cum 42,163 95 4,005,485

Rates in Words:

b) Depth 1.5m to 3m Cum 24,676 99 2,442,924

Rates in Words:

c) Depth 3m to 5m Cum 4,771 109 520,039

Rates in Words:

d) Depth 5m to 7m Cum 800 120 96,000

Rates in Words: 1.03.b.2 Hard Rock (Requiring Blasting)

a) Depth upto 1.5m Cum 27,029 332 8,973,628

Rates in Words:

b) Depth 1.5m to 3m Cum 15,951 348 5,550,948

Rates in Words:

c) Depth 3m to 5m Cum 2,681 383 1,026,823

Rates in Words:

d) Depth 5m to 7m Cum 100 421 42,100

Rates in Words:

1.14 Cum 76,277 95 7,246,315

Rates in Words:

1.15 Cum 55,837 307 17,141,959

Rates in Words:

1.16 Cum 3,987 1,180 4,704,660

Rates in Words:

1.18.a

1.18.a.1 150mm compacted thickness using 100 to 150mm cut size stones Cum 2,432 1,110 2,699,520

Rates in Words: 1.18.a.2 230mm compacted thickness using 150 to 230mm cut size stones Cum 12,205 1,066 13,010,530

Rates in Words:

1.19

1.19.1 Within the plot area as directed by Engineer in-charge. Cum 3,071 64 196,544

Rates in Words: 1.19.2 Outside the plot area at no-objection place Cum 500 195 97,500

Rates in Words:

1.20 Sqm 30,347 39 1,183,533

Rates in Words:

1.22 Sqm 100,000 14 1,400,000

Rates in Words:

1.25

1.25.1 Beyond 30 cm girth upto and including 60 cm girth. No 175 517 90,475

Rates in Words: 1.25.2 Beyond 60 cm girth upto and including 120 cm girth. No 125 1,035 129,375

Rates in Words: 1.25.3 Beyond 120 cm girth upto and including 240 cm girth. No 5 7,781 38,905

Rates in Words: 1.25.4 Above 240 cm girth No 5 7,781 38,905

Rates in Words:

Sum Carried over to Summary page 83,323,264

SECTION 2 - CONCRETE WORK

2.01

2.01.3 Cum 100 3,364 336,400

Rates in Words: 2.01.4 Cum 16,234 3,096 50,260,464

Rates in Words: 2.01.5 Cum 50 2,858 142,900

Rates in Words:

2.06

2.06.1 Cum 1,509 3,100 4,677,900

Rates in Words:

REINFORCED CEMENT CONCRETE

2.09.b Cum 612 6,975 4,268,700

Rates in Words:

Earth work in excavation by mechanical means / manual means in foundation trenches, drains, manholes and soak wells etc. including necessary shoring & strutting, dewatering, getting out the excavated soil, sorting and stacking of useful material, dressing of the sides, ramming of bottom , backfilling into trenches and disposal of surplus excavated earth at non objectionable place within the site as directed by engineer-in-charge All kinds of soil.

Earth work in excavation by mechanical means / manual means in foundation trenches, drains, manholes and soak wells etc. including necessary shoring & strutting, dewatering, getting out the excavated soil, sorting and stacking of useful material, dressing of the sides, ramming of bottom , backfilling into trenches and disposal of surplus excavated earth at non objectionable place within the site as directed by engineer-in-charge. For all civil, electrical and plumbing works.

Earth work in excavation for mass areas, basements, water tanks, septic tanks, swimming pool etc. by mechanical means / manual means including necessary shoring & strutting, dewatering, getting out the excavated soil, sorting and stacking of useful material, dressing of the sides, ramming of bottom and disposal of surplus excavated earth at non objectionable place within the site for all lifts as directed by engineer-in-charge

Filling with available selected approved quality excavated earth (excluding rock and black cotton soil) brought from anywhere within the site in trenches, plinth, sides of foundations etc. in layers not exceeding 15 cms in depth including watering, ramming, consolidating each deposited layer for all leads and lifts.

Supplying and Filling in foundation and plinth with murrum or selected soil brought from outside in trenches, plinth, sides of foundation etc. in layers not exceeding 15 cm in depth, including watering, ramming, consolidating each deposited layer for all leads and lifts.

Filling in plinth with good quality river sand under floors including watering, ramming, consolidating and dressing complete.

Providing and laying rubble soling in plinth and for plinth protection, compacted thickness specified as following, using specified size of hard stones including filling, covering and leveling the surface with a layer of murrum after filling the voids with smaller size black trap stones 20-40mm, 40-63mm, 63-90, 90-150mm size of stone/metals or stone chips, including watering, ramming well and consolidating each layer by static roller/ vibratory roller or as directed by Engineer-in charge

Disposing of the surplus excavated earth and/or debris etc. including loading at site, transporting by mechanical or manual means & disposal, unloading, spreading and dressing and compacting etc. complete as directed.

Carrying out pre construction anti-termite treatment for all types of structure with / without basement with RCC foundation/RCC wall or with load bearing walled foundation. The chemical used shall be like chloropyriphos , Biflex TC, lindane etc. as per latest IS code no 6313 (Part II) . Plinth area in plan at GF shall only be measured and paid. A guarantee bond of 10 years shall be furnished. Rate shall be inclusive of material required for Anti Termite Treatment and labour for applying..

Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and diposal of rubbish (unwanted material) anywhere outside the site at non objectionable place. (Item shall be operated after prior approval from the client.) Site shall be selected by contractor.All kinds of Soil.

Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of the trunks and branches removing the roots and stacking of serviceable material shall be at non objectionable place within the site and disposal of unserviceable material anywhere outside the plot area at non objectionable place for all leads and lifts.Site shall be selected by contracor.

Providing and laying in position Plain cement concrete (PCC) of specified grade including finishing, curing, formwork (if required) etc. complete as directed by the engineer-in-charge - For All work upto Plinth level, Roads, Pavements, Plinth Protection, Kerbing etc.

1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)

1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

1:5:10 (1 Cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)

Providing and laying BBCC (Brick Bat cement concrete) of specified grade including finishing, curing, form work (if required) etc. complete as directed by enginner in charge. In foundations and Plinth.

1:3:6 (1 Cement : 3 Coarse Sand : 6 graded brickbats 40 mm maximum nominal size)

Providing, hoisting (By Mechnical means), fixing exposed finish precast cement concrete work in M25 grade with minimum cement content 360 Kg per cum for elements like lintels, beams, columns, slabs, window sills, shelves, moulding, cornices, trench covers etc including the cost of exposed centering, shuttering, rendering, erecting and keeping in position with cement mortar 1:3 (1 cement : 3 coarse sand)and necessary scaffolding at all floors, at any height and any level in any position etc. complete as directed by engineer-in-charge..

Page 4: SPCL Offer 9(New)_03.12.09

Page 4 of 53

Sr. N0. Item description Unit Quantity Rate Amount

2.11.a

2.11.a.1 70 mm thick (reinforced as per drawing) Sqm 2,052 888 1,822,176

Rates in Words:

2.12 Cum 11,718 4,213 49,367,934

Rates in Words: 2.12.1 Excluding the cost of centering, shuttering and reinforcement

Rates in Words:

2.13 Cum 8,512 4,430 37,708,160

Rates in Words: 2.13.1 Excluding the cost of centering, shuttering and reinforcement

Rates in Words:

2.14 Cum 100 4,679 467,900

Rates in Words: 2.14.a1 Excluding the cost of centering, shuttering and reinforcement

Rates in Words:

2.15b

Rates in Words: 2.15b1 Excluding the cost of centering, shuttering and reinforcement Cum 0 4,990

Rates in Words:

2.16

Note:

(i)

(ii)Rate to include the transportation with all leads from RMC plant to the place of work and pumping of concrete to any height and the rate shall be for all leads

(iii)

(iv)It is the responsibility of contractor ensures proper co-ordination for the timely supply of concrete and approved quality product

(v)

(vi) Contractor has to ensure proper strong shuttering / centering to receive the concrete at all heights.

(vii)

2.16.2 Cum 9,793 3,977 38,946,761

Rates in Words: 2.16.3 Cum 7,780 4,175 32,481,500

Rates in Words: 2.16.4 Cum 100 4,372 437,200

Rates in Words:

2.17.a

2.17.a3 MT 4,305 48,069 206,937,045

Rates in Words:

2.19

2.19.1 In RCC elements a Rmt 50 1,919 95,950

Rates in Words: b Rmt 1 2,029 2,029

Rates in Words: c Rmt 1 2,160 2,160

Rates in Words: d Rmt 75 2,643 198,225

Rates in Words: e Rmt 25 2,885 72,125

Rates in Words: f Rmt 10 3,126 31,260

Rates in Words: 2.19.2 In Brick Masonry

a Rmt 1 1,436 1,436

Rates in Words: b Rmt 1 1,556 1,556

Rates in Words:

Providing and fixing precast fair finished exposed cement concrete Jali as per architectural design of M20 grade including centering and shuttering, cleaning, finishing and fixing in cement mortar 1:3 (1 cement: 3 fine sand) excluding plastering of the jambs, sills and soffits and cost of reinforcement as directed by engineer-in-charge

Providing and laying in position machine batched, machine mixed and machine vibrated design mix fair finish / smooth finish cement concrete of M20 grade with minimum cement content 325 Kg per cum of concrete for reinforced cement concrete work for foundations, footings, RCC wall, slabs, beams, columns, staircase, vertical and horizontal fins, doms, shells and vaults of any shape, all places, all heights including laying of concrete to site, finishing and curing etc. and including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, to improve workability without impairing strength and durability as per direction of Engineer-in-charge. Rate shall be inclusive of providing grooves, drip moulds, ghisis, pockets, cutouts etc. and labour for insert sleeves if any wherever required while casting. Rate also to include lift charges and scaffolding for all heights / depths from FFL / GL.

Providing and laying in position machine batched, machine mixed and machine vibrated design mix fair finish / smooth finish cement concrete of M25 grade with minimum cement content 360 Kg per cum of concrete for reinforced cement concrete work for foundations, footings, columns, slabs, beams, pillars, staircase, vertical and horizontal fins, doms, shells and vaults of any shape including pumping laying of concrete to site, finishing and curing etc.and including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Rate shall be inclusive of providing grooves, drip moulds, ghisis, pockets, cutouts etc. and labour for insert sleeves if any wherever required while casting. Rate also to include lift charges and scaffolding for all heights / depths from FFL / GL

Providing and laying in position machine batched, machine mixed and machine vibrated design mix fair finish / smooth finish cement concrete of M30 grade with minimum cement content 400 Kg per cum of concrete for reinforced cement concrete work for foundations, footings, columns, slabs, beams, pillars, staircase, vertical and horizontal fins, doms, shells and vaults of any shape including pumping laying of concrete to site, finishing and curing etc.and including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Rate shall be inclusive of providing grooves, drip moulds, ghisis, pockets, cutouts etc. and labour for insert sleeves if any wherever required while casting. Rate also to include lift charges and scaffolding for all heights / depths from FFL / GL.

Providing and laying in position machine batched, machine mixed and machine vibrated design mix fair finish / smooth finish cement concrete of M40 grade with minimum cement content 450 Kg per cum of concrete for reinforced cement concrete work for foundations, footings, columns, slabs, beams, pillars, staircase, vertical and horizontal fins, doms, shells and vaults of any shape including pumping laying of concrete to site, finishing and curing etc.and including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Rate shall be inclusive of providing grooves, drip moulds, ghisis, pockets, cutouts etc. and labour for insert sleeves if any wherever required while casting. Rate also to include lift charges and scaffolding for all heights / depths from FFL / GL.

Providing and laying Ready Mixed Concrete as per mix design of specified grade in fully automatic batching plant as per the design mix standards at RMC manufacture’s site and transported to the place of work in transit mixer for any lead having continuous agitated mixture for reinforced cement concrete work.

The concrete is made using graded black trap stone aggregates of maximum 20mm nominal (down graded) size obtained from approved quarry including fine aggregates conforming to latest IS 383 and cement all as per the design mix proportions conforming to IS 10262 with minimum cement content for durability including supplying and providing concrete cover etc., which shall be followed as per latest IS 456 including pumping from transit mixer to all heights, placing, spreading, vibrating, compaction, finishing to required levels, curing etc., complete all as per specifications but excluding cost of formwork and steel reinforcement. Rate to include charges for providing and mixing additives or admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability, and labour for keeping embedment, insert sleeves) if any wherever required while casting. Rate also to include lift charges and scaffolding for all heights / depths from FFL / GL.Contractor shall get prior approval of the mix design before placing the order.

Ready Mixed Concrete should be from reputed manufacturers like ACC, L&T, Ready Mix, Birla RMC etc., and contractors have to obtain prior approval of EIC with respect to supplier of RMC.

Cement concrete delivered at site should be workable and should satisfy all the required standard tests like cube test and slump test etc or item description as specified in code of practice. Samples taken at site only will be deciding factor.

Contractor has to make arrangement for proper approach road (for which nothing extra shall be paid for) to enable the vehicle carrying concrete to move freely without any extra cost to the department before ordering the concrete. However existing approach road may be made use of for this purpose

The design mix of RMC for the manufacturer / supplier of RMC has to be obtained well in time and approval of Engineer in Charge to be obtained prior to use. The design mix should be based on latest IS 456. This approval has to be obtained whenever the design mix is changed. The RMC should be supplied confirming to the approved design mix which shall be continously checked during the progress of work. All the quality checks as per IS stipulations should be scruplously followed during the concreting. The work shall be carried out at all heights.

M20 Grade with (minimum cement 260 Kg + Flyash in reuiqred proportion) per cum

M25 Grade with (minimum cement 288 Kg + Flyash in required proportion) per cum

M30 Grade with (minimum cement 320 Kg + Flyash in required proportion) per cum

Supplying, fabricating and placing in position TMT reinforcement bars FE 415 confirming to IS-1786 reinforcement for RCC structure / items as per design including transporting steel to the work site, handling wastage, decoiling, cutting, bending, cranking, fabricating to required shape, placing in position, binding with 18 guage (1.22 mm) MS wires, welding if necessary by using approved welding rods etc. for all levels etc. complete as directed by the engineer-in-charge. The quoted rate should be inclusive the cost of binding wire and the same will not be measured and paid seprately. (rolling margin's and wastage shall not be paid.) Measurement will be made on the length basis and converted into weight by using standard co-efficient). The reinforcement shall be

TMT bars- Fe-415, yield stress not less than 415 N/mm2

Charges for making holes in walls, slabs, beams upto 350 mm depth or any other RCC member by core cutting machine of HILTI or equivalent including disposing the debris. Measurement will be taken for the depth of holes in running meter for specified diameter. For disposal of the debris specification of relevant items shall be followed. For executing the item prior approval of the structural consultant is required.

Holes of 52 mm clear diameter

Holes of 67mm clear diameter

Holes of 77mm clear diameter

Holes of 102mm clear diameter

Holes of 152 mm clear diameter

Holes of 202 mm clear diameter

Holes of 52 mm clear diameter

Holes of 67mm clear diameter

Page 5: SPCL Offer 9(New)_03.12.09

Page 5 of 53

Sr. N0. Item description Unit Quantity Rate Amountc Rmt 1 1,677 1,677

Rates in Words: d Rmt 1 1,919 1,919

Rates in Words: e Rmt 1 2,643 2,643

Rates in Words: f Rmt 1 2,885 2,885

Rates in Words: 2.19.3 In Stone Masonry

a Rmt 1 2,544 2,544

Rates in Words: b Rmt 1 2,655 2,655

Rates in Words: c Rmt 1 2,786 2,786

Rates in Words: d Rmt 1 3,269 3,269

Rates in Words: e Rmt 1 3,511 3,511

Rates in Words: f Rmt 0 3,752

Rates in Words: 2.20

2.20.1 200mm dia No 40 547 21,880

Rates in Words: 2.20.2 160mm dia No 70 335 23,450

Rates in Words: 2.20.3 110mm dia No 80 159 12,720

Rates in Words: 2.20.4 75mm dia No 140 78 10,920

Rates in Words: 2.21 Kg 5,000 5 25,000

Rates in Words:

2.22

a) 25 mm thk Sqm 1,455 879 1,278,945

Rates in Words:

2.23

a) size of expansion joint 25mm x 12mm Rmt 995 482 479,590

Rates in Words:

2.24 Rmt 884 1,316 1,163,344

Rates in Words:

Sum Carried over to Summary page 431,299,519

SECTION 3 - FORM WORK

3.01 Sqm 188,891 354 66,867,414

Rates in Words:

3.02.a Sqm 3,957 77 304,689

Rates in Words:

3.02.b Sqm 364 195 70,980

Rates in Words:

3.03.a Sqm 23,945 119 2,849,455

Rates in Words:

3.03.b Sqm 7,925 119 943,075

Rates in Words:

Sum Carried over to Summary page 71,035,613

SECTION 4 - MASONRY WORK

4.01

4.01.1 In foundations and Plinth (i) CM 1:4 (1 Cement : 4 coarse Sand) Cum 1,079 2,933 3,164,707

Rates in Words: 4.01.2 Super structure plinth for all levels

(iii) CM 1:6 (1 Cement : 6 coarse Sand) Cum 12,143 2,941 35,712,563

Rates in Words:

4.04.a

4.04.a.2 Without Reinforcement (A) 115 mm thick (ii) CM 1:4 (1 Cement : 4 coarse Sand) Sqm 5,346 384 2,052,864

Rates in Words:

4.09 Sqm 25 7,507 187,675

Rates in Words: 4.10

4.10.1 Wire Cut bricks Cum 25 2,260 56,500

Rates in Words: 4.10.2 Best quality hand moulded bricks Cum 25 1,624 40,600

Rates in Words:

4.11 Cum 806 2,372 1,911,832

Rates in Words:

Holes of 77mm clear diameter

Holes of 102mm clear diameter

Holes of 152 mm clear diameter

Holes of 202 mm clear diameter

Holes of 52 mm clear diameter

Holes of 67mm clear diameter

Holes of 77mm clear diameter

Holes of 102mm clear diameter

Holes of 152 mm clear diameter

Holes of 202 mm clear diameter

Providing in position UPVC sleeves of 6Kg/cm2 and length upto 500 mm for following diameters of

Providing additional cement in design mix of RCC to achieve desired exposed finish surface.

Providing and fixing in expansion joints, Capcell HD 100 Supreme or equivalent (Polyurethane foam filler) of the best quality, including in all shapes and all levels etc. complete as directed by engineer-in-charge..

Providing and filling the expansion joints, with polysulphide sealant with application of primer including scraping / removing the expansion filler materials from joints, cleaning, repaing of the edges with epoxy mortar of approved color and make, placing of backup material (polyethylene baker rod of Supreme), fixing of abro tapes on the edges to prevent the adjoining surface, etc. complete as directed by engineer-in-charge. The contractor should furnish a gurantee of 10 years as directed.

Providing and fixing in expansion joints, copper strip water stop of 1.25 mm thick & 125 mm wide with 'U' of 25 mm depth in middle with 3 mm dia copper rod 25 cm long, soldered on strip at an interval of 30 cm as specified in drawing, as per sample approved and as directed by Engineer-In-Charge

Form Work (Centering and shuttering) including strutting, propping, bracing etc. complete to give fair / smooth finish using best quality ordinary timber planking, shuttering plywood (plain or laminated) or steel plates with MS adjustable steel props, H frames with bracing, adjustable spans, etc. including removal of forms for foundations, footings, bases of columns, walls, slabs beams, sills, lintels, coping, staircases, arches, chajjas etc. in all shapes at all levels etc. complete as directed by engineer-in-charge. The Height of propping and centering from supporting floor to ceiling should not exceed 4.5 meter.

Extra over item no. 3.01 (Form Work) for providing and erecting false staging with MS props or MS H frames for each additional height of propping and centering where the height of propping and centering exceeds 4.5 m between supporting floor to ceiling, including temporary masonry work, stone pillars for supporting as required for steel props, H Frames etc. including cost of deshuttering and centering at all levels.(height more than 4.5 m. and upto 9.0 m) No staging shall be measured for vertical walls & beam sides and only plan area is to be measured.

Extra over item no. 3.01 (Form Work) for providing and erecting false staging with MS props or MS H frames for each additional height of propping and centering where the height of propping and centering exceeds 9.0 m. between supporting floor to ceiling, including temporary masonry work, stone pillars for supporting as required for steel props, H Frames etc. including cost of deshuttering and centering at all levels. (height more than 9.0 m. and upto 18.0 m between supporting floor to ceiling). No staging shall be measured for vertical walls, columns & beam sides and only plan area is to be measured.

Extra over item no. 3.01 (formwork) for providing formwork for exposed concrete surfaces (vertical or horizontal surface) in desired pattern and size, using laminated shuttering plywood, for slabs, soffits, walls, columns, pillars, beams, lintels, beam hunching, vertical fins etc. including neat cleaning the exposed concrete surface, as directed by the engineer-in-charge. (Same kind of shuttering material should be only used for standard and residual sizes.)

Extra over item no. 3.01 (formwork) for providing formwork for exposed concrete surfaces ( vertical or horizontal surface) in desired pattern and size, using best quality steel shuttering plates, steel sheeting, for slabs, soffits, walls, columns, pillars, beams, lintels, beam hunching, vertical fins etc. including neat cleaning the exposed concrete surface, as directed by the engineer-in-charge. (Same kind of shuttering material should be only used for standard and residual sizes.)

Providing and laying brick work using common burnt clay conventional building bricks conforming to IS 1077-1992 having compressive strength not less than 50 Kg/cm2 in any shape and all depth including curing, scaffolding etc. complete as directed by engineer-in-charge.

Providing and laying half brick masonry with common burnt clay building bricks having compressive strength not less than 50 Kg/cm2 at all heights, levels, locations and shapes etc. including curing, scaffolding etc. complete as directed by the engineer-in-charge

Providing and fixing 190mm x 190 mm x 80 mm glass bricks of approved make and design with white CM 1:2 ( 1 white cement : 2 sand). Two numbers of 5 mm thick GI wires to be passed through PVC spacers in each joint horizontal as well as vertical by drilling holes in surrounding surface (brick or RCC) and filling the same with Hilti or equivalent chemical (rebarring). The PVC concealed spacer (with provision for passing the 2 no. GI wires in horizontal and vertical direction) shall be provided to maintain grooves/spaces for GI wire and white cement mortar at the junction of two glass bricks. The sample of the glass brick shall be got approved by Architect. The glass bricks shall be fixed with placing GI wires vertically as well as horizontally after passing through the spacer and having minimum lap length of + 200 mm as per the site conditions at all the places, heights and shapes, etc. complete, as per the details and drawing to the satisfaction of Engineer-in-charge. Joints along the periphery of glass bricks to be filled with approved make and color weather silicone sealant of DOW corning or equivalent.

Extra for providing exposed finish to brickwork at all heights, shapes in any position. The bricks used shall be

Providing and laying uncoursed rubble masonry, with hard stone, locally available granite stone approved by architect, in foundations and plinth, in CM 1:4 (1 cement : 4 coarse sand) including leveling, etc. complete, as directed by engineer in charge.

Page 6: SPCL Offer 9(New)_03.12.09

Page 6 of 53

Sr. N0. Item description Unit Quantity Rate Amount

4.13 Cum 2,837 2,406 6,825,822

Rates in Words:

4.14 Cum 277 2,663 737,651

Rates in Words:

Sum Carried over to Summary page 50,690,214

SECTION 7 - PLASTERING WORK

7.01.b Sqm 44,424 160 7,107,840

Rates in Words:

7.02.b Sqm 73,779 160 11,804,640

Rates in Words:

7.03.a Sqm 20,941 211 4,418,551

Rates in Words:

7.04.a Sqm 1,226 234 286,884

Rates in Words:

7.10 Sqm 12,947 76 983,972

Rates in Words: 7.11.a

7.11.a.1 Brick work Sqm 100 70 7,000

Rates in Words: 7.11.a.3 Coursed Rubble masonry Work Sqm 100 70 7,000

Rates in Words: 7.11.a.4 Uncoursed Rubble masonry Work Sqm 100 70 7,000

Rates in Words: 7.11.c

7.11.c.1 Brick work Sqm 100 83 8,300

Rates in Words: 7.11.c.3 Coursed Rubble masonry Work Sqm 990 83 82,170

Rates in Words:

Sum Carried over to Summary page 24,713,357

SECTION 8 - WATERPROOFING WORK

8.01.a Sqm 24,524 545 13,365,580

Rates in Words:

i)

ii)

iii)

iv)

v)

8.02.a Sqm 4,518 545 2,462,310

Rates in Words:

8.02.c Sqm 497 426 211,722

Rates in Words:

8.05.b Sqm 5,095 292 1,487,740

Rates in Words:

8.06 Sqm 4,651 284 1,320,884

Rates in Words:

8.12 Rmt 118 486 57,348

Rates in Words:

8.13 Sqm 24,524 1,268 31,096,432

Rates in Words:

Sum Carried over to Summary page 50,002,016

SECTION 9 - FLOORING WORK

9.02.a Sqm 1,050 844 886,200

Rates in Words:

Providing and laying uncoursed rubble masonry with hard stone, locally available granite stone approved by architect in superstructure above plinth and for all floors in CM 1:6 including curing, leveling etc. complete as directed by engineer in charge.

Providing and laying coursed rubble masonry with hard stone, locally available granite stone approved by architect in superstructure above plinth and for all floors in CM 1:6 including curing, leveling etc. complete as directed by engineer in charge.

Providing and laying average 10 mm thick single coat mala finish (finished smooth with steel trowel) plaster in CM 1:3 , on ceilings and stair soffits at all floors, all shapes and all heights with necessary scaffolding, curing, making grooves, forming pattas, hacking properly to RCC surface (144 nos. of hacks per sqft) etc. complete as directed by Engineer-in-charge. The plaster mortar shall be machine mixed.

Providing and laying average 15 mm thick single coat mala finish plaster in CM 1:4 (1 cement : 4 Coarse sand) with polypropylene fibers in recommended proportions on sides of brickwork/ blocks at all floors, all shapes and all heights with necessary scaffolding, curing, making grooves, forming pattas, hacking properly RCC surface etc. complete as directed by the Architect and Engineer-in-charge. The plaster mortar shall be machine mixed.

Providing & laying average 18 mm thick mala finish cement plaster in two coats at all heights, all shapes and all levels with 12 mm thick under coat in CM 1:4 (1 cement : 4 coarse sand) rough wired finish and 6 mm thick finishing coat in CM 1:3 (1 cement : 3 fine sand) mala finish (finished with steel trowel) including scaffolding, curing, making grooves, forming pattas and drip mould, hacking RCC surface etc. complete, as directed by Engineer-In-charge. The plaster mortar shall be machine mixed.

Providing and laying average 18-20 mm. thick Sand face cement plaster on walls upto any height above ground level and for all shapes consisting of average 12-15 mm. thick backing coat of CM 1:4 (1 cement: 4 coarse sand) with polypropelene fibersand average 6 mm. thick uniform grained textured finish coat using wooden Gutka, in CM 1:3 (1 cement: 3 sand), including scaffolding, forming grooves, drip moulds, pattas, hacking RCC surface, curing etc. complete as directed by engineer-in-charge. The plaster mortar shall be machine mixed.

Providing and fixing hexagonal chicken mesh of size 20 mm. x 20 mm. of 22 gauge at junction of concrete and brick work or between different materials, etc. as directed by engineer in charge.

Flush pointing on the following work with Cement Mortar 1:2 (1 Cement : 2 Fine Sand)

Recessed pointing on the following work with Cement Mortar 1:2 (1 Cement : 2 Fine Sand)

Providing and laying integral cement based brickbat coba water proofing treatment average 115mm thick and minimum thickness at khurra as 65 mm including preparation of surface as required for treatment on roofs, balconies, terraces etc. at all floors consisting of following operations and furnishing a guarantee bond of 10 years.

Cleaning and applying a cement slurry with mixed with water proofing compound as manufacture's specification as directed by engineer-in-charge over the slab including adjoining walls upto 300 mmheight including cleaning the surface before the treatment

Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.

After three days of proper curing applying a second coat of cement slurry admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge

Finishing the surface to make wired finish with average 12 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge

The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge. (Only plan area shall be measured, vata shall not be measured separately and paid for.)

Providing and laying integral cement based brickbat coba water proofing treatment average 75mm thick including preparation of surface as required for treatment on sunk slabs of toilets, depressed portions etc. at all floors consisting of following operations and furnishing a guarantee bond of 10 years.

Providing and laying crystalline water proofing treatment of ZYPEX or equivalent to vertical and horizontal surfaces of depressed portions of toilets, pantry and the like as per manufacture’s specification or as directed by the engineer-in-charge and furnishing a guarantee bond of 10 years. Only plan area shall be measured, vata shall not be measured separately and paid for.)

Providing 18 to 20 mm. thick Water proof cement plaster in double coat on sides of masonry / RCC wall at all heights, first coat of 12 to 15 mm thk under coat in cement mortar 1:3 (1 cement : 3 sand) and second coat of 5 to 6 mm thk with cement mortar 1:3 (1 cement : 3 sand) including providing and mixing water proofing compound such as Hydroshield powder & liquid of ConTech Chemicals, Fosroc, CICO or equivalent in recommended proportions in both coats as approved by the Architect and Engineer-in-charge and finishing the surface smooth finish with neat cement slurry at 2.75 Kg per sqm etc complete including furnishing a guarantee bond for 10 years, hacking to RCC surface. Cement slurry admixed with Hydroshield powder & liquid of ConTech Chemicals, Fosroc, CICO or equivalent in recommended proportions is to be applied before each coat and final finishing coat

Providing and laying average 60 mm thick water proof cement concrete flooring in 1:2:2 (1 Cement : 2 Sand : 2 Graded Aggregate 10mm nominal size) to RCC swimming pool floor, water tanks at all heights in line, level and gradient including mixing water proofing compound such as Hydroshield powder & liquid of ConTech Chemicals, Fosroc, CICO or equivalent in recommended proportions as approved by the Architect and Engineer-in-charge and leaving the surface rough wired finish to receive any type of flooring / smooth finish etc complete including furnishing a guarantee bond for 10 years. Rate shall be inclusive of curing, scaffolding etc. as directed

Providing and placing in position suitable size (width, thickness based on water head and pressure) PVC water stops conforming to IS : 12200 as approved by consultant for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete as directed by engineer in charge.

Providing and laying over deck insulation over terrace water proofing of 115 mm thick ex-foliated vermiculite of Porosil or equivalent for roof insulation in the ratio of 1 :6 (1 cement : 6 Ex foliated vermiculite (by volume)). Density of Ex foliated vermiculite shall be 212 kg/cum. The cement shall be mixed with the ex foliated vermiculate in dry stage & then minimum qty of water shall be added. After screeding the ready mixed material in specified thickness, curing shall be carried out at least for for 7 days by sprinkling of required quantity of water so that surface remains damp and not to be done by ponding or flooding. The work includes cleaning of the surface with wire brush thoroughly necessary scaffolding finishing the top surface as best workmanship like manner as per the manufacturers specifications and as directed by Engineer In charge.

Providing and laying ceramic tiles of required surface finish (Matt, Satin, Glossy, Non skid, Rustic) in floor with residue and skirting of approved make and shade as per design laid over 20 mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand) bedding on 40 mm wired finish screed 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size ), laid to proper slope and level. Finishing should be done with pointing the joints with white cement and matching pigment, including curing, cleaning with mild oxalic acid, protecting the flooring until handing over to the client etc. complete as directed by Engineer-in-charge. The rate should include the covering & protecting of flooring with plastic + POP, or as required, removing the same at the time of handing over after completion of the item until handing over to client.

Page 7: SPCL Offer 9(New)_03.12.09

Page 7 of 53

Sr. N0. Item description Unit Quantity Rate Amount

9.02.c Sqm 50 755 37,750

Rates in Words:

9.02.d Sqm 50 984 49,200

Rates in Words:

9.03.a Sqm 50 1,644 82,200

Rates in Words:

9.03.b Sqm 3,233 1,660 5,366,780

Rates in Words:

9.03.d Sqm 9,356 1,571 14,698,276

Rates in Words:

9.03.e Sqm 25 1,784 44,600

Rates in Words:

9.04.a

9.04.a.2 Sqm 200 247 49,400

Rates in Words:

9.04.b Kg 3,120 36 112,320

Rates in Words:

9.04.c Kg 1,000 492 492,000

Rates in Words:

9.09.a Sqm 27,746 455 12,624,430

Rates in Words:

9.09.b Sqm 4,410 555 2,447,550

Rates in Words:

9.10.a Sqm 37,715 1,152 43,447,680

9.10.b Sqm 100 1,287 128,700

Rates in Words:

Providing and laying in position ceramic wall tiles of required surface finish (Matt, Satin, Glossy, Non skid, Rustic) for dado, risers of steps etc. of approved make and shade as per design and drawing. Tile is to be fixed over 12 to 15 mm thick wired finish plaster in cement mortar 1:4 ( 1 cement : 4 coarse sand) with polypropylene fibers. Tile shall be fixed with 1:1 cement sand mortar of average 6 mm thickness behind the tiles including pointing in white cement mixed with pigment of matching shade etc. complete as approved by architect and directed by engineer-in-charge. Rate is inclusive of back coat of 12 to 15 mm thick plaster. The rate should include the covering & protecting of flooring with plastic + POP, or as required, removing the same at the time of handing over after completion of the item until handing over to client. In case of hollow sound upon tapping the tile after laying / fixing, the tile would have to be removed and replaced at contractors cost.

Providing and fixing ceramic tiles in dado of required surface finish (Matt, Satin, Glossy, Non skid, Rustic) with cement based polymer adhesive like BAL or equivalent with minimum 3 mm thickness or as manufacture’s specification. The material, workmanship, coverage area shall be carried out as per the supplier’s specifications and approved by architect and engineer-in-charge. In dado adhesive is to be applied over smooth finish mala plaster (1:4) instead of wired plaster. Rate is inclusive of mala finish plaster on the masonry wall. The rate should include the covering & protecting of flooring with plastic + POP, or as required, removing the same at the time of handing over after completion of the item until handing over to client.

Providing and laying vitrified tiles of approved make and shade as per design in floor with residue and skirting of desired colors and size of first quality over a minimum 20 mm. thick cement mortar 1:3 bedding on 40 mm wired finish screed and laid to proper slope and level. Finishing to be done with flush pointing in white cement and matching pigment including curing and cleaning with mild oxalic acid etc. complete as directed by Architects and Engineer-in-charge. Rate shall be inclusive of protection of flooring until the handling of the project by covering the joints with abrotaps, platic sheet and plaster of paris & removing the same at the time of handing over as directed by engineer in charge.

Providing and laying vitrified tiles of approved make and color as per design in floor with residue and skirting of desired colors and size of first quality, over a minimum 20 mm. thick cement mortar 1:3 bedding on 40 mm wired finish screed and laid to proper slope and level. Groove of (3mm x 5mm) is prepared with PVC spacer of approved make and filling in groove is to be done with cementitious grout of matching shade including curing and cleaning with mild oxalic acid etc. complete as directed by Architects and Engineer-in-charge. Rate shall be inclusive of filling in grooves with cementitious grout and protection of flooring until the handling of the project by covering the joints with abrotaps, plastic sheet and plaster of paris & removing the same at the time of handing over as directed by engineer in charge.

Providing and laying in position vitrified wall tiles of required surface finish (Matt, Satin, Glossy, Non skid, Rustic) for dado, risers of steps etc. of approved make and shade as per design and drawing. Tile is to be fixed over 12 to 15 mm thick wired finish plaster in cement mortar 1:4 (1 cement : 4 coarse sand) with polypropylene fibers in recommended proportions with keeping a groove of (3mm width X 5 mm depth). Tile shall be fixed with 1:1 cement sand mortar of average 6 mm thickness behind the tiles including filling the grooves with cementitious grout of matching shade etc. complete as approved by architect and directed by engineer-in-charge. Rate shall be inclusive of 12 to 15 mm thick wired finish plaster with polypropylene fibers in cement mortar 1:4 and filling in grooves with cementitious grout. The rate should include the covering & protecting of flooring with plastic + POP, or as required, after completion of the item until handing over to client & removing the same at the time of handing over to client. In case of hollow sound upon tapping the tile after laying / fixing, the tile would have to be removed and replaced at contractors cost.

Providing and fixing vitrified tiles in dado with cement based polymer adhesive like BAL or equivalent in with minimum 3 mm thickness or as manufacture’s specification. The material, workmanship, coverage area shall be carried out as per the supplier’s specifications and approved by architect and engineer-in-charge. In dado adhesive is to be applied over smooth finish mala plaster instead of wired plaster. Rate is inclusive of smooth finish mala plaster. The rate should include the covering & protecting of flooring with plastic + POP, or as required, after completion of the item until handing over to client and removing the same at the time of handing over to client.

Cement concrete flooring (IPS) 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate) laid in one layer finished with trowel finish using 1:1 cement sand mortar for filling the minor holes etc. or alternate panels using 5 mm thk glass strips finished with a trowel including curing etc. complete as per design or as directed by engineer-in-charge.

50 mm thick with 6 to 10 mm nominal size stone aggregate

Supplying and sprinkling nonmetallic floor hardener of Ironite or equivalent @ 4 Kg per sqm or as per supplier's specification over green concrete surface / IPS. Rate includes finishing surface with power floater as per design or as directed by engineer-in-charge.

Extra for providing and mixing Fibermesh 150 e3 ( Formerly Stealth e3 ) multi dimensional graded multifilament 100% virgin polypropylene fibers manufactured by M/s. PROPEX CONCRETE SYSTEMS, U.S.A. and represented by “M/s. NINA CONCRETE SYSTEMS PVT. LTD.@ 0.9 Kg per cum or as per manufacture’s specification of approved make while doing the cement concrete in cement concrete pavement / IPS as per supplier's specification and approved by architect and engineer-in-charge.

Providing & laying broken white china mosaic flooring for plain and curved surfaces, comprising of 20 to 25 mm. size broken pieces of ceramic/glazed tiles laid over cement mortar 1:6 bedding including applying cement slurry at the rate of 2.75 kg per sq.m. on plain or sloped surfaces. and filling joints with white cement. The flooring shall be tampered to bring the mortar up to the surface, including rounding of the junctions and extending them upto 15 cm. along the parapet wall. The rate shall include bands, if different colour is used, any pattern or design as per drawing and direction, curing, cleaning with water and oxalic acid, etc. complete. (Wall to wall measurement will be considered only including vata upto 150mm height). The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing and laying in position white china mosaic on dado comprising of 20 to 25 mm size broken pieces of ceramic / glazed tiles laid over 12 to 15 mm thick wired finish plaster in cement mortar 1:4 ( 1 cement : 4 coarse sand) with polypropelene fibers including applying a cement slurry at 2.75 Kg per sqm on plastered surface. China mosaic shall be fixed with 1:2 cement sand mortar of average 6 mm thickness including filling the joints with white cement. The dado shall be tampered to bring the mortar up to the surface. The rate shall be inclusive of bands, if different color is used, any pattern or design as per drawing and direction, curing, scaffolding, cleaning with water etc. complete as directed by the engineer in charge. Rate is inclusive of 12 to 15 mm thk wired finish plaster in cement mortar 1:4. The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing and laying average 25mm (20 to 30 mm) thick hand dressed / machine cut green polished kotah stone of approved quality, selected and sorted for uniform colour, in floor, otta and skirting etc. of required sizes upto 600 mm as per design in normal pattern (square or rectangular) and residue as per drawing, including 1:6 (1 cement : 6 sand) cement mortar bedding of average 35 to 50mm thickness, jointed with grey cement and colour pigment as specified. Polishing to be done with 2 coats of 60, 120 grades of emery, balckchapadi and gutka for special polish, after it polishing to be done with 220, 320, 400, 600 grades of emery till semimirror finish is achieved. Curing, daily moping with water & kerosene as directed for at least 15 days after final polishing etc. complete with marble stone to form bands (marble flooring and bands shall be paid under relevant item) upto the satisfaction of the Architect or Engineer-in-charge.(NO WAXING WILL BE PERMITTED.)The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing and laying average 25mm (20 to 30 mm) thick hand dressed / machine cut green polished kotah stone of approved quality, selected and sorted for uniform color, in floor, otta and skirting etc. of required sizes upto 600 mm as per design in diagonal pattern and residue as per drawing, including 1:6 (1 cement : 6 sand) cement mortar bedding of average 35 to 50mm thickness, jointed with grey cement and colour pigment as specified. Polishing to be done with 2 coats of 60, 120 grades of emery, balckchapadi and gutka for special polish, after it polishing to be done with 220, 320, 400, 600 grades of emery till semimirror finish is achieved. Curing, daily moping with water & kerosene as directed for at least 15 days after final polishing or upto the satisfaction of the Architect or Engineer-in-charge etc. complete. (NO WAXING WILL BE PERMITTED). The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Page 8: SPCL Offer 9(New)_03.12.09

Page 8 of 53

Sr. N0. Item description Unit Quantity Rate Amount

9.10.c Sqm 50 1,287 64,350

9.10.e Sqm 1,055 1,093 1,153,115

Rates in Words:

9.12.a

9.12.a.1 Rough Kota Stone Sqm 14,574 950 13,845,300

Rates in Words: 9.12.a.2 Rough Tandoor Stone Sqm 13,000 540 7,020,000

Rates in Words: 9.12.a.3 Rough Black Kadappa Stone Sqm 13,000 654 8,502,000

Rates in Words:

9.13.c Sqm 2,491 1,204 2,999,164

Rates in Words:

9.13.d Sqm 458 1,245 570,210

Rates in Words:

9.14 Sqm 50 1,261 63,050

Rates in Words:

9.15 Rmt 2,726 162 441,612

Rates in Words:

9.16 Sqm 1,000 115 115,000

Rates in Words:

9.17 Sqm 6,727 2,960 19,911,920

Rates in Words:

9.18 Sqm 100 115 11,500

Rates in Words:

9.21 Sqm 50 1,916 95,800

Rates in Words:

9.24.a Sqm 147 3,203 470,841

Rates in Words:

9.24.b Sqm 17 3,541 60,197

Rates in Words:

9.24.c Sqm 189 3,390 640,710

Rates in Words:

9.25.b Sqm 500 480 240,000

Rates in Words:

9.28 Sqm 12,376 622 7,697,872

Rates in Words:

Providing and laying average 25mm (20 to 30 mm) thick hand dressed / machine cut green polished kotah stone of approved quality selected and sorted for uniform colour, in floor, otta and skirting etc. of required sizes above 600 mm and upto 1000 mm as per design in normal pattern (square or rectangular) and residue as per drawing, including 1:6 (1 cement : 6 sand) cement mortar bedding of average 35 to 50mm thickness, jointed with grey cement and color pigment as specified. Polishing to be done with 2 coats of 60, 120 grades of emery, balckchapadi and gutka for special polish, after it polishing to be done with 220, 320, 400, 600 grades of emery till semimirror finish is achieved. Curing, daily moping with water & kerosene as directed for at least 15 days after final polishing or upto the satisfaction of the Architect or Engineer-in-charge etc. complete. (NO WAXING WILL BE PERMITTED). The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing and laying in position average 10 mm thick green kota stone of approved quality, selected and sorted for uniform color in skirting of required size as per design and drawing. Kota stone is to be fixed over 8 mm thk cement mortar (1:1) jointed with grey cement and color pigment. Polishing to be done with 2 coats of 60, 120 grades of emery, balckchapadi and gutka for special polish, after it polishing to be done with 220, 320, 400, 600 grades of emery till semimirror finish is achieved. Curing, daily moping with water & kerosene as directed for at least 15 days after final polishing or upto the satisfaction of the Architect or Engineer-in-charge etc. complete, (NO WAXING WILL BE PERMITTED). The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing & laying average 25 mm thick stone of following type of approved quality, selected and sorted for uniform color, in floor, otta, sill, skirting, tread, riser etc., in required sizes upto 60 cm. as per design and drawings (with grooves). Kota stone to be laid over cement mortar 1:6 bedding of average 35 to 40 mm thickness with joints, pointing and making grooves as specified, including curing and cleaning upto the satisfaction of the Architect & Engineer-in-charges etc. complete. (NO WAXING WILL BE PERMITTED) The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing & fixing average 25 mm thick single side prepolished (upto semimirror finish) green kotah of uniform size and color for platforms, staircases, sinks, shelves, morry etc. from 1.0 m. to 1.5 m long, including necessary machine-cut edges (uniform thickness) rounded edges, necessary cement mortar bedding in CM 1:3 of average 20 mm thickness. Cement joints and pointing as specified with polishing, curing, daily mopping with water and kerosene as directed for atleast 15 days or upto the satisfaction of the Architect & Engineer-in-charge etc. complete. The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing & fixing average 25 mm thick both side prepolished (upto semimirror finish) green kota of uniform size and color for shelves and vertical partitions etc. from 1.0 to 1.5m long, including necessary machine-cut edges (uniform thickness) rounded edges, necessary cement mortar bedding in CM 1:3 of average 20 mm thickness. Cement joints and pointing as specified with polishing, curing, daily mopping with water and kerosene as directed for atleast 15 days or upto the satisfaction of the Architect & Engineer-in-charge.

Providing & fixing green pre polished kota (upto semimirror finish) of average 50 mm. thick of uniform size and colour for sills, floor etc. in required sizes from 1.0 m. to 1.5 m. long, including necessary machine-cut edges (uniform thickness), rounded edges, necessary cement mortar bedding in CM 1:3 of required thickness, average 20 mm. Cement joints and pointing as specified with polishing , curing, daily mopping with water and kerosene as directed for atleast 15 days or upto the satisfaction of the Architect & Engineer-in-charge. The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing roughened strip 2.5 cm. wide to form antiskid surface on any flooring as per design, including forming straight deep curved gishi (groove), 6 mm. Wide & 4 mm deep on two sides of the roughened area, chiseling, polishing the edges, sides and bottom of gishis etc. complete as per sample approved and as directed by engineer in charge.

Extra for providing special mirror finish polish on kotah flooring over semi mirror polish with different grades of emery like 800, 1200, 5x and buffing with tin oxide. All work to be carried out with polishing machine.

Providing and laying average 18 mm thick marble stone flooring of approved quality (sample of marble stone shall be approved by architect) as per design in required sizes and shapes including bands in polished kotah stone flooring over 35 to 40 mm (average) thick bedding of cement mortar 1:3 (1 cement: 3 coarse sand) laid and jointed with white cement and matching pigment including rubbing, semi mirror polishing with different grades of Emery, curing etc. complete.Polishing to be done with 2 coats of 60, 120 grades of emery, balckchapadi and gutka for special polish, after it polishing to be done with 220, 320, 400, 600 grades of emery till semimirror finish is achieved. (Only finished marble work will be measured.) The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Extra for providing special mirror finish polish on marble flooring over semi mirror polish with different grades of emery like 800, 1200, 5x. All work to be carried out with polishing machine.

Providing & laying machine cut single polished “Agra Red” minimum 25 mm. thick slab upto 600 mm in flooring or as per design and drawing in in normal pattern straight or staggered joint with square or rectangular shaped stone (with grooves 10mm wide or without grooves) in cement mortar 1:6 bedding of average 35 to 50mm thickness, pointing with matching pigment and white cement in joints or filling the grooves with CM 1:2 and matching pigment, curing etc. complete. The rate shall also include for rubbing and polishing (without scratches and marks of emeries) with different grade of emery etc. complete. The work shall be carried out as per the approval of architect and engineer-in-charge.The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing & laying 18 to 20 mm thick mirror finished granite of approved shade and quality, selected and sorted for uniform color in floor, skirting as per design size upto 900 mm over average 40 mm thick cement mortar bedding in 1:3. (Only finished granite work shall be measured). The rate includes rounding, champhering and mirror polishing of edges. The work shall be carried out as per the approval of architect and engineer-in-charge. The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing & laying 18 to 20 mm thick flame finished granite of approved shade and quality, seleted and sorted for uniform color in floor, skirting as per design and in required sizes and shapes over 35 to 40 mm thick cement mortar bedding in 1:3. (Only finished granite work shall be measured). The rate includes rounding, champhering and mirror polishing of edges. The work shall be carried out as per the approval of architect and engineer-in-charge. The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing & laying 18 to 20 mm thick both side polished granite of approved shade and quality, seleted and sorted for uniform color for urinal, platform as per design and in required sizes and shapes over required size of cement mortar bedding in 1:3. (Only finished granite work shall be measured). The rate includes rounding, champhering and mirror polishing of edges. The work shall be carried out as per the approval of architect and engineer-in-charge.

Cuting, Transporting and Fixing granite cobbles of size 150mm x 150mm of thickness 100mm from stones available at site as per design and drawing over 50 mm thick coarse sand bedding (cushioning layer), having compacted sub-base (in required slope and of specified thickness as per drawing - to be paid under relevant item). Joints are to be filled with cement mortar (1:10). Sample to be approved by the Architect before executing the mass area. The work shall be carried out as per the approval of architect and engineer-in-charge. The rate shall be inclusive of collecting the stones / boulders from anywhere within site, installing, operating and maintaining stone cutting machine, cutting the stone as per required size and shape, transporting the finished stones to required location, providing coushion layer of coarse sand, fixing the granite cobbles and filling of the joints but exclusive of preparing layer of subbase.

Providing and fixing 60 mm thick abrasion resistant interlocking or Brick type paver blocks of M40 grade of approved make and colour as per design including average 50 mm coarse sand bedding over compacted sub-base (in required slope and of specified thickness). Sample to be approved by the Architect & Engineer-in-charge. Rate shall be exclusive of sub-base

Page 9: SPCL Offer 9(New)_03.12.09

Page 9 of 53

Sr. N0. Item description Unit Quantity Rate Amount

9.29.a Sqm 200 456 91,200

Rates in Words:

9.33 Sqm 1,659 2,190 3,633,210

Rates in Words:

9.34.a Cum 3,548 4,345 15,416,060

Rates in Words:

9.34.b Sqm 26,213 122 3,197,986

Rates in Words:

9.35.a Sqm 2,680 1,777 4,762,360

Rates in Words:

9.35.b Sqm 2,680 201 538,680

Rates in Words:

9.38 Sqm 1,050 5,729 6,015,450

Rates in Words:

9.39 Sqm 21,870 1,064 23,269,680

Rates in Words: 9.40 Rmt 460 5,602 2,576,920

9.41 Sqm 12,728 2,614 33,270,992

Rates in Words:

Sum Carried over to Summary page 237,142,265

SECTION 10-STRUCUTRAL STEEL WORK

10.01.a

10.01.a.1Rolled steel sections (equal and unequal angles, flats, angles, tees, channels, plates of different sizes etc.), Solid flats, bars chequered plate etc.

Kg 119,310 71 8,471,010

Rates in Words: 10.01.a.2 RHS, SHS, tubular hollow sections having Yst (yield strength) 310 Mpa and specified thickness as per drawing Kg 68,263 74 5,051,462

Rates in Words:

10.02

10.02.1 Sqm 100 222 22,200

Rates in Words: 10.02.2 Sqm 1,080 281 303,480

Rates in Words:

10.03

10.03.1 Sqm 10 3,101 31,010

Rates in Words: 10.03.2 Sqm 10 4,652 46,520

Rates in Words:

10.04

10.04.1 Sqm 40 3,852 154,080

Rates in Words: 10.04.2 shutter shall be partly grilled and partly paneled, mechanically operated with a pair of handles. Sqm 10 5,653 56,530

Rates in Words:

10.09

10.09.1 Spiral Railings Kg 3,340 539 1,800,260

Rates in Words:

10.09.2 Railings, gratings, ladder etc. Kg 3,340 539 1,800,260

Rates in Words:

Brick on edge flooring with bricks of class designation 75 including cement slurry, finishing the joints, flush pointing, curing etc. complete as per drawing in cement mortar with F.P.S. bricks. Sample shall be approved by architect and engineer-in-charge

Providing and fixing glass mosaic tiles of approved make and colour as per design in floor, dado in line, level and gradient at all levels and heights in any shape. Chemicals or bonding material for fixing the tiles of size 25mm x 25mm shall be as per manufacturer’s specification. Grouting of the joints to be done with cement grount of matching colour or as directed by manufacturers specification including necessary cleaning with oxalic acid. Sample of material and pattern is approved by engineer-in-charge. The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Providing and laying cement concrete for roads, pavements & floors 100 –150 mm. thick with machine mixed, machine vibrated M20 concrete with minimum cement content 325 kg/cum etc. in required slope and camber as per drawing including giving a floating coat of 1:1 cement mortar, with nominal temperature steel / weld mesh / fibers / dowel bars / tie bars at joints as specified by the Architect/Engineer-in-charge. The rate shall be exclusive of reinforcement steel, weld mesh, fibers, dowel bars etc. and the same shall be paid in relevant tender items. Rate shall be inclusive of concrete (to be laid in alternate panels of 3.75 m X 5.5m) with steel channel formwork. Sieved sand shall be used

Extra for carrying out vaccum dewatering & Power floater treatment in floors, well compacted, mechanically vibrated, finished to required levels, floated with neat cement and power trowelled to get desired smooth finishing/broom finish, over a levelling course, including MS shuttering, curing for 10 days with gunny bags etc complete. The suitable size of panel should be approximately 3.75 x 5.5 m or as directed by Engineer. The Construction joints to be formed at every 5m distance by grooving with mechanical saw within 48 hrs. Groove/sawed joints shall be made of 6mm width and 25 mm depth min as shown in the drawing. The rate shall be inclusive of labour, grooves and machinery cost.

Providing and laying Non Cushion Synthetic Floor system of Sports Master or equivalent in 4 layers, consisting of two layer of leveling course of level master make or equivalent and two layers of approved shade Acrylic paint and marking of lines with white paint of colour plus make or equivalent as per the manufacturer’s guideline in line, level and gradient to the satisfaction of Engineer-In-Charge including the cost of base course specified under section a to c below.

EXTRA for Synthetic floor with 6 layer cushion system, consisting of one layer of leveling course of level master make or equivalent, three cushion layer of cushion master make or equivalent, two layers of approved shade Acrylic paint and marking of lines with white paint of colour plus make or equivalent as per the manufacturer’s guideline in line, level and gradient to the satisfaction of Engineer-In-Charge.

Providing and fixing outdoor wood floor IPE - Smooth version of size 300X300X30mm of approved make Takettt or equivalent as per manufacture’s specification. Floor is to be laid over the polypropylene patenet grid as per manufacture’s specification and as directed by engineer in charg

Providing and laying in position clay tiles of size 200 mm X 80 mm as per approved sample, as per design and drawing on exterior wall as cladding. Tile is to be fixed over 15 mm thick wired finish plaster in cement mortar 1:4 (1 cement : 4 coarse sand). Tile shall be fixed with 1:1 cement sand mortar of average 6 mm thickness with bonding agent / integral tile adhesive of approved make of behind the tiles including keeping the groove of (5mm x 5mm) with PVC spacer of approved make and grouting in grooves (5mm width x 5mm deep) with cementitious grout of matching shade etc. complete as directed by engineer-in-charge. Rate is inclusive of back coat of 12 to 15 mm thick plaster with polypropelelne fibers, grouting with cementitious grout.

Providing & laying sandwich platform comprising of

Providing & fixing stone cladding on wall for all heights with natural finish “AGRA RED" stone, 30 mm thick having maximum size of 1200x600 mm with grooves (10mm x 10mm) in both direction, filling the grooves with epoxy grout (10mm x 5mm) of matching shade as per detail design and drawing. The stone shall be fixed with stainless steel clamps (304 grade) of approximate size 100x20x4mm (LxWxthick) inserted in the wall, curing etc. complete. The rate shall also include backing coat wired finish plaster of average 15 mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) with polyproplene fibers (----gms per 1 cement bag) of approved make, grouting the clamps in brick wall with non shrink cement mortar and anchor fasteners for RCC surfaces, etc. complete. The work shall be carried out as per the cladding sample approved by Architect and engineer in charge.

Structural steel work in riveted, bolted or welded in built up sections, trusses and framed work including supplying, fabricating, cutting, assembling, hoisting and fixing in position at all heights of all shapes and size with all leads and lifts as per latest IS 4923, IS 1161, IS 806 for the work of sheds, canopy, trusses, space frame, cladding, skylight, monkey ladder, staircase, railing, gate, insert plate, cattle trap etc. It should be including necessary rolled joists, channels, angles, tees, flats, angle cleats, gusset plates, position hip and jack lifters, purlins, etc. including cutting and welding the members as per detailed drawing and design. The rate shall include 1 coat of Rustocap and 2 coat of Hi-Gloss Metal PU Paint of Asian paint over all the surfaces of the steel sections or as specified in the drawing. (Only standard measurements will be paid for as actual cut length used at site). Shop drawings for the connection details shall be prepared for the approval of the architect.

Rate shall be inclusive of cutting, wastage, welding, bending (shop at site), bolting wherever necessary, in position welding of required length, grinding, finishing edges, filling the welded spots with metal putty. It should also include the cost of approved ISI make and size zinc coated nut-bolt and Anchor fasteners of Hilti or Fisher as approved by engineer-in-charge

Contractor should submitted fabrications shop drawings for work involved based on construction drawings (that may be issued during construction period) for approval by Engineer-in-charge. The fabrication work shall start after approval by Architect of the fabrication drawings. Any change required in fabrication drawings shall be carried out at no extra cost over quoted rates. Fabrication works to be carried out as per relevant IS standards.

Providing, fabricating and fixing MS jali including cutting and welding the members as per detailed drawing and design and as directed by engineer-in-charge. The rate shall include 1 coat of Rustocap and 2 coat of Hi-Gloss Metal PU Paint of Asian paint over all the surfaces or specified by engineer-in-charge of approved make over a 2 coats of zinc chromate yellow oxide primer. (Actual measurement shall be paid for).

MS Weld mash jali (25mm x 25mm size of 12 guage)

GI Chain Link Jali (50mm x 50mm size of 10 guage)

Providing and fixing in position, interlocking rolling shutter of approved make, of 18 gauge, 75mm wide cold rolled MS lath interlocked, including top cover, spring, axles, guide rails, tees, iron pulleys, bearings, handles, holding down bolts embedded in CC 1:2:4 including1 coat of Rustocap and 2 coat of Hi-Gloss Metal PU Paint of Asian paint over all the surfaces etc. as directed. (Measurements considered for payments shall be clear size of opening plus guide channels on both the sides for width and 450mm on top for drum height.)

With push and pull arrangement.

With mechanical device with a pair of handles

Providing and fixing in position, interlocking rolling shutter of approved make, of 18 gauge, 75mm wide cold rolled MS lath interlocked, including top cover, spring, axles, guide rails, tees, iron pulleys, bearings, handles, holding down bolts embedded in CC 1:2:4 including 1 coat of Rustocap and 2 coat of Hi-Gloss Metal PU Paint of Asian paint over all the surfaces etc. as directed. (Measurements considered for payments shall be clear size of opening plus guide channels on both the sides for width and 450mm on top for drum height.)

Shutter shall be partly grilled and partly paneled and pull and push type.

Fabricating and fixing SS railing of 304 grade made out of round pipes, square or rectangle sections in satin / brush finish with supporting fittings made out of SS 304 grade fixing with mechanical anchor fastener of stainless steel etc. on concrete surface, brick surfaces or floor including bending and bends as per the drawing with best quality finish as per the approval of Architect and as directed by engineer-in-charge.

Page 10: SPCL Offer 9(New)_03.12.09

Page 10 of 53

Sr. N0. Item description Unit Quantity Rate Amount

10.10 Cum 14 120,553 1,687,742

Rates in Words:

Sum Carried over to Summary page 19,424,554

SECTION 11-PAINTING WORK

11.01.a Sqm 100 44 4,400

Rates in Words:

11.03.a Sqm 82,793 113 9,355,609

Rates in Words:

11.03.b Sqm 45,265 144 6,518,160

Rates in Words:

11.05.a Sqm 2,427 129 313,083

Rates in Words:

11.06 Sqm 0 407

Rates in Words:

11.08

11.08.1 Exposed concrete surface Sqm 31,871 78 2,485,938

Rates in Words: 11.08.2 Exposed Brick surface Sqm 100 98 9,800

Rates in Words: 11.08.3 Clay tile cladding Sqm 21,870 98 2,143,260

Rates in Words: 11.08.4 Agra stone cladding Sqm 12,728 89 1,132,792

Rates in Words:

11.25 Sqm 62,694 182 11,410,308

Rates in Words:

Sum Carried over to Summary page 33,373,350

SECTION 15-GENERAL DEVELOPMENT WORK

15.02 Cum 1,103 135 148,905

Rates in Words:

15.17 Rmt 5,882 446 2,623,372

Rates in Words:

15.18 Rmt 12,819 665 8,524,635

Rates in Words:

15.19 Cum 50 1,110 55,500

Rates in Words:

15.20 Sqm 420 648 272,160

Rates in Words:

15.21 Sqm 10,057 56 563,192

Rates in Words:

15.22 Sqm 4,646 267 1,240,482

Rates in Words:

15.23 Sqm 79 698 55,142

Rates in Words:

15.24 Rmt 100 422 42,200

Rates in Words:

15.25 Sqm 1,300 4,974 6,466,200

Providing and fixing teak wood hand rail of the specified size and shape as per the detail design over the MS / SS fabrication and railings installed, including 3 coats PU polishing of approved make, shade etc. as directed by engineer in charge. The teak wood shall be first class Ghana teak wood.

White wash with lime on any surfaces (3 coats with brush) to give an even shade at all heights and all levels., including thoroughly brooming the surface to remove all dirt, dust, mortar drops and other foreign matter etc. complete.

Providing and applying three coats of plastic emulsion paint of approved make, colour & shade (first two coats with brush and final coat with roller), on newly dry interior plastered surface at all heights give an even shade, including white cement based putty of Birla white or equivalent after thoroughly brushing the surfaces free from mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth etc. after applying every coat of putty. Priming coat of cement primer (water or solvent based) is to be applied on putty etc. complete as directed by engineer-in-charge. Sample to be approved before starting of the work. The rates shall include the cost of filler for filling the cracks on surface.

Providing and applying three coats (first two coats with brush and final coat with roller) of pearl lusture paint of approved make, color & shade), on newly dry interior plastered surface at all heights give an even shade, including white cement based putty of Birla white or equivalent after throughly brushing the surfaces free from mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth etc. after applying every coat of putty. Priming coat of cement primer (water or solvent based) is to be applied on putty etc. complete as directed by engineer-in-charge. Sample to be approved before starting of the work. The rates shall include the cost of filler for filling the cracks on surface.

Providing & applying External 100% Acrylic Paint of desired shed from Apex of Asian paint or equivalent in minimum three coats to give an even shade with brush on exterior sand faced plastered surfaces / mala plastered surfaces or any surfaces at all heights including scaffolding, thoroughly brushing the surfaces with sand paper to make it free from mortar dropping and other foreign matter etc. complete as per the manufacture's specification and up to the satisfaction of Engineer in charge. The rate shall also include the cost of filler for cracks on the surfaces.

Providing and applying External finish of average 1.5 to 2 mm thick acrylic polymer based texture of "Ruff & Tuff" finish of NITCO, or equivalent make with standard tool and applicator as specified by company, on exterior surfaces at all heights including scaffolding to give even shades including througly brushing the surfaces free from mortar droping and other foreign matter and sand papared smooth with two coats 100% Acrylic Paint etc complete as per the manufacture specifications and to the satisfaction of Engineer In charge or architect. The rate includes making of grooves, pattas etc. and finishing.

Providing and applying solvent based Silicone paint as directed with a minimum 5 years guarantee on stamp paper to the employer directly. (The Contractor should specify the % concentration of silicone while quoting the rate.)Minimum 7 % concentration of silicone shall be manintained while diluting with additives.

Providing and applying 6 mm to 8mm POP punning of JK Lakhmi Cement or equivalent over plastered surface at all levels including thoroughly brushing the surface free from mortar dropping and other foreign matter, preparing the surface even and sand papered smooth etc. complete to receive the coat of painting as directed by engineer in charge.

Box cutting the road surface, to proper slope and camber, for making a base for road work, including rolling, removing the excavated stuff and depositing as directed anywhere within site, etc. complete as directed by engineer-in-charge.

Providing and laying cast in situ RCC M20 curbing of approximate size of 40cm height X 15cm wide, including necessary excavation and backfilling, laying 75 mm thick PCC 1:5:10 (1 part cement : 5 parts sand : 10 parts stone aggregate 20/37 mm. down size), exposed shuttering, rendering, curing, filling in the joints with rich cement mortar but excluding reinforcement as directed etc. complete as per the details and drawings and as directed by engineer-in-charge

Providing and laying Precast RCC M20 curbing of approximate size of 60cm height x 40cm wide X 15cm thickness, including necessary excavation and backfilling, laying 75 mm thick PCC 1:5:10 (1 part cement: 5 parts sand: 10 parts stone aggregate 20/37 mm. down size), exposed shuttering, rendering, curing and filling bituminous mastic in expansion joints but excluding reinforcement as directed etc. complete as per the details and drawings and as directed by engineer-in-charge

Providing and laying metal soling in a compact manner for granular sub-base in single layer including supplying and spreading of large size machine cut stone aggregates 40 mm.and down size, spreading the same in required grade and camber in one or more layer. Filling the voids with good quality murrum to make plain surface, profusely watering including consolidating by power driven roller of 8 to 10 ton capacity in required camber, dry and wet rolling etc. complete as directed by engineer-in-charge.

Providing & marking 10/15 cms wide 2.5 mm thick thermoplastic patta of yellow or white on the road surface etc. comp. As. Directed. Rate includes brushing, brooming & cleaning and application of paint.

Providing and laying brickbat chharu over sub base including spreading in uniform layer of 50 mm thickness, consolidating with plate compacter, watering and finishing in level and slope as shown in the drawing or as directed by Engineer-In-Charge.

Pitching with available stones of minimum size 150x150 mm in elevation at site in slope and floor as required according to site condition to stop erosion including filling the joints and pointing with cement mortar 1:6 as approved by Architect and directed by engineer in charge. Rate includes dressing and cleaning of the existing surface.

Providing & marking Zebra Crossing, Straight and turning arrows and STOP or other letters with 2.5 mm thick thermoplastic paint of yellow or white on the road surface etc. comp. As. Directed. Rate includes brushing, brooming & cleaning and application of the paint.

Cuting, Transporting and Fixing granite cobbles curbing of size (300mm wide x 300 mm height x 150 mm thick) including necessary excavation and backfilling, laying 75 mm thick PCC 1:5:10 (1 part cement: 5 parts sand: 10 parts stone aggregate), filling in joints with rich CM etc. complete as per the details and drawings and as directed by engineer-in-charge. The rate shall be inclusive of collecting the stones / boulders from anywhere within site, installing, operating and maintaining stone cutting machine, cutting the stone as per required size and shape, transporting the finished stones to required location, fixing the granite cobbles with CM, filling of the joints, earth work and laying PCC etc. complete.

Providing and installing Textile Architecture for stadiums, stands, shoppings, logistic centres, walkways, carparking, swimming pool etc. by using FERRARI or equivalent composite membrane made up of weave of high-tenacity polysester base yarn material of approved shade and quality by Architect and Engineer-in-charge . The material should have properties like long lasting mechanical resistance, dimensional stability, flexiblity, non fading, UV resistant, flame retardant, ease of fitting. The material shall be delivered in manufacture's original unopened containers and packaging with labels clearly identifying product name and manufacturer. It should be stored in dry and clean indoor areas and handling in such a way to prevent damage in accordance with manufacture's instructions. Contractor shall submit manufacturer's maintenance and cleaning manual, manufacurer's certificate etc. Work shall be executed as per the drawing in best workmanship manner upto the satisfaction of Architect or Engineer-in-charge.

Page 11: SPCL Offer 9(New)_03.12.09

Tender DocumentsAga Khan Academy, Hyderabad

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 11 of 53

SUMMARY OF PLUMBING WORKS

Sr. No. Description Total Amount (Indian Rupees)

1 Section 01 14,481,041

2 Section 02 20,645,479

3 Section 03 4,161,815

4 Section 04 9,400,925

5 Section 05 28,055,221

Total Amount: 76,744,481

Amount in Words:

Signature of Authorised Signatory Stamp of the Bidder

Page 12: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 12 of 53

BILL OF QUANTITIES - PLUMBING WORKS

Sr. No. Item Description Unit Quantity Rate Amount

SECTION - 1.00

1.01.a

1) 100 mm rmt 8 1 183 9,464

Rate in words:

2) 80 mm rmt 535 821 439,235

Rate in words:

3) 65 mm rmt 1,615 652 1,052,980

Rate in words:

4) 50 mm rmt 1,986 519 1,030,734

Rate in words:

5) 40 mm rmt 1,488 378 562,464

Rate in words:

6) 25 mm rmt 3,108 245 761,460

Rate in words:

7) 20 mm rmt 710 175 124,250

Rate in words:

8) 15 mm. rmt 3,157 139 438,823

Rate in words:

1.01.b

1) 100 mm rmt 0 1 183

Rate in words:

2) 80 mm rmt 0 821

Rate in words:

3) 65 mm rmt 50 652 32,600

Rate in words:

4) 50 mm rmt 46 519 23,874

Rate in words:

5) 40 mm rmt 1,361 378 514,458

Rate in words:

6) 25 mm rmt 1,776 245 435,120

Rate in words:

7) 20 mm rmt 412 175 72,100

Rate in words:

8) 15 mm. rmt 2,710 139 376,690

Rate in words:

Providing and fixing galvanized iron (GI) mild steel tube (Heavy grade Class C) of Tata make, conforming to IS: 1239, including tube fittings of R Brand such as sockets, unions, reducers, long or short bends, elbows, nipple, flanges, check-nuts, tees, etc., complete (in proper line and level, with necessary supports viz., clamps of Chilly make with m.s.brackets, RCC or brick masonry pedestals and battens, if required) jointing with screw joints, using hold tight and jute for pipes and Teflon tape for fittings and fixtures, open laid to wall, ceiling and floor including making them good, testing and wrapping the pipes and fittings with Hessian cloth and painting with 2 coats of approved paint etc complete to the satisfaction of EIC of the following nominal bore (NB) size:

Providing and fixing galvanized iron (GI) mild steel tube (Heavy grade Class C) of Tata make, conforming to IS: 1239, including tube fittings of R Brand such as sockets, unions, reducers, long or short bends, elbows, nipple, flanges, check-nuts, tees, etc., complete (in proper line and level, with necessary supports viz., clamps of Chilly make with m.s. brackets, RCC or brick masonry pedestals and battens, if required) jointing with screw joints, using hold tight and jute for pipes and Teflon tape for fittings and fixtures, Concealed laid to wall, ceiling and floor including making jaries and refinished jaries, testing and wrapping the pipes and fittings with Hessian cloth and painting with 2 coats of approved paint etc., complete of the following nominal bore (NB) size:

Page 13: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 13 of 53

Sr. No. Item Description Unit Quantity Rate Amount

1.03.b

1) 40 mm rmt 97 384 37,248

Rate in words:

2) 25 mm rmt 2,306 239 551,134

Rate in words:

3) 20 mm rmt 818 315 257,670

Rate in words:

4) 15 mm. rmt 2,829 286 809,094

Rate in words:

1.03.c

1) 40 mm rmt 0 286

Rate in words:

2) 25 mm rmt 8 204 1,632

Rate in words:

3) 20 mm rmt 412 145 59,740

Rate in words:

4) 15 mm. rmt 1,220 116 141,520

Rate in words:

1.04.a

1) 80 mm no. 18 6 798 122,364

Rate in words:

2) 65 mm no. 14 5 044 70,616

Rate in words:

3) 50 mm no. 101 5 283 533,583

Rate in words:

4) 40 mm no. 145 1 800 261,000

Rate in words:

5) 25 mm no. 369 1 136 419,184

Rate in words:

6) 20 mm no. 4 827 3,308

Rate in words:

7) 15 mm no. 84 588 49,392

Rate in words:

1.05.a

1) 25 mm no. 157 717 112,569

Rate in words:

2) 20 mm no. 4 542 2,168

Rate in words:

3) 15 mm no. 63 384 24,192

Rate in words:

1.05.b

1) 50 mm no. 5 9 418 47,090

Providing and fixing insulation to hot water open pipe on walls with Pipe shall be wrapped around with Glass wool - Resin bonded mattresses of rock wool min. 50 mm thick, 100 Kg/Cu.M density, binding with 20 SWG GI chicken mesh complete covered by 24 SWG aluminum cladding duly screwed / rewetting etc. including all joints of insulation foil shall be sealed with silicon sealant, end joints shall be jointed with silicon sealant etc. Including supply, fabricating m.s. support / clamps as per drawing etc. complete over GI lines for hot water supply etc., complete, of the following nominal bore (NB) size

Providing and fixing insulation to small pipes embedded in walls, with 6 mm. thick asbestos rope of Champion make or approved equivalent on GI lines for Concealed hot water supply, etc complete to the satisfaction of EIC of the following nominal bore (NB) size:

Providing, fixing and testing, heavy quality gun metal or brass gate full way wheel valve of Zoloto / Leader make with screwed/flanged ends, factory tested at 20 kg/m2., on GI lines etc complete to the satisfaction of EIC of the following nominal bore (NB) size:

Providing, fixing and testing, heavy quality gun metal or brass non-return swing type valve Zoloto / Leader make, with screwed/flanged ends, factory tested at 20 kg/cm2.,etc complete to the satisfaction of EIC of the following nominal bore (NB) size:

Providing, fixing and testing, heavy quality gun metal or brass Air Release Valve of Harit make, with screwed/flanged ends, factory tested etc complete to the satisfaction of EIC of the following nominal bore (NB) size:

Page 14: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 14 of 53

Sr. No. Item Description Unit Quantity Rate Amount

Rate in words:

2) 25 mm no. 5 3 297 16,485

Rate in words:

1.05.c

1) 80 mm no. 5 6 693 33,465

Rate in words:

2) 65 mm no. 3 5 230 15,690

Rate in words:

3) 50 mm no. 9 3 734 33,606

Rate in words:

4) 40 mm no. 32 2 185 69,920

Rate in words:

5) 25 mm no. 0 1 112

Rate in words:

6) 15 mm no. 0 542

Rate in words:

1.9.a no. 121 1 200 145,200

Rate in words:

1.9.b no. 65 1 083 70,395

Rate in words:

1.16.a

1) 300 mm mtr 25 7 793 194,825

Rate in words:

2) 150 mm mtr 214 3 239 693,146

Rate in words:

3) 80 mm mtr 30 1 725 51,750

Rate in words:

1.17.a

1) 300 mm no. 1 43 664 43,664

Rate in words:

2) 250 mm no. 2 34 005 68,010

Rate in words:

3) 200 mm no. 1 22 629 22,629

Rate in words:

Providing, fixing and testing, heavy quality gun metal or brass ball cock heavy duty of approved make with screwed ends, factory tested at 20 kg/m2., etc complete to the satisfaction of EIC on GI lines of the following nominal bore (NB) size:

Labour charges for fixing a Water Purifier / RO plant or equivalent, including supply and fixing 1 no. angle valve of Jaquar make Florentine series Cat. No. 5053, with CP copper pipe inlet and outlet connections, including all other electrical accessories supplied/listed by the manufacturer, etc complete to the satisfaction of EIC and as per the drawing/layout.

Labour charges for fixing a Water Cooler, including supplying and fixing 1 no angle valve and CP copper pipe inlet connection and GI outlet pipe, including fixing electrical accessories supplied/listed by manufacture etc complete to the satisfaction of EIC

Providing and fixing in proper line and level, (including necessary support like CI clamps, MS flats, RCC or brick masonry pedestals and battens if required), cast iron LA class flanged end pipe of Electro Steel Casting / Kapilanesh make, open to wall, ceiling and floor, of approved make, including tube fittings such as sockets, reducers, long or short bends, flanges, m.s. puddle flanges, tees etc., complete including making good the wall, ceiling, and floor, jointing with lead caulked joints, testing and painting the pipes and specials with minimum 2 coats of approved bitumastic paint over one coat of primer etc., complete as per the specification and as directed by the Engineer-in-charge. (RCC or brick pedestals, if any, shall be measured and paid in the relevant tender items). The diameter of pipe shall be of the following NB:

Providing and fixing flanged mount CI sluice valve of Zoloto / Leader make with GM seats, high tensile brass spindle with cap, conforming to standard water-works pattern and flanges as per IS: 15381, flat faced and drilled, etc complete to the satisfaction of EIC with accessories of the following pipe dia:

Page 15: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 15 of 53

Sr. No. Item Description Unit Quantity Rate Amount

4) 150 mm no. 2 12 675 25,350

Rate in words:

5) 100 mm no. 5 8 941 44,705

Rate in words:

1.19.b

1) 355 mm OD rmt 140 4 525 633,500

Rate in words:

2) 280 mm OD rmt 140 3 599 503,860

Rate in words:

3) 225 mm OD rmt 75 2 406 180,450

Rate in words:

4) 160 mm OD rmt 745 1 287 958,815

Rate in words:

5) 110 mm OD rmt 1,042 711 740,862

Rate in words:

6) 90 mm OD rmt 963 466 448,758

Rate in words:

7) 75 mm OD rmt 275 368 101,200

Rate in words:

8) 63 mm OD rmt 25 280 7,000

Rate in words:

Sum Carried over to Summary page 14,481,041

Section - 2.00

2.04.a no. 333 19 635 6,538,455

Rate in words:

2.04b no. 72 30 773 2,215,656

Rate in words:

Providing and fixing underground or below floor, high density Polyethylene (HDPE) pipes of Hasti make Schedule PE - 80 (for water supply purpose) and all type of fittings readymade of Hasti make or approved moulded fabricated, including jointing using butt welding, testing, etc. complete, with a working pressure of 6 Kg/m2. etc complete to the satisfaction of EIC (Earthwork and filling, sand filling and Concrete thurst block shall be paid extra in relevant tender Items.) of following size :

Providing and fixing ivory glazed vitreous chinaware extended wall mounted cantilever type EWC of Hindustan make Cat No 20048 Crystal + 21032 with ceramic attached cistern, seat cover, cistern fittings, CI chair bracket with rag bolt and GI 12mm rag bolt with nut and metal washer(pair) etc including supply and fixing of 1 no CP heavy duty angle valve with CP wall flange of Jaquar make Florentine series Cat. No. 5053 with CP brass inlet connection with integral `P' or `S' trap including cutting and making good the wall and floor as under with supported on CI wall brackets etc. complete to the satisfaction of EIC

Providing and fixing Starwhite glazed vitreous chinaware Sets for the Paraplegic of Hindustan make Cat No 70003 Matrix set-2 - including - Wash Basin MATRIX-10060 (size 450mm x 280 mm ) with one pair mounting brackets, EWC MATRIX-20049, Cistern ABIGAIL-21030 complete with fittings and seat cover, one hinged rail of 76 cms, four (4 nos) of grab rails of 60 cms and one no. of faucet for wash basin with 2 no. of CP heavy duty angle valve with CP heavy flange of Jaquar make Florentine series Cat No. 5053 with 2 nos copper connections all required hardwares etc. complete with integral `P' or `S' trap including cutting and making good the wall and floor etc complete to the satisfaction of EIC

Page 16: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 16 of 53

Sr. No. Item Description Unit Quantity Rate Amount

2.08a

no. 30 4 100 123,000

Rate in words:

no. 124 6 483 803,892

Rate in words:

2.08b

no. 99 4 229 418,671

Rate in words:

no. 174 6 757 1,175,718

Rate in words:

2.10.a. no. 76 12 827 974,852

Rate in words:

2.10.b. no. 41 11 568 474,288

Rate in words:

Providing and fixing ivory glazed vitreous chinaware wash basin of Hindustan make with single or double hole for pillar-tap comprising of: a) Ivory glazed vitreous chinaware washbasin, with supporting MS or CI brackets. b) 1 no. 40 or 32mm CP cast brass bottle-trap of Jaquar make Allied series Cat. No. 769 with extension piece to wall, wall flange with rubber adopter for waste connection and one waste coupling. c) 1 no. heavy quality CP brass angle valve with wall CP flange of Jaquar make Florentine series Cat. No. 5053, 15mm size. d) 1 no. 15mm NB heavy quality CP-brass inlet connection with unions at end. The supporting bracket shall be painted with 3 coats of approved paint of approved shade etc. complete to the satisfaction of EIC in following size:

i) 560 mm x 450 mm - Hindustan make Cat. No. 10008 VIKING

ii) 630 mm x 500 mm (oval-under counter type). - Hindustan make Cat. No. 10045 RAPHSODY

Providing and fixing Ivory glazed vitreous chinaware wash basin of Hindustan make with single or double hole for pillar-tap comprising of: a) Ivory glazed vitreous chinaware washbasin, with supporting MS or CI brackets. b) 1 no. 40 or 32mm CP cast brass bottle-trap of Jaquar make Allied series Cat. No. 769 with extension piece to wall, wall flange with rubber adopter for waste connection and one waste coupling. c) 2 nos. heavy quality CP brass angle valves with wall CP flange of Jaquar make Florentine series Cat. No. 5053, 15mm size. d) 2 nos. 15mm NB heavy quality CP-brass inlet connection with unions at end. The supporting bracket shall be painted with 3 coats of approved paint of approved shade etc. complete to the satisfaction of EIC. in following size:

i) 560 mm x 450 mm - Hindustan make Cat. No. 10008 VIKING

ii) 630 mm x 500 mm (oval-under counter type). - Hindustan make Cat. No. 10045 RAPHSODY

Providing and fixing a stainless steel sink of Nirali make, single bowl of size not more than 610 mm x 460 mm and depth 254 mm, comprising of: a) stainless steel sink supported on MS or CI brackets. b) 1 no. 40 or 32mm CP cast brass bottle-trap of Jaquar make Allied series Cat. No. 769 with extension piece to wall, wall flange with rubber adopter for waste connection and one waste coupling. c) 1 no. heavy quality CP brass angle valves with wall CP flange of Jaquar make Florentine series Cat. No. 5053 15 mm size. d) 1 no. 15 mm NB heavy quality CP-brass inlet connection with unions at end. The supporting bracket shall be painted with 3 coats of approved paint of approved shade etc. complete to the satisfaction of EIC

Providing and fixing a stainless steel sink of Nirali make, single bowl with drain board of overall size 1000 mm x 510 mm and depth 175 mm, comprising of: a) stainless steel sink supported on MS or CI brackets. b) 1 no. 40 or 32mm CP cast brass bottle-trap of Jaquar make Allied series Cat. No. 769 with extension piece to wall, wall flange with rubber adopter for waste connection and one waste coupling. c) 1 no. heavy quality CP brass angle valves with wall CP flange of Jaquar make Florentine series Cat. No. 5053 15 mm size. d) 1 no. 15 mm NB heavy quality CP-brass inlet connection with unions at end. The supporting bracket shall be painted with 3 coats of approved paint of approved shade etc. complete to the satisfaction of EIC

Page 17: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 17 of 53

Sr. No. Item Description Unit Quantity Rate Amount

2.11.a no. 369 862 318,078

Rate in words:

2.11.b no. 24 815 19,560

Rate in words:

2.12.a no. 111 903 100,233

Rate in words:

2.13.a no. 286 2 691 769,626

Rate in words:

2.13.b no. 43 9 174 394,482

Rate in words:

2.14 no. 125 1 334 166,750

Rate in words:

2.15 sqm 355 693 246,015

Rate in words:

2.16.b no. 436 740 322,640

Rate in words:

2.16.c no. 269 2 458 661,202

Rate in words:

2.16.d no. 378 560 211,680

Rate in words:

2.17.b no. 378 909 343,602

Rate in words:

2.18.a no. 436 1 410 614,760

Providing and fixing screw down brass chromium plated heavy quality bib-tap of Jaquar make Florentine series Cat. No. 5037 on water supply pipe lines of 15mm dia with or without extension piece but with a flange etc. complete to the satisfaction of EIC

Providing and fixing, screw down brass chromium plated long body bib taps, of Jaquar make Continental series Cat. No. 107 heavy quality, of approved make, on GI lines, of 15 mm. dia., with or without extension piece and flange etc complete to the satisfaction of EIC

Providing and fixing brass chromium plated heavy quality pillar-tap/cock of Jaquar make Florentine series Cat No. 5011 on water supply pipelines of 15mm dia with or without extension piece but with a flange etc complete to the satisfaction of EIC

Providing and fixing brass chromium plated heavy quality wash basin mixer pillar-tap/cock of Jaquar make Florentine series Cat No. 5167 on water supply pipelines of 15mm dia with or without extension piece but with a flange, etc., complete to the satisfaction of EIC.

Providing and fixing brass chromium plated heavy quality Wash basin sensor of Jaquar make series Cat No. 51021 on water supply pipelines of 15mm dia with or without extension piece but with a flange, etc., complete to the satisfaction of EIC

Providing and fixing 15mm NB CP brass heavy quality wall or floor mounted sink tap, swivel type, with CP wall flange, casted spout of Jaquar make Florentine series Cat. No. 5357 etc. complete to the satisfaction of EIC

Providing and fixing best Indian make mirror of specified size like Modi float, Sain Gobin, I.A.G or equivalent silvered locally, with plain edge as required, with 12mm thick marine plywood backing, with CP brass caps, etc., complete. Teakwood beading of 20mm x 32mm size, with French polish or 3 coats of paint etc. complete to the satisfaction of EIC

Providing and fixing a CP brass Towel-ring of Jaquar make Continental series Cat. No. 1121 with concealed type brackets fixed to the wall with CP brass screws, etc., complete to the satisfaction of EIC

Providing and fixing a CP towel-rack, 230 x 600mm size of Jaquar make Continental accessories Cat. 1181 with concealed type brackets fixed to the wall with CP brass screws, etc., complete to the satisfaction of EIC

Providing and fixing SS or brass chromium plated double Robe hook of Jaquar make Continental series Cat. 1161 as per the design and specifications, etc., complete to the satisfaction of EIC

Providing and fixing a screw-to-wall type toilet paper-roll holder fixed to the wall with CP brass screws, of Jaquar make Continental series Cat. No. 1153 complete to the satisfaction of EIC

Providing and fixing soap dispenser of Jaquar make Continental series Cat. No. 1137 metallic liquid soap dispenser with SS pump, cap and CP heavy duty bracket, fixed to wall with CP brass screw, etc., complete to the satisfaction of EIC

Page 18: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 18 of 53

Sr. No. Item Description Unit Quantity Rate Amount

Rate in words:

2.18.c no. 273 856 233,688

Rate in words:

2.19.b.2 no. 31 1 060 32,860

2.19.c.1 no. 84 838 70,392

Rate in words:

2.20.a no. 203 1 439 292,117

Rate in words:

2.20.b no. 70 1 753 122,710

Rate in words:

2.21.a no. 70 3 274 229,180

Rate in words:

2.21.b no. 172 2 790 479,880

Rate in words:

2.22 no. 52 13 135 683,020

Rate in words:

2.35.a no. 8 11 713 93,704

Rate in words:

2.35.b no. 62 11 470 711,140

Rate in words:

2.39 no. 378 2 126 803,628

Rate in words:

Sum Carried over to Summary page 20,645,479

Section - 3.00

Providing and fixing a surface type soap dish / tray of Jaquar make Continental series Cat. No. 1131 complete with clean surface to original conditions, etc., complete to the satisfaction of EIC

Providing and fixing a heavy quality CP brass stopcock (concealed with sheet flange) of 15mm dia. of Jaquar make Cat. No. 5083 on water supply pipe lines etc. complete to the satisfaction of EIC

Providing and fixing a heavy quality CP brass angular stopcock of Jaquar make Florentine series Cat. No. 5053 (male or female end) of 15mm dia on water supply pipe lines etc. complete to the satisfaction of EIC

Providing and fixing a 15mm dia inlet pressure adjustable shower rose with cast shower arm of size 230 mm and flange of Jaquar make Florentine series Cat No. 5489 etc. complete to the satisfaction of EIC

Providing and fixing Telephone shower with 1.5 Mtr long flexible tube swivel wall hook inclusive of all accessories, etc complete of Jaquar make Florentine series Cat. No. 5537 etc. complete to the satisfaction of EIC

Providing and fixing Bath Tub Mixer wall or table top mounted with Telephone shower arrangement for Bath Tub with all accessories such as CP heavy duty flange etc complete of Jaquar make Florentine series Cat. No. 5271 or 5267 etc complete to the satisfaction of EIC

Providing and fixing Hot & Cold wall mixer with provision for overhead shower with 115 mm long bend pipe with all accessories, flange etc complete of Jaquar make Florentine series Cat. No. 5273 etc. complete to the satisfaction of EIC

Providing and fixing a vitreous chinaware ivory urinal of Hindustan make Cat. No. 60010 DYNA with all accessories, including supply and installation of 1 no. of heavy duty CP Urinal sensor with wall plate complete of Jaquar make Cat. No. 51087 with necessary connection etc. complete to the satisfaction of EIC in size mentioned under :

Providing and fixing bath tub of Hindware make "TIFFANY" of size 1670 x 755 x 470 mm including CP heavy duty waste coupling, overflow connecting with 32mm dia copper pipe up to P trap, including all necessary cutting, fixing, brackets etc complete to the satisfaction of EIC (For Guest House and Principal Bungalow)

Providing and fixing bath tub of Hindware make "IRIS" of size 1520 x 730 x 465 mm including CP heavy duty waste coupling, overflow connecting with 32mm dia GI pipe up to P trap, including all necessary cutting, fixing, brackets etc complete to the satisfaction of EIC (For Student Residences and Faculty Residences)

Providing and fixing Hand Shower (Health Faucet) of Jaquar make Allied series Cat. No. 573 with angle valve of Jaquar make Florentine series Cat. No 5053 with CP flange with 8 mm dia., 1 m long PVC tube and wall hook of approved make etc. complete to the satisfaction of EIC

Page 19: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 19 of 53

Sr. No. Item Description Unit Quantity Rate Amount

3.04.a no. 885 169 149,565

Rate in words:

3.05.a no. 123 641 78,843

Rate in words:

3.05.b no. 300 396 118,800

Rate in words:

3.08.a

1) 160 mm (RWP) rmt 1,161 576 668,736

Rate in words:

2) 110 mm rmt 2,832 331 937,392

Rate in words:

3) 90 mm rmt 691 227 156,857

Rate in words:

3.08.b

1) 160 mm (RWP) rmt 60 752 45,120

Rate in words:

2) 110 mm rmt 3,871 384 1,486,464

Rate in words:

3) 90 mm rmt 574 251 144,074

Rate in words:

3.09.a no. 822 419 344,418

Rate in words:

3.09.b no. 62 303 18,786

Rate in words:

Providing and fixing in position a Stainless steel grating, 150mm x 150mm or 150mm dia / square in size, of Chilly make Cat. No. SS006 generally conforming to the drawings and fixed on the inlet pipe etc complete to the satisfaction of EIC

Providing and fixing in position PVC rain water inlets with gravel guard grating of Supreme / Prince make conforming to drawings and fixed on the inlet of 160 mm dia pipe etc complete to the satisfaction of EIC

Providing and fixing in position PVC rain water inlets with gravel guard grating of Supreme / Prince make conforming to drawings and fixed on the inlet of 110 mm dia pipe etc complete to the satisfaction of EIC

Providing and fixing, to wall, ceiling and floor, SWR quality, heavy duty, 6 Kg/cm² working pressure PVC pipes, of Supreme / Prince make, open laid, for Soil / Waste / Rain water etc complete, jointing with rubbering and airtight joints, with necessary specials, bends, such as `Y' junction, `T' junction (both single and double), including plugs, shoes, cowls, flange compression type fittings, wall clips, etc. and lubricant or jointing material, including testing, cutting, making good the wall, ceiling and floor, etc complete to the satisfaction of EIC , The dia. of pipes shall be of the following outer diameter(OD):

Providing and fixing Rigid PVC quality, 6kg /cm² of Supreme / Prince make concealed laid with necessary specials, bends, such as `Y' junction, `T' junction (both single and double), including plugs, shoes, cowls, flange compression type fittings, wall clips, in proper line and level with necessary support like brackets (hot dip galvanized 35X5mm flat) / clamps of chilly make with 3 mm minimum thickness, RCC or brick pedestals or battens, if necessary, to wall, ceiling and floor, open, complete jointing with solvent cement and airtight joints, with ‘T’ shaped rubber ring, , etc., and lubricant or jointing material, including testing, cutting, making good the wall, ceiling and floor, etc complete to the satisfaction of EIC of the following OD

Providing and fixing an SWR quality, heavy duty, uPVC ‘P’ trap of Prince / Supreme make Including cutting the floor and making them good with surrounding M15 CC, masonry supports, MS brackets etc. testing, etc complete to the satisfaction of EIC having 110 mm inlet and 110 mm outlet.

Providing and fixing an SWR quality, heavy duty, uPVC Nahni trap of Prince / Supreme make Including cutting the floor and making them good with surrounding M15 CC, masonry supports, MS brackets etc. testing, etc complete to the satisfaction of EIC having 110 mm inlet and 110 mm outlet.

Page 20: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 20 of 53

Sr. No. Item Description Unit Quantity Rate Amount

3.10 no. 110 116 12,760

Rate in words:

Sum Carried over to Summary page 4,161,815

Section - 4.00

4.01.a.2 rmt 0 699

Rate in words:

4.01.b.1 rmt 22 396 8,712

Rate in words:

4.01.c.1 rmt 290 221 64,090

Rate in words:

4.03.b no. 228 582 132,696

Rate in words:

4.03.c no. 2 1 142 2,284

Rate in words:

4.05.a.1 rmt 114 1 625 185,250

Rate in words:

Supply and fixing of stainless steel mosquito proof jali with required fittings for over flow pipe of over head tank as per the requirement and drawings etc complete to the satisfaction of EIC

Providing and laying salt glazed stone-ware pipes of 230 mm diameter (to the level and slope) and jointing with stiff mixture of CM 1:1, at a depth from1.5 m to 3.0 m including testing of pipes and joints, etc. ( Necessary civil work like, excavation, refilling trenches, formwork, B.B.C.C, etc., shall be carried out, measured and paid in the relevant tender items of civil works) complete to the satisfaction of EIC

Providing and laying salt glazed stone-ware pipes of 150 mm diameter (to the level and slope) and jointing with stiff mixture of CM 1:1, at a depth upto 1.5 m including testing of pipes and joints, etc., ( Necessary civil work like, excavation, refilling trenches, formwork, B.B.C.C, etc., shall be carried out, measured and paid in the relevant tender items of civil works) complete to the satisfaction of EIC

Providing and laying salt glazed stone-ware pipes of 100 mm diameter (to level and slopes) and jointing with stiff mixture of CM 1:1, upto 1.5 m depth including testing of pipes and joints, etc., ( Necessary civil work like, excavation, refilling trenches, formwork, B.B.C.C, etc., shall be carried out, measured and paid in the relevant tender items of civil works) complete to the satisfaction of EIC

Providing and fixing a salt-glazed stoneware gully trap, class `A' of 150 mm dia inlet and 100 mm outlet with CI grating at the top, etc complete to the satisfaction of EIC (Necessary civil work like; excavation, CC 1:2:4, brick masonry, plastering etc., shall be carried out, measured and paid in the relevant tender items of civil works).

Providing and fixing a salt-glazed stoneware gully trap, class `A' of 230 mm dia inlet and 150 mm outlet with CI grating at the top,etc complete to the satisfaction of EIC (Necessary civil work like; excavation, CC 1:2:4, brick masonry, plastering etc., shall be carried out, measured and paid in the relevant tender items of civil works).

Providing and laying in trench reinforced concrete non-pressure IS class NP-2 pipes of 600 mm internal diameter at a depth upto 1.5 m on RCC cradle if specified (to the level and slope) and jointing with collars and butt-ends prepared for collar joints, including filling the joints with CM 1:1 and testing of joints, etc., The rates also excludes necessary excavation and filling of trenches etc complete to the satisfaction of EIC (RCC cradle and excavation, backfilling shall be measured and paid paid in the relevant tender items of civil works).

Page 21: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 21 of 53

Sr. No. Item Description Unit Quantity Rate Amount

4.05.a.2 rmt 0 1 625

Rate in words:

4.05.b.1 rmt 304 1 066 324,064

Rate in words:

4.05.b.2 rmt 0 1 048

Rate in words:

4.05.c.1 rmt 780 979 763,620

Rate in words:

4.05.c.2 rmt 900 856 770,400

Rate in words:

4.05.d.1 rmt 1,924 466 896,584

Rate in words:

Providing and laying in trench reinforced concrete non-pressure IS class NP-2 pipes of 600 mm internal diameter at a depth from 1.5 m to 3 m on RCC cradle if specified (to the level and slope) and jointing with collars and butt-ends prepared for collar joints, including filling the joints with CM 1:1 and testing of joints, etc., The rates also excludes necessary excavation and filling of trenches etc complete to the satisfaction of EIC (RCC cradle and excavation, backfilling shall be measured and paid paid in the relevant tender items of civil works).

Providing and laying in trench reinforced concrete non-pressure IS class NP-2 pipes of 450 mm internal diameter at a depth upto 1.5 m on RCC cradle if specified (to the level and slope) and jointing with collars and butt-ends prepared for collar joints, including filling the joints with CM 1:1 and testing of joints, etc., The rates also excludes necessary excavation and filling of trenches etc complete to the satisfaction of EIC (RCC cradle and excavation, backfilling shall be measured and paid paid in the relevant tender items of civil works).

Providing and laying in trench reinforced concrete non-pressure IS class NP-2 pipes of 450 mm internal diameter at a depth from 1.5 m to 3 m on RCC cradle if specified (to the level and slope) and jointing with collars and butt-ends prepared for collar joints, including filling the joints with CM 1:1 and testing of joints, etc., The rates also excludes necessary excavation and filling of trenches etc complete to the satisfaction of EIC (RCC cradle and excavation, backfilling shall be measured and paid paid in the relevant tender items of civil works).

Providing and laying in trench reinforced concrete non-pressure IS class NP-2 pipes of 300 mm internal diameter at a depth up to 1.5 m on RCC cradle if specified (to the level and slope) and jointing with collars and butt-ends prepared for collar joints, including filling the joints with CM 1:1 and testing of joints, etc., The rates also excludes necessary excavation and filling of trenches etc complete to the satisfaction of EIC (RCC cradle and excavation, backfilling shall be measured and paid paid in the relevant tender items of civil works).

Providing and laying in trench reinforced concrete non-pressure IS class NP-2 pipes of 300 mm internal diameter at a depth from 1.5 m to 3 m on RCC cradle if specified (to the level and slope) and jointing with collars and butt-ends prepared for collar joints, including filling the joints with CM 1:1 and testing of joints, etc., The rates also excludes necessary excavation and filling of trenches etc complete to the satisfaction of EIC (RCC cradle and excavation, backfilling shall be measured and paid paid in the relevant tender items of civil works).

Providing and laying in trench reinforced concrete non-pressure IS class NP-2 pipes of 230 mm internal diameter at a depth up to 1.5 m on RCC cradle if specified (to the level and slope) and jointing with collars and butt-ends prepared for collar joints, including filling the joints with CM 1:1 and testing of joints, etc., The rates also excludes necessary excavation and filling of trenches etc complete to the satisfaction of EIC (RCC cradle and excavation, backfilling shall be measured and paid paid in the relevant tender items of civil works).

Page 22: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 22 of 53

Sr. No. Item Description Unit Quantity Rate Amount

4.05.d.2 rmt 968 454 439,472

Rate in words:

4.05.e.1 rmt 1,769 268 474,092

Rate in words:

4.06.b.1 kg 38,504 129 4,967,016

Rate in words:

4.09 no. 1,521 245 372,645

Rate in words:

Sum Carried over to Summary page 9,400,925

SECTION - 5.0

5.01.a Job 58 164,674 9,551,092

Rate in words:

Rate in words:

5.01.b Job 54 119,646 6,460,884

Rate in words:

Providing and laying in trench reinforced concrete non-pressure IS class NP-2 pipes of 230 mm internal diameter at a depth from 1.5 m to 3 m on RCC cradle if specified (to the level and slope) and jointing with collars and butt-ends prepared for collar joints, including filling the joints with CM 1:1 and testing of joints, etc., The rates also excludes necessary excavation and filling of trenches etc complete to the satisfaction of EIC (RCC cradle and excavation, backfilling shall be measured and paid paid in the relevant tender items of civil works).

Providing and laying in trench reinforced concrete non-pressure IS class NP-2 pipes of 150 mm internal diameter up to 1.5 m depth on RCC cradle if specified (to the level and slope) and jointing with collars and butt-ends prepared for collar joints; including filling the joints with CM 1:1 and testing them etc., The rates also excludes necessary excavation and filling of trenches etc complete to the satisfaction of EIC (RCC cradle and excavation, backfilling shall be measured and paid paid in the relevant tender items of civil works).

Providing and fixing a cast iron grating frame and cover of specified clear size, shape and weight of NECO make including carting from store to site of work, fixing in CC and finishing with 3 coats of anti-corrosive paint etc complete to the satisfaction of EIC.

Providing and fixing, CI steps in manhole, water tank, septic tank, etc., of size 385 mm x 150 mm x 25 mm and painting with 3 coats of anti-corrosive paint, etc complete to the satisfaction of EIC (NECO make)

Solar System : (300 Lts / day) Consisting following - Make : Sola Hart made in Australia Model No. 302J

Supplying, storing, handling, erecting, testing and commissioning of Solar water heating system complete with Collectors, Tank, Pressure and temperature relief valve as mentioned bellow.Each system is required to be fitted with Aluminum stand which should be design to withstand max wind velocity of 140 km/hr. System should be pressured indirect heating system and including inbuilt appropriate electrical backup .

Tank specification - Each unit consist of 300 ltrs storage tank with compress puf insulation and ceramic lining from inside. Tank should be fitted with sacrifical anode and soft flow stratifier for batte drain down capacity. Pressure withstand capacity of each tank should be 15Kg / cm2 and test pressure at 25 Kg/cm2

Collector specification - Each unit consist of 35 Riser an pressure withstand capacity of collector is min 10 Kg/cm2. It should be capable of handling indirect heating fluid.

Hot water Circulating Pump - Make : Grundfos model No. UPS 15-14 BUT 80 with inbuilt timer and thermostat system

Solar System : (180 Lts / day) Consisting following - Make : Sola Hart made in Australia Model No. 181J

Page 23: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 23 of 53

Sr. No. Item Description Unit Quantity Rate Amount

5.02.a

no 13 50,211 652,743

Rate in words:

no 52 36,847 1,916,044

Rate in words: 0

5.03 Job 1 562,068 562,068

Rate in words:

- Type : Downflow 0

- Output/Reg.Base on 350PPM : 300 M3/Regeneration 0

- Max. Flow Rate Lts / Hr. : 40 M3 / Hr. 0

- Salt Required / Regeneration : 270 Kg 0

- Max. Working Pressure : 2 - 2.5 Kg / CM2 0

- Treated water hardness : Less than 50-100 PPM as CaCo3 0

- Duration of Regeneration : 75 Minutes 0

Softener Vessel : MS / FRP 0

Resin : Cation Resins / Ion Exchange 0

Resin : Quantities 1800 - 2000 Lts 0

0

5.04

1) 50 Lts / Hour Capacity Job 65 56,831 3,694,015

Rate in words: 0

- Skid : SS Frame 0

- Pre Filter : 20" x 2.5" x 20 Micron PP Filter USA 0

- Carbon Filter : 20" Activated carbon block filter 0

- Booster pump : 235 PSI pressure (2 Nos) 0

- Membrane : 75 GPD (5 Nos) 0

- Post carbon filter : 2 Nos. 0

- Water rejection : Less then 50 % 0

- Auto flushing : Solenoid valve 0

- Automatic ON / OFF : Floating switch 0

- Pressure gauge meter : Approved quality 0

- Indicator : Power, Working, Low pressure, Auto flushing, Tank Full 0

- TDS Rejection : 90 to 95 % 0

2) 10 Lts / Hour Capacity Job 70 16,862 1,180,340

Rate in words: 0

Supplying, storing, handling, erecting, testing and commissioning of Solar water heating system complete with Collectors, Tank, Pressure and temperature relief valve as mentioned bellow.Each system is required to be fitted with Aluminum stand which should be design to withstand max wind velocity of 140 km/hr. System should be pressured indirect heating system and including inbuilt appropriate electrical backup .

Tank specification - Each unit consist of 180 ltrs storage tank with compress puf insulation and ceramic lining from inside. Tank should be fitted with sacrifical anode and soft flow stratifier for batte drain down capacity. Pressure withstand capacity of each tank should be 15Kg / cm2 and test pressure at 25 Kg/cm2

Collector specification - Each unit consist of 35 Riser an pressure withstand capacity of collector is min 10 Kg/cm2. It should be capable of handling indirect heating fluid.

Hot water Circulating Pump - Make : Grundfos model No. UPS 15-14 BUT 80 with inbuilt timer and thermostat system

Supply, testing and commissioning of following size water cooler with all required hardwares etc. complete as per the direction of EIC - Blue Star make

1) 120 Lts. Storage, 80 Lts / hour cooling capacity Model No. SDIx8120

2) 80 Lts. Storage, 40 Lts / hour cooling capacity Model No. SDIx480

Supply, erection, testing and commissioning of water Softening plant of consisting followings, The supplier / Contractor shall submit the Technical Data Sheet along with the bid. Makes : Jay Pumps / Ion Exchange or Approved equivalent

Raw water pump : Grundfos / Kirlosker make including 1 stand by pump duly fully automatic valve / operating

Supply, erection, testing and commissioning of R.O. Water plant of followings size : The supplier / Contractor shall submit the Technical Data Sheet along with the bid. Makes : Jay Pumps / Ion Exchange or Approved equivalent

Page 24: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 24 of 53

Sr. No. Item Description Unit Quantity Rate Amount

- Skid : SS Frame 0

- Pre Filter : 10" x 5" x 20 Micron PP Filter USA 0

- Carbon Filter : 10" Activated carbon block filter 0

- Booster pump : 80 PSI pressure (2 Nos) 0

- Membrane : 75 GPD 0

- Post carbon filter : 0

- Water rejection : Less then 60 % 0

- Auto flushing : Solenoid valve 0

- Automatic ON / OFF : Floating switch 0

- Pressure gauge meter : Approved quality 0

- Indicator : Power, Working, Low pressure, Auto flushing, Tank Full 0

5.05 0

Set 2 94,447 188,894

Rate in words: 0

Set 2 143,067 286,134

Rate in words:

5.06 JOB 1 3,563,007 3,563,007

Rate in words:

Sum Carried over to Summary page 28,055,221

Supply, erection, testing and commissioning of following pump sets complete as per the direction of EIC.

1) Water supply Pump : 850 LPM @ 25 M head, with required electrical cords from starter panel to pump including L & T make Motor starter panel of appropriate capacity including liquid level controller with necessary sensor with required wiring etc complete to the satisfaction of EIC : Pump model No NB 40 - 160 / 172 of Grundfos

2) Drainage Pump : 5 Cu.M / Hour @ 20 M head, with required electrical cords from starter panel to pump including Control panel of approved make. Motor protection starter panel of appropriate capacity including inbuilt automatic pump operating system with necessary sensor with required wiring etc complete to the satisfaction of EIC : Pump model No SEG 40.15. with Grinder system

Supply, erection, testing and commissioning of 300 Cu.M per Day RBC based compact sewage treatment plant to match following parameters. The system produces very little sludge– and that too in a completely mineralized form convertible into garden compos. Including required civil foundations / base pad, plumbing works, necessary electrification with required strters/ panel for fully atomization. Refer the details specification in the tender. (Excavation, PCC, RCC pump / Machine foundations, bk. work, plaster, backfilling shall be measured and paid for separately in relevant civil items).

It should match local pollution board land discharge norms. Also, the contractor shall submit P & I diagram and tentative layout showing overall size for space requirement alongwith offer. The overall hight of plant shall not be exceed 3 mts from finished ground level and with minimum area occupancy. Make: Thermex / Naik Environmental Engineers Pvt. Ltd. The supplier / Contractor shall submit the Technical Data Sheet along with the bid.

Page 25: SPCL Offer 9(New)_03.12.09

Tender DocumentsAga Khan Academy, Hyderabad

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 25 of 53

SUMMARY OF ELECTRICAL WORKS

Sr. No. Description Total Amount (Indian Rupees)

2 HT Breaker 1,710,125

3 Transformer 5,775,699

4 Busduct 1,345,635

5 Substation Equipment & Substation Auxiliary 617,098

6 MV Switchgear & Power Panels 11,818,870

7 DG set 7,011,437

8 Distribution Board 3,898,710

9 Cable Trench 4,061,250

10 Cables 32,458,615

11 Cable Termination 645,261

12 Cable Tray 1,836,900

14 Internal Wiring 14,318,905

15 Light Fixtures & Fans 38,411,520

16 Earthing 2,726,223

17 Telephone And Data Distribution 5,665,099

18 Miscellaneous 213,793

19 External Lighting 31,749,744

20 Television Distribution 638,067

Total Amount: 164,902,951

Amount in Words:

Signature of Authorised Signatory Stamp of the Bidder

Page 26: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 26 of 53

BILL OF QUANTITIES - ELECTRICAL WORKS

Sr. No. Item Description Unit Quantity Rate Amount

2.0 HT breaker

2.1 No. 1 1,710,125 1,710,125

Sub Total 2.0..... 1,710,125

3.0 Transformer

3.1 No. 3 1,925,233 5,775,699

Sub Total 3.0..... 5,775,699

4.0 Busduct

4.1 45 29,903 1,345,635

Sub Total 4.0..... 1,345,635

5.0 Substation Equipment & Substation Auxiliary

5.1 Rmt. 60 1,225 73,500

5.2 No. 8 12,864 102,912

5.3 No. 3 6,344 19,032

5.4 No. 3 6,779 20,337

5.5 No. 10 1,166 11,660

5.6 No. 25 750 18,750

5.7 No. 5 1,419 7,095

5.8 No. 12 121 1,452

5.9 No. 6 150 900

5.10 No. 8 415 3,320

5.11 No. 2 506 1,012

5.12 Supplying Standard First aid box with all the Standard contents. No. 2 1,085 2,170

5.13 No. 8 306 2,448

5.14 No. 2 1,265 2,530

5.15 No. 8 135 1,080

Supplying, Testing & Commissioning of HT VCB panel consisting of 1 no. of 400A HT VCB as incoming and 3 nos of 400A HT VCB as outgoing. The panel should have tinned copper busbars and extensible type for future requirements. The Panel should be complete with metering and protection as per specification.

Supplying, Testing, Commissioning & unloading at site, shifting to the erection site assembling, leveling, grouting, installing and commissioning of Dry Type cast resin Transformer with on load tape chagner and RTCC panel of 750 KVA

Supplying, assembling, grouting in slab with hanging rods/ strips, water proof, dust proof, vermin proof busduct to be fabricated out of 14 gauge sheet. The busduct should be processed through 7 tank process. The busduct should be powder coated. All joints should be fitted with neoprene gasket. The busduct should confirm to IP 43 protection.The capacity of the busbar should be four pole 1200A amp and should be of tinned EC grade Cu material, with necessary flexible bends. Necessary certificate shall be required at the time of supply.The capacity of neutral bus should be equal to phase bus. (INDOOR DUTY)

SITC of 11 KV, 3 core Al. 240 sqmm H.T. XLPE armoured unearth cable

SITC of H.T. cable indoor type end connection for 11 KV XLPE, 240 sq mm x 3 core cable

Supplying & Erecting conventional type Carbon Dioxide fire extinguishers of ISI approved of 3.2 kgs

Supplying & Erecting conventional tyep Carbon Dioxide fire extinguishers of ISI approved of 5.0 kgs

Suppplying & Erecting automatic emergency light with maintenance free battery for 20 watts tube. With exide make battery

Supplying & Erecting Rubber mat 1.1 KV grade ISI marked 1000 x 2000 x 6 mm size.

Supplying & Erecting Rubber mat 11 KV grade ISI marked 1000 x 2000 x 12 mm size.

Providing and erecting danger notice board for medium voltage installation to be erected as per I.S. The board should be 150 x 150 mm.

Providing and erecting danger notice board for high voltage installation to be erected as per I.S.

Providing printed instruction chart both in English & REGIONAL LANGUAGE & duly framed out on glass for treatment of person suffering from Electric shock.

Providing pair of rubber hand gloves suitable for working on 11 KV/22 KV supply.

Supplying GI bucket round bottom duly painted 13 Ltrs. capacity & filled with dry sand & kept on stand provided on stand or wall hook.

Supplying & Erecting 1.5 mtr. (5') x 0.9 mtr. (3.1') x 0.6 mtr. (2.1') Floor mounted stand (For keeping 4 Nos.of buckets) made of 30 x 30 x 4 mm. angle iron welded with 4 hooks and duly painted with one coat of red lead & two coats of Approved enameled silver paints.

Wall hooks of 22 to 25 cms. projection for keeping fire buckets made out of 15 mm. dia M.S. rod grouted in wall to a depth of minimum 15 cms.

Page 27: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 27 of 53

Sr. No. Item Description Unit Quantity Rate Amount

5.16 LS 1 348,900 348,900

Sub Total 5.0..... 617,098

6.0 MV Switchgear & Power Panels

6.1

6.1.1 Main Panel of Academy building No. 1 477,191 477,191

as per attached Single Line Diagram

6.1.2 Lighting Panel of Academy building No. 3 33,687 101,061

as per attached Single Line Diagram

6.1.3 Computer Panel of Academy Building No. 1 33,754 33,754

as per attached Single Line Diagram

6.1.4 Main AC Panel of Academy Building No. 1 245,704 245,704

as per attached Single Line Diagram

6.1.5 Emergency Panel C No. 1 53,368 53,368

as per attached Single Line Diagram

6.1.6 Main Panel of SR-7-8 No. 4 56,152 224,608

as per attached Single Line Diagram

6.1.7 Emergency Panel of SR 7-8 No. 4 17,173 68,692

as per attached Single Line Diagram

6.1.8 Solar Panel of SR 7-8 No. 4 10,103 40,412

as per attached Single Line Diagram

6.1.9 Main Panel of SR 9-10 No. 2 73,946 147,892

as per attached Single Line Diagram

6.1.10 Emergency Panel of SR 9-10 No. 2 19,594 39,188

as per attached Single Line Diagram

6.1.11 Solar Panel of SR 9-10 No. 2 15,357 30,714

as per attached Single Line Diagram

6.1.12 Main Panel of SR 11-12 No. 2 153,474 306,948

as per attached Single Line Diagram

6.1.13 Emergency Panel of SR 11-12 No. 2 20,441 40,882

as per attached Single Line Diagram

6.1.14 Solar Panel of SR 11-12 No. 2 15,357 30,714

as per attached Single Line Diagram

6.1.15 Main Panel of Principal's Bunglow No. 1 32,547 32,547

as per attached Single Line Diagram

6.1.16 Emergency Panel of Pricipal's bunglow No. 1 7,870 7,870

as per attached Single Line Diagram

6.1.17 Solar Panel of Pricipal's bunglow No. 1 10,044 10,044

as per attached Single Line Diagram

6.1.18 Main Panel of Nursery No. 1 40,415 40,415

as per attached Single Line Diagram

6.1.19 Emergency Panel of Nursery No. 1 8,328 8,328

as per attached Single Line Diagram

6.1.20 Main Panel of Junior Academy No. 1 175,264 175,264

as per attached Single Line Diagram

6.1.21 Emergency Panel of Junior Academy No. 1 22,696 22,696

as per attached Single Line Diagram

6.1.22 Main Computer Panel of Junior Acdemy No. 1 10,648 10,648

as per attached Single Line Diagram

6.1.23 Sub LT Panel of Junior Academy ( Library) No. 1 96,220 96,220

as per attached Single Line Diagram

6.1.24 Sub LT Panel of Junior Academy ( Laboratry) No. 1 54,578 54,578

as per attached Single Line Diagram

6.1.25 Main Panel of Guest House No. 1 75,278 75,278

as per attached Single Line Diagram

6.1.26 Emergency Panel of Guest House No. 1 9,512 9,512

as per attached Single Line Diagram

6.1.27 Solar Panel of Guest House No. 1 13,523 13,523

as per attached Single Line Diagram

Preparing necessary drawing submitting to authorities, getting their approval / senction and final certificate to energize the sub-station equipment’s.Filling the necessary application to supply co. following up and getting the supply filling the necessary test report to the supply co. inclusive. All official / statutory fees shall be paid by clients.

Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning of L.T. panel board, fabricated from CRCA sheet & folded channel totally enclosed cubical type compartmentalized as per drawings.

Page 28: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 28 of 53

Sr. No. Item Description Unit Quantity Rate Amount

6.1.28 Main Panel of Student Longue No. 1 40,899 40,899

as per attached Single Line Diagram

6.1.29 Main Panel of Senior Academy No. 1 214,540 214,540

as per attached Single Line Diagram

6.1.30 Lighitng Panel of Senior Academy No. 1 78,305 78,305

as per attached Single Line Diagram

6.1.31 Computer Panel of Academy Building No. 1 16,945 16,945

as per attached Single Line Diagram

6.1.32 Emergency Panel of Senior Academy No. 1 11,967 11,967

as per attached Single Line Diagram

6.1.33 Sub LT Panel of senior Academy for lab No. 1 101,909 101,909

as per attached Single Line Diagram

6.1.34 Main Panel of Athletic centre No. 1 170,421 170,421

as per attached Single Line Diagram

6.1.35 Main Panel of Athletic centre- squash Building No. 1 43,321 43,321

as per attached Single Line Diagram

6.1.36 AC Panel of Athletic centre No. 1 82,057 82,057

as per attached Single Line Diagram

6.1.37 Emergency Panel of Athletic centre No. 1 11,747 11,747

as per attached Single Line Diagram

6.1.38 Main Panel of Health & Wellness centre No. 1 38,115 38,115

as per attached Single Line Diagram

6.1.39 Main Panel of Seminar block of Senoir Academy No. 1 64,020 64,020

as per attached Single Line Diagram

6.1.40 Emergency Panel of Seminar Block of Senior Academy No. 1 10,053 10,053

as per attached Single Line Diagram

6.1.41 Main Panel of Mech. Workshop No. 42,831

as per attached Single Line Diagram

6.1.42 Main Panel of common( Dinning) No. 1 226,645 226,645

as per attached Single Line Diagram

6.1.43 Emergency Panel of common( Dinning) No. 1 55,910 55,910

as per attached Single Line Diagram

6.1.44 AC Panel of common( Dinning) No. 1 143,430 143,430

as per attached Single Line Diagram

6.1.45 Main LT Panel for Transformer :1 No. 1 1,115,851 1,115,851

as per attached Single Line Diagram

6.1.46 Main LT Panel for Transformer :2 No. 1 1,406,669 1,406,669

as per attached Single Line Diagram

6.1.47 Main LT Panel for Transformer :3 No. 1 1,383,641 1,383,641

as per attached Single Line Diagram

6.1.48 No. 2 280,852 561,704

as per attached Single Line Diagram

6.1.49 Main Emergency Panel No. 1 891,170 891,170

as per attached Single Line Diagram

6.1.50 Emergency Panel A No. 1 39,820 39,820

as per attached Single Line Diagram

6.1.51 Emergency Panel B No. 1 39,820 39,820

as per attached Single Line Diagram

6.1.52 Emergency Panel D No. 1 104,209 104,209

as per attached Single Line Diagram

6.1.53 Emergency Panel E No. 1 36,055 36,055

as per attached Single Line Diagram

6.1.54 Faculty Residence Cluster 1 No. 1 254,537 254,537

as per attached Single Line Diagram

6.1.55 Faculty Residence Cluster 2 No. 1 254,537 254,537

as per attached Single Line Diagram

6.1.56 Faculty Residence Cluster 3 No. 1 193,960 193,960

as per attached Single Line Diagram

6.1.57 Faculty Residence Cluster 4 No. 1 286,549 286,549

as per attached Single Line Diagram

6.1.58 Plumbing panel -1 No. 1 46,226 46,226

as per attached Single Line Diagram

6.1.59 Plumbing panel -2 No. 1 46,226 46,226

as per attached Single Line Diagram

6.1.60 300 KVAR APFCR Panel No. 3 483,187 1,449,561

1200A FP ACB Bus coupler with electrical and mechanical interlock with encloser having same size same as main LT panels.

Page 29: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 29 of 53

Sr. No. Item Description Unit Quantity Rate Amount

as per attached Single Line Diagram

Sub Total 6.0..… 11,818,870

7.0 DG set

7.1 No. 1 7,011,437 7,011,437

Sub Total 7.0..… 7,011,437

8.0 Distribution Board

8.1 TPN Distribution Board :

8.1.1 No. 25 5,388 134,700

8.1.2 No. 80 4,422 353,760

8.1.3 No. 107 3,275 350,425

8.1.4 No. 27 2,379 64,233

8.2 SPN Distribution Board

8.2.1 No. 1 1,713 1,713

8.2.2 No. 3 1,413 4,239

8.2.3 No. 89 850 75,650

8.2.4 No. 73 1,517 110,741

8.2.5 No. 171 1,320 225,720

8.3 VTPN Distribution Board

8.3.1 No. 12,578

8.3.2 No. 2 9,259 18,518

Supplying, installation, testing and commissioning of DG set of 725/750 KVA with approximate 890 BHP engine & suitable alternator complete with all necessary fuel piping,Aluminium cladding, exhaust piping, control panel, AMF Panel, silencer & its piping, Acoustic silencer, Alternator cable termination box suitable for Aluminium cables,initial battery charging,base frame, battery and charger complete in all respect. Scope also includes preparing necessary drawing submitting to authorities, getting their approval / sanction and final certificate including NOC from pollution board(if required) to energize the D G Set .

Supplying, assembling, grouting, levelling, installation, Connecting & testing D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement.

Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 12 SPMCB as outgoing per phase (i.e. 16 way TPN D.B.) eqequivalent to MDS cat no 607719 with 16 way PPI kit cat no.607894

Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 8 SPMCB as outgoing per phase (i.e. 12 way TPN D.B.) eqequivalent to MDS cat no 607718 with 12 way PPI kit cat no.607893

Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 4 SPMCB as outgoing per phase (i.e. 8 way TPN D.B.) eqequivalent to MDS cat no 607717 with 8 way PPI kit cat no.607892

Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for 3 no. FPMCB as outgoing(i.e. 4 way TPN D.B.) equivalent to MDS cat no 607715 with necessary busbar link)

Supplying, erecting, testing and commissioning of SPN D.B. with space for DPELMCB as incoming and 12 SPMCB as outgoing per phase (i.e. 16 way SPN D.B.) equivalent to MDS cat no. 607713

Supplying, erecting, testing and commissioning of SPN D.B. with space for DPELMCB as incoming and 8 SPMCB as outgoing per phase (i.e. 12 way SPN D.B.) equivalent to MDS cat no. 607712

Supplying, erecting, testing and commissioning of SPN D.B. with space for DPELMCB as incoming and 4 SPMCB as outgoing per phase (i.e. 8 way D.B.) equivalent to MDS cat no. 607711

Supplying, erecting, testing and commissioning of SPN D.B. suitable for outdoor mounting IP 65 with space for DPMCB as incoming and 4 SPMCB as outgoing (i.e. 6 way SPN D.B.) equivalent to Hensel make cat no. KV 7106

Supplying, erecting, testing and commissioning of SPN D.B. suitable for outdoor mounting IP 65 with space for DPMCB as incoming and 2 SPMCB as outgoing (i.e. 4 way SPN D.B.) equivalent to Hensel make cat no. KV 7104

Supplying,erecting, testing and commissioning of only VTPN D.B. having suitable space for 250 A FP MCCB as incomer and 12 TP MCBs as outgoing equivalent to MDS cat no 607822

Supplying,erecting, testing and commissioning of only VTPN D.B. having suitable space 125 A FP MCCB as incomer and 12 TP MCBs as outgoing equivalent to MDS cat no 607792

Page 30: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 30 of 53

Sr. No. Item Description Unit Quantity Rate Amount

8.3.3 No. 2 7,278 14,556

8.3.4 No. 1 5,771 5,771

8.3.5 No. 4 6,355 25,420

8.3.6 No. 5,252

8.4 MCB 's and its Accessories

8.4.1 6 to 32 A SP MCB No. 4,863 134 651,642

8.4.2 6 to 32 A DP MCB No. 4 374 1,496

8.4.3 40 A DP Isolator No. 201 250 50,250

8.4.4 40/63 A FP Isolator No. 61 566 34,526

8.4.5 6 A DP ELMCB(ELCB+MCB) (30mA) No. 2 1,522 3,044

8.4.6 16 A DP ELMCB(ELCB+MCB) (30mA) No. 46 1,487 68,402

8.4.7 32 A DP ELMCB(ELCB+MCB) (30mA) No. 335 1,615 541,025

8.4.8 32 A DP ELMCB(ELCB+MCB) (100mA) No. 94 1,798 169,012

8.4.9 40 A DP ELMCB(ELCB+MCB) (30mA) No. 36 1,888 67,968

8.4.10 40 A DP ELMCB(ELCB+MCB) (100mA) No. 87 2,010 174,870

8.4.11 63 A DP ELMCB(ELCB+MCB) (30mA) No. 21 2,190 45,990

8.4.12 63 A DP ELMCB(ELCB+MCB) (100mA) No. 114 2,305 262,770

8.4.13 32 A TP MCB No. 36 595 21,420

8.4.14 40 A TP MCB No. 4 900 3,600

8.4.15 63 A TP MCB No. 4 900 3,600

8.4.16 32 A FP MCB No. 173 786 135,978

8.4.17 40 A FP MCB No. 47 1,148 53,956

8.4.18 63 A FP MCB No. 85 1,148 97,580

8.4.19 Sheet steel metal enclouser for SP MCB cat no.607881 No. 244

8.4.20 Sheet steel metal enclouser for DP MCB cat no.607882 No. 13 316 4,108

8.4.21 Sheet steel metal enclouser for FP MCB cat no.607884 No. 41 362 14,842

8.4.22 Blank Plates No. 450 14 6,300

8.5 MCCBs:

8.5.1 100 A FP MCCB not less than 10 KA No. 4 4,568 18,272

8.5.2 125 A FP MCCB not less than 10 KA No. 1 4,874 4,874

8.5.3 160 A FP MCCB not less than 16 KA No. 1 14,856 14,856

8.5.4 250 A FP MCCB not less than 25 KA No. 1 14,790 14,790

8.6 Caution Board :

8.6.1 No. 243 151 36,693

8.6.2 No. 100 114 11,400

Sub Total 8.0..... 3,898,710

9 Cable Trench

9.1 RMt 4,275

9.2 RMt 14,250 285 4,061,250

Sub Total 9.0..... 4,061,250

10 Cables

Supplying,erecting, testing and commissioning of only VTPN D.B. having suitable space for 125 A FP MCCB as incomer and 8 TP MCBs as outgoing equivalent to MDS cat no 607791

Supplying,erecting, testing and commissioning of only VTPN D.B. having suitable space for 125 A FP MCCB as incomer and 4 TP MCBs as outgoing equivalent to MDS cat no 607790

Supplying,erecting, testing and commissioning of only VTPN D.B. having suitable space for 63 A FP MCB as incomer and 8 TP MCBs as outgoing equivalent to MDS cat no 607751

Supplying,erecting, testing and commissioning of only VTPN D.B. having suitable space for 32 A FP MCB as incomer and 4 TP MCBs as outgoing equivalent to MDS cat no 607750

Supplying, Assembling, levelling, connecting & testing following MCB / ELMCB / Isolators etc in boards as specified in 8.1, 8.2.

Supplying, Assembling, levelling, connecting & testing following MCCB etc in boards as specified in 8.1, 8.2.

Caution boards of size 150 x 150 mm. to be supplied & fixed on the D.B.

Caution boards of size 100 x 100 mm. to be supplied & fixed on the D.B.

Excavation and back filling of cable trenches required for laying the cables directly buried in the ground. This includes supplying and providing cable markers at an interval of 10 meters. The depth shall be app. 0.7mtr and the width shall be as per requirement.

Supplying and spreading fine sand for a thickness of 100 mm. and providing and laying bricks for protection on cable on all the three sides.

Page 31: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 31 of 53

Sr. No. Item Description Unit Quantity Rate Amount

Aluminium Cables

10.1 400 Sq.mm x 3.5C Al. Cable RMt 17,973 851 15,295,023

10.2 300 Sq.mm x 3.5C Al. Cable RMt 8,715 685 5,969,775

10.3 240 Sq.mm x 3.5C Al. Cable RMt 5,840 565 3,299,600

10.4 185 Sq.mm x 3.5C Al. Cable RMt 2,953 451 1,331,803

10.5 150 Sq.mm x 3.5C Al. Cable RMt 100 406 40,600

10.6 120 Sq.mm x 3.5C Al. Cable RMt 793 329 260,897

10.7 95 Sq.mm x 3.5C Al. Cable RMt 1,636 272 444,992

10.8 70 Sq.mm x 3.5C Al. Cable RMt 815 215 175,225

10.9 50 Sq.mm x 3.5C Al. Cable RMt 1,334 170 226,780

10.10 35 Sq.mm x 3.5C Al. Cable RMt 1,150 131 150,650

10.11 25 Sq.mm x 4C Al. Cable RMt 165 135 22,275

Copper Cables

10.12 16 Sq.mm x 4C Cu. Cable RMt 930 304 282,720

10.13 10 Sq.mm x 4C Cu. Cable RMt 8,975 212 1,902,700

10.14 6 Sq.mm x 4c Cu. Cable RMt 8,735 148 1,292,780

10.15 4 Sq.mm x 4c Cu. Cable RMt 7,645 113 863,885

10.16 2.5 Sq.mm x 4c Cu. Cable RMt 2,374 80 189,920

10.17 6 Sq.mm x 3c Cu. Cable RMt 100 129 12,900

10.18 4 Sq.mm x 3c Cu. Cable RMt 5,280 91 480,480

10.19 2.5 Sq.mm x 3c Cu. Cable RMt 2,085 66 137,610

10.20 1.5 Sq.mm x 3c Cu. Cable RMt 1,560 50 78,000

Sub Total 10.0..... 32,458,615

11 Cable Termination

Aluminium Cables

11.1 400 Sq.mm x 3.5C Al. Cable No. 54 2,585 139,590

11.2 300 Sq.mm x 3.5C Al. Cable No. 48 2,033 97,584

11.3 240 Sq.mm x 3.5C Al. Cable No. 28 1,745 48,860

11.4 185 Sq.mm x 3.5C Al. Cable No. 16 1,351 21,616

11.5 150 Sq.mm x 3.5C Al. Cable No. 4 1,340 5,360

11.6 120 Sq.mm x 3.5C Al. Cable No. 6 1,304 7,824

11.7 95 Sq.mm x 3.5C Al. Cable No. 8 1,112 8,896

11.8 70 Sq.mm x 3.5C Al. Cable No. 8 878 7,024

11.9 50 Sq.mm x 3.5C Al. Cable No. 22 234 5,148

11.10 35 Sq.mm x 3.5C Al. Cable No. 16 200 3,200

11.11 25 Sq.mm x 4C Al. Cable No. 16 171 2,736

Copper Cables

11.12 16 Sq.mm x 4c Cu. Cable No. 18 183 3,294

11.13 10 Sq.mm x 4c Cu. Cable No. 391 141 55,131

11.14 6 Sq.mm x 4c Cu. Cable No. 600 127 76,200

11.15 4 sq.mm x 4 c Cu. No. 511 120 61,320

11.16 2.5 sq.mm x 4 c Cu. No. 168 92 15,456

11.17 6 Sq.mm x 3c Cu. Cable No. 6 115 690

11.18 4 Sq.mm x 3c Cu. Cable No. 542 110 59,620

11.19 2.5 Sq.mm x 3c Cu. Cable No. 176 77 13,552

11.20 1.5 Sq.mm x 3c Cu. Cable No. 160 76 12,160

Sub Total 11.0..... 645,261

12 Cable Tray

12.1

12.1.1 150 x 50 made out of 2 mm thick RMt 970 317 307,490

12.1.2 300 x 100 made out of 2 mm thick RMt 1,250 480 600,000

Supply, testing and Laying XLPE steel/GI wire/flat armoured cable of 1100 V grade of Aluminum / Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support.

Supplying & fixing single compression type Brass glands (single compression for indoor application and double compression for outdoor applications) & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes:

Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :

Page 32: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 32 of 53

Sr. No. Item Description Unit Quantity Rate Amount

12.1.3 450 x 100 made out of 2 mm thick RMt 345 531 183,195

12.1.4 600 x 100 made out of 2 mm thick RMt 270 594 160,380

12.2

12.2.1 150 x 50 made out of 2 mm thick RMt 145 371 53,795

12.2.2 300 x 100 made out of 2 mm thick RMt 390 654 255,060

12.2.3 450 x 100 made out of 2 mm thick RMt 100 851 85,100

12.2.4 600 x 100 made out of 2 mm thick RMt 180 1,066 191,880

Sub Total 12.0..... 1,836,900

14 Internal Wiring

14.1

For Light Points /fan point/ wall fan / 6A 3 Pin Plug

- DB to SB - 2.5sqmm for Phase & Neutral & 1.5 sqmm for Earth

- SB to Point - 1.5 sqmm for Phase & Neutral & Earth

For 6A plug point

For 6/10/16A general purpose plug point

- 2.5 sqmm for Phase, Neutral & 1.5 sq. mm Earth

For 16A plug point for A/C and Geyser

- 4 sqmm for Phase, Neutral & 2.5 sq. mm Earth

For 20/32A plug point

- 6 sqmm for Phases, Neutral & 4 sq. mm Earth

14.1.1 One light point controlled by one single way 6 A switch. No. 4,189 944 3,954,416

14.1.2 Loop light point to be controlled from same switch. No. 2,835 249 705,915

14.1.3 One light point controlled by two, two way 6 A switch No. 509 1,093 556,337

14.1.4 No. 1,092 952 1,039,584

14.1.5 No. 1,826 221 403,546

14.1.6 6 A x 5 pin 250 Volt switched socket outlet point at convenient location. No. 577 597 344,469

14.1.7 No. 690 1,085 748,650

14.1.8 6/16A x 250 Volt switched socket outlet point for A.C./Geyser. No. 70 1,817 127,190

14.1.9 -Do- as above but switch and socket at different location. No. 6 2,061 12,366

14.1.10 No. 305 926 282,430

14.1.11 10A x 250V Metal clad socket outlet point with 10 Amp. SPMCB. No. 12 925 11,100

Supply & Installation of hot dip GI Perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware :

Wiring of points to be done in open/concealed manner in 25 mm dia medium guage Rigid PVC FRLS pipe. Wiring shall be done with FRLS type copper flexible wire of 650V/1100V. Separate pipe should be taken for circuit mains. Nos of ciruit of the same phases may be taken in same conduit (maximum 2 ckts).The circuit shall be laid in 25/40 mm dia medium guage rigid PVC FRLS pipe.The point rate shall include all the necessary piping and wiring from sub panel / Distribution board to switch board & switch board to the batten holder / angle holder / connector / ceiling rose all inclusive except sub panel / Dist board.

The wiring shall be done as per relevant prevailing standard. The looping of the wiring should be done in the switch boxes or light and fan point outlet boxes to avoid the junction boxes. The junction boxes and switch boxes for the ceiling light point, fan point etc shall be minimum 60/75 deep. All the necessary jarry in brick plastered walls should be done with machine cutter only , also jarry should be filled with cement, sand and wire mesh as required, the material cost for rough finish shall be included in point rate.Whenever pipes are required to be laid in flooring shall be of heavy guage.Wiring should be done as per distribtion details. Each circuit should have dedicated phase, neutral & earth wire. Wire sizes to be used as under

-  1.5 sqmm for Phase, Neutral & Earth

No zarry will be allowed in expose brick work. The conduit shall be provided when the walls are under construction. The pipes in slab shall be laid before the slab is casted.

One ceiling fan outlet point controlled by one 6 A switch and hum free electronic type step regulator.

One 6 A x 5 pin 250 Volt socket outlet point controlled by one 6 A switch located on switch board.

6/16 A x 250 V switch socket point on one switch box. (Approx two points in one circuits)

Exhaust fan outlet point with 6A 5 pin socket controlled by one 5 single way switch located at different location.

Page 33: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 33 of 53

Sr. No. Item Description Unit Quantity Rate Amount

14.1.13 20 A x 250 Volt metal clad socket outlet point with 20 Amp. SPMCB. No. 15 1,000 15,000

14.1.14 No. 12 3,555 42,660

14.1.15 No. 11 5,149 56,639

14.1.16 No. 3 6,088 18,264

14.1.17 No. 6 7,727 46,362

14.1.18 No. 90 1,053 94,770

14.1.19 Bell point controlled by Bell push switch with bell of approved make. No. 70 950 66,500

14.1.20 No. 795 1,013 805,335

14.2 MAINS :

14.2.1 Rmtr 1,057

14.2.2 Rmtr 2,070 545 1,128,150

14.2.3 Rmtr 1,185 399 472,815

14.2.4 Rmtr 4,226 254 1,073,404

14.2.5 Rmtr 990 227 224,730

14.2.6 Rmtr 8,420 133 1,119,860

14.2.7 Rmtr 1,152 114 131,328

32 A 5 pin x 415 Volt (3 Phase) Metal clad socket outlet point with 32 Amp. FPMCB.

16 A x 250 V plug & socket with interlocked switched socket, DP MCB and surface mounting box IP 66 with DIN rail for 2 module equivalent to legrand make Cat no.56661 but without cost of wiring and piping.

32 A x 250 V plug & socket with interlocked switched socket, DP MCB and surface mounting box IP 66 with DIN rail for 5 module equivalent to legrand make Cat no.56669 but without cost of wiring and piping.

32 A x 415 V plug & socket with interlocked switched socket, FP MCB and surface mounting box IP 66 with DIN rail for 5 module equivalent to legrand make Cat no.56674 but without cost of wiring and piping.

Buzzer point controlled by Bell push with modular type buzzer same make as switch

SITC computer power supply point with 2 nos of 6 amp 5 pin plugs with 1 no. of 16 Amp. Plug with 1 no 16 A Switch with indicator & wiring of computer point.

The mains is considered from the meter/sub panel to the individual distribution boards.

Supplying and Laying mains with 4 nos. of 25 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and 2 nos 10 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 50 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.

Supplying and Laying mains with 4 nos. of 16 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and 2 nos 6 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.

Supplying and Providing mains with 4 nos. of 10 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and 2 nos 4 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.

Supplying and Providing mains with 4 nos. of 6 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and 2 nos 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.

Supplying and Laying mains with 2 nos. of 10 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and 1 no 6.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories.

Supplying and Providing mains with 2 nos. of 6 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and 1 nos 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.

Supplying and Providing mains with 3 nos. of 4 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.

Page 34: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 34 of 53

Sr. No. Item Description Unit Quantity Rate Amount

14.2.8 Rmtr 99

14.2.9 Rmtr 70

14.3 Race way

14.3.1 Rmtr 485 813 394,305

14.3.2 Rmtr 75 480 36,000

14.3.3 Rmtr 55 4,318 237,490

14.3.4 Rmtr 270 627 169,290

Sub Total 14.0..... 14,318,905

15 Light Fixtures & Fans

15.1

15.1.1 Light Fixture Type A with basic rate as specified separately No. 3,862 3,693 14,262,366

15.1.2 Light Fixture Type B with basic rate as specified separately No. 3,672 5,528 20,298,816

15.1.3 No. 110 6,056 666,160

15.1.4 No. 67 8,225 551,075

15.2

15.2.1 No. 80 1,627 130,160

15.2.2 No. 961 1,528 1,468,408

15.2.3 No. 48 1,915 91,920

15.2.4 No. 598 105 62,790

15.3

15.3.1 No. 167 1,969 328,823

15.3.2 No. 83 2,207 183,181

15.3.3 No. 57 6,453 367,821

Sub Total 15.0..... 38,411,520

16 Earthing

16.1

16.1.1 600 x 600 x 6.15 mm cu.plate No. 8 18,165 145,320

16.1.2 600 x 600 x 3.15 mm cu.plate No. 99 13,049 1,291,851

Supplying and Providing mains with 3 nos. of 2.5 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.

Supplying and Providing mains with 3 nos. of 1.5 sq mm Cu. PVC insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.

Supply and installation of 3 compatement 225 mm x 38 mm under floor metal trunking/race way with all accessories made out of hot dip pre galvanized metal coated steel sheet equivalent to MK Ega (novar) make.

Supply and installation of 1 compatement 100 mm x 38 mm under floor metal trunking/race way with all accessories made out of hot dip pre galvanized metal coated steel sheet equivalent to MK Ega (Novar) make.

Supply and installation of 3 compartment Access outlet / service box of 250 x 250 x 60-75 mm with all accessories made out of high pressure die cast material suitable for above race ways equivalent to MK Ega (Novar) make.

Supply and installation of 3 compatement 100 mm x 50 mm wall trunking/race way with cover and all accessories made out of PVC equivalent to MK (premier) make.

Supplying, erecting, connecting, testing and commissioning of Following type Light Fixture with all necessary Hardware, Internal Wiring with Lamp,Ballast etc. all required accessories Complete in all respect.

Presence detector for lighting control non regulating type high performance having detection area not less than 6 mtr dia at 2.4 mt ht. equivalent to wipro make MS 1200PFmkII complete in all repect with necessary wiring.

Presence detector for analogue dimmable ballast regulating type high performance having detection area not less than 6 mtr dia at 2.4 mt ht. equivalent to wipro make MS 2001AF complete in all repect with necessary wiring.

Supply,Installation, testing and commissioning following sizes ceiling Fans without fan regulator.

36/42" Dia Sweep Ceiling Fan with Fan Hook as per approved colour & equivalent to crompton make high speed type...

48" Dia Sweep Ceiling Fan with Fan Hook as per approved colour & equivalent to crompton make high speed type...

56" Dia Sweep Ceiling Fan with Fan Hook as per approved colour & equivalent to crompton make high speed type...

Additional fan rod made out of 10 guage GI pipe with all necessary painted and required accessories for fan suspention.

Supply, Installation,testing and commissioning of following sizes Exhaust Fans of approved make

Light duty 225/305 mm. diameter propeller exhaust fans single phase 1400 RPM.

Heavy duty 305 mm. diameter propeller exhaust fans single phase 1400 RPM.

Heavy duty 450 mm. diameter propeller exhaust fans single phase 1400 RPM. With M.S. louvre shutter of the exhaust fan

Providing earthing stations for equipment earthing as shown and specified in drawing for equipment complete with :

Page 35: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 35 of 53

Sr. No. Item Description Unit Quantity Rate Amount

16.1.3 450 x 450 x 3.15 mm cu.plate No. 5 12,046 60,230

16.2 Earth wire/strips :

a) Fixing accessories.

16.2.1 25 x 3 mm cu. strip Rmtr 2,125 306 650,250

16.2.2 32 x 6 mm cu. strip Rmtr 160 772 123,520

16.2.3 50 x 6 mm cu. strip Rmtr 160 1,208 193,280

16.2.4 No.8 gauge bare cu. earth wire Rmtr 3,365 56 188,440

16.2.5 No. 108 679 73,332

Sub Total 16.0..... 2,726,223

17 Telephone And Data Distribution

17.1 PVC Conduits

17.1.1 Rmtr 25,530 43 1,097,790

17.1.2 Rmtr 100 90 9,000

17.2 Cabling

17.2.1 Rmtr 160 80 12,800

17.2.2 Rmtr 2,810 104 292,240

17.2.3 Rmtr 2,160 134 289,440

17.2.4 Rmtr 1,465 248 363,320

17.2.5 Rmtr 1,860 497 924,420

17.2.6 Rmtr 50 962 48,100

17.2.7 7,300 90 657,000

17.3 Tag Blocks

17.3.1 No. 77 822 63,294

17.3.2 No. 25 1,075 26,875

17.3.3 No. 16 2,350 37,600

Supply and laying cu. earthing required size strips for interconnecting the earthing stations, panels, DB's etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with :

b) Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes.

Earth Link : 38mm x 6 mm 1ft Long Cu.earth link fixed by necessary screws on wall.

Supply, installation, connection, testing and commissioning of telephone and data network system.The unit rate considered on running meter basis includes supply, laying, connection, testing and commissioning of multipair telephone/data cables through rigid PVC conduit from tag block/HUB of each block to MDF located in the data room/near EPABX system. The telephone cable shall be installed in a concealed manner in the vertical riser including supply & fixing tag block with KRONE type terminal Junction box of specified make.

Supply & laying of 25 mm dia. Open/conceal manner heavy guage rigid PVC pipe.

Supply & laying of 40 mm dia. Open/conceal manner heavy guage rigid PVC pipe.

Supplying and Laying of 0.5 mm dia Annealed copper 5 pair armoured telephone cable where ever required in prelaid conduit or clampped in open manner or clampped in open manner

Supplying and Laying of 0.5 mm dia Annealed copper 10 pair armoured telephone cable where ever required in prelaid conduit or clampped in open manner.

Supplying and Laying of 0.5 mm dia Annealed copper 20 pair armoured telephone cable where ever required in prelaid conduit or clampped in open manner.

Supplying and Laying of 0.5 mm dia Annealed copper 50 pair armoured telephone cable where ever required in prelaid conduit or clampped in open manner.

Supplying and Laying of 0.5 mm dia Annealed copper 100 pair armoured telephone cable where ever required in prelaid conduit or clampped in open manner.

Supplying and Laying of 0.5 mm dia Annealed copper 200 pair armoured telephone cable where ever required in prelaid conduit or clampped in open manner.

Supplying and Laying outdoor 24 count armoured fiber cable for computer Data connectivity equivalent to systimax make teraspeed plenum code no 5125 024A WPBK having appx outside diameter of 11 mm where ever required in prelaid conduit or in open manner.

Supply & fixing of 10 pair tagblock with KRONE with fabricated CRCA powder coated junction box of size 120x170x100 with two no. of pad-lock.

Supply & fixing of 20 pair tagblock with KRONE with fabricated CRCA powder coated junction box of size 120x170x100 with two no. of pad-lock.

Supply & fixing of 50 pair tagblock with KRONE with fabricated CRCA powder coated junction box of size 260x225x100 with two no. of pad-lock.

Page 36: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 36 of 53

Sr. No. Item Description Unit Quantity Rate Amount

17.3.4 No. 4 4,202 16,808

17.3.5 No. 1 11,677 11,677

17.3.6 No. 1 61,648 61,648

17.4 Telephone / DATA Point Wiring

17.4.1 Rmtr 29,320 27 791,640

17.4.2 Rmtr 24,780 28 693,840

17.5 Telephone / Data Outlet Point

17.5.1 No. 793 148 117,364

17.5.2 No. 821 183 150,243

Sub Total 17.0..... 5,665,099

18 Miscellaneous

18.1 PVC PIPES

18.1.1 Rmtr 1,080 43 46,440

18.1.2 Rmtr 420 60 25,200

18.1.2 Rmtr 290 74 21,460

18.1.3 Heavy gauge pipe in Open / Concealed manner minimum 50 mm dia. Rmtr 200 101 20,200

18.1.4 Heavy gauge pipe in Open / Concealed manner minimum 75 mm dia. Rmtr 365 150 54,750

18.1.5 Rmtr 135 173 23,355

18.1.6 Rmtr 58 386 22,388

Sub Total 18.0..... 213,793

19 External Lighting

19.1 Poles

19.1.1 No. 123 21,919 2,696,037

2) 40 mm diameter GI pipe for each cable entry .

4) Foundation Concrete coping with base plate.

5) Sprial/Coil Type Earthing and painting.

6) Excavation for erection of poles.

19.1.2 No. 505 7,734 3,905,670

Supply & fixing of 100 pair tagblock with KRONE with fabricated CRCA powder coated junction box of size 450x250x100 with two no. of pad-lock.

Supply & fixing of 200 pair tagblock with KRONE with fabricated CRCA powder coated junction box of suitable size

Supply & fixing of 1000 pair tagblock with KRONE with fabricated CRCA powder coated junction box of suitable size

Supply and laying of specified make Cat 6 Computer data wire to be done in prelaid PVC pipe / raceway , but without the cost of raceway or pipe ( the wire is to be drawn from server/switch to outlet point)

Supply and laying of specified make 0.5mm dia Annealed copper cond. 5 pair telephone wire of specified make to be done in prelaid PVC pipe of 25 mm dia / raceway of specified make, but without the cost of raceway or pipe ( the wire is to be drawn from Krone connector of respective area to outlet point)

Supplying, installing, testing and commissioning of one telephone point to be done with telephone outlet socket RJ-11 (jack type) and box of the specified make.

Supply and Installation of Single I/O plate with 1 no of RJ 45 Cat 6 I/O socket on same plate and with powder coated MS base box suitable for Computer Data outlet.

Supplying and laying following sizes PVC pipe of approved make in open / recess manner including execavation and back filling (if required) as per layout and drawing and re-filling the trenches etc. complete as directed.

Heavy gauge pipe in Open / Concealed manner minimum 25 mm dia with GI pulling wire.

Heavy gauge pipe in Open / Concealed manner minimum 32 mm dia with GI pulling wire.

Heavy gauge pipe in Open / Concealed manner minimum 40 mm dia with GI pulling wire.

Heavy gauge pipe in Open / Concealed manner minimum 100 mm dia.

Heavy gauge pipe in Open / Concealed manner minimum 150 mm dia.

Supply & installation of 9.0 Mtr long GI street light pole with medium class GI pipe duly pianted with two primer and coats of aluminium paint complete with base plate and single/double arm as per requirment complete in all respect with followings.

1) Water tight Junction box equivalent to hensel make K9250 with 8 way connector and 2A MCB (separate for each light fixtures).

3) Wiring up to the light fixture from the junction box using 3nos x 1.5 sq.mm. flexible copper wires of specified make.

Supply & installation of 3.5 Mtr long GI street light pole with medium class GI pipe duly pianted with two primer and coats of aluminium paint complete with base plate complete in all respect with following

Page 37: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 37 of 53

Sr. No. Item Description Unit Quantity Rate Amount

2) 40 mm diameter GI pipe for each cable entry .

4) Foundation Concrete coping with base plate.

5) Sprial/Coil Type Earthing and painting.

6) Excavation for erection of poles.

19.2 Street light fixture

19.2.1 Light Fixture Type C with basic rate as specified separately No. 150 12,222 1,833,300

19.2.2 Light Fixture Type D with basic rate as specified separately No. 400 42,059 16,823,600

19.2.3 Light Fixture Type E with basic rate as specified separately No. 101 59,942 6,054,142

19.3 Street light panel

19.3.1 External Lighting Panel - 1 No. 1 51,246 51,246

As per attached Single Line Diagram

19.3.2 External Lighting Panel - 2 No. 1 33,521 33,521

As per attached Single Line Diagram

19.4 Section feeder Pillar ( Outdoor Type) No. 4 88,057 352,228

As per attached Single Line Diagram

Sub Total 19.0..... 31,749,744

20 Television Distribution

20.1 PVC Conduits

20.1.1 Rmtr 3,770 43 162,110

20.1.2 Rmtr 90

20.2 Cabling

20.2.1 Supplying and Laying of RG 6 TV cable in prelaid conduit Rmtr 3,600 38 136,800

20.2.2 Supplying and Laying of RG 11 TV cable in prelaid conduit Rmtr 4,130 44 181,720

20.3 Junction box / Splitter

20.3.1 Supply & fixing of 3/4 way splitter No. 107 713 76,291

20.3.2 Supply & fixing of 6 way splitter No. 12 1,003 12,036

20.3.3 Supply & fixing of 8 way splitter No. 6 2,327 13,962

20.3.4 Supply & fixing of 16 way splitter No. 6 3,922 23,532

20.4 Television Outlet Point

20.4.1 No. 152 208 31,616

Sub Total 20.0..... 638,067

1) Water tight Junction box equivalent to hensel make K9250 with 8 way connector and 2A MCB (separate for each light fixtures).

3) Wiring up to the light fixture from the junction box using 3nos x 1.5 sq.mm. flexible copper wires of specified make.

Supplying, erecting, connecting, testing and commissioning of following type Street Light Fixture with all necessary Hadware, Internal Wiring with Lamp,Ballast etc. all required accessories Complete in all respect.

Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning double compartmentalized Double door type section feeder piller with IP 55 protection & should be powder coated fabricated from 10 Guage CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangment. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Architect/ Consultant. All civil work including RCC platform for section pillar should be in scope of Electrical contractor complete in all respect as per detail drawing and directed by engineer incharge.

Supply, installation, connection, testing and commissioning of television system with supplying of television cables as per specification and drawings. The unit rate considered on running meter basis includes supply, laying, connection, testing and commissioning of television cables through rigid PVC conduit from junction of Data Room. The cable shall be installed in a concealed manner in the vertical riser including supply & fixing splitter / Junction box of specified make.

Supply & laying of 25 mm dia. Open/conceal manner heavy guage rigid PVC pipe.

Supply & laying of 40 mm dia. Open/conceal manner heavy guage rigid PVC pipe.

Supplying, installing, testing and commissioning of one television point to be done with television outlet socket and box of the APPROVED make.

Page 38: SPCL Offer 9(New)_03.12.09

Tender DocumentsAga Khan Academy, Hyderabad

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 38 of 53

SUMMARY OF IBMS WORKS

Sr. No. Description Total Amount (Indian Rupees)

1 Section 01 - Fire Alarm System 16,676,595

2 Section 02 - Public Address System 14,959,473

3 Section 03 - CCTV System 7,830,375

4 Section 04 - Access Control System 5,315,934

5 Section 05 - Gas Based Fire Suppression System 1,381,738

6 Section 06 - Water Leak Detection System 2,054,829

7 Section 07 - Extinguishers 541,795

8 Section 08 - Networking 6,421,813

9 Section 09 - Building Management System 8,034,172

Total Amount: 63,216,724

Amount in Words:

Signature of Authorised Signatory Stamp of the Bidder

Page 39: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 39 of 53

BILL OF QUANTITIES - IBMS WORKS

Sr. No. Item Description Unit Quantity Rate Amount

SECTION 1 - Fire Alarm System

1.0

Large LCD display minimum 80 Character

Fully networkable, true peer to peer,with builtin Network Card

1.0.1 150 Detectors + 50 Devices Set 7 259,969 1,819,783

1.0.2 300 Detectors + 100 Devices Set 5 Inc

1.0.3 450 Detectors + 100 Devices Set 1 Inc

1.0.4 600 Detectors + 100 Devices Set 500,771

1.1 Nos. 1,773 3,244 5,751,612

1.2 Nos. 4,213

1.3 Nos. 164 2,605 427,220

1.4 Nos. 90 125 11,250

1.5 Nos. 230 5,746 1,321,580

1.6 Coventional Sounders 85 DB minimum at 10 feet . Nos. 262 1,800 471,600

1.7 Coventional Hooter with Strobe flasher 110 Cd Nos. 35 3,029 106,015

1.8 Monitor Modules in suitable ABS Plastic glossy Box. Nos. 100 2,562 256,200

1.9 Control/Relay Modules in suitable ABS Plastic glossy Box. Nos. 200 3,810 762,000

1.1 Fault Isolator Module,in suitable ABS Plastic glossy Box. Nos. 200 2,707 541,400

1.11 Nos.

1.11.1 800 VA Nos. 5 28,728 143,640

1.11.2 1200 VA Nos. 5 28,728 143,640

1.11.3 1800 VA Nos. 1 63,059 63,059

1.11.4 2000 VA Nos. 63,059

1.12 Nos. 1 104,474 104,474

1.13

1.13.1 1P x 1.5 mm2 Mtrs 23,270 36 837,720

1.13.2 1Px 2.5 mm2 Mtrs 5,000 50 250,000

1.14 Mtrs 10,000 109 1,090,000

1.15

1.15.1 4 way with 8 Terminals Nos. 26 679 17,654

1.15.2 8 way with 12 Terminals Nos. 13 1,077 14,001

Supply & Installation Testing ,commissioning of , Analouge Addressable Main Fire Alarm with Power supply & battery backup complete as per following features:

Adequate Loop Capacity to accommodate following Detectors& Devices .

Shall integrate Control,Monitor,Relay modules,Duct Detectors,Beam Detectors,Flame detectors.

System network shall be Web Enabled for Monitoring thru Intranet/Internet

Battery of 48 hrs backup in normal condition,+ 1 hr backup with 25% Loop under fire condition.

Addressable type OPTICAL smoke detector with sensitivity range of 0.5% to 2.35% per foot with base & MS Powder coated Junction Box

Addressable type MUILTISENSOR smoke detector with heat sensing intelligent type capable to set desired alogrithms,with base & MS Powder coated Junction Box

Addressable type Heat detector of rate of rise temperature detection of 15 degree F to 20 degree F per minute or Fixed temerature with base & MS Powder coated Junction Box. Remote response indicator having twin LED flush mounted on false ceiling/wall

Addressable Manual Pull station with Reset Lock & Key arrangment with back box.

Online UPS suitable for PA & Fire Panels with 30 mts backup ,with battery Charger & Battery Backup.

Network Annunciation Panel with minimum 640 character display for monitoring & controlling other Panels on the network loop with Power supply. Peer To Peer Networked with all main panels, such that the status of the entire system shall be available on individual Annunciator.

SLC Cables : Stranded Copper conductor,PVC insulated Twisted,FRLSPVC Sheathed 650 V as per IS 694.

Network Cable : 2P x 1.5 mm2, Stranded Copper conductor,PVC insulated,individual + overall Sheilded,Armoured FRLS sheathed Cable 650 V as per IS 1554

ABS Plastic Junction Box with DIN rail & elmex 1.5 Sq.mm Terminals with Lock & Key arrangement approved for outdoor use IP 66

Page 40: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 40 of 53

Sr. No. Item Description Unit Quantity Rate Amount

1.16

1.16.1 25mm Mtrs 23,270 52 1,210,040

1.16.2 32mm Mtrs 5,000 65 325,000

1.17 Set 1 970,956 970,956

1.18 BACnet Integration Card with necessary Hardware & software Set 123,302

1.19 Set 1 37,751 37,751

Sub Total 1.0 16,676,595

SECTION 2 - PUBLIC ADDRESS SYSTEM

2.0 Speakers

2.0.1 6 Watts Output suitable for flush mounting Nos. 191 1,890 360,990

2.0.2 6 Watt Output wall mount with metal Box Nos. 783 2,521 1,973,943

2.0.3 Nos. 50 3,530 176,500

2.0.4 10W Wallmount Music cabinet speaker Nos. 224 2,963 663,712

2.1 Microphones

2.1.1 Nos. 1 158,362 158,362

2.1.2 Nos. 2 32,722 65,444

2.1.3 Wireless Microphone for Playgrounds 2 15,840 31,680

2.2 Network Controllers

2.2.1 Network controller - 4 zone with following features Set 15 205,108 3,076,620

Accomodates 5 set of Amplifiers/ zones

Accomadates 96 Zone Call stations & can be cascaded upto 32 nodes

Automated Evacuation message facility

Networkable to 99 such Controllers.

EN60849 & BS5839 part 8 compliant

2.2.2 Nos. 1 261,920 261,920

2.2.3 Nos. 2 90,804 181,608

2.3

2.3.1 240W single channel Set 24 54,753 1,314,072

2.3.2 480W single channel Set 10 67,680 676,800

2.3.3 120W single channel Set 3 53,997 161,991

2.4 TCP/IP Audio distribution system comprising of :-

2.4.1 TCP/IP software server with GUI EN60849 & BS5839 part 8 compliant Set 1 117,661 117,661

2.4.2 Set 1 49,088 49,088

2.4.3 Set 10 114,477 1,144,770

2.5 Set 1 20,358 20,358

FRPVC Medium Conduit to be laid concealed in ceiling/walls & Flexible Conduits wherever required complete with Cable glands,ferruls & end terminations

Touch Screen display Panel with dymanic Graphics with complete monitoring of the System components on Monitor with required configuration 17" Monitor with Interface for RS 485/TCP/IP complete

Beam Detector set (transmitter + Receiver) 70 Mtr x 15 Mtr with Power supply complete with test Switch & key.

METAL GRILL speakers with line matching transformer for direct connecting to 100/70 V output line.

20W ABS Weatherproof Horn speakers with 100V line matching transformer, IP66.

96 Zone Touchscreen Call Station with goose neck Microphone with zone selection & all call selection to be connected with the network controller with music routing facility, automatic pre-recorded message broadcast, Complying to EN60849 & BS 5839 part 8

Remote paging 8 Zone RS 485 based digital microphone complying to BS 5839

Microcontroller based with built in DSP, 4x4 matrix, switching, pre-recorded message store, expandable to 256 zones,

Audio monitoring switchover system controller with single audio channel, allows to connect upto 16 zones, EN60849 & BS5839 part 8 compliant

Zone switcher for individual zone selection througn the automatic switching of the relevant 100V speaker line to the corresponding 100V amplifier output, EN60849 & BS5839 part 8 compliant

D class Digital Amplifiers with 230 VAC networkable with all interconnecting Cables with following outputs :

TCP/IP remote station software license, including 1 Out TCP/IP audio exstreamer EN60849 & BS5839 part 8 compliant

Control station software license, including 1 In TCP/IP audio in-streamer EN60849 & BS5839 part 8 compliant

Music Source with AM/FM/ CD Changer with optic firbre output complete with interconnecting Cables.

Page 41: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 41 of 53

Sr. No. Item Description Unit Quantity Rate Amount

2.6

2.6.1 2C x 1.5 mm2 Mtrs 14,630 36 526,680

2.6.2 2Cx 2.5 mm2 Mtrs 2,500 50 125,000

2.7 Set 1 95,039 95,039

2.8

2.8.1 4 way with 8 Terminals Nos. 90 679 61,110

2.8.2 8 way with 12 Terminals Nos. 45 1,077 48,465

2.9

2.9.1 25mm Mtrs 16,190 52 841,880

2.9.2 32mm Mtrs 2,500 65 162,500

2.30 Volume Control suitable for 10 Watts Operation with Back box Nos. 39 2,130 83,070

2.31 Set 15 41,337 620,055

2.32 Set 45 43,559 1,960,155

Sub total 2.0 14,959,473

SECTION 3 - CCTV System

3.0 Lot 1 993,228 993,228

3.1 Nos. 35 35,596 1,245,860

3.2 Nos. 12 219,997 2,639,964

3.3 Lot 1 516,582 516,582

3.4 Lot 1 515,795 515,795

3.5 Lot 1 633,217 633,217

3.6 19" colour TFT monitor for above client workstation Nos. 4 36,952 147,808

3.7 32" colour TFT monitor for above client workstation Nos. 5 60,191 300,955

3.8 CAT 6 Patch Chords within the BMS Room Lot 1 20,587 20,587

3.9 Equipment rack / Console as per requirement Lot 1 103,747 103,747

3.10 Mtrs 2,500 40 100,000

3.11 Nos.

3.11.1 2 way with 2 Terminals Nos. 20 570 11,400

Stranded Copper conductor,PVC insulated ,FRLSPVC Sheathed 650 V as per IS 694.

Central Monitoring Work Station Client with Core 2 Duo Intel processor with minimum 160Gb HDD, 1 GB RAM, 19" TFT Monitor, DVD Writer, two serial and one parallel ports, multimedia speakers, infrared mouse; Work station shall be preloaded with requisite MS Windows Licensed software compatible with the BMS platform

ABS Plastic Junction Box with DIN rail & elmex 1.5 Sq.mm Terminals with Lock & Key arrangement approved for outdoor use IP 66

FRPVC Medium Conduit to be laid concealed in ceiling/walls & Flexible Conduits wherever required complete with Cable glands,ferruls & end terminations

PA Rack suitable for 1 Network Controller,Amplifiers,Switchers & related accessories located per building/Cluster of Buildings with ventilation & openable glass door in front complete with interconnecting Cables

Mounting Poles for outdoor Horn Speakers,fabricated of GI ERW Medium Pipes of 80mmx2 mtr/65x2mtr/50x2mtrdiameter with total height of 6 Mtrs with flanged conection at the bottom with RRC foundation of 330x300x800 mm deep includng excavation & backfilling complete.

Network video management software license to support up to 70 cameras, 40 camera licenses, 5 user licenses, Failover directory, Failover recording, Virtual Matrix capablity, Audio capablity, Maps and alarm management.

Hi-Resolution Mpeg4 video with Ethernet (CAT5) TCP/IP Communication Port and Power over Ethernet option, Two way audio, with varifocal lens 2.9mm - 10mm as per specifications.

Vandalproof Outdoor pole Mount Pan, Tilt and Zoom (PTZ), Hi-Resolution Mpeg4 video Day/Night and 23x optical 12x digital zoom with Ethernet (CAT5) TCP/IP communication port as per specifications.

Network video recorder server/servers with 2TB usable RAID5 storage storage as per specifications, and database/failover database server as required

Failover server/servers with 2TB usable RAID5 storage as per specifications, and database/failover database server as required

Client workstations as per specifications to accommodate one 19" monitors & two 32" Monitors in main control room, One 19" monitor & one 32" monitor each in 2 local control rooms with different content possiblity on each monitor i.e Multiplexed video, alarm video, maps, spot monitor function etc.

CAT 6 Cables with end Connections from Camera to LAN Switch to be laid in below PVC Conduits

ABS Plastic Junction Box with RJ 45 Jack connection 2 way with Lock & Key arrangement approved for outdoor use IP 66

Page 42: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 42 of 53

Sr. No. Item Description Unit Quantity Rate Amount

3.12

3.12.1 25mm Mtrs 2,500 52 130,000

3.12.2 32mm Mtrs 65

3.13 Nos. 12 1,976 23,712

3.14 Nos. 10 44,752 447,520

Sub total 3.0………. 7,830,375

SECTION 4 - ACCESS CONTROL SYSTEM

4.0

Variable card formats supported.

Multiple facility codes supported

Remote database administration

Remote alarm monitoring

Inbuilt database backup to facilitate offline use

RS-422 (4 wire) and RS-232 ) connectivity supported

Local, Global, Soft, Hard Anti-pass back supported

Automatic locking & unlocking of the doors

Battery Charger & Battery Backup for 4 hrs

4.0.1 2 Reader Controller Nos. 5 37,555 187,775

4.0.2 4 Reader Controller Nos. 19 46,798 889,162

4.1 Smart( i Class) Card Reader Nos. 70 4,394 307,580

4.2 Egress Switch Nos. 867

4.3 Nos. 53 5,472 290,016

4.3.1 Drop Bolt Nos. 2 3,151 6,302

4.4 Nos. 50 819 40,950

4.5 Magnetic Contacts Nos. 20 154 3,080

4.6 16 K(2KB) Contactless Smart Card with 2 Applications(iCLASS) Nos. 500 442 221,000

4.7 Nos. 1 91,998 91,998

4.8 Nos. 1 23,958 23,958

4.9 Set 1 554,396 554,396

FRPVC Medium Conduit with fittings concealed in ceiling/wall or GI Saddle Spacers at every 0,3 Mtrs & Flexible Conduits wherever required complete with Cable glands,ferruls & end terminations

Redundant Power Supply suitable for outdoor PTZ Camera`s with Input 230VAC +/- 10%,Output 12V +/- 2Volt,load regulation & line regulation less than 0.1%,Electronic protection against overload & short circuit,outout ripple less than 1 milli volt RMS,.

Mounting Poles for outdoor Camera`s,fabricated of GI ERW Medium Pipes of /100mmx2 mtr/80mmx2 mtr/65mm x2mtr/50mmx2mtr diameter with total height of 8 Mtrs with flanged conection at the bottom with RRC foundation of 330x300x1000 mm deep includng excavation & backfilling complete.

Network Intelligent 32 BIT Native Onboard IP Access Control & Alarm Management Panels for Smart Card or a group of Panels capable of controlling all the Card Readers as spec`s below:

Intelligent embedded network device for access control and alarm monitorin.

Firmware stored in flash memory that is easy to update on LAN Network.

Multiple card reading technologies supported, Proximity, Smart card, Biometric

Supports supervised inputs (door contacts, motion detectors, glass break sensors, and so on) and outputs (programmable auxiliary relay)

Electromagneitc Lock with builtin Magnetic contacts Doors. 600 lbs capacity

Emergency Release Switch in Green Polycarbonate housing,push to breakglass type.

Server Access Control Software:Licenced Enterprise version Server Software , to be loaded at the central Server,with real time communicator software ,specification of the Server to be specifed to the client to provide the same.

Client Access Control System Software, with real time communicator software, Configuration of required PC to be specified to Client to provide the same.

Central Work Station Server with Core 2 Duo Intel processor with minimum 240 GB HDD, 2 GB RAM, 19" TFT Monitor, DVD Writer, two serial and one parallel ports, multimedia speakers, infrared mouse; Work station shall be preloaded with requisite MS Windows Licensed software compatible with the BMS platform

Page 43: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 43 of 53

Sr. No. Item Description Unit Quantity Rate Amount

4.10 Set 1 95,039 95,039

4.11

4.11.1 8 c x 0.75 Sq.mm Mtrs 5,150 59 303,850

4.11.2 4c x 0.75 Sq.mm Mtrs 5,150 36 185,400

4.11.3 2c x 0.75 Sq.mm Mtrs 10,490 27 283,230

4.12

4.12.1 4 way with 8 Terminals Nos. 20 679 13,580

4.12.2 8 way with 12 Terminals Nos. 10 1,077 10,770

4.13

4.13.1 25mm Mtrs 15,150 52 787,800

4.13.2 32mm Mtrs 65

4.14 Set 8 127,506 1,020,048

Sub total 4.0……………… 5,315,934

SECTION 5 - GAS BASED FIRE SUPPRESSION SYSTEM

5.0 1 263,913 263,913

5.1 Novec 1230 Fire Protection Fluid, OEM Factory Fill in Kgs Nos. 75 4,492 336,900

5.2 Tank Bracket Assembly Nos. 1 7,263 7,263

5.3 Single-Tank Swivel Adaptor, 2 in with Discharge Hose Nos. 1 32,532 32,532

5.4 Electric Actuator Assembly Nos. 1 34,100 34,100

5.5 Local Manual Actuator Nos. 1 11,311 11,311

5.6 Nozzle, Brass, Drilled ( 1.25 in) - 360 degree Nos. 4 9,827 39,308

5.7 Nozzle, Brass, Drilled ( 1.5 in) - 360 degree Nos. 2 10,444 20,888

5.8 Nos. 1 5,811 5,811

5.9 Set 1 1,630 1,630

5.10 Lot 1 163,203 163,203

5.11 Cylinder Low Pressure Switch Nos. 1 4,498 4,498

5.12 Nos. 1 210,301 210,301

Cross Zoning with timer card ( 0-256 secs)

Input for low pressure switch connection

Abort/Release inputs

Manual & Standby Modes

Solenoid output of 2.0 Amps

Builtin Power supply

Battery backup of 24 AH

5.13 Conventional Optical Smoke Detectors with Bases Nos. 6 1,028 6,168

5.14 Release cum Abort Switch with key & lock Nos. 1 11,477 11,477

5.15

5.15.1 2C x 1.5 mm2 Mtrs 2,500 40 100,000

5.15.2 2Cx 2.5 mm2 Mtrs 55

5.16

Central Monitoring Work Station Client with Core 2 Duo Intel processor with minimum 160Gb HDD, 1 GB RAM, 19" TFT Monitor, DVD Writer, two serial and one parallel ports, multimedia speakers, infrared mouse; Work station shall be preloaded with requisite MS Windows Licensed software compatible with the BMS platform

Stranded Copper conductor,PVC insulated ,FRLSPVC Sheathed 650 V as per IS 694.

ABS Plastic Junction Box with DIN rail & elmex 0.75 Sq.mm Terminals with Lock & Key arrangement approved for outdoor use IP 66

FRPVC Medium Conduit to be laid concealed in ceiling/walls & Flexible Conduits wherever required complete with Cable glands,ferruls & end terminations

Boom Barrier Fixed- 2.5 mtr long ,made of 2mm zinc coated sheet steel Powder coated & base of SS with reflective tape strips,with opening time less than 2 sec`s,complete with fixed support post IP 55 Protection with manual maneovering.It shall also include operation with remote & a manul switch override.

NOVEC 1230 storage Tank & Valve assembly capacity suitable for storage of following aqty of agent, Empty CCOE Approved with low pressure switch provision & safety brust disc

Auto/Manual selector Switch with key lock arrangement in Glossy ABS Enclosure

LED type display sign board flashing with inbuilt Sounder "EVACUATE GAS RELEASED" & "DONOT ENTER"

Sch 40 Seamless ASTM 106 gr B, piping with 3000psi fittings ,rigid supports with angles,2 coats of Zinc primer & 3 coats of P.O red Paint.

Single Cross Zone ( 2 zone) Detection & Release Panel with following features:

Stranded Copper conductor,PVC insulated ,FRLSPVC Sheathed 650 V as per IS 694.

ABS Plastic Junction Box with DIN rail & elmex 1.5 Sq.mm Terminals with Lock & Key arrangement approved for outdoor use IP 66

Page 44: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 44 of 53

Sr. No. Item Description Unit Quantity Rate Amount

5.16.1 4 way with 8 Terminals Mtrs 2 679 1,358

5.16.2 8 way with 12 Terminals Mtrs 1 1,077 1,077

5.17

5.17.1 25mm Mtrs 2,500 52 130,000

5.17.2 32mm Mtrs 65

Sub total 5.0…………… 1,381,738

SECTION 6 - WATER LEAK DETECTION SYSTEM

6 Water Leak Sensor Cable - 5 Mtrs long with end connections Lenghts 100 5,065 506,500

6.1 Piezo Sounder -White 65db Nos. 1 3,029 3,029

6.2 Nos. 100 11,543 1,154,300

6.3

6.3.1 2C x 0.5 mm2 Mtrs 4,000 25 100,000

6.3.2 4Cx 0.5 mm2 Mtrs 1,000 31 31,000

6.4

6.4.1 25mm Mtrs 5,000 52 260,000

6.4.2 32mm Mtrs 65

Sub total 6.0……….. 2,054,829

SECTION 7 - EXTINGUISHERS

7.0 Nos. 11 5,669 62,359

7.1 Nos. 15 3,688 55,320

7.2 Nos. 198 2,142 424,116

Sub total 7.0…………… 541,795

SECTION 8 - NETWORKING

8.0 Nos. 1 227,424 227,424

8.1 Nos. 2 99,090 198,180

8.2 Nos. 36 13,167 474,012

8.3 Nos. 4 33,632 134,528

8.4 Nos. 20 66,663 1,333,260

8.5 10/100 Ethernet Media Convertor - Single Mode SC Type Nos. 18 6,178 111,204

8.6 Nos. 18 1,983 35,694

8.7 6 Core Outdoor Steel Armoured Single Mode Optical Fiber Cable Mtrs 20,000 95 1,900,000

8.8 Fiber Pigtails - Single Mode (3 Meters) SC Type Nos. 456 947 431,832

8.9 Fiber Patch Cords - Single Mode Duplex (3 Meters) SC-LC Type Nos. 76 2,088 158,688

8.10 Rack Mount LIU - 12 Ports with SC-SC Type Adapters Nos. 20 9,364 187,280

8.11 Rack Mount LIU - 24 Ports with SC-SC Type Adapters Nos. 1 15,759 15,759

8.12 24 Ports CAT 6 PatchMax Panel Nos. 21 9,017 189,357

8.13 CAT 6 Patch Cords- 2 Meters Nos. 480 289 138,720

8.14 CAT 6 I/O Nos. 4 326 1,304

8.15 CAT 6 Cable to be laid in Medium Conduits Nos. 5,000 37 185,000

FRPVC Medium Conduit with fittings & GI Saddle Spacers at every 0,3 Mtrs & Flexible Conduits wherever required complete with Cable glands,ferruls & end terminations

Water Leak Module with 230 VAC input & output inform of relay on water leak cable activation,housed is ABS Plastic Ju, Box - IP 66

Stranded Copper conductor,PVC insulated ,PVC Sheathed 650 V as per IS 694.

FRPVC Medium Conduit with fittings & GI Saddle Spacers at every 0,3 Mtrs & Flexible Conduits wherever required complete with Cable glands,ferruls & end terminations

4.5 KG CO2 fire Extingusher with horn & sqeez grip handle,CCOE approved cylinder with wall mounting bracket .

5 Kg- ABC Type stored pressure fire Extingusher with safety brust disc & NRV for pressure gauge on wall with mounting bracket .

9 ltr Water Type cartridge operated with safety brust disc & NRV for pressure gauge on wall with mounting bracket .

Core Switch - 28 Ports 2 X 10/100/1000 Ethernet Ports, 2 X Gigabit SFP Ports & 100 X 100 FX Fiber SFP Ports, Layer 3, VLAN, Fully Managed, Stackable (upto 8 Units), Supports Clustering, 12.8 Gbps Switching Capacity, RADA, Auto Voice LAN, Auto VLAN, Secured Managed, Layer & 2 Support

Giga Switch - 12 Ports 8 x 10/100/1000 Ports , 4 x Giga SFP Combo Ports, 4 X 100 MB SFP Slots, 1 X 10 GB SFP Slot, Support for Clustering, 44 Gbps Switching Capacity, RADA, Auto Voice LAN, Auto VLAN, Secured Managed, Layer & 2 Support

100 FX - 100 MBPS Fiber SFP Module 100BASE-LX SFP Transceiver - Single Mode LC Type

Giga Fiber SFP Module 1000BASE-LX SFP Transceiver - Single Mode LC Type

26 Ports Layer 2 Network Switch with 24 X 10/100 Ports with POE , 2 X 10/100/1000 Giga Combo SFP Ports, 2 X 100MB SFP Slots, RADA , Auto VLAN, Secured Managed

Outdoor Junction Boxes for Media convertors, Fiber LIU & Termination

Page 45: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 45 of 53

Sr. No. Item Description Unit Quantity Rate Amount

8.16 9 U - Wall Mount Network Nos. 20 6,736 134,720

8.17 42 U - 800 X 1000 Network/ Server Rack Nos. 1 53,851 53,851

8.18 RJ 45 Jack Holder with face plate & back Box Nos. 500 512 256,000

8.19

8.19.1 25mm Mtrs 5,000 51 255,000

8.19.2 32mm Mtrs 57

Sub total 8.0…………… 6,421,813

SECTION 9 - Building Management System

9.0 IBMS Server and work station Hardwares

9.0.1 Set 1 87,119 87,119

9.0.2 Set 2 55,440 110,880

9.0.3 600 dpi or better A3 size Ink Jet colour printer 1 28,512 28,512

9.1 Customization of IBMS "Development and Runtime" Softwares

9.1.1 1 651,209 651,209

9.1.2 Run time version BMS software for with license (edit feature) License 2 Inc

9.1.3 License 1 Inc

9.1.4 License 1 76,626 76,626

9.1.5 Software customization to suit system requirement Lot 1 Inc

9.1.6

9.1.6.1 VRV System (BACNET over IP) Set 5 Inc

9.1.6.2 UPS System MP Panel Set 4 Inc

9.1.6.3 DG Set MP Panel Set 1 778,642 778,642

9.1.6.4 Substation Load Managers (MODBUS RTU over IP) Set 4 Inc

9.1.6.5 Field (Residence Blocks) Load Managers (MODBUS RTU over IP) Set 15 Inc

9.1.6.6 AutoChange Over Panel (MODBUS over IP) Set 1 Inc

9.1.6.7 Water Softening Plant Panel Set 1 Inc

9.2 IP based DDC Controller and hardware

9.2.1 Set

9.2.1.1 DDC 1 for ACAD Building Environmental System Set 1 44,533 44,533

9.2.1.2 DDC 2 for Sr ACAD Building Environmental System Set 1 21,019 21,019

9.2.1.3 DDC 3 for Jr ACAD Building Environmental System Set 1 21,019 21,019

9.2.1.4 DDC 4 for Sr ACAD Art Block Environmental System Set 1 21,019 21,019

9.2.1.5 DDC 5 for ACAD Building UPS System Set 1 21,019 21,019

9.2.1.6 DDC 6 for Jr ACAD UPS System Set 1 21,019 21,019

9.2.1.7 DDC 7 for Sr ACAD UPS System Set 1 21,019 21,019

9.2.1.8 DDC 8 for Nursery UPS System Set 1 21,019 21,019

FRPVC Medium Conduit to be laid concealed in ceiling/walls & Flexible Conduits wherever required complete with Cable glands,ferruls & end terminations

Central Work Station Server with Core 2 Duo Intel processor with minimum 240 GB HDD, 2 GB RAM, 19" TFT Monitor, DVD Writer, two serial and one parallel ports, multimedia speakers, infrared mouse; Work station shall be preloaded with requisite MS Windows Licensed software compatible with the BMS platform

Central Monitoring Work Station Client with Core 2 Duo Intel processor with minimum 160Gb HDD, 1 GB RAM, 19" TFT Monitor, DVD Writer, two serial and one parallel ports, multimedia speakers, infrared mouse; Work station shall be preloaded with requisite MS Windows Licensed software compatible with the BMS platform

Development Version (server version with full function edit facility) unlimited tags BMS software supporting LON/BACNET protocol as specified with all monitoring/control modules including but not limited to full function Report / Trending / Alarms / MIMIC / LAN / WAN modules

User License

Additional Web browser module with unlimited user capability,to be installed at Router level

Additional email alarm notification module with unlimited user capability

System Data Integrators to acquire soft data over IP for following Devices

IP based Direct Digital controllers supporting either - BACNet or LonWork - over IP communication platform designed for the required IO paramteres (as per Annexure 1), housed in IP 55 MS powder coated panel duly internally - wired and tested - at OEM works; the DDCs offered shall be with LCD display of suitable characters and membrane function keys for local programming and control; alternatively, blind DDCs with mobile OP panel shall have dedicated OP to one DDC each; DDCs shall be supplied for following

Page 46: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 46 of 53

Sr. No. Item Description Unit Quantity Rate Amount

9.2.1.9 DDC 9 for DG Set Set 1 33,499 33,499

9.2.1.10 DDC 10 for Electrical System Set 1 28,507 28,507

9.2.1.11 DDC 11 to DDC 24 - Fire and Leak Detection for 14 clusters Set 14 21,019 294,266

9.2.1.12 DDC 25 - Fire and Leak Detection for Resi Cluster Set 1 189,165 189,165

9.2.1.13 DDC 26 for Water Management Set 1 94,059 94,059

9.2.1.14 DDC 27 for ACAD FFG System Set 1 21,019 21,019

9.2.1.15 DDC 28 for Sr ACAD FFG System Set 1 21,019 21,019

9.2.1.16 DDC 29 for Jr ACAD FFG System Set 1 21,019 21,019

9.2.1.17 DDC 30 for Athletic Block FFG System Set 1 21,019 21,019

9.2.1.18 DDC 31 for Acad Server Room Fire Suppression System Unit 1 21,019 21,019

9.2.1.19 Xenta OP panels for each DDC above Unit 31 14,539 450,709

9.2.1 Unit

9.2.1.1 With 4 UI & 2UO ( Universal Input/Outputs) Unit 31,310

9.2.1.2 With 8 UI & 4 UO ( Universal Input/Outputs) Unit 31,310

9.3 Pre Calibrated Field Devices

9.3.1 For Environmental System

9.3.1.1 Nos. 6 907 5,442

9.3.1.2 Nos. 5 8,390 41,950

9.3.1.3 Wall Mounted Ambient T+Rh transmitter for outdoor duty Nos. 1 8,390 8,390

9.3.2 DG Room Instruments

9.3.2.1 Ultra Sonic Level Transmitter for 5 M rating installed on Day Tank Nos. 2 105,537 211,074

9.3.2.2 SS Level switch for installation on tankage Nos. 16,040

9.3.3 Nos. 20,937

9.3.4 Water Management Instruments

9.3.4.1 Absolute Pressure Transmitters - Borewell/Pumps Discharge Press Nos. 16 5,330 85,280

9.3.4.2 Ultra Sonic Level Transmitter for 5 M rating for UGR and ESR Nos. 2 105,537 211,074

9.3.4.3 water Differential Pressure switches Nos. 16 7,208 115,328

9.3.5 Fire Fighting System Instruments

9.3.5.1 Absolute Pressure Transmitters - Pumps Discharge Pressure Lot 8 5,330 42,640

9.3.5.2 Ultra Sonic Level Transmitters for 5 M rating for Fire Tank Level 5 105,537 527,685

9.3.5.3 water Differential Pressure switches Nos. 8 7,208 57,664

9.4 Calibration Work

Lot 1 89,531 89,531

9.5 Cabling and Conduits

9.5.1

9.5.1.1 8 c x 1.5 Sq.mm Mtrs 1,000 91 91,000

9.5.1.2 4c x 1.5 Sq.mm Mtrs 5,000 52 260,000

9.5.1.3 2c x 1.5 Sq.mm Mtrs 15,000 36 540,000

9.5.2

9.5.2.1 4 way with 8 Terminals Nos. 80 679 54,320

9.5.2.2 8 way with 12 Terminals Nos. 20 1,077 21,540

9.5.3 Mtrs 2,500 52 130,000

9.5.4

9.5.4.1 25mm Mtrs 20,000 52 1,040,000

9.5.4.2 32mm Mtrs 65

9.5.4.3 Supply/laying of GI perforated cable tray

9.5.4.3.1 100 x 50 Rmt 500 196 98,000

9.5.4.3.2 200 x 50 Rmt 300 355 106,500

9.5.4.3.3 300 x 50 Rmt 200 525 105,000

9.6 Fire Stoppings

Expansion Modules compatible for processors offered under above DDCs

Scope shall cover installation with all necessary fixtures and protection as per manufacturer's standards

Duct mounted Resistance Temperature Detectors for TFA Leaving Temp

Wall Mounted Combined T+Rh Transmitter for Server Room and UPS Rooms

Digital Energy Meters with back lit LCD real time display and MODBUS over IP Serial communication

Calibration of Field devices supplied under D : at site with documentation

Stranded Copper conductor,PVC insulated ,FRLSPVC Sheathed 650 V as per IS 694.

ABS Plastic Junction Box with DIN rail & elmex 1.5 Sq.mm Terminals with Lock & Key arrangement approved for outdoor use IP 66

CAT 6 Cables with end Connections from Camera to LAN Switch to be laid in below PVC Conduits

FRPVC Medium Conduit to be laid concealed in ceiling/walls & Flexible Conduits wherever required complete with Cable glands,ferruls & end terminations

Page 47: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 47 of 53

Sr. No. Item Description Unit Quantity Rate Amount

9.6.1 SQ.ft 50 5,226 261,300

9.6.2 Kg 500 1,621 810,500

Sub total 9.0………….. 8,034,172

Expanding Firestop Foam with upto 7 times expansion,repenetrable,to protectagainst fire,smoke,& water complete with dispenser,mixer,& cleaner.

Firestop Mortar -Fire resistance cement based thermal insulating Compound for Cable tray penetration

Page 48: SPCL Offer 9(New)_03.12.09

Tender DocumentsAga Khan Academy, Hyderabad

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09 Page 48 of 53

SUMMARY OF FIRE FIGHTING WORKS

Sr. No. Description Total Amount (Indian Rupees)

1 Section 01 - External Fire Fighting Works 2,199,083

2 Section 02 - Internal Fire Fighting Works 2,977,374

3 Section 03 - Automatic Sprinkler System 1,103,812

4 Fire Pumps and Accessories 435,405

Total Amount: 6,715,674

Amount in Words:

Signature of Authorised Signatory Stamp of the Bidder

Page 49: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 49 of 53

BILL OF QUANTITIES - FIRE FIGHTING WORKS

Sr. No. Item Description Unit Quantity Rate Amount

SECTION 1 - EXTERNAL FIRE FIGHTING WORKS

1 FIRE DOWNCOMMER SYSTEM

1.1

a) 100 mm dia Rmt 619 1,321 817,699

b) 80 mm dia Rmt 992

1.2

a) 100 mm dia Rmt 619 180 111,420

b) 80 mm dia Rmt 145

1.3

a) 100 mm dia Nos. 28 6,930 194,040

1.4

a) 100 mm dia Nos. 28 8,989 251,692

1.5 Each 24 34,343 824,232

SUB TOTAL - SECTION 1 2,199,083

SECTION 2 - INTERNAL FIRE FIGHTING WORKS

FIRE DOWNCOMMER SYSTEM/ DRY RISER

2.0

a) 25mm dia Rmt 46 402 18,492

b) 65mm dia Rmt 833

c) 80mm dia Rmt 47 1,027 48,269

d) 100mm dia Rmt 353 1,378 486,434

2.1 Nos. 66 10,305 680,130

2.3 Nos. 66 7,374 486,684

2.4 Nos. 66 7,782 513,612

2.5 Nos. 66 5,537 365,442

Providing and laying .G.I. pipes to IS:1239 (heavy class-C) in trenchs including all fittings like anchor fasteners, coupling bends elbows, tees etc weld on screwed joints as required (external : Below Ground)

Providing pipe protection for underground pipes from corrosion, paining pipe with PYPKOTE primer and covered with PYPKOTE antiicorrosive tape (4mm thick) as per boq.

Providing and fixing short body double flanged cast iron, butterfly valve complete with C.I. body, EPDM disc seal, SS retainer ring, carbon steel disc & shaft and lever conforming to BS 5155 and suitable for PN 16 including companion flanges.

Providing and fixing double flanged cast iron type Dual plate spring operated Check valve conforming to API 596/598 with CI body, CS plate & SS spring & suitable for 16 kg /cm2. with companion flanges.

Gun-metal Fire Brigade inlet connection for connecting to fire hydrant ring main consisting of 2 Nos. 63mm dia instantaneous type male couplings with built-in check valves and 100mm dia, flanged outlet complete with bolts, nuts, and rubber insertions as per requirement.

Providing, fixing and testing black mild steel G.I. Heavy duty (Class 'C') pipes (IS:1239) and fitting like flanges, tees, elbows, bend junctions, reducers etc, clamp structural steel supports as required / directed at site including cutting and making all comp.

Providing & fixing 63 mm dia 2 nos. x 7.5 mtr. Long Reinforced rubber lined hose pipe with 20 mm bore nozzle including gunmetal male & female instantaneous type coupling & branch pipe approved by fire authority.

Providing & fixing fire single headed internal hydrant valve with instantaneous Gun metal couplings of 63mm dia cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal cap and chain as required.

Supplying and fixing TAC approved first aid hose reel including 30 meter long 20mm internal dia rubber lined hose reel tubing, 25 mm dia stop valve, shut off nozzle of sufficient length at one end of this hose and leaded tin, bronze rings and adapter to get in to the instanta-neous female coupling complete with suitable drawn brackets, hub etc as required. the hose reel strictly confirm to IS:884 - 1985

S.S. 304 Cabinet (to enclose above draw-out connection) fabricated from 16g sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on wall as required (size . 750 mm x 600mm x 450mm).

Page 50: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09Page 50 of 53

Sr. No. Item Description Unit Quantity Rate Amount

2.6

a) 25mm dia Nos. 86 818 70,348

2.7

a) 100 mm dia Nos. 37 6,930 256,410

2.8 Nos. 31 1,663 51,553

SUB TOTAL - SECTION 2 2,977,374

SECTION 3 - AUTOMATIC SPRINKLER SYSTEM

3.0

a) 25mm dia Rmt 802 402 322,404

b) 32mm dia Rmt 122 449 54,778

c) 40mm dia (Including Drain Pipe) Rmt 234 519 121,446

d) 50mm dia Rmt 180 670 120,600

e) 65mm dia Rmt 152 833 126,616

f) 80mm dia Rmt 7 1,027 7,189

g)100mm dia Rmt 1,378

3.1

a) 20mm dia Nos 576

b) 25mm dia Nos 23 818 18,814

3.2 Nos 332 425 141,100

3.3 Nos 13 7,434 96,642

3.4 Nos 6 3,525 21,150

3.5 Flow Switches for each sprinkler tapping from riser complete with all acce Nos 13 5,621 73,073

SUB TOTAL - SECTION 3 1,103,812

SECTION 4 - FIRE PUMPS AND ACCESSORIES

4.0 Set 5 87,081 435,405

SUB TOTAL - SECTION 4 435,405

Providing and fixing fire authority approved ball valves with S.S. ball, PN 16 including all fittings required.

Providing and fixing cast iron butterfly valves with EPDM seat projection conforming to IS 5155, PN 16 including pipe flanges complete in all respect.

Providing, fixing, testing and commissioning of single acting 25mm dia., air release valve with all accessories,PN 16 including pipe flanges complete in all respect

Providing and fixing of G.I. heavy duty (Class 'c' pipes (IS:1239 Part - 1), and fitting like flanges (MS steel flanges at every 15m length and as required tees, elbows, bends, junctions, Reducers etc; clamps/ structural steel supports as required/directed at site including cutting & making good the walls, RCC work etc. cutting chases & filling the came with cement conc. 1:3:6 including painting the exposed pipes with desired shade of enamel over a coat of primer.

Providing and fixing fire authority approved ball valves with S.S. ball including all fittings required.

15mm dia, Quartzoid bulb type G.M. Spinkler Head (Pendent/Upright/Conventional, as required) set to operate at 68 C (UL/FM/LPC/TAC listed/ approved chrome plated complete with decorating plate (Ressette).

Providing, fixing, testing and commissioning 40mm diameter pipe with inspecting and testing assembly with gunmetal isolation valve gunmetal sight glass bypass valve

Providing, fixing, testing and commissioning 50mm diameter drain valve

Supply, Erection, testing and commissioning of centrifugal monoblock pump of approved make,which gives a discharge of 450 LPM of 40 mtrs head,with suitable electrical driven motor when running at 2900 rpm. When directly coupled to suitable HP TEFC motor also provision threaded coupling in suction and discharge lines for tubing. Including pump electric panel Sheet steel clad floor mounting control panel. control of 10 HP fire pumps, booster pumps having incoming isolating switch, branch HRC fuses, incoming voltmeter with selector switch and fuses, auto star delta starters with hand reset overload cum single phase preventor type relay for fire pump and DOL starters with hand reset overload cum single phase preventor type relay for booster pumps, ammeters to read current in any one phase, OFF/AUTO/MANUAL selector switches, various fault indicating lights such as pump trip due to overload, pressure switches,pressure gauge, fuse blow out etc., and alarms with hand reset push button which will automatically reset for the next cycle.

The alarm shall start when the fire hydrant starts on fire duty. The fire pump once started shall run continuously till manually switched off.

Page 51: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09

Page 51 of 53

ANNEXURE - I

RATES OF ADDITIONAL ITEMS

Sr. N0. Item description Unit Quantity Rate

QRO Cum 855

1.18.b.1 QRO Cum 340

1.18.b.2 QRO Cum 337

2.01.3.a QRO Cum 3 296

2.01.4.a QRO Cum 3 028

2.01.5.a QRO Cum 2 789

2.12.1.a QRO Cum 4 150

2.13.1.a QRO Cum 4 368

2.14.a1.a QRO Cum 4 618

4.11.a QRO Cum 340

4.13.a QRO Cum 339

4.14.a QRO Cum 339

9.39.a QRO sqm 1 331

1.16.a Same as item 1.16 above but using manufactured sand conforming to relevant I.S. codes

Rebate over item 1.18.a.1 for using rubble available on site on as-is-where-is basis. Rate shall include necessary cutting & sizing as required.

Rebate over item 1.18.a.2 for using rubble available on site on as-is-where-is basis. Rate shall include necessary cutting & sizing as required.

Same as item 2.01.3 but using manufactured sand conforming to relevant I.S. codes in suitable proportion with river sand, based on mix design with prior approval from consultants, subject to proportion of manufactured sand not exceeding 67% of river sand.

Same as item 2.01.4 but using manufactured sand conforming to relevant I.S. codes in suitable proportion with river sand, based on mix design with prior approval from consultants, subject to proportion of manufactured sand not exceeding 67% of river sand.

Same as item 2.01.5 but using manufactured sand conforming to relevant I.S. codes in suitable proportion with river sand, based on mix design with prior approval from consultants, subject to proportion of manufactured sand not exceeding 67% of river sand.

Same as item 2.12.1 but using manufactured sand conforming to relevant I.S. codes in suitable proportion with river sand, based on mix design with prior approval from consultants, subject to proportion of manufactured sand not exceeding 67% of river sand.

Same as item 2.13.1 but using manufactured sand conforming to relevant I.S. codes in suitable proportion with river sand, based on mix design with prior approval from consultants, subject to proportion of manufactured sand not exceeding 67% of river sand.

Same as item 2.14.a1 but using manufactured sand conforming to relevant I.S. codes in suitable proportion with river sand, based on mix design with prior approval from consultants, subject to proportion of manufactured sand not exceeding 67% of river sand.

Rebate over item 4.11 for using rubble available on site on as-is-where-is basis

Rebate over item 4.13 for using rubble available on site on as-is-where-is basis

Rebate over item 4.14 for using rubble available on siteon as-is-where-is basis

Same as item 9.39 above but fixing tile with cement based polymer adhesive like BAL or equivalent instead of 1:1 cement: sand mortar.

Page 52: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09 Page 52 of 53

ANNEXURE - II

Sr. N0. Item description Unit Quantity RateRATES OF ADDITIONAL ITEMSCivil Works:

2.09.b.1 Cum QRO 6 923

2.09.b.2 Cum QRO 6 691

2.12.1.b Cum QRO 4 074

2.13.1.b Cum QRO 4 136

2.14.a1.b Cum QRO 4 292

9.06.a Sqm QRO 1 292

9.06.b Sqm QRO 780

9.12.a

9.12.a.4 Sqm QRO 1 608

9.12.a.5 Sqm QRO 1 036

9.21 Sqm QRO 1 996

9.34.a.1 Cum QRO 4 282

9.34.a.2 Cum QRO 4 206

Same as item 2.09.b but using manufactured sand conforming to relevant I.S. codes in suitable proportion with river sand, based on mix design with prior approval from consultants, subject to proportion of manufactured sand not exceeding 67% of river sand.

Same as item 2.09.b but with minimum cement 288 Kg per cum + flyash in required proportion.Same as item 2.12.1 but with minimum cement 260 Kg per cum + flyash in required proportion.Same as item 2.13.1 but with minimum cement 288 Kg per cum + flyash in required proportion.Same as item 2.14.1 but with minimum cement 320 Kg per cum + flyash in required proportion.50 mm thick marble chips flooring (in-situ terrazzo flooring) rubbed and polished with different grade emery stones to achieve mirror finish as per the drawing and design, under layer 38 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) and top layer 12mm thick with marble chips of colour and sizes from 7mm to 10mm nominal size laid in white cement marble powder mix 3:1 (3 white Cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix : 3 marble chips) admixed with non-fading pigment of approved shade and make by volume including cement slurry, placing the homogenous mix in alternate panels and panels being formed with glass strips and finishing the panels with approved colour pigments. The rate shall be inclusive of mirror polishing of the panels with different emery stones including cleaning with oxalic acid or as directed by engineer in charge. (NO WAXING SHALL BE PERMITTED). The rate should also include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

55 mm thick pebbled concrete using 10-15mm rounded river pebbles of approved shades as per design, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) and 15mm thick top layer using 10-15mm rounded pebbles laid in white cement admixed with approved shade and make non-fading pigment, including cleaning with water & oxalic acid as directed by engineer in charge.

Providing & laying average 25 mm thick stone of following type of approved quality, selected and sorted for uniform colour, in floor, otta, sill, skirting, tread, riser etc., in required sizes upto 60 cm. as per design and drawings (with grooves). Kota stone to be laid over cement mortar 1:6 bedding of average 35 to 40 mm thickness with joints, pointing and making grooves as specified, including curing and cleaning upto the satisfaction of the Architect & Engineer-in-charges etc. complete. (NO WAXING WILL BE PERMITTED). The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Teak / Rainbow Sand Stone of 40mm thickness having Natural Finish.

Natural Slate Stone of 10-15mm thickness having Natural Finish of approved shade like red, peacock, rainbow, multi colour etc.Providing & laying Flat, irregular natural sand stone (Agra red, Dholpur pink etc.) pieces 25-30 mm thick, roughly 600x600 mm size of approved shade and quality, selected and sorted in floor as per design in crazy pattern (with grooves). Stone is to be laid over cement mortar 1:6 bedding of 35 to 50 mm thickness including pointing with epoxy grout of approved shade in joints, curing and cleaning upto the satisfaction of the Architect & Engineer-in-charge etc. complete. The work shall be carried out as per the approval of architect and satisfaction of engineer in charge. The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over.

Same as item 9.34.a but using manufactured sand conforming to relevant I.S. codes in suitable proportion with river sand, based on mix design with prior approval from consultants, subject to proportion of manufactured sand not exceeding 67% of river sand.

Same as item 9.34.a but with minimum cement 260 Kg per cum + flyash in required proportion.

Page 53: SPCL Offer 9(New)_03.12.09

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09 Page 53 of 53

Sr. N0. Item description Unit Quantity Rate9.41

a. Slate 10-15 mm thick, upto 600 mm size Sqm QRO 1 323b. Sqm QRO 1 945

c. Granite Sqm QRO 3 561Electrical Works:

21.1 No. QRO 2 074

Fire fighting Works:5.1 No. QRO 10 180

a. 100 mm dia 5.2

a. 100 mm dia No. QRO 8 9435.3

a. 65 mm dia No. QRO 5 2525.4 No. QRO 1 793

5.5 No. QRO 17 741

Providing & fixing dado or cladding of following type of stone on wall for all heights having specified thickness and size with grooves (10mm) in both direction, filling the grooves with epoxy grout of matching shade as per detail design and drawing. The stone shall be fixed over 12 to 15 mm thick wired finish plaster in cement mortar 1:4 (1 cement : 4 coarse sand). The stone shall be fixed in 1:1 cement mortar. The rate shall also include backing coat wired finish plaster of average 15 mm thick in cement mortar 1:4 (1 cement : 4 coarse sand). The work shall be carried out as per the cladding sample approved by Architect and engineer in charge.

Sand stone (Agra red, Dholpur pink etc.), 25-30mm thick, size upto 600mm

One fan point controlled by two, two way 6 A switches and hum free electronic type step regulator.

Providing and fixing double flanged cast iron, Sluice valve complete with C.I. body, EPDM disc seal, SS retainer ring, carbon steel disc & shaft and lever conforming to BS 5155 and suitable for PN 16 including companion flanges.

Providing and fixing double flanged cast iron type Non-return valve conforming to API 596/598 with CI body, CS plate & SS spring & suitable for 16 kg /cm2 with companion flanges.

Providing and fixing fire authority approved bronze ball valves with all fittings required.

Providing, fixing, testing and commissioning 40mm diameter drain valve.Providing, fixing, testing and commissioning 100mm diameter pot strainer.