spatial frequency cc-90sw cc-100 cc-100xp contrast ... · cv-5000pc sw cv-5000 rc for cc-90sw**...

2
SOLUTION A TOPCON EXAM Subject to change in design and/or specifications without advanced notice. In order to obtain the best results with this instrument, please be sure to review all user instructions prior to operation. IMPORTANT Specifications CC-90SW CC-100 CC-100XP Testing distance 2.9 – 6.1 m, stepsize 0.1m Viewing area W x D (mm) 473 x 265 473 x 265 Visual acuity range / steps Decimal: 0.05 to 2.0 LogMar: 1.3 to – 0.30 Snellen (m): 120 to 3 Snellen (f): 400 to 10 Monoyer: 0.5 to 2.0 VA test, compliant with ISO 8596 Landolt C VA test, compliant with ISO 8597 Letters Numbers Tumbling E VA tests 3 Children charts ETDRS Monocular R/G Clock fan Astigmatism dots Binocular tests (image separation) Schober test Worth test Colour test Inversion test Sine wave contrast test Contrast modifying test Contrast sensitivity test Separation through RED - GREEN Circulair Polarisation Duochrome balance test Cross test Cross test with fixation Zeigertest Double Zeigertest Coincidence test H&V with fixation VA Balance test Indicator Double indicator Stereo test Stereo triangle 11 Stereo valenz 20 differential stereo Vertical OXO-like Horizontal OXO-like Random dot (Topcon) Random dot (Stages) Cowen Fixation disparity test Dimensions W x H x D (mm) 560 x 358 x 56 560 x 358 x 56 LCD: contrast ratio 10.000:1 10.000:1 Weight (kg) 7,0 Kg 7,0 kg Main voltage AC 110 - 240 V; 50-60 Hz Power consumption 120 VA Accessories Calibration kit & installation software Polaroid filters for trial frame Remote controller Virtual Remote Controler on PC WiFi Dongles 2x Options Remote controller Versatile operation The Topcon CC-100 series Chart systems can be operated in various ways. Operation can be done by Remote Control or the Virtual Remote Control on a PC as stand alone, with the KB-50S controller or with the CV-5000 PC controller software in combination with Topcon’s dedicated CV-5000 automated phoropter. The CV-5000 Tablet can be used as well. This innovative and stylish solution offers a wireless operation and the CV-5000 Tablet can be used for other applications such as near tests as well. Spatial Frequency Contrast Sensitivity Test The Spatial Frequency Contrast Sensitivity Test can be customized by setting the amount of spatial frequencies and contrast levels. The result gives valuable information on the patients contrast visual acuity. Test results are displayed in a graph which is printable as well. Spatial Frequency Contrast Sensitivity test is applicable for CC-100 and CC-100XP. Item code: 5213331 / printed in Europe 05.15 CV-5000 Tablet RC CC-100 KB-50S RC on PC* CC-100XP CV-5000PC SW CV-5000 RC for CC-90SW** CC-90SW * included with CC-100 series ** included with CC-90SW Topcon Europe Medical B.V. Essebaan 11; 2908 LJ Capelle a/d IJssel; P.O. Box 145; 2900 AC Capelle a/d IJssel; The Netherlands Phone: +31-(0)10-4585077; Fax: +31-(0)10-4585045 E-mail: [email protected]; www.topcon-medical.eu Topcon Danmark Praestemarksvej 25; 4000 Roskilde, Danmark Phone: +45-46-327500; Fax: +45-46-327555 E-mail: [email protected] www.topcon.dk Topcon Scandinavia A.B. Neongatan 2; P.O. Box 25; 43151 Mölndal, Sweden Phone: +46-(0)31-7109200; Fax: +46-(0)31-7109249 E-mail: [email protected]; www.topcon.se Topcon España S.A. HEAD OFFICE; Frederic Mompou, 4; 08960 Sant Just Desvern; Barcelona, Spain Phone: +34-93-4734057; Fax: +34-93-4733932 E-mail: [email protected]; www.topcon.es Topcon Italy Viale dell’ Industria 60; 20037 Paderno Dugnano, (MI) Italy Phone: +39-02-9186671; Fax: +39-02-91081091 E-mail: [email protected]; www.topcon.it Topcon France BAT A1; 3 route de la révolte, 93206 Saint Denis Cedex Phone: +33-(0)1-49212323; Fax: +33-(0)1-49212324 E-mail: [email protected]; www.topcon-medical.fr Topcon Deutschland GmbH Hanns-Martin-Schleyer Strasse 41; D-47877 Willich, Germany Phone: (+49) 2154-885-0; Fax: (+49) 2154-885-177 E-mail: [email protected]; www.topcon-medical.de Topcon Polska Sp. z o.o. ul. Warszawska 23; 42-470 Siewierz; Poland Phone: +48-(0)32-670-50-45; Fax: +48-(0)32-671-34-05 www.topcon-polska.pl Topcon (Great Britain) Ltd. Topcon House; Kennet Side; Bone Lane; Newbury Berkshire RG14 5PX; United Kingdom Phone: +44-(0)1635-551120; Fax: +44-(0)1635-551170 E-mail: [email protected], www.topcon.co.uk Topcon Ireland Unit 276, Blanchardstown; Corporate Park 2 Ballycoolin; Dublin 15, Ireland Phone: +353-18975900; Fax: +353-18293915 E-mail: [email protected]; www.topcon.ie TOPCON EUROPE MEDICAL B.V. Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands, Phone: +31-(0)10-4585077, Fax: +31-(0)10-4585045, E-mail: [email protected], www.topcon-medical.eu CC-series Computerised Chart Systems

Upload: others

Post on 26-Jun-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

SOLUTIONA TOPCON EXAM

KR-1WWave-Front Analyzer

PERFORMANCEYOU CAN COUNT ON

Subject to change in design and/or specifications without advanced notice.

In order to obtain the best results with this instrument, please be sure to review all user instructions prior to operation.IMPORTANT

SpecificationsCC-90SW CC-100 CC-100XP

Testing distance 2.9 – 6.1 m, stepsize 0.1m

Viewing area W x D (mm) 473 x 265 473 x 265

Visual acuity range / steps Decimal: 0.05 to 2.0LogMar: 1.3 to – 0.30Snellen (m): 120 to 3Snellen (f): 400 to 10Monoyer: 0.5 to 2.0

VA test, compliant with ISO 8596 Landolt C

VA test, compliant with ISO 8597 LettersNumbersTumbling E

VA tests 3 Children chartsETDRSMonocular R/GClock fanAstigmatism dots

Binocular tests (image separation) Schober testWorth testColour testInversion test Sine wave contrast testContrast modifying testContrast sensitivity testSeparation through RED - GREENCirculair PolarisationDuochrome balance testCross testCross test with fixationZeigertestDouble Zeigertest Coincidence test H&V with fixationVA Balance testIndicatorDouble indicatorStereo testStereo triangle 11Stereo valenz 20differential stereoVertical OXO-likeHorizontal OXO-likeRandom dot (Topcon)Random dot (Stages)CowenFixation disparity test

Dimensions W x H x D (mm) 560 x 358 x 56 560 x 358 x 56

LCD: contrast ratio 10.000:1 10.000:1

Weight (kg) 7,0 Kg 7,0 kg

Main voltage AC 110 - 240 V; 50-60 Hz

Power consumption 120 VA

Accessories Calibration kit & installation softwarePolaroid filters for trial frameRemote controllerVirtual Remote Controler on PCWiFi Dongles 2x

Options Remote controller

Versatile operationThe Topcon CC-100 series Chart systems can be operated in various ways. Operation can be done by Remote Control or the Virtual Remote Control on a PC as stand alone, with the KB-50S controller or with the CV-5000 PC controller software in combination with Topcon’s dedicated CV-5000 automated phoropter. The CV-5000 Tablet can be used as well. This innovative and stylish solution offers a wireless operation and the CV-5000 Tablet can be used for other applications such as near tests as well.

Spatial Frequency Contrast Sensitivity Test

The Spatial Frequency Contrast Sensitivity Test can be customized by setting the amount of spatial frequencies and contrast levels. The result gives valuable information on the patients contrast visual acuity. Test results are displayed in a graph which is printable as well. Spatial Frequency Contrast Sensitivity test is applicable for CC-100 and CC-100XP.

Item

cod

e: 5

2133

31 /

prin

ted

in E

urop

e 05

.15CV-5000 Tablet

RC

CC-100

KB-50S

RC on PC*

CC-100XP

CV-5000PC SW

CV-5000

RC for CC-90SW**

CC-90SW

* included with CC-100 series** included with CC-90SW

Topcon Europe Medical B.V.Essebaan 11; 2908 LJ Capelle a/d IJssel; P.O. Box 145; 2900 AC Capelle a/d IJssel; The NetherlandsPhone: +31-(0)10-4585077; Fax: +31-(0)10-4585045E-mail: [email protected]; www.topcon-medical.eu

Topcon DanmarkPraestemarksvej 25; 4000 Roskilde, DanmarkPhone: +45-46-327500; Fax: +45-46-327555E-mail: [email protected] www.topcon.dk

Topcon Scandinavia A.B.Neongatan 2; P.O. Box 25; 43151 Mölndal, SwedenPhone: +46-(0)31-7109200; Fax: +46-(0)31-7109249E-mail: [email protected]; www.topcon.se

Topcon España S.A.HEAD OFFICE; Frederic Mompou, 4; 08960 Sant Just Desvern; Barcelona, SpainPhone: +34-93-4734057; Fax: +34-93-4733932E-mail: [email protected]; www.topcon.es

Topcon ItalyViale dell’ Industria 60;20037 Paderno Dugnano, (MI) ItalyPhone: +39-02-9186671; Fax: +39-02-91081091E-mail: [email protected]; www.topcon.it

Topcon FranceBAT A1; 3 route de la révolte, 93206 Saint Denis CedexPhone: +33-(0)1-49212323; Fax: +33-(0)1-49212324E-mail: [email protected]; www.topcon-medical.fr

Topcon Deutschland GmbHHanns-Martin-Schleyer Strasse 41; D-47877 Willich, GermanyPhone: (+49) 2154-885-0; Fax: (+49) 2154-885-177E-mail: [email protected]; www.topcon-medical.de

Topcon Polska Sp. z o.o.ul. Warszawska 23; 42-470 Siewierz; PolandPhone: +48-(0)32-670-50-45; Fax: +48-(0)32-671-34-05www.topcon-polska.pl

Topcon (Great Britain) Ltd.Topcon House; Kennet Side; Bone Lane; NewburyBerkshire RG14 5PX; United KingdomPhone: +44-(0)1635-551120; Fax: +44-(0)1635-551170E-mail: [email protected], www.topcon.co.uk

Topcon IrelandUnit 276, Blanchardstown; Corporate Park 2 Ballycoolin; Dublin 15, Ireland Phone: +353-18975900; Fax: +353-18293915E-mail: [email protected]; www.topcon.ie

TOPCON EUROPE MEDICAL B.V.Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands, Phone: +31-(0)10-4585077, Fax: +31-(0)10-4585045, E-mail: [email protected], www.topcon-medical.eu

Standard Option 1

Option 2 Option 3

Standard Option 1

Option 2 Option 3

CC-seriesComputerised Chart Systems

CC-90SW

CC-100

Topcon CC-90SW is a flexible chart system. You can use your own TFT monitor and pc, starting from 19”. An all-in one PC is suitable as well. The CC-90SW will be attached to your screen.

Topcon CC-90SW performs the most commonly used visual acuity tests, like Letters, Landolt C, Tumbling E, Numbers and Children charts. The White Maddox LED light supports the Maddox testing.

The CC-90SW is standard supplied with a remote controller, making the CC-90SW a low cost stand alone solution for your practice. An easy calibration kit assures the correct projection of the visual acuity test on your TFT screen.

The Topcon CC-100 is a versatile solution to present charts to patients. The high resolution 21,5” LED screen ensures clear and bright chart display. All commonly known acuity test are available, including ETDRS. The CC-100 provides image separation through red and green. Data can be sent through WiFi to PC.

» Wide range of Optotypes» White Maddox LED light source» Random function» High resolution 21,5” LED screen » Integrated PC» Image separation through red / green

» Wide range of Optotypes» White Maddox LED light source» Flexible set-up» Usable with every consumer monitor» Easy control through dedicated remote controller

Computerised Chart SytemsTopcon offers a wide range of Computerised Chart Sytems. Depending on your wishes Topcon offers a matching system. Topcon chart systems can be operated as stand alone or can be integrated in a Topcon refraction lane.

Your personal LCD test chart (led) CC-100XP

The Topcon CC-100XP with LED technology is the top model of the Chart System line. All important visual acuity tests, binocular tests, colour vision tests and contrast sensitivity tests are available.

The spatial Frequency Contrast Sensitivity is a unique feature, which provides quantitative and qualitative information about the patients contrast visual acuity.

Image separation for binocular testing is created through a specific polarisation technique which is unique for LCD test charts. This unique polarisation technique provides 100% image separation, without any “ghost image”! This is a significant improvement compared to all conventional polarised LCD chart systems currently available on the market.

White Maddox LEDThe white Maddox LED provides a small light source, extremely well fitted for Maddox testing. All conventional LCD chart systems provide the Maddox light within the LCD display itself, which is either too big or not bright enough to perform proper Maddox testing

Contrast sensitivity test reports and colour test reports can be printed using WiFi technology to a WiFi printer.

To assure proper settings of the screen contrast and brightness, the CC-100XP is making use of the latest LED screen technology.» 100% polarisation» Wide range of Optotypes» Spatial Frequency Contrast Sensitivity Test» White Maddox LED light source» MKH test sequence according to Haase

Visual acuity charts of the Topcon computerised chart systemsThe Topcon chart systems offer the most commonly used visual acuity tests ranging from Letters, Tumbling E, Landolt C and Numbers up to three different Children charts.

VA charts available in Letters

Illiterates and children charts

(5 different chart types)

Numbers Landolt CTumbling E

ETDRS chart (2)

Ghost images and different background colors in

conventional LCD chart systems

100% separation and equal background in Topcon CC-100XP

Pseudo-Isochromatic Color Vision Test

The Pseudo-Isochromatic test is based on the well-known HRR test, but providing better quantitative data on color vision deficiencies. CC-100XP displays the results in an easy to understand graph which is printable as well. Pseudo-Isochromatic Vision tests are available in CC-100 and CC-100XP.

Masking is available for horizontal (row), vertical (column) and single characters

MKH test sequence according to Haase

MKH test sequence is available in CC-100XP for functional optometry testing

Cross

Stereo triangle

Differential stereo

Indicator

Reduced stereo triangle

Random dot Topcon

Double indicator

Stereo Valence

Random dot Stages

Coincidence

Reduced Stereo Valence

Cowen

LEA charts